050614001 M48 Userguide.Indd

050614001 M48 Userguide.Indd

M-48 SuperMask® User Guide Document #050614001 Document P/N 100-800 SuperMask, Kirby Morgan, DSI, Diving Systems International, EXO, SuperFlow and DECA are all registered trademarks of Kirby Morgan Dive Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is not permitted. The two dimensional images (such as photographs and illustrations) of our products are © copyrighted and trademarks of Kirby Morgan Dive Systems, Inc. The three dimensional forms of our products are trademark/trade dress protected. © Copyright 2005 Kirby Morgan Dive Systems, Inc. All rights reserved. This manual is made available for the express use of owner of this Kirby Morgan product. No part of this manual may be reproduced, stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc. M-48 SuperMask User Guide WARRANTY INFORMATION Kirby Morgan Dive Systems, Inc. (KMDSI) warrants every new mask, hel- met, or KMAC Air Control System to be free from defects in workmanship for a period of ninety (90) days from date of purchase. This warranty covers all metal, fiberglass, and plastic parts. This warranty does NOT cover rub- ber parts, communications components, or headliners. In addition, due to the electrolytic nature of underwater cutting and welding, chrome plating cannot be warranted when the diver engages in these activities. Should any part become defective, contact the nearest authorized KMDSI dealer. If there is no dealer in your area, contact KMDSI directly at (805) 928-7772. You must have a return authorization from KMDSI prior to the return of any item, Upon approval from KMDSI, return the defective part, freight prepaid, to the KMDSI plant. The part will be repaired or replaced at no charge as deemed necessary by KMDSI. This warranty becomes null and void if: 1) The product is not registered with KMDSI within ten (10) days of purchase. 2) The product has not been properly serviced and/or maintained accord- ing to the appropriate KMDSI manual. In addition, the user is responsible to ensure that all product updates as recommended by KMDSI have been performed. 3) Unauthorized modifications have been made to the product. 4) The product has been abused or subjected to conditions which are unusual or exceed the product’s intended service. NOTE: Be sure to complete the enclosed warranty card and return it to KMDSI immediately. No warranty claims will be honored without a satis- factorily completed warranty card on file at KMDSI. 2 © 2005 KMDSI. All rights reserved. Document #050614001 M-48 SuperMask User Guide Table of Contents Definitions of Signal Words Used in this Guide 5 Introduction 6 Components of the M-48 SuperMask 9 Using the M-48 SuperMask with Open Circuit Scuba 9 Surface-Supplied Open Circuit 10 Minimum Equipment for Surface-Supplied Diving 11 Demand Regulator Adjustment / Surface-supplied 11 Regulator Hose 12 European Conformance 12 Mounting Open Circuit Regulators 12 Tools and Components Needed for Installation of Regulator 15 Pre-Dive Inspection with Open-Circuit Demand Regulator 19 Cleaning the Face Port and Interior Surfaces 20 Donning the SuperMask 20 Connecting the Pod to the Mask 22 Alternate Method of Connecting the Pod to the Mask 23 Diving with a Hood 24 Water Entry 24 Removing / Replacing Pod While Underwater 24 Alternate Method of Removing/Replacing Pod Underwater 24 Mask / Pod Dewatering 25 Releasing the Pod 26 Removing the Mask 26 Quick-Release Method of Mask Removal 26 Alternate Method of Mask Removal 26 Post Dive Procedures 27 Head Harness Removal and Installation 28 Removal of Harness from Mask Frame 28 Installation of Harness on Mask Frame 28 Communications with the M-48 SuperMask® 29 Installing a Communications Port Plug 29 Demand Regulators 30 Accessories for the M-48 SuperMask 30 Non-Stretch Harness P/N 805-030• 30 Communications Port Plug P/N 820-155 30 Mask Bag P/N 800-904 31 Inlet Swivel P/N 305-017 31 © 2005 KMDSI. All rights reserved. Document #050614001 3 M-48 SuperMask User Guide Table of Contents Manifold Block 31 Over-Pressure Relief Valve 31 SCUBA Pod 32 NATO Rebreather Pod PN# 805-080 32 Mask Variations 33 Exploded View Drawing 34 4 © 2005 KMDSI. All rights reserved. Document #050614001 M-48 SuperMask User Guide Definitions of Signal Words Used in this Guide Throughout this manual we will use certain words to call your attention to conditions, practices or techniques that may directly affect your safety. Pay particular attention to information introduced by the following signal words: DANGER This word indicates an imminently hazardous situation, which if not avoided, will result in death or serious injury. WARNING This word indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION This word indicates a potentially hazardous situation which may result in personal injury or damage to equipment. It may also be used to alert against unsafe practices. This Operation Manual contains important safety information and should always be available to those personnel operating this equipment. Read, understand, and retain all instructions before operating this equipment to prevent injury or equipment damage. If you sell or loan this equipment to another person, be sure that this manual accompanies the gear when you transfer possession to them. © 2005 KMDSI. All rights reserved. Document #050614001 5 M-48 SuperMask User Guide Introduction Congratulations for choosing the Kirby Morgan SuperMask®. The SuperMask represents years of development and testing. Development of this mask could not have been possible without the help of the diving com- munity as a whole. The original goal was to develop a modular full-face mask that could offer greater comfort and safety to divers using self-contained breathing apparatus. When the mask is used with a rebreather, it is normally used with a DSV (Dive Surface Valve), which you may also hear referred to as the rebreather’s “mouthpiece.” Dive Surface Valves are mechanisms that contain the shut off valve that connects the inlet and exhaust hoses on a rebreather. The mouthpiece for the diver normally connects to the DSV using a cable tie. The mouthpiece mounting tube is where the DSV interfaces with the M-48 mouthpiece pod. The SuperMask, was designed for use with rebreathers, as well as open circuit SCUBA, and lightweight umbilical supply. The SuperMask has been tested and certified by Dive Lab Inc. Configuration in both open and closed circuit mode have been tested and approved for use by U.S. military organizations KMDSI will continue to develop the mask as well as additional pods and accessories. Users should routinely check the KMDSI web page for additional information. Questions on the use and care of this mask should be addressed to Kirby Morgan Dive Systems Inc. Telephone 805-928-7772 or e-mail at www.kirbymorgan.com or Dive Lab Inc, Telephone 850-235- 2715 or e-mail at www.divelab.com. DANGER Kirby Morgan Dive Systems, Inc., cannot guaran- tee the diver protection from contaminants when using the SuperMask in waters that are biological- ly, chemically or radioactively polluted. Radioac- tive, chemical, and biological contaminants can cause serious, permanent bodily harm or death to the user. While the SuperMask can minimize and help re- duce the risks associated with the exposure to certain waterborne chemical and biological con- tamination, it cannot protect the user in all situa- tions or against all contaminants. 6 © 2005 KMDSI. All rights reserved. Document #050614001 M-48 SuperMask User Guide WARNING Not all SCUBA regulators or rebreather DSV’s (mouthpiec- es) will fit the M-48 mouth pod. The size of the mouthpiece mounting tube as well as the placement and size of the ex- haust tee can affect the mounting and proper functioning of the mouthpiece and folding action on the pod bellows. Additionally, it is extremely important that the demand reg- ulator or DSV being fitted does not have any sharp edges that could cut the pod skirt or mouthpiece orifice. The SCUBA regulator or DSV must not interfere with the fit of the mask, and all components must be fully functional. Do not use any component with the mask or pod if the com- ponent or mask functions are compromised in any way. WARNING Use only mouthpieces with the appropriate dimensions and characteristics for the M-48 mask pod and the breath- ing apparatus you have selected. Use of other mouthpieces may cause an insecure fit which could lead to separation of the mouthpiece from the pod, resulting in a flooded pod and drowning. WARNING Diving this mask in water containing concentrations of pe- troleum based chemicals could cause degradation of the components of the mask. Clean the mask using only a so- lution of one (1) tablespoon of a mild hand dish washing detergent, such as Joy ™ or Palmolive ™, to one gallon of water. WARNING Cold Water Diving (water Temperatures below 450F or 100C) requires specialized training and equipment. Do not at- tempt diving in cold water unless you are properly trained and equipped for this type of specialized diving. © 2005 KMDSI. All rights reserved. Document #050614001 7 M-48 SuperMask User Guide WARNING The SuperMask is NOT equipped with a one-way valve (non-return valve) for surface-supplied diving. When using the mask for surface-supplied diving it must be used with the KMDSI manifold block KMDSI PN# 300-150 or 300-155 and a suitable harness and emergency gas supply system. Without the non-return valve, the diver could be subject to a “squeeze” if the umbilical supply is severed.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    36 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us