MTL11 875 St. Antoine, , Quebec

Quick Facts: Montreal’s Secondary Carrier Hotel

• 25K SQF MTL11 is a new interconnection hub for Cologix, located at 875 St. Antoine in downtown Montreal. MTL11 operates the only other carrier • Secondary carrier hotel in hotel in Montreal. Located six blocks from Cologix’s MTL3 data center, Montréal the primary carrier hotel in the region, these facilities offer direct connectivity between the two sites. This new facility expands Cologix’s • 30+ carriers & multiple footprint in the region with unique subsea cable routes into Montreal as carriers onsite well as 30+ new carriers to the Cologix ecosystem. • MetroIX Cloud Ecosystem • 100+ unique networks Canada’s Interconnection Gateway accessible via dark fibre in Montreal Cologix operates 11 data centres in the market plus the largest Meet- Me-Room (MMR) in Montreal’s premiere carrier hotel, offering direct • 100% control of critical connectivity to the main hyperscale customers with access to nearly 100 data center infrastructure carriers through a diverse, dark fibre ring.

30+ Network Neutral Data Centres Throughout

U.S.:

Ashburn • Columbus • Dallas • Jacksonville • Lakeland • Minneapolis • New Jersey CAN:

Montreal • Tour the MTL11 Data Centre: 875 St. Antoine Why Cologix in Montreal? Montréal, Québec Cologix is the market leader in Canada with a presence in Montreal, To schedule, contact: Toronto and Vancouver. With robust connectivity via diverse dark fibre [email protected] or and a very high bandwidth, hyperscale and enterprise customers value the richness of connectivity options from Cologix as well as the reliability, +1.855.497.2537 upgrades, redundancies and ease of doing business with Cologix.

MTL11 MONTREAL DATA CENTRE Site Specifications MTL11: 875 St. Antoine, Montreal,

Site Information Power Renewable, green Energy: hydroelectric power MTL11 Space: 25K SQF 2 power entrances; 1 active, Entrance: Total Montreal Space: 790K SQF 1 passive

1992; concrete, granite, glass, steel; UPS: 2 x Powerware 9315 225 kVA Building: seismic 2A

Load: 1 MW Custom cabinets & cages with Space Configuration: hot & cold aisle; customize ATS: Cummins, ASCO, Caterpillar container options

Security Connectivity Meet-Me-Room (MMR): Yes, Cologix controlled Closed-Circuit TV: Yes

Number of Networks: 30+ network options Security: Onsite guards Network Neutral: Yes Yes, optional biometric readers for Customized Security: private suites 7 independent fiber entry points and Fibre Entrance: 2 meet me rooms Access: Keycard Cross Connects: Copper, fibre, virtual Man Traps: Yes Low-latency location: long-haul fiber Latency: aggregation point

Environmental Controls Services: Dark, lit & wave

Diverse dark fibre between 11 Communications: Cooling Capacity: 600 tons, N+1 Cologix facilities and carrier hotels

Cooling Type: Chilled water

Fire Suppression: Pre-action fire sprinkler system

Humidification: Yes

Remotely Monitored: Yes

Sales WWW.COLOGIX.COM +1.855.265.6449 [email protected] F20V1-MTL11