<p>APCO 10 13 00.20 Master Specification - MyDay (Pg. 1) Display Systems</p><p>SECTION 10 13 00.20</p><p>DISPLAYS</p><p>Date: 09/15/11 (MyDay)</p><p>PART 1 - GENERAL</p><p>** THIS SECTION INCLUDES SPECIFICATIONS FOR INTERIOR DISPLAYS CONSTRUCTED AS FABRIC COVERED BULLETIN TYPE BOARDS OR MULTIPLE COLUMN MAKER BOARDS AND CLOCK BOARDS. TYPES INCLUDED ARE WALL MOUNTED STYLES. SELECT APPROPRIATE TYPE OR TYPES BELOW. CONSULT MANUFACTURER'S CATALOG FOR OPTIONS.</p><p>1.01 SUMMARY</p><p>A. Section includes:</p><p>1. Interior non-illuminated ** surface wall mounted ** fabric covered bulletin board ** dry erase board ** clock board ** complete with components by single manufacturer at locations indicated in Schedule. 2. Component options specified below.</p><p>1.02 REFERENCES</p><p>A. Standards of the following as referenced: 1. Aluminum Association (AA). 2. American National Standards Institute (ANSI). 3. American Society for Testing and Materials (ASTM).</p><p>1.03 SYSTEM DESCRIPTION</p><p>A. MyDay is a modular system for displaying multiple types of information. Bulletin boards and combination Display, Dry Erase, Clock, Hook, Magazine Holder and Pin Board elements provided under this section are intended to include interchangeable flexible designed units utilizing replaceable panels in horizontal or vertical configurations from single manufacturer using minimum of standard components housed in aluminum. </p><p>1.04 SUBMITTALS</p><p>A. Product data: 1. Manufacturer's signed statement regarding compliance with QUALITY ASSURANCE Article. 2. Manufacturer's product literature indicating units and designs selected.</p><p>B. Installation Instructions: 1. Indicate applicable substrate mounting provided in other sections. Include requirements for anchors not furnished in this section.</p><p>1.05 QUALITY ASSURANCE </p><p>A. Manufacturer qualifications: Work required under this section from manufacturers regularly engaged in work of this magnitude and scope for minimum of five years.</p><p>B. Pre-installation conferences: Coordinate with work required in other sections for completely coordinated and smooth installation.</p><p>1.06 DELIVERY, STORAGE, AND HANDLING 10 13 00.20 APCO Master Specification - MyDay (Pg. 2) Display Systems</p><p>A. Indicated in Delivery, Storage, and Handling Section.</p><p>** USE EITHER A. ABOVE or B. and C. BELOW.</p><p>B. Acceptance at site: Coordinate delivery of work to Project site under this section for immediate installation.</p><p>C. Handling materials and equipment: Handle displays in careful manner in order not to damage or mar surfaces of displays or adjacent finish surfaces.</p><p>1.07 SEQUENCING AND SCHEDULING</p><p>A. Coordinate: 1. Installation with adjacent finish materials not destroying adjacent surfaces. 2. With other sections for cast-in or built-in anchors and mounting hardware in work accomplished in other sections.</p><p>PART 2 - PRODUCTS</p><p>2.01 MANUFACTURED UNITS</p><p>A. Acceptable product:</p><p>1. APCO USA; MyDay Display System; 388 Grant Street SE, Atlanta, Georgia, 30312, USA. Phone; (404) 688-9000 or (877) 988-2726. Fax; (404) 577-3847 www.apcosigns.com 2. Other manufacturer's products are acceptable if submitted in accord with Product Options and Substitutions section and are in strict compliance with these specified requirements. </p><p>B. Configurations, Sizes & Codes: (note: sizes shown are nominal)</p><p>1. Horizontal “MDH” Configurations: a. 16” Frame Height Configurations and Codes i. MDH1616 (16”h x 16”w) ii. MDH1632-0 (16”h x 32”w) iii. MDH1632-1 (16”h x 32”w) iv. MDH1648-00 (16”h x 48”w) v. MDH1648-10 (16”h x 48”w) vi. MDH1648-01 (16”h x 48”w) vii. MDH1648-11 (16”h x 48”w) viii. MDH1664-000 (16”h x 64”w) ix. MDH1664-100 (16”h x 64”w) x. MDH1664-010 (16”h x 64”w) xi. MDH1664-001 (16”h x 64”w) xii. MDH1664-110 (16”h x 64”w) xiii. MDH1664-011 (16”h x 64”w) xiv. MDH1664-101 (16”h x 64”w) xv. MDH1664-111 (16”h x 64”w)</p><p> b. 20” Frame Height Configurations and Codes i. MDH2016 ii. MDH2032-0 iii. MDH2032-1 iv. MDH2048-00 v. MDH2048-10 vi. MDH2048-01 vii. MDH2048-11 viii. MDH2064-000 ix. MDH2064-100 x. MDH2064-010 xi. MDH2064-001 APCO 10 13 00.20 Master Specification - MyDay (Pg. 3) Display Systems</p><p> xii. MDH2064-110 xiii. MDH2064-011 xiv. MDH2064-101 xv. MDH2064-111</p><p> c. Horizontal Display Options i. Fabric Covered Pin Board **16”h**20”h** by **16”w**32”w**48”w**64”w** ii. Rubberized Cork Pin Board x ** **16”h**20”h** by **16”w**32”w**48”w**64”w** iii. Fabric Covered Pin Board – COM (Customer Supplied Material) **16”h**20”h** by **16”w**32”w**48”w**64”w** iv. Marker Board – Masonite (Blank with White Background) **16”h**20”h** by **16”w**32”w**48”w**64”w** v. MarkerBoard – AR Acrylic (With Graphics and/or Non-White Background) **16”h**20”h** by **16”w**32”w**48”w**64”w** vi. Clock Display **16”h**20”h** by 16”w Board with **Radio Controlled Clock (#625-488)** Standard Battery Powered Quartz Clock (#625-254)**</p><p> d. Accessories i. Hanger (MDHNGR) x **1**2**3**4** ii. 2” Shelf (MDSHLF) by **16”w**32”w**48”w**64”w** iii. Magazine Holder (MDMHLDR) x **1**2**3**4** iv. Notifier Clip (MDSB30N) by **16”w**32”w**48”w**64”w**</p><p>2. Vertical “MDV” Configurations: a. 16” Frame Width Configurations i. MDV1616 ii. MDV3216 iii. MDV3216-1 iv. MDV4816-10 v. MDV4816-01 vi. MDV4816-11</p><p> b. 20” Frame Width Configurations i. MDV1620 ii. MDV3220 iii. MDV3220-1 iv. MDV4820-10 v. MDV4820-01 vi. MDV4820-11</p><p> c. Vertical Display Options i. Fabric Covered Pin Board **16”w**20”w** by **16”h**32”h** ii. Rubberized Cork Pin Board x ** **16”w**20”w** by **16”h**32”h** iii. Fabric Covered Pin Board – COM (Customer Supplied Material) **16”w**20”w** by **16”h**32”h** iv. Marker Board – Masonite (Blank with White Background) **16”w**20”w** by **16”h**32”h** v. MarkerBoard – AR Acrylic (With Graphics and/or Non-White Background) **16”w**20”w** by **16”h**32”h** vi. Clock Display **16”w**20”w** by 16”h Board with **Radio Controlled Clock (#625-488)** Standard Battery Powered Quartz Clock (#625-254)**</p><p> d. Accessories i. Hanger (MDHNGR) ii. 2” Shelf (MDSHLF) by **16”w**20”w** iii. Magazine Holder (MDMHLDR) by **16”w**20”w** 10 13 00.20 APCO Master Specification - MyDay (Pg. 4) Display Systems</p><p> iv. Notifier Clip (MDSB30N) by **16”w**32”w**</p><p>C. Design units with selected components below. </p><p>2.02 COMPONENTS/FINISHES</p><p>A. Housing/Frame: 1. Custom engineered aluminum extruded profiles with Header and Base designed with special channel and lifter system preventing vandal access. Normal: ** ASTM B221-90 extruded aluminum Alloy 6063-T6, AA **</p><p>2. Header and Base frame shapes: ** Radius ** Square **</p><p>3. Frame color: Selected by Architect from manufacturer's standard finishes. a. Radius Header Base color: ** Natural Satin Anodized ** 02 Black** 43 Putty** b. Vertical Side Rail color: ** Natural Satin Anodized** 02 Black** 43 Putty** </p><p>4. Fabric Color: Selected by Architect from manufacturer’s standard fabrics: a. ** Sulphur Grey** Mintless ** Customer provided fabric **</p><p>5. Rubberized Cork Pin Board Color: Selected by Architect from manufacturer’s standard colors: a. ** Light Grey A47 ** Natural **</p><p>6. Clock Board Color: Selected by Architect from manufacturer’s standard colors: a. ** Satin Anodized Aluminum**A02 Black**A43 Putty** Simulated Wood Grain **</p><p>7. Marker Board Background Color & Graphics: Colors selected by Architect from manufacturer’s standards: a. ** White ** Other ** Background Color b. **Subsurface silkscreen printed graphics**Subsurface digitally printed graphics**</p><p>8. Furnish each unit with manufacturer’s standard tool (SCT) for removal of tamper resistant panels and complete installation guide. Include Pins, Markers, Cleaner, Eraser, etc. as specified by architect using manufacturer’s codes and descriptions.</p><p>2.03 FABRICATION</p><p>A. Shop assembly: 1. Fabricate units to configurations indicated on reviewed shop drawings. 2. Furnish copy required on reviewed shop drawings.</p><p>PART 3 - EXECUTION</p><p>3.01 EXAMINATION</p><p>A. Verification of conditions: ** Indicated in Coordination Section. ** OR ** 1. Examine areas to receive displays; verify for correct location of cast-in anchors installed under other sections. 2. Notify Architect in writing of unacceptable substrate or improper location of anchors. 3. Beginning work indicates acceptance of substrate. Subsequent modifications to substrate or display becomes this section's complete responsibility.</p><p>3.02 INSTALLATION</p><p>A. Install display in locations indicated in accord with reviewed shop drawings. Square, plumb, and level units. APCO 10 13 00.20 Master Specification - MyDay (Pg. 5) Display Systems</p><p>3.03 CLEANING</p><p>A. Clean exposed surfaces not more than 48 hours prior to Date of Substantial Completion in accord with manufacturer's instructions.</p><p>END OF SECTION 10 13 00.20</p>
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages5 Page
-
File Size-