Switching & Controls & Pilot Lights

Selection Guide...... 754

General Purpose Relays...... 756 RV8H Series 6mm Interface Relays...... 756 RJ Series Slim Power Relays...... 759 RQ Series PCB Relays......

769 Signaling Lights RH Series Compact Power Relays...... 773 RR Series Power Relays...... 783 RU Series Universal Relays...... 790 RY/RM Series Miniature Relays...... 799 RF1V Force Guided Relays...... 810

Solid State Relays...... 819

RSC Series Solid State Relays...... 819 Relays & Sockets RSS Series Panel Mount Solid State Relays...... 822

Relays Timers Terminal Blocks

www.IDEC.com/relays Circuit Breakers

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg. 933 Selection Guide

Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 754 Selection Guide General Purpose Relays Contact Material (resistive) Contact Rating Terminal Contact Configuration Contact Material (resistive) Contact Rating Terminal Contact Configuration Appearance Page Appearance Series Page Series plating Silver-Nickel withgold 6A 30VDC/250VAC Screw 1 formC(SPDT) 4PDT DPDT 1/10HP, 240VAC 4PDT: 6A,30VDC/250VAC DPDT: 10A,30VDC/250VAC Blade orPCB DPDT, 4PDT RV8H Series Gold-Silver AlloyonSilver Silver Tin OxideIndium 756 RU Series 790 Silver-Nickel alloy DPDT: 8A,30VDC/250VAC DC/250V AC SPDT: 12A/16A,30V Blade orPCB SPDT, SPST, DPDT, DPST RJ Series 759 Selection Guide Gold platedsilver 4PDT: 5A,30VDC/240VAC RY: DPDT: 3A,30VDC/240VAC Blade orPCB DPDT, 4PDT Relays &Sockets www.IDEC.com Silver-Nickel alloy DPDT: 8A SPDT: 12A,16A PCB SPDT, DPDT RQ Series RY/RM Series 769 799 Silver 5A, 30VDC/240VAC DPDT Silver-Cadmium Oxide 1/6HP, 120VAC 1/3HP, 240VAC 10A, 30VDC/240VAC Blade orPCB SPDT, DPDT, 3PDT, 4PDT RH Series 773 Silver alloy 6A 250VDC 6A, 250VAC 4PDT or6PDT Silver 1/4HP, 120VAC 1/3HP, 240VAC 10A, 30VDC/240VAC Pin orBlade SPDT, DPDT, 3PDT RF1V Series 810 RR Series 783 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 755 Selection Guide Selection USA & Canada • 790 822 Selection Guide con’t Guide Selection RU42 Series RY2KS Series RSS Series Relays & Sockets & Relays DPDT Blade 3A, 30V DC 3A, 240V AC gold-plated Silver, 4PDT Blade or PCB 3A 250V AC/30V DC Gold Silver Alloy on Silver 1 Form A (SPST-NO) 10A, 25A, 50A, 75A, 90A 48 - 660V AC 800-262-IDEC (4332) Dual SCR (zero crossing) visit www.IDEC.com/relays 759 819 RJ22 Series RR2KP Series RSC Series 1 Form A (SPST-NO) 20A, 30A, 45A 48 - 600V AC DPDT Pin 10A, 30V DC 10A, 240V AC Silver DPDT Blade or PCB 1A 250V AC/30V DC Gold clad Output Configuration Output Rating Output Page Series Appearance Page Appearance Contact Configuration Terminal Contact Rating (resistive) Contact Material Series Page Series Appearance Contact Configuration Terminal Contact Rating (resistive) Contact Material Solid State Relays Latching Relays Bifurcated Contacts Relays Bifurcated RV8H

Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 756 RV8H Replacement Parts Complete PartNumbers(&Socket) DC AC/ DC Coil Voltage Key features:

Screw Terminals • • • • • • • • • • • • • • RoHS compliant 1500VA maximumswitchingpower 400V ACmaximumswitchingvoltage Reverse Polarityprotected High dielectricstrengthandimpulsewithstandvoltages Wide inputvoltagerange:6to240V Lever foreasylockingandremovalofrelay Universal AC/DCsocketwithbuilt-insurgesuppressionandgreenLED Spring clampterminals Universal screwterminals(flatandPhillips) Pre-assembled relayandDINmountsocket Gold-plated contacts Only 70mminheightfromDINrail Space-saving 6mmwidth Standard stockmodelsinbold. 220V -240V 110V -125V 60V 48V 24V 18V 12V 24V 18V 12V 9V 6V RV8H-L-AD220 RV8H-L-AD110 RV8H-L-AD60 RV8H-L-AD48 RV8H-L-AD24 RV8H-L-AD18 RV8H-L-AD12 RV8H-L-D24 RV8H-L-D18 RV8H-L-D12 RV8H-L-D9 RV8H-L-D6 Number Complete Part RV8H-L-AD220 RV8H-L-AD110 RV8H-L-AD60 RV8H-L-AD48 RV8H-L-AD24 RV8H-L-AD18 RV8H-L-AD12 RV8H-L-D24 RV8H-L-D18 RV8H-L-D12 RV8H-L-D9 RV8H-L-D6 minal Screw Ter (Standard Stockinbold) SV1H-07L-4 SV1H-07L-3 SV1H-07L-2 SV1H-07L-1 SV1H-07L-5 Part Number Applicable Socket - Part Number RV8H-S-AD220 RV8H-S-AD110 RV8H-S-AD60 RV8H-S-AD48 RV8H-S-AD24 RV8H-S-AD18 RV8H-S-AD12 RV8H-S-D24 RV8H-S-D18 RV8H-S-D12 RV8H-S-D9 RV8H-S-D6 Terminal Spring Clamp

RV8H Series 6mmInterfaceRelays RV1H-G-D60 RV1H-G-D60 RV1H-G-D60 RV1H-G-D48 RV1H-G-D24 RV1H-G-D18 RV1H-G-D12 RV1H-G-D24 RV1H-G-D18 RV1H-G-D12 RV1H-G-D9 RV1H-G-D5 Part Number Applicable Relay Accessories Spacer (circuitseparator) Screwdriver Item Jumper (20combs Note: Whenusingacutjumper, pleaseuseaspaceronthecut 2. 1. side. Foradditionalinformationseeinstructionsheet. Width ofspacer:2mm needed simplycutofftheexcesspoints. Jumper combscomewith20points,ifshorterlengthsare Part Numbers Relays &Sockets www.IDEC.com 1 Spring Clamp Terminals ) RV8H-S-AD220 RV8H-S-AD110 RV8H-S-AD60 RV8H-S-AD48 RV8H-S-AD24 RV8H-S-AD18 RV8H-S-AD12 RV8H-S-D24 RV8H-S-D18 RV8H-S-D12 RV8H-S-D9 RV8H-S-D6 Number Complete Part 2 RV relayandSVsocket) (when usingcombinationof Blue Gray Black Blue – Color SV9Z-J20S SV9Z-J20W SV9Z-J20B BC1S-SD0 SV9Z-SA2W Part Number SV1H-07LS-4 SV1H-07LS-3 SV1H-07LS-2 SV1H-07LS-1 SV1H-07LS-5 Part Number Applicable Socket

Marking Plates 2. 1. Item Each unithas10pieces(markingplates). In placeofjinsertorientationcode:V=Vertical, H=Horizontal RV1H-G-D60 RV1H-G-D60 RV1H-G-D60 RV1H-G-D48 RV1H-G-D24 RV1H-G-D18 RV1H-G-D12 RV1H-G-D24 RV1H-G-D18 RV1H-G-D12 RV1H-G-D9 RV1H-G-D5 Part Number Applicable Relay Horizontal Orientation Vertical Orientation SV9Z-PW10-jAC SV9Z-PW10-jGROUND SV9Z-PW10-jU-Z SV9Z-PW10-jK-T SV9Z-PW10-jA-J SV9Z-PW10-j91-100 SV9Z-PW10-j81-90 SV9Z-PW10-j71-80 SV9Z-PW10-j61-70 SV9Z-PW10-j51-60 SV9Z-PW10-j41-50 SV9Z-PW10-j31-40 SV9Z-PW10-j21-30 SV9Z-PW10-j11-20 SV9Z-PW10-j1-10 SV9Z-PW10 Part Number AC GROUND U-Z K-T A-J 91-100 81-90 71-80 61-70 51-60 41 -50 31-40 21-30 11-20 1-10 blank Engraving Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 757 RV8H 1500VA, 180W 1500VA, DC 6A 250V AC 6A, 30V 6A 125VDC 400VAC, 180W 1500VA, 6VDC/10mA 0.25W 0.33W 0.2W 0.2W 0.5W 0.85W 0.2W 0.2W 0.2W 0.2W 0.25W 0.21W Power Consumption Resistive load Resistive load DC Resistive load Contact Voltage (V) Contact Voltage DC Inductive load (L/R = 56ms)

110% 110% Maximum Allowable voltage Contact Current (A) Current Contact Maximum Switching Power DC Rated Load Current Allowable Switching Allowable Switching Voltage Allowable Switching Power Minimum Applicable Load Allowable contact Allowable contact power Contact Ratings 7% min Dropout Voltage Operating Characteristics 90% max Pickup Voltage AC Resistive load USA & Canada Specifications • AC Inductive load (p. f=0.35) Contact Voltage (V) Contact Voltage 1790 12230 17910 32450 - 32900 65940 - 68570 1345 820 1550 2270 485 800 170 Circuit DC Resistance +-10% (Ω)

Relays & Sockets & Relays Contact Current (A) Current Contact Maximum Switching Power AC (3G) 2 (5G) 2 (10G) 2 800-262-IDEC (4332) 1730 11880 17600 31790 - 31890 65670 - 66070 1365 - - - - 755 - Circuit AC Resistance +-10% (Ω) NO: 49m/s NO: Frequency 10 to 55Hz, Amplitude 1.0mm NO: Frequency 10 to 55Hz, Amplitude 0.4mm NC: Frequency 10 to 55Hz, Amplitude 0.5mm NO: Frequency 10 to 55Hz, Amplitude 0.2mm NC: Frequency 10 to 55Hz, 4,000V AC for 1min 1,000V AC for 1min 980m/s Over 10,000,000 operations Over 10,000,000 operations -40 to +70°C without freezing (-40 to +55°C for RV8H-L-AD110, AD220, RV8H-S-AD110, AD220) 5 to 85% (without condensation) 30g (RV8H-L), 26g (RV8H-S) 1 pole 1 form C (SPDT) AgNi (Au plating) IP20 NC: 29.4m/s 13.7 4 3.4 3.4 - 3.9 3.3 - 3.6 13.3 14.6 11.6 10.6 18.6 15.5 35 Rated Current +-15% (mA) Resistive Operating extremes Operating extremes Damage limits Between contact and coil Between pole Damage limits Contact Voltage (V) Contact Voltage 24V 48V 60V 110V - 125V 220V - 240V 18V 12V 18V 24V 9V 12V 6V *Operation frequency 1800 operations per hour. Inductive

Shock Resistance Vibration Resistance Mechanical Life (without load) Operating Temperature Operating Humidity Weight Contact Configuration Contact material Degree of Protection Dielectric strength Number of Poles Contact Current (A) Current Contact AC/DC DC Contact Ratings Rated Voltage RV1H Relay Coil Ratings Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 758 RV8H Internal Connection(bottomview) *Available inblack,grayandblue. SV9Z-J20* SV9Z-PW10 SV9Z-SA2W RV1H-G Relay 3 1 1.2 71.4 A1 6.1 A2 5

16.5

0.9 3.5 15.0 3.78 0.5 0.5 12 Cut 115.9 120 96.7 35 (13+) 16.38 5.04 11 86.5 28 14 6 5.04 1 Note: Drawingsarenottoscale. 10.5 66.8 2

2.8 6

12.3 Dimensions (mm) Relays &Sockets www.IDEC.com RV8H-L ScrewTerminal Marking PlatePlacement RV8H-S SpringClampTerminal 74.2 5  9+ 0DUNLQJ3ODWH A2(-) Coil A2(-) Coil A1(+) Coil A1(+) Coil  88 35  ,QVHUW 11 (13+) COM 14 NO 11 (13+)COM 14 NO 12 NC 12 (NC)

 69.6  6.1 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RJ 759

EN61810-1 Directive EC Low Voltage Coil Voltage Code Coil Voltage (Standard Stock in bold) A24, A110, A120, A220, A240, D12, D24, D48, D100 A12, A24, A120, A240, D5, D12, D24, D48, D100 D12, D24, D48, D100 A24, A110, A120, A220, A240, D12, D24, D48, D100 D12, D24, D48, D100 A12, A24, A120, A240, D5, D12, D24, D100 D5, D12, D24, D48, D100 A24, A110, A120, A220, A240, D5, D6, D12, D24, D48, D100 RJ1S-C- A120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Part No. Coil Voltage Code Part No. Coil Voltage Part Number RJ1S-C- RJ1V-C- RJ2S-C- RJ1V-A- RJ2V-C- RJ2V-A- RJ22V-C- RJ2S-CD- RJ22S-C- RJ22S-CD- RJ1V-AH- RJ1S-CD- RJ1S-CL- RJ22V-A- RJ1S-CLD- RJ2S-CL- RJ2S-CLD- RJ22S-CL- RJ22S-CLD- RJ1V-CH- EN61810-1 VDE (REG.-Nr B312)

Ordering Information When ordering, specify the Part No. and coil voltage code: (example)

USA & Canada • Part Number Selection Part Relays & Sockets & Relays Model Standard Standard Standard Standard Standard Bifurcated contacts Standard High Capacity with Surge Suppresion Standard Bifurcated contacts (without LED indicator) Bifurcated contacts diode (without LED indicator) with Surge Suppresion Diode with LED Bifurcated contacts with LED & Surge Suppresion Diode with LED with LED & Surge Suppresion Diode Bifurated contacts (with LED indicator) Bifurcated contacts diode (with LED indicator) High Capacity CSA C22.2 No. 14 1608322 CSA File No. LR35144

Slim Power Relays Power Slim Series RJ

800-262-IDEC (4332)

Contact SPDT SPDT SPST-NO DPDT DPST-NO DPDT DPDT DPST-NO Terminal PCB Blade UL508 Compact and rugged power relays. Large switching capacity rugged power relays. Large Compact and only 12.7-mm wide. Compact housing rating Large contact @250V AC) 16A (UL general use rating RJ1 (1-pole): RJ2 (2-pole): 8A RJ2 (2-pole): unique light guide structure enables available on blade type. IDEC’s Non-polarized LED indicator from any direction. high visibility of coil status contact relay The smallest width for 2-pole/bifurcated mechanical life. Excellent electrical and (AC load) Electrical life: 200,000 operations operations (AC coil) Mechanical life: 30 million hexavalent chromium, PBB or PBDE. mercury, (EU directive 2002/95/EC). Contains no lead, cadmium, RoHS directive compliant Diode model: voltage: 1000V Diode reverse withstand EN compliant. UL recognized, CSA certified, • • • • • • • • UL File No. E55996 Style

Key features: RJ Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 760 RJ Accessories Sockets Coil Voltage Table Coil Rating Marking Plate Stop DIN RailEnd (1 meterlength) DIN Rail Aluminum Item Coil Voltage Code PCB Blade Models Models

RJ1V (Std) RJ2S (Std)/RJ22S RJ1S (Std) RJ1V (HC)RJ2V/RJ22V *Hold-down cliporspringmustberemovedtousewithRJPCBrelays. Relays Appearance 12V AC A12 Shown withoptionalmarkingplate. Standard DINRailMount 24V AC A24 SJ2S-05BW SJ1S-05BW — — 110V AC A110 Finger safesockets(ONLY) DIN rail All DINrailsockets Use with 120V AC A120 Finger-safe DINRailMount 220V AC A220 SJ2S-07LW SJ1S-07LW SQ1V-07B* SQ2V-07B* Relays &Sockets www.IDEC.com 240V AC SJ9Z-PWPN10 BNL5 BNDN1000 Part No. A240 5V DC D5 10 piecesperpack 9.1 mmwide. length is39”(1,000mm). (10.5mm) inheightand1.37(35mm)width(DINstandard).Standard Made ofdurableextrudedaluminum,theBNDN1000measures0.413 The BNDN1000isdesignedtoaccommodateDINmountsockets. Remarks PCB Mount SQ1V-63* SQ2V-63* SJ2S-61 SJ1S-61 6V DC D6 12V DC D12 Jumpers forSJSockets Replacement HoldDownSprings Poles SQ9Z-C63 SQ9Z-C SJ9Z-CM Part Number 10 2 8 5 24V DC D24 Part Number SJ9Z-JF10 SJ9Z-JF8 SJ9Z-JF5 SJ9Z-JF2 48V DC SQ1V-63, SQ2V-63 SQ1V-07B, SQ2V-07B SJ2S-05BW, SJ2S-07LW SJ1S-05BW, SJ1S-07LW, D48 Used WithSocket 100-110V DCVDC Quantity of 10. quantities purchase in Must D100 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RJ 761 RJ22V

DPDT: 17g, DPST-NO: 16g 17g, DPST-NO: DPDT: DPDT (bifurcated), DPDT (bifurcated), (bifurcated) DPST-NO Flux-tight structure AgNi (gold clad) 2 2-pole RJ22S 3000V AC, 1 minute 2 19g AC load: 100,000 operations minimum (operation frequency 1,800 per hour) DC load: 200,000 operations minimum (operation frequency 1,800 per hour) AC load: 10 million operations minimum (operating frequency 18,000 operations per hour) DC load: 20 million operations minimum (operating frequency 18,000 operations per hour) DPDT bifurcated contacts DPDT bifurcated , NC contact: 100 m/s 2 1000 m/s 50 mΩ maximum 5000V AC, 1 minute 1000V AC, 1 minute –40 to +70°C (no freezing) 5 to 85% RH (no condensation) 10 to 55 Hz, amplitude 0.75 mm 10 to 55 Hz, amplitude 0.75 mm 10 to 55 Hz, amplitude 0.75 RJ2 IP40

NO contact: 200 m/s 15ms maximum (with diode: 20 ms maximum) 15ms maximum (with diode: 10 ms maximum (with diode: 20 ms maximum) 10 ms maximum (with diode: DPDT Silver-nickel alloy Silver-nickel USA & Canada • — RJ1 Relays & Sockets & Relays 19g (blade type), 17g (PCB form C type), 16g (PCB form A type) AC load: 200,000 operations minimum (operation frequency 1800 operations per hour) DC load: 100,000 operations minimum (operation frequency 1800 operations per hour) AC coil: 30,000,000 operations minimum (operation frequency 18,000 operations per hour) DC coil: 50,000,000 operations minimum (operation frequency 18,000 operations per hour) 1-pole SPDT 800-262-IDEC (4332) 1 Model 3 Between contact and coil same pole Between contacts of the poles Between contacts of different Operating extremes Damage limits Operating extremes Damage limits 2 2 Measured using 5V DC, 1A voltage drop method. time. Measured at the rated voltage (at 20°C), excluding contact bounce 100% rated voltage. Note: Above values are initial values. 1. 2. 3. Dielectric Strength Vibration Resistance Shock Resistance Release Time Release Time Operating Humidity (approx.) Weight Electrical Life (rated load) Mechanical Life (no load) Operating Temperature Operating Temperature Operating Time Operating Time Number of Poles Contact Configuration Contact Material Degree of Protection Contact Resistance (initial value) Contact Resistance (initial Specifications

Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 762 RJ Contact Ratings Coil Ratings

Contact Ratings Coil Ratings

PCB Models Blade Models 3. 2. 1. DC AC The maximumallowablevoltageisthevaluewhichcanbeappliedtorelaycoils. Operating characteristicsareat20ºC. LED IndicatorisonlyavailableonBladeorBifurcatedrelays. 1 pole (bifurcated contacts) (bifurcated contacts) Bifurcated Bifurcated Models Models Models Models Models Rated Voltage Rated Voltage & PCB Blade Blade PCB Model 2poles 2 poles 2 poles 2 poles 1 pole Standard Capacity High Type Type 100-110V 100-110V 100-110V 240V 120V 120V 240V 12V 24V 48V 24V 12V 48V 24V 12V 48V 24V 12V 24V 5V 5V 6V Contact NO NO NO NO NO NO NO NC NC NC NC NC NC NC Voltage Voltage Code Code D100 A240 A120 D100 D100 A120 A240 Coil Coil D12 A24 D48 D24 A12 D48 D24 D12 D48 D24 D12 A24 D5 D5 D6 250VA AC 250VA AC Resistive Allowable ContactPower 2000V AC 2000V AC 4000V AC 4000V AC 2000V AC 2000V AC 3000V AC 3000V AC 3000V AC 3000V AC 30W DC 30W DC 120W 240W 240W 480W 180W 360W Load 50Hz Without LED Without LED 43.9 87.3 43.9 4.3 8.8 8.8 4.3 5.3 -5.8 5.3 -5.8 5.3-5.8 44.2 11.0 22.1 22.1 44.2 11.0 22.1 44.2 88.3 106 106 Rated Current(mA) Rated Current(mA) 11 ±15% (at20ºC) ±15% (at20ºC) 60Hz 37.5 75.0 37.5 3.7 7.5 7.5 3.7 Inductive Load 100VA AC 100VA AC 1 1 15W DC 15W DC 1000VA 1000VA 2000VA 2000VA 1000VA 1000VA 1875VA 1875VA 1875VA 1875VA 120W 120W 240W 180W 60W 90W 50Hz 47.5 91.1 47.5 4.3 8.7 8.7 4.3 With LED With LED 5.2 -5.7 5.2-5.7 48.0 10.7 25.7 25.7 48.0 10.7 110 – – – – – – 60Hz 41.1 78.8 41.1 3.7 7.4 7.4 3.7 Relays &Sockets www.IDEC.com 1 1 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC 250V AC Voltage 30V DC 30V DC 30V DC 30V DC 30V DC 30V DC 30V DC 30V DC (ohms)±10% (ohms)±10% Resistance Resistance (at 20ºC) (at 20ºC) 18,870 18,870 25,570 18,870 25,570 4,340 1,080 6,400 1,080 4,340 4,340 1,080 6,400 47.2 47.2 62.5 67.9 Coil Coil 271 243 271 271 243 Resistive Rated Load Load 16A 16A 16A 12A 12A 12A 12A 12A 1A 1A 4A 8A 8A 8A 8A 1A 1A 8A 8A 6A 70% max 80% max 70% max 70% max Voltage Voltage Pickup Pickup cosø=0.3 L/R=7ms Inductive Load 0.4A 0.5A 0.4A 0.5A 7.5A 7.5A 7.5A 7.5A Operating Characteristics Operating Characteristics 2A 4A 4A 4A 4A 8A 8A 8A 4A 4A 3A 6A Dropout Dropout 10% min 30% min 10% min 10% min Voltage Voltage Switching Allowable Current 16A 12A 16A 1A 4A 8A 8A 1A 4A 4A 6A 6A Allowable Voltage Allowable Voltage Maximum Maximum 2 2 160% 160% 170% 140% 170% 170% 160% Switching Allowable 125V DC 250V AC 125V DC 250V AC Voltage DC125V AC250V DC125V AC250V AC250V DC125V AC250V AC250V DC30V DC30V 3 3 Consumption Consumption 0.53 to0.64W 0.9VA (60Hz) 1.1VA (50Hz) 0.53-0.64W 0.9 to1.2VA Applicable Minimum Approx. Approx. Power Power 0.53W 100mA 100mA 100mA (60Hz) 100μA 100μA 1V DC 1V DC 10mA 10mA DC5V DC5V DC5V DC5V DC5V Load Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RJ 763 — — — — Torque 0.6 - 1.0N•m 0.6 - 1.0N•m 0.6 - 1.0N•m 0.6 - 1.0N•m 1.0N•m Maximum 1.0N•m Maximum (Maximum 1.2N•m) (Maximum 1.2N•m) (Maximum 1.2N•m) (Maximum 1.2N•m) – 1A NC — — — — Wire Size RJ22 – 1A NO Maximum up to 2 - #14 AWG Maximum up to 2 - #14 AWG Maximum up to 2 - #14 AWG Maximum up to 2 - #14 AWG Maximum up to 2 - #14 AWG Maximum up to 2 - #14 AWG 2A 4A NC RJ2 Inductive 4A 4A NO 250V, 8A 250V, 8A 250V, 250V, 8A 250V, 250V, 12A 250V, 12A 250V, 12A 300V, 10A 300V, 12A 250V, 12A 300V, 12A 300V, 3A NC 7.5A Electrical Rating RJ1 6A NO 7.5A – – USA & Canada 1A 1A NC NC • CSA RJ22 RJ22 Resistive – – 1A 1A NO NO Relays & Sockets & Relays – 2A 3A 4A 1A 8A NC NC NO RJ2 Terminal RJ2 RJ22 Resistive – 6A 8A 1A 8A NO NO NO RJ1 800-262-IDEC (4332) 2.5A AC-15, DC-13* UL 1A 4A 1A 4A NC NC NC 6A 12A M3 screw with captive wire clamp M3 screw with captive wire clamp, fingersafe M3 screw with captive wire clamp, fingersafe PCB mount M3 screw with captive wire clamp M3 screw with box clamp, fingersafe M3 screw with box clamp, fingersafe PCB mount PCB mount PCB mount RJ1 RJ2 VDE RJ22 1A 8A 1A 8A NO NO NO 12A 12A General Use Resistive – Socket SJ1S-61 SJ2S-61 8A 8A 6A 1A SQ1V-63 SQ2V-63 NC NC NO 6A RJ2 SQ1V-07B SQ2V-07B SJ1S-07LW SJ2S-07LW SJ2S-05BW SJ1S-05BW RJ1 RJ22 – 1A NO NO NO RJ1 12A 12A 12A 16A General Use *According to the utilization categories of IEC60947-5-1 Voltage Voltage Voltage 30V DC Finger-safe Finger-safe DIN Rail/Panel Mount PCB Mount 30V DC 250V AC 30V DC DIN Rail/ Panel Mount 250V AC 250V AC

Socket Specifications Agency Ratings Agency Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 764 RJ Operating Temperature andCoilTemperature Rise Maximum SwitchingCapacity(ResistiveLoad) Electrical LifeCurve(ResistiveLoad)

RJ2 (ACCoil,60Hz) RJ1 (ACCoil,60Hz) Load Current (A) RJ1 (× 10,000 operations) RJ1 1000 0.1 Temperature Rise (C) Temperature Rise (C) 100 10 12 10 100 110 120 130 1 1 10 20 30 40 50 60 70 80 90 100 110 120 130 1 0 10 20 30 40 50 60 70 80 90 0 DC Coil DC Resistive(NOContact AC Coil(60Hz) No LoadCurrent 10 10 Load Current(A)L Load Current12A¥1pole (NO Contact 30V DCResistiveLoad 0.1 Ambient Load No LoadCurrent 10 Ambient 20 AC Resistive(NOContact) 20 Load Current8A¥2poles V oltage (V) 30 T ) 30 emperature (C) ) T emperature (C) 1 40 100 40 250 50 50 12 (NO contact) Resistive Load 250V AC 60 60 70 70 RJ1 HighCapacity RJ1 HighCapacity (× 10,000 operations) 1000 Load Current (A) 100 10 RJ2 (ACCoil,50Hz) RJ1 (ACCoil,50Hz) 0.1 1 16 10

Temperature Rise (C) Temperature Rise (C) 1 11 100 110 120 130 100 110 120 130 10 20 30 40 50 60 70 80 90 10 20 30 40 50 60 70 80 90 DC Inductive(NOContact) DC Resistive(NCContact) 0 0 AC Coil(50Hz) AC Coil(50Hz) (NO Contact 30V DCResistiveLoad 0.1 Load Current12A¥1pole 10 10 oad Current(A Load V No LoadCurrent No LoadCurrent (NC Contact) DC Inductive Load Current8A¥2poles 0 Ambient Ambient 20 20 oltage (V Relays &Sockets www.IDEC.com ) AC Resistive (NO Contact) 1 DC Resistive 30 T 30 emperature (C) T 100 )L emperature (C) ) 40 40 250 AC Inductive 50 16 50 (NO contact) Resistive Load 250V AC 60 60 70 70 RJ2

Load Current (A) RJ2 0.1 10

(× 10,000 operations) 1000 1 8 100 1 10 1 1 RJ2 (DCCoil) RJ1 (DCCoil)

Temperature Rise (C) Temperature Rise (C) DC Resistive(NOContact 100 110 120 130 10 20 30 40 50 60 70 80 90 100 110 120 130 0 10 20 30 40 50 60 70 80 90 (NO Contact 30V DCResistiveLoad 0 DC Coil AC Resistive(NOContact) 10 DC Coil 0.1 Load oad Current(A) No LoadCurrent 10 No LoadCurrent 10 V oltage (V) Ambient ) Ambient 20 ) 20 Load Current12A¥1pole Load Current8A¥2poles 18 100 30 T T 30 emperature (C) emperature (C) 250 40 40 (NO contact) Resistive Load 250V AC 50 50 60 60 70 70 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RJ 765 5(24) 4(14) 4(14) 5(24) 4(14) 5(24) 3(11) 6(21) 70 70 3(11) 6(21) 3(11) 6(21) 60 60 70 2(12) 7(22) 2(12) 7(22) 50 50 60 40 40 50 8 1 30 30 (A2) (A1) DC Coil DC Coil 40 Coil voltage greater than 24V DC – + 1 8 1 8 20 (A1) (A2) 20 30 (A1) (A2) Coil voltage greater than 24V AC/DC DC Coil Load current 1A x 2 poles No load current RJ22V-A-* RJ22V-A-* Load current 1A x 2 poles No load current 10 Ambient Temperature (°C) 10 Ambient Temperature (°C) 20 Load current 1A x 2 poles No load current 10 5(24) 4(14) 0 Ambient Temperature (°C) 0 90 80 70 60 50 40 30 20 10 4(14) 5(24) 4(14) 5(24)

90 80 70 60 50 40 30 20 10 4(14) 5(24)

130 120 110 100 130 120 110 100 Temperature Rise (°C) Rise Temperature Temperature Rise (°C) Rise Temperature 6(21) 3(11) 0 RJ22 (DC Coil) RJ22

3(11) 6(21) 3(11) 6(21) 90 80 70 60 50 40 30 20 10

3(11) 6(21) 130 120 110 100 Temperature Rise (°C) Rise Temperature 7(22) 2(12) 2(12) 7(22) 2(12) 7(22) 2(12) 7(22) 70 70 – + Coil voltage 24V DC and below – 60 + 1 8 60 1 8 1 8 70 1 8 (A1) (A2) (A1) (A2) (A2) (A1) Coil voltage 24V AC/DC and below (A1) (A2) 50 50 60 40 40 50 RJ2-CL/RJ22-CL-* With LED Indicator RJ2-CD-/ RJ22-CD-* With Diode and Diode RJ2-CLD/ RJ22-CLD-* With LED Indicator RJ2-C/RJ22-C-* Standard 30 30 40 AC Coil (50 Hz) 20 AC Coil (50 Hz) 20 30 Load current 1A x 2 poles No load current Load current 1A x 2 poles No load current USA & Canada Ambient Temperature (°C) 10 • 3(14) Ambient Temperature (°C) 10 AC Coil (50 Hz) 20 3(14) Load current 1A x 2 poles No load current Ambient Temperature (°C) 10 0 4(11) 0 90 80 70 60 50 40 30 20 10 4(11)

90 80 70 60 50 40 30 20 10

130 120 110 100

130 120 110 100 Temperature Rise (°C) Rise Temperature Temperature Rise (°C) Rise Temperature 2(12) Relays & Sockets & Relays 0 2(12) 90 80 70 60 50 40 30 20 10

130 120 110 100 RJ22 (AC Coil, 50 Hz) (AC Coil, RJ22 (°C) Rise Temperature – + 70 70 1 5 1 5 800-262-IDEC (4332) Coil voltage greater than 24V DC (A1) (A2) (A1) (A2) Coil voltage greater than 24V AC/DC 60 60 70

50 50 60 3(14) 40 40 3(14) 3(14) 50 3(14) 30 30 4(11) 40 4(11) 4(11) AC Coil (60 Hz) 4(11) AC Coil (60 Hz) 20 20 30 2(12) 2(12) 2(12) Load current 1A x 2 poles No load current Load current 1A x 2 poles No load current 10 AC Coil (60 Hz) 2(12) Ambient Temperature (°C) 10 Ambient Temperature (°C) 20 Load current 1A x 2 poles No load current 10 0 Ambient Temperature (°C) 0 90 80 70 60 50 40 30 20 10

90 80 70 60 50 40 30 20 10

– 130 120 110 100 +

– + 130 120 110 100 (°C) Rise Temperature Temperature Rise (°C) Rise Temperature 5 1 5 1 5 1 5 1 Coil voltage 24V DC and below (A2) (A1) 0 (A2) (A1)

(A2) (A1) 90 80 70 60 50 40 30 20 10 Coil voltage 24V AC/DC and below (A2) (A1)

130 120 110 100 The above temperature rise curves show characteristics when 100% the rated coil voltage is applied. show characteristics when 100% the rated coil voltage is The above temperature rise curves temperatures. allowable temperature rise for the coil at different ambient The slanted dashed line indicates Temperature Rise (°C) Rise Temperature RJ1-CLD-* With LED Indicator and Diode RJ1-CD-* With Diode RJ1-CL-* With LED Indicator Internal Connection (View from Bottom) RJ1-C-* Standard RJ22 (AC Coil, 60 Hz) (AC Coil, RJ22 Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 766 25.5 max. (25.3) 25.5 max. (25.3) RJ 4.0 0.3 PCB Relay(mm) Blade Relay(mm) RJ22V-C-* RJ1V-CH-*/RJ2V-C-* RJ1V-C-* RJ1S 4.0 0.3 0.3 25.5 max. 0.3 ø1.8 ¥ 3 hole 25.5 max. (25.3) 25.5 max. (25.3) (25.3) 4.0 4.0 0.3 0.3 0.3 0.3 29 max.(28.8)

4.0 0.3 29 max.(28.8)

0.4 27.0 0.5 0.5 29 max.(28.8) 29 max.(28.8)

0.5

0.5

5 0.5 1 0.5 0.5 0.6 0.5 29 max. 31.1 (28.8) 4.8 28.8

0.5

0.5 0.6 2 13 max. 13 max. 0.5

(12.7) 0.5

(12.7) 0.5 4

13 max. 13 max. (12.7) 3 (12.7) 0.6 1.0 1.0 13 max.

(12.7) 12.7

1.0 5.0 28.0 1.0 (1.9) (1.9)

1.1 (2.6) (2.6)

8-ø1.3 holes 8-ø1.3 5-ø1.3 holes 5-ø1.3 (1.9)

(1.9) (2.6) (2.6)

8-ø1.3 holes 8-ø1.3 5-ø1.3 holes 5-ø1.3 4.8 0.5 20.0 20.0 5.0 3.5 20.0 20.0 5.0 3.5 Dimensions (mm) 3.5 5.0 Relays &Sockets www.IDEC.com

7.5 7.5 3.5 5.0

7.5 7.5 ø1.2 ¥ 3 hole

25.5 max. (25.3) RJ2S/RJ22S 25.5 max. (25.3) 4.0 0.3 0.5 0.3 4.0 0.3 0.3 RJ22V-A-* RJ1V-AH-*/RJ2V-A-* RJ1V-A-*

25.5 max.

25.5 max. (25.3) 25.5 max. (25.3)

1 (25.3) 4.0 8 29 max.(28.8) 0.3

4.0 0.3 0.3 0.3 4.0 0.3 29 max.(28.8) 0.4 2.6 31.1

0.5 29 max.(28.8)

29 max.(28.8) 28.8 0.5

7 2

6 3 0.5 0.5 0.5 29 max.

(28.8)

0.5

4 0.5 5 0.6 13 max. (12.7) 13 max. (12.7) 0.5 0.5 6.0 27.0 All dimensionsinmm. 12.7 13 max. 13 max. (12.7) 1.0 (12.7) 0.6 1.0 13 max. (12.7) 1.0 1.0 (1.9)

(2.6) (1.9)

(2.6) 1.1 2.6 6-ø1.3 holes 6-ø1.3 (1.9)

(1.9) (2.6) (2.6) 4-ø1.3 holes 4-ø1.3 20.0

20.0

6-ø1.3 holes 6-ø1.3 4-ø1.3 holes 4-ø1.3 20.0 20.0 5.0 3.5 7.5 7.5 3.5 5.0 7.5 7.5 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RJ 767

4

55.7

55.7 ø3

6

49.5 2 29.7

22 12

6 3 35.5 (21) (11)

21

11 2 21.5 7 (22) (12)

ø5.6 M3 Terminal Screws 24 14 5 42 (24) (14) (21) (11) 3 6 M3 Terminal Screws 5 4 VIEW) (14) (24) 71 OP (T 71 (TOP VIEW) (TOP VIEW) (A2) (A1) A1 A2 (22) (12) 8 1 7 2 8 1

(A2) (A1)

15.5 29.7

4.3 15.5 4.3 SQ2V-07B SJ2S-05BW SJ2S-07LW USA & Canada • Dimensions con’tDimensions (mm)

Relays & Sockets & Relays 4

55.7

55.7 ø3

49.5 6

2 29.7

12 35.5

11 (12)

(11) 2 21.5 2

ø5.6 800-262-IDEC (4332) M3 Terminal Screws 14 34 (14) 4 (14) M3 Teminal Screws VIEW) 3 (11) OP (T 71 (TOP VIEW) 71 (TOP VIEW) (A2) (A1) A1 A2 (12) 5 1 2 (A2)

1 5

(A1)

15.5 29.7

4.3 15.5 4.3 SQ1V-07B SJ1S-07LW SJ1S-05BW Finger-safe DIN Rail Mount Sockets Finger-safe Standard DIN Rail Mount Sockets Standard Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 768 RJ PC MountSockets SQ1V-63 SJ1S-61 4.0 36.5 14.0 32.5

1.0 (4.7) 7.0 ±0.1 4.0 ±0.1 4.5 15.0 ±0.1 ±0.1

6.0 5-ø1.6 holes 5-ø1.6 ±0.1 4.0 ±0.1 Dimensions con’t (mm) Dimensions con’t T erminal 5 (Bottom 1 Arrangement 2 View) 4 Relays &Sockets www.IDEC.com 3 SQ2V-63 SJ2S-61

4.0 36.5 14.0 32.5

1.0 (4.3) 7.5 ±0.1 20.0 5.0 ±0.1 ±0.1

5.0 8-ø1.3 holes 8-ø1.3 ±0.1 T erminal (Bottom 8 1 Arrangement 7 23 View) 6 5 4 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RQ 769 RQ1V-CM A115 RQ1V-CM Part No. Coil Voltage Code Part No. Coil Voltage When ordering, specify the Part No. and coil voltage code: (example) Ordering Information D110 110V DC Coil Voltage Code Coil Voltage A24, A115, A230, D12, D24 A24, A115, A230, D12, D24, D110 A24, A115, A230, D12, D24, D110 D24 24V DC USA & Canada 0 0 0 • R500562600001 D12 12V DC PCB Relays PCB RQ Series Part Number Selection Part RQ1V-CH- RQ2V-CN- Part Number RQ1V-CM- Pin Terminal Relays & Sockets & Relays A230 220-240V AC 800-262-IDEC (4332) Model A115 Basic Basic HIgh Capacity (HC) 110-120V AC UL Recognized File No. E59804 A24 24V AC 29 x 12.7 x 15 mm 8A (DPDT) and 12A (SPDT) Low profile: Contact rating: 16A (SPDT) contact rating High capacity model with Operational life: load 100K cycles at full resistive 10 million cycles, no load available with DIN rail socket LED/Diode Plug-in modules

• • • • • Coil Rating SPDT 16A DPDT 8A Coil Voltage Code Coil Voltage Contact SPDT 12A

Coil Voltage Table Coil Voltage Key features: IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small, Size equals value. relays in a compact package. are low-profile, PCB IDEC RQ relays 16A model is also a larger power needs, long operational life. For high contact ratings and yet maintain available. Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 770 RQ Specifications Accessories Sockets RQ1 Weight (Approx.) Dimensions (HxWDmm) Operating Humidity Operating Temperature Electrical Life@FullRatedLoad Mechanical Life Stop DIN RailEnd RQ1 HC RQ2 Dielectric Strength Release Time Operating Time Contact Resistance Contact Material Contact Rating Contact Configuration No. ofpoles (1 meterlength) DIN Rail Aluminum Item Vibration Resistance Shock Resistance Relays 2. 1. † *Comes withholddownspring Comes withretainingclipandmarkingplate. SQ1V-07B SQ2V-07B Finger-safe DIN Rail Mount Appearance Model (Contact) † † Between contacts Between contact&coil Operating extremes Damage limits Operating extremes Damage limits SQ2V-63* SQ1V-63* PCB Mount DIN rail All DINrailsockets Use with SPDT RQ1 12A 1 10-55 Hz,amplitude1.5mm 10-55 Hz,amplitude1.5mm Replacement Parts&Accessories SQ9Z-C SQ9Z-C63 SQ9Z-J8 Part Number 10,000,000 operations 1,000m/s 1,000VAC, 1minute 5,000VAC, 1minute 100,000 operations 100m/s Silver-Nickel alloy 45 to85%RH 29 x12.715 100mΩ max -40 to85ºC RQ1 HC SPDT 12 ms 16A 8 ms 15g 2 1 2 min(10G) min(100G) Relays &Sockets www.IDEC.com Replacement retainingclip for SQPCBsockets Replacement hold-downspring 8 ptjumperforDINsocket BNL5 BNDN1000 Part No. DPDT RQ2 8A 2 Description 9.1 mmwide. (35mm) inwidth(DINstandard).Standardlengthis39”(1,000mm). aluminum, theBNDN1000measures0.413(10.5mm)inheightand1.37 signed toaccommodateDINmountsockets.Madeofdurableextruded IDEC offersalow-profileDINrail(BNDN1000).TheBNDN1000isde Remarks SQ9Z-LD SQ9Z-LR SQ9Z-P Part Number Diode pluginmodulesforDINsocket DIN socket RC plug-inmodule(110-230VAC)for Replacement markingplate Description - Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RQ 771 0 — — Torque 130% 130% 02 1.0N•m Maximum 1.0N•m Maximum 51 Max Allowable Voltage Max Allowable ) RQ1 RQ2 RQ1-HC 12 .5 Load Current (A — — 20 5% Min 0. Wire Size 30% Min 1 Dropout Voltage 0.

50 40 30 20 10

300 200 100 Maximum up to 2 - #14 AWG Maximum up to 2 - #14 AWG

) V ( d a o l f o e g a t l o V RQ1, RQ1 High Capacity & RQ2 NO C iew NC 16 RQ1 HC 80% Max 80% Max Bottom V 14 Pickup Voltage 300V, 8A 300V, 300V, 12A 300V, 12A 300V, 300V, 12A 300V, 12 Electrical Rating 0

81 60HZ 0.61W 0.73W 0.63W 6 USA & Canada Load Current (A) • iew RQ1V-CH Dimensions 0.40W NO NO 24 om V 50HZ C C Power Consumption 0.71W 0.88W 0.79W 0 iew Bott 7 5 6 4

Relays & Sockets & Relays

10 10 10 10

NC NC o i t a r e p O ns RQ2 RQ2 Terminal Bottom V Coil 350Ω 360Ω 1,440Ω 8,100Ω Q1-HC 26,530Ω 32,500Ω 800-262-IDEC (4332) Resistance 16 14 M3 screw with box clamp PCB mount M3 screw with box clamp PCB mount RQ1R RQ2V-CN Dimensions 12 60HZ 6.3mA 0 2.72mA 25.35mA NO iew 81 4.1mA 16.7mA 33.3mA Relays C SQ1V-63 SQ2V-63 iew SQ2V-07B SQ1V-07B om V 6 NC Nominal Current 50HZ 7.65mA 3.42mA Bott 29.75mA RQ1 4 Load Current (A) Bottom V 2 24V 24V 12V 110V 115V 230V 0 5 7 4 6

10 10 10 10

ns o i t a r e p O

Rated Voltage

RQ1 & RQ1 High Capacity AC DC PCB Mount Socket DIN Rail Sockets Internal Connection (View from Bottom) Maximum Switching Capacity Switching Maximum Curves Life Electrical Socket Specifications Coil Ratings RQ1V-CM Dimensions iew Bottom V Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 772 RQ SQ SocketDomensions SQ1V-63 PCBPinLayout SQ1V-07B RQ1 A2 A1 (T OP VIEW) 14 11 12 SQ1V-63 Dimensions (mm) Relays &Sockets www.IDEC.com SQ2V-07B SQ2V-07B RQ2/RQ1 HC SQ2V-63 PCBPinLayout SQ2V-63 A2 A1 (T OP VIEW) 14 24 11 21 12 22 SQ2V-63

Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RH 773 Coil Voltage Code Coil Voltage RH3B-U AC120V (Standard Stock in bold) DC6V, DC12V, DC24V, DC48V, DC110V DC48V, DC24V, DC12V, DC6V, , DC48V, DC110V DC12V, DC24V, DC48V, DC6V, AC24V, AC110-120V, AC12V, AC6V, AC220-240V DC100-110V DC12V, DC24V, DC48V, DC6V, DC100-110V DC12V, DC24V, DC48V, DC6V, AC120V, AC24V, AC110V, AC12V, AC6V, DC12V, DC24V, AC240V DC6V, AC220V, DC110V DC48V, AC120V, AC24V, AC110V, AC12V, AC6V, DC12V, DC24V, DC48V, AC240V DC6V, AC220V, DC110V , AC110V, AC120V, AC24V, AC110V, AC12V, AC6V, DC12V, DC24V, AC240V DC6V, AC220V, DC110V DC48V, , DC48V, DC110V DC12V, DC24V, DC48V, DC110V DC48V, DC24V, DC12V, DC6V, Part No. Coil Voltage Code Part No. Coil Voltage 0 0 0 0 0 0 0 0 0 0 0 nal Ordering Information When ordering, specify the Part No. and coil voltage code: (example) - PCB Termi — RH4V2-UD — — RH1V2-UD — RH2V2-U RH2V2-UL — — — RH2V2-UD RH2V2-ULD RH3V2-U RH3V2-UL — — — — — RH4V2-U RH4V2-UL — — RH1V2-U — — — 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Part Number 0 0 0 0 Blade Terminal RH1B-U RH4B-U RH4B-UC RH2B-U RH2B-UC RH3B-U RH3B-UC RH4B-ULD RH1B-ULD RH2B-UL RH2B-ULD RH3B-UL RH4B-UL RH1B-UL RH4B-UD RH1B-UD RH2B-ULC RH2B-UT RH2B-UD RH3B-ULC RH3B-UT RH3B-UD RH3B-ULD RH4B-ULC RH4B-UT RH1B-UC RH1B-ULC RH1B-UT USA & Canada • Part Number Selection Number Part Relays & Sockets & Relays Compact Power Relays Power Compact RH Series Model 800-262-IDEC (4332) Standard Standard With Check Button With Check Button Standard With Check Button Standard With Indicator and Diode (DC coil only) With Indicator and Diode (DC coil only) With Indicator With Indicator and Diode (DC coil only) With Indicator With Indicator With Indicator With Diode (DC coil only) With Diode (DC coil only) With Indicator and Check Button Bracket Mounting Top With Diode (DC coil only) With Indicator and Check Button Bracket Mounting Top With Diode (DC coil only) With Indicator and Diode (DC coil only) With Indicator and Check Button Bracket Mounting Top With Check Button With Indicator and Check Button Bracket Mounting Top PCB terminal relays are designed to mount directly to a circuit board without any socket. SPDT through 4PDT, 10A contacts 4PDT, SPDT through type relays Compact power capacity relays with a large Miniature power 10A contact capacity Compact size saves space • • • • • Contact SPDT 3PDT Key features DPDT 4PDT

RH Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 774 RH DC CoilRatings AC CoilRatings Hold DownSprings&Clips Sockets (forBladeTerminal Models) 6 110 100-110 48 24 12 Appearance RH4B RH3B RH2B Relays RH1B 6 24 12 110 110-120 120 240 220-240 220 Voltage Voltage (V) (V) Rated Current(mA)±15%at20°C SPDT SPDT 128 170 9.6 4.9 4.7 8.6 — — — 18 32 64 42 86 8 SH4B-05 SH3B-05 SH2B-05 Standard DINRailMount SH1B-05 8.2-9.0 4.7-5.4 DPDT DPDT 18.5 36.9 60.5 10.8 9.4- 150 240 121 — — — — — 75 AC 50Hz Item Leaf Spring(toplatch) Leaf Spring(sidelatch) Pullover WireSpring Rated Current(mA)±15%at20°C 3PDT 3PDT 12.8 18.1 16.4 240 120 330 165 8.2 8.8 — — — 30 60 81 4PDT 4PDT 21.6 10.7 19.5 250 125 387 196 9.8 1 — — — 31 62 15 98

SH4B-05C SH3B-05C SH2B-05C SH1B-O5C Finger-safe DINRailMount 13,800 SPDT SPDT 2,660 750 188 150 8.4 4.3 4.1 7.5 — — — 47 37 75 Coil Resistance(Ω) 8.0-9.2 4.0-4.6 12,250 DPDT DPDT 2,600 ±10% at20°C 650 160 200 100 — — — — — 40 50 AC 60Hz RH4B RH3B RH2B Relay RH1B, RH2B,RH3B,RH4B RH1B, RH2B,RH3B,RH4B RH1B 3PDT 3PDT 8,600 1,600 15.5 14.2 400 100 280 140 7.1 7.7 — — — 25 70 1 Relays &Sockets www.IDEC.com 4PDT 4PDT 7,340 1,550 18.2 16.5 388 330 165 8.3 9.1 — — SH4B-51 SH3B-51 SH2B-51 SH1B-51 Through PanelMount 24 96 83 SPDT 18.2 16.5 330 165 Max. Continuous 8.3 9.1 — — 83 Applied Voltage SH4B-02F1 SH3B-05F1 SY4S-02F1 Mount Socket For DIN SFA-101 SFA-202 SY2S-02F1 Coil Resistance(Ω) 110% 18,820 DPDT ±10% at20°C 39.3 153 9.4 — — — — — (against ratedvaluesat20ºC) 3 3 Operation Characteristics 2 2 2 2 12,100 10,800 10,800 3PDT 2,200 25.3 103 6.4 — — SH4B-62 SH3B-62 SH2B-62 SH1B-62 PCB Mount SFA-302 SY4S-51F1 SFA-301 PCB MountSocket For ThroughPanel& maximum Voltage Pickup 4PDT 1,800 9,120 7,360 7,360 21.2 84.5 80% 5.4 — — 3 3 Max. Continuous Applied Voltage 110% minimum Dropout Voltage (against ratedvaluesat20ºC) 10% Operation Characteristics

3. 2. Two requiredperrelay. part numberisY778-011. Replacement horseshoeclip mounting inDINmountsocket. Must usehorseshoeclipwhen maximum Voltage Pickup 1. 80% Y778-011. clip partnumberis ment horseshoe wire spring.Replace- plan toinsertpullover not useunlessyou horseshoe clips.Do comes withtwo DIN Railmountsocket

ages areinBOLD. Standard coilvolt- minimum Dropout Voltage 30% Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RH 775 — — — — RH4 — 1/3 HP 1/6 HP power Rating Horse- RH1, 2, 3 — — — — — Torque RH3 1/3 HP 1/6 HP 5A — RH4 7.5A 5.5 - 9 in•lbs 9 - 11.5 in•lbs 9 - 11.5 in•lbs 5.5 - 9 in•lbs 9 - 11.5 in•lbs 9 - 11.5 in•lbs — — Horsepower Rating Horsepower RH1 RH2 1/3 HP 1/6 HP 7A — — RH3 5A — — RH4 7.5A 7A RH2 7.5A 7.5A General Use — — — — — RH3 6.5A 7.5A 7A 7A RH1 7.5A Wire Size General Use 7A — — 7A RH1 RH2 10A 10A RH4 7.5A Maximum up to 2–#12AWG Maximum up to 2–#12AWG Maximum up to 2–#12AWG Maximum up to 2–#12AWG — 10A 10A RH4 7.5A — 10A 10A RH3 Resistive — 10A 10A RH3 7.5A 10A 10A 10A RH2 Resistive Remarks The BNDN1000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard length is 39” (1,000mm). 9.1 mm wide. For use on DIN rail mount socket when using pullover wire hold down spring. 2 pieces included with each socket. — — 10A 10A 10A RH1 10A 10A RH1 RH2 Electrical Rating 250V, 10A 250V, 10A 300V, 10A 250V, 10A 300V, 10A 300V, 10A 250V, 10A 300V, 30V DC Voltage 240V AC 120V AC Voltage 240V AC 120V AC 28V DC 30V DC CSA Ratings UL Ratings Part No. BNDN1000 BNL5 Y778-011 7A 7A 5A Ind. 4.5A 7.5A 7.5A Load USA & Canada • 10A RH4 7.5A 7A 10A 10A 10A 10A Res. 7.5A Load Rated Load Relays & Sockets & Relays (V) Terminal 10A RH3 7.5A 30 DC 30 DC 110 AC 220 AC 110 AC 220 AC Voltage Voltage Use with DIN mount sockets and hold down springs. All DIN rail sockets DIN rail 800-262-IDEC (4332) Load 210W 225W 990VA 1100VA Inductive 10A 10A RH2 (Coil) M3 screws (contact) M3.5 screws with captive wire clamp PCB mount M3.5 screws with captive wire clamp (coil) M3 screws (contact) M3.5 screws with captive wire clamp, fingersafe M3.5 screws with captive wire clamp, fingersafe Solder PCB mount Load 300W 300W 1540VA 1650VA Resistive Maximum Contact Capacity Maximum Contact Allowable Contact Power Allowable Contact 10A 10A RH1 SH1B-05 SH2B-62 SH3B-62 SH4B-62 SH2B-05 SH3B-05 SH4B-05 SH1B-51 SH2B-51 SH3B-51 SH4B-51 SH1B-62 Sockets SH1B-05C SH2B-05C SH3B-05C SH4B-05C Appearance 10A 10A Current Continuous AC: cos ø = 1.0, DC: L/R = 0 ms Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms Note: Inductive load for the rated 30V DC Voltage 240V AC 3PDT 4PDT SPDT DPDT Model Aluminum DIN Rail (1 meter length) Item DIN Rail Mount Sockets Finger-safe Finger-safe DIN Rail Mount Through Panel Mount Socket PCB Mount Socket DIN Rail End Stop Replacement Hold-Down Spring Anchor Contact Ratings Contact Accessories Socket Specifications

TÜV Ratings

Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 776 RH

Specifications (approx.) Power Consumption Release Time Weight (approx.) Operating Humidity Temperature Operating Electrical Life Mechanical Life Shock Resistance Vibration Resistance Operating Frequency Dielectric Strength Insulation Resistance Operating Time Minimum ApplicableLoad Contact Resistance Contact Material 4. 3. 2. 1. Note: Abovevaluesareinitialvalues. temperature rangeofrelayswithindicatorordiodeis–25to+40°C. For useunderdifferenttemperatureconditions,refertoContinuousLoadCurrentvs.Operating Temperature Curve.Theoperating Relays withindicatorordiode:1000VAC,1minute Release timeofrelayswithdiode:40msmaximum Measured attheratedvoltage(at20°C),excludingcontactbouncing Measured using5VDC,1Avoltagedropmethod 4 2 2 3 1 4PDT 3PDT DPDT SPDT 4PDT 3PDT DPDT SPDT 4PDT 3PDT DPDT SPDT 4PDT 3PDT DPDT SPDT SPDT 4PDT 3PDT SPDT DPDT 4PDT 3PDT DPDT Operating extremes: 100m/s AC: 2.5VA (50Hz),2VA (60Hz) AC: 2VA (50Hz),1.7VA (60Hz) AC: 1.4VA (50Hz),1.2VA (60Hz) AC: 1.1VA (50Hz),1VA (60Hz) 25ms maximum 20ms maximum 25ms maximum 20ms maximum SPDT: 24g,DPDT: 37g,3PDT: 50g,4PDT: 74g 45 to85%RH(nocondensation) –25 to+70°C(nofreezing) 50,000,000 operationsminimum Damage limits: Operating extremes: Damage limits: Mechanical: Electrical: Between contactsofthesamepole: Between contactandcoil: Between liveanddeadparts: 100MΩ minimum(500VDCmegger) 200,000 operationsminimum(120VAC,10A) 500,000 operationsminimum(120VAC,10A) Between contactsofthesamepole: Between contactsofdifferentpoles: Between contactandcoil: Between liveanddeadparts: 24V DC,30mA;5V100mA(referencevalue) 50mΩ maximum Silver cadmiumoxide 200m/s 1,000m/s 10 to55Hz,amplitude0.5mm 10 to55Hz,amplitude0.5mm 18,000 operations/hourmaximum 1,800 operations/hourmaximum

2 2 (10G-3PDT, 4PDT) (20G-SPDT, DPDT) 2 (100G) DC: 1.5W DC: 1.5W DC: 0.9W DC: 0.8W 1,000V AC,1minute 2,000V AC,1minute 2,000V AC,1minute 1,000V AC,1minute 2,000V AC,1minute 2,000V AC,1minute 2,000V AC,1minute Relays &Sockets www.IDEC.com Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RH 777 10 10 10 300 200 100 DC resistive AC inductive 50 AC resistive 30V DC inductive 579 579 579 30V DC resistive Load Current (A) Load Current (A) Load Current (A) DC inductive Load Voltage (V) 10 30V DC resistive 30V DC inductive 30V DC resistive 2468 2468 2468 100V DC resistive 100V DC resistive 30V DC inductive 13 13 13 100V DC inductive 100V DC inductive 100V DC inductive 100V DC resistive

50 20 10 50 20 10 50 20 10

500 100 500 100 500 100

Life (¥ 10,000 operations) 10,000 (¥ Life 1000 1000 1000 Life (¥ 10,000 operations) 10,000 (¥ Life Life (¥ 10,000 operations) 10,000 (¥ Life 15

0.1 5.0 1.0 0.5

10.0 (RH2/RH3/RH4) (A) Current Load (RH1) (RH2) (RH3/RH4) DC Load USA & Canada • 10 10 10 300 AC resistive AC inductive 200 AC resistive AC resistive AC inductive Relays & Sockets & Relays 240V 120V Characteristics (Reference Data) (Reference Characteristics 240V 240V 120V DC resistive 100 ) ) AC inductive ) 50 AC resistive 800-262-IDEC (4332) 579 579 AC inductive Load Current (A Load Current (A DC inductive 468 Load Voltage (V) 120V AC resistive Load Current (A 10 3579 120V AC resistive AC resistive AC inductive 2 2468 120V 120V 240V 2468 AC inductive AC inductive 1 13 240V 13 240V

50 20 10 50 20 10

10,000 operations) 10,000 ( 100 Life 500 100 500 10,000 operations) 10,000 ( Life

×

× 50 20 10 15

1000 1000 100 500 10,000 operations) 10,000 ( Life

1000 × 0.1 1.0 0.5 5.0

10.0 (RH1) (A) Current Load (RH1) (RH2) (RH3/RH4) Maximum Switching Capacity Electrical Life Curves Electrical AC Load Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 778 RH

With Diode(-Dtype) With Indicator(-Ltype) Basic Type Internal Connection(ViewfromBottom) Continuous LoadCurrentvs.OperatingTemperature Curve(BasicType, WithCheckButton,andTop BracketMountingType) and over AC/DC 100V AC/DC 100V Below (RH1) 13 ( –) SPDT SPDT 9 5 1 14 ( +) ° Operating Temperature ( C) 100 10 20 30 40 50 60 70 80 90 0 ( –) 13 ( –) 13 SPDT 1 5 1 9 9 5 1 2 Note: The ratedvoltageis ( +) 14 ( +) 14 appliedtothecoil. 3 Load Current(A) 4 5 9 5 1 13 AC Coil 6 ( –) DPDT DPDT 7 8 DC Coil 9 ( +) 9 5 1 13 9 5 1 10 14 13 12 8 4 ( –) ( –) 3PDT 10 10 6 2 6 2 ( +) ( +) 14 14 12 12 8 4 13 8 4 5 1 9 ( –) (RH2) 3PDT 3PDT 10 6 2

Operating Temperature (°C) 100 10 20 30 40 50 60 70 80 90 13 ( +) 0 13 5 1 9 9 5 1 12 8 4 ( –) 14 Relays &Sockets www.IDEC.com ( –) 1 2 10 Note: The ratedvoltageis 10 6 2 6 2 Load Current(A) appliedtothecoil. 3 4PDT 4 5 AC Coil 11 11 7 3 7 3 6 DC Coil 13 7 13 9 5 1 ( +) ( +) 9 5 1 ( –) ( –) 12 8 12 8 4 14 8 4 14 9 10 10 6 2 10 6 2 4PDT 4PDT over DC and 24V AC/ DC 24V AC/ Below 11 7 3 11 7 3 ( +) ( +) 12 8 4 14 12 8 4 14 (RH3/RH4) 13 9 5 1 5 1 9 ( –) 13 ( –) DPDT • coil only. release timeisslightlylonger. Available forDC generated whenthecoilisde-energized.The Contains adiodetoabsorbthebackemf check button. Contacts canbeoperatedbypressingthe With CheckButton Forward current:1A Reverse withstandvoltage:1,000V Diode Characteristics

Operating Temperature (°C) 100 ( +) 10 20 30 40 50 60 70 80 90 0 ( +) 14 12 12 8 4 8 4 14 1 2 Note: The ratedvoltageis AC/DC Coil appliedtothecoil. 3 Load Current(A) Pushbutton Front • • • the indicatorgoeson. When therelayisenergized, 4 is green LED colorofDPDTmodel indicator. above 100Vuseneonlamp use LEDindicator, coils Relay coilsbelow100V tion diode(exceptDPDT). DC donotcontainaprotec- Relay coilslessthan100V 5 6 7 8 9 10

Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers

RH

779 27.5

4 8 14 12 27.5 max. 1 5 9 ) 13

41.6 8 4

11 (

14 5.9

10 4.7 7.25

6 2

10

31 0.5 4.7 6.4 13 1 5 9 SH3B-51: 39.6 Dimensions in the ( ) include a hold-down spring.

ø2.6 hole

4.7 0.5 max., 6.4 ) 2 35.6 max. Contains an LED indicator and Contains an LED indicator and and has the a surge absorber, same height as the basic type. LED color of DPDT model is green. 63.5 ( 14 ø2.6 hole 14 ( + ) 4 8 4 8 12 12 ( + ) 35.6 max. 21.5

SH3B-05: 61.5 Total length from panel surface including relay socket length from panel surface including Total 38

3.5 DPDT 43.2 ( – ) 1 5 9 1 5 9

13

RH2B-UT RH3B-U/RH3B-UL/RH3B-UD/RH3B-ULD ( – ) 13 28

14

4 8 12

27.5 3 7 11 27.5 28 41.5 3.5 6 2 10 14 1 5 9 max. Below 24V AC/ DC 24V AC/ DC and over 13 ) 5 9 1

13

14 4 8 12 5.9

41.6

(

21 4.7 6.6 4.7 5.9

1 5 9

13

7.25 4.7 0.5

6.4 5.4 10 10 10 0.5

6.4 4.7 Dimensions in the ( ) include a hold-down spring. SH2B-51: 39.6 ø2.6 hole

ø2.6 hole

0.5 4.7 max., 2 42 max. 35.6 max. 6.4 ) 35.6 max. 4PDT 63.5 ( USA & Canada 2 • ø2.6 hole Dimensions (mm)

35.6 max. SH2B-05: 61.5 38 Total length from panel surface including relay socket length from panel surface including Total

3.5 43.2 14.5

Relays & Sockets & Relays

38

RH1B-UT 44 RH2B-U/RH2B-UL/RH2B-UD/RH2B-ULD RH4B-UT 28

14

27.5 4 8 12 27.5 800-262-IDEC (4332) 3PDT 2 6 10 max. max. ) ) 4 8 1 5 9 12 13 14 14

41.6 5 41.6 1 9

( (

3 7 5.9 14 11 13

4.7 7.25 10 41 10

6 2 10 0.5 4.7 6.4 13 5 9 1 Dimensions in the ( ) include a hold-down spring.

SH1B-51: 39.6

SH4B-51: 39.6 Dimensions in the ( ) include a hold-down spring. 4.7

0.5

( + ) ø2.6 hole

0.5 14 4.7 ( + ) 14 max., 2 max., 6.4 6.4 ) 5.4 ) 35.6 max. 9 1 5 1 5 9 SPDT 63.5 63.5 ( – ) ( ( 13 ( – ) 13 3.5 ø2.6 hole ø2.6 hole 21.5 31.5 35.6 max. 35.6 max.

SH1B-05: 61.5 Total length from panel surface including relay socket length from panel surface including Total SH4B-05: 61.5 Total length from panel surface including relay socket length from panel surface including Total

38 43.2 RH4B-U/RH4B-UL/RH4B-UD/RH4B-ULD RH4B-U/RH4B-UL/RH4B-UD/RH4B-ULD RH1B-U/RH1B-UL/RH1B-UD/RH1B-ULD RH3B-UT Below 100V DC 100V DC and over With Indicator LED & Diode (-LD type) LED & Diode Indicator With Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 780 RH Standard DINRailMountSockets SH3B-05 SH1B-05 RH3V2-U/RH3V2-UL/RH3V2-D RH1V2-U/RH1V2-UD 2.5 67 2.5 67 20 16 17 8 40 36 32 35.6 max. 35.6 max. M3 Screw 8 4.2 M3.5 Screw 0.5 T erminal 4.2 T erminal Screw M3.5 Terminal 0.5

0.5 2 4.6 47 4.6 0.5 1.5 2 25 47 31.5 14.5 18 13 13 9 5 1 14 9 5 1 14 (For terminals1,5,and9) 31 10 6 2 7.9 max. 4.4 max. 25 31.5 14.5 (BNDN) DIN Rail 18

11 27.5 8 4 14 11-ø2.4 holes 27.5 (BNDN) DIN Rail 4.4 max. 7.9 max. 5.5 min. 16 ø3.6 min. (or M4 2-ø4.2 MountingHoles 7.8 (or M4TappedHoles) 2-ø4.2 MountingHoles 2-ø2 holes 36 Ta 5.9 max. 4 max. pped Holes) (For terminals13and14) 10 4.8 min. 7.15 4.4 10 ø3.6 min. 5.5 min. 3-ø2.4 holes Te ø3.2 min. Dimensions con’t (mm) Dimensions con’t rminal Terminal Arrangement ( T 7.25 op V 6.6 Arrangement 14 5 9 1 13 iew 13.15 4.7 12.5 4.7 ( Relays &Sockets www.IDEC.com 12 14 4 8 Top View ) 10 2 6 13 9 5 1 ) SH4B-05 SH2B-05 RH4V2-U/RH4V2-UL/RH4V2-UD RH2V2-U/RH2V2-UL/RH2V2-UD 2.5 67 2.5 67 30 26 22 8 35.6 max. 42 50 46 35.6 max. 0.5 0.5

8 4.2 Screw M3.5 Terminal

4.2 Screw M3.5 Terminal

4.6 0.5 2 0.5 2 2 4.6 47 5 0.5 13 9 5 47 1 31.5 25 14.5 18 10 6 2 41 13 9 5 1 31.5 21 25 11 7 3 14.5 18 12 14 8 4 12 8 4 (BNDN) DIN Rail 14

4.4 max. 27.5 7.9 max. 14-ø2.4 holes (BNDN) DIN Rail 27.5 4.4 max. 7.9 max. 7.8 (or M4TappedHoles) 2-ø4.2 MountingHoles 26 (or M4TappedHoles) 2-ø4.2 MountingHoles 46 5.5 min. ø3.6 min. 7.8 8-ø2.4 holes 10 30 ø3.6 min. 5.5 min. 14.2 10 Terminal Arrangement Terminal Arrangement ( Top View 14 12 4 8 12 14 ( 4 8

Top View 7.25 7.25 11 3 13 7 1 5 9 13.15 4.7 13.15 4.7 10 2 6 ) ) 13 1 5 9 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RH 781 t ) 9 5 1 13 9 3 5 1 1 ) 8 4 0 6 2 14 12 1 Top View ( 1 7 3 1 Top View ( 8 2 4 4 1 1 Terminal Arrangemen Terminal Arrangement (or M4 Tapped Holes) 46 2-ø4.2 Mounting Holes 26 2-ø4.2 Mounting Holes (or M4 Tapped Holes) ) Ring terminals cannot be used. Ring type crimping terminals cannot be used. BNDN DIN Rail ( DIN Rail (BAA/BAP) 18.7 18.7 25 25 36 29.5 29.5

When using BAA/BAP: 33

49

49

4.2 ø5

7 2 4.

M3.5 Terminal Screw

5 ø 46 50 42 7

22 26 30

69 7 1.

1.7 69 SH2B-51 SH4B-51 SH2B-05C SH4B-05C

) ) 1 5 9 13 13 USA & Canada 1 9 5 6 2 • 10 14 8 4 Top View 14 12 Top View ( ( Dimensions con’tDimensions (mm) Terminal Arrangement Terminal Arrangement Relays & Sockets & Relays 36 (or M4 Tapped Holes) 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 2-ø4.2 Mounting Holes 16 800-262-IDEC (4332) ) Ring terminals cannot be used. Ring terminals cannot be used. BNDN DIN Rail ( DIN Rail (BNDN) 18.7 25 36 29.5

18.7 25 36

29.5

49

48

4.2 5

M3.5 Terminal Screw ø

7 4.2

M3 Terminal Screw M3.5 Terminal Screw 5

36 40 32 ø

7 16 20 17

69

1.7 1.7 69 SH3B-51 SH1B-51 SH3B-05C SH1B-05C Through Panel Mount Socket Finger-safe DIN Rail Mount Sockets Rail Mount Sockets DIN Finger-safe Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 782 RH PCB MountSockets SH3B-62 SH1B-62 31 31 12.2 18 30.2 36 2 1.5 2 11 15 3 11 3 15

0.3 0.3 25.4 25.4 Terminal Arrangement Terminal Arrangement (Bottom View) 13 (Bottom View) 1 5 1 9 1 5 9 3 14 1 6 2 0 hold-downsprings * 36min.whenusing 12 1 4 8 4 hold-downsprings * 36min.whenusing 3- ø2.4 holes 31 min.* 12.5 4.7 7.35 4.7 6.65 31 min.* 11.85 6.95 6.6 5.95 10 6.8 21.3 Dimensions con’t (mm) Dimensions con’t 36 min. 10 4.4 2- (Tolerance ±0.1) ø2 holes 11- (Tolerance 0.1) 18 min. ø2.4 holes Relays &Sockets www.IDEC.com SH4B-62 SH2B-62 31 29 2 21.2 2 39.2 45 11 15 3 11 3 15

0.3 0.3 25.4 25.4 Terminal Arrangement hold-downsprings * 36min.whenusing Terminal Arrangement 1 5 1 9 3 (Bottom View) 1 6 2 0 (Bottom View) 1 3 7 1 1 3 5 1 9 1 1 4 8 4 2 1 1 4 8 2 4 hold-downsprings * 34min.whenusing

31 min.* 12.5 4.7 6.85 6.65 6.6 4.7

29 min.* 12.5 5.65 2.85 10

31.3 6.6 10 45 min. 10 15.5 10 (Tolerance 0.1) 14-ø2.4 holes (Tolerance 0.1) 8-ø2.4 holes 21.5 min. Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RR 783 Coil Voltage Code Coil Voltage mounted using DIN rail BNDN1000. All DIN rail mount sockets shown above can be (Standard Stock Items in Bold) (Standard Stock Items in RR3B-U AC120V AC120V, AC110V, AC24V, AC12V, AC6V, AC240V, DC110V DC24V, DC48V, DC12V, DC6V, Part No. Coil Voltage Code Part No. Coil Voltage 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Ordering Information code: When ordering, specify the Part No. and coil voltage (example) Blade Terminal* RR1BA-UC RR1BA-ULC RR1BA-US RR2BA-U RR2BA-UL RR2BA-UC RR2BA-ULC RR3B-U RR3B-UL RR3B-UC RR3B-ULC RR1BA-UL RR3B-US RR1BA-U RR2BA-US Part Number 0 Through Panel Mount 0 0 0 0 0 0 0

SR3B-51 SR3P-51 SR2P-51 Pin Terminal RR3PA-U RR3PA-U RR3PA-UL RR3PA-UC RR3PA-ULC — — RR2P-U RR2P-UL RR2P-UC RR2P-ULC — USA & Canada • — Part Number Selection Number Part Power Relays Power RR Series Relays & Sockets & Relays Finger-safe DIN Rail Mount Finger-safe SR3P-05C SR2P-05C Model 800-262-IDEC (4332) Standard With Indicator With Check Button With Indicator and Check Button Side Flange Model Standard With Check Button With Indicator and Check Button Side Flange Model Standard With Indicator With Check Button With Indicator and Check Button Side Flange Model With Indicator Standard DIN Rail Mount SR3B-05 SR3P-05 SR3P-06 SR2P-05 SR2P-06 *Blade type not TUV tested or CE marked. Side flange model mounts directly to panel with no socket required. SPDT through 3PDT, 10A contacts 3PDT, SPDT through type relays Midget power terminal styles. in pin and blade Available and side flange. check button for test operations an indicator, Options include of mount sockets are available for a wide a variety DIN rail, surface and panel mounting applications. Relays Contact SPDT 3PDT DPDT • • • • • RR1BA RR2BA RR3B RR3PA RR2P Key features: Sockets RR Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 784 RR Accessories Hold DownSprings&Clips Spring Anchor Hold-Down Replacement Stop DIN RailEnd (1 meterlength) DIN Rail Aluminum Item Appearance Appearance Description (side latch) Leaf Spring Spring Pullover Wire Relay RR2P, RR3PA RR2P RR3B RR1BA, RR2BA, RR3PA SR2P-05(C), SR3P-05(C) Chair clipforsockets SR3B-05, SR2P-06,SR3P-06 Horseshoe clipforsockets DIN rail All DINrailsockets Use with Mount Socket For DIN SFA-203 SR2B-02F1 SR3B-02F1 SR3B-02F1 Relays &Sockets www.IDEC.com PCB MountSocket For ThroughPanel& – SR3P-01F1 SR3B-02F1 Y703-102 Y778-011 BNL5 BNDN1000 Part No. spring. 2piecesincludedwitheachsocket. For useonDINrailmountsocketwhenusingpulloverwireholddown 9.1 mmwide. length is39”(1,000mm). (10.5mm) inheightand1.37(35mm)width(DINstandard).Standard Made ofdurableextrudedaluminum,theBNDN1000measures0.413 The BNDN1000isdesignedtoaccommodateDINmountsockets. Remarks Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RR 785 10% minimum 30% minimum Dropout Voltage Pickup Voltage 80% maximum 80% maximum Measured using 5V DC, 1A voltage drop method Measured using 5V DC, 1A voltage (at 20°C), excluding contact Measured at the rated voltage bouncing conditions, refer to For use under different temperature Curve. Continuous Load Current vs. Operating Temperature 1. 2. 3. Operating Characteristics (values at 20°C) 110% 110% Applied Voltage Maximum Continuous 1500V AC, 1 minute 1500V AC, 1 minute 1500V AC, 1 minute 1000V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute 1000V AC, 1 minute 25 18 79 4.9 400 100 USA & Canada 8,460 1,600 1,680 2,100 8,330 • (100g) 2 (10G) 2 ±10% (at 20°C) Coil Resistance (Ω) 1800 operations/h maximum 18,000 operations/h maximum 10 to 55 Hz, amplitude 0.5 mm 10 to 55 Hz, amplitude 0.5 mm 1000 m/s 100 m/s Relays & Sockets & Relays 23 420 210 105 10.5 20.5 60 Hz 800-262-IDEC (4332) 13 30 60 120 240 –25 to +40°C (no freezing) 5 to 85% RH (no condensation) 82g 96g, RR1BA/RR2BA/RR3B: RR2P: 90g, RR3PA: Silver 25 ms maximum 25 ms maximum (60 Hz) Hz), 2.5 VA (50 AC: 3 VA DC: 1.5W megger) 100 MΩ minimum (500V DC Between live and dead parts: Between contact and coil: poles: Between contacts of different pole: Between contacts of the same Between live and dead parts: Between contact and coil: Between contacts of different poles: Between contacts of the same pole: Electrical: Mechanical: Damage limits: Operating extremes: Damage limits: 30 mΩ maximum 1V DC, 10 mA 10,000,000 operations 200,000 operations (220V AC, 5A) Operating extremes: 27 24 490 245 121 12.1 50 Hz Rated Current (mA) ±15% (at 20°C) 3 1 Pin Terminal 2 2 Blade Terminal 6 6 48 24 12 12 24 110 110 120 240 AC DC Rated Voltage (V) Rated Voltage (50/60 Hz) Operating Humidity (approx.) (Standard type) Weight Dielectric Strength Release Time Power Consumption (approx.) Insulation Resistance Operating Frequency Vibration Resistance Shock Resistance Contact Material Contact Resistance Minimum Applicable Load Minimum Applicable Operating Time Mechanical Life Electrical Life Operating Temperature

Coil Ratings Specifications Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 786 RR

TÜV Ratings Contact Ratings Socket Specifications Sockets DIN Rail Sockets Panel Mount Through Continuous Current 240V AC Voltage 30V DC 10A Note: Inductiveloadfortherated—cosø=0.3,L/R7ms Allowable ContactPower 1650VA AC 300W DC Resistive Load SR3P-05C SR2P-05C SR3B-51 SR3B-05 SR3P-51 SR3P-06 SR3P-05 SR2P-06 SR2P-05 SR2P-51 Relays 10A 10A Maximum ContactCapacity 1100VA AC 150W DC Inductive Load Solder Solder M3 screwwithcaptivewireclamp M3 screwwithcaptivewireclamp,fingersafe M3 screwwithcaptivewireclamp M3 screwwithcaptivewireclamp M3 screwwithcaptivewireclamp,fingersafe M3 screwwithcaptivewireclamp M3 screwwithcaptivewireclamp Solder AC: cosø=1.0,DC:L/R0ms Voltage (V) 220 AC 110 AC 30 DC Terminal Rated Load Res. Load 7.5A 10A 10A Ind. Load 7.5A 5A 5A Relays &Sockets www.IDEC.com 300V, 10A 300V, 10A 300V, 10A 300V, 10A 300V, 10A 300V, 10A 300V, 10A 300V, 10A 300V, 15A(10A)*(*CSArating) 300V, 10A CSA Ratings UL Ratings 120V AC 240V AC Voltage 30V DC Electrical Rating 240V AC 100V DC 120V AC Voltage 30V DC Resistive 10A 10A 10A Maximum 2-#12AWG Maximum 2-#12AWG Maximum 2-#12AWG Maximum 2-#12AWG Maximum 2-#12AWG Maximum 2-#12AWG Maximum 2-#12AWG Resistive 10A 10A 10A — General use Wire Size 7.5A 7A 7A — — — Horse PowerRating General use 9 -11.5in•lbs 9 -11.5in•lbs 9 -11.5in•lbs 9 -11.5in•lbs 9 -11.5in•lbs 9 -11.5in•lbs 9 -11.5in•lbs 0.5A 7.5A 7.5A 1/4 HP 1/3 HP Torque 7A — — — — Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RR 787 10 5 Coils below 100V use LED indicator while coils above 100V use neon lamp indicator. An LED protection diode is not contained in relay coils below 100V DC. • When the relay is energized, the indicator goes on. • 30V DC resistive Front Pushbutton 10 9 30V DC inductive 8 1 DC Coil 7 6 0.5 5 With Check Button Contacts can be operated by pressing the check button. 4 RR3B AC Coil Load Current (A) 3 2 Load Current (A) 0.1 1 0

90 80 70 60 50 40 30 20 10

0.05 100 Operating Temperature (C) Temperature Operating RR3B-U 100V DC resistive 100V DC inductive 0.01 50 20 10

500 100

1000 Life (¥ 10,000 operations) 10,000 (¥ Life RR2BA Continuous Load Current vs. Operating Temperature Curve vs. Operating Temperature Continuous Load Current Button, and Side Flange Type) With Check (Standard Type, DC Load RR2BA-U USA & Canada • RR1BA Relays & Sockets & Relays 300 Characteristics (Reference Data) (Reference Characteristics RR1BA-U 200 10 100 5 AC inductive AC resistive 800-262-IDEC (4332) 50 RR3PA 30 1 Load Voltage (V) Load Current (A) DC inductive DC resistive 10 0.5 RR3PA-U 5 1 110V AC resistive 220V AC resistive 110V AC inductive 220V AC inductive

5.0 1.0 0.5

10.0 0.1 (A) Current Load 50 20 10

500 100

1000 RR2P Life (¥ 10,000 operations) 10,000 (¥ Life RR2P-U Coil 100V AC/DC and over Coil Below 100V AC/DC With Indicator (-UL type) Internal Connection (View from Bottom) Standard Type Maximum Switching Capacity Maximum Switching Electrical Life Curves Electrical AC Load Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 788 RR Standard DINRailMountSockets SR3P-05 SR2P-05 RR2BA-UL/RR3B-U/RR3B-UL RR1BA-U/RR2BA-UL/RR2BA-U RR2P-U/RR2P-UL 3 52 3 52 8 29 36 34 42 8 Total lengthfrompanelsurfaceincludingrelaysocket SR3B-05: 73(76)max.,SR3B-51:56(60)max. Screw M3.5 Terminal Total lengthfrompanelsurfaceincludingrelaysocket SR2P-05: 84.5(87.5)max.,SR2P-511:63(68)max. 47.5 max. ø4.2 hole ø4.2 hole Screw M3.5 Terminal

33 33

ø25 55.5 max. ø27 28.5 7.3 35 16.5 20 28.5 35 16.5 20 0.5 3.0 ¥ø2.0oblonghole 4.7 9.9 (BNDN) DIN Rail 13 include ahold-downspring. Dimensions inthe() (BNDN) DIN Rail 4.4 max. A 7.9 max. 4.4 max. 7.9 max. 7 4 1 (or M4TappedHoles) 2-ø4.2 MountingHole 2-ø4.2 MountingHoles 36 (or M4TappedHoles) 34 include ahold-downspring. Dimensions inthe( 8 5 2 29 9 6 3 2 3 B 28.6 5 min. 1 45 ø3.6 min. 5 min. ø3.6 min. 8

36 7 6 ) Terminal Arrangement Terminal Arrangement 35.6 Dimensions (mm) ( 10 ( Top View 9 7 8 6 5 8 7 Top View RR1BA-US/RR2BA-US/RR3B-US 11 6 Relays &Sockets www.IDEC.com 1 4 1 2 3 ) 4 2 ) 3 5

16.0 4.2 SR3P-06 SR2P-06 RR3PA-U/RR3PA-UL 1 60 160 33 8 40 33 59 8 47.5 max. Total lengthfrompanelsurfaceincludingrelaysocket SR3P-05: 84.5(87.5)max.,SR3P-511:63(68)max. 63.5 73.5 ø4.2 hole Screw M3.5 Terminal ø4.2 hole Screw M3.5 Terminal 55.5 max. 7.3

ø25 16.1

ø27 0.5 22 25.5 18 4.7

11.1 11.1 3.0 ¥ø2.0oblonghole 22 28.5 18 9.9 13 (BNDN) DIN Rail A 7 4 1 4.9 max. 7.9 max. 4.9 max. 7.9 max. (BNDN) DIN Rail 36 8 5 2 (or M4TappedHoles) 2-ø4.2 MountingHoles include ahold-downspring. Dimensions inthe( (or M4TappedHoles) 2-ø4.2 MountingHoles 33 33 9 6 3 3 B 4 2 5

36 1 35.6 6 5 min. ø3.6 min. 5 min. ø3.6 min. 11 2-ø4.5 MountingHoles 7 10 8 ) 9 Terminal Arrangement Terminal Arrangement 63.5 87 9 35.6 10 7 6543 ( ( Top View Top View 11 8 65 1 12 2 ) ) 4 3 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RR 789 ) 5 3 2 4 1

6 11 38 Top View 8 7 9 ( 10

2-ø3.5 Mounting Holes (or M3 Tapped Holes)

Terminal Arrangement ø30 9 8 10 7 11 6 1 34 5 (or M4 Tapped Holes) 2 2-ø4.2 Mounting Holes 4 3 Ring type crimping terminals cannot be used. (Bottom View) DIN Rail (BNDN) Terminal Arrangement 21.5 30 11 36.5

10

Surfarface

2.5 Panel

2.5

ø29

5 ø4.2 hole

6 ø 7 34 34 42

4.2

38

50 58 2.2 SR3P-51 SR3P-05C

) ) 1 4 7 A 3 2 1 4 5 2 8 USA & Canada

• 3 38 9 6 B Top View

( 7 8 5 6 Top View

(

43 (Tolerance 0.3) 32.5

2-ø3.5 Mounting Holes (or M3 Tapped Holes)

Terminal Arrangement 2-ø4.2 Mounting Holes (M4 Tapped Holes) Terminal Arrangement ø30 Relays & Sockets & Relays 22 35.5*

5.5 min. ø3.6 min. 11.5 min. 11.5 L = 38 (N – 1) + 35.5 When two or more sockets are mounted side by side: N: No. of sockets mounted 6.75 * 37 7 6 29 2-ø4.2 Mounting Holes (or M4 Tapped Holes) (or M4 Tapped Holes) 5 8 2-ø4.2 Mounting Holes 800-262-IDEC (4332) 1 4 2 3 3 6 9 B 7.9 max. (Bottom View) DIN Rail (BNDN) Ring type crimping terminals cannot be used. 4.4 max. 2 5 8 1 4 7 A Terminal Arrangement DIN Rail (BNDN) (Bottom View) Terminal Arrangement 14.5 25 31.5 11

21.5

30

36.5 32

10

Surfarface

0.3

56 2.5

11 max. Panel 6.5 ø29 2.5

3 M3.5 Terminal Screw 6

ø4.2 hole

7.5 ø5 4.2 43

7 35 34 8 29 36 37 43 3.5 36

4.2 22 38 35

38

50 2.2 58 51.5 76 2 SR3B-51 SR2P-51 SR2P-05C SR3B-05 Through Panel Mount Socket Finger-safe DIN Rail Mount Sockets DIN Rail Mount Finger-safe Standard DIN Rail Mount Sockets Standard Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 790 RU Standard (withoutlever) With Latching orMomentaryLever Key features: • • • • • • • • • • • UL Recognized,CSACertified,ENCompliant Maximum contactratings:10A(RU2),6A(RU4),3A(RU42) Snap-on yellowmarkingplate;optionalplatesareavailableinfourother colors Manual latchingleverwithcolorcodingforACorDCcoil Mechanical flagindicator Cadmium-free contacts No internalwires,lead-freeconstruction Non-polarized LEDindicator Two terminalstyles:plug-inandPCBmount Designed withenvironmenttakenintoconsideration Full featureduniversalminiaturerelays provision forplug-interminaltypes. Non-polarized greenLEDindicatorisstandard LED Indicator* Marking Plate Mechanical Indicator* types provision forplug-interminal,latchinglever Non-polarized greenLEDindicatorisstandard LED Indicator* easy identificationofrelays. with optionalmarkingplatesinfourcolorsfor Standard yellowmarkingplateiseasilyreplaced Marking Plate the fivesmallwindows. The contactpositioncanbeconfirmedthrough Mechanical Indicator* *Not availableonPCBtype. For identificationofACorDCcoils. AC/DC ColorMarking

AC Coil EN61810-1 RU Series Universal Relays DC coil:Blue AC coil:Yellow

Relays &Sockets www.IDEC.com DC Coil ing thecoil.TheleveriscolorcodedforACandDCcoils. Using thelever, operationcanbecheckedwithoutenergiz Latching andMomentaryLever Note: Turn offthepowertorelaycoilwhenusinglatching in thenormalposition. lever. Aftercheckingtheoperation,returnlatchinglever DC coil: AC coil: 110V DC 48V DC 12V DC 6V DC 24V DC 220 to240VAC 200 to220VAC 110 to120VAC 100 to110VAC 24V AC Coil Voltage In NormalOperation Green Orange Latching Blue Red Momentary yellow tape Voltage markingon Green Red Black Blue Clear White Tape Color - Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RU 791 Coil Voltage Code Coil Voltage (Standard Stock in bold) (Standard Stock A24, A110, A220 D6, D12, D24, D48, D110 A24, A110, A220 D6, D12, D24, D48, D110 A24, A110, A220 D6, D12, D24, D48, D110 A24, A110, A220 D6, D12, D24, D48, D110 A110, A220 D6, D12, D24, D48, D110 A24, A110, A220 D6, D12, D24, D48, D110 A110, A220 D6, D12, D24, D48, D110 A24, A110, A220 D6, D12, D24, D48, D110 A110, A220 D6, D12, D24, D48, D110 RU2S-C A110 0 0 0 0 0 0 0 0 0 D110 110V DC — — — Part No. Coil Voltage Code Part No. Coil Voltage RU2S-M- RU4S-M- RU42S-M- RU2S-MR- RU4S-MR- RU2S-MD- RU4S-MD- RU42S-MR- RU42S-MD- D48 With Momentary Lever With Momentary 48V DC PCB Mount Ordering Information code: When ordering, specify the Part No. and coil voltage (example) SY4S-61 SY4S-62 SM2S-61 SM2S-62 0 0 0 0 0 0 0 D24 0 0 24V DC — ­— — RU2S- RU4S- RU42S- RU2S-R- RU4S-R- RU2S-D- RU4S-D- RU42S-R- RU42S-D- Part Number Panel Mount With Latching Lever With Latching D12 SY4S-51 12V DC USA & Canada • D6 0 0 0 0 0 6V DC 0 0 0 0 0 0 0 Part Number Selection Number Part Rail Mount Relays & Sockets & Relays Finger-safe DIN Finger-safe Standard RU4S-C- RU2S-C- SY4S-05C SM2S-05C RU42S-C- RU2V-NF- RU4V-NF- RU2S-CR- RU4S-CR- RU2S-CD- RU4S-CD- RU42V-NF- RU42S-CR- RU42S-CD- A220 220-240V AC 800-262-IDEC (4332) Rail Mount Standard DIN A110 SY4S-05 SM2S-05 110-120V AC Model A24 With RC (AC coil only) With diode (DC coil only) PCB With RC (AC coil only) With diode (DC coil only) PCB With RC (AC coil only) With diode (DC coil only) PCB Standard Standard Standard 24V AC Spring Clamp DIN Rail Mount SU4S-11L SU2S-11L Plug-in terminal models have an LED indicator and a mechanical indicator as standard. Plug-in terminal models have an LED indicator and a mechanical PCB models do not have an LED indicator or a mechanical indicator. 2. 1. Relays RU4S (4PDT) RU42S (4PDT) DPDT (10A) Coil Rating RU2S (DPDT) Contact 4PDT (6A) 4PDT Bifurcated (3A) Coil Voltage Code Coil Voltage

Sockets Coil Voltage Table Coil Voltage Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 792 RU

Specifications Accessories Hold DownSprings&Clips

Appearance Mechanical Life Dielectric Strength Insulation Resistance Power Consumption Release Time Weight Operating Humidity Temperature Operating Contact Material Applicable Load Minimum Electrical Life Shock Resistance Vibration Resistance Operating Frequency Contact Resistance Operating Time Marking Plate Name 3. 2. 1. Specifyacolorcodewhenordering.Themarkingplatecanberemovedfromtherelaybyinserting Model (Contact) Measured attheratedvoltage(at20°C),excluding contactbouncing; Measured atoperatingfrequencyof120operations/min (failureratelevelP, referencevalue) Measured using5VDC,1Avoltagedropmethod a flatscrewdriverunderthemarkingplate. 5 3 Release timeofDCrelayswithdiode: Release timeofACrelayswithRC:

4 3 2 Part Number 1 Item (top latch) Leaf Spring (side latch) Leaf Spring Spring Pullover Wire RU9Z-P* 2500V AC,1minute (reference value) 24V DC,5mA RU2 (DPDT) AC: 1.1to1.4VA (50Hz),0.9to1.2VA (60Hz)DC:0.9to1.0W Silver alloy A (orange),G(green),S(blue),W(white),Y(yellow) DC: 100,000,000operations Relay RU42S RU2S/RU4S/ RU42S RU2S/RU4S/ RU42S RU2S/RU4S/ Between contactsofthesamepole:1000VAC,1minute AC: 50,000,000operations Operating extremes:10to55Hz,amplitude0.5mm Between contactandcoil:2500VAC,1minute Damage limits:10to55Hz,amplitude0.5mm Mechanical: 18,000operations/hmaximum Blade model:–55to+60°C(nofreezing) Electrical: 1800operations/hmaximum PCB model:–55to+70°C(nofreezing) Between contactsofdifferentpoles: 100MΩ minimum(500VDCmegger) Operating extremes:150m/s Damage limits:1000m/s 5 to85%RH(nocondensation) 40 msmaximum 25 msmaximum Silver (goldclad) See tableonpage794 Color Code* 1V DC,1mA RU4 (4PDT) 50 mΩmaximum 20 msmaximum 20 msmaximum Mount Socket For DIN SFA-101* SFA-202* SY4S-02F1 Approx. 35g 2000V AC,1minute 2 RU42 (4PDT-bifurcated) (100G) Silver-nickel (goldclad) 50,000,000 operations 2 Relays &Sockets www.IDEC.com (15G) 1V DC,0.1mA Mount Socket Panel &PCB For Through SFA-301* SFA-302* SY4S-51F1 5. 4. Measured attheratedvoltage. Contact LoadandElectricalLife(atambienttemperature 20°C) Note: Order2piecesforeachrelay Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RU 793 — — 1.5A 0.8A RU42 RU42 RU4 1.5A 0.8A — RU4 Inductive 1/10HP 5A 5A RU2 30% minimum 10% minimum Dropout Voltage — — Horse Power Rating RU2 3A 3A RU42 — — RU42 6A 6A RU4 Resistive — 6A RU4 10A 10A RU2 General Use — — RU2 Pickup Voltage 80% maximum 80% maximum 30V DC 3A 3A Voltage 250V AC TÜV Ratings RU42 6A — RU4 Resistive 3A 3A RU42 Operating Characteristics (values at 20°C) Operating Characteristics 10A 10A RU2 Resistive Remarks The BNDN1000 is designed to accommodate DIN mount sockets. is designed to accommodate The BNDN1000 BNDN1000 measures 0.413 extruded aluminum, the Made of durable (DIN standard). Standard and 1.37 (35mm) in width (10.5mm) in height length is 39” (1,000mm). 9.1 mm wide. when using pullover wire hold down For use on DIN rail mount socket each socket. spring. 2 pieces included with 110% 110% 30V DC 30V DC Voltage Voltage 250V AC 250V AC Applied Voltage UL and c-UL Ratings CSA Ratings Maximum Continuous Part No. BNDN1000 BNL5 Y778-011 5A 5A 0.8A 1.5A 0.8A 1.5A Ind. Load 40 164 160 605 USA & Canada 4,550 2,560 18,230 12,100 Rated Load • 6A 6A 3A 3A 10A 10A ±10% (at 20°C) Res. Load Coil Resistance (Ω) Relays & Sockets & Relays (V) Ratings Voltage Voltage 250 AC 30 DC 250 AC 30 DC 30 DC 250 AC 42.5 60 Hz 7.1-8.2 3.6-4.2 Use with All DIN rail sockets DIN rail Horseshoe clip for DIN rail sockets 80 18 8.9 155 44.7 800-262-IDEC (4332) ±15% (at 20°C) Inductive Load 1250VA AC 1250VA 150W DC 600VA AC 600VA 90W DC 45W DC 200VA AC 200VA 49.3 50 Hz 4.2-5.0 Rated Current (mA) 8.4-10.0 Diode reverse voltage: 1000V Diode forward current: 1A RC series circuit R: 20 kΩ, C: 0.033 µF Maximum Contact Capacity D6 A24 D12 D24 D48 Coil Allowable Contact Power A110 D110 A220 Code Resistive Load 2500VA AC 2500VA 300W DC 1500VA AC 1500VA 180W DC 90W DC 750VA AC 750VA Voltage Voltage With Diode With RC Appearance 6 6A 3A 24 12 24 48 10A 110 Model Current 110-120 220-240 Continuous On 4PDT relays, the maximum allowable total current of neighboring two poles is 6A. At the rated On 4PDT relays, the maximum allowable total current of neighboring two poles is 6A. At the rated load, make sure that the total current of neighboring two poles does not exceed 6A (3A + 3A = 6A). Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms The rated current includes the current of the LED indicator. 2. 1. 1. AC DC Rated Voltage (V) Rated Voltage 4PDT 4PDT DPDT Contact (50/60 Hz) bifurcated DC Coil Item Aluminum DIN Rail (1 meter length) AC Coil DIN Rail End Stop Replacement Hold-Down Spring Anchor

Contact Ratings Surge Suppressor Ratings Coil Ratings Accessories

Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 794 RU Maximum SwitchingCurrent Electrical LifeCurves Socket Specifications RU2 RU2 (InductiveLoad) RU2 (ResistiveLoad) Sockets DIN RailMount PCB MountSocket Load Current (A) Mount Socket Through Panel 0.1 10 1000 1 5 (¥ 10,000 operations) (¥ 10,000 operations) 1000 100 100 10 10 1 1 DC: L/R=7ms AC: cosø=0.3 L/R =7ms DC inductive DC resistive 10 Load Voltage(V) 0.1 0.1 110V DC 250V AC/30VDC Load Current(A) 30 Load Current(A) 110V DC 30V DC 250V AC Sockets SM2S-05 SU4S-11L SU2S-11L SM2S-05C SY4S-05 SY4S-62 SY4S-61 SY4S-51 SY4S-05C 100 0.5 0.5 250 1510 1 AC resistive 500 (cos ø=0.3) AC inductive Terminal M3 screwwithcaptivewireclamp Spring clampterminals Spring clampterminals M3 screwwithcaptivewireclamp,fingersafe M3 screwwithcaptivewireclamp PCB mount PCB mount Solder M3 screwwithcaptivewireclamp,fingersafe 5 10 RU4 (InductiveLoad) RU4 (ResistiveLoad) RU4

(¥ 10,000 operations) (¥ 10,000 operations) 1000 100 100 10 10 1 1 0.02 DC: L/R=7ms AC: cosø=0.3 0.1 Load Current(A) 0.1 Relays &Sockets www.IDEC.com 110V DC 30V DC 250V AC Load Current(A) 110V DC 30V DC 250V AC Electrical Rating 300V, 10A 250V/6A (usingRU4),10ARU2) 250V/10A 300V, 10A 300V, 7A(usingRU4),10ARU2) 250V, 7A 300V, 7A 300V, 7A 300V, 7A(usingRU4),10ARU2) 0.5 0.5 1 3 6 RU42 (Bifurcated) RU42 (InductiveLoad) RU42 (ResistiveLoad) (¥ 10,000 operations) (¥ 10,000 operations) 100 100 10 10 1 1 Wire Size Maximum upto2–#14AWG 24-16 AWG 24-16 AWG Maximum upto2–#14AWG Maximum upto2–#14AWG Maximum upto2–#14AWG 0.02 0.02 DC: L/R=7ms AC: cosø=0.3 — — — 0.1 0.1 110V DC 30V DC 250V AC Load Current(A) Load Current(A) 110V DC 30V DC 250V AC 0.5 0.5 1 Torque 5.5 -9in•lbs 5.5 -9in•lbs 5.5 -9in•lbs 5.5 -9in•lbs 3 — — — — — 6 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RU 795 0 70 07 60 06 50 05 40 No load current No load current 04 30 Load current 6A ¥ 2 poles Ambient Temperature (C) 03 Ambient Temperature (C) 20 Load current 10A ¥ 2 poles 02 10 Load current 3A ¥ 4 poles Load current 5A ¥ 2 poles 01 0

90 80 70 60 50 40 30 20 10 90 80 70 60 50 40 30 20 10

110 100 120

120 110 100 Temperature Rise (C) Rise Temperature Temperature Rise (C) Rise Temperature RU4/RU42 (DC Coil) RU2 (DC Coil) 0 70 07 60 06 50 05 40 No load current 04 No load current 30 Load current 6A ¥ 2 poles 03 Ambient Temperature (C) Ambient Temperature (C) 20 USA & Canada • Load current 10A ¥ 2 poles 02 10 Load current 3A ¥ 4 poles Load current 5A ¥ 2 poles 01 0 90 80 70 60 50 40 30 20 10

Relays & Sockets & Relays 90 80 70 60 50 40 30 20 10

110 100 120

120 110 100 Temperature Rise (C) Rise Temperature Temperature Rise (C) Rise Temperature RU4/RU42 (AC Coil, 60 Hz) RU4/RU42 (AC Coil, RU2 (AC Coil, 60 Hz) RU2 (AC Coil, 800-262-IDEC (4332) 0 70 07 60 06 50 05 40 No load current No load current 04 30 Ambient Temperature (C) 03 Ambient Temperature (C) 20 Load current 6A ¥ 2 poles 02 10 Load current 10A ¥ 2 poles Load current 3A ¥ 4 poles Load current 5A ¥ 2 poles The above temperature rise curves show the characteristics when 100% the rated coil voltage is applied. 100% the rated coil voltage is applied. The above temperature rise curves show the characteristics when for the coil at different ambient temperatures. indicates the allowable temperature rise The heat resistance of the coil is 120°C. The slant dashed line Load current 6A x 2 poles is for the RU4 models only. 0 01

90 80 70 60 50 40 30 20 10 90 80 70 60 50 40 30 20 10

120 110 100 110 100 120 Temperature Rise (C) Rise Temperature Temperature Rise (C) Rise Temperature RU4/RU42 (AC Coil, 50 Hz) RU4/RU42 (AC Coil, RU2 (AC Coil, 50 Hz) RU2 (AC Coil, Ambient Temperature vs. Temperature Rise Curves vs. Temperature Temperature Ambient Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 796 RU Internal Connection(Viewfrom Bottom) RU4S-*/RU42S-* Standard RU2S-* Standard

24V 24V 24V Over 24V Over 24V (5)14 (5)14 (13)A1 (13)A1 (5)14 (5)14 (13)A1 (13)A1 (1)12 (1)12 (9)1 (9)1 (1)12 (1)12 (9)1 (9)1

AC/DC coilorless AC/DC coil or less or coil AC/DC 1 1 1 1 (6)24 (6)24 (10)21 (10)21 (2)22 (2)22 AC/DC coil AC/DC coil (7)34 (7)34 (1 (1 (3)32 (3)32 1)31 1)31 RU2S (8)44 (8)44 (12)41 (12)41 (8)44 (8)44 (14)A2 (4)42 (4)42 (12)41 (12)41 (14)A2 (14)A2 (14)A2 (4)42 (4)42 Removal Slot Marking Plate Insert aflatscrewdriverintotheslottoremovemarking Marking plateremovalslotisprovidedonlyononeside. DC: Green AC: Orange Lever Latching plate. Mechanical IndicatorWindow

21.0 RU4S-*R/RU42S-*R WithRC RU2S-*R withRC 14

27.5 5 8 0.5 Marking Plate(yellow) 912 (5)14 (13)A1 (5)14 (1)12 (9)11 13 14 (13)A1 (1)12 (9)11 (6)24 (10)21 ø1.2 ¥2.2Hole (2)22

6.4 35.0 (green) LED Indicator (7)34 (11)31 (3)32 (8)44 (12)41 (14)A2 (8)44 (4)42 (12)41 (14)A2 (4)42 2.6

Dimensions (mm) Relays &Sockets www.IDEC.com RU4S-*D/RU42S-*D WithDiode RU2S-*D WithDiode RU2V Removal Slot Marking Plate

A Color Marking DC: Blue 24V DC coil or less or coil DC 24V (5)14 (13)A1 Over 24VDCcoil C: Yellow 24V DCcoilorless (5)14 (13)A1 (5)14 (5)14 Over 24VDCcoil (13)A1 (1)12 (9)1 (1)12 (9)1 (13)A1 (1)12 (1)12 (9)1 (9)1 1 1 1 1 (6)24 (6)24 (10)21 (10)21 (2)22 (2)22 Mounting HoleLayout

4.1 21.0 (7)34 (7)34 (1 (1 (3)32 (3)32 1)31 1)31 7.0 (8)44 (8)44 (12)41 (12)41 (14)A2 (14)A2 (8)44 (8)44 (4)42 (4)42 (12)41 (12)41 (4)42 (4)42 (14)A2 (14)A2 27.5 0.5 Marking Plate(yellow) 12.7 6.4 8-ø1 Holes 13.2 4.0 35.0 All dimensionsinmm. RU4V-NF-*/RU42V-NF-* RU2V-NF-* 13.2 2.6 0.8 (5)14 (13)A1 (5)14 (13)A1 (1)12 (9)11 (1)12 0.5 (9)11 (6)24 (10)21 (2)22 (7)34 (11)31 (3)32 (8)44 (8)44 (12)41 (14)A2 (12)41 (4)42 (4)42 (14)A2 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers RU 797 ) ) 9 5 9 5 1 13 13 iew 6 21 6 2 10 10 7 3 11 7 p V 11 Arrangement 8 4 14 12 Top View To 8 43 ( 14 12 ( rminal

Terminal Arrangement

Te 0.5 ø3.2 min. 4.8 min. 3-4.4 0.8 2.6 2-ø3.2 Mounting Holes

26 2-ø4.2 Mounting Holes (or M4 Tapped Holes) Ring terminals cannot be used.

13.2 All dimensions in mm.

5.9 max. 4 max.

4.4 24.0

35.0 4.0 14-ø1 Holes 14-ø1 DIN Rail (BNDN) 6.4

12.7 37.5 18 18.5 25 31.5 Marking Plate (yellow) Plate Marking

27.5 0.5 45 38.3 32 7.0

4.1 21.0

Mounting Hole Layout M3 Terminal Screw 4.2 6 31 C: Yellow Marking Plate Removal Slot 26 DC: Blue Color Marking A 30

RU4V/RU42V

28.8 4.4

80 0.7 62 3 SY4S-05 SU4S-11L

) 9 5 1 13 ) 9 5 1 13 USA & Canada • 8 4 Top View 14 12

( Top View Top 8 4 14 12 ( 2.6 Terminal Arrangement Dimensions con’tDimensions (mm) Terminal Arrangement Terminal

Relays & Sockets & Relays

0 35. 4 LED Indicator (green) 6.

ø3.2 min. 4.8 min. ø1.2 × 2.2 Hole

14 13

12 11 10 9 26 2-ø4.2 Mounting Holes (or M4 Tapped Holes)

2-ø3.2 Mounting Holes

7 6 5 8 800-262-IDEC (4332) 0.5

Ring terminals cannot be used.

27.5 Marking Plate (yellow) Plate Marking

4 3 2 1 5.9 max. 4 max.

24.0 DIN Rail (BNDN)

0 21. 18

18.5 25 31.5 Mechanical Indicator Window Indicator Mechanical 37.5 plate. Latching Latching Lever AC: Orange DC: Green

Marking plate removal slot is provided only on one side. Marking plate removal slot is provided slot to remove the marking Insert a flat screwdriver into the

Marking Plate Removal Slot 45 RU4S/RU42S 38.3 32 erminal T

Screw M3 4.2 6

31 26 30

28.8 4.4

3 62 0.7 80

SM2S-05 SU2S-11L Standard DIN Rail Mount Sockets Spring Clamp DIN Rail Mount Sockets Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 798 RU Through PanelMountSocket PCB MountSockets Finger-safe DINRailMountSockets

SY4S-51 SY4S-61 31 SM2S-61 SM2S-05C 31 31 1.6 64 21.2 27 21.2 21.2 27 27 26 30 6 1.5 1.5 2.4

ø

4.2 5.5 Screw M3 Terminal 11 3 15 11 3 15 11 3 18.7 1 to2 Panel Thickness: 0.3 2 0.3 0.3 25.4 46

25.4 Terminal Arrangement 25.4 35.5 29 Terminal Arrangement 25 18.2 18 (Bottom View) hold-downsprings * 19.2min.whenusing 1 1 9 5 3 Terminal Arrangement 1 (Bottom View) 6 2 0 1 hold-downsprings * 19.2min.whenusing 1 9 5 3 1 3 7 1 1 1 (Bottom View) 4 8 2 4 1 5 1 9 3 (BNDN) DIN Rail 1 1 1 6 2 0 4 8 cannot beused. Ring terminals 4 2 1 3 7 1 1 1 4 8 4 2 26 2-ø4.2 MountingHoles

14.2 min.* 16.8 (or M4TappedHoles) 10.4 14.2 min.* 16.8 4.1 * 10.4min.whenusinghold-downsprings +0.2 1.4 8.8 5.4 min.* 25.6 0 10.4 1.4 4.1 13.2 [27 (N–1)+21.4] 13.2 Dimensions con’t (mm) Dimensions con’t 4.4 N: No.ofsocketsmounted Terminal Arrangement 15- (Tolerance 0.1) (Tolerance 0.1) ø2 holes 9- 13.8 min. + 0.5 0 12 14 ø2 holes 4 8 ( Top View 13.8 min. Relays &Sockets www.IDEC.com 13 1 5 9

9 ) 9

SY4S-62 SM2S-62 SY4S-05C 29 29 1.6 64 21.2 21.2 1.5 1.5 26 30 6 3

ø 3 Screw M3 Terminal 4.2 5.5 11 15 11 15

0.3 0.3 2 46 Terminal Arrangement Terminal Arrangement (Bottom View) 1 1 9 5 3 35.5 29 25 1 6 2 0 18.2 (Bottom View) 18 1 1 3 7 1 9 5 3 1 1 1 4 8 2 4 1 1 4 8 2 4 (BNDN) DIN Rail * * * the relaywithcheckbutton 13.2 min.whenusingahold-downspringfor 17.2 min.whenusingahold-downspring. cannot beused. Ring terminals

12.2 min.* 16.8 ** the relaywithcheckbutton. 13.2 min.whenusingahold-downspringfor *

10.4 17.2 min.whenusingahold-downspring. 1.4 4.4 4.1 26 2-ø4.2 MountingHoles

12.2 min.* 16.8 (or M4TappedHoles) 8.8 13.2 10.4 1.4 4.1 (Tolerance 0.1)

8.2 min.** 13.2 15-ø2 holes

9 Terminal Arrangement (Tolerance 0.1) 8.2 min.** 9-ø2 holes 12 14 4 ( 8 Top View 11 3 9 7 10 2 6 13 1 5 9 ) Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 799 RY/RM Coil Voltage Code Coil Voltage RY4S-U AC110-120V RY4S-U DC6V, DC12V, DC24V, DC48V, DC100-110V DC48V, DC24V, DC12V, DC6V, RYAC6V, AC12V, AC24V, AC110-120V, AC220-240V AC110-120V, AC24V, AC12V, RYAC6V, DC100-110V DC48V, DC24V, DC12V, DC6V, AC110-120V, AC24V, AC12V, AC6V, AC220-240V DC100-110V DC48V, DC24V, DC12V, DC6V, AC6V, AC12V, AC24V, AC110V, AC120V, AC120V, AC110V, AC24V, AC12V, AC6V, AC240V AC220V, DC110V DC48V, D24V, DC12V, DC6V, DC110V DC48V, DC24V, DC12V, DC6V, DC6V, DC12V, DC24V, DC48V, DC100-110V DC48V, DC24V, DC12V, DC6V, Part No. Coil Voltage Code Part No. Coil Voltage

Ordering Information When ordering, specify the Part No. and coil voltage code: (example)

0 0 0 0 0 0 0 PC Board Terminal RY2V-UL RY2V-UL RY4V-UL RY4V-UL RY2V-UD RY2V-UD RM2V-U RM2V-UL — RY4V-U — RY2V-U RY2V-U — Part Number

0

0

0 0 0 0

0 0 0 0 0 0 0 0 0 0 0 0 0 0 USA & Canada • Plug-in Terminal RY2S-UT RM2S-UD RY2S-UD RY4S-U RY4S-UT RY4S-UD RY2S-U RM2S-U RM2S-UT RY4S-ULD RM2S-UC RY4S-UC RM2S-UL RY4S-UL RY2S-UC RY2S-UL RM2S-ULD RM2S-ULC RY4S-ULC RY2S-ULC Part Number Selection Number Part Relays & Sockets & Relays Miniature Relays Miniature Series RY/RM 800-262-IDEC (4332) Model Top Bracket Mounting Top With Diode (DC coil only) With Diode (DC coil only) Standard Bracket Mounting Top With Diode (DC coil only) Standard Standard Bracket Mounting Top With Indicator and Diode (DC coil only) With Check Button With Check Button With Indicator With Indicator With Check Button With Indicator With Indicator and Diode (DC coil only) With Indicator and Check Button With Indicator and Check Button With Indicator and Check Button Top mount models are designed to mount directly to a panel and do not require a socket. Top RY2 (3A), RY4 (5A), RM2 (5A) RY2 (3A), RY4 miniature relays General purpose capacity 3A or 5A contact styles and coil voltages meet a wide range of applications Wide variety of terminal barriers. All 4PDT types have arc • • • • • 4PDT 5A Key features: DPDT (Slim) 3A Contact DPDT (Wide) 5A

Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 800 RY/RM Accessories Hold DownSprings&Clips Sockets Spring Anchor Hold-Down Replacement Stop DIN RailEnd (1 meterlength) DIN Rail Aluminum Item Appearance RY2S RM2 RY4S Relays 2. 1. Order 2piecesperrelay. Not availableforPCBmountsocketSY4S-62. Appearance SY2S-05 SM2S-05 SY4S-05 Item (top latch) (side latch) Leaf Spring Leaf Spring Spring Pullover Wire Standard DIN Rail Mount 1 1

Relay RY2S RY2S RY4S RM2 RM2, RY4S RY4S RM2 RY2S SY2S-05C SM2S-05C SY4S-05C Finger-safe DIN Rail Mount DIN rail All DINrailsockets sockets Horseshoe clipforallDINrail Use with Mount Socket For DIN SFA-101 SFA-202 SY4S-51F1 SY2S-02F1 2 2 SY2S-51 SM2S-51 SY4S-51 Through PanelMount Relays &Sockets www.IDEC.com PCB MountSocket For ThroughPanel& SFA-301 SFA-302 SY4S-51F1 SY4S-51F1 BNL5 BNDN1000 Y778-011 Part No. SY2S-61 SY4S-62 SY4S-61 PCB Mount 9.1 mmwide. length is39”(1,000mm). (10.5mm) inheightand1.37(35mm)width(DINstandard).Standard Made ofdurableextrudedaluminum,theBNDN1000measures0.413 The BNDN1000isdesignedtoaccommodateDINmountsockets. spring. 2piecesincludedwitheachsocket. For useonDINrailmountsocketwhenusingpulloverwireholddown Remarks Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 801 RY/RM - 4 34g RY4 - 4PDT 2000V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute 1000V AC, 1 minute Gold-plated silver –25 to +55°C (no freezing) 50 mΩ maximum AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz) Hz), 1.2 VA (50 AC: 1.4 VA DC: 0.9W 100,000 operations (220V AC, 5A) 200,000 operations (220V AC, 3A) 24V DC, 5 mA; 5V DC, 24V DC, 5 mA; 10 mA (reference value) (4PDT, DPDT Wide) (4PDT, 2 35g 20 ms maximum 20 ms maximum USA & Canada For use under different temperature conditions, refer to Continuous Load For use under different temperature conditions, refer to Continuous Curve. The operating temperature range Current vs. Operating Temperature of relays with indicator or diode is –25 to +40°C. When the total current of 4 contacts is less than 15A, the operating tem perature range is –25 to +70°C. Standard Contact • 2000V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute 1000V AC, 1 minute RM2 - DPDT Wide RM2 - DPDT 50,000,000 operations 3. 4. Between contact and coil: Between live and dead parts: Between live and dead parts: Silver –25 to +45°C (no freezing) 30 mΩ maximum AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz) Hz), 1.2 VA (50 AC: 1.4 VA DC: 0.9W 500,000 operations (220V AC, 5A) 24V DC, 10 mA; 5V DC, 24V DC, 10 mA; 20 mA (reference value) Between contacts of the same pole: Between contacts of different poles: 100 MΩ minimum (500V DC megger) 100 MΩ minimum (500V DC 2 Relays & Sockets & Relays (DPDT Slim), 200 m/s 2 100 m/s 1800 operations/h maximum 18,000 operations/h maximum 10 to 55 Hz, amplitude 0.5 mm 10 to 55 Hz, amplitude 0.5 mm 1000 m/s 800-262-IDEC (4332) 23g RY2 - DPDT Slim 1500V AC, 1 minute 1500V AC, 1 minute 1500V AC, 1 minute 1000V AC, 1 minute Gold-plated silver –25 to +55°C (no freezing) Operating extremes: 50 mΩ maximum AC: 1.1 VA (50 Hz), 1 VA (60 Hz) Hz), 1 VA (50 AC: 1.1 VA DC: 0.8W 45 to 85% RH (no condensation) 200,000 operations (220V AC, 3A) 24V DC, 5 mA; 5V DC, 24V DC, 5 mA; 10 mA (reference value) Electrical: Mechanical: Damage limits: Operating extremes: Damage limits: 3 1 2 2 Measured using 5V DC, 1A voltage drop method Measured at the rated voltage (at 20°C), excluding contact bouncing Release time of relays with diode: 40 ms maximum Contact Model Note: Above values are initial values. 1. 2. Contact Material Release Time Release Time Power Consumption (approx.) Weight (approx.) Weight Operating Humidity Contact Resistance Contact Resistance Mechanical Life Electrical Life Minimum Applicable Load Insulation Resistance Dielectric Strength Operating Temperature Operating Temperature Operating Time Operating Time Operating Frequency Vibration Resistance Shock Resistance

Specifications Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 802 RY/RM TÜV Ratings Contact Ratings DC CoilRatings AC CoilRatings DPDT Wide 240V AC Voltage 4PDT (RY4) DPDT Slim 30V DC Voltage (V) Voltage (V) Contact 110-120 220-240 (RM2) 100-110 (RY2) 110 220 120 240 110 24 12 48 24 12 AC: cosø=1.0,DC:L/R0ms Note: Inductiveloadfortherated—cosø=0.3,L/R7ms 6 6 DPDT Slim 3A 3A Continuous Current DPDT DPDT Slim Slim 170 9.6 4.7 8.6 4.9 — 5A 5A 3A — 42 86 128 — 18 32 64 8 DPDT Wide Rated Current(mA) 5A 5A AC 50Hz DPDT Wide& ±15% at20°C Rated Current(mA)±15%at20°C Resistive Load 1200 VA AC 1100VA AC 9.4-10.8 660 VA AC Allowable ContactPower 4.7-5.4 150W DC 150W DC DPDT Wide&4PDT 4PDT 90W DC 60.5 121 240 — — — — 4PDT Maximum ContactCapacity 5A 5A 8.2-9.0 18.5 36.9 150 — 75 Inductive Load DPDT 288 VA AC 176 VA AC Slim 440VA AC 150 8.4 4.1 7.5 4.3 — — 60W DC 75W DC 45W DC 37 75 AC 60Hz DPDT Slim 13,800 DPDT Wide& 2,660 750 188 — 47 8.0-9.2 4.0-4.6 Voltage (V) 4PDT Coil Resistance(Ω) 220V AC 220V AC 240V AC 110V AC 110V AC 100 200 30V DC 30V DC 30V DC — — — — 50 ±10%at20°C DPDT Wide&4PDT Rated Load Res. Load Relays &Sockets www.IDEC.com Coil Resistance(Ω)±10% 12,250 25,892 26,710 DPDT 2,600 6,950 8,100 Slim 76.8 18.8 650 160 300 5A 5A 5A 5A 3A 3A 3A 5A — — — 40 at 20°C DPDT Wide& Ind. Load 1.2A 2.5A 1.5A 0.8A 1.5A 2.5A 18,820 4PDT 2A 2A 4,290 39.3 153 9.4 — — — — Max. Continuous Applied Voltage 110% Max. Continuous UL Ratings CSA Ratings (against ratedvaluesat20ºC) Applied Voltage 240V AC 120V AC 100V DC Voltage Operation Characteristics 100V DC 120V AC 240V AC Voltage 30V DC 30V DC 110% (against ratedvaluesat20ºC) Operation Characteristics 80% maximum DPDT Slim DPDT 0.2A Voltage Slim 3A 3A — 3A Pickup 3A — 3A Resistive Resistive 80% maximum DPDT Wide DPDT Wide 0.4A 5A 5A — 5A 5A — 5A Voltage Pickup 10% minimum 4PDT 4PDT 0.2A 5A — — 5A Dropout 5A — 5A Voltage minimum Dropout Voltage DPDT DPDT 0.8A 1.5A 0.2A 1.5A Slim 0.2A 1.5A 0.8A Slim 3A 30% General use General use DPDT Wide DPDT Wide 2.5A 0.4A 2.5A 2.5A 2A — — 2A 4PDT 4PDT 0.2A 1.5A 0.2A 5A — 5A — 5A Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 803 RY/RM Torque 5.5 - 9 in•lbs 5.5 - 9 in•lbs 5.5 - 9 in•lbs 5.5 - 9 in•lbs 5.5 - 9 in•lbs 5.5 - 9 in•lbs — — — — — — Wire Size to 2–#14AWG Maximum up to 2–#14AWG Maximum up to 2–#14AWG Maximum up to 2–#14AWG Maximum up Maximum up to 2–#14AWG Maximum up to 2–#14AWG — — — — — — 300V, 10A 300V, 7A* 300V, 10A 300V, 7A* 300V, 10A 250V, 7A* 250V, 7A 300V, 7A 250V, Electrical Rating 7A 300V, 7A 300V, 7A 250V, 7A 300V, USA & Canada • Relays & Sockets & Relays 800-262-IDEC (4332) M3 screw with captive wire clamp M3 screw with captive wire clamp M3 screw with clamp, fingersafe M3 screw with captive wire clamp, fingersafe M3 screw with captive wire Solder Solder PCB Mount PCB Mount PCB Mount Terminal captive wire clamp M3 screws with captive wire clamp, fingersafe M3 screws with Solder SM2S-05 SY4S-05 SM2S-05C SY4S-05C SM2S-51 SY4S-51 SY4S-61 SY4S-62 SY2S-61 SY2S-05 SY2S-05C SY2S-51 Sockets * When using only 2 poles of the 4-poles, the UL recognized current is 10A. * When using only 2 poles of the DIN Rail Mount Sockets Finger-safe DIN Rail Mount Through Panel Mount Socket PCB Mount Socket Socket Specifications Socket

Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 804 RY/RM DC Load AC Load Electrical LifeCurves (RM2) (RM2) (RY2) (RY2)

Life (¥ 10,000 operations) Life ( ¥ 10,000 operations) Life (¥ 10,000 operations) 1000 Life (¥ 10,000 operations) 1000 100 200 500 100 200 500 1000 50 10 20 50 10 20 1000 100 500 100 500 50 10 0 0 50 10 0 0 1 1 100V DCresistive 100V DCinductive 30V DCinductive 30V DCresistive 110V ACresistive 220VACresistive 30V DCinductive Load Current(A) 30V DCresistive Load Current(A) 100V DCinductive 2 100V DCresistive 5 1 110V ACresistive Load Current(A) 2 220V ACinductive Load Current(A) 220V ACresistive 3 3 220V ACinductive 110V ACinductive 110V ACinductive 4 2 2 4 5 5 3 3 Characteristics (Reference Data) Relays &Sockets www.IDEC.com ` (RY4) (RY4)

Life (¥ 10,000 operations) Life ( ¥ 10,000 operations) 1000 1000 500 100 200 100 200 500 10 20 50 20 50 10 0 0 1 1 Load Current(A) Load Current(A) 240V ACresistive 30V DCresistive 2 2 30V DCinductive 240V ACinductive 3 3 4 4 5 5 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 805 RY/RM 5 4 DC Coil 3 AC Coil 2 300 Load Current (A) 200 1 AC inductive AC resistive 100 0

90 80 70 60 50 40 30 20 10

100 50 Operating Temperature (C) Temperature Operating 30 20 DC inductive DC resistive (RM2) Load Voltage (V) 10 1

5 3 2 1

0.5 0.3 0.2 Load Current (A) Current Load 3 (RY4) DC Coil 2 Load Current (A) 1 AC Coil USA & Canada 0

• 90 80 70 60 50 40 30 20 10

100 Operating Temperature (C) Temperature Operating 300 (RY4) 200 Relays & Sockets & Relays DC resistive 300 100 AC resistive 200 AC inductive 50 DC resistive 100 AC resistive 800-262-IDEC (4332) AC inductive 50 DC inductive 3 Load Voltage (V) 10 DC Coil Load Voltage (V) DC inductive 10 2 5 5 AC Coil Load Current (A) 1 1 0 1 1 5 90 80 70 60 50 40 30 20 10

5 3 1

100

0.1 0.5 0.1 0.5

Load Current (A) Current Load Load Current (A) Current Load Operating Temperature (C) Temperature Operating (RY2) (RM2) (RY2) Mounting Type) Bracket Top With Check Button, and Curve (Standard Type, Temperature Continuous Load Current vs. Operating Maximum Switching Capacity Switching Maximum Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 806 RY/RM With IndicatorandDiode(-LDtype) With Diode(-Dtype) With Indicator(-Ltype) Standard Type Internal Connection(ViewfromBottom) 24V DC Below Coil and over AC/DC 100V Coil AC/DC 100V Below Coil DPDT Slim(RY2) DPDT Slim(RY2) DPDT Wide(RM2) DPDT Slim(RY2) and over AC/DC Coil 24V DC 24V AC/ Below Coil 4PDT (RY4) DPDT Wide(RM2) DPDT Wide(RM2) DPDT Wide(RM2) over DC and Coil 24V Relays &Sockets www.IDEC.com DPDT Wide(RM2) 13(–) 9 5 1 4PDT (RY4) 4PDT (RY4) (+)14 12 8 4 4PDT (RY4) 13(–) 5 1 9 4PDT (RY4) • time isslightlylonger. ated whenthecoilisde-energized.Therelease Contains adiodetoabsorbthebackemfgener check button. Contacts canbeoperatedbypressingthe With CheckButton 10 6 2 Forward current:1A Reverse withstandvoltage:1,000V Diode Characteristics 11 7 3 (+)14 12 8 4 Pushbutton Front • • the indicatorgoeson. When therelayisenergized, LED willnotlight. If coilpolarityisreversed DC. relays forcoilsbelow100V is notcontainedinDPDT An LEDprotectiondiode absorber. indicator andasurge Contains anLED - Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers

807

27.5 4.1 12.7 6.4 RY/RM 4 8 12 14 9 8-ø1 hole 1 5 13 max.

)

13.2

27.5

41.6 6.3

(

13.2 4.1 6.4

4 8 7.15 12 14 2.6 0.5 6.4

21 27.5 9 1 5 13 Dimensions in the ( ) Dimensions in the spring. include a hold-down

4 8 12 14

0.5 2.6

21 max., SM2S-51: 39.6 max., SM2S-51: 39.6 6.4 ) 0.8 2 9 1 5 13 35.6 max. 2.2 ¥ ø1.2 hole

63.5

(

2.6 0.5 4 35.6 max. 21.5 2.2 × ø1.2 hole SM2S-05: 61.5 Total length from the panel surface including relay socket. Total length from the 0.5

3.5

35.6 max. 38 43.2

RM2S-UT RM2S RM2V

4.1 12.7

27.5 6.4

4 8 4.4 12 14 27.5 3 7 11 2 6 10 ) 9 1 5 13 6.6 4.4 4 8 12 14 max. )

3 7 11

6.3 21 4.4

6 41.6

10

(

4.4 4.4 4.1

4.4 6.4

9 7.15 12 5 13

2.6

0.5 6.4 27.5

14-ø1 holes Dimensions in the ( Dimensions in the include a hold-down spring. include a hold-down

0.5 2.6 4 8 12 14 3 7 11 21 6 2 10

2

35.6 max. max., SY4S-51: 39.6 max., SY4S-51: 39.6 9 0.8 1 5 13 hole ) 6.4

63.5

0.5 2.2 ¥ ø1.2 oblong hole (

USA & Canada oblong 2.6 • 4 Dimensions (mm) Dimensions 35.6 max. 2.2 × ø1.2 21.5 0.5 SY4S-05: 61.5 Total length from the panel surface including relay socket Total length from the

3.5

Relays & Sockets & Relays 35.6 max. 38 43.2

RY4S-UT RY4S RY4V

4.1 12.7 27.5 6.4

4 8 12 14 27.5 1 5 9 13 800-262-IDEC (4332) ) max. ) 4 8 8-ø1 holes 12 14

14

1 5 9

13

41.6

4.4 4.1 6.3 4.4 6.4 ( 7.15

2.6

0.5 5.4

27.5 2.6

Dimensions in the ( Dimensions in the spring. include a hold-down 0.5 4 8 12 14 5.4 14 1 5 9 13

35.6 max. max., SY2S-51: 39.6 max., SY2S-51: 39.6 2

) 2.6 63.5

(

3 ¥ ø1.2 oblong hole 0.5 0.8 4 3 × ø1.2 oblong hole 35.6 max. 14.5 0.5 SY2S-05: 61.5 Total length from panel surface including relay socket Total length from panel

3.5

35.6 max.

38 RY2S-UT 43.2 RY2V RY2S Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 808 RY/RM Finger-safe DINRailMountSockets StandardDINRailMountSockets

SY4S-05C 1.6 64 SY2S-05C 3 62 0.7 SY4S-05 SY2S-05 1.6 64 2 62 17.2 20 16 6 30 26 20 16 17 6 26 30 ø Screw M3 Terminal 6 4.2 5

6 4.2 4.2 Screw M3 Terminal Screw M3 Terminal

ø Screw M3 Terminal 4.2 5.5 2 46

45 45 35.5 29 25

2 18.2 46 31.5 25 18.5 18 25 31.5 14.5 18 (BNDN) DIN Rail 35.5 29 25 18.2 18 (BNDN) DIN Rail (BNDN) DIN Rail cannot beused. Ring terminals 4 max. 5.9 max. (BNDN) DIN Rail 4 max. 5.9 max. 16 16 cannot beused. Ring terminals (or M4TappedHoles) 2-ø4.2 MountingHoles 2-ø4.2 MountingHoles (or M4TappedHoles) (or M4TappedHoles) 2-ø4.2 MountingHoles 26 26 2-ø4.2 MountingHoles (or M4TappedHoles) 4.8 min. ø3.2 min. 4.8 min. ø3.2 min. Terminal Arrangement Terminal Arrangement Terminal Arrangement Terminal Arrangement ( ( Top View ( Top View 12 14 4 8 Top View 12 14 4 8 11 12 14 3 7 4 8 12 14 4 ( 8 Dimensions 13 10 Top View 1 9 5 2 6 Relays &Sockets www.IDEC.com 13 1 9 5 11 7 3 13 1 5 9 ) 10 ) 6 2 ) 13 1 5 9 ) SM2S-05C SM2S-05 1.6 64 3 62 0.7 26 30 30 26 6 6

ø

5.

4.2 Screw M3 Terminal 4.2 M3 Screw 5 T erminal

2 46 45 35.5 29 25 31.5 25 18.2 18.5 18 18 (BNDN) DIN Rail (BNDN) DIN Rail cannot beused. Ring terminals 4 max. 5.9 max. 2-ø4.2 MountingHoles 26 (or M4TappedHoles) (or M4TappedHoles) 2-ø4.2 MountingHoles 26 4.8 min. ø3.2 min. Terminal Arrangement Terminal Arrangement ( 12 14 Top View ( 4 8 12 14 Top View 4 8 13 1 5 9 13 1 5 9 ) ) Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers

809 9 RY/RM 13.8 min. ø2 holes (Tolerance 0.1) 15- 4.4 0.5 0 + 13.2

N: No. of sockets mounted

8.8 1.4

4.1

[27 (N–1) + 21.4] 10.4

16.8 14.2 min.* min.* 14.2

25.6 0

5.4 min.* 5.4 +0.2 * 10.4 min. when using hold-down springs 4 2 8 4 1 1 1 7 3 2 4 1 8 4 1 1 0 2 6 1 3 5 9 1 1 * 19.2 min. when using hold-down springs 3 5 9 1 (Bottom View) 1 (Bottom View)

Terminal Arrangement Terminal Arrangement

25.4

25.4

0.3 0.3 15 3 Panel Thickness: 1 to 2 11 3 18.7 11 1.5 2.4 27 21.2

27

21.2

31

31

SM2S-51 SY4S-61

9 9 USA & Canada • ø2 holes 15-ø2 holes 8- (Tolerance 0.1) 8.2 min.** 0.5 0 (Tolerance 0.1) + 0 0.5 + 13.6 min. N: No. of sockets mounted +12.4]

13.2

8.8

Relays & Sockets & Relays N: No. of sockets mounted

(N–1)

[18 4.1

4.4 4.1 1.4

4.4

10.4

[27 (N–1) + 21.4] 10.4

16.8 12.2 min.* 12.2

25.6 min.* 5.4 0

16.8

14.2 min.* 14.2

0.2 +

* 10.4 min. when husing hold-down springs

25.6

5.4 min.* 5.4 0

0.2 + 17.2 min. when using a hold-down spring. 13.2 min. when using a hold-down spring for the relay with check button * * 10.4 min. when using hold-down springs * * 800-262-IDEC (4332) 4 2 2 4 8 4 8 4 1 1 1 1 4 2 8 4 1 1 4 1 1 2 8 7 3 7 3 4 1 1 1 1 * 19.2 min. when using hold-down springs 3 9 1 5 1 0 2 6 0 2 6 1 3 1 9 1 5 1 3 9 1 5 3 1 5 (Bottom View) 9 1 1 (Bottom View) (Bottom View) (Bottom View) Terminal Arrangement

Terminal Arrangement Terminal Arrangement

Terminal Arrangement

25.4

0.3 25.4

25.4

0.3 0.3 0.3 15 11 Panel Thickness: 1 to 2 Panel Thickness: 1 to 2 15 3 18.7 3 11 11 3 18.7 3 11 2.4 1.5 2.4 1.5 18 21.2 12.2 27

18

21.2 12.2

31 29

31 31 SY4S-62 SY2S-61 SY4S-51 SY2S-51

PCB Mount Sockets Through Panel Mount Socket Mount Socket Panel Through Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 810 RF1V Sockets

Contact Key features: CSA C22.2No.14 UL508 EN61810-1 EN50205 Applicable Standard 4-pole 6-pole • • • • • • • Finger-safe DINrailmountsocketandPCboardsocket. High shockresistance(200m/s Fast responsetime(8msmaximum). Built-in LEDindicatoravailable. 6-pole (4NO-2NC,5NO-1NC,3NO-3NC) 4-pole (2NO-2NC,3NO-1NC) Contact configuration (EN50205 Type ATÜVapproved) Force guidedcontactmechanism Compact andENcompliantRF1Vforceguidedrelays Style 3NO-1NC 2NO-2NC 3NO-3NC 5NO-1NC 4NO-2NC Mount Sockets PC Board Mount Sockets DIN Rail Without LEDIndicator RF1V-3A1B-D48 RF1V-3A1B-D24 RF1V-3A1B-D12 RF1V-2A2B-D48 RF1V-2A2B-D24 RF1V-2A2B-D12 RF1V-3A3B-D48 RF1V-3A3B-D24 RF1V-3A3B-D12 RF1V-5A1B-D48 RF1V-5A1B-D24 RF1V-5A1B-D12 RF1V-4A2B-D48 RF1V-4A2B-D24 RF1V-4A2B-D12 No. ofPoles 2 minimum) Marking 6 4 6 4 RF1V Force GuidedRelays/SF1V Relay Sockets

Part Number Ordering Type No. SF1V-6-07L SF1V-4-07L SF1V-6-61 SF1V-4-61 With LEDIndicator RF1V-3A1BL-D48 RF1V-3A1BL-D24 RF1V-3A1BL-D12 RF1V-2A2BL-D48 RF1V-2A2BL-D24 RF1V-2A2BL-D12 RF1V-3A3BL-D48 RF1V-3A3BL-D24 RF1V-3A3BL-D12 RF1V-5A1BL-D48 RF1V-5A1BL-D24 RF1V-5A1BL-D12 RF1V-4A2BL-D48 RF1V-4A2BL-D24 RF1V-4A2BL-D12 Part NumberSelection TÜV SÜD UL/c-UL FileNo.E55996 Certification Organization/ File Number Relays &Sockets www.IDEC.com Certification forSockets CSA C22.2No.14 UL508 EN147100 EN147000 Applicable Standard Rated CoilVoltage 48V DC 24V DC 12V DC 48V DC 24V DC 12V DC 48V DC 24V DC 12V DC 48V DC 24V DC 12V DC 48V DC 24V DC 12V DC Marking

(DIN railmountsocketsonly) EC LowVoltage Directive TÜV SÜD UL/c-UL FileNo.E62437 Certification Organization/ File Number Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 811 RF1V Power Consumption Approx. 0.36W Approx. 0.5W 2 Applied Voltage Applied Voltage Maximum Continuous Maximum Continuous 110% (at 20°C) Dropout Voltage 10% minimum Operating Characteristics Remarks 35 mm Length: 1m Width: — Pickup Voltage Pickup Voltage 75% maximum USA & Canada • Type No. Type BNL5 BNDN1000 BNL6 Coil Relays & Sockets & Relays Resistance (Ω) ±10% (at 20°C) 1600 6400 400 1600 6400 288 1152 4608 288 1152 4608 288 1152 4608 400 1 Approx. 15g 800-262-IDEC (4332) Specifications (at 20°C) (mA) ±10% Rated Current Rated Current Metal (zinc plated steel) Weight: Aluminum Approx. 250g Weight: 30 41.7 41.7 41.7 15 7.5 15 7.5 20.8 10.4 20.8 10.4 20.8 10.4 30 Rated Coil Voltage (V) Voltage 12V DC 12V DC 12V DC 12V DC 48V DC 24V DC 48V DC 48V DC 24V DC 48V DC 24V DC 48V DC 24V DC 24V DC 12V DC Appearance 3NO-1NC 4NO-2NC 5NO-1NC 3NO-3NC 2NO-2NC For relays with LED indicator, the rated current increases by approx. 2 mA. For relays with LED indicator, that can be applied to relay coils. Maximum continuous applied voltage is the maximum voltage Contact 1. 2. Item 6-pole 4-pole DIN Rail End Clip Accessories Coil Ratings Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 812 RF1V Specifications Response Time (at20°C) Operating Time (at20°C) Contact Resistance(initialvalue) Minimum ApplicableLoad Allowable SwitchingCurrent Allowable SwitchingVoltage Allowable SwitchingPower(resistiveload) Rated Load(resistiveload) Weight (approx.) Operating Frequency(ratedload) Storage Temperature Operating Humidity Resistance Shock Resistance Vibration Release Time (at20°C) Strength Dielectric Insulation Resistance Power Consumption(approx.) Contact Material Operating Temperature Mechanical Life Electrical Life Contact Configuration Number ofPoles 2. 1. Failure ratelevelP(referencevalue) Measured using6VDC,1Avoltagedropmethod. Between contactsofthesamepole Operating Extremes(halfsine-wavepulse:11ms) Damage Limits Operating Extremes Between contactsofdifferentpoles Between contactandcoil Damage Limits(halfsine-wavepulse:6ms) 4 3 2 1 4. 3. When usingat70to85°C,reducetheswitchingcurrentby0.1A/°C. Response timeistheuntilNOcontactopens,aftercoilvoltageturnedoff. 20 msmaximum(attheratedcoilvoltage,excludingcontactbouncetime) 1500V AC,1minute 6A 250V AC,30VDC 1500 VA, 180W 6A 250VAC,30VDC 20g 1200 operationsperhour –40 to+85°C 5 to85%RH(nocondensation) 200 m/s 10 to55Hz,amplitude0.75mm 10 to55Hz,amplitude0.75mm 20 msmaximum(attheratedcoilvoltage,excludingcontactbouncetime) Between contacts5-6and9-10 Between contacts3-4and7-8 Between contacts3-4and5-6 4000V AC,1min. Between contacts7-8and9-10 2500V AC,1minute 4000V AC,1minute 1000 MΩminimum(500VDCmegger, samemeasurementpositionsasthedielectricstrength) 0.36W AgSnO –40 to+85°C(nofreezing) 8 msmaximum(attheratedcoilvoltage,excludingcontactbouncetime) 5V DC,1mA(referencevalue) 100 mΩmaximum 1000 m/s 10 millionoperationsminimum(operatingfrequency10,800perhour) [DC 13]24VDC1Ainductiveload:100,000operationsminimum(operatingfrequency1200perhour, L/R=48ms) [AC 15]240VAC2Ainductiveload:100,000operationsminimum(operatingfrequency1200perhour, cosø=0.3) 30V DC1Aresistiveload:500,000operationsminimum(operatingfrequency1800perhour) 250V AC1Aresistiveload:500,000operationsminimum(operatingfrequency1800perhour) 30V DC6Aresistiveload:100,000operationsminimum(operatingfrequency1200perhour) 250V AC6Aresistiveload:100,000operationsminimum(operatingfrequency1200perhour) 2NO-2NC 4-pole 2 (Auflashed) 2 , whenmountedonDINrailmountsocket:150m/s 2 Relays &Sockets www.IDEC.com 3NO-1NC 23g Between contacts7-8and9-10 Between contacts5-6and9-10 Between contacts3-4and7-8 Between contacts3-4and5-6 4000V AC,1min. Between contacts11-12and13-14 Between contacts9-10and13-14 Between contacts7-8and11-12 2500V AC,1minute 0.5W 4NO-2NC 6-pole 2

5NO-1NC 3NO-3NC Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 813 - RF1V 0 78 91 34 56 1 2 6.5 min.

+ –

3.0 min. 3.0 6.3 max. 6.3 4.0 max. Note: Ring tongue terminals cannot be used. Note: Ring tongue terminals cannot If the NO contact (7-8 or 9-10) welds, the NC contact (3-4 or 5-6) If the NO contact (7-8 or 9-10) welds, the NC contact (3-4 maintain remains open even when the relay coil is de-energized, (9-10 or ing a gap of 0.5 mm. The remaining unwelded NO contact 7-8) is either open or closed. or 9-10) If the NC contact (3-4 or 5-6) welds, the NO contact (7-8 a remains open even when the relay coil is energized, maintaining or 3-4) is gap of 0.5 mm. The remaining unwelded NC contact (5-6 either open or closed. Example: RF1V-2A2B-D24 • • Notes on Contact Gaps except Welded Contacts Notes on Contact Gaps except Welded Applicable Crimping Terminals Specifications Terminals Crimping Applicable 10 SF1V-6-61 10g — — — — — Load Current (A) USA & Canada 30V DC Resistive Load 250V AC Resistive Load • 0.11 SF1V-4-61 9g Relays & Sockets & Relays 1

10

500 100 ) operations 10,000 ( Life × Electrical Life Curve 800-262-IDEC (4332) SF1V-6-07L 55g (18 AWG to 14 AWG) (18 AWG 2 10 to 55 Hz, amplitude 0.75 mm 10 to 55 Hz, amplitude 0.75 2 250 AC Resistive Load 100 –40 to +85°C (no freezing) 5 to 85% RH (no condensation) –40 to +85°C screw terminals) IP20 (finger-safe SF1V-4-07L 6A 250V AC/DC 1000 MΩ minimum between terminals) (500V DC megger, terminals) 2500V AC, 1 minute (between M3 slotted Phillips screw 0.5 to 0.8 N·m 40g 0.7 to 1.65 mm Wire tensile strength: 50N min. Wire tensile strength: 50N Damage limits: 10 to 55 Hz, amplitude 0.75 mm Damage limits: 10 to 55 Hz, Resonance: 1000 m/s

1 Load Voltage (V) 10 DC Resistive Load When using at 70 to 85°C, reduce the switching current by 0.1A/°C. 1

6 1

0.1 10 (A) Current Load 1. Operating Humidity Storage Humidity Degree of Protection Operating Temperature Operating Temperature Part Number Rated Current Rated Voltage Insulation Resistance Dielectric Strength Style Screw Terminal Recommended Screw Torque Tightening Weight (approx.) Weight Applicable Wire Terminal Strength Terminal Vibration Resistance Shock Resistance Characteristics Maximum Switching Capacity Socket Specifications Socket Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 814 RF1V With LEDIndicator Without LEDIndicator RF1V (4-pole) With IndicatorandDiode(-LDtype) Internal Connection(ViewfromBottom) RF1V (4-pole) – – + + – – + + 2 2 2 2 1 1 1 1 3.5 24 max. 2NO-2NC Contact 2NO-2NC Contact 2NO-2NC Contact 2NO-2NC Contact 13 max. 10.16 – – + + – – + + 1.0 2 2 2 2 1 1 1 1 56 56 56 56 3 3 34 34 2NO-2NC Contact 2NO-2NC Contact 2NO-2NC Contact 2NO-2NC Contact 4 4 56 56 56 56 3 3 34 34 91 91 91 91 7 7 7 7 4 4 8 8 8 8 0 0 0 0 91 91 91 91 7 7 7 7 1.83 13.97 5.08 8 8 8 8 0 0 0 0 – – + + – – + + 40 max. 2 1 2 1 2 1 2 1 3NO-1NC Contac 3NO-1NC Contac 3NO1NC Contac 3NO1NC Contac – – + + – – + + 2 1 2 1 1 2 1 2 56 34 56 3 56 3 56 34 3NO-1NC Contac 3NO-1NC Contac 3NO1NC Contac 3NO1NC Contac 4 4 11 5.08 .43 0.5 56 3 56 34 56 3 56 34 91 78 91 7 91 7 91 78 4 4 t t 8 8 t t 0 0 0 0 RF1V (6-pole) 91 78 91 7 91 7 91 78 t t 8 8 t t 0 0 0 0 3.5 24 max. 13 max. 10.16 RF1V Dimensions(mm) 1.0 With LEDIndicator Without LEDIndicator RF1V (6-pole) – – + + – – + – + – + – + – – + – + + – + – + + 2 2 1 1 2 2 1 1 2 2 1 1 2 2 2 2 1 1 1 1 2 2 1 1 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac 4NO-2NC Contac Relays &Sockets www.IDEC.com 56 56 34 34 56 56 34 34 56 56 34 34 56 56 56 56 34 34 34 34 56 56 34 34 5.08 13.97 1.83 91 91 7 78 91 91 78 7 91 91 7 78 91 91 91 91 78 7 78 7 91 91 7 78 81 81 81 81 01 01 81 81 01 01 01 01 01 01 01 01 01 01 50 max. 11 11 11 11 11 11 t3 t3 t3 t3 t3 11 31 31 t3 t3 t3 t3 11 31 31 t3 11 31 31 t3 11 31 31 t3 11 31 31 11 31 31 12 12 12 12 12 12 2 4 4 2 4 4 2 4 4 2 4 4 2 4 4 2 4 4 11 .43 5.08 – + + – – + + – – + + – – – + + + + – – – + + – 5.08 5.08 0.5 2 2 1 1 2 2 1 1 2 2 1 1 2 2 2 2 1 1 1 1 2 2 1 1 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 5NO-1NC Contac 56 56 34 34 56 56 34 34 56 56 34 34 56 56 56 56 34 34 34 34 56 56 34 34 Layout (BottomView) PC BoardTerminal typeMountingHole RF1V (6-pole) RF1V (4-pole) 10.16 ±0.1 ±0.1

(1.83) 10.16 13.97 (1.83) 13.97 91 91 7 78 91 91 7 78 91 91 7 78 91 91 91 91 7 78 7 78 91 91 78 7 ±0.1 81 81 81 81 01 01 81 81 01 01 01 01 01 01 01 01 01 01 ±0.1 5.08 11 11 11 11 11 11 t t t t t 11 3 31 t 11 t 3 31 11 31 3 t 11 3 31 11 31 3 t 11 31 3 t t t 5.08 12 14 ±0.1 12 14 12 14 12 14 12 14 12 14 2 4 2 4 2 4 2 4 2 4 2 4 – + – – + + – + – – – + + – + – + – + – + + – + 2 2 1 1 2 2 1 1 2 2 1 1 2 2 2 2 1 1 1 1 2 2 1 1 11

11 10- 1.4 hole 5.08 NO-3NC Contact NO-3NC Contact NO-3NC Contact .43 NO-3NC Contact NO-3NC Contact .43 NO-3NC Contact NO-3NC Contact NO-3NC Contact NO-3NC Contact 5.08 NO-3NC Contact NO-3NC Contact NO-3NC Contact 56 56 34 34 56 56 34 34 56 56 34 34 56 56 56 56 34 34 34 34 56 56 34 34 ±0.1 ±0.1 ±0.1 5.08 14- 1.4 hole ±0.1 5.08 ±0.1 ±0.1 91 91 78 7 91 91 78 7 91 91 78 7 91 91 91 91 78 7 78 7 91 91 7 78 81 81 81 01 81 01 81 81 01 01 01 01 01 01 01 01 01 01 11 11 11 11 11 11 11 31 31 11 31 31 11 31 31 11 31 31 11 31 31 11 31 31 12 12 12 12 12 12 2 4 4 2 4 4 2 4 4 2 4 4 2 4 4 2 4 4 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 815

RF1V

75 5 6. 5 6. 29.8

4 R2 5 6.3

2–M3.5 or ø4 holes 3 5. 4 ø6.2 M3 Terminal Screw (Top View) (Top ±0.2 80.0 3 7 4 8 11 12 35.4 1 (Panel Mounting Hole Layout) 2 5 9 (Top View) (Top 6 13 10 14

(Internal Connection)

22

±0.2

58.9 62.4 USA & Canada

• SF1V-6-07L (6-pole) SF1V-6-07L

75 56 6. .5 Relays & Sockets & Relays 4 22.4

R2

5

3 6.3 5.

800-262-IDEC (4332) 4 2–M3.5 or ø4 holes SF1V DIN Rail Mount Socket Dimensions (mm) Dimensions Socket Mount DIN Rail SF1V

ø6.2 M3 Terminal Screw (Top View) (Top ±0.2

4

5.

3 80.0 (Panel Mounting Hole Layout) 8 1 2 7 9 5 3 4 6 10 (Top View) (Top

(Internal Connection)

5 14. 58.9

±0.2 62.4 SF1V-4-07L (4-pole) SF1V-4-07L Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 816 RF1V SF1V-4-07L (4-pole) 10.16 ±0.1 3-ø3.2 holesforM3self-tappingscrews 6.93 (13) (6.93) 4.1 ±0.1 13.97 13.97 5.08 5.08 ±0.1 50 max. ±0.1 24.8 39.9 ±0.1 6.2 11.43 ±0.1 5.08 0.4 (13)

11.43 15 max. 5.08 ±0.1 10- ø1.1 hole 40 max. ±0.1 10.16

0.8 3.5 1 2 5 3 0.6 3.6 SF1V PCBoard MountSockets 6 4 9 7 10 8 Relays &Sockets www.IDEC.com SF1V-6-07L (6-pole)

10.16 ±0.1 3-ø3.2 holesforM3self-tappingscrews 6.93 (6.93) (13) 4.1 13.97 ±0.1 13.97 5.08 ±0.1 5.08 60 max. ±0.1 24.8 6.2 ±0.1 49.9 11 .43 5.08 5.08 ±0.1 5.08 0.4 11 (13) .43

5.08 15 max. 5.08 ±0.1 ±0.1

±0.1 40 max. 14-ø1.1 hole 5.08 10.16 0.8 3.5 1 2 5 3 0.6 3.6 6 4 9 7 10 8 13 11 12 14 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 817 Operating Instructions Operating of approximately the same resistance 0.1 to 1 µF R: Resistor of approximately the same resistance value as the load C:0.1 to 1 µF This protection circuit can be used for DC load power circuits. Use a diode with the following ratings. Reverse withstand voltage: Power voltage of the load circuit x 10 Forward current: More than the load current This protection circuit can be used for both AC and DC load power circuits. For a best result, when using a power voltage of 24 to 48V AC/DC, connect a across the load. When using a power voltage of 100 to 240V AC/DC, connect a varistor across the contacts. This protection circuit can be used when the load This protection circuit can be the RC impedance in an impedance is smaller than AC load power circuit. • • This protection circuit can be used for both AC and DC load power circuits. R: value as the load C: Load Load Load Ind. Ind. Ind.

This protection circuit is very effective in when This protection circuit is very effective in arc suppression the opening the contacts. But, the is charged while capacitor contacts are opened. When the contacts are closed, the is discharged through the contacts, increasing the possibility of contact welding. This protection circuit is very effective in arc suppression when opening the contacts. But, when the contacts are closed, a current causing contact welding. flows to charge the capacitor, aristor V D CR Load Load

wer wer wer

– C + Po Po Po C

Diode Varistor RC Power Power The contact ratings show maximum values. Make sure that these values are values. Make sure that ratings show maximum The contact the contact flows through the load, When an inrush current not exceeded. circuit, connect a contact protection welded. If this is the case, may become limiting resistor. such as a current Contact protection circuit: load, arcing causes carbides to form on the When switching an inductive contact resistance. In consideration of contact contacts, resulting in increased a surge absorbing circuit contact life, and noise suppression, use of reliability, the release time of the load becomes slightly is recommended. Note that of a contact operation using the actual load. Incorrect use Check the longer. affect switching characteristics. Four typical protection circuit will adversely circuits are shown in the following table: examples of contact protection When soldering the relay terminals, use a soldering iron of 30 to 60W, and When soldering the relay terminals, use a soldering iron of 30 to 60W, quickly complete soldering (within approximately 3 seconds). Use a non-corrosive rosin flux. Do not use a contact protection circuit as shown below: Do not use a contact protection circuit as shown switching a DC inductive load is more difficult than switching a DC Generally, will improve the however, resistive load. Using an appropriate arc suppressor, switching characteristics of a DC inductive load. Protection for Relay Contacts Protection 1. 2. Soldering 1. 2. 3. DC USA & Canada • 100% Pulsation Operating Instructions Operating Emin

Emean Emean Relays & Sockets & Relays Emax – Emax )¥ R Relay = Maximum of pulsating current = Minimum of pulsating current = DC mean value Emin R

actor (% – + Emax Emin Emean 800-262-IDEC (4332) Ripple F

Back emf suppressing diode Relay R

TE + – Smoothing Capacitor Io R When the relay coil is turned off, a high-voltage pulse is generated, causing a When the relay coil is turned off, a high-voltage Be sure to connect a diode transistor to deteriorate and sometimes to break. the coil release time becomes to suppress the back electromotive force. Then, release time, connect a shorten the coil To slightly longer. diode with Select a Zener between the collector and emitter of the transistor. a Zener voltage slightly higher than the power voltage. Surge suppression for transistor driving circuits: Correct Incorrect Leakage current while relay is off: relay operation, special When driving an element at the same time as the shown in the incorrect consideration is needed for the circuit design. As (Io) flows through the relay coil while the relay leakage current circuit below, or adversely affects the is off. Leakage current causes coil release failure a circuit as shown in the vibration resistance and shock resistance. Design correct example. To ensure correct relay operation, apply rated voltage to the relay coil. apply rated voltage to correct relay operation, ensure To for the DC coil: Input voltage of stable relay coil power to make sure DC voltage is best for the A complete power supply containing a ripple voltage, suppress operation. When using a When power is supplied through a rectification the ripple factor within 5%. characteristics, such as pickup voltage and dropout circuit, the relay operating for better Connect a smoothing capacitor factor. voltage, depend on the ripple as shown below. operating characteristics

4.

3.

Driving Circuit for Relays Driving Circuit 1. 2. Operating Instructions Operating Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 818 Operating Instructions • • • • 1. Other Precautions

relay topreventdamage. ing elementmaybedamaged.Addanothersurgeabsorbingprovisiontothe the relayissubjecttoanexcessiveexternalsurgevoltage,absorb provided toabsorbthebackelectromotiveforcegeneratedbycoil.When Surge absorbingelementsonACrelayswithRCorDCdiodeare en theterminalscrewsonrelaysockettopropertighteningtorque. Use wiresofthepropersizetomeetvoltageandcurrentrequirements.Tight- hazard maybecaused. Observe specificationsandratedvalues,otherwiseelectricalshockorfire cause electricalshockorfirehazard. maintenance, andinspectionoftherelays.Failuretoturnpoweroffmay Turn offthepowertorelaybeforestartinginstallation,removal,wiring, (SO Use therelayinenvironmentsfreefromcondensation,dust,sulfurdioxide maintain theinitialcharacteristics,donotremoverelaycover. The relaycovercannotberemovedfromthebaseduringnormaloperation.To To maintaintheinitialcharacteristics,donotdroporshockrelay. General notice: Make surethatthecoilvoltagedoesnotexceedapplicable range. 2 ), andhydrogensulfide(H 2 S). Operating Instructions con’t Safety Precautions Relays &Sockets www.IDEC.com - 3. 2. • • • • Precautions fortheRURelays relay operation. Do notuserelaysinthevicinityofstrongmagneticfield,asthismayaffect UL andCSAratingsmaydifferfromproductratedvaluesdeterminedbyIDEC. age tothecorrectterminals. DC relayswithadiodehavepolarityinthecoilterminals.Applyvolt ing polestopreventthepossibilityofshortcircuits. neighboring polesandanegativevoltagetotheotherterminalsofneighbor When usingDCloadson4PDTrelays,applyapositivevoltagetoterminalsof is aminimumof100operations. Do notusethelatchingleverasaswitch.Thedurabilityof nal position. the RU relay. Aftercheckingthecircuit,returnlatchinglevertoorigi Before operatingthelatchingleverofRUrelay, turnoffthepowerto - - - Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 819 RSC 400 45A 30A 0.5 1.3 IP20 4200 4000 models) 47 to 63 -20 to +80 -40 to +100 225 polycarbonate 8 AWG to 16 AWG 8 AWG 16 AWG to 24 AWG 16 AWG to 16 AWG 10 AWG Anodized aluminum black UL94-V0 Self-extinguishing 20A -20 to +60 (90-140 V AC input Model

Operating temperature (ºC) Storage temperature (ºC) Input-to-Output isolation voltage (Vrms) Input/Output to ground isolation voltage (Vrms) Operating frequency (Hz) Housing material Heat sink material Protection (IEC 60529) - Casing Input terminal tightening torque (Nm) Output terminal wire size (stranded) Output terminal wire size (solid) Output terminal tightening torque (Nm) (g) Weight Input terminal wire size (stranded and solid) General Characteristics General Specifications USA & Canada • Part Number Relays & Sockets & Relays RSCDN-20A RSCDN-30A RSCDN-45A RSCA1N-20A RSCA1N-30A RSCA1N-45A RSCA2N-20A RSCA2N-30A RSCA2N-45A* Solid State Relays State Solid Series RSC 800-262-IDEC (4332) 20A 30A 45A 20A 30A 45A 20A 30A 45A Rating Output Current UL Recognized File No. E194577 *Input control voltage is 180-260V AC. Input Control Voltage Slim design allows for DIN rail or panel mounting allows for DIN rail or panel Slim design output capability sink maximizes current Built-in heat Epoxy-free design 45A models Choice of 20A, 30A and LED indicator terminals Finger-safe Zero voltage switching Back-to-back SCR output substrate construction Direct Bond Copper (DBC) (TVS) Built-in transient protection rating 100k-cycle UL508 endurance CE Marked UL Recognized, TUV Approved, Lead free and RoHS compliant EMC (Level 3) & IEC 62314 compliant • • • • • • • • • • • • • • 4-32V DC 90-140V AC 180-280V AC Part Number Selection Part Key features:

RSC Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 820 RSC Specifications con’t Output Specifications Input Specifications Safety Standards 2. *45Amodelis180-260VAC 1. LEDisnotanabsoluteindicatorofpowerbeingpresent. Overvoltage Pollution CISPR 11 for industrialenvironmentsper Conducted andradiatednoise 1000-4-6) common modeacc.toENV(CEI Immunity toradiofrequencyin cording toIEC/EN61000-4-5 Immunity toshockwavesac- bursts toIEC1000-4-4 Immunity torapidtransient ENV 50140/204(IEC1000-4-3) Immunity toelectrostaticfields discharges IEC/EN61000-4-2 Immunity toelectrostatic Shock testIEC60068-2-27 EN60068-2-6 Vibrations accordingtoIEC/ Conformity tostandards I On-state voltagedropatImax(Vpeak) Minimum current(mA) Current max@40ºC(A) and T=25ºC(µA) Maximum off-stateleakageatVmax Non-rep. peakvoltage(Vpeak) Voltage range(Vrms max) Max. turn-offtime(ms) Turn-on time(ms) Min. inputcurrent(mA) Max. controlledcurrent(mA) Turn-off voltage(V) Input voltage(V) Max. non-rep.1-cyclesurge(T=25ºC)(A) Max. non-rep.1ssurge(T=25ºC)(A) Utilization CategoryAC-53(A) Utilization categoryAC-51(A) HP ratingsat480V HP ratingsat240V HP ratingsat120V Static (off-state)dv/dt(V/µs) 2 t (t=10ms)(A Model 2 Model Model s) (50/60Hz) Category III Degree 2 Class A Level 3 Level 3 Level 3 Level 3 Level 3 15 G/11ms 35 mm/10-55Hz UL recognizedper508 TUV certifiedperEN60950 IEC 60947-4-2(AC53a) IEC 62314 8.33 (60Hz)/10(50Hz) 8.33 (60Hz)/10(50Hz) 20A 1225/1020 4-32V DC 48-600 1100 20A 100 120 495 100 500 1/2 1.2 20 16 20 20 – 1 6 1 20A, 30A,45A 30A c-UR perC22.2.no.14-95 CE compliantwithLVD 73/23/EEC IEC 60947-4-3(AC51) 90-140V AC 2850/2350 48-600 1100 30A 100 120 750 150 500 3/4 1.2 30 30 10 30 30 Relays &Sockets www.IDEC.com – 5 6 9 2 180-280V AC* 3200/2600 45A 48-600 1100 1.35 45A 100 120 800 160 500 1.5 30 30 10 45 10 45 6 8 3 5 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 821 RSC 45A Model 20A/30A Models USA & Canada • Dimensions (mm) Dimensions Relays & Sockets & Relays 800-262-IDEC (4332)

RSS

Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 822 RSS Part NumberSelection Key features: 4-32V DC DC Input 90-280V AC AC Input • • • • • • • • • • • Optional fingersafeterminalcover(RSS-CVR) High surgecapability Zero voltageturn-on 4000 Volt opticalisolation 1200 Volt blockingvoltage Photo isolation EMC compliant(level3) Internal transientprotection–built-insnubber Direct bondcoppersubstrate Dual SCRoutput Input statusLEDIndicator Input File No.E194577 UL Recognized Output Current Continuous 90A 75A 50A 25A 10A 90A 75A 50A 25A 10A RSS Series Panel MountSolid StateRelays Part Number RSSDN-90A RSSDN-75A RSSDN-50A RSSDN-25A RSSDN-10A RSSAN-90A RSSAN-75A RSSAN-50A RSSAN-25A RSSAN-10A

Specifications Output Specifications Input Specifications Relays &Sockets www.IDEC.com Weight Commutating DV/DT Static DV/DT Zero Voltage Switching Turn-Off Time Turn-On Time Off-State LeakageatRatedVoltage Frequency Range Over Voltage Rating Output Voltage Range Voltage DropatRatedCurrent 1-Cycle SurgeCurrent Minimum HoldingCurrent 1-Second SurgeCurrent Current (continuous) Rev. Voltage Protection Capacitance (InputtoOutput) (Input-Output-Base) Dielectric Strength Drop OutVoltage Pick UpVoltage Input Current Voltage Range Series 10g (approx.) Snubbed for0.5powerfactoratratedload 200V/µsec Yes 1/2 cycle@60Hz 1/2 cycle@60Hz 20mA (maximum) 47 to80Hz 1200 PIV Dual SCR(N.O.) 48 -660VAC 1.6V (maximum) Yes (–32VDC) 8pF 4000 RMS(min) 1V DC 4V DC current regulated(10mA) 4 to32VDC 50mA 150A 30A 10A RSSDN 50mA 300A 75A 25A 100mA 750A 150A 50A N/A 8pF 4000 RMS(min) 10V AC 90V AC 90 to280VAC 100mA 1000A 225A RSSAN 75A 100mA 1200A 300A 90A Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 823 RSS USA & Canada • Recommended Loads Recommended 2KW 4KW 6KW 1KVA 2KVA 4KVA 1,800W 4,200W 7,500W at 240V AC at 240V AC at 240V AC Relays & Sockets & Relays 800-262-IDEC (4332) 1KW 2KW 3KW 1KVA 2KVA 900W 500VA 2,100W 3,800W at 120V AC at 120V AC at 120V AC 10A 25A 10A 25A 50A 50A 10A 25A 50A SSR Rating SSR Rating SSR Rating RSS series relays provide a highly reliable means of switching AC loads when applied properly. Read the technical notes on the following page prior to installing Read the technical notes on the following page prior properly. of switching AC loads when applied RSS series relays provide a highly reliable means solid state relays. Recommended Loads RSS relays use high-noise immunity circuitry with a built-in to handle the electrical noise generated by inductive loads. a built-in snubber to handle the RSS relays use high-noise immunity circuitry with Solenoid Valves and Contactors Solenoid Valves Recommended Loads Heater Loads stress will result. In such cases, use severe thermal continuously, and off rapidly and on for driving heaters where the load is switched When using solid state relays than 75% of the rating. an SSR relay at no more Recommended Loads Transformer Loads Transformer has a 1/2 rated for this surge, which first cycle. Use a relay saturates during the when the transformer in severe inrush current loads sometimes result Transformer 10x rated current). resistance (approximately primary the transformer’s maximum applied line voltage; greater than the cycle surge current Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 824 RSS Internal CircuitBlockDiagram Recommended Loads reduce inrushcurrentandprolonglamplife. Zero voltageswitchingisidealfordrivingincandescentlamps,sincethecoldfilament willnotbesubjectedtoalargeinrushcurrent.Usingzero-switchedSSR Lamp Loads UL MotorLoadRatings(HPRatings) Part Number SSR Rating 90A 75A 50A 25A 10A 50A 25A 10A 120V 3/4 3/4 3/4 1/2 1/2 at 120VAC 3KW 2KW 1KW 1 1/2 240V 3/4 3/4 5 5 at 240VAC 6KW 4KW 2KW 1 1/2 480V 3/4 3/4 5 5 Relays &Sockets www.IDEC.com Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 825 RSS USA & Canada • Technical Notes Technical Relays & Sockets & Relays Material Aluminum (black anodized) Aluminum (black anodized) Aluminum (black anodized) Aluminum (black anodized) Aluminum (black anodized) Aluminum (black anodized) Lowest Voltage 800-262-IDEC (4332) Dimensions 17” x 17” x 1/8” 17” x 17” x 1/8” 15” x 15” x 1/8” 15” x 15” x 1/8” (AC/AC) 12” x 12” x 1/8” (DC/AC) 12” x 12” x 1/8” Use #6 – 32 screws, flat washers, and lock washers to secure mounting on heat sinks. to secure mounting Use #6 – 32 screws, flat washers, and lock washers 90A 75A 50A 25A 25A 10A 0V Output Rating Over 4V Additional Information Do not exceed the load voltage and current specifications. use a resistor in parallel with the load to SSR has turned off. If this is the case, A small-capacity load may not turn off due to the leakage current present after the shunt the leakage current. SSR. Observe the polarity of input terminals. Failure to do so may cause damage to the output terminals to absorb the over-voltage. element should be connected to the When the SSR output is subjected to a higher than rated voltage, a varistor or other of 4V. exceed the minimum pick-up voltage When the input signal contains a ripple voltage, the lowest ripple amplitude should Vertical mounting is recommended to allow air to flow unimpeded. Horizontal or inverted mounting is possible, but the SSR must be derated according to the derating inverted mounting is possible, but the mounting is recommended to allow air to flow unimpeded. Horizontal or Vertical curves on the following page. Provide sufficient ventilation. Mounting Wiring current. to prevent malfunction from induced Locate SSRs as far from motor leads as possible current. exposed to a source of induced Use shielded wires for input leads when they are Using a thermal compound between the base of the SSR and the heat sink for heat dissipation is recommended. the SSR and the heat sink for heat Using a thermal compound between the base of Heat sinks are recommended for all solid state relays depending on ambient temperature and mounting position. The recommended heat sink dimensions and mate- position. The recommended heat sink dimensions and mounting temperature for all solid state relays depending on ambient Heat sinks are recommended rial are shown in the table: Heat Sinks Environment well ventilated. and applications are dry excessive heat. Make sure SSRs near sources of Do not install it the load current so that reduce collectively, or if SSRs are mounted ventilation, temperatures or poor subject to high be installed in an environment If SSRs must on the following page.) Derating Curves the Temperature (See current recommendation. ambient temperature-load does not approach the current. the peak surge half of inductive loads, suppress the inrush current to When SSRs are used with Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 826 RSS

Load Current (Amperes) Load Current (Amperes) Load Current (Amperes) 50 Ambient Ambient Ambient 90 10 AMP AMP AMP T T T SCR emperature emperature emperature SCR SCR OUTPUT OUTPUT OUTPUT (°C) (°C) (°C) Temperature DeratingCurves:RSSSeries Relays &Sockets www.IDEC.com

Load Current (Amperes) Load Current (Amperes) 75 Ambient Ambient 25 AMP AMP SCR T T emperature emperature SCR OUTPUT OUTPUT (°C) (°C) 1.5°C/ 1.0°C/ 0.7°C/ 0.5°C/ W W W W 1 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 827 RSS 0.5" (12.70mm) 0.37" (9.40mm) 1.9" (48.26mm)

0.79" (20.07mm)

2.4" (6.96mm) 2.4" 2.65" (67.31mm) 2.65" RSS-CVR - Optional Fingersafe Cover 1.075" (27.31mm) USA & Canada •

Dimensions (mm) Dimensions

0.2" (4.8mm)

ø0.187" (4.5mm) (47.6mm) 1.88" Relays & Sockets & Relays (24.1mm) 0.95" 2 3+ 800-262-IDEC (4332) 1.0" (25.4mm) 1.75" (44.5mm) 1.1" (27.9mm) -4

1

1.7" (43.2mm) 1.7" R 0.265" (6.7mm) 2.25" (57.2mm) 2.25" 0.09" (2.3mm) an Head Screw an Head Screw Small Saddle Clamp 6-32 P 8-32 P Large Saddle Clamp Large Saddle Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights 828 Relays &Sockets www.IDEC.com