WAYFINDING SIGN PROGRAM

Standards Manual

July 24, 2007 (Revised)

Prepared by Town of Breckenridge Signage Standards Manual 1 Introduction & Objectives

INTRODUCTION: OBJECTIVES OF THIS STANDARDS MANUAL:

The purpose of this manual is to provide 1. Provide unified and distinctive graphic identity standards for exterior signs and to establish a elements for the Town of Breckenridge consistent and controlled sign program within the Town of Breckenridge environment. All 2. Aid visitors, and residents to locate signs must conform to these standards. Use destinations easily. of consistent design, color, materials, logo, typography and size relationships will visually help 3. Facilitate traffic circulation and public safety. unify the Town of Breckenridge. 4. Enhance the visual environment of the Town These guidelines do not stand alone - they of Breckenridge. must be supplemented with the fabricator’s construction drawings in order to correctly 5. Provide an efficient implementation process manufacture and install signs within the town’s when additional signage is required. environment.

Sign function and usage varies within the Town of Breckenridge. Most of these variations have been anticipated and categorized in the manual. This manual provides guidelines for the addition of signage for the Town of Breckenridge.

Sign requirements vary from location to location. The examples shown in this manual may not address every future situation, but will assist you in selecting the appropriate sign type and format for a particular situation. Town of Breckenridge Signage Standards Manual 2 Manual Usage

HOW TO USE THIS MANUAL:

In the future, there will be instances where SUBMITTALS AND MATERIAL SAMPLES: additional signage and graphics will need Prior to the installation of any sign, the fabricator implementation. Through the use of this manual, will provide a complete set of construction Town of Breckenridge will be able to: drawings and a scaled graphic layout of the sign, indicating typography and graphics, mounting 1. Specify and locate the required sign type(s). location, and size for Owner/Design Workshop approval. 2. Create a message for the required signage. Additionally, powder coating and materials 3. Administrate the construction and installation samples should be submitted by fabricator for of the required signage. approval prior to fabrication.

As requirements for additional signage occurs, the The fabricator’s documents should be checked for cut sheets within this manual can be issued to a compliance with the following: particular vendor to obtain pricing information. 1. Proper placement, scale, material and color. To insure that a quality product is delivered, the fabricator should receive the ”Performance & 2. Sign message text and symbols must conform Material Requirements” in addition to any cut to the format(s) and typography described in the sheets for signs in this manual. appropriate sections of this manual.

The user of this manual should observe the 3. Sign messages should be brief and consistent characteristics of the existing signs of the town in nomenclature. Messages should not be for reference on the variety of messages and crowded on the sign face. All letter spacing and usage of particular sign types, as well as mounting line spacing should be consistent with what is and locations. shown for appropriate sections of this manual. Abbreviations should be avoided if possible. FOR SIGN LOCATIONS AND MESSAGES, PLEASE REFER TO THE FOLLOWING DOCUMENTS AVAILABLE FROM THE TOWN OF BRECKENRIDGE:

PLANS: Sign Location , Phase I

MESSAGE SCHEDULE: Signage Content Spreadsheet, Phase I Town of Breckenridge Signage Standards Manual 3 Approved Font and Symbols for Signs

TYPEFACE: The exterior sign family utilizes the fonts Highway Gothic-C Series and Champers. No other alternate typefaces are permitted.

The typography shall never be distorted to fit within a particular size or format. Letter spacing Town of Breckenridge Logo and line spacing shall always comply with examples shown in this manual.

ARROW SYMBOL: Arrow symbols used on the message panels for Town of Breckenridge Logotype exterior signage shall always match the proportion of the symbol indicated. The arrow symbol shall never be distorted to fit within a particular size or format. Utilize the examples shown on appropriate cut sheets of this manual for size and spacing of arrow symbols in relation to typography as it is used on message panels. Arrow Disabled Parking

ABCDEFGHIJKLMNOP QRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890 PRIMARY: Highway Gothic-C Series ABCDEFGHIJKLMNOP QRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890 SECONDARY: Champers Town of Breckenridge Signage Standards Manual 4 Exterior Sign Color Palette

POWDER COATINGS & STAIN COLORS: of all materials utilized for fabrication. For color The exterior sign family utilizes the colors shown matching to sample(s): Samples are available from below. All powder coating finishes should match Design Workshop or Town of Breckenridge. the indicated gloss level on the appropriate cut sheet. The color samples on this sheet are for 3M ADHESIVE VINYL: reference only. The fabricator shall match powder The sign fabricator shall use 3M Scotchlite High coat color using actual paint samples. Intensity Reflective or Scotchcal graphic film (opaque) as specified. MATERIALS: The sign fabricator shall match the specifications indicated in this manual for proper color match PAINT COLORS: PAINT P-1: Tiger Drylac P-2: Tiger Drylac P-3: Tiger Drylac P-4: Tiger Drylac Powder Coating: “Sahara Series 38 Powder Series 38 Powder Series 38 Powder Gold” 49/90137 Coating. Custom Coating. Color: T.B.D. Coating. RAL 9017 match to Corten 38/80017 (Black) Steel. STAIN COLORS: STAIN S-1: To be determined. VINYL COLORS: V-1 3M Scothchlite V-2 3M Scotchcal V-3 3M Scotchlite V-4 3M Scotchlite High Intensity “Antique White” High Intensity High Intensity Reflective Sheeting #7725-90 Reflective Sheeting Reflective Sheeting White #3870, 6870 Brown #3879, 6879 Blue #3875 Town of Breckenridge Signage Standards Manual 5 Fabricator Qualifications

I. ACCEPTANCE OF PERFORMANCE & colors and construction details. Shop drawings MATERIAL REQUIREMENTS should be produced using a computer aided Acknowledgement and acceptance of the drafting program (Illustrator, Freehand, performance and material requirements are AutoCad, Corel Draw, etc.) and should never required for the implementation of The be hand drawn, unless the hand drafted Town of Breckenridge Signage Program. drawings are of equal or greater quality than In order for consideration for fabrication that of a computer aided drawing. All shop of the Signage Program for The Town of drawings that do not meet Owner/Design Breckenridge, sign contractors must accept Workshop standards will be required to be the terms of the performance and material resubmitted. requirements by signing their name below. Required Shop Drawing samples: - One (1) Sample Shop Drawing for Name Sign Type A2 Company______All sign contractors and required to be insured Date:______and have the necessary funds to sustain a project of The Town of Breckenridge II. SAMPLE SUBMITTALS Signage Program magnitude. Case studies Shop drawings are required to insure accuracy of the fabricator’s project history should be and understanding of the design intent for submitted prior to bid review. The Town of Breckenridge Signage Program. Shop drawing details should be extensive, listing all materials, sizes/margins, typestyles, Town of Breckenridge Signage Standards Manual 6 Specific Sample Submittals

In addition to general paint and material samples, the following specific samples are required:

A SERIES: VEHICULAR SIGN TYPES B SERIES: PEDESTRIAN SIGN TYPES Phase 1: Phase 2: A1 Town Gateway Monument: One (1) Full Size B1 Pedestrian Directional: with Town Map: One letter “B” (Breckenridge) and stone sample. (1) full size finial, typical directional arm and map case. A2 Primary Vehicular Directional: One (1) Full Size “Sun Burst” and typical message panel. B2a Secondary Pedestrian Directional: Main Street: None. A3 Secondary Vehicular Directional and Brecken- ridge Town Limit ID: None. B2b SecondaryNot Pedestrian in Contract Directional: River Walk: None. A4 Tertiary Vehicular Directional: One (1) Full Size sign. B3 Bus Route Map” One (1) Full Size “Bus Stop” Identification sign and Route Map/Sched- A5 Vehicular Destination Directional: None. ule case.

A6 Historic District ID: One (1) Full Size partial Note: In the case of a full size sign submittal, if corner sample of case plaque, fastener hardware approved, the sign can be used in the actual sign and finial. program installation.

A7 Vehicular Parking Directional: One (1) com- plete Full Size sign and attachment hardware.

Phase 2: A8 Vehicular Street ID: Main Street: One (1) Full Size sign.

A9 Secondary Vehicular Street ID: None Not in Contract A10 Vehicular Regulatory Signs: None.

A11 Banner Armature: One (1) Full Size sign. Town of Breckenridge Signage Standards Manual 7 Performance & Material Requirements

I. These Fabricator Performance and Material The acceptance of these drawings by vendors, Requirements are an integral part of the bidders, fabricators, or contractors and their Manuals. The fabricator, subcontractor and agents constitutes agreement to the following the general contractor are responsible for conditions: all aspects of fabrication identified in this document. Any exclusions or substitutions to this document or to the Design Intent III. DESIGN INTENT DRAWINGS Drawings must be stated in writing to the A. Design intent drawings are for the Owner/Design Workshop at the time of bid. sole purpose of design intent only and not intended for construction purposes.

II. PROPRIETARY INFORMATION NON- B. Resulting working drawings, shop DISCLOSURE AGREEMENT drawings and contract documents All ideas, designs, arrangements and plans including permit documents are the sole indicated or presented by these drawings responsibility of the contractor in every are owned by and are the property of the respect. Owner, and were created, evolved and developed for use on and in connection C. The Owner/Design Workshop with the specified project. None of such shall review the shop drawings only for ideas, designs, arrangements or plans shall conformance with general design intent, be used by or disclosed to any person, firm, and will in no way be responsible or liable or corporation for any purpose whatsoever for any results of construction from without the written permission of the working drawings, material selection, shop Owner/Design Workshop. Any and all drawings, contract documents or any inquiries in this regard by outside parties other agreements other than agreement should be referred to the Owner/Design with the Owner authorizing these Workshop. In addition, The Fabricator must documents. request and receive written approvals to use images of any completed element described D. Any Owner requested changes after in these documents in print or promotional this document has been completed will be materials of any kind including video, from considered additional services. Owner/Design Workshop in order to proceed with publication. Permission to use images of the work for promotional or IV. QUALITY ASSURANCE editorial purposes requires that the Fabricator A. Quality of Workmanship be responsible for ensuring that credit The contractor shall be responsible for indicating Design Workshop as the designer the quality and delivery of all materials be adjacent to those images. If an article in a and workmanship required for the publication accompanies the images, Design execution of the contract including Workshop must be identified as the designer the materials and workmanship of any in that article as well. The Owner may have firms or individuals who act as his or additional requirements or restrictions for her subcontractors. Contractors shall be which the Fabricator is also responsible. responsible for providing subcontractors with complete and up-to-date drawings, performance and material requirements, All original artwork (including electronic graphic schedule and other information files) furnished by Design Workshop must be issued by the Owner/Design Workshop returned upon completion of this project. B. Performance The contractor shall base his or her Town of Breckenridge Signage Standards Manual 8 Performance & Material Requirements

proposal on the performance of all services, including all items of labor, G. Artwork materials and equipment required for the CD or DVD with electronic artwork complete fabrication and installation of as required by the sign contractor for the specified work within the timeframe symbols or custom designed graphic agreed to by contractor, Owner/Design components (i.e.: logos, logo types, Workshop arrows, or patterns) will be provided in Adobe Illustrator CS format at a C. Dimensions scaled percentage of the final size. The Written dimensions on the drawings shall appropriate Adobe Photoshop .eps scan take precedence over scaled dimensions. will also be provided when necessary. All Contractor shall verify and be responsible required copy layouts and text for project for all dimensions and conditions shown signage system is the responsibility of by these drawings. the sign contractor. All enlarging and reducing is the responsibility of the sign D. Sign Package Message Schedule contractor. Contractor shall submit an (“Signage Content Spreadsheet”) itemized list of all required artwork at Copy, quantities and references shown on time of bid. Note: Any artwork required the “Signage Content Spreadsheet” shall beyond electronic computer artwork take precedence over drawings. The large noted above (i.e.: additional custom copy scale details shall take precedence over the layouts, formatting for other platform(s), smaller scale drawings. linotronic output, or copying to other media, etc.) will be billed to the contractor E. Execution on a time and materials basis by Design Contractor shall notify the Owner/ Workshop. Design Workshop cannot Design Workshop of any discrepancies provide copies of licensed fonts. in the drawings or Message Schedule, in field dimensions or conditions, and/or Stock Photo Images: Design Workshop changes required in construction details. will provide placed electronic files for Problems such as messages being too stock photo images indicated on the long to fit into the required formats, drawings as digital output on solid vinyl, difficulty accurately reproducing logo scrim, mesh or other materials. These files or logotype components, etc., must be are for composition and layout purposes brought to the attention of the Owner/ only. High resolution final images and any Design Workshop prior to execution. It other associated fees or other costs are is required that the contractor not resolve the responsibility of the fabricator and any discrepancies without consulting the should be obtained from the specified Owner/Design Workshop. stock photo vendor by the fabricator and registered in the Owner’s name. Scans F. Contractor Recommendations or negatives as well as any additional The contractor shall carefully study the computer file manipulation time required detailed drawings and make specific are the responsibility of the fabricator. recommendations for changes if those changes will improve the quality of any H. UL Compliance fabrication. Such recommendations Complete UL, or approved nationally and changes including any changes in recognized testing agency, compliance, contract amount shall be approved in as required, is the responsibility writing by the Owner/Design Workshop of theNot contractor. in Contract Contractor shall prior to preparation of shop drawings or provide lighting fixtures and electrical fabrication. components that meet all UL testing lab Town of Breckenridge Signage Standards Manual 9 Performance & Material Requirements

requirements for safety, operation, and V. SUBMITTALS construction. Fixtures and components A. Shop drawings must be UL-labeled and listed and shall The contractor shall submit three sets of indicate locations and electrical service detailed shop drawings (2 sets of prints, required for review by the Owner and 1 reproducible set of plans, elevations DesignNot Workshop in Contract unless noted otherwise. and scale drawings) to the Owner/Design Contractor is responsible for all final Workshop for review prior to production. electrical connections. These drawings are to show/indicate all materials, finishes, construction I. Lamp Emission details, lighting requirements, installation All lighting fixtures/sources shall emit a details, artwork and structure, including color balanced, consistent and uniform locations of all material seams (finished light withNot no browning,in Contract flickering, and unfinished). Shop drawings and haloing, or other uneven effect. data shall be reviewed by the Owner/ Design Workshop with such promptness J. Electrical Hardware as to cause no delay in the work. The All transformers and electrical hardware contractor shall make all corrections shall be concealed, non-audible and non- required and resubmit for final review. visible to pedestrian and vehicular traffic. Final reviewed shop drawings noted Provide disconnect switch if required by “No Exceptions Taken” or “Exceptions governing agencies. as Noted” must be received from the Owner/Design Workshop before K. Labeling production starts. There shall be no visible labels, manufacturer’s or otherwise, code Shop drawings will be reviewed for permitting, on the completed signs or compliance with design intent only. The other objects. If labels are required, a contractor is responsible for engineering sample label and intended location along each object to meet all load and wind with an explanation of the requirement requirements with sealed drawings must be submitted for Owner/Design and calculations by certified engineers. Workshop review, prior to application The contractor is responsible for all and/or installation. other aspects of fabrication including engineering, procedure, installation L. Stock techniques and performance as well as All materials, hardware, electrical coordination with site conditions and components, finishes, etc. used to related trades. fabricate any and all components shall be “NEW” (not previously used or operated B. Product Data in any other application) and from the The contractor shall submit most recent original manufacturer’s manufacturer’s technical data and production run/supply and appropriately installation instructions for each matched to the service conditions fixture provided within the completed, required of the site. installed unit. Contractor shall provide identification of all materials used, M. Testing including manufacturer’s descriptive An independent testing lab may be hired by literature, control number, name, code the Owner to do inspection and material number, batch and formula (when testing as required. Do not proceed with available). the work until unsatisfactory conditions have been corrected by the contractor in a manner acceptable to the Owner. Town of Breckenridge Signage Standards Manual 10 Performance & Material Requirements

C. Specific Samples requirements and support/blocking The contractor shall submit a minimum requirements for each element (including of three (3) samples (minimum size 6” approximate weight). x 6” or as requested by Owner/Design Workshop) of each color and finish on G. Lamp Service the specified materials. Samples must The contractor shall provide the Owner be submitted in a timeframe allowable with complete lamp replacement for review, multiple adjustments, and information, brand, type, wattage, color, approval without delay to the project. etc., for all lighted components. This The Owner/Design Workshop’s review informationNot shallin Contract be in a typewritten of samples will be for color, texture, format (8-1/2” x 11”) and shall indicate at and aesthetic compatibility with existing least one local (site) supplier. or adjacent materials. Compliance with all other requirements is the exclusive H. Maintenance responsibility of the contractors. When The contractor shall provide the Owner specified, furnish full-size samples of with complete finish/component objects, partial objects, and/or materials. care instructions as specified by the Resubmit samples if requested until manufacturer for on-going cosmetic required sheen, color, texture, and cleaning and maintenance. Three sets compliance with Fabricator Performance are to be submitted in an 8-1/2” x 11” and Material Requirements is accepted. 3-ring binder. Turn over to Owner one (1) unopened gallon of each color/finish D. Structure used on the project clearly marked with Design of installation, internal structure, complete specification and “P” color mounting assemblies and foundations are reference. by contractor. Contractor shall submit three sets of prints and one reproducible I. Copy/Text Layouts set of comprehensive engineering The contractor shall provide full size drawings to the Owner/Design copy layouts for all signs. Layouts must be Workshop incorporating an adequate submitted in a time frame allowable for foundation and/or mounting structure review, multiple adjustments and approval for all sign components to meet all load without delay to the project. and wind requirements and given site conditions. The contractor shall, at his or J. Large Format Digital Output her expense, submit for Owner/Design A 12” by 24” portion of the final full Workshop’s review, calculations, sealed size computer output of each image is by certified engineers registered in the required to be submitted to the Owner/ state of final installation, for all structural Design Workshop for approval prior to members including foundations. final production.

E. Custom Fabricated Items The contractor is to submit shop VI. FINISHES drawings of all custom fabricated items A. Colors and Surface Textures and specifications on all standard pre- All colors shall match exactly the color manufactured items. and finish requirements provided by the Owner/Design Workshop. For F. Electrical Requirements exposed signage, materials with applied Contractor shall, within five days of colors or other characteristics related to contract execution, provide the owner and appearance, contractor shall provide color general contractor with a list of electrical matches indicated, or if not indicated, Town of Breckenridge Signage Standards Manual 11 Performance & Material Requirements

as selected and reviewed by the Owner/ streaking, spotting, gradation, or other Design Workshop. variations within and from each similar application. B. Surface Preparation All surfaces shall be thoroughly cleaned E. Ultra-Violet/Fading Protection and free from dust, dirt, rust, scale, mill Contractor shall utilize materials, coatings scale, oil, greasy materials or residue from and processes to minimize as much cleaning. All coatings shall be applied in as possible any noticeable fading of strict accordance with the manufacturer’s pigmented coatings. recommendations. All paint products shall conform to local codes. All finishes shall present a uniform opaque color VII. MATERIALS appearance unless specifically indicated A. Acrylic Color Translucent Sheet otherwise by the Owner/Design Where sheet material is indicated as a Workshop. “color” provide color translucent sheet of density required to produce uniform C. Painted Finish brightness without halo-like effect. 1. Ferrous Surfaces Material provided shall be appropriately Using Matthews paint products, matched to the intended permanent field finish with 1 coat 74-734 & 74-735 conditions. Metal Pretreat @ .25 mils DFT, 1 coat Matthews Acrylic Polyurethane B. Acrylic/Transparent Sheet 1 mil DFT (min.). Observe designer’s Where sheet material is indicated as specification regarding specularity “clear” provide colorless sheet in gloss (matte to gloss). finish, with light transmittance of 92%, where tested in accordance with the 2. Aluminum requirements of ASTM D-1103. Using Matthews paint products finish, with 1 coat 74-734 & 74-735 C. Aluminum Sheet Metal Pretreat @ .25 mils DFT or Provide aluminum sheet of alloy and 1 coat 74-793 Spray Bond @ .15 to temper recommended by the aluminum .25 mils DFT and 1 coat Matthews producer or finisher for the type of use Acrylic Polyurethane 1 mil DFT and finish indicated and with not less (min.). than the strength and durability properties specified in ASTM B109 for 5005-H15. 3. Bright Metals Match finish (polished, satin, D. Aluminum Extrusions brushed, etc.) detailed on drawing. If Provide aluminum extrusions of alloy and specified, finish with a polyurethane temper recommended by the aluminum clear coat warranteed against producer or finisher for the type of use yellowing for seven years. and finish indicated and with not less than the strength and durability properties 4. Plastic Surfaces specified in ASTM B-221 for 6063-T5. All plastic to be paint finished according to paint manufacturer’s E. Structural Steel specifications. Provide internal structural steel as required to meet the requirements of the D. Application permanent installation. All applications of color/coatings are to be equal and of consistent cover with no Town of Breckenridge Signage Standards Manual 12 Performance & Material Requirements

F. Fasteners components. Make provisions for Unless otherwise indicated, provide servicing and for concealed connection concealed fasteners fabricated from to the building system. Coordinate all metals that are non-corrosive to either the electrical components with those of the signage materials or the mounting surface. power supply provided.

G. Vinyl Machine-Cut Copy C. Signage/Cabinet Vinyl machine-cut copy shall be of 3M Details shown on the drawing shall Scotchcal brand film or approved equal. be followed for exterior appearance. Structural design shall utilize unitized, H. Powder Coating self-supportive framing. Fabricate Powder coating shall be equivalent to cabinet, exposed faces and graphic Tiger Drylac Series 38: Super durable, devices to size and style indicated and highly weather and UV resistant. Apply produce surfaces free from oil canning, finish according to manufacturer’s warping, distortion or any irregularities or specifications. inconsistencies. Include internal bracing for stability and attachment of mounting I. Paint accessories as required. Contractor may Paint shall be contractor’s highest grade change interior construction shown for best ultraviolet light resistance, on these details to conform with his weatherability, and overall longevity shop practices. However, these changes of finish and color. Where possible, must be submitted as part of the shop use water-based, 100% solids, high drawings and be reviewed and accepted performance acrylic instead of solvent- by the Owner/Design Workshop prior to based paints. If solvent-based paints fabrication. must be used, use products that are low-VOC (<380 g/l) and <1% aromatic D. Fastenings hydrocarbons by weight. Paint shall have a 1. Fasteners on all visible surfaces written warranty against premature fading shall not be exposed, except where and be approved by Owner/Design noted. Workshop prior to construction. Prior to close-out, contractor shall turn over 2. Surfaces shall not be penetrated to Owner 3 copies of complete paint during fabrication or installation, schedule indicating all colors used. except where noted.

3. Surfaces shall not be deformed, VIII. FABRICATION distorted, or discolored by attachment A. Copy Application of concealed fasteners. Provide copy to comply with the requirements indicated for size, style, 4. All fasteners shall be resistant to spacing, content, position, material, finish oxidation or other corrosive action and color of letters, numbers, symbols completely through their cross and other graphic devices. sections.

B. Illumination 5. Work shall be secured with Illuminate units in the manner indicated fasteners of the same metal, color using the manufacturer’s standard lighting and finish as the components they components including: fluorescent, secure where they are exposed to view. incandescent and/or neon, fixtures, transformers, insulators and other Town of Breckenridge Signage Standards Manual 13 Performance & Material Requirements

6. Fasteners shall be utilized in strict Design Workshop Visible abrasions to accordance with their manufacturer’s finished surfaces must be repaired so that specifications, directions, damage is not visible. recommendations and as indicated on Design Intent Drawings. C. Installation of all items shall be by the contractor. Installation includes E. Aluminum Sheet provision of any required footings, all Not less than 0.125” thick unless noted anchor bolts, fastenings, attachment otherwise. Fabricate by the HELIARC metals, and other miscellaneous metal or MIG welding process with all visible items embedded in concrete or building seams continuously welded, filled and wall material as required, and security of ground smooth, unless the seam occurs units in place with no visible fasteners. along a color break. Then a clean butt joint with concealed backing channel D. The contractor will be responsible and plug weld is finished to match for any damage caused to building, site, surrounding material finish. All blinds, and adjacent objects or elements during curves, and folds to be geometrically installation. The contractor shall be correct and produced by a consistent responsible for cleaning up all work areas mechanical method unless approved upon the completion of their work, on a otherwise by the owner/Design daily basis. Workshop E. The contractor shall provide required F. Jointing and Brake Forming electrical equipment and connection to All sheet metal shall have brake formed shell building. The point of connection is edges with radii not greater than sheet to be provided by the General Contractor. thickness unless otherwise specified. All electrical connections shall be made Adjacent stock shall have edges with by a licensed electrician employed by similar radii. the contractor for this purpose. All connections shall be made in accordance G. Welding with the requirements of the National All exposed welds are to be ground Electrical Code (N.E.C.) in addition smooth and filled to match surface of to all applicable local codes. Electrical adjacent material. contractor shall provide and install all wiring, conduit, junction boxes and electrical devices necessary to provide IX. INSTALLATION electrical power to rough-in connections A. Contractor shall be responsible for unless otherwise noted. Contractor determining the erection and dismantling shall provide all electrical connections of all barricade or protective coverings beyond rough-in connections by electrical necessary to safeguard the public and contractor, according to N.E.C. approved property during the performance and methods. duration of his or her work. F. Contractor shall be responsible for B. Contractor shall attach objects matching electrical service available on to substrates in accordance with the site to the requirements of the object, project structural engineer’s and the including transformers. manufacturer’s instructions unless otherwise shown. Install level, plumb, G. All necessary electrical components and at proper height. Repair or replace as well as the entire assembly are to be damaged units as directed by the Owner/ UL listed, or by approved nationally recognized testing lab. Town of Breckenridge Signage Standards Manual 14 Performance & Material Requirements

H. Contractor is responsible for 2. No cupping, warping or dishing. compliance with all applicable environmental regulations. 3. No bubbling, crazing, chalking, rusting or other disintegration of I. Contractor is responsible for surfaces, messages or edge finishes. compliance with all OSHA regulations. 4. No corrosion developing beneath J. Contractor shall be responsible for the powder coated surface of the coordination of all elements with the support systems, except as the result sub-contractors and trades people relative of obvious vandalism. to this work. These coordination efforts will include, but not limited to: deliveries, 5. No corrosion of the fasteners. work schedules, and installation. Storage space at the job site is limited and will also 6. No movement of objects from require coordination and/or approval. their foundations. The objects must Materials or finished work stored at the remain true and plumb on their job site without prior permission may be foundations, except when obvious relocated at contractor’s expense. post-installation external damage has occurred.

X. CLEANING/PROTECTION AND 7. No fading of the colors when WARRANTIES matched against a sample of the A. All items to be installed by the original color and material. contractor shall be left in a clean and as- new condition. Upon completion of the 8. No variation of any other installation, clean all soiled surfaces and performance stated by Design touch up all finishes in accordance with Workshop on the drawings or in the the manufacturer’s instructions. All debris Fabricator Performance and Material and packing material shall be removed Requirements. and disposed of in a legal manner. The protective masking of the plastic surfaces C. Structure/Components shall be removed by the contractor upon Contractor shall provide Owner with completion of installation. All excavation 3 copies of the written warranty prior and site work shall be returned to its to installation guaranteeing to correct, original grade configuration after contract to Owner’s satisfaction, at contractor’s items are installed sole expense, all defects in fabrication and installation of work for a period of B. Finish Surfaces one year after Owner’s acceptance of All units shall be warranteed in writing completed installation. by the contractor for a period of no less than 3 years from the date of Owner D. External Lamps acceptance. All finishes (except large All lamps shall be warranted against format computer output) are to be failure for 90 days, all neon three years, warranted for 3 years from the date of and all ballast one year. Lamps are to Owner acceptance. There shall be: be replaced within 48 hours of notice by Owner and/or General Contractor. 1. No delamination of any portion In the eventNot ofin failure Contract within specified of the object including vinyl graphics times these items are to be replaced by and copy. contractor at contractor’s sole expense. Town of Breckenridge Signage Standards Manual 15 Performance & Material Requirements

E. The contractor shall have total and personnel necessary to execute the complete responsibility for the security contract without first contacting the of all equipment, materials, and sign Owner for permission. components until reviewed and accepted by the Owner. XII. LARGE FORMAT COMPUTER OUTPUT F. Lamp Service All high resolution large format computer The contractor shall provide Owner with output indicated in this manual must 3 copies of complete lamp replacement comply with the following: information, brand, type, wattage, color, 1. Minimum resolution: 200 dpi, or as etc., for all lighted components. This approved by Design Workshop information shall be in a typewritten 2. Process: 3M SCOTCHPRINT (or format (8-1/2” x 11”) and shall indicate at approved equal). least oneNot local in(site) Contract supplier. Lamps must 3. Substrate: Opaque or Translucent comply with all local, state, and federal Scotchcal film (or approved equal). regulations. 4. Finish: 2 mil Matte overlaminate. 5. Input: Electronic art as specified. G. Maintenance 6. Warranty: Product must be warranted The contractor shall provide to Owner against color fading, UV damage, 3 copies each of complete finish/ delamination, shrinkage or peeling for a component care instructions as specified minimum of five (5) years from date of by the manufacturer for on-going installation. cosmetic cleaning and maintenance. These are to be submitted in an 8-1/2” x 11” 3-ring binder. Contractor to ensure XIII. BID NOTES signage, neon, lamps, and electrical Original fabrication quotes shall be components etc. are easily accessible for sent directly to the Owner with copies maintenance. of all pricing information to be sent simultaneously to Design Workshop.

XI. PERMITS Pricing shall be submitted in accordance A. Securing and paying for all permits with the bid documents. required by governmental agencies is the responsibility of the contractor. Bidders are required to clearly indicate in Inspections and tests necessary for the writing within their bid the method of construction and placement of all work construction anticipated, the materials to required by the applicable governing be used, and any exclusions or exceptions agencies is by the contractor. to the bid documents.

B. Contractor shall secure and pay for all insurance required by law including: Liability, Worker’s Compensation, Comprehensive, Constructural Liability, Personal Injury, Comprehensive Auto and Property on- and off-site.

C. Contractor shall not reveal or disseminate any information to any person(s), private or public, other than Design Workshop, Owner or contractor’s Town of Breckenridge Signage Standards Manual 16 Exterior Signs: List of Sign Types

A SERIES: VEHICULAR SIGN TYPES Phase 1 A1 Town Gateway Monument A2 Primary Vehicular Directional (Highway 9) A3 Secondary Vehicular Directional (Park Avenue) and Breckenridge Town Limit A4 Tertiary Vehicular Directional (Park Ave. & other roads off Park Ave.) A5 Single-post Vehicular Directional A6 Historic District ID A7 Vehicular Parking Lot Directional (Main Street) Phase 2 A8 Vehicular Street ID: Main St. & Park Ave. A9 VehicularNot Street in Contract ID: Neighborhoods A10 Vehicular Regulatory Signs A11 Banner Armature

B SERIES: PEDESTRIAN SIGN TYPES Phase 2 B1 Pedestrian Directional: with Town Map B2a Secondary Pedestrian Directional: Main Street (Map with directional messages) B2b SecondaryNot inPedestrian Contract Directional: RiverWalk (Map only) B3 Bus Route Map Town of Breckenridge Signage Standards Manual 17 Sign Type A1, Town Gateway Monument: Retrofit/Upgrade

DESCRIPTION: The Gateway Monument Sign LOCATION: See Town Sign Location Map, identifies the visitor’s arrival to the Town of Phase I. Breckenridge from Highway 9. The sign takes design cues from the rustic mountain landscape NOTES: Refer to sign fabricator shop drawings of Breckenridge. for all construction details and additional information. CONTENT GUIDELINES: The Town of Breckenridge logo type-style occurs as shown. This design and type of sign will only occur once Sign is single-sided (message reads on sign facing at the entrance of the town. No such sign design road only). shall occur within the town beyond the entrance of the town. TYPEFACE: Champers and Town Logotype.

CONSTRUCTION: Remove old letters. Re- clad existing wall with dry-stack appearance stone to match “Canyon City Quarry” stone. Add logo “peak” form to top of wall. “BRECKENRIDGE” letters are fabricated aluminum with 3” returns, while all other letters and graphics are 1/2” flat cut aluminum. Letter Existing Sign on Highway 9 faces are to be powder coated, P-3. Mechanically fasten letters to monument face in a permanent manner with no exposed fasteners on face of letters. Spot illuminate face of stone wall. Fixtures to be shrouded for dark sky ordinance.

Note: Final letter color is to be determined. A selection of three sample colors will be tested on re-clad stone wall prior to a final color selection. “Canyon City Quarry” stone example

15'-4"

8-1/2" 9'-0" 5-1/2"

1'-0" ESTABLISHED 1859 5-1/2"

SIGN TYPE A1 TOWN GATEWAY MONUMENT (Retrofit/Upgrade) Scale: 1/4”=1’-0” Town of Breckenridge Signage Standards Manual 18 Sign Type A2, Primary Vehicular Directional

SIGN TYPE A2 Primary Vehicular Directional 3D Perspective Rendering Not to Scale Town of Breckenridge Signage Standards Manual 19 Sign Type A2, Primary Vehicular Directional, continued:

DESCRIPTION: The Primary Vehicular Posts/Structure: 10” square penofin treated rough Directional sign provides vehicular directional sawn cedar wood posts with chamfer edges. Stain information on Highway 9 as visitors approach color: S-1, to be determined. the Town limits. This sign type has flexible sign panels-from one to four. The sign takes design Back Face and Sign Background: Corrugated cues from the victorian architecture of the town aluminum (vertical). and the rustic mining history in the region. Sign Message Panels: Removable 1/4” individual CONTENT GUIDELINES: Sign is single-sided aluminum panels with beveled edges on top with copy, arrows and corresponding . and bottom only. Message background: V-3. Text, arrows and pictograms: V-1. Parking and TYPEFACE: Highway Gothic, Series C. Information : V-1 and V-4. Secure panels to background with exposed fasteners as CONSTRUCTION: Post and panel with penofin specified. treated rough sawn cedar wood, powder coated metal and corrugated aluminum. High Intensity Post Bases: 1/4” thick fabricated corten steel. Reflective vinyl message panels. 9'-3" 1'-5" 7'-0"

2-1/2" Sq. 9 5/8" 3'-2"

3" 3" 1-1/2" 3" 1-1/2" 1-1/2" � Parking 6" � Transit Station 6" 3'-10" 4'-1" � Riverwalk Center 9'-10" � Ice Arena 11-1/2"

6'-7" 10" 6"

10-1/2" 2'-0"

SIGN TYPE A2 Primary Vehicular Directional Scale: 1/4”=1’-0” Town of Breckenridge Signage Standards Manual 20 Sign Type A2, Primary Vehicular Directional, continued:

Sign Cap & Brackets: Fabricated aluminum, powder coated P-2 to match corten steel. Sunburst: 1/4” thick aluminum, powder coated P-2 to match corten steel.

Footing: Break-away post base (see detail).

LOCATION: See Town Sign Location Map, Sign Fabricator is to produce clear, Phase I. unpixelated images of standard highway symbols. This symbol may be NOTES: Refer to sign fabricator shop drawings achieved using digital Gerber Edge® for all construction details and additional vinyl prints or die-cut vinyl graphics information. with appropriate color scheme.

9'-3"

9'-10"

SIGN TYPE A2 Primary Vehicular Directional Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 21 Sign Type A2, Primary Vehicular Directional, continued:

Section View of Chamfer

9'-3"

9'-10"

SIGN TYPE A2 Primary Vehicular Directional-Back Face Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 22 Sign Types A2 and A3 Material Details (A4 similar)



























Exploded See following page for key Town of Breckenridge Signage Standards Manual 23 Sign Types A2–A4 Material Details, continued:

1 1” blackened acorn nut. 8 Corrugated natural satin Quantity of (8) on each post aluminum background panel. base. Quantity of (2) per sign.

2 9 Post Base 1/4” thick fabricated Penofin treated rough sawn corten steel. cedar wood horizontal cross member.

3 10 Square penofin treated rough 2” Cube powder coated P-2 to sawn cedar wood posts (sizes match corten steel and set into vary) with chamfered edges. #9 wood cross member. Note that chamfer ends into a square edge.

4 11 Decorative 1” aluminum bar Penofin treated rough sawn stock L-Support, powder coated cedar wood horizontal cross P-2 to match corten steel. member. Larger than #9.

5 12 Penofin treated rough sawn Fabricated aluminum Sign Cap cedar wood cross-beam support. powder coated P-2 to match corten steel. Routed Channel for Sun Burst

6 13 5/8” blackened acorn nut. 1/4” thick flat cut aluminum Quantity varies based on number Sun Burst attached to the inside of sign panels. pitch of Sign Cap powder coated P-2 to match corten steel. 7 Removable 1/4” individual aluminum panels with beveled edges on top and bottom only. Message background: V-3. Text, arrows and pictograms: V-1. Parking and Information pictogram: V-1 and V-4. Secure panels to background with exposed fasteners as specified. Town of Breckenridge Signage Standards Manual 24 Sign Types A2 and A3 Flexible Sign Panel Options

OPTION 1 OPTION 2 4 panels 3 panels

OPTION 3 OPTION 4 2 panels 1 panel

1/4" 1/8"

Beveled Edges located at top and bottom of sign panel only. Town of Breckenridge Signage Standards Manual 25 Typical Break-away Footing Detail

varies

Tamper-proof blackened acorn nut fasteners

Connection to be Break-away

3/4" Finished grade

45° chamfer

Non-shrink groutF 3/4" or leveling. 4"

Diameter and depth of concrete Footing to be determined by sign fabricator per local code.

30 0 0 p s i c o n c r e t e f o ot i n g

Typical Footing Detail Scale: 1-1/2”=1’-0”

Town of Breckenridge Sign Program Design Presentation: January 9, 2007 Town of Breckenridge Signage Standards7'-2" Manual 26 7'-2" 2'-4" 2'-6" 2'-4" 2'-4" 2'-6" 2'-4" Sign Type A3a, Secondary Vehicular Directional and Breckenridge Town Limit 8" 9" 8" 9" 2-1/2" 2-1/2" 2-1/2" 2-1/2" DESCRIPTION: The Secondary Vehicular Reflective vinyl message 2-1/2"panels. 2-1/2" Directional and Breckenridge Town Limit Posts/Structure: 7-3/4"8” square penofin treated rough � Parking 10-3/8" signs welcomes visitors and provides directional sawn cedar wood posts with chamfer edges. Stain Police Station � information. The sign takes design� cuesTransit from the Station color: S-1, to be determined. 3'-0" 2'-7" 3'-0" 2'-7" � victorian architecture of the �town and the rustic Recreation Center mining history in the region. Riverwalk CenterBack Face and Sign Background: Corrugated 5'-1" 5'-1" � Ice Arena aluminum (vertical). Kingdom Park � CONTENT GUIDELINES: Single-sided 8'-5 1/2" 8'-5 1/2" directional messages guide visitors to destinations Sign Message Panels: Removable 1/4” individual throughout the town. The Town of Breckenridge aluminum1/2" panels with beveled edges on top 1/2" 5" 5" logo type-style occurs as shown. Sign is double- and bottom only. Message background: V-3. sided with a “welcome” message on the front5'-0" and Text, arrows and pictograms: V-1. Parking and 5'-0" a “thank you” message on the back. 5'-6" Information pictogram: V-1 and V-4. Secure 5'-6" panels to background with exposed fasteners as TYPEFACE: Highway Gothic9" Series C and specified. 9" Champers. 2'-0" 2'-0" Post Bases: 1/4” thick fabricated corten steel. CONSTRUCTION: Post and panel with penofin treated rough sawn cedar wood, powder coated Sign Cap & Brackets: Fabricated aluminum, metal and corrugated aluminum. High Intensity powder coated P-2 to match corten steel.

7'-2" 7'-2" 2'-4" 2'-6" 2'-4" 2'-4" 2'-6" 2'-4" 8" 9" 8" 9" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 7-3/4" � Parking Police Station � 10-3/8" � Transit Station 3'-0" 2'-7" 3'-0" 2'-7" Recreation Center � � Riverwalk Center � 5'-1" Kingdom Park � 5'-1" Ice Arena 8'-5 1/2" 8'-5 1/2"

1/2" 1/2" 5" 5" 5'-0" 5'-0" 5'-6" 5'-6"

9" 9" 2'-0" 2'-0"

SIGN TYPE A3a Secondary Vehicular Directional-4 message panels Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 27 Sign Type A3b, Secondary Vehicular Directional

Sunburst: 1/4” thick aluminum, powder coated P-2 to match corten steel.

Footing: Break-away post base (see detail).

LOCATION: See Town Sign Location Map, Phase I.

NOTES: Refer to sign fabricator shop drawings for all construction details and additional information.

7'-2" 7'-2" 2'-4" 2'-6" 2'-4" 2'-4" 2'-6" 2'-4" 8" 9" 8" 9" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 7-3/4" � Parking Police Station � 10-3/8" � Transit Station 3'-0" 2'-7" 3'-0" 2'-7" Recreation Center � � Riverwalk Center � 5'-1" Kingdom Park � 5'-1" Ice Arena 8'-5 1/2" 8'-5 1/2"

1/2" 1/2" 5" 5" 5'-0" 5'-0" 5'-6" 5'-6"

9" 9" 2'-0" 2'-0"

SIGN TYPE A3b Secondary Vehicular Directional-3 message panels Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 28 Sign Type A3c, Breckenridge Town Limit

5'-0"

2-1/4" 4"

2-5/8"

7-5/8"

1-3/4" 4-1/8"

3-5/8" 2-3/4" 2-3/8" Sign Type A3: Breckenridge Town Limit ID, Side A Scale: 1’=1’-0”

7-3/8" 7'-2" 2'-4" 2'-6" 2'-4" 8" 4-7/8" 9" 2-1/2" 2-3/4" 2-1/2" 2-1/2"

8-3/4"

3'-0" 2'-7" 7-1/2" 5'-1" 8'-5 1/2" Sign Type A3: Breckenridge Town Limit ID, Side B Scale: 1’=1’-0” 1/2" 5" 5'-0" 5'-6"

9" 2'-0"

SIGN TYPE A3c-Side A Breckenridge Town Limit ID Scale: 1/2”=1’-0” 5'-0"

2-1/4" 4"

2-5/8"

7-5/8"

1-3/4" 4-1/8"

3-5/8" 2-3/4" Town of Breckenridge Signage Standards Manual 2-3/8" 29 Sign TypeType A3: A3c, Breckenridge Breckenridge Town Town Limit ID,Limit Side A Scale: 1’=1’-0”

7-3/8"

4-7/8"

2-3/4"

8-3/4"

7-1/2"

Sign Type A3: Breckenridge Town Limit ID, Side B Scale: 1’=1’-0”

7'-2"

8'-5 1/2"

SIGN TYPE A3c-Side B Breckenridge Town Limit ID Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 30 Sign Type A4a, Tertiary Vehicular Directional

DESCRIPTION: The Tertiary Vehicular Sign Message Panels: Removable 1/4” individual Directional is a smaller-scale single-posted multi- aluminum panel. Message background: V-3. use directional sign. The sign takes design cues Text, arrows and logo: V-1. Secure panels to from the victorian architecture of the town and background with exposed fasteners as specified. the rustic mining history of the region. Post Bases: 1/4” thick fabricated corten steel. CONTENT GUIDELINES: Sign is single-sided with copy and corresponding pictograms. Sign Cap & Brackets: Fabricated aluminum, powder coated P-2 to match corten steel. TYPEFACE: Highway Gothic, Series C. Sunburst: 1/4” thick aluminum, powder coated P-2 to match corten steel. CONSTRUCTION: Post and panel with penofin treated rough sawn cedar wood, powder coated -Footing: Break-away post base (see detail). metal and corrugated aluminum. High Intensity Reflective vinyl message panels. LOCATION: See Town Sign Location Map, Phase I. Posts/Structure: 9” square penofin treated rough sawn cedar wood posts with chamfer edges. Stain NOTES: Refer to sign fabricator shop drawings color: S-1, to be determined. for all construction details and additional information.

8 3/8"

5" Recreation Center 2'-9" � 6 -1/2"

8’-6"

9"

9-1/2" 2'-0"

SIGN TYPE A4a (Destination Entrance) Tertiary Vehicular Directional Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 31 Sign Type A4b, Tertiary Vehicular Directional, continued:

Sign Type A4b only:

Sign Cap: Notch sign cap for insertion and removal of double sided changeable message system.

North North Gold Gondola Gondola Rush Lot Lot Lot $ LOT FULL FREE

Layout 1, Side A Layout 1, Side B Layout 2, Side A

Additional Changeable Sign Panels 8 3/8"

5" Gold Rush 2'-9"

Lot 6 -1/2" LOT FULL

8’-6”

9"

9-1/2" 2'-0"

SIGN TYPE A4b (Parking lot entrance) Tertiary Vehicular Directional Scale: 1/2”=1’-0”

Layout 2, Side B Town of Breckenridge Signage Standards Manual 32 Sign Type A4c, Tertiary Vehicular Directional, continued:

Sign Type A4c only:

Changeable Message Portable Sign:

Double-sided changeable message temporary directional sign.

Notch sign cap for insertion and removal of double sided changeable message system.

Sign Base is heavily weighted for stability.

Gondola Parking FULL Skier Parking�

2'-9" 3"

SIGN TYPE A4c (Mobile directional) Tertiary Vehicular Directional Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 33 Sign Type A5, Single-post Vehicular Directional

DESCRIPTION: The Main Street Vehicular treated rough sawn cedar wood, painted metal and Directional provides vehicular direction for corrugated aluminum. White on Brown Reflective destinations off Main Street and other areas vinyl. where a double-posted sign is too wide. The sign takes design cues from the victorian architecture Post/Structure: 7” square penofin treated rough of the town and the rustic mining history of the sawn cedar wood posts with chamfered edges. region. Sign Panels: 3/4” thick fabricated aluminum CONTENT GUIDELINES: Sign is double-sided directional panels. Trim and returns powder with copy and corresponding arrows. coated: P-4. Message background: V-3. Arrows and message: V-1. Secure to “c” channel (powder TYPEFACE: Highway Gothic-Series C coated: P-1) with exposed blackened tamper- proof acorn nut fasteners. CONSTRUCTION: Post and panel with penofin Post Base: 1/4” thick fabricated corten steel. 4'-9" 7 1/2" 6" 3'-4" Sign Cap: Fabricated aluminum, powder coated: P-2. 6 1/2" � Court House 3" Footing: Break-away post base (see detail). 6 1/2" � Carter Museum 3" LOCATION: See Town Sign Location Map, � 6 1/2" Welcome Center 4” Phase I. 3" � 6 1/2" Ice Rink NOTES: Refer to sign fabricator shop drawings for all construction details and additional information.

7’-3” 10’-8”

7"

2'-0"

SIGN TYPE A5 Vehicular Directional Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 34 Sign Type A5, Vehicular Directional, continued:

3/4" 3/4" 3/4" 3/4" 3/4" 3/4"

2"

3/4"

4" 5"

Welcome Center 3/4"

SIGN TYPE A5 Vehicular Directional Scale: 1 1/2”= 1’

SIGN TYPE A5 Vehicular Directional (shown with 3 message panels) Scale: N.T.S. Town of Breckenridge Signage Standards Manual 35 Sign Type A6, Historic District ID

DESCRIPTION: The Historic District sign CONSTRUCTION: Cast bronze plaque fastened welcomes visitors to the historic district of the to standard 3” dia. black posts. Standard black Town of Breckenridge while entering Main Street. cast metal or cast resign Light Post base to match The sign takes design cues from historic cast existing town standard. metal plaques. LOCATION: See Town Sign Location Map, CONTENT GUIDELINES: The Town of Phase I. Breckenridge logo type occurs as shown. Sign is single-sided (message reads on sign facing road Footing: Break-away post base (see detail). only). NOTES: Refer to sign fabricator shop drawings TYPEFACE: Birch and Champers. for all construction details and additional information. This design and type of sign will only occur as “book ends” on either end of Main Street. See location plan. No such sign design shall occur elsewhere within the town.

g 

g 

g 

SIGN TYPE A6 Historic District ID Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 36 Sign Type A6, Historic District ID, continued:

Finish: Satin Bronze with Dark Oxidized background. Finish with Matthews Acrylic Paint graffiti coating. Leatherette Texture Background Texture: Leatherette.

1/2” Border: 1/2” raised flat edge.

Mounting: Fasten to 3” dia. post using 1” acorn nuts to match satin bronze finish.

Border Detail of sign panel and message

2-1/4" 1-3/4" 1-3/4" 1-1/4"

3"

4"

5"

1-3/4"

5"

5"

3"

SIGN TYPE A6 Historic District ID Scale: 1-1/2”=1’-0” Town of Breckenridge Signage Standards Manual 37 Sign Type A7a, Parking Lot Directional on Main Street

DESCRIPTION: The Main Street Parking Sign Frames: 1/2” fabricated aluminum bar stock. Lot Directional provides direction to lots off Powder coated color, P-4 Main Street. The sign takes design cues from the victorian architecture of the town. Post Bases & Post: Standard cast metal or cast resin Light Post base to match existing standards CONTENT GUIDELINES: Sign is double-sided of Breckenridge with a 3” dia. post. with parking symbol and arrow. Sphere Cap: Spun aluminum sphere powder TYPEFACE: N/A. coated P-1.

CONSTRUCTION: Powder coated aluminum LOCATION: See Town Sign Location Map, sign panel sandwiched between powder coated Phase I. aluminum frames and flag mounted to Town of Breckenridge standard light post. White and blue NOTES: Refer to sign fabricator shop drawings High Intensity Reflective vinyl symbol and arrow. for all construction details and additional information. Sign Panels: 1/8” fabricated metal-powder coated color P-2. Sandwich between sign frames.

1'-4"

1'-5 1/2"

� �

7'-0" 7'-0"

SIGN TYPE A7 Destination Directional on Main Street Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 38 Sign Type A7a, Destination Directional on Main Street, continued

 Permanently pin aluminum bar stock to sign panel.

Attach to light post with appropriate mounting hardware to withstand maximum torsion.

  

1'-4"

1 1/2"

7 3/8"

1'-4" 1'-5 1/2" 3/4" �

4 1/2"

3/4"

SIGN TYPE A7 Destination Directional on Main Street Scale: 3”=1’-0” SkiSki HillHill RoadRoad

Town of Breckenridge Signage Standards Manual 39 Sign Type A8, Vehicular Street ID (Main Street and Park Avenue)

2-1/2"

5'-2-1/2"

1'-0" 6" cap WashingtonWashington AveAve

12'-6"

Sign TypeSIGN A8 TYPE A8 Street Identification:Vehicular Street Main ID (Main Street Street) and Park Avenue Scale: 1/2”=1’-0” Scale: 1/2’=1’-0” Town of Breckenridge Signage Standards Manual 40 Sign Type A8, Vehicular Street ID (Main Street and Park Avenue), continued:

DESCRIPTION: The Street I.D. identifies street Secure to post cuff (powder coated: P-4) with names on Main Street and Park Avenue. The exposed blackened tamper-proof acorn nut design is intended to be visible and legible for fasteners. visitors and residents. LOCATION: See Town Sign Location Map, CONTENT GUIDELINES: Sign is double- Phase II. For use only on Main Street and Park sided with Street name in one of the two layouts Avenue. illustrated. NOTES: Refer to sign fabricator shop drawings TYPEFACE: Highway Gothic-Series C. for all construction details and additional information. CONSTRUCTION: All aluminum construction with border. All background and text are high intensity reflective vinyl. Mounted to existing Town of Breckenridge light post standard.

Sign Panels: 3/4” thick fabricated metal directional and arrow panels. Trim and returns powder coated: P-4. Message background: V-3. Arrows and message: V-1.

5'-1" 2-1/2" verify in-field 5'-0"

1" 2-1/2" 11" 6" cap Ave 2-1/2" Washington 1" Longer Name with Abbreviated Modifier

3/4" 3/4" 3/4"

Ski Hill Road

Shorter Name with Modifier Spelled-out

SIGN TYPE A8 Vehicular Street ID (Main Street & Park Avenue) Scale: 1”=1’-0” Sign Type A8 Street Identification: Main Street and Park Avenue Scale: 1’=1’-0” Town of Breckenridge Signage Standards Manual 41 Sign Type A9, Secondary Vehicular Street ID (Neighborhoods)

PLAN

SIGN TYPE A9 Secondary Vehicular Street ID Scale: 1/2”=1’-0” AVE

Town of Breckenridge Signage Standards Manual 42 Sign Type A9, Secondary Vehicular Street ID (Neighborhoods)

DESCRIPTION: The Secondary Vehicular powder coated: P-4. Message background: V-3. Directional identifies the visitor with direction. Arrows and message: V-1. The sign takes design cues from the victorian architecture of the town. Secure to post cuff (powder coated: P-4) with exposed blackened tamper-proof acorn nut CONTENT GUIDELINES: Sign is double- fasteners. sided with Street name in one of the two layouts illustrated. LOCATION: See Town Sign Location Map, Phase II. For use only on ancillary streets of Main TYPEFACE: Highway Gothic-Series C. Street and Park Avenue.

CONSTRUCTION: All aluminum construction NOTES: Refer to sign fabricator shop drawings with border. All background and text are high for all construction details and additional intensity reflective vinyl. Mounted to existing information. Town of Breckenridge light post standard.

Sign Panels: 3/4” thick fabricated metal directional and arrow panels. Trim and returns

Varies 5/8" 1-1/2" 3'-6"

5/8" 1-3/4" 7-1/4" 4" Ave 1-3/4" Washington 5/8" Longer Name with Abbreviated Modifier

Ski Hill Road

Shorter Name with Modifier Spelled-out

SIGN TYPE A9 Secondary Vehicular Street ID Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 43 Sign Type A10, Vehicular Regulatory Signs

DESCRIPTION: Vehicular Regulatory Signs Post Bases & Post: Standard cast metal or cast provide vehicular control and information. resin Light Post base to match existing standards of Breckenridge with a 3” dia. post. CONTENT GUIDELINES: Sign is single-sided with standard DOT reflective Regulatory sign Sphere Cap: Spun aluminum sphere powder panel. coated P-1.

TYPEFACE: Highway Gothic-Series C. LOCATION: See Town Sign Location Map, Phase II. CONSTRUCTION: High intensity reflective on aluminum sign panel mounted to powder coated NOTES: Refer to sign fabricator shop drawings black aluminum frame (attached with VHB tape for all construction details and additional and exposed acorn nut fasteners) and mounted to information. post with exposed fasteners. All sign designs and colors must comply with Sign Panels: Standard regulatory signs set into the Manual on Uniform Traffic Control Devices aluminum frame. (MUTCD) requirements.

Sign Frame: Painted black L-extrusion to allow for sign panel to be inset at least 3/8” into frame. Back of frame is finished with an aluminum panel, powder coated: P-4.

SIGN TYPE A10 Vehicular Regulatory signs Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 44 Sign Type A10, Vehicular Regulatory Signs, continued

DESCRIPTION: Vehicular Regulatory Signs Sign Frame: Painted black L-extrusion to allow provide vehicular control and information. for sign panel to be inset at least 3/8” into frame. Back of frame is finished with an CONTENT GUIDELINES: Sign is single-sided aluminum panel, powder coated: P-4. with standard DOT reflective Regulatory sign panel. Post Bases & Post: Standard cast metal or cast resin Light Post base to match existing standards TYPEFACE: Highway Gothic-Series C. of Breckenridge with a 3” dia. post.

CONSTRUCTION: High intensity reflective on Sphere Cap: Spun aluminum sphere powder aluminum sign panel mounted to powder coated coated P-1. black aluminum frame (attached with VHB tape and exposed acorn nut fasteners) and mounted to LOCATION: See Town Sign Location Map, post with exposed fasteners. Phase II.

Sign Panels: Standard regulatory signs set into NOTES: Refer to sign fabricator shop drawings aluminum frame. for all construction details and additional information.

All sign designs and colors must comply with the Manual on Uniform Traffic Control Devices (MUTCD) requirements.

SIGN TYPE A10 Vehicular Regulatory signs Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 45 Sign Type A10, Vehicular Regulatory Signs, continued:

Aluminum sign panel to be pin mounted to L-extrusion.   



5/8” acorn nuts to have a dark oxidized finish. Town of Breckenridge Signage Standards Manual 46 Sign Type A11, Banner Armature

DESCRIPTION: Post and armature for Town of Post Bases & Post: 3” dia. cast metal Light Post Breckenridge banners. to match existing Town Of Breckenridge standard post design. CONTENT GUIDELINES: Sign allows for double-sided banners. Sphere Cap: Spun aluminum sphere powder coated P-1. TYPEFACE: N/A. Banners shown are for position and illustrative CONSTRUCTION: Powder coated 1” Aluminum purposes only. Actual banners to be provided by bar stock, color: P-4, with a welded 1/8” The Town of Breckenridge. continuous aluminum tab to allow for a banner to be attached with exposed fasteners. Attach to post LOCATION: See Town Sign Location Map, with appropriate mounting hardware to withstand Phase II. maximum torsion. NOTES: Refer to sign fabricator shop drawings for all construction details and additional information.

g 

g 

3TANDARDCASTMETAL ORCASTRESIN ,IGHT0OSTBASE MATCHEXISTING

SIGN TYPE A11 Banner Armature Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 47 Sign Type A11, Banner Armature, continued:

 g 

  



g 







1” dark oxidized acorn nuts.



SIGN TYPE A11 Banner Armature Scale: 1/4” scale Town of Breckenridge Signage Standards Manual 48 Sign Type A11, Banner Armature, continued:

Banners are to be printed on the highest qual- ity fabric with grommet holes corresponding to the holes on the banner armature. The banners shown above are for illustrative purposes only. Town of Breckenridge Signage Standards Manual 49 Sign Type B1, Primary Pedestrian Directional: with Town Map

DESCRIPTION: The Primary Pedestrian Posts/Structure: 8” square penofin treated rough Directional sign directs visitors to major sawn cedar wood posts with chamfer edges. destinations with a town orientation map. Length T.B.D. by footing depth. The sign takes design cues from the victorian architecture of the town and the rustic mining Directional Sign Blades: 1/2” smooth Brazilian history of the region. Redwood (Ipe) blades to resemble skies and torsion flag channel with exposed fasteners. 3M CONTENT GUIDELINES: Sign is double- die-cut vinyl messages, color: V-2. sided. 3 directional messages per side. Sign Case. 4’-7 1/4” X 2’-9” Rigid aluminum TYPEFACE: Champers. frame with eased edges powder coated P-2 to match corten steel. Corrugated aluminum inset in sign CONSTRUCTION: Post and sign blades are case with map panel with exposed dark oxidized acorn penofin treated rough sawn cedar wood, painted fasteners. Sunburst: 1/4” thick aluminum, powder metal and smooth treated wood directional sign coated P-2 to match corten steel. Clear Lexan blades. Sign case has a rigid aluminum frame door window. with a locking glass door. Torch cut information symbol as a cap. Post Bases: 1/4” thick fabricated corten steel.

g  Post Cap: Fabricated aluminum, powder coated P-2 to match corten steel.

Footing: Break-away post base (see detail).

LOCATION: See Town Sign Location Map, Phase II.

NOTES: Refer to sign fabricator shop drawings for all construction details and additional information.

g  g  g 

g 

SIGN TYPE B1 Pedestrian Directional: with Town Map Scale: 3/8”=1’-0” Town of Breckenridge Signage Standards Manual 50 Sign Type B1, Primary Pedestrian Directional: with Town Map, continued:

g  Torch cut steel Information Symbol welded to a post cap powder coated, P-4. g 

 



Sign Blades are mounted to an aluminum channel powder coated P-2 to match corten steel. The exposed fasteners are to resemble 1” half round rivets.

 g   





g  





 Brazilian Redwood sign blades are to have a heavy coat of polyurethane to prevent the wood from turning grey and decreasing LRV levels between copy and background.

SIGN TYPE B1 Pedestrian Directional Details Scale: 1”=1’-0” Town of Breckenridge Signage Standards Manual 51 Sign Type B1, Primary Pedestrian Directional: with Town Map, continued:

 g   





g  g 

g 

g  

Sign case is to have a rigid aluminum frame with eased edges, powder coated P-2. The sign cap with sunburst is to be powder coated P-2. Clear Lexan door will have locking capabilities with key access. SIGN TYPE B1 Pedestrian Directional: with Town Map Scale: 1-1/2”=1’-0” Town of Breckenridge Signage Standards Manual 52 Sign Type B2a, Secondary Pedestrian Directional: Main Street

DESCRIPTION: The Secondary Pedestrian Sign Case: Rigid aluminum frame with eased Directional provides visitors a town map and edges powder coated P-2 to match corten steel. directional information on Main Street. The sign Corrugated aluminum inset in sign case with map takes design cues from the victorian architecture panel with exposed dark oxidized acorn fasteners. of the town and the rustic mining history of the Sunburst: 1/4” thick aluminum, powder coated P- region. 2 to match corten steel. Clear Lexan door window.

CONTENT GUIDELINES: Sign is single-sided. LOCATION: See Town Sign Location Map, Phase II. TYPEFACE: Champers. NOTES: Refer to sign fabricator shop drawings CONSTRUCTION: Standard Light Post to for all construction details and additional match existing Breckenridge standards. Sign case information. has a rigid aluminum frame with a locking glass door and optional changeable aluminum message panels within.

g 

SIGN TYPE B2a Secondary Pedestrian Directional: Main Street Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 53 Sign Type B2b, Secondary Pedestrian Directional: RiverWalk

DESCRIPTION: Same as Pedestrian Directional Sign Case: Rigid aluminum frame with eased on Main Street, except freestanding on River walk. edges powder coated P-2 to match corten steel. Corrugated aluminum inset in sign case with map CONTENT GUIDELINES: Sign is single-sided. panel with exposed dark oxidized acorn fasteners. Sunburst: 1/4” thick aluminum, powder coated P- TYPEFACE: Champers. 2 to match corten steel. Clear Lexan door window.

CONSTRUCTION: Post and sign case with LOCATION: See Town Sign Location Map, penofin treated rough sawn cedar wood. Sign case Phase II. has a rigid aluminum frame with a locking glass door and changeable optional aluminum message NOTES: Refer to sign fabricator shop drawings panels within. for all construction details and additional information. Posts/Structure: 6” square penofin treated rough sawn cedar wood posts with chamfer edges. Length T.B.D. by footing depth.

g  g 

SIGN TYPE B2a Secondary Pedestrian Directional: RiverWalk Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 54 Sign Type B2a and B2b, Secondary Pedestrian Directional: Map

  



  Rigid aluminum frame with eased edges powder coated P-2 to match corten steel. Corrugated aluminum inset in sign case with map panel with exposed dark oxidized acorn fasteners. Sunburst: 1/4” thick aluminum, powder coated P-2 to match corten steel. g  Clear Lexan hinge door with locking key hole. Allow a 1/2” recess for map. Map is to be a 4-color anti-graffiti high pressure laminate or porcelain enamel with exposed dark oxidized acorn fasteners. In most cases there will be flexible aluminum sign panels with exposed dark oxidized  acorn fasteners. Copy will be die-cut vinyl surface applied, color V-2. Natural satin g  g  corrugated aluminum will be inset behind the map and sign panels.

In some instances there will be sign cases with no flexible sign panels g  and therefore the height of the sign will change. SEE DETAIL FOR A COMPREHENSIVE MOUNTING DETAIL OF THE SIGN IN RELATIONSHIP TO A POST.

!,4%2.!4%.O$IRECTIONAL-ESSAGES

g 



SIGN TYPE B2a Secondary Pedestrian Directional: Map Scale: 1”=1’-0”, 1/4” scale Town of Breckenridge Signage Standards Manual 55 Sign Type B3, Bus Route Map

DESCRIPTION: The Bus Route Map identifies high resolution digital print on white the bus stop and presents a Route Map and reflective vinyl. Schedule. The sign takes design cues from the victorian architecture of the town. Note: A future electronic message board will be inset into the sign (with a smokey gray CONTENT GUIDELINES: Sign is double- clear acrylic face) with the appropriate sided. power supplied to the sign. A hinged fully clear lexan door will house a Route Map TYPEFACE: Various. and Schedule holder (provided by the Town). CONSTRUCTION: Aluminum sign cabinets with painted black returns and backside. Standard Post Bases & Post: 3” dia. cast metal Light Post Light Post to match existing Breckenridge to match existing Town Of Breckenridge standard standard design. post design.

Sign Case: Rigid aluminum frame with eased LOCATION: See Town Sign Location Map, edges powder coated P-4. Phase II.

Bus Stop: Dimensional fabricated aluminum NOTES: Refer to sign fabricator shop drawings “disc” with 3M die-cut vinyl surface for all construction details and additional applied faces. Alternate: Exterior grade information.

F GSFF S JE

3IGNANDCASEARE NON ILLUMINATED &UTURE'LOBAL POSITIONING 2/54%-!0 ELECTRONIC 3#(%$5,% READER

vXv  vXv 2OUTE-AP 3CHEDULE (OLDER g  (OLDER

&ABRICATEDMETAL CASEWITHHINGED 3TANDARDCASTMETAL TEMPEREDGLASS ORCASTRESIN DOOR2OUTEMAP ,IGHT0OSTBASE AND3CHEDULE MATCHEXISTING HOLDERSANDINSERTS BY4OWN

SIGN TYPE B3 Bus Route Map Scale: 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 56 Sign Type B3, Bus Route Map, continued:

g   g 

G JE F SFF S  g  g  g 

   



 2/54%-!0 3#(%$5,%

&UTURE 'LOBAL ,%$ 5NIT !REA

g 

g 

g 



g  SIGN TYPE B3 Bus Route Map Scale: 1 1/2”=1’-0” Town of Breckenridge Signage Standards Manual 57 Sign Type B3, Bus Route Map, continued:

F GSFF S JE

"RECKENRIDGE"US3TOP)DENTITY $ETAIL&REE2IDE Exterior grade digital prints .OTTO3CALE or equal to be used.

35--)434!'%

F GSFF S JE

"RECKENRIDGE"US3TOP)DENTITY $ETAIL3UMMIT3TAGE .OTTO3CALE Town of Breckenridge Signage Standards Manual 58 Sign Type B3, Bus Route Map, detail:

Sign cabinets are to conceal the 3” diameter post in a notch and then covered with a .090” aluminum sheet painted black. Countersink screws with painted heads.

SIGN TYPE B3 Bus Route Map Scale: 1 1/2”=1’-0”