Artioscad 16 Release Notes

Total Page:16

File Type:pdf, Size:1020Kb

Artioscad 16 Release Notes ARTIOSCAD 16 RELEASE NOTES ArtiosCAD 16 Release Notes Release Contents ArtiosCAD 16 is new Esko Suite release. The ArtiosCAD 16 shipment package contains: Artioscad installation media Artioscad release notes (this document) System Requirements document (PDF format) Please contact you local Esko CAD support if you have any questions. In the U.S., this number is (877) 363 4091. Problem fixes: Customer reported fixes ACAD-3110 3D export problem (actually resolved in 14.1.3) ACAD-3117 Artios CAD 3D folding duplicate items... regresion test saving fold angles in A3D and ARD and opening subsequent times ACAD-3126 Create any box with flaps and fold it on 3D and export as STEP with single body option off ACAD-3208 Linienprobleme mit pdf ACAD-3277 can't open STP, shows error ACAD-3278 Problem with "Duplicate designs" in ArtiosCAD 3D ACAD-3316 Probleme mit Print Registration Marks ACAD-3332 Customer Problem: Special rules disappear in laser output if die-split is used and rule labels ACAD-3337 ArtiosCAD 14.1.3 Sounds ACAD-3394 TAB and ENTER keys do not work when entering a variable Important internal fixes ACAD-2853 Cad-X can crash on shutdown 1 ARTIOSCAD 16 RELEASE NOTES ACAD-3375 Since 14.1.1 CUROL in mfg does not return the proper layer #. Always returns 0 ACAD-3515 Handwriting-based font can’t outline properly Important Notes for All Users ArtiosCAD is currently a 32-bit application that will run on 64-bit machines. It is expected that ArtiosCAD will eventually migrate to being a native 64-bit application. The exact timeframe is unknown. At that time, 32-bit machines will not be supported. Esko now provides a knowledge base at http://help.esko.com/knowledgebase. This site can be used to find detailed information for ArtiosCAD and other Esko products about many support questions raised to Esko. Flexnet is the only licensing system utilized in ArtiosCAD 16. Users must be prepared to convert the licensing from the hardware key, Sentinel LM or Elan LM to Flexnet. As of Jan 2016, Esko will no longer be able to provide licenses for legacy licensing systems. If the deployed licensing for ArtiosCAD is a network license, the license server *must* be updated with the new system controller provided on the installation media unless upgrading from ArtiosCAD 16. Esko software can be downloaded from https://mysoftware.esko.com with a valid support account. User documentation and help will be available from an online Esko site. Documentation will not be available from the media. The main site is http://help.esko.com from which ArtiosCAD and other Esko product documentation is available. The ArtiosCAD help menu will bring the user to the ArtiosCAD help page. The most current Adobe®Illustrator® Esko plugins can be found at http://www.esko.com. Navigate as described below. 2 ARTIOSCAD 16 RELEASE NOTES 3 ARTIOSCAD 16 RELEASE NOTES Windows 10 has been certified for use with ArtiosCAD 16 as a standard mouse- controlled application. There are some installation limitations. See Esko ArtiosCAD knowledge base. Windows 8, 8.1 and Windows Server 2012 have been certified for use with ArtiosCAD 16 as a standard mouse-controlled application. There are Metro GUI limitations: o The application folder structure organized in previous versions of windows 8 has been flattened. There will be multiple application tiles. o There is no support for touchpads nor touchscreens and any use of gestures is purely coincidental. Windows 7 has been certified for use with ArtiosCAD 16 with limitations. o User Account Control must be disabled before using the Programs and Features control panel to modify or repair an Artioscad 7.6 installation o The 1PstP selection in the File Open preview dialog does not appear the 1PstP time. Once the user starts navigating through the list, the previews will start appearing. o Toolbars in ArtiosCAD: 4 ARTIOSCAD 16 RELEASE NOTES . When using the Aero theme, floating toolbar edges are not fully drawn. The Windows 7 snip tool can confuse toolbar location. The right side of the monitor appears to have a special function in Windows 7 and it is difficult to dock toolbars to the right side of the ArtiosCAD main window if it is maximized. An ArtiosCAD windows which is smaller than the monitor will allows docking and if the toolbar is already docked, it will stay docked when the ArtiosCAD window is maximized. o The use of AeroPeek seems to confuse USB mice and will unexpectedly move the pointer to unintended locations. o Avoid use of the Windows 7 magnify tool. o Avoid setting the Windows 7 magnification to more than 125%. Beyond this level, the tool icons look a bit fuzzy and the prompts in the dialog bars can be compressed in size as to be rendered difficult to see. The IOServer (ArtiosIO) is now supported on Windows 7 and higher since Artioscad 14. 1. This means older DataTech plotters still using the IPC controller or any device with an RS232 connection will be supported Many users have or are planning to deploy Citrix, Terminal Services (TS) environments or some other application hosting system. Esko has not officially certified ArtiosCAD for use in a Citrix or TS environment, however, Esko does not prevent its use as long as the customer accepts responsibility for deployment and support of the environment. Esko has verified that ArtiosCAD 16 can run as a Citrix or Terminal Services client and has licensed ArtiosCAD 16 appropriately, however, there are some limitations, including but not limited to: Flexnet network licensing must be used. License reservation or denial via floating license servers is not supported. Graphics cards are installed on a Citrix or TS server and ArtiosCAD 3D uses the server card for 3D rendering. The performance of many concurrent 3D users is unknown. The exact server specifications (example, memory, processor) for a given set of clients is unknown. There are essentially no user defaults, since every Citrix or TS client is running from the same Citrix server. There have been reports that access to local devices like hard drives or printers can freeze the machine. It is unknown if these issues have been addressed in newer versions of Citrix. The HASP key used for the Alma PowerNest software in the ArtiosCAD rubbering layout can not be recognized by Citrix or TS and must be used on a client not connected to the Citrix server. 64-bit Citrix has not been tested in any way. 5 ARTIOSCAD 16 RELEASE NOTES Many users are planning to deploy VMWare ESX-based solutions, Hyper V (Windows Server Virtualization), Citrix XenServer or other hypervisor technology. Esko has not officially certified ArtiosCAD for use in this environment, however, Esko does not prevent its use as long as the customer accepts responsibility for deployment and support of the environment. Artioscad 16 has been certified for VMware Fusion v5.x for the Mac 10.6 . Intensive 3D is not recommended for VMWare fusion. The rendering mode should be Direct 3D, not OpenGL. For native windows applications, the 3D Rendering Option is recommended to be set to OpenGL for full 3D functionality. Use of OpenGL for Bitmaps should also be enabled. 3D graphics cards… newer computers often come with some form of switchable graphics technology. This means that there are two or more video cards that switch off doing rendering duties on the system. Because of this, it is entirely possible that ArtiosCAD will be run using the low end, power saving chip. This drastically lowers performance, and may introduce issues when working within ArtiosCAD 3D. It is sometimes also possible that the current chip changes, which can lead to all sorts of stability issues. It is recommended that the user go to the control panel controlling the graphics cards (NVidia Control Panel or AMD Catalyst Control Center) and create a profile for ArtiosCAD so it will use the high end chip always. This is an example and is for windows 7. 6 ARTIOSCAD 16 RELEASE NOTES A number of rendering issues with NVidia cards and openGL have been raised. Changes were made to what is believed to be an improvement in the error handling of newer NVidia cards particularly those with dual graphic cards. • The default SA password for the SQL Express database will be XXXXXX. InstallShield/SQL Express will adopt the Windows Domain security policy. If this policy is set to ‘strong authentication’, administrative passwords must conform to the policy. XXXXXX Is a strong password. This password may be changed by the DBA for security purposes, but until further notice, please note this password will need to be restored to XXXXXX when installing future versions of Artioscad. Also note, please do not use ‘%’ as character in the password. This restriction is due to the scripting mechanism used to automatically build a database. • Since its inception, Artioscad has provided a database schema that has always been backwards compatible with previous versions of Artioscad and 3rd party applications. An ArtiosCAD enterprise edition has now been released and utilizes a new database backend (WebCenter). It is expected that the database functionality for the conventional ArtiosCAD edition will be frozen at its current level. New design 7 ARTIOSCAD 16 RELEASE NOTES functionality will continue to be added. It is expected that a single database edition will be created in the future. Artioscad development is making preparations for moving to double precision float values. This would potentially result in a file that is not backwards compatible with earlier versions. The timing of this change is unknown. We do expect that workspaces created in earlier versions would be forwards compatible. PCIQ fonts will begin to be phased out in the 3D module.
Recommended publications
  • Artioscad 16 and Artioscad Enterprise 16 Client System Requirements
    ArtiosCAD 16 and ArtiosCAD Enterprise 16 Client System Requirements The following are the minimum system requirements for ArtiosCAD 16. Exceeding these requirements will in most cases lead to a performance increase. Running ArtiosCAD on a system that does not meet System Requirements these requirements is not supported. Applies to ArtiosCAD Minimum requirements ArtiosCAD Enterprise CAD-X Minimum System Requirements for ArtiosCAD 16 Version 16 Type Minimum Recom mended Last revised 08-Mar-2017 Processo ArtiosCAD 2D Intel® Core r type 2 Duo: 2.4 and GHz, 2.4 Useful Links speed GHz Software downloads: mysoft ArtiosCAD 3D - Animation 2.4 GHZ - ware.esko.com 64 bit Software installation: ArtiosC ArtiosCAD 3D - 3D Data Exchange 3.0 GHz - AD 14.1 installation guide 64 bit RAM 4 GB minimum 4 GB 8 GB Software installation: ArtiosC for 3D AD Enterprise 14.1 Data installation guide Exchan ge Available ArtiosCAD installation 10 GB (+1 hard GB on C drive drive) space ArtiosCAD Enterprise Client +100 GB +200 GB Graphics ArtiosCAD 3D requires a display adapter/graphics card that is OpenGL and 1 GB card and Direct-X compliant. video drivers If CAD-X is used in a server environment, the graphics card must still match the above memory requirement. Server-class machines generally do not have high quality or memory graphics cards as standard issue. Minimum 1024 x 768 resolution at 16-bit color depth. screen resolution I/O Ports 1 USB and input devices Internet TCP/IP v4 required. TCP/IP v6 is not supported. connection ArtiosCAD Enterprise client communicating with central site at WAN speeds T1 (1.544 T3 (44 Mbits/s) Mbits/s) HTTP at high QOS Virtualiza Parallels Desktop or VMware® Fusion® is supported, but please be aware tion that Esko doesn't test all combinations of Mac® OS X and Parallels Desktop /VMware® Fusion®.
    [Show full text]
  • Artioscad 14.1.1 and Artioscad Enterprise 14.1.1 Client System Requirements
    ArtiosCAD 14.1.1 and ArtiosCAD Enterprise 14.1.1 Client System Requirements The following are the minimum system requirements for ArtiosCAD 14.1.1. Exceeding these requirements will in most cases lead to a performance increase. Running ArtiosCAD on a system that System Requirements does not meet these requirements is not supported. Applies to ArtiosCAD Windows 10 ArtiosCAD Enterprise Windows 10 is not supported in the 14.1.1 version. CAD-X Version 14.1.1 Minimum requirements Last revised 13-Oct-2015 Minimum System Requirements for ArtiosCAD 14 Useful Links Proces Intel® Core 2 Duo: 2.4 GHz, 2.4 GHz, required. Software downloads: mysoft sor ware.esko.com type To fully take advantage of the 3D Data Exchange module, x86 64-bit processors are and recommended, especially for importing files of over 100 MB in size. You will need to Software installation: ArtiosC speed consider the 64-bit processors for future releases of ArtiosCAD. AD 14.1 installation guide ArtiosCAD is still a 32-bit application. All other uses other than 3D Data Exchange modules Software installation: ArtiosC will require at a minimum x86 32-bit processor. ArtiosCAD will still run on a 64-bit processor AD Enterprise 14.1 but as a 32-bit application. installation guide RAM 4 GB minimum Availab Contents le hard You need at least 5 GB free disk space for the ArtiosCAD application and 500 MB free drive disk space on the system partition. space If you are using the ArtiosCAD Enterprise client, please reserve an additional 30 GB for Minimum requirements the ArtiosCAD application, including the local cache.
    [Show full text]
  • Artioscad 18 and Artioscad Enterprise 18 Client System Requirements
    ArtiosCAD 18 and ArtiosCAD Enterprise 18 Client System Requirements The following are the minimum system requirements for ArtiosCAD 18. Exceeding these requirements will in most cases lead to a performance increase. Running ArtiosCAD on a system that does not meet System Requirements these requirements is not supported. Applies to ArtiosCAD Minimum requirements ArtiosCAD Enterprise CAD-X Minimum System Requirements for ArtiosCAD 18 Version 18 Type Minimum Recommend ed Last revised 20-May-2018 Proce ArtiosCAD 2D Intel® C ssor ore 2 type Duo: Useful Links and 2.4 speed GHz, Software downloads: mysoft 2.4 GHz ware.esko.com ArtiosCAD 3D - Animation 2.4 Software installation: ArtiosC GHZ - AD 18.0 installation guide 64 bit Software installation: ArtiosC ArtiosCAD 3D - 3D Data Exchange 3.0 GHz - AD Enterprise 18.0 64 bit installation guide RAM ArtiosCAD 4 GB ArtiosCAD 3D - 3D Data Exchange 8 GB 16G when opening files 500M-1G 16G+ on systems running many applications concurrently Availa ArtiosCAD installation 10 GB ble (+1 GB hard on C drive drive) space ArtiosCAD Enterprise Client +100 +200 GB GB Graphi ArtiosCAD 3D requires a display adapter/graphics card that is OpenGL and 1 GB 2G+ cs Direct-X compliant. card and video If CAD-X is used in a server environment, the graphics card must drivers still match the above memory requirement. Server-class machines generally do not have high quality or memory graphics cards as standard issue. Minim 1024 x 768 resolution at 16-bit color depth. um screen FHD 1920x1080 resolut WUXGA 1920x1200 ion System text scale/zoom size no more than 125%.
    [Show full text]