Aubt Qualification Test

Aubt Qualification Test

<p>AUBT PRACTICAL EXAMINATION WORKSHEET</p><p>Name:______</p><p>Base Metal Sample</p><p>1. Detect any backscatter signals in sample provided. Base Metal Sample #: </p><p>2. Identify the pattern type of any backscatter signals and apply the appropriate procedure. </p><p>Pattern Type: I II III IV </p><p>3. Store and recall to a document (or print) the backscatter signals. Images required:  10 MHz backscatter of Reference block: Image#: ______ 10 MHz backscatter of Indication from base metal sample: Image#: ______ 5 MHz backscatter of Indication displayed appropriately: Image#: ______ Spectrum Analysis of both Reference and Indication: Image#: ______ Velocity Ratio Method 1 - Show images of 1st and 2nd backwall signals from both L-wave and S-wave with cursors visible: Image#: ______ Velocity Ratio Method 2 – Show image of backwall signal (or interface) with absolute curser visible from both L-wave and S-wave: Image#: ______ Spatial Averaging of Indication: Image#: ______ Spatial Averaging of Reference block signal: Image#: ______</p><p>4. Complete the information requested for all sections below. Then, circle methods used for Analysis according to the appropriate procedure. A. 10 MHz Backscatter: Image#: _____ B. 5 MHz Backscatter: Image#: ______C. Spectrum Analysis a. Attenuation increase with frequency? Yes __ No _ b. If Yes, Attenuation at 10 MHz: dB Attenuation at 5 MHz: dB D. Velocity Ratio:  Method 1: a. Base Metal Sample L-wave (µs): b. Base Metal Sample S-wave (µs): c. Velocity Ratio: ______</p><p> Method 2: d. Cal Block Delta t1 L-wave (µs): e. Cal Block Delta t2 L-wave (µs): f. Delay (L-wave): ______g. Cal Block Delta t1 S-wave (µs): h. Cal Block Delta t2 S-wave (µs): i. Delay (S-wave): ______</p><p> j. Base Metal Sample uncorrected L-Wave (µs): ______k. Base Metal Sample uncorrected S-Wave(µs): ______l. Velocity Ratio (corrected): ______E. Spacial Avaraging</p><p>Base Metal Flaws Detected: Yes No ___ Circle Flaw Type(s) Detected:  HTHA, Laminations, Inclusions Base Metal HTHA Detected: Yes No ____ Height of HTHA if Detected: ______</p><p>Weld HAZ Samples</p><p>1. Detect any weld HAZ indications. 2. Use ABSA procedure to make the correct call. 3. Store and recall (or print) all relevant supporting data. Images required:  A-Scan with wedge delay and ID cursors set a. Wedge Delay in µs: ______b. Sample Thickness in µs: ______c. Sample Thickness in inches: ______Sizingd. ID ConventionCursor Value in µs: ______ Spectrum0 analysis of reference and suspect signal Cross section Flaws Detected: Yes No ___ Circle Flaw Type(s) Detected:Depth</p><p> HTHA, ID Crack, Lack of Penetration ( LOP ), Lack of ThicknessFusion ( LOF ), Porosity, Slag Height Weld/HAZ HTHA Detected: Yes No ___ Flaw Size: Start Length a. Start location: ______b. Length: ______c. Height: ______d. Depth: ______</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us