ENAPTER ELECTROLYSER SYSTEMS

ENAPTER ELECTROLYSERS ARE THE PORTAL TO THE HYDROGEN ECONOMY

Our AEM electrolysers are the most cost-effective and high performance solution for hydrogen production ranging from 0.5Nm3/hr to 10Nm3/hr.

FLEXIBLE • SCALABLE • FAST TO DEPLOY

EL 2.0 Key Features • 500 NL/hr or 0.5 Nm3/hr hydrogen output • Stackable to form larger electrolyser systems • Output pressure up to 35 bar • Hydrogen purity 99.95%, 99.999% with optional dryer module

3 • High efficiency (4.8 kWh for 1 Nm of H2 at system level) • Rack-mountable in standard 19” cabinet • Native operation with Enapter EMS (remote monitoring and control system) • Simple installation and low maintenance • Low requirements for input water purity

Up to four EL 2.0 modules and one optional dryer can be combined in a single 19” cabinet by Enapter or a qualified system integration partner. Please see next page for more details on the optional modules offered by Enapter. EL 2.0 Data Sheet

Technical Data

H2 production rate 500 NL/hr Working pressure 35 Bar Water consumption 0,4 L/hr

Water specification <20 microS (at 25°C) µS/cm Water input pressure 1-2 Bar Power supply options AC 100-240 Vac, 50-60Hz

Operative power consumption 2,4 kW (at standard conditions) Peak power consumption 3,0 kW (max power draw at anytime)

Module dimensions (WxDxH) 483 x 490 x 354 mm (8U) EL 2.0 Module weight (without water) 53 Kg Ambient temperature 5–45 °C Ambient humidity 20–95%

Dryer 2.0 Dryer 2.0 19" Cabinet Integration

The optional dryer module EL 2.0 Enapter offers integration of EL 2.0 in can process up to 2Nm3/hr of a weatherproof cabinet for deployment hydrogen gas from the EL 2.0 directly on the customer site. and bring the output purity EL 2.0 to >99.999%.

EL 2.0 3 H2 flow rate Up to 2 Nm /hr (4 x EL 2.0) Operative power 375 W consumption EL 2.0 Dimension 483 x 490 x 178 mm (4U)

Enapter Water Supply System Components

Water Purification Module (WPM) Water Tank

An optional 40L clean water Input water tap / rain water tank can be integrated into the cabinet. Output water <20 µS/cm Operative power It can be filled by the WMP or 200 W (20W standby) consumption other clean water supply and includes a pumping system Typical flow rate 0.2-0.4L/min to supply the electrolysers.

Mounted on sidewall of caninet or other wall surface Size in cabinet: 8U.

Enapter’s water supply system is completely optional and our customers are welcome to use any water supply system to EL that meets the specifications (<20 µS/cm).

www.enapter.com [email protected]

Germany Thailand Rheinsberger Str. 76/77, Via di Lavoria, 56/G - 56040 33/4 Moo4, Phi Suea House, San Phi Suea, 10115 Berlin Crespina (PI) A. Muang, Chiang Mai, 50300 +49 30 25814 7916 + 39 050 7620120 + 66 2 107 1104 ENAPTER EMS MONITORING SYSTEM Enapter addresses the critical importance of understanding both your system and the environment it operates in. Made of a network of sensors and interfaces, the monitoring and control solution complements our electrolysers. It enables complete control and peace of mind, no matter where in the world you or your system are. Cloud Platform + Energy Monitoring Gateway

Time Series Database Analytic Dashboard The Enapter Cloud aggregates the data from connected devices and sites. It provides

Enapter Cloud Engine and Billing online analytics, reporting and monitoring with Machine Learning algorithms.

MQTT Broker API Gateway

HTTPS REST 3rd Party Service The Mobile Application is Integration API the interface for the end- user’s connected devices. It allows for easy system Cloud HTTPS REST setup, management and Web Client monitoring all over the world.

MQTT TLS HTTPS HTTPS REST Mobile Application Cloud/ Internet The IoT Gateway serves multiple functions: Local OPC UA TCP/IP OPC UA Server - Aggregate the connections of Communication Modules to save data locally

Wi-Fi HTTPS Gateway Web Client - Mitigate connectivity issues, and minimize amount of traffic pushed to the Cloud

Wi-Fi Bluetooth LE - Provide rule-based engine to Mobile Application control connected devices.

Wi-Fi MQTT TLS Wi-Fi MQTT TLS Wi-Fi MQTT TLS

Communication Module Communication Module Fuel Cell Enapter Electrolyser The IoT Communication Universal Module connects analog and I/O board digital sensors, and devices to the internet to allow real

CAN Bus Digital Serial etc. etc. time monitoring and control. SNMP

HYDROGEN

System 3rd party fuel cell Battery H2 Tank Solar component Valve control or sensor

[email protected] Log out Energy Management Platform

Devices [email protected] Log out

< Zoom Out > Last 5 minuites DEVICES / Edit Devices Dashboard Demo 1 Online

null

Restart with max pressure All (6) Online (3) Offline (3) Production OK Description OK Contains State Description Model Serial Num Hardware ID Production 15:17 15:18 15:19 15:20 MODEL STEADY Demo1 Enapter EL1000 000000 DEMO1 Contains

ERROR El2.0 Prototype 1 / AnalogLamb0 Enapter EL 500 13 37DAC657F SERIAL NUM System Info System Issue Contains MAX PRESSURE Simulator Enapter EL1000 000000 2001 - value Level Type Code Fiirst Appearance Last Appearance HARDWARD ID El1000 0 Error Water_level_sensor 2018-08-27 15:16:30 2018-08-27 15:19:30 ERROR TestStation 5 (EL500 Stack 2.0) / AnalogLamb3 Enapter 0 93F7634B15 - Contains

Test Board 2 Enapter 0 33991ADA92 - Demo 0 Error Press_switch 2018-08-27 15:16:30 2018-08-27 15:19:30 Fillter Clear Fillters Test Board 1 Enapter 0 7B40954E30 - 000000 1 Alarm Hight_temperature 2018-08-27 15:16:00 2018-08-27 15:20:30

Pisa office (33991ADA921521BB1C7415A0BF614AD86EBC32C9) Perform OTA Download CSV 0.1 Download: CSV XML JSON Displaying all 6 Devices

Pisa office (33991ADA921521BB1C7415A0BF614AD86EBC32C9) Perform OTA Download CSV H2 Production System Pressure

21:50 100 % 0.05 bar 21:50 100 %21:50 0.04 bar 0.04 bar 0.03 bar 21:50 21:50 21:50 0.02 bar General Charts Issues 0.01 bar 33991ADA921521BB1C7415A0BF614 General Charts Issues 0 bar Devices [email protected] Log out 15:18 15:19 15:20 15:16 15:17 15:18 15:19 15:20 21:50 100 % min max avg current min max avg current Version Electrolyser Pressure DEVICES / 05 Mar 2018 21:50 Edit Devices Dashboard 1.01L 1.06 kL 1.03 kL 1.04 kL System Pressure 30.00 bar 31.00 bar 30.49 bar 30.73 bar 33991ADA921521BB1C7415A0BF614 05 Mar 2018 21:50 Cumulative runtime Berlin Demo 1 Berlin Range: Electrolyser5 minutes EL 1000 Version Stack Pressure Outlet Pressure Status Electrolyser EL 1000 General Charts Issues H2 Production 600 L Cumulative runtime 1.06 kL Activity Steady 500 L 50 bar 600 L/hr Device Status State 1.06 kL 2018-03-09 11:36:14 Device Status State Online Production 05 Mar 2018 21:50 1.05 kL Module A Error OK H2 Production 254.46 L Online40 bar Production 500 L/hr 600 L Berlin 1.04 kL 500 L 31.0 31.6 Module A Alarm OK Electrolyser EL 1000 1.03 kL 30 barHydrogen 400 L/hr 2018-03-09 11:36:14 Hydrogen 2,000 NL/hr 11:35:00 11:35:30 11:36:00 11:36:30 11:37:30 Production Rate 2,000 NL/hr 1.01 kL H2 Production 254.46 L Production Rate 15:20 20 bar 300 L/hr Device Status State 1.00 kL System Pressure Module Issue 14:30 14:35 14:40 14:45 14:50 14:55 15:00 15:05 15:10 15:15 15:20 15:25 Current Online Production Current 35 bar Level Type Code Fiirst Appearance Last Appearance 11:35:00 11:35:30 11:36:00 11:36:30 11:37:30 10 barOutlet Pressure 35 bar 200 L/hr Outlet Pressure Hydrogen 0 Error press_switch 2018-08-27 15:16:30 2018-08-27 15:19:30 2,000 NL/hr Details Commands 0 bar 100 L/hr Production Rate 0 Error flow_switch 2018-08-27 15:16:30 2018-08-27 15:19:30 Stop electrolyser Start Stop Reboot Configure Network Save Configuration Read Network Config 09:30 09:35Stop electrolyser09:40 09:45 09:50 STATUS STEADY STATUS Current 35 bar ESP Reboot ESP OTA ESP Factory Reset 1 Alarm hight_temp 2018-08-27 15:16:00 2018-08-27 15:20:30 Outlet Pressure DESCRIPTION Demo Outlet PressureNeed help? Production Rate Need help? STATUS COMMAND EXECUTION STATE INTIATED AT 15:18 15:19 15:20 0 Error Low_Water 2018-08-27 15:16:00 2018-08-27 15:20:30 TYPE electrolyser TIME OUT EL Stop NO 2 days ago min max avg current Stop electrolyser MODEL Enapter EL1000 All Executed Commands 30.01 bar 31.00 bar 30.49 bar 30.97 bar 30.00 bar 31.99 bar 30.96 bar 31.15 bar SERIAL NUM 000000 Need help? Commands

HARDWARE ID DEMO1 Stack Part 1 Amp/Volt Stack Part 1 Amp/Volt SEVERITY DESCRIPTION APPEARED AT FW VER 0.1 35 A 11.25 V 35 A WARNING sys_alarm_high_temperature 2018-08-25 14:57:08 UTC 11.00 V EL FW VER EMPTY mod_b_alarm_high_temp 2018-08-25 14:57:08 UTC WARNING 30 A 10.75 V 30 A WARNING 2018-08-25 14:57:08 UTC RACKTABLES RACK ID EMPTY mod_a_alarm_low_water 10.50 V WARNING sys_alarm_high_temperature 2018-08-25 00:11:53 UTC 25 A 10.25 V 25 A WARNING mod_a_alarm_high_temp 2018-08-25 00:11:53 UTC 10.00 V WARNING mod_b_alarm_high_water 2018-08-25 00:11:53 UTC 20 A 9.75 V 20 A

15:18 15:19 15:20 15:16 15:17 15:18 15:19 15:20 Comment (0) Resolved Issues (5) of (546334) min max avg current min max avg current 10.00 V 11.00 V 10.47 V 10.35 V Voltage 11.00 V 12.00 V 11.53 V 11.49 V No comments yet. SEVERITY DESCRIPTION APPEARED AT RESOLVED AT 32.01 A 34.00 A 33.04 A 32.51 A Amperage 31.00 A 32.00 A 31.51 A 31.75 A ERROR sys_error_water_level_sensor 2018-08-27 12:27:11 UTC 2018-08-27 12:27:15 UTC

ERROR mod_b_error_flow_switch 2018-08-27 12:27:11 UTC 2018-08-27 12:27:15 UTC

ERROR mod_a_error_flow_switch 2018-08-27 12:27:11 UTC 2018-08-27 12:27:15 UTC Temperature Fan Speed

ERROR sys_error_press_switch 2018-08-27 12:27:11 UTC 2018-08-27 12:27:15 UTC 1 rpm

ERROR dryer_error_press_switch 2018-08-27 12:27:11 UTC 2018-08-27 12:27:15 UTC

ERROR dryer_error_heater_1 2018-08-27 12:27:11 UTC 2018-08-27 12:27:15 UTC

Add Comment All Issues

0 rpm

15:18 15:19 15:20 15:16 15:17 15:18 15:19 15:20 min max avg current min max avg current Fan 0 55.0oC 57.0oC 56.9oC 55.86oC Fan 2

Stack Pressure Outlet Pressure Status

Activity Steady

Module A Error OK

31.6 31.5 Module A Alarm OK

flow_switch Use Cases Enapter electrolysers are installed in numerous applications around the world. More examples are available on request.

France Malaysia Egypt

Off-grid with seasonal hydrogen Telecom back up power Telecom back up power energy storage Enapter electrolysers produce Enapter electrolysers generate Enapter electrolysers provide long hydrogen to keep this refuge in the hydrogen to power remote towers term backup capability for a tele- Alps operational year-round during a grid outage com tower in New Cairo close to the mosque Electrolyser : 500 NL/hr Electrolyser : 1000 NL/hr Fuel Cell : 2.5 kW Fuel Cell : 5 kW Electrolyser : 1000 NL/hr Storage : 5kg of hydrogen Fuel Cell : 4 kW (90 kWh) Storage : 500 L (1.35Kg)

Portugal Thailand Australia

Industrial onsite hydrogen 24 hour off-grid solar and hydrogen Energy independence in remote area generation

Enapter electrolysers are integrated The Phi Suea House, a world’s first Enapter electrolysers are the key into a nitrogen purification system in solar- hydrogen residential stor- component in this off-grid project age in the county of Melbourne Electrolyser : 1000 NL/hr Electrolyser : 2000 NL/hr Electrolyser : 1000 NL/hr Fuel Cell : 4 kW Fuel cell : 2 kW Storage : 7.5kg of hydrogen Storage : 300L (0.81 Kg) (130 kWh)

www.enapter.com [email protected]

Germany Italy Thailand Rheinsberger Str. 76/77, Via di Lavoria, 56/G - 56040 33/4 Moo4, Phi Suea House, San Phi Suea, 10115 Berlin (PI) A. Muang, Chiang Mai, 50300 +49 30 25814 7916 + 39 050 7620120 + 66 2 107 1104