sheet index project data: SHEET NUMBER SHEET NAME

OWNER NAME = 204 J STREET HOLDING, LLC a0.0 TITLE SHEET OWNER ADDRESS = 850 SOUTH COAST HIGHWAY 101 ENCINITAS, CA 92024 a0.1 SITE PLAN & PROJECT AREAS

OWNER TELEPHONE = (760) 621-8721 a0.2 DISABLED ACCESSIBILITY SHEET a0.3 DISABLED ACCESSIBILITY SHEET PROJECT ADDRESS = 202, 206, 210, 214 WEST J STREET 08/31/2021 ENCINITAS, CA 92024 a0.4 DISABLED ACCESSIBILITY SHEET 202 W J STREET- EASTERLY COMMERCIAL SPACE- BP NO. 19-1964 a0.5 SCHEDULES, SYMBOLS & ABBREVIATIONS 206 W J STREET- EASTERLY RESIDENCE ABOVE- BP NO. 19-1962 210 W J STREET- WESTERLY COMMERCIAL SPACE- BP NO. 19-1965 a0.6 GENERAL NOTES 214 W J STREET- WESTERLY RESIDENCE ABOVE- BP NO. 19-1963 a1.0 FIRST PLAN APN = 258-293-09-00 a1.1 SECOND FLOOR PLAN

LEGAL DESCRIPTION = LOT 8 IN BLOCK 15, MAP NO. 148, a1.2 PLAN TOWNSITE OF ENCINITAS a2.0 ELEVATIONS PROJECT = A TWO-STORY MIXED-USE BUILDING CONSISTING a2.1 BUILDING ELEVATIONS DESCRIPTION OF (2) COMMERCIAL UNITS ON FIRST FLOOR, (2) TWO- a3.0 BUILDING SECTIONS RESIDENTIAL UNITS ON SECOND FLOOR AND AN ATTACHED ACCESSORY DWELLING UNIT. a3.1 BUILDING SECTIONS

PLANNING CASE = 07-154 TPM/CDP a4.0 INTERIOR ELEVATIONS a5.0 TRASH ENCLOSURE OCCUPANCY = B , COMMERCIAL R-3, RESIDENTIAL d0.0 ARCHITECTURAL DETAILS d0.1 ARCHITECTURAL DETAILS CONSTRUCTION TYPE = V-N d0.2 WATERPROOFING DECKING DETAILS ZONE = D-CM-2 S1.0 STRUCTURAL NOTES OVERLAYS = COASTAL ZONE S1.1 STRUCTURAL NOTES OVERLAY SPECIAL OVERLAY SPECIFIC PLAN BOUNDARY S1.2 STRUCTURAL TYPICAL DETAILS S1.3 STRUCTURAL TYPICAL DETAILS GROSS LOT AREA = 5,000 SQ FT NET LOT AREA = 5,000 SQ FT S2.0 PLAN S3.0 SECOND FLOOR FRAMING PLAN BUILDING AREAS S4.0 ROOF FRAMING PLAN 2 0 4 W E S T J S T R E E T EXISTING STRUCTURE TO DEMOLISH = 1,808 SF SD1 STRUCTURAL DETAILS COMMERCIAL SUITE 1 = 780 SF SD2 STRUCTURAL DETAILS COMMERCIAL SUITE 2 = 810 SF TOTAL COMMERCIAL = 1,590 SF SD3 STRUCTURAL DETAILS ATTACHED ADU = 842 SF M0.1 MECHANICAL LEGENDS, SCHEDULES & NOTES RESIDENTIAL UNIT 1 = 808 SF project team: RESIDENTIAL UNIT 2 = 808 SF M0.2 MECHANICAL LEGENDS, SCHEDULES & NOTES adu information: parking analysis: TOTAL RESIDENTIAL = 2,458 SF UNIT 1 = 928 SF M1.1 MECHANICAL FIRST FLOOR PLAN ARCHITECT = DZN PARTNERS BALCONY UNIT 2 = 554 SF M1.2 MECHANICAL SECOND FLOOR PLAN 682 SECOND ST CODE SECTION 65852.2(e) TOTAL = 1,428 SF REQUIRED ENCINITAS, CA 92024 M2.1 MECHANICAL DETAILS (760) 753-2464 (E) (1) NOTWITHSTANDING SUBDIVISIONS (A) TO (D), INCLUSIVE, A LOCAL AGENCY FLOOR AREA RATIO = (780+810)+(808+808)+(842) = 4048 M2.2 MECHANICAL DETAILS COMMERCIAL 1.0 SPACE PER 300sf BART SMITH, AIA 4048 / 5000 = .809 SHALL MINISTERIALLY APPROVE AN APPLICATION FOR A BUILDING PERMIT WITHIN [email protected] A RESIDENTIAL OR MIXED-USE ZONE TO CREATE ANY OF THE FOLLOWING: 1590 / 300 = 5.3 M3.1 ENERGY COMPLIANCE DOCUMENTS (A) ONE ACCESSORY DWELLING UNIT OR ONE JUNIOR ACCESSORY DWELLING LOT COVERAGE = 3000 / 5000 = 60% M3.2 ENERGY COMPLIANCE DOCUMENTS TOTAL SPACES REQUIRED 5.3 PROJECT = DZN PARTNERS (USING NET LOT AREA) UNIT PER LOT WITH A PROPOSED OR EXISTING SINGLE-FAMILY DWELLING IF ALL manager 682 SECOND ST OF THE FOLLOWING APPLY: M3.3 ENERGY COMPLIANCE DOCUMENTS PROVIDED ENCINITAS, CA 92024 PARKING = SEE PARKING ANALYSIS (I) THE ACCESSORY DWELLING UNIT OR JUNIOR ACCESSORY DWELLING UNIT IS (760) 753-2464 M000 MECHANICAL GENERAL NOTES, LEGEND AND SHEET LIST WITHIN THE PROPOSED SPACE OF A SINGLE-FAMILY DWELLING OR EXISTING West J ST ON-STREET 8 SPACES / 2 LOTS = 4.00 MEAGHAN LAWLER GRADING = SEE GRADING PLAN, GRADING PLAN 14164-G SPACE OF A SINGLE-FAMILY DWELLING OR ACCESSORY STRUCTURE AND MAY [email protected] M001 MECHANICAL TITLE 24 SHEET INCLUDE AN EXPANSION OF NOT MORE THAN 150 SQUARE FEET BEYOND THE SAME PHYSICAL DIMENSIONS AS THE EXISTING ACCESSORY STRUCTURE. AN 2nd ST ON-STREET 15 SPACES / 8 LOTS = 1.875 EARTHWORK DATA M101 MECHANICAL FLOOR PLAN SOILS = HETHERINGTON ENGINEERING, INC. CUT = 30 C.Y. EXPANSION BEYOND THE PHYSICAL DIMENSIONS OF THE EXISTING ACCESSORY engineer 5365 AVENIDA ENCINAS, SUITE A M501 MECHANICAL DETAILS STRUCTURE SHALL BE LIMITED TO ACCOMMODATING INGRESS AND EGRESS. 5.875 SPACES ON STREET FILL = 70 C.Y. CARLSBAD, CA 92008 (II) THE SPACE HAS EXTERIOR ACCESS FROM THE PROPOSED OR EXISTING IMPORT = 40 C.Y. M502 MECHANICAL DETAILS ON-SITE 1 ACCESSIBLE SPACE (760) 931-1917 REMEDIAL = 500 C.Y. SINGLE-FAMILY DWELLING. MARK HETHERINGTON M601 MECHANICAL SCHEDULES (III) THE SIDE AND REAR SETBACKS ARE SUFFICIENT FOR FIRE AND SAFETY. [email protected] (IV) THE JUNIOR ACCESSORY DWELLING UNIT COMPLIES WITH THE IMPERVIOUS SA PRIOR TO CONSTRUCTION = 3,379 SF P0.1 LEGEND NOTES & SCHEDULES REQUIREMENTS OF SECTION 65852.22. TOTAL SPACES PROVIDED 6.875 IMPRVIOUS SA AFTER CONSTRUCTION = 3,635 SF CIVIL = PASCO LARET SUITER & ASSOCIATES INCREASE IN IMPERVIOUS SA = 256 SF P0.2 PLUMBING LEGEND NOTES & SCHEDULES (B) ONE DETACHED, NEW CONSTRUCTION, ACCESSORY DWELLING UNIT THAT engineer 535 NORTH COAST HIGHWAY 101 SUITE A DOES NOT EXCEED FOUR-FOOT SIDE AND REAR YARD SETBACKS FOR A LOT IMPERVIOUS AREA REPLACED = 3,635 SF P0.3 PLUMBING LEGEND NOTES & SCHEDULES THE REQUIRED NUMBER OF SPACES FOR THIS PROJECT IS 5.3. THE SOLANA BEACH, CA 92075 WITH A PROPOSED OR EXISTING SINGLE-FAMILY DWELLING. THE ACCESSORY (858) 259-8212 DWELLING UNIT MAY BE COMBINED WITH A JUNIOR ACCESSORY DWELLING UNIT PROPOSED FIRE SPRINKLERS = YES, PROPOSED, TYPE 13D P1.0 FIRST FLOOR DOMESTIC WATER PLAN NUMBER OF PARKING SPACES EXCEEDS THIS REQUIREMENT BY BRYAN KNAPP DESCRIBED IN SUBPARAGRAPH (A). A LOCAL AGENCY MAY IMPOSE THE [email protected] P1.1 FIRST FLOOR WASTE & VENT PLAN FOLLOWING CONDITIONS ON THE ACCESSORY DWELLING UNIT: PROVIDING 6.875 NOISE CRITICAL AREA = NO SPACES. P1.2 FIRST FLOOR NATURAL GAS PLUMBING PLAN (I) A TOTAL FLOOR AREA LIMITATION OF NOT MORE THAN 800 SQUARE FEET. LANDSCAPE = JPBLA, INC. LANDSCAPE ARCHITECTS (II) A HEIGHT LIMITATION OF 16 FEET. architect 4403 MANCHESTER AVE #201 P2.0 SECOND FLOOR DOMESTIC WATER PLUMBING PLAN (C) (I) MULTIPLE ACCESSORY DWELLING UNITS WITHIN THE PORTIONS OF NOTE: PER CALIFORNIA STATE ADU LAW, THIS MULTIFAMILY ENCINITAS, CA 92024 GOVERNING CODES = PART 2: 2016 CA BUILDING CODE EXISTING MULTIFAMILY DWELLING STRUCTURES THAT ARE NOT USED AS LIVABLE (760) 479-0644 P2.1 SECOND FLOOR WASTE & VENT PLAN SPACE, INCLUDING, BUT NOT LIMITED TO, STORAGE , BOILER ROOMS, RESIDENTIAL SITE IS ALLOWED TO CONVERT NON HABITABLE SPACE, PART 2.5: 2016 CA RESIDENTIAL CODE SUCH AS A , INTO AN ACCESSORY DWELLING UNIT WITHOUT JIM BENEDETTI PART 3: 2016 CA ELECTRICAL CODE P2.2 SECOND FLOOR NATURAL GAS PLUMBING PLAN PASSAGEWAYS, , , OR GARAGES, IF EACH UNIT COMPLIES [email protected] WITH STATE BUILDING STANDARDS FOR DWELLINGS. REQUIREMENT TO REPLACE RESIDENTIAL PARKING PROVIDED BY THE PART 4: 2016 CA MECHANICAL CODE P3.0 DOMESTIC WATER ISOMETRIC PLAN (II) A LOCAL AGENCY SHALL ALLOW AT LEAST ONE ACCESSORY DWELLING UNIT GARAGE. AS SUCH, NO RESIDENTIAL PARKING IS PROVIDED BEYOND PART 5: 2016 CA PLUMBING CODE WHAT REMAINDER CREDIT THERE IS FOR ON STREET PARKING AFTER STRUCTURAL ENGINEER = QUALLS ENGINEERING PART 6: 2016 CA ENERGY CODE P3.1 WASTE & VENT ISOMETRIC PLAN WITHIN AN EXISTING MULTIFAMILY DWELLING AND SHALL ALLOW UP TO 25 4403 MANCHESTER AVE PERCENT OF THE EXISTING MULTIFAMILY DWELLING UNITS. IT IS APPLIED TO THE COMMERCIAL SPACE. PART 9: 2016 CA FIRE CODE ENCINITAS, CA 92024 PART 11: 2016 CA GREEN BLDG P3.2 NATURAL GAS ISOMETRIC PLAN (D) NOT MORE THAN TWO ACCESSORY DWELLING UNITS THAT ARE LOCATED ON 760-652-9257 A LOT THAT HAS AN EXISTING MULTIFAMILY DWELLING, BUT ARE DETACHED SEE ITEM 4 OF SUBDIVISION E: ADUS CREATED UNDER SUBDIVISION (E) STANDARDS CODE P4.0 PLUMBING DETAILS SHALL NOT BE REQUIRED TO PROVIDE REPLACEMENT OR ADDITIONAL BRIAN QUALLS FROM THAT MULTIFAMILY DWELLING AND ARE SUBJECT TO A HEIGHT LIMIT OF 16 [email protected] FEET AND FOUR-FOOT REAR YARD AND SIDE SETBACKS. PARKING. P4.1 PLUMBING DETAILS (2) A LOCAL AGENCY SHALL NOT REQUIRE, AS A CONDITION FOR MINISTERIAL MECHANICAL + PLUMBING = RIVERSIDE ENGINEERING L4(A) ALL LANDSCAPPING, FENCES, , ETC. ON THE SITE, IN ANY ADJOINING PUBLIC PARKWAYS (THE P000 PLUMBING, GENERAL NOTES, LEGEND AND SHEET LIST APPROVAL OF A PERMIT APPLICATION FOR THE CREATION OF AN ACCESSORY THE OFFICE/RETAIL BUILDING SHALL NOT ALLOW ANY FUTURE ON AREA BETWEEN THE FRONT PROPERTY LINE AND THE STREET) SHALL BE PERMANENTLY 2ND N J SITE, UTILIZING A PARKING RATIO GREATER THAN ONE (1) SPACE engineer 5005 LA MART DRIVE #206 P001 PLUMBING CALCULATIONS AND SCHEDULES DWELLING UNIT OR A JUNIOR ACCESSORY DWELLING UNIT, THE CORRECTION OF RIVERSIDE, CA 92507 MAINTAINED BY THE OWNER, ASSIGNS OR ANY SUCCESSORS IN INTEREST IN THE PROPERTY. THE STREET FOR EACH 300 SQUARE FEET OF GROSS BUILDING FLOOR AREA NONCONFORMING ZONING CONDITIONS. (951) 977-1042 MAINTENANCE PROGRAM SHALL INCLUDE NORMAL CARE AND IRRIGATION OF THE LANDSCAPING; P101 PLUMBING FLOOR PLAN (3) THE INSTALLATION OF FIRE SPRINKLERS SHALL NOT BE REQUIRED IN AN WITHOUT A MODIFICATION TO THE DESIGN REVIEW PERMIT CONTAIN REPAIR AND REPLACEMENT OF PLANT MATERIALS AND IRRIGATION SYSTEMS AS NECESSARY; AND HEREIN, AS PER THE REGULATIONS OF CHAPTER 23.08 (DESIGN JOSHUA BELTRAN ACCESSORY DWELLING UNIT IF SPRINKLERS ARE NOT REQUIRED FOR THE [email protected] GENERAL CLEANUP OF THE LANDSCAPED AND OPEN AREAS, PARKING LOTS AND WALKWAYS, P501 PLUMBING DETAILS PRIMARY RESIDENCE. REVIEW) OUTLINED IN THE ENCINITAS MUNICIPAL CODE AND THE WALLS, FENCES, ETC. FAILURE TO MAINTAIN LANDSCAPING AND THE SITE IN GENERAL MAY RESULT DOWNTOWN ENCINITAS SPECIFIC PLAN. P701 PLUMBING DIAGRAMS (4) A LOCAL AGENCY MAY REQUIRE OWNER OCCUPANCY FOR EITHER THE MECHANICAL + PLUMBING = BSE ENGINEERING IN THE SETTING OF A PUBLIC HEARING TO REVOKE OR MODIFY THE APPROVAL. THIS CONDITION PRIMARY DWELLING OR THE ACCESSORY DWELLING UNIT ON A SINGLE-FAMILY engineer (858) 800-6000 SHALL BE RECORDED WITH THE COVENANT REQUIRED BY THIS RESOLUTION. E0.1 ELECTRICAL NOTES, LEGEND & LUMINAIRE SCHEDULE LOT, SUBJECT TO THE REQUIREMENTS OF PARAGRAPH (6) OF SUBDIVISION (A). PAUL LUSTER E0.2 ELECTRICAL DETAILS (5) A LOCAL AGENCY SHALL REQUIRE THAT A RENTAL OF THE ACCESSORY [email protected] DWELLING UNIT CREATED PURSUANT TO THIS SUBDIVISION BE FOR A TERM E1.0 ELECTRICAL SITE PLAN NOTE: THIS PROJECT IS NOT WITHIN A NOISE CRITICAL AREA (CNEL CONTOUR OF 60 DB) AS SHOWN CITY: ENCINITAS LONGER THAN 30 DAYS. ELECTRICAL = NEDC, INC. ON THE GENERAL PLAN. E2.0 ELECTRICAL FIRST FLOOR PLAN (6) A LOCAL AGENCY MAY REQUIRE, AS PART OF THE APPLICATION FOR A PERMIT engineer 3103 FALCON STREET SUITE J TO CREATE AN ACCESSORY DWELLING UNIT CONNECTED TO AN ONSITE SAN DIEGO, CA 92103 E2.1 ELECTRICAL SECOND FLOOR LIGHTING PLAN 2019.08-19 WASTEWATER TREATMENT SYSTEM, A PERCOLATION TEST COMPLETED WITHIN (619) 278-0076 THE LAST FIVE YEARS, OR, IF THE PERCOLATION TEST HAS BEEN RECERTIFIED, DAVID NUTTER E3.0 ELECTRICAL FIRST FLOOR POWER PLAN 2019.11-18 WITHIN THE LAST 10 YEARS. [email protected] E3.1 ELECTRICAL SECOND FLOOR POWER PLAN (7) NOTWITHSTANDING SUBDIVISION (C) AND PARAGRAPH (1) A LOCAL AGENCY 2020.01-15 THAT HAS ADOPTED AN ORDINANCE BY JULY 1, 2018, PROVIDING FOR THE green building standards notes: E4.0 ELECTRICAL PANELS AND CALCS APPROVAL OF ACCESSORY DWELLING UNITS IN MULTIFAMILY DWELLING 2020.05-04 STRUCTURES SHALL MINISTERIALLY CONSIDER A PERMIT APPLICATION TO E4.1 ELECTRICAL SINGLE LINE DIAGRAM CONSTRUCT AN ACCESSORY DWELLING UNIT THAT IS DESCRIBED IN PARAGRAPH 1. THE SITE SHALL BE PLANNED AND DEVELOPED TO KEEP SURFACE WATER AWAY FROM . E5.0 ELECTRICAL T-24 FORMS 2020.08-28 (1), AND MAY IMPOSE STANDARDS INCLUDING, BUT NOT LIMITED TO, DESIGN, vicinity map: PLANS SHALL BE PROVIDED AND APPROVED BY THE CITY ENGINEER THAT SHOW SITE GRADING AND DEVELOPMENT, AND HISTORIC STANDARDS ON SAID ACCESSORY DWELLING square footages: PROVIDE FOR STORM WATER RETENTION AND DRAINAGE DURING CONSTRUCTION. BMPs THAT ARE E5.1 ELECTRICAL T-24 FORMS UNITS. THESE STANDARDS SHALL NOT INCLUDE REQUIREMENTS ON MINIMUM CURRENTLY ENFORCED BY THE CITY ENGINEER MUST BE IMPLEMENTED PRIOR TO INITIAL INSPECTION THE CHART BELOW INDICATES THE SQUARE FOOTAGE AND FA R JOB: LOT SIZE. BY THE BUILDING DEPARTMENT. CGC 4.106.3. L-1 LANDSCAPE TITLE PAGE 201856R CHANGES BETWEEN APPROVED CASE NO. SUBC-003117-2019 AND H STREET 2. A MIN OF 65% OF CONSTRUCTION WASTE IS TO BE RECYCLED. CGC 4.408.1. S L-2 HARDSCAPE PLAN PROPOSED CASE NO. SUBC-004043-2020. 3. THE BUILDER IS TO PROVIDE AN OPERATION MANUAL (CONTAINING INFORMATION FOR

2 C

N 3

R O D MAINTAINING APPLIANCES, ETC.) FOR THE OWNER AT TIME OF FINAL INSPECTION. CGC 4.410.1. L-3 DIMENSION AND SPOT ELEVATION PLAN TITLE SHEET

D

S A

S T 4. DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TO BE SEALED, AND MECHANICAL EQPT IS S R T L-4 CONSTRUCTION DETAILS R ACCORDING TO PAGE 14 OF THE 2020.09 CALIFORNIA ADU HANDBOOK, H) E T OAD TO BE COVERED. CGC 4.504.1. E E A R MELB E T H

CONVERSION OF EXISTING SPACE IN SINGLE FAMILY, ACCESSORY AND T 5. VOCs MUST COMPLY WITH THE LIMITATIONS LISTED IN SEC 4.504.3 AND TABLES 4.504.1, 4.504.2, I L-5 IRRIGATION PLAN G I STREET 4.504.3 AND 4.504.5 for: ADHESIVES, PAINTS AND COATINGS, CARPET AND COMPOSITION WOOD MULTIFAMILY STRUCTURES AND OTHER STATEWIDE PERMISSIBLE ADUS H

(SUBDIVISION E) : W PRODUCTS. CGC 4.504.2. L-6 IRRIGATION NOTES A 6. IF PROVIDED, WHOLE EXHAUST FANS SHALL HAVE INSULATED COVERS OR Y L-7 IRRIGATION DETAILS

1. LOCAL ANGENCIES ARE REQUIRED TO COMPLY WITH SUBDIVISION (E). 1 WHICH CLOSE WHEN THE FAN IS OFF. THE COVERS OR LOUVERS SHALL HAVE MIN R4.2 INSULATION.

0

ADUS UNDER THIS SUBDIVISION SHOULD NOT HAVE TO COMPLY WITH LOT 1 CGC 5.507.1. L-8 IRRIGATION DETAILS COVERAGE, SETBACKS, HEIGHTS, AND UNIT SIZES. 7. FANS SHALL BE ENERGY STAR RATED, VENTED DIRECTLY TO THE OUTSIDE AND L-9 IRRIGATION SPECIFICATIONS 2. THERE ARE FOUR CATEGORIES OF ADUS UNDER SUBDIVISION (E). J STREET CONTROLLED BY A HUMIDISTAT. CGC 4.506.1. V PERTAINING TO THIS PROJECT IS CATEGORY C: MULTIPLE ADUS WITHIN U 8. HEATING AND AC SHALL BE SIZED AND SELECTED BY ACCA MANUAL J OR ASHRAE HANDBOOK OR L-10 IRRIGATION WATER CALCULATIONS

L

THE PORTIONS OF MULTIFAMILY STRUCTURES THAT ARE NOT USED AS C EQUIVALENT. THE DUCT SIZING SHALL BE SIZED IN ACCORDANCE WITH ONE OF THE ACCA LIVABLE SPACE. LOCAL ANGENCIES MUST ALLOW AT LEAST ONE OF A METHODS LISTED IN CGC SECTION 4.507.2. L-11 PLANTING PLAN N

9. PRIOR TO FINAL APPROVAL OF THE BUILDING THE LICENSED CONTRACTOR, ARCHITECT, OR THESE TYPES OF ADUS AND UP TO 25 PERCENT OF THE EXISTING A L-12 PLANTING DETAILS MULTIFAMILY STRUCTURES. V ENGINEER IN RESPONSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST COMPLETE AND SIGN STREET E 3. LOCAL AGENCIES SHALL ALLOW AT LEAST ONE ADU TO BE CREATED K THE GREEN BUILDING STANDARDS CERTIFICATION FORM AND GIVE TO THE BUILDING DEPARTMENT L-13 PLANTING SPECIFICATIONS WITHIN THE NON-LIVABLE SPACE WITHIN MULTIFAMILY DWELLING OFFICIAL TO BE FILED WITH THE APPROVED PLANS. L-14 PLANTING SPECIFICATIONS STRUCTURES, OR UP TO 25 PERCENT OF THE EXISTING MULTIFAMILY SANTA FE DR 10. LANDSCAPE IRRIGATION WATER USE SHALL HAVE WEATHER BASED CONTROLLERS. CGC 4.304.1. DWELLING UNITS WITHIN A STRUCTURE. 11. WHEN A SHOWER IS PROVIDED WITH MULTIPLE SHOWER HEADS, THE SUM OF FLOW TO ALL THE L-15 AGRONOMIC SOILS REPORT 4. ADUS CREATED UNDER SUBDIVISION (E) SHALL NOT BE REQUIRED TO HEADS SHALL NOT EXCEED THE 20% REDUCED LIMIT, OR THE SHOWER SHALL BE DESIGNED SO THAT PROVIDE REPLACEMENT OR ADDITIONAL PARKING. PACIFIC OCEAN ONLY ONE HEAD IS ON AT A TIME. CGC 4.303.2. L-16 AGRONOMIC SOILS REPORT a0.0 * SEE PARKING ANALYSIS, THIS SHEET. NOTE: A FAR VALUE EXCEEDING THE ALLOWABLE .75 VALUE IS PERMITTED 12. INTERIOR MOISTURE CONTROL: THE MOISTURE CONTENT OF WOOD SHALL NOT EXCEED 19% L-17 LIGHTING PLAN & LEGEND ACCORDING TO CALIFORNIA STATE ADU LAWS. BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURE CONTENT NEEDS TO BE CERTIFIED BY ONE OF THE 3 METHODS SPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMANGE C-1 GRADING PLAN SHOULD NOT BE USED IN CONSTRUCTION. THE MOISTURE CONTENT MUST BE DETERMINED BY THE 204 WEST J STREET C-2 GRADING PLAN CONTRACTOR BY ONE OF THE METHODS LISTED IN CGC SECTION 4.505.3. C-3 GRADING PLAN C-4 GRADING PLAN