Section 8A: Technical Specifications Table

Section 8A: Technical Specifications Table

SECTION 8A: TECHNICAL SPECIFICATIONS TABLE OF CONTENTS SECTION NUMBER TITLE DIVISION 1 GENERAL REQUIREMENTS 01001 Standard Drawings, Standard Specifications and Approved Materials List 01002 Contractor’s Insurance Certification and Pollution Liability Insurance 01005 Coordination with Design Engineer and Agency 01010 Summary of Work 01025 Measurement and Payment 01039 Coordination and Meetings 01043 Coordination with Agency’s Operations 01047 Connections to Existing Facilities 01060 Permits and Other Regulatory Requirements 01090 Reference Standards 01170 Special Technical Provisions 01300 Record Drawings and Submittals 01310 Construction Progress Schedules 01370 Schedule of Values 01380 Pre-Construction Video Recording and Photographs 01400 Quality Control 01410 Testing Laboratory Services 01500 Construction Facilities and Temporary Controls 01545 Protection of Work and Property 01570 Traffic Regulations 01600 Materials and Equipment 01630 Product Options and Substitutions 01700 Project Closeout 01710 Clean-up 01734 Operating and Maintenance Information 01760 Spare Parts and Maintenance Materials DIVISION 2 SITEWORK 02010 Subsurface Investigation 02050 Demolition and Removal 02055 Removal and Disposal of Polychlorinated Biphenyls (PCBs) 02130 Removal and Resurfacing of Pavement 02160 Excavation Support Systems 02200 Earthwork CITY OF OCEANSIDE TOC - 1 HENIE HILLS & J.P. STEIGER RESERVOIR REPAIRS SPECIFICATION TABLE OF CONTENTS 908754600712 October 2020 TABLE OF CONTENTS (Continued) SECTION NUMBER TITLE 02205 Existing Utilities 02222 Protecting Existing Underground Utilities 02223 Trenching, Backfilling and Compacting 02270 Temporary Soil Erosion and Sediment Control 02433 Watertight Reinforced Concrete Pipe 02743 Asphalt Concrete Pavement DIVISION 3 CONCRETE 03200 Reinforcement Steel 03230 Earthquake Cables 03251 Expansion and Construction Joints 03255 Tank Wall, Base and Top Joint 03300 Cast-in-Place Concrete 03314 Retrofit of Strand-Wound, Prestressed Concrete Reservoir 03315 Grout 03480 Precast Concrete Specialties 03740 Epoxy Adhesive Injection of Cracks in Concrete Members 03800 Leakage Testing of Reservoir 03930 Concrete Rehabilitation DIVISION 4 MASONRY 04232 Reinforced Concrete Block Masonry DIVISION 5 METALS 05220 Concrete Bolts 05500 Miscellaneous Metals DIVISION 6 WOOD AND PLASTICS (NOT USED) DIVISION 7 THERMAL AND MOISTURE PROTECTION 07110 Sheet Membrane Waterproofing DIVISION 8 DOORS AND WINDOWS (NOT USED) DIVISION 9 FINISHES 09800 Painting and Coating 09811 Fusion-Bonded Epoxy Coating 09905 Petroleum Wax Tape Coating CITY OF OCEANSIDE TOC - 2 HENIE HILLS & J.P. STEIGER RESERVOIR REPAIRS SPECIFICATION TABLE OF CONTENTS 908754600712 October 2020 TABLE OF CONTENTS (Continued) SECTION NUMBER TITLE 09954 Polyethylene Sheet or Tube Encasement DIVISION 10 SPECIALTIES (NOT USED) DIVISION 11 EQUIPMENT (NOT USED) DIVISION 12 FURNISHINGS (NOT USED) DIVISION 13 SPECIAL CONSTRUCTION 13110 Cathodic Protection DIVISION 14 CONVEYING SYSTEMS (NOT USED) DIVISION 15 MECHANICAL 15000 General Piping Systems and Appurtenances 15041 Disinfection of Reservoirs 15057 Copper Tubing, Brass and Bronze Pipe Fittings 15061 Steel Piping 15062 Wall Pipes, Seep Rings, and Penetrations 15090 Pipe Supports 15100 Valves – General 15102 Resilient Wedge Gate Valves 15103 Resilient-Seated Butterfly Valves 15104 Miscellaneous Valves 2 Inches and Smaller 15120 Control Valves 15121 Fiberglass Reinforced Cured-in-Place Pipe (CIPP) 15292 Polyvinyl Chloride (PVC) Pressure Pipe 15300 Tracer Wire DIVISION 16 ELECTRICAL – 16050 Electrical General Requirements 16055 Overcurrent Protective Device Coordination 16060 Grounding and Bonding 16075 Electrical Identification 16080 Electrical Testing 16120 Conductors and Cables 16130 Raceways and Boxes 16140 Wiring Devices CITY OF OCEANSIDE TOC - 3 HENIE HILLS & J.P. STEIGER RESERVOIR REPAIRS SPECIFICATION TABLE OF CONTENTS 908754600712 October 2020 TABLE OF CONTENTS (Continued) SECTION NUMBER TITLE 16442 Panelboards 16511 Interior Lighting DIVISION 17 INSTRUMENTATION 17010 Instrumentation and Controls – General Requirements 17020 Magnetic Flowmeter 17050 Pressure Measuring Devices APPENDICES: Appendix A Referenced Standard Drawings Appendix B Lead-Based Paint Testing Report (Prepared by Aurora Industrial Hygiene, October 12, 2018) Appendix C Henie Hills Temporary Service Plan Figures 1 and 2 CITY OF OCEANSIDE TOC - 4 HENIE HILLS & J.P. STEIGER RESERVOIR REPAIRS SPECIFICATION TABLE OF CONTENTS 908754600712 October 2020 SECTION 01001 – STANDARD DRAWINGS, STANDARD SPECIFICATIONS AND APPROVED MATERIALS LIST PART 1 – GENERAL 1.1 STANDARD SPECIFICATIONS AND STANDARD DRAWINGS A. Standard Specifications, Standard Drawings, Procedures, and Approved Materials Lists shall be as described in these specifications and the City of Oceanside Engineers Design and Processing Manual (Engineers Manual) and the City of Oceanside Water Utilities Department Water, Sewer, and Recycled Water Design and Construction Manual (Water Utilities Manual). Where the Engineers Manual and the Water Utilities Manual reference the same item, material, procedure, or specification, the Water Utilities Manual shall take precedence. B. The Water Utilities Manual can be found at http://www.ci.oceanside.ca.us/gov/water/admin/manual.asp. C. The Engineers Manual can be found at: http://www.ci.oceanside.ca.us/gov/dev/eng/edpmanual.asp. 1.2 REFERENCE STANDARDS A. Standards listed as “Reference Standards” in the various sections of these contract documents are hereby incorporated into this specification by reference. B. Reference documents shall include all revisions, amendments, supplements or addenda issued on or before the date of advertising for bids. C. The City of Oceanside Standard Specifications and Standard Drawings are incorporated into these contract documents by their reference herein and will be enforced unless superseded by the project specifications or specific details of the contract documents. 1.3 APPROVED MATERIALS LIST A. All the material used on this project, shall be in accordance with items listed in these specifications or as indicated in the Engineers Manual and Water Utilities Manual. The use of the following materials shall refer to the Water Utilities Manual: Fire Hydrants; Blow-off Valves; Air Release Valves; Pipe, Fitting, Valve, and Nut and Bolt Material and Protection; Hydraulic Valves; Water Services to House and Commercial Connections; Service Saddles; Ductile Iron Pipe Water Mains; Polyvinyl Chloride Pipe Water Mains; Bedding and Backfill; Valves under 14”; Butterfly Valves; Standard Vault; Vault Lids; Valve Box, Cover, and Can; Valve Stem Extension; Ductile Iron Fittings; Flanges; and Flange Gaskets. All other materials are to be indicated in the Engineers Manual. Where materials CITY OF OCEANSIDE 01001 - 1 HENIE HILLS & J.P. STEIGER RESERVOIR REPAIRS STANDARD DRAWINGS, STANDARD 908754600712 SPECIFICATIONS AND APPROVED MATERIALS LIST October 2020 SECTION 01001 – STANDARD DRAWINGS, STANDARD SPECIFICATIONS AND APPROVED MATERIALS LIST specified in the Engineers Manual conflict with materials specified in the Water Utilities Manual, the Water Utilities Manual shall take precedence. B. Materials not listed in these specifications must be submitted for the AGENCY’S approval and must be accepted for use on this project prior to contract award. PART 2 – MATERIALS (NOT USED) PART 3 – EXECUTION (NOT USED) **END OF SECTION** CITY OF OCEANSIDE 01001 - 2 HENIE HILLS & J.P. STEIGER RESERVOIR REPAIRS STANDARD DRAWINGS, STANDARD 908754600712 SPECIFICATIONS AND APPROVED MATERIALS LIST October 2020 SECTION 01002 – CONTRACTOR’S INSURANCE CERTIFICATION & POLLUTION LIABILITY INSURANCE PART 1 – GENERAL 1.1 INSURANCE AND INDEMNIFICATION The CONTRACTOR, by entering into a contract with the City of Oceanside for the HENIE HILLS AND JOHN PAUL STEIGER RESERVOIR REPAIRS Project, certifies and guarantees to the AGENCY that the insurance which the CONTRACTOR furnishes for the contract will provide the following: The CONTRACTOR shall hold harmless, indemnify and defend City of Oceanside, its consultants, and each of their officers, agents and employees from any and all liability, claims, losses or damage arising out of or alleged to rise from the CONTRACTOR’s negligence in the performance of the Work described in the construction contract documents, but not including liability that may be due to the sole negligence of the City of Oceanside, its consultants, or their officers, agents and employees. Furthermore, the CONTRACTOR shall provide comprehensive/commercial general liability insurance, including completed operations and contractual liability, with the latter coverage sufficient to insure the CONTRACTOR’s indemnity, as above required; and, such insurance will include City of Oceanside, its consultants, and each of their officers, agents and employees as additional insureds. 1.2 POLLUTION LIABILITY INSURANCE The CONTRACTOR shall acquire this coverage for work at issue under this Contract, which involves potential pollution risk to the environment or losses caused by pollution conditions (including asbestos) that may arise from the operations of the CONTRACTOR described in the CONTRACTOR’s scope of services. Policy shall cover the CONTRACTOR’s completed operations. Coverage shall apply to sudden and gradual pollution conditions resulting from the escape or release of odors, fumes, acids, alkalis, wastewater, or gases, natural gas, waste materials, or other irritants, contaminants, or pollutants (including lead). The coverage shall be obtained through

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    534 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us