Count-Based Ratio Method Applied to Multigated Radionucide Angiography

Count-Based Ratio Method Applied to Multigated Radionucide Angiography

Left Ventricular Volume Calculation Using a Count-Based Ratio Method Applied to Multigated Radionucide Angiography Teresa Massardo, Rami A. Gal, Raymond P. Grenier, Donald H. Schmidt, and Steven C. Port University of Wisconsin Medical School, Milwaukee Clinical Campus and Sinai Samaritan Medical Center, Mount Sinai Campus, Milwaukee, Wisconsin based on the fact that the radioactivity recorded from a The purpose of this study was to investigate the accuracy chamber, at equilibrium, is proportional to the volume of a new count-proportional method for the measurement of the chamber. Sorensen et al. showed that stroke ofleft ventricular volume when applied to gated equilibrium counts were directly related to stroke volume measured blood-pool imaging. An equation is developed that relates invasively (10) and both Slutsky et al. (11) and Dehmer total chamber volume, V1,to the area of a pixel (M) and et al. (12,13) calculated absolute volume from chamber the ratio (A) of total counts within the chamber to the activity. The latter required peripheral blood sampling countswithinthe hottestpixelinthechambersuchthat V@ to determine the counts/ml of a reference volume and = 1 .38 M3R312. The value of M is a constant for the applied a regression equation obtained by comparison particular scintillation camera-collimator system and R is obtained from observed count rates. All calculated vol to contrast angiographic volumes. umes were compared to volumes measured using biplane That approach is compromised by the attenuation of contrast ventriculography. In 25 patients, the method for left ventricular counts and the lack of attenuation of ventricular volumes gave an r of 0.95 and an s.e.e. of 23 counts from the reference volume. A method to correct ml [Volume (nuclear) = 0.94 Volume (cath) + 1.3]. End for photon attenuation using the attenuation factor of systolic volume was best calculated from end-diastolic water (@:0.l5 cm@) has been proposed by Links (14) volume and ejection fraction. Manual regions of interest and also used by others (15,16). However, the assump were more accuratethan automatedregionsof interest. tion that the density ofthe whole chest is similar to that Thismethodappearsto be as accurateas morecomplex of water has been amply disputed. The range of the approaches and has the advantage of not requiring atten attenuation factor has been estimated to be 0.08 to 0.16 uation correction or blood sampling. cm' (11—22). J NucI Med 1990; 31:450—456 Maurer (23) reported the use of an intraesophageal source to calculate a transmission factor for individual determination ofattenuation. Harpen (24) used a trans mission factor from a first-pass acquisition. Another he first non-invasive radionuclide angiographic approach to solve this problem was the use of a “build (RNA) approach to left ventricular volume determina up factor,―which also attempted to correct for scatter tion was a geometric technique applying the formulas activity (25,26). The methods that correct for attenua used in contrast angiography (1). Other authors have tion require a measurement of the distance from the also utilized geometric techniques (2—6).The disadvan center of the left ventricle (LV) to the collimator. That tages of the geometric methods include the limited was commonly obtained through a trigonometric func resolution of RNA studies and the application of a tion using a static anterior view (18) or a two-dimen prolate ellipsoid model to ventricles in which dilatation sional echocardiographic technique (16). A last ap or wall motion abnormalities distort the shape (a limi proach has used SPECT with a known voxel size and tation inherent in most geometric approaches). An early no background correction; however, that is a very corn nongeometric approach used dilution curve analysis plex and time-consuming method (27). ( 7,8) but was also shown to have significant limitations Bourguignon (28) has developed a method of volume (9). Count-proportional, nongeometric methods are calculation based on aortic arch counts and background correction (that should be similar in the aorta and LV) without blood sampling. ReceivedOct. 24, 1988;revisionaccepted Oct. 31, 1989. A count density distribution method has also been For reprints contact: Steven C. Port, MD, cardiovascular Disease Section,SinaiSamaritanMediCalcenter,950N.12thSt.,Milwaukee,WI described (29-31) and applied to first-pass RNA acqui 53233. sitions. That approach was based on a measurement of 450 The Journal of Nuclear Medicine •Vol. 31 •No. 4 •April 1990 the ratio of total counts to peak pixel counts in the LV. The constant of proportionality is eliminated by taking the The ratio was shown to be a function of the volume. ratio R = Ct/Nm which from Equations 1 and 2 is as follows: That technique is particularly attractive since neither — C, Ky, _ V1 _ /6D3 /61Y @ attenuation correction nor blood sampling is required. R - N KVmf Vm@ M2D M2. (3) In the present report, we expand on that particular It is clear that R is a dimensionless quantity that is equal to count-based theory and describe its application to mul the number of reference volumes contained in the entire tigated equilibrium radionuclide angiography (EqRNA) spherical volume. (32). Equation 3 may be solved for D as follows: D = 6M2R. (4) METHODS The volume of the sphere is: Count Proportional Volume Theory Vt = /6D3, hence from Equation 4, From a homogeneously mixed volume ofa gamma emitting V5= /6 6M2R3 tracer, the total number of gamma rays that pass through a multichannel collimator (total count) is proportional to the volume, independent ofits shape. The maximum pixel count or, is proportional to an effective reference volume defined as the V, = 1.38 M3R312 (5) product of the length of the longest axis perpendicular to the collimator and the cross-sectional area of the pixel. The con The volume of the sphere, in cm3, is directly obtained from stant ofproportionality can be eliminated by forming the ratio Equation 5 since M is known for any pixel matrix and R is oftotal counts to maximum pixel counts. the observed count ratio. That ratio is fundamentally a measure of the number of reference volumes contained in the total volume. The key, Patient Population then, to the determination of total volume is to determine the Twenty-five patients were prospectively studied, 16of them exact volume of the reference volume. For many volume males and 9 females, with a mean age of 62.8 and a range of shapes (e.g., spheres, ellipsoids, cylinders), the reference vol 38 to 83 yr. They were recruited from the population undergo ume is readily determined. ing routine diagnostic catheterization. The only selection cri In general, a reference volume theorem is defined as follows: teria were the patient's clinical stability, the possibility of the reference volume (cm3) is always equal to the pixel area performing a biplane left ventriculogram prior to any other (cm2) times the longest axis (cm). The reference volume angiography, and the availability ofthe portable gamma cam theorem can be proven for a broad class of parallel-hole era. Documented informed consent was obtained from all multichannel collimators, including all the collimators used patients. in practice with scintillation camera systems. The theorem is independent of the spatial resolution, the efficiency of the Radionuclide Acquisition collimator, the shape of the collimator holes, or the distance EqRNA was performed in the catheterization laboratory of the source from the collimator. The rigid and formal immediately after arterial access was obtained and before mathematical proof of the reference volume theorem is be biplane angiography was done. yond the scope ofthis article: however, empirical proof of this In vivo red cell labeling was used with injection of 1.2 mg theorem is easily obtained by measuring a variety of known of Sn-pyrophosphate followed, 20 mm later, by 925 Mbq (25 volume distributions with any gamma scintillation camera at mCi) of technetium-99m-pertechnetate. The best combina different distances from the collimator, with different colli tion of left anterior oblique and caudal angulations was se mators and with different sampling matrices. lected for separation of the two ventricles. The RNA was The practical applications of the reference volume theorem performed with a portable, small field of view (200 mm) can be simply illustrated by using a spherical volume of gamma camera equipped with an all-purpose, low-energy, distribution as an example. Let a spherical volume of diame parallel-hole collimator. Data were acquired in frame mode ter, D, filled with a homogeneous solution of gamma-emitting using 24 frames per cycle, a matrix of64x64 pixels, an energy tracer, be measured with a multichannel collimator/scintilla window of 140 keV ±10% and a beat-rejection window of tion camera system using a sampling matrix with pixel dimen 15%. Beats within the window were interpolated “on-the-fly― sion equal to M, in cm, so that the cross-sectional area of each so that a uniform LV time-activity curve was generated. The pixel is equal to M2. The reference volume theorem states that acquisition was stopped at pixel saturation and total counts the reference volume, Vr, is equal to M2D. In this example, averaged 6-8 x 106. the pixel which samples Vr is clearly the pixel with maximum counts, (Nm). Nm is proportional to V@,hence: Data Processing Nm KVr = KM2D, (1) The LV ejection fraction (EF) was calculated in the 25 studies using automated and manual programs. With the where K is the constant of proportionality with dimensions counts/cm3. The total counts, C,, is proportional to the total automated method, the regions of interest (RO!) were gener ated using a second derivative edge detection threshold. A volume of the sphere, V,, hence: semicircular shaped background ROI was created around the Cl = Ky, = K/6D3.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    7 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us