Initial Environmental Examination Document stage: Updated Project Number: 43253-027 March 2021 India: Karnataka Integrated Urban Water Management Investment Program (Tranche 2) – Strengthening Distribution System for Implementing 24x7 Water Supply to Mangalore City Corporation Package No: 02MNG01 Part 1 of 2 (pages 1-208) Prepared by Karnataka Urban Infrastructure Development and Finance Corporation, Government of Karnataka for the Asian Development Bank. This is an updated version of the draft originally posted in May 2018 available on https://www.adb.org/projects/documents/ind-43253-027-iee-1 CURRENCY EQUIVALENTS (as of 11 March 2021) Currency unit –Indian rupee (₹) ₹1.00=$0.035 $1.00=₹74.28 ABBREVIATIONS ADB : Asian Development Bank ASI : Archaeological Survey of India CFE : Consent for establishment CFO : Consent for operation CPCB : Central Pollution Control Board DPR : Detailed project report EHS : Environmental, health and safety EIA : Environmental impact assessment EMP : Environmental management plan GLSR : Ground level service reservoir GRC : Grievance Redress Committee GRM : Grievance redress mechanism HDPE : High density polyethylene HSC : House service connection H&S : Health and safety IEE : Initial environmental examination IFC : International Finance Corporation KIUWMIP : Karnataka Integrated Urban Water Management Investment Program KSPCB : Karnataka State Pollution Control Board KUIDFC : Karnataka Urban Infrastructure Development and Finance Corporation MCC : Mangalore City Corporation NGO : Nongovernment organization OHS : Occupation health and safety OHT : Overhead tank PIU : Program implementation unit PMDCSC : Project management, design, construction and supervision consultant PMU : Program management unit REA : Rapid environmental assessment RPMU : Regional program management unit SPS : Safeguard Policy Statement ULB : Urban local body WTP : Water treatment plant WEIGHTS AND MEASURES m3 - cubic meter dia - diameter kl - kiloliter km - kilometer kmph - kilometers per hour lpcd - liters per capita per day lps liter per second m - meter mm - milliliter MCM - million cubic meters MLD - million liters per day m2 - square meter km2 - square kilometer NOTE In this report, "$" refers to United States dollars. This initial environmental examination report is a document of the borrower. The views expressed herein do not necessarily represent those of ADB's Board of Directors, management, or staff, and may be preliminary in nature. Your attention is directed to the ‘terms of use’ section on ADB’s website. In preparing any country program or strategy, financing any project, or by making any designation of or reference to a particular territory or geographic area in this document, the Asian Development Bank does not intend to make any judgments as to the legal or other status of any territory or area. CONTENTS EXECUTIVE SUMMARY 1 I. INTRODUCTION 1 A. Background 1 B. Purpose of this IEE Report 2 C. Report structure 3 II. DESCRIPTION OF THE PROJECT COMPONENTS 4 A. Project Area 4 B. Existing water supply system 4 C. Components of the proposed sub project 10 D. Implementation Schedule 29 III. POLICY AND LEGAL FRAMEWORK 41 A. ADB Safeguard Policy Statement, 2009 41 B. Government Law and Policies 43 IV. DESCRIPTION OF THE ENVIRONMENT 48 A. Introduction 48 B. Physical Environment 48 C. Ecological Resources 51 D. Economic Development 51 E. Socio Cultural Resources 53 F. Environmental Settings Subproject Component Sites 55 V. SCREENING OF POTENTIAL ENVIRONMENTAL IMPACTS AND MITIGATION MEASURES 66 A. Source Sustainability 67 B. Due Diligence of Government-Funded Components 67 C. Pre-Construction Impact 69 D. Design Impact 72 E. Construction Impact 72 F. Operational and Maintenance Impacts 83 G. Cumulative Impacts 83 VI. Public Consultation and information Disclosure 85 A. Project Stakeholders 85 B. Consultation and Disclosure up to Date 85 C. Future Consultation and Disclosure 86 VII. Grievance Redress Mechanism 87 A. Grievance Redressal Process 88 B. Grievance Redress Committee Composition and Selection of Members 88 VIII. ENVIRONMENTAL MANAGEMENT PLAN 91 A. Environmental Management Plan 91 B. Institutional Arrangements 123 C. Training Needs 127 D. Monitoring and Reporting 128 E. Environmental Management Plan Implementation Cost 129 IX. CONCLUSION AND RECOMMENDATIONS 133 List of Appendices Appendix 1: Rapid Environmental Assessment Checklist135 Appendix 2: Environmental And Labour Related Legislations In India Appendix 3: Applicable Ambient Air Quality And Noise Standards Appendix 4: Applicable Standards For Discharge Of Environmental Pollutants (Effluent) Appendix 5: Applicable Drinking Water Standards Appendix 6: Sample Outline Spoils (Construction Waste) Management Plan Appendix 7: Traffic Management Plan Appendix 8: Stakeholder Consultation Meetings In Mangalore Appendix 9: Land Details Of Project Components Appendix 10 Letter From Commissioner Stating That Land At Panambur Belongs To The Municipality And Is Reserved For An Oht Appendix 11 Details Of Associated Facilities Appendix 12: Semi Annual Environmental Monitoring Report Template Appendix 13: Environmental Audit Of The Existing Water Treatment Plant In Mangalore Appendix 14: Sample Chance Find Protocol Appendix 15 : Sop For Health And Safety (Stop Spread Of Covid -19) Appendix 16 : Who Interim Guidance On Health, Sanitation, Hygiene, And Waste Management For The Covid19 Virus Appendix 17: Grm Notification Appendix 18 Zone Wise Approved Distribution Network Appendix 19 Approved Oht Layouts EXECUTIVE SUMMARY The Asian Development Bank (ADB) funded Karnataka Integrated Urban Water Management Investment Program (KIUWMIP) aims to improve water resource management in urban areas in a holistic and sustainable manner. Investment support is provided to modernize and expand urban water supply and sanitation while strengthening relevant institutions to enhance efficiency, productivity and sustainability in water use. Mangalore 24x7 water supply distribution network subproject is one of the subprojects proposed in Tranche 2. Categorization. ADB requires the consideration of environmental issues in all aspects of the Bank’s operations, and the requirements for environmental assessment are described in its Safeguard Policy Statement (SPS), 2009. The proposed projects are categorized as A, B, C or FI to determine the level of environmental assessment required1. Mangalore water supply subproject is classified as environmental category B as per ADB SPS, 2009 as no significant impacts are envisioned. Accordingly, this initial environmental examination (IEE) report has been prepared. The bulk water supply components proposed under the government funding are required for successful operation of this package. Thus, due diligence for both ADB- and government-funded components have been included in this IEE. Subproject Scope. The subproject formulated under this Investment Program to address gaps in current water supply system. Detailed design of all the subproject components was completed prior to the bidding. As of now the on-ground design validation survey of subproject components are ongoing, the next update of IEE will reflect the results from completed detailed design and design validation survey. This IEE reflect the latest components as per partially completed design validation survey, which includes the following. Scope of work / components as per Latest Scope of work / components as per ongoing detailed design design validation survey (i) clear water feeder mains of 59.45 kilometer (i) Laying of new clear water feeder mains of DI/MS (km) of diameter 200 millimeter (mm) to 660 46.94 Kms. of diameter 200mm to 660mm to overhead mm to overhead tanks (OHTs) and ground tanks and Ground Level Storage Reservoirs. level service reservoirs (GLSRs) (ii) 14 OHTs and 2 GLSRs, (ii) Construction of 14 OHTs (Over Head Tanks) and 2 GLSRs (Ground Level Storage Reservoirs) (iii) distribution network of 789 km (diameter (iii) Laying of 982.80 kms of distribution network in 63 mm to 500 mm); and uncovered areas and 405.93 kms of rider and parallel lines (diameter 63 mm to 500 mm); HDPE and DI. (iv) 7 intermediate pumping stations (iv) Construction of 7 Nos Intermittent Pumping Stations. (v) replacement of 78,969 existing house (v) Replacement of 78,969 existing house service service connections (HSC) along with meters connections along with meters and providing 11,031 and providing 11,031 new metered HSCs to new metered HSCs to uncovered HHs. 1 Per ADB SPS, the environmental categorization and level of environmental assessment required for each category are as follows: (i) Category A: A proposed project is classified as category A if it is likely to have significant adverse environmental impacts that are irreversible, diverse, or unprecedented. These impacts may affect an area larger than the sites or facilities subject to physical works. An environmental impact assessment is required. (ii) Category B: A proposed project is classified as category B if its potential adverse environmental impacts are less adverse than those of category A projects. These impacts are site-specific, few if any of them are irreversible and, in most cases, mitigation measures can be designed more readily than for category A projects. An initial environmental examination is required. (iii) Category C: A proposed project is classified as category C if it is likely to have minimal or no adverse environmental impacts. No environmental assessment is required although environmental implications need to be reviewed. (iv)
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages220 Page
-
File Size-