Ten Implementations of Ptychography
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Fresnel Diffraction.Nb Optics 505 - James C
Fresnel Diffraction.nb Optics 505 - James C. Wyant 1 13 Fresnel Diffraction In this section we will look at the Fresnel diffraction for both circular apertures and rectangular apertures. To help our physical understanding we will begin our discussion by describing Fresnel zones. 13.1 Fresnel Zones In the study of Fresnel diffraction it is convenient to divide the aperture into regions called Fresnel zones. Figure 1 shows a point source, S, illuminating an aperture a distance z1away. The observation point, P, is a distance to the right of the aperture. Let the line SP be normal to the plane containing the aperture. Then we can write S r1 Q ρ z1 r2 z2 P Fig. 1. Spherical wave illuminating aperture. !!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!! 2 2 2 2 SQP = r1 + r2 = z1 +r + z2 +r 1 2 1 1 = z1 + z2 + þþþþ r J þþþþþþþ + þþþþþþþN + 2 z1 z2 The aperture can be divided into regions bounded by concentric circles r = constant defined such that r1 + r2 differ by l 2 in going from one boundary to the next. These regions are called Fresnel zones or half-period zones. If z1and z2 are sufficiently large compared to the size of the aperture the higher order terms of the expan- sion can be neglected to yield the following result. l 1 2 1 1 n þþþþ = þþþþ rn J þþþþþþþ + þþþþþþþN 2 2 z1 z2 Fresnel Diffraction.nb Optics 505 - James C. Wyant 2 Solving for rn, the radius of the nth Fresnel zone, yields !!!!!!!!!!! !!!!!!!! !!!!!!!!!!! rn = n l Lorr1 = l L, r2 = 2 l L, , where (1) 1 L = þþþþþþþþþþþþþþþþþþþþ þþþþþ1 + þþþþþ1 z1 z2 Figure 2 shows a drawing of Fresnel zones where every other zone is made dark. -
Subwavelength Resolution Fourier Ptychography with Hemispherical Digital Condensers
Subwavelength resolution Fourier ptychography with hemispherical digital condensers AN PAN,1,2 YAN ZHANG,1,2 KAI WEN,1,3 MAOSEN LI,4 MEILING ZHOU,1,2 JUNWEI MIN,1 MING LEI,1 AND BAOLI YAO1,* 1State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China 2University of Chinese Academy of Sciences, Beijing 100049, China 3College of Physics and Information Technology, Shaanxi Normal University, Xi’an 710071, China 4Xidian University, Xi’an 710071, China *[email protected] Abstract: Fourier ptychography (FP) is a promising computational imaging technique that overcomes the physical space-bandwidth product (SBP) limit of a conventional microscope by applying angular diversity illuminations. However, to date, the effective imaging numerical aperture (NA) achievable with a commercial LED board is still limited to the range of 0.3−0.7 with a 4×/0.1NA objective due to the constraint of planar geometry with weak illumination brightness and attenuated signal-to-noise ratio (SNR). Thus the highest achievable half-pitch resolution is usually constrained between 500−1000 nm, which cannot fulfill some needs of high-resolution biomedical imaging applications. Although it is possible to improve the resolution by using a higher magnification objective with larger NA instead of enlarging the illumination NA, the SBP is suppressed to some extent, making the FP technique less appealing, since the reduction of field-of-view (FOV) is much larger than the improvement of resolution in this FP platform. Herein, in this paper, we initially present a subwavelength resolution Fourier ptychography (SRFP) platform with a hemispherical digital condenser to provide high-angle programmable plane-wave illuminations of 0.95NA, attaining a 4×/0.1NA objective with the final effective imaging performance of 1.05NA at a half-pitch resolution of 244 nm with a wavelength of 465 nm across a wide FOV of 14.60 mm2, corresponding to an SBP of 245 megapixels. -
Introduction to Light Microscopy
Introduction to light microscopy A CAMDU training course Claire Mitchell, Imaging specialist, L1.01, 08-10-2018 Contents 1.Introduction to light microscopy 2.Different types of microscope 3.Fluorescence techniques 4.Acquiring quantitative microscopy data 1. Introduction to light microscopy 1.1 Light and its properties 1.2 A simple microscope 1.3 The resolution limit 1.1 Light and its properties 1.1.1 What is light? An electromagnetic wave A massless particle AND γ commons.wikimedia.org/wiki/File:EM-Wave.gif www.particlezoo.net 1.1.2 Properties of waves Light waves are transverse waves – they oscillate orthogonally to the direction of propagation Important properties of light: wavelength, frequency, speed, amplitude, phase, polarisation upload.wikimedia.org 1.1.3 The electromagnetic spectrum 퐸푝ℎ표푡표푛 = ℎν 푐 = λν 퐸푝ℎ표푡표푛 = photon energy ℎ = Planck’s constant ν = frequency 푐 = speed of light λ = wavelength pion.cz/en/article/electromagnetic-spectrum 1.1.4 Refraction Light bends when it encounters a change in refractive index e.g. air to glass www.thetastesf.com files.askiitians.com hyperphysics.phy-astr.gsu.edu/hbase/Sound/imgsou/refr.gif 1.1.5 Diffraction Light waves spread out when they encounter an aperture. electron6.phys.utk.edu/light/1/Diffraction.htm The smaller the aperture, the larger the spread of light. 1.1.6 Interference When waves overlap, they add together in a process called interference. peak + peak = 2 x peak constructive trough + trough = 2 x trough peak + trough = 0 destructive www.acs.psu.edu/drussell/demos/superposition/superposition.html 1.2 A simple microscope 1.2.1 Using lenses for refraction 1 1 1 푣 = + 푚 = physicsclassroom.com 푓 푢 푣 푢 cdn.education.com/files/ Light bends as it encounters each air/glass interface of a lens. -
Optimizing-Oncologic-FDG-PET-CT
Optimizing Oncologic FDG-PET/CT Scans to Decrease Radiation Exposure Esma A. Akin, MD George Washington University Medical Center, Washington, DC Drew A. Torigian, MD, MA University of Pennsylvania Medical Center, Philadelphia, PA Patrick M. Colletti, MD University of Southern California Medical Center, Los Angeles, CA Don C. Yoo, MD The Warren Alpert Medical School of Brown University, Providence, RI (Updated: April 2017) The development of dual-modality positron emission tomography/computed tomography (PET/CT) systems with near-simultaneous acquisition capability has addressed the limited spatial resolution of PET and has improved accurate anatomical localization of sites of radiotracer uptake detected on PET. PET/CT also allows for CT-based attenuation correction of the emission scan without the need for an external positron-emitting source for a transmission scan. This not only addresses the limitations of the use of noisy transmission data, therefore improving the quality of the attenuation-corrected emission scan, but also significantly decreases scanning time. However, this comes at the expense of increased radiation dose to the patient compared to either PET or CT alone. Optimizing PET protocols The radiation dose results both from the injected radiotracer 18F-2-fluoro-2-deoxy-D-glucose (FDG), which is ~7 mSv from an injected dose of 10 mCi (given the effective dose of 0.019 mSv/MBq (0.070 rem/mCi) for FDG), as well as from the external dose of the CT component, which can run as high as 25 mSv [1]. This brings the total dose of FDG-PET/CT to a range of ~8 mSv up to 30 mSv, depending on the type of study performed as well as the anatomical region and number of body parts imaged, although several recent studies have reported a typical average dose of ~14 mSv for skull base-to-thigh FDG- PET/CT examinations [2-8]. -
Highly Scalable Image Reconstruction Using Deep Neural Networks with Bandpass Filtering Joseph Y
1 Highly Scalable Image Reconstruction using Deep Neural Networks with Bandpass Filtering Joseph Y. Cheng, Feiyu Chen, Marcus T. Alley, John M. Pauly, Member, IEEE, and Shreyas S. Vasanawala Abstract—To increase the flexibility and scalability of deep high-density receiver coil arrays for “parallel imaging” [2]– neural networks for image reconstruction, a framework is pro- [6]. Also, image sparsity can be leveraged to constrain the posed based on bandpass filtering. For many applications, sensing reconstruction problem for compressed sensing [7]–[9]. With measurements are performed indirectly. For example, in magnetic resonance imaging, data are sampled in the frequency domain. the use of nonlinear sparsity priors, these reconstructions are The introduction of bandpass filtering enables leveraging known performed using iterative solvers [10]–[12]. Though effective, imaging physics while ensuring that the final reconstruction is these algorithms are time consuming and are sensitive to consistent with actual measurements to maintain reconstruction tuning parameters which limit their clinical utility. accuracy. We demonstrate this flexible architecture for recon- We propose to use CNNs for image reconstruction from structing subsampled datasets of MRI scans. The resulting high subsampling rates increase the speed of MRI acquisitions and subsampled acquisitions in the spatial-frequency domain, and enable the visualization rapid hemodynamics. transform this approach to become more tractable through the use of bandpass filtering. The goal of this work is to enable Index Terms—Magnetic resonance imaging (MRI), Compres- sive sensing, Image reconstruction - iterative methods, Machine an additional degree of freedom in optimizing the computation learning, Image enhancement/restoration(noise and artifact re- speed of reconstruction algorithms without compromising re- duction). -
The-Pathologists-Microscope.Pdf
The Pathologist’s Microscope The Pathologist’s Microscope Rudolf Virchow, the father of Pathology, had available to him wonderful microscopes during the 1850’s to 1880’s, but the one you have now is far better. Your microscope is the most highly perfected of all scientific instruments. These brief notes on alignment, the objective lens, the condenser, and the eyepieces are what you need to know to get the most out of your microscope and to feel comfortable using it. Figure 1 illustrates the important parts of a generic modern light microscope. Figure 1 - Parts of the Microscope UNC Pathology & Lab Med, MSL, July 2013 1 The Pathologist’s Microscope Alignment August Köhler, in 1870, invented the method for aligning the microscope’s optical system that is still used in all modern microscopes. To get the most from your microscope it should be Köhler aligned. Here is how: 1. Focus a specimen slide at 10X. 2. Open the field iris and the condenser iris. 3. Observe the specimen and close the field iris until its shadow appears on the specimen. 4. Use the condenser focus knob to bring the field iris into focus on the specimen. Try for as sharp an image of the iris as you can get. If you can’t focus the field iris, check the condenser for a flip-in lens and find the configuration that lets you see the field iris. You may also have to move the field iris into the field of view (step 5) if it is grossly misaligned. 5.Center the field iris with the condenser centering screws. -
To Take Into Consideration the Propriety Of
his was the subject for discussion amongst the seventeen microscopists who met at Edwin Quekett’s house No 50 Wellclose Square, in the Borough of Stepney, East London on 3rd September 1839. It was resolved that such a society be formed Tand a provisional committee be appointed to carry this resolution into effect. The appointed provisional committee of seven were to be responsible for the formation of our society, they held meetings at their homes and drew up a set of rules. They adopted the name ‘Microscopical Society of London’ and arranged a public meeting on the 20th December 1839 at the rooms of the Horticultural Society, 21 Regent Street. Where a Nathaniel Bagshaw Ward © National Portrait Gallery, London President, Treasurer and Secretary were elected, the provisional committee also selected the size of almost airtight containers. Together with George 3 x 1 inch as a standard for glass slides. Loddiges, he saw the potential benefit of protection from sea air damage allowing the transport of plants Each of the members of the provisional committee between continents. This Ward published in 1834 had their own background which we have briefly and eventually his cases enabled the introduction described on the following pages, as you will see of the tea plant to Assam from China and rubber they are a diverse range of professionals. plants to Malaysia from South America. His glass plant cases allowed the growth of orchids and ferns in the Victorian home and in 1842 he wrote a book on the subject. However glass was subject to a tax making cases expensive so Ward lobbied successfully for its repeal in 1845. -
The Scientific Legacy of Antoni Van Leeuwenhoek
196 Chapter 12 Chapter 12 The Scientific Legacy of Antoni Van Leeuwenhoek This final chapter discusses some of the developments in science on which Antoni van Leeuwenhoek left his mark from his death to the beginning of the 21st century. It will review the influence of his work and listen for the echoes of his name almost three hundred years after his death. Figure 12.1 Nineteenth-century microscope by George Adams with eyepiece, objective, various attachments and a mirror to illuminate the specimen © Koninklijke Brill NV, Leiden, 2016 | doi 10.1163/9789004304307_013 The Scientific Legacy of Antoni Van Leeuwenhoek 197 Microscopy Microscopes have become increasingly complex and more versatile, but much easier to use, since the time of Van Leeuwenhoek. Single-lens microscopes went out of use in the 18th century, when compound microscopes with at least two lenses ‒ an eyepiece and an objective ‒ became the norm. Many innovations came from England. Firstly, the illumination of speci- mens was improved. During Van Leeuwenhoek’s lifetime, John Marshall (1663–1725) had developed a simple illumination system using a mirror attached to the foot of the microscope. John Cuff (1708–1772) used an extra lens, a condenser, in 1744 to concentrate light on the specimen. In 1755, George Adams (1720–1773) developed a microscope with a rotating wheel holding objectives with different powers of magnification. Sliding holders in which a variety of specimens could be mounted at one time can be traced back to the rotating holders on the single-lensed microscopes used by Christiaan Huygens and J. De Pouilly (or Depovilly) in the 1670s, and were developed for use with compound microscopes. -
Huygens Principle; Young Interferometer; Fresnel Diffraction
Today • Interference – inadequacy of a single intensity measurement to determine the optical field – Michelson interferometer • measuring – distance – index of refraction – Mach-Zehnder interferometer • measuring – wavefront MIT 2.71/2.710 03/30/09 wk8-a- 1 A reminder: phase delay in wave propagation z t t z = 2.875λ phasor due In general, to propagation (path delay) real representation phasor representation MIT 2.71/2.710 03/30/09 wk8-a- 2 Phase delay from a plane wave propagating at angle θ towards a vertical screen path delay increases linearly with x x λ vertical screen (plane of observation) θ z z=fixed (not to scale) Phasor representation: may also be written as: MIT 2.71/2.710 03/30/09 wk8-a- 3 Phase delay from a spherical wave propagating from distance z0 towards a vertical screen x z=z0 path delay increases quadratically with x λ vertical screen (plane of observation) z z=fixed (not to scale) Phasor representation: may also be written as: MIT 2.71/2.710 03/30/09 wk8-a- 4 The significance of phase delays • The intensity of plane and spherical waves, observed on a screen, is very similar so they cannot be reliably discriminated – note that the 1/(x2+y2+z2) intensity variation in the case of the spherical wave is too weak in the paraxial case z>>|x|, |y| so in practice it cannot be measured reliably • In many other cases, the phase of the field carries important information, for example – the “history” of where the field has been through • distance traveled • materials in the path • generally, the “optical path length” is inscribed -
Arxiv:1707.05927V1 [Physics.Med-Ph] 19 Jul 2017
Medical image reconstruction: a brief overview of past milestones and future directions Jeffrey A. Fessler University of Michigan July 20, 2017 At ICASSP 2017, I participated in a panel on “Open Problems in Signal Processing” led by Yonina Eldar and Alfred Hero. Afterwards the editors of the IEEE Signal Processing Magazine asked us to write a “perspectives” column on this topic. I prepared the text below but later found out that equations or citations are not the norm in such columns. Because I had already gone to the trouble to draft this version with citations, I decided to post it on arXiv in case it is useful for others. Medical image reconstruction is the process of forming interpretable images from the raw data recorded by an imaging system. Image reconstruction is an important example of an inverse problem where one wants to determine the input to a system given the system output. The following diagram illustrates the data flow in an medical imaging system. Image Object System Data Images Image −−−−−→ −−−→ reconstruction −−−−−→ → ? x (sensor) y xˆ processing (estimator) Until recently, there have been two primary methods for image reconstruction: analytical and iterative. Analytical methods for image reconstruction use idealized mathematical models for the imaging system. Classical examples are the filtered back- projection method for tomography [1–3] and the inverse Fourier transform used in magnetic resonance imaging (MRI) [4]. Typically these methods consider only the geometry and sampling properties of the imaging system, and ignore the details of the system physics and measurement noise. These reconstruction methods have been used extensively because they require modest computation. -
Simple and Open 4F Koehler Transmitted Illumination System for Low- Cost Microscopic Imaging and Teaching
Simple and open 4f Koehler transmitted illumination system for low- cost microscopic imaging and teaching Jorge Madrid-Wolff1, Manu Forero-Shelton2 1- Department of Biomedical Engineering, Universidad de los Andes, Bogota, Colombia 2- Department of Physics, Universidad de los Andes, Bogota, Colombia [email protected] ORCID: JMW: https://orcid.org/0000-0003-3945-538X MFS: https://orcid.org/0000-0002-7989-0311 Any potential competing interests: NO Funding information: 1) Department of Physics, Universidad de los Andes, Colombia, 2) Colciencias grant 712 “Convocatoria Para Proyectos De Investigación En Ciencias Básicas“ 3) Project termination grant from the Faculty of Sciences, Universidad de los Andes, Colombia. Author contributions: JMW Investigation, Visualization, Writing (Original Draft Preparation) MFS Conceptualization, Funding Acquisition, Methodology, Supervision, Writing(Original Draft Preparation) 1 Title Simple and open 4f Koehler transmitted illumination system for low-cost microscopic imaging and teaching Abstract Koehler transillumination is a powerful imaging method, yet commercial Koehler condensers are difficult to integrate into tabletop systems and make learning the concepts of Koehler illumination difficult. We propose a simple 4f Koehler illumination system that offers advantages with respect to building simplicity, cost and compatibility with tabletop systems, which can be integrated with open source Light Sheet Fluorescence Microscopes (LSFMs). With those applications in mind as well as teaching, we provide -
Positron Emission Tomography with Three-Dimensional Reconstruction
SE9700024 Positron Emission Tomography with Three-dimensional reconstruction Kjell Erlandsson Radiation Physics Department The Jubileum Institute Lund University Sweden 1996 Doctoral Dissertation 1996 Radiation Physics Department The Jubileum Institute Lund University Printed in Sweden by KF-Sigma, Lund, 1996 ISBN 91-628-2189-X Copyright © Kjell Erlandsson (pages 1-67) All rights reserved "I'm guided by the beauty of our weapons." Leonard Cohen LIST OF ORIGINAL PAPERS This thesis is based on the following papers, which will be referred to in the text by their Roman numerals: I. Sandell A, Erlandsson K, Ohlsson T, Strand S-E, "A PET Scanner Based on Rotating Scintillation Cameras: Development and Experience", submitted to J Nucl Med, 1996. II. Erlandsson K, Strand S-E, "A New Approach to Three-Dimensional Image Reconstruction in PET", IEEE Trans Nucl Sci, 39:1438-1443, 1992. III. Erlandsson K, Esser PD, Strand S-E, van Heertum RL, "3D Reconstruction for a Multi-Ring PET Scanner by Single-Slice Rebinning and Axial Deconvolution", Phys Med Biol, 39:619-629, 1994. IV. Erlandsson K, Strand S-E, "3D Reconstruction for 2D PET", submitted to Nucl Instr Meth A, 1996. V. Sandell A, Erlandsson K, Bertenstam L, "A Scanner for Positron Emission Mammography", submitted to Phys Med Biol, 1996. ABSTRACT In this thesis, the developments of two different low-cost scanners for positron emission tomography (PET), based on 3D acquisition, are presented. 3D reconstruction methods for these systems were also developed. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful.