Powerpcb Training Manual, Your First Design

Powerpcb Training Manual, Your First Design

<p> Appendix D</p><p>Sample .DO File #1 bestsave on C:\padspwr\files\xx.bst = Save only if this interation is better than the last one autosave on C:\padspwr\files\xx.ato = Save after every interation status_file C:\padspwr\files\xx.sts = Create a file of all the routing activity unselect all vias = Do not use any VIAS at this time unit mil = Set the routing Units to MIL’s grid via 8.333 = Set the Grid that the VIA’s will be routed on grid wire 8.333 = Set the Routing Grid for the traces protect all wires = Fix all Hand Routed traces direction 1 horizontal = Route traces on the Top Layer Horizontally direction 2 vertical = Route traces on Inner Layer 2 Vertically direction 3 horizontal = Route traces on Inner Layer 3 Horizontally direction 4 vertical = Route traces on Inner Layer 4 Vertically direction 5 horizontal = Route traces on Inner Layer 5 Horizontally direction 6 vertical = Route traces on Inner Layer 6 Vertically direction 7 horizontal = Route traces on Inner Layer 7 Horizontally direction 8 vertical = Route traces on the Bottom Layer Vertically define (class clocks clk* 60mhz) = Create a CLASS called CLOCKS that contains nets CLK’s & 60MHZ select via STANDARDVIA = Route traces using the STANDARDVIA bus diagonal = Route the Memory Section or pin pairs that have the same X or Y Coor fanout 5 (pin_type power) = Insert the GND & VCC VIA’s on all SMT devices, using 5 interations (via_share on) = If two pins in the same net are next to each other, Share the same VIA (max_len 100) = Do not let the VIA Fanout stub length be longer than .100” (direction out) = Set the VIA location to OUTSIDE the Landpattern protect net GND VCC = Fix all GND & VCC Fanout’s and prevent the router from moving them select via MICROVIA = Change the routing VIA to MICROVIA fanout 5 (pin_type signal) = Insert the Signal VIA’s on all SMT devices, using 5 interations (via_share on) = If two pins in the same net are next to each other, Share the same VIA (direction in_out) = Set the VIA location to INSIDE or OUTSIDE the Landpattern select class clocks = Highlight the Nets in the Class called CLOCKS select layer L1 L8 = Turn on routing layers 1 & 8. (Turn off all other layers) order daisy selected = Set the routing algorithm to route in a Daisy Chain fashion route 10 = Route the Class “CLOCKS’ 10 Interations clean 4 = Clean up the CLOCK line routing critic = Remove unnecessary Bumps in the routes select all layers = Highlight all 8 layers (Turn on all 8 Layers) select all nets = Highlight all Nets (Turn on all the Net’s) route 25 = Route the remaining unrouted Nets 25 Interations clean 4 = Clean up all signal routes on all layers critic = Remove unnecessary Bumps in the routes spread = Spread the traces out to allow more space between the traces write wire C:\padspwr\files\xx.wir = Create a file of the routes before the corners are chamfered unprotect all wires = Unfix all Hand Routes and all Power traces recorner diagonal = Remove all 90 degree routing and Chamfer all corners miter (pin 50)(slant 100)(bend 1000 50) = Remove all 90 degree routing and Chamfer all corners write routes C:\padspwr\files\xx.rte = Create a route file of all the traces after Chamfering quit = Leave the auto-router and return to PowerPCB</p><p>Rev. 246 ©2002 ACUCAD ~ 1011 Glacier Pkwy, Algonquin, IL 60102-5004 Voice (847) 854-6052 FAX (847) 854-6053 D.1 Appendix D</p><p>Sample .DO File #2 bestsave on \padspwr\files\xx.bst = Save only if this interation is better than the last one autosave on \padspwr\files\xx.ato = Save after every interation status_file C:\padspwr\files\xx.sts = Create a file of all the routing activity unselect all vias = Do not use any VIAS at this time unit mil = Set the routing Units to MIL’s grid via 8.333 = Set the Grid that the VIA’s will be routed on grid wire 8.333 = Set the Routing Grid for the traces protect all wires = Fix all Hand Routed traces direction 1 horizontal = Route traces on the Top Layer Horizontally direction 2 vertical = Route traces on Inner Layer 2 Vertically direction 3 horizontal = Route traces on Inner Layer 3 Horizontally direction 4 vertical = Route traces on Inner Layer 4 Vertically direction 5 horizontal = Route traces on Inner Layer 5 Horizontally direction 6 vertical = Route traces on Inner Layer 6 Vertically direction 7 horizontal = Route traces on Inner Layer 7 Horizontally direction 8 vertical = Route traces on the Bottom Layer Vertically select via MICROVIA = Route traces using the MICROVIA smart_route = Includes: Bus Diagonal, Fanout 5, Route 25, Clean 4 testpoint (use_via TESTVIA)(center_center 100) = Add Testpoints critic = Remove unnecessary Bumps in the routes spread = Spread the traces out to allow more space between the traces report testpoint C:\padspwr\files\xx.rpt = Test Point Report report unconnect C:\padspwr\files\xx.non = Unconnected route report write wire C:\padspwr\files\xx.wir = Create a file of the routes before the corners are chamfered unprotect all wires = Unfix all Hand Routes and all Power traces recorner diagonal = Remove all 90 degree routing and Chamfer all corners miter (pin 50)(slant 100)(bend 1000 50) = Remove all 90 degree routing and Chamfer all corners write routes C:\padspwr\files\xx.rte = Create a route file of all the traces after Chamfering quit = Leave the auto-router and return to PowerPCB</p><p>D.2 Rev. 246 ©2002 ACUCAD ~ 1011 Glacier Pkwy, Algonquin, IL 60102-5004 Voice (847) 854-6052 FAX (847) 854-6053</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us