Ryerson University and University of Toronto Team Summary

Ryerson University and University of Toronto Team Summary

Future Cities Collective LaneZero Ryerson University/University of Toronto Attached Housing Project Summary Major cities like Toronto are struggling to simultaneously densify while maintaining a sense of community. The sustainable future of our cities depends on finding new ways to inhabit existing infrastructure. LaneZero seamlessly integrates into currently thriving neighborhoods as an on-grade, net-zero energy laneway home. Relevance of Project to the Goals of the Competition In downtown Toronto, low density detached residential neighborhoods contain more than 250 linear kilometers of publicly owned laneways. This underutilized space sitting on valuable land provides a unique opportunity for unobtrusive densification. Future Cities Collective exemplifies possible laneway housing opportunities in Toronto, promoting the efficient use of public and private property in the city. Design Strategy and Key Points In order for LaneZero to achieve net-zero site energy, the design strategies employed follow a three-tiered design approach (1) Minimize conditioning needs through envelope, geometry, mass and orientation, (2) Passive conditioning strategies through natural ventilation, solar heat gains and daylighting, (3) Supplemental active conditioning through an efficient conditioning system. LaneZero brings life to laneways through comfortable, efficient housing, intended to make laneway homes a desirable and sustainable way to live. Project Data Technical Specifications o Toronto, ON, Canada (43.6 N, 79.4 W) o Exterior Wall Thermal Performance = 2 o ASHRAE Climate Zone 5A 40 ft -F-hr/Btu 2 o 930 ft o Foundation Thermal Performance = 2 o 1 Bedroom, 1 Bathroom, 2 Storeys 35 ft -F-hr/Btu o Energy Use Intensity (EUI) = o Roof Thermal Performance = 2 2 o 26 kBtu/ft /yr/unit 67 ft -F-hr/Btu 2 o HERs Index Without PV = 51, o Window U-Value = 0.14 Btu/ft -F-hr - With PV = 11 0.17 Btu/ft2-F-hr o Estimated Monthly Energy Cost = - o Window SHGC = 0.3 $65.00 USD (Profit) o HVAC specifications = • Energy Recovery Ventilator SRE 0.88, TRE 0.65 • SEER 13 (cooling), HSPF 11 (heating), EF 2.4 (DHW) .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us