Dell EMC SC Series: Oracle Best Practices

Total Page:16

File Type:pdf, Size:1020Kb

Dell EMC SC Series: Oracle Best Practices Best Practices Dell EMC SC Series: Oracle Best Practices Abstract Best practices, configuration options, and sizing guidelines for Dell EMC™ SC Series storage in Fibre Channel environments when deploying Oracle®. May 2020 CML1114 Revisions Revisions Date Description January 2012 Initial release April 2012 Content and format change July 2013 Added ORION information provided by Copilot April 2015 Content and format change July 2017 Major rewrite. Made document agnostic with respect to Dell EMC SC series arrays. Format changes. August 2018 Content changes for preallocation May 2020 Changed setting of port down Acknowledgments Author: Mark Tomczik The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. Copyright © 2012-2020 Dell Inc. or its subsidiaries. All Rights Reserved. Dell Technologies, Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. [5/12/2020] [Best Practices] [CML1114] 2 Dell EMC SC Series: Oracle Best Practices | CML1114 Table of contents Table of contents Revisions............................................................................................................................................................................. 2 Acknowledgments ............................................................................................................................................................... 2 Table of contents ................................................................................................................................................................ 3 Executive summary ............................................................................................................................................................. 6 How to use this document................................................................................................................................................... 6 Audience ............................................................................................................................................................................. 6 Prerequisites ....................................................................................................................................................................... 6 1 Introduction ................................................................................................................................................................... 7 1.1 Manageability ...................................................................................................................................................... 7 1.2 High availability ................................................................................................................................................... 7 1.3 Performance ....................................................................................................................................................... 7 2 Fibre Channel connectivity ........................................................................................................................................... 9 2.1 Zoning ................................................................................................................................................................. 9 2.1.1 Soft (WWN) zoning ............................................................................................................................................. 9 2.1.2 Hard (port) zoning ............................................................................................................................................. 13 2.2 QLogic settings ................................................................................................................................................. 13 2.2.1 Server FC HBA BIOS settings .......................................................................................................................... 13 2.2.2 Server FC HBA driver settings: timeouts and queue depth ............................................................................. 15 3 SC Series array .......................................................................................................................................................... 16 3.1 SC Series features ........................................................................................................................................... 16 3.2 Benefits of deploying Oracle on SC Series storage ......................................................................................... 17 3.3 SC Series back-end connections ..................................................................................................................... 17 3.4 Virtual port mode .............................................................................................................................................. 17 3.5 Fault domains in virtual port mode ................................................................................................................... 18 3.6 Redundancy for SC Series front-end connections ........................................................................................... 19 3.7 Creating server objects in SC Series arrays .................................................................................................... 19 3.8 Disk pools and disk folders ............................................................................................................................... 21 3.9 Storage types .................................................................................................................................................... 22 3.10 Data page ......................................................................................................................................................... 23 3.11 Tiered storage ................................................................................................................................................... 24 3.12 Tier redundancy and RAID ............................................................................................................................... 25 3.13 Tier redundancy and media type ...................................................................................................................... 27 3.14 RAID stripe width .............................................................................................................................................. 27 3.15 RAID penalty ..................................................................................................................................................... 30 3.16 Data Progression .............................................................................................................................................. 31 3 Dell EMC SC Series: Oracle Best Practices | CML1114 Table of contents 3.17 Data Progression pressure reports ................................................................................................................... 33 3.18 Volume distribution reports ............................................................................................................................... 34 3.19 Storage profiles ................................................................................................................................................. 35 3.20 Snapshot profiles .............................................................................................................................................. 39 3.21 Snapshots (Replays) ........................................................................................................................................ 41 3.22 Consistent snapshot profiles and Oracle .......................................................................................................... 46 3.23 Using Data Progression and snapshots ........................................................................................................... 48 3.24 SC Series cache settings ................................................................................................................................. 48 3.25 Creating volumes (LUNs) in DSM .................................................................................................................... 49 3.25.1 Scanning devices in PowerPath environments ............................................................................................ 53 3.25.2 Scanning devices in non-PowerPath environments ..................................................................................... 53 3.26 Preallocating storage ........................................................................................................................................ 54 3.27 Volume cache settings ..................................................................................................................................... 57 3.28 Data reduction with deduplication and compression ........................................................................................ 58 4
Recommended publications
  • Pete's All Things Sun (PATS): the State Of
    We are in the midst of a file sys - tem revolution, and it is called ZFS. File sys- p e t e R B a e R G a Lv i n tem revolutions do not happen very often, so when they do, excitement ensues— Pete’s all things maybe not as much excitement as during a political revolution, but file system revolu- Sun (PATS): the tions are certainly exciting for geeks. What are the signs that we are in a revolution? By state of ZFS my definition, a revolution starts when the Peter Baer Galvin (www.galvin.info) is the Chief peasants (we sysadmins) are unhappy with Technologist for Corporate Technologies, a premier the status quo, some group comes up with systems integrator and VAR (www.cptech.com). Be- fore that, Peter was the systems manager for Brown a better idea, and the idea spreads beyond University’s Computer Science Department. He has written articles and columns for many publications that group and takes on a life of its own. Of and is coauthor of the Operating Systems Concepts course, in a successful revolution the new and Applied Operating Systems Concepts textbooks. As a consultant and trainer, Peter teaches tutorials idea actually takes hold and does improve and gives talks on security and system administra- tion worldwide. the peasant’s lot. [email protected] ;login: has had two previous articles about ZFS. The first, by Tom Haynes, provided an overview of ZFS in the context of building a home file server (;login:, vol. 31, no. 3). In the second, Dawidek and McKusick (;login:, vol.
    [Show full text]
  • The Title Title: Subtitle March 2007
    sub title The Title Title: Subtitle March 2007 Copyright c 2006-2007 BSD Certification Group, Inc. Permission to use, copy, modify, and distribute this documentation for any purpose with or without fee is hereby granted, provided that the above copyright notice and this permission notice appear in all copies. THE DOCUMENTATION IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS DOCUMENTATION INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CON- SEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEG- LIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS DOCUMENTATION. NetBSD and pkgsrc are registered trademarks of the NetBSD Foundation, Inc. FreeBSD is a registered trademark of the FreeBSD Foundation. Contents Introduction vii 1 Installing and Upgrading the OS and Software 1 1.1 Recognize the installation program used by each operating system . 2 1.2 Recognize which commands are available for upgrading the operating system 6 1.3 Understand the difference between a pre-compiled binary and compiling from source . 8 1.4 Understand when it is preferable to install a pre-compiled binary and how to doso ...................................... 9 1.5 Recognize the available methods for compiling a customized binary . 10 1.6 Determine what software is installed on a system . 11 1.7 Determine which software requires upgrading . 12 1.8 Upgrade installed software . 12 1.9 Determine which software have outstanding security advisories .
    [Show full text]
  • Iscsi存储和存储多路径介绍 综合产品支持部——李树兵 01 Iscsi存储介绍
    iSCSI存储和存储多路径介绍 综合产品支持部——李树兵 01 iSCSI存储介绍 02 Linux DM multipath(多路径)介绍 01 iSCSI存储介绍 02 Linux DM multipath(多路径)介绍 SCSI(Small Computer System Interface)历史 • SISI小型计算机系统接口技术是存储设备最基本的标准协议,但是他通常需要设备互相靠近并用SCSI总 线连接。 • SCSI-1 • 1986年ANSI标准,X3.131-1986 • SCSI-2 • 1994年ANSI标准,X3.131-1994 • SCSI-3 • 发展到SCSI-3,已经过于复杂,不适合作为单独的一个标准;在某次修订中,T10委员会决定把 SCSI分为更小的单元;并且将某些单元的维护工作移交给其他组织。SCSI-3是这些子标准的集合, 表示第三代SCSI。 • iSCSI属于SCSI-3的传输协议层(类似于FCP),由IETF维护。 • 目前还没有SCSI-4 SCSI-3架构模型 Architecture Model 特定设备命令集 Device-Type Specific Command Sets 架构模型 基础命令集 Shared Command Set SCSI传输协议 SCSI Transport Protocols 物理连接 Interconnects 特定设备命令集:包括磁盘设备的“SCSI块命令(SCSI Block Commands)”等 基础命令集:所有SCSI设备都必须实现的“基础命令(SCSI Primary Commands)” SCSI传输协议:譬如iSCSI,FCP 物理连接:譬如光纤通道,internet 架构模型:定义了SCSI系统模型和各单元的功能分工 SCSI通讯模型 target initiator 任务分发器 SCSI SCSI通道 SCSI port port 逻辑单元 客户端 任务管理器 服务器 见下页的概念介绍 iSCSI正是SCSI通道的一种 SCSI主要实体介绍 • SCSI是客户端-服务器架构 • 在SCSI术语里,客户端叫initiator,服务器叫target • Initiator通过SCSI通道向target发送请求,target通过SCSI通道向initiator发送响应 • SCSI通道连接的是SCSI Port,SCSI initiator port和SCSI target port • 所以initiator至少必须包括一个SCSI Port,和一个能发起请求的客户端 • 在SCSI里,target的概念比较麻烦(可能是历史原因),它并很与initiator对应 • Target需要包括一个SCSI port,任务分发器和逻辑单元 • SCSI port用来连接SCSI通道,任务分发器负责将客户端的请求分到到适当的逻辑单元,而逻 辑单元才是真正处理任务的实体 • 通常一个逻辑单元都支持多任务环境,所以需要包含一个任务管理器和真正响应请求的服务器 • Initiator用一种叫做CDB(Command Descriptor Blocks)的数据结构封装请求 分布式SCSI通讯模型 Initiator 设备 Target 设备 • Initiator的应用层封装好SCSI SCSI应用 应用协议 SCSI应用 CDB后,调用SCSI传输协议接 口…… 传输协议接口 • Target的应用层收到SCSI CDB后, 根据CDB内容进行相应处理,封 SCSI传输协议 传输协议 SCSI传输协议 装好SCSI 响应后,调用SCSI传输 协议接口…… 互连协议接口 • iSCSI正是SCSI传输协议的一种
    [Show full text]
  • Performance and Scalability of a Sensor Data Storage Framework
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Aaltodoc Publication Archive Aalto University School of Science Degree Programme in Computer Science and Engineering Paul Tötterman Performance and Scalability of a Sensor Data Storage Framework Master’s Thesis Helsinki, March 10, 2015 Supervisor: Associate Professor Keijo Heljanko Advisor: Lasse Rasinen M.Sc. (Tech.) Aalto University School of Science ABSTRACT OF Degree Programme in Computer Science and Engineering MASTER’S THESIS Author: Paul Tötterman Title: Performance and Scalability of a Sensor Data Storage Framework Date: March 10, 2015 Pages: 67 Major: Software Technology Code: T-110 Supervisor: Associate Professor Keijo Heljanko Advisor: Lasse Rasinen M.Sc. (Tech.) Modern artificial intelligence and machine learning applications build on analysis and training using large datasets. New research and development does not always start with existing big datasets, but accumulate data over time. The same storage solution does not necessarily cover the scale during the lifetime of the research, especially if scaling up from using common workgroup storage technologies. The storage infrastructure at ZenRobotics has grown using standard workgroup technologies. The current approach is starting to show its limits, while the storage growth is predicted to continue and accelerate. Successful capacity planning and expansion requires a better understanding of the patterns of the use of storage and its growth. We have examined the current storage architecture and stored data from different perspectives in order to gain a better understanding of the situation. By performing a number of experiments we determine key properties of the employed technologies. The combination of these factors allows us to make informed decisions about future storage solutions.
    [Show full text]
  • IBM System Storage DS Storage Manager Version 11.2: Installation and Host Support Guide DDC MEL Events
    IBM System Storage DS Storage Manager Version 11.2 Installation and Host Support Guide IBM GA32-2221-05 Note Before using this information and the product it supports, read the information in “Notices” on page 295. This edition applies to version 11 modification 02 of the IBM DS Storage Manager, and to all subsequent releases and modifications until otherwise indicated in new editions. This edition replaces GA32-2221-04. © Copyright IBM Corporation 2012, 2015. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Figures .............. vii Using the Summary tab ......... 21 Using the Storage and Copy Services tab ... 21 Tables ............... ix Using the Host Mappings tab ....... 24 Using the Hardware tab ......... 25 Using the Setup tab .......... 26 About this document ......... xi Managing multiple software versions..... 26 What’s new in IBM DS Storage Manager version 11.20 ................ xii Chapter 3. Installing Storage Manager 27 Related documentation .......... xiii Preinstallation requirements ......... 27 Storage Manager documentation on the IBM Installing the Storage Manager packages website .............. xiii automatically with the installation wizard .... 28 Storage Manager online help and diagnostics xiv Installing Storage Manager with a console Finding Storage Manager software, controller window in Linux and AIX ........ 31 firmware, and readme files ........ xiv Installing Storage Manager packages manually .. 32 Essential websites for support information ... xv Software installation sequence ....... 32 Getting information, help, and service ..... xvi Installing Storage Manager manually ..... 32 Before you call ............ xvi Uninstalling Storage Manager ........ 33 Using the documentation ........ xvi Uninstalling Storage Manager on a Windows Software service and support ....... xvii operating system ........... 33 Hardware service and support .....
    [Show full text]
  • OS7 User's Manual
    OS7 User’s Manual N2810 Series/ N4810 Series/N5810 Series/ N4910U/N4910U PRO/N4820U N12850 Series/N16850 Series/ N8910/N12910/N12910SAS/N16910SAS Copyright and Trademark Notice Thecus and other names of Thecus products are registered trademarks of Thecus Technology Corp. Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation. Apple, iTunes and Apple OS X are registered trademarks of Apple Computers, Inc. All other trademarks and brand names are the property of their respective owners. Specifications are subject to change without notice. Copyright © 2017 Thecus Technology Corporation. All rights reserved. About This Manual All information in this manual has been carefully verified to ensure its correctness. In case of an error, please provide us with your feedback. Thecus Technology Corporation reserves the right to modify the contents of this manual without notice. Product name: Thecus OS7.0 used models Manual Version: 1.5.1 Release Date: 2017/06 Limited Warranty Thecus Technology Corporation guarantees all components of Thecus NAS products are thoroughly tested before they leave the factory and should function normally under general usage. In case of any system malfunctions, Thecus Technology Corporation and its local representatives and dealers are responsible for repair without cost to the customer if the product fails within the warranty period and under normal usage. Thecus Technology Corporation is not responsible for any damage or loss of data deemed to be caused by its products. It is highly recommended that users conduct necessary back-up practices. Check the functions that are available on your particular Thecus NAS model at: http://www.Thecus.com 2 Safety Warnings For your safety, please read and follow the following safety warnings: ● Read this manual thoroughly before attempting to set up your Thecus IP storage.
    [Show full text]
  • Computational Scalability of Large Size Image Dissemination
    Computational Scalability of Large Size Image Dissemination Rob Kooper*a, Peter Bajcsya aNational Center for Super Computing Applications University of Illinois, 1205 W. Clark St., Urbana, IL 61801 ABSTRACT We have investigated the computational scalability of image pyramid building needed for dissemination of very large image data. The sources of large images include high resolution microscopes and telescopes, remote sensing and airborne imaging, and high resolution scanners. The term ‘large’ is understood from a user perspective which means either larger than a display size or larger than a memory/disk to hold the image data. The application drivers for our work are digitization projects such as the Lincoln Papers project (each image scan is about 100-150MB or about 5000x8000 pixels with the total number to be around 200,000) and the UIUC library scanning project for historical maps from 17th and 18th century (smaller number but larger images). The goal of our work is understand computational scalability of the web-based dissemination using image pyramids for these large image scans, as well as the preservation aspects of the data. We report our computational benchmarks for (a) building image pyramids to be disseminated using the Microsoft Seadragon library, (b) a computation execution approach using hyper-threading to generate image pyramids and to utilize the underlying hardware, and (c) an image pyramid preservation approach using various hard drive configurations of Redundant Array of Independent Disks (RAID) drives for input/output operations. The benchmarks are obtained with a map (334.61 MB, JPEG format, 17591x15014 pixels). The discussion combines the speed and preservation objectives.
    [Show full text]
  • Of File Systems and Storage Models
    Chapter 4 Of File Systems and Storage Models Disks are always full. It is futile to try to get more disk space. Data expands to fill any void. –Parkinson’sLawasappliedto disks 4.1 Introduction This chapter deals primarily with how we store data. Virtually all computer systems require some way to store data permanently; even so-called “diskless” systems do require access to certain files in order to boot, run and be useful. Albeit stored remotely (or in memory), these bits reside on some sort of storage system. Most frequently, data is stored on local hard disks, but over the last few years more and more of our files have moved “into the cloud”, where di↵erent providers o↵er easy access to large amounts of storage over the network. We have more and more computers depending on access to remote systems, shifting our traditional view of what constitutes a storage device. 74 CHAPTER 4. OF FILE SYSTEMS AND STORAGE MODELS 75 As system administrators, we are responsible for all kinds of devices: we build systems running entirely without local storage just as we maintain the massive enterprise storage arrays that enable decentralized data replication and archival. We manage large numbers of computers with their own hard drives, using a variety of technologies to maximize throughput before the data even gets onto a network. In order to be able to optimize our systems on this level, it is important for us to understand the principal concepts of how data is stored, the di↵erent storage models and disk interfaces.Itisimportanttobeawareofcertain physical properties of our storage media, and the impact they, as well as certain historic limitations, have on how we utilize disks.
    [Show full text]
  • A Secure, Reliable and Performance-Enhancing Storage Architecture Integrating Local and Cloud-Based Storage
    Brigham Young University BYU ScholarsArchive Theses and Dissertations 2016-12-01 A Secure, Reliable and Performance-Enhancing Storage Architecture Integrating Local and Cloud-Based Storage Christopher Glenn Hansen Brigham Young University Follow this and additional works at: https://scholarsarchive.byu.edu/etd Part of the Electrical and Computer Engineering Commons BYU ScholarsArchive Citation Hansen, Christopher Glenn, "A Secure, Reliable and Performance-Enhancing Storage Architecture Integrating Local and Cloud-Based Storage" (2016). Theses and Dissertations. 6470. https://scholarsarchive.byu.edu/etd/6470 This Thesis is brought to you for free and open access by BYU ScholarsArchive. It has been accepted for inclusion in Theses and Dissertations by an authorized administrator of BYU ScholarsArchive. For more information, please contact [email protected], [email protected]. A Secure, Reliable and Performance-Enhancing Storage Architecture Integrating Local and Cloud-Based Storage Christopher Glenn Hansen A thesis submitted to the faculty of Brigham Young University in partial fulfillment of the requirements for the degree of Master of Science James Archibald, Chair Doran Wilde Michael Wirthlin Department of Electrical and Computer Engineering Brigham Young University Copyright © 2016 Christopher Glenn Hansen All Rights Reserved ABSTRACT A Secure, Reliable and Performance-Enhancing Storage Architecture Integrating Local and Cloud-Based Storage Christopher Glenn Hansen Department of Electrical and Computer Engineering, BYU Master of Science The constant evolution of new varieties of computing systems - cloud computing, mobile devices, and Internet of Things, to name a few - have necessitated a growing need for highly reliable, available, secure, and high-performing storage systems. While CPU performance has typically scaled with Moore’s Law, data storage is much less consistent in how quickly perfor- mance increases over time.
    [Show full text]
  • Jupiter® Callisto
    ® OWC Digital Jupiter® Callisto Quick Start Guide TABLE OF CONTENTS 1. INTRODUCTION ..........................................................................................................................................................................1 1.1 CONTENTS 1.2 SPECIFICATIONS (8-BAY) 1.3 SPECIFICATIONS (16-BAY) 1.4 CONNECTIONS AND COMPATIBILITY 1.5 REAR VIEW 1.6 SIDE VIEW 2. ASSEMBLY & REPLACEMENT .................................................................................................................................................4 2.2 UNIT RACK INSTALLATION & REMOVAL 2.2.1 Unit Installation 2.2.2 Unit Removal 2.3 DRIVE INSTALLATION & REMOVAL 2.3.1 Drive Installation 2.3.2 Drive Removal 2.4 POWER SUPPLY FAILURE & REPLACEMENT 2.5 FAN FAILURE 3. INITIAL SETUP ........................................................................................................................................................................... 10 3.1 CONNECTION 3.2 FIRST TIME CONFIGURATION 3.3 ACCESSING THE IPMI INTERFACE 3.4 DEFAULT SETUP 4. STORAGE CONFIGURATION ................................................................................................................................................ 12 4.1 ZFS TERMINOLOGY 4.2 STORAGE CONFIGURATION 4.2.1 Creating the Pool 4.2.2 ZFS RAID Levels 4.2.3 Optimal RAIDZ Configurations 4.2.4 Creating Datasets 4.2.5 Creating a Filesystem 4.2.6 Creating a Zvol 4.3 DRIVE IDENTIFICATION 4.4 DRIVE FAILURE & REPLACEMENT 5. USERS, GROUPS, & PERMISSIONS....................................................................................................................................
    [Show full text]
  • Australian Journal of Basic and Applied Sciences a Review On
    Australian Journal of Basic and Applied Sciences, 9(21) Special 2015, Pages: 86-91 ISSN:1991-8178 Australian Journal of Basic and Applied Sciences Journal home page: www.ajbasweb.com A Review on Raid Levels Implementation and Comparisons P. Sivakumar and K. Devi Department of Computer Science and Engineering Valliammai Engineering College Chennai, Tamilnadu-603203 ARTICLE INFO ABSTRACT Article history: Redundant array of independent disks (RAID) is the technology of grouping several Article Received: 12 January 2015 physical drives in a computer into an array that you can define as one or more logical Revised: 1 May 2015 drives. With RAID technology, data is stripped across an array of physical drives. The Accepted: 8 May 2015 data distribution scheme complements the way for the operating system which requests data. Disk arrays are used to improve performance and reliability. The improvement in Keywords: its quality depends upon the application programs that you run on the server and the RAID, mirroring, stripping, parity, RAID levels that you allocate to the logical drives. Each RAID level provides different RAID manager, Controllers. levels of fault-tolerance (data redundancy), read and write performance and utilization of physical drive capacity. Where ever, the RAID levels differ in view to the minimum and maximum number of physical drives that are supported. We are focused on data redistribution that is necessary to be performed after adding disks to the volume. In this paper we analyze some software's and implement the steps for RAID Technologies and their implementation steps. © 2015 AENSI Publisher All rights reserved. To Cite This Article: P.
    [Show full text]
  • A Primer on Raid Levels: Standard Raid Levels Defined
    A PRIMER ON RAID LEVELS: STANDARD RAID LEVELS DEFINED RAID 0: Disk striping Description: Data is striped across one or more disks in the array. Performance: Since more writers and readers can access bits of data at the same time, performance can be improved. Upside: Performance. Downside: No redundancy. One disk failure will result in lost data. Application(s): Applications that can access data from more sources than just the RAID 0 storage array. RAID 1: Disk mirroring Description: Data is written to two or more disks. No master or primary, the disks are peers. Performance: Read operations are fast since both disks are operational data can be read from both disks at the same time. Write operations, however, are slower because every write operation is done twice. Upside: If one disk fails, the second keeps running with no interruption of data availability. Downside: Cost. Requires twice as much disk space for mirroring. Application(s): Applications that require high performance and high availability including transactional applications, email, and operating systems. RAID 3: Virtual disk blocks Description: Byte-level striping across multiple disks. An additional disk is added that calculates and stores parity information. Performance: Since every write touches multiple disks, every write slows performance. Upside: Data remains fully available if a disk fails. Downside: Performance. Application(s): Good for sequential processing applications such as video imaging. RAID 4: Dedicated parity disk Description: Block-level striping across multiple disks with a cache added to increase read and write performance. Performance: Striping blocks instead of bytes and adding a cache increases performance over RAID 3.
    [Show full text]