Insulated Panel Systems Middle East, Africa, Turkey & Central Asia

Canberra MRT Station, Sembawang, Case Study 2 Case Study Canberra MRT Station Canberra MRT Station Case Study 3

The Project

The Canberra station (NS12) is an elevated Mass Rapid Transit (MRT) station on the North South Line located along Canberra Link in Sembawang, Singapore. The station will be linked to Canberra Plaza via an elevated sheltered footbridge built across Canberra Link. It is estimated that approximately 17,000 households will benefit from the station due to the upcoming Aesthetics Housing and Development Board (HDB) public housing developments, private condominiums as well as landed properties (Sembawang Springs Estate) located near the station. RSP Architects approached Kingspan to design and develop an aesthetic and functional roof system for the station.

Sector Public Transport and Infrastructure

Location Singapore

Client Land Transport Authority (LTA)

Architects RSP Architects, Singapore

Main Contractor China State Construction Engineering Corporation (Singapore)

Product and System KingZip Linea 400 1.2mm thk Aluminium, 2 coat PVDF painted, precurved sheets: 8,000m2 Kingspan WA200 Structural Liner with in 0.47mm thick GI steel: 8,000m2 Canberra MRT Station 5

“KingZip Linea with its 65mm tall ribs and The Design manufactured from Aluminium Alloy Grade 3004 is certified for use down to a 1.5 degree incline had adequate flexibility to achieve the required curvatures The Architect’s design brief and specifications required the roof covering to be in a single length sheet, without end laps. Thermal transmittance values and acoustic performance of the roof relating to airborne sound transmission and rain impact of the barrel vault roof design of the project.“ were also stipulated. The project specification required Thermal Transmittance Value (U value) no higher than 0.5W/m2K and a Sound Transmission Class (STC) of at least 38dB. Kingspan was able to exceed both these requirements with our proposed Chong Park Cheong roof build-up. In addition to the acoustic and thermal performance requirements, as the structure being a public transport General Manager - South East Asia facility, the lining material had to meet Class O of the Building Standards, and must pass BS476 Part 6 & 7. The KingZip Linea Kingspan Insulated Panels roof layer and the steel decking layer meet these requirements exactly and is also accredited Class 1 Roof Panel as per FM Approvals Standard FM4471.

Build Ease Fire 6 Case Study Canberra MRT Station Canberra MRT Station Case Study 7

The Construction

Due to the fact that the station was being built on a live and operational track, LTA and SMRT implemented several measures to improve safety such as limiting major works to non-service hours, sheltering the tracks with a temporary enclosure during the construction of the roof and creating a full-scale mock-up of the station structure and roof to determine the safest process of construction. In order to meet the safety requirements, the production of KingZip Linea Aluminium Standing Seam roofing was carried out on-site after service hours of the live MRT track. Kingspan portable rollfromers and curving equipment were fitted into shipping containers and mounted on a Kingspan trailer which allowed onsite manufacturing and smooth curving of KingZip to the required radii. Manufactured KingZip Linea sheets were hoisted to the roof at early hours of the morning and late evenings. This process eliminated the logistical burden of transporting 45 tons of aluminium roofing sheets to the site by long trailers. Contact details

Middle East, Africa, Americas Australia Turkey & Central Asia Morin Corporation Kingspan Insulated Panels Australia Kingspan Insulated Panels 685 Middle Street | Bristol CT 38-52 Dunheved Circuit Manufacturing LLC 06010 | U.S.A. St Marys | NSW 2760 PO Box 60493 Dubai Investment Park Gate 1 T: +1 (860) 584-0900 T: +61 (02) 8889 3000 Dubai l UAE E: [email protected] E: [email protected] www.kingspanpanels.com www.kingspanpanels.com.au T: +971 4 8854232 E: [email protected] www.kingspanpanels.ae South East Asia India

Kingspan Insulated Panels Pty Limited Kingspan Jindal Pvt. Ltd. UK & Europe 1 Commonwealth Lane #07-26 Old Manesar Road | Narsinghpur Singapore 149544 Gurgaon - 122001 | Haryana | India Kingspan Limited Greenfi eld Business Park 2 T: +65 6264 5942 T: +91 124 4393 200 Bagillt Road | Holywell E: [email protected] E: [email protected] CH8 7GJ | UK www.kingspanpanels.sg www.kingspanjindal.com

T: +44 (0) 1352 716 100 E: [email protected] www.kingspanpanels.co.uk

For the product off ering in other markets please contact your local sales representative or visit www.kingspanpanels.com

Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only and Kingspan Limited and its subsidiaries accept no liability in respect thereof.

07/2020