The CU 2-D-MAX-DOAS Instrument – Part 2: Raman Scattering Probability Measurements and Retrieval of Aerosol Optical Properties

Total Page:16

File Type:pdf, Size:1020Kb

The CU 2-D-MAX-DOAS Instrument – Part 2: Raman Scattering Probability Measurements and Retrieval of Aerosol Optical Properties Atmos. Meas. Tech., 9, 3893–3910, 2016 www.atmos-meas-tech.net/9/3893/2016/ doi:10.5194/amt-9-3893-2016 © Author(s) 2016. CC Attribution 3.0 License. The CU 2-D-MAX-DOAS instrument – Part 2: Raman scattering probability measurements and retrieval of aerosol optical properties Ivan Ortega1,2, Sean Coburn1,2, Larry K. Berg3, Kathy Lantz2,4, Joseph Michalsky2,4, Richard A. Ferrare5, Johnathan W. Hair5, Chris A. Hostetler5, and Rainer Volkamer1,2 1Department of Chemistry and Biochemistry, University of Colorado, Boulder, CO, USA 2Cooperative Institute for Research in Environmental Sciences (CIRES), Boulder, CO, USA 3Pacific Northwest National Laboratory, Richland, WA, USA 4Global Monitoring Division, Earth System Research Laboratory, NOAA, Boulder, CO, USA 5NASA Langley Research Center, Hampton, VA, USA Correspondence to: Rainer Volkamer ([email protected]) Received: 8 December 2015 – Published in Atmos. Meas. Tech. Discuss.: 18 January 2016 Revised: 12 July 2016 – Accepted: 13 July 2016 – Published: 23 August 2016 Abstract. The multiannual global mean of aerosol optical retrievals of AOD430 and g with data from a co-located depth at 550 nm (AOD550/ over land is ∼ 0.19, and that over CIMEL sun photometer, Multi-Filter Rotating Shadowband oceans is ∼ 0.13. About 45 % of the Earth surface shows Radiometer (MFRSR), and an airborne High Spectral AOD550 smaller than 0.1. There is a need for measurement Resolution Lidar (HSRL-2). The average difference (rela- techniques that are optimized to measure aerosol optical tive to DOAS) for AOD430 is C0:012 ± 0:023 (CIMEL), properties under low AOD conditions. We present an −0:012 ± 0:024 (MFRSR), −0:011 ± 0:014 (HSRL- inherently calibrated retrieval (i.e., no need for radiance 2), and C0:023 ± 0:013 (CIMELAOD − MFRSRAOD/ calibration) to simultaneously measure AOD and the aerosol and yields the following expressions for correla- phase function parameter, g, based on measurements of tions between different instruments: DOASAOD D azimuth distributions of the Raman scattering probability −.0:019 ± 0:006/ C .1:03 ± 0:02/× CIMELAOD 2 (RSP), the near-absolute rotational Raman scattering (RRS) (R D 0:98), DOASAOD D −.0:006 ± 0:005/ C .1:08 ± 2 intensity. We employ radiative transfer model simulations 0:02/× MFRSRAOD (R D 0:98), and CIMELAOD D 2 to show that for solar azimuth RSP measurements at solar .0:013 ± 0:004/C.1:05 ± 0:01/× MFRSRAOD (R D 0:99). elevation and solar zenith angle (SZA) smaller than 80◦, The average g measured by DOAS on both days was RSP is insensitive to the vertical distribution of aerosols and 0:66 ± 0:03, with a difference of 0:014 ± 0:05 compared to maximally sensitive to changes in AOD and g under near- CIMEL. Active steps to minimize the error in the RSP help molecular scattering conditions. The University of Colorado to reduce the uncertainty in retrievals of AOD and g. As two-dimensional Multi-AXis Differential Optical Absorp- AOD decreases and SZA increases, the RSP signal-to-noise tion Spectroscopy (CU 2-D-MAX-DOAS) instrument was ratio increases. At AOD430 ∼ 0.4 and 0.10 the absolute deployed as part of the Two Column Aerosol Project (TCAP) AOD errors are ∼ 0.014 and 0.003 at 70◦ SZA and 0.02 at Cape Cod, MA, during the summer of 2012 to measure di- and 0.004 at 35◦ SZA. Inherently calibrated, precise AOD rect sun spectra and RSP from scattered light spectra at solar and g measurements are useful to better characterize the relative azimuth angles (SRAAs) between 5 and 170◦. Dur- aerosol direct effect in urban polluted and remote pristine ing two case study days with (1) high aerosol load (17 July, environments. 0.3 < AOD430 < 0.6) and (2) near-molecular scattering con- ditions (22 July, AOD430 < 0:13) we compare RSP-based Published by Copernicus Publications on behalf of the European Geosciences Union. 3894 I. Ortega et al.: The CU 2-D-MAX-DOAS instrument – Part 2 1 Introduction the zenith. Measurements at low EA have maximum sensitiv- ity in the lowermost part of the atmosphere. More recently, Atmospheric aerosol particles play a key role in the energy two-dimensional MAX-DOAS (2-D-MAX-DOAS) has been balance of Earth’s atmosphere (IPCC, 2013). The aerosol op- shown to be a promising technique to measure the trace gas tical depth (AOD), defined as a vertical integral of the aerosol variability around the measurement site from scattered light extinction coefficient from the Earth surface to the top of the spectra at different azimuth angles (AAs), defined relative atmosphere, is an important input to assessments of how the to north (Wang et al., 2014; Ortega et al., 2015). The Uni- atmospheric aerosol burden affects the budget of incoming versity of Colorado (CU) 2-D-MAX-DOAS instrument has solar radiation in global climate models (Hansen et al., 2002; demonstrated range-resolved measurements of NO2 and oxy- Chung et al., 2005; McComiskey et al., 2008). McComiskey genated hydrocarbons from azimuth scans at low EA. The et al. (2008) studied the sensitivity of aerosol direct radia- spatial scale probed by 2-D-MAX-DOAS closely resembles tive forcing using representative uncertainties in currently es- the grid-cell size of atmospheric models and satellite pixels tablished methods to measure aerosol optical properties. For and can be used to systematically characterize chemical gra- a typical AOD uncertainty of 0.01 (best case scenario ex- dients under inhomogeneous conditions (Ortega et al., 2015). pected for newly calibrated ground-based radiometric instru- In this paper we exploit solar azimuth scattered light and ment in the visible spectra range; Eck et al., 1999; Holben direct sun measurements to assess aerosol column prop- et al., 1998), the error in the aerosol direct forcing is about erties using solar almucantar measurements. The informa- 0.6 W m−2 (top of the atmosphere) and 1.3 W m−2 (surface) tion content regarding aerosol properties using this geome- for a solar zenith angle (SZA) of 45◦ (McComiskey et al., try has been discussed in detail for radiance measurements 2008). The multiannual global mean AOD550 estimated from with single wavelength channel detectors elsewhere (Box satellites finds that about 28 and 43 % of the land surface and and Deepak, 1979; Nakajima et al., 1983; Kaufman et al., 15 and 46 % of the ocean surface have AOD ≤ 0.05 and ≤ 0.1 1994; Bohren and Huffman, 1998; Dubovik et al., 2000). We (Remer et al., 2008); current ground-based networks capture use solar almucantar scans in combination with hyperspec- frequent AOD values below 0.15 (Holben et al., 2001; Au- tral measurements and describe a new retrieval scheme to es- gustine et al., 2008; Michalsky et al., 2010; Mao et al., 2014). timate AOD430 and aerosol phase functions (simplified by Low AOD conditions are projected to be more prevalent in g, Henyey–Greenstein (HG) approximation) based on quan- the future (Westervelt et al., 2015). Under these conditions, titative analysis of the rotational Raman scattering (RRS) measurements of AOD with higher accuracy and precision by atmospheric molecules (Ring effect) (Grainger and Ring, are even more desirable. 1962; Chance and Spurr, 1997). RRS causes “filling-in” of Traditional AOD measurements often employ radiometric the solar Fraunhofer lines and has to be taken into account calibrated instruments, e.g., CIMEL sun photometer (Holben to accurately estimate absorption of trace gases using pas- et al., 1998) and Multifilter Rotating Shadowband Radiome- sive DOAS techniques (Platt and Stutz, 2008). Several stud- ter (MFRSR) (Harrison et al., 1994). In general, the retrieval ies have described the quantitative analysis of RRS and its of AOD is estimated based on the extinction of the direct effect in solar scattering UV–vis observations (Vountas et al., sun irradiance measurements. The quality of such measure- 1998, 2003; de Beek et al., 2001; Langford et al., 2007). The ments is improved under high AOD and cloud-free condi- quantitative analysis of RRS by DOAS was introduced by tions. In contrast, under molecular scattering conditions, i.e., Wagner et al. (2004, 2009a) with the so-called Raman scat- AOD430 < 0:13 (Rayleigh scattering extinction under over- tering probability (RSP) (the probability that a detected pho- head sun conditions), the measurements become subject to ton has undergone a rotational Raman scattering event). Un- higher relative uncertainties (Holben et al., 1998). Holben et der cloud-free conditions the AOD has a strong effect on the al. (1998) pointed out that the error in AOD by means of RSP, which further exhibits a high dependency on the so- solar sky brightness (scattering) in the solar aureole region lar relative azimuth angle (Wagner et al., 2009b, 2014). To may be lower than traditional direct sun extinction methods. the best of our knowledge, there has been no previous mea- However, to our knowledge, this has not previously been ex- surement of AOD and g using almucantar scans of RSP by ploited in measurements to date. MAX-DOAS. Multi-axis differential optical absorption spectroscopy (MAX-DOAS) can simultaneously retrieve trace gases and aerosol optical properties (Hönninger et al., 2004; Wagner et 2 Experimental al., 2004; Frieß et al., 2006; Clémer et al., 2010). The MAX- DOAS technique relies on spectrally resolved solar scattered 2.1 The Two-Column Aerosol Project (TCAP) field light measurements at several elevation angles (EAs), defined campaign between the horizon and zenith (Hönninger et al., 2004). The retrieval approach does not require radiometric calibration, The first phase of the Department of Energy (DOE) TCAP and the trace gases and aerosol optical properties are mea- field campaign took place at Cape Cod, MA, during the sum- sured relative to a reference spectrum, typically recorded in mer of 2012 (Berg et al., 2016).
Recommended publications
  • A Customized Stand-Alone Photometric Raman Sensor Applicable in Explosive Atmospheres: a Proof-Of-Concept Study
    J. Sens. Sens. Syst., 7, 543–549, 2018 https://doi.org/10.5194/jsss-7-543-2018 © Author(s) 2018. This work is distributed under the Creative Commons Attribution 4.0 License. A customized stand-alone photometric Raman sensor applicable in explosive atmospheres: a proof-of-concept study Marcel Nachtmann1, Shaun Paul Keck1, Frank Braun1, Hanns Simon Eckhardt2, Christoph Mattolat2, Norbert Gretz3, Stephan Scholl4, and Matthias Rädle1 1Institute for Process Control and Innovative Energy Conversion, Mannheim University of Applied Sciences, Mannheim, 68163, Germany 2tec5 AG, Oberursel/Ts, 61440, Germany 3Medical Research Center, Medical Faculty Mannheim, Heidelberg University, Mannheim, 68167, Germany 4Institute for Chemical and Thermal Process Engineering, Technical University Braunschweig, Braunschweig, 38106, Germany Correspondence: Matthias Rädle ([email protected]) Received: 29 March 2018 – Revised: 12 September 2018 – Accepted: 14 September 2018 – Published: 12 October 2018 Abstract. This paper presents an explosion-proof two-channel Raman photometer designed for chemical pro- cess monitoring in hazardous explosive atmospheres. Due to its design, alignment of components is simplified and economic in comparison to spectrometer systems. Raman spectrometers have the potential of becoming an increasingly important tool in process analysis technologies as part of molecular-specific concentration monitor- ing. However, in addition to the required laser power, which restricts use in potentially explosive atmospheres, the financial hurdle is also high. Within the scope of a proof of concept, it is shown that photometric measure- ments of Raman scattering are possible. The use of highly sensitive detectors allows the required excitation power to be reduced to levels compliant for operation in potentially explosive atmospheres.
    [Show full text]
  • Input-Output Transfer Function Analysis of a Photometer Circuit Based on an Operational Amplifier
    Sensors 2008, 8, 35-50 sensors ISSN 1424-8220 © 2008 by MDPI www.mdpi.org/sensors Input-output Transfer Function Analysis of a Photometer Circuit Based on an Operational Amplifier Wilmar Hernandez Department of Circuits and Systems in the EUIT de Telecomunicacion at the Universidad Politecnica de Madrid (UPM), Campus Sur UPM, Ctra. Valencia km 7, Madrid 28031, Spain Phone: +34913367830. Fax: +34913367829. E-mail: [email protected] Received: 22 December 2007 / Accepted: 7 January 2008 / Published: 9 January 2008 Abstract: In this paper an input-output transfer function analysis based on the frequency response of a photometer circuit based on operational amplifier (op amp) is carried out. Op amps are universally used in monitoring photodetectors and there are a variety of amplifier connections for this purpose. However, the electronic circuits that are usually used to carry out the signal treatment in photometer circuits introduce some limitations in the performance of the photometers that influence the selection of the op amps and other electronic devices. For example, the bandwidth, slew-rate, noise, input impedance and gain, among other characteristics of the op amp, are often the performance limiting factors of photometer circuits. For this reason, in this paper a comparative analysis between two photodiode amplifier circuits is carried out. One circuit is based on a conventional current- to-voltage converter connection and the other circuit is based on a robust current-to-voltage converter connection. The results are satisfactory and show that the photodiode amplifier performance can be improved by using robust control techniques. Keywords: photometer circuit, current-to-voltage converter connection, frequency response, robust control Sensors 2008, 8 36 1.
    [Show full text]
  • Photoelectric Spectrophotometry by the Null Method'
    . PHOTOELECTRIC SPECTROPHOTOMETRY BY THE NULL METHOD' By K. S. Gibson CONTENTS Page I. Introduction 325 II. Spectral transmission 329 1. Apparatus 329 2. Method 333 3 Errors and accuracy 337 III. Diffuse spectral reflection 348 IV. Other applications 350 V. Summary 352 I. INTRODUCTION Anyone who has had experience in trying to make spectro- photometric measurements of transmission or reflection in the blue and violet parts of the spectrum is well aware of the difficulty of obtaining reliable determinations in this region. Nearly all methods have relatively low sensitivity, or else are inaccurate for other reasons, from wave lengths 400 to 500 millimicrons (m/x). Radiometric methods, which are so suitable for infra-red work and which have been used also in the visible and even in the ultra- violet, are, nevertheless, not of the highest accuracy in these latter regions because of the relatively low radiant power of all sources used for this kind of work, the radiant power decreasing continuously with the wave length. It is very difficult to obtain accurate determinations below 500 m/x by the usual radiometric methods. Any visual method is limited in the blue and violet because of the combined low visibility of the human eye and the low radiant power of the sources used, except at the few wave lengths where monochromatic light of great intensity can be ob- tained, as from the mercury arc. The Hilger sector photometer method, which is the only photographic method of speed and reliability, also has its limitations for this region. Being such a 1 An abst-act of this paper was presented to the Optical Society of America at the Baltimore meet- ing, Dec, 27, 1918.
    [Show full text]
  • Application of Filter Photometers in the Production of Ethylene and Propylene
    Analytical Products Sales Engineering Application of Filter Photometers in the Production of Ethylene and Propylene SC7-66-403 Gary D. Brewer APPLICATION OF FILTER PHOTOMETERS IN THE PRODUCTION OF ETHYLENE AND PROPYLENE Gary D. Brewer Product Manager, Photometers ABB Inc. 843 N. Jefferson St. Lewisburg, WV 24901 KEYWORDS Photometer, Infrared Spectroscopy, IR, Near Infrared Spectroscopy, NIR, Ultraviolet Spectroscopy, UV, Ethylene, Propylene ABSTRACT There have been several successful applications of process filter photometers in ethylene plants throughout the world. The process of manufacturing ethylene is extremely fast; therefore, the continuous measurements provided by filter photometers allow for a fast response to process changes for better control and process optimization. The capability of the current generation of filter photometers to use several analytical wavelengths to compensate for spectral interferences have allowed their use in measurements that previously could not be done by photometers. The high reliability and simplicity of filter photometers make them a valuable tool in the process control of an olefins plant. Applications in the IR and NIR spectral regions in both the vapor and liquid phases will be discussed to demonstrate their capabilities and benefits in this manufacturing process. Applications that will be discussed include the measurement of acetylene and ethane at the acetylene converters and the measurement of methyl acetylene and propadiene (MAPD) at the MAPD converters can be measured on a single infrared photometer. Applications at the caustic wash tower and the measurement of carbon dioxide at the furnace decoke will also be discussed. INTRODUCTION Ethylene is one of the highest volume chemicals produced in the world.
    [Show full text]
  • Raman Spectroscopy Protocol
    raman-prtkl4.doc 1/15 10.07.07 Raman Spectroscopy Comparison of Infrared Spectra with those gathered by Raman Spectroscopy of selected substances Protocol June 9th and 11th 1999, August 19th and 20th 1999, February 28th and 29th 2000 Headed by: Dr. M. Musso Handed in by : Pierre Madl (Mat-#: 9521584) Maricela Yip (Mat-#: 9424495) Salzburg, August 28th 2000 raman-prtkl4.doc 2/15 10.07.07 Introduction When radiation passes through a transparent medium, the species present scatter a fraction of the beam in all directions. In 1928, the Indian physicist C.V.Raman discovered that the wavelength of a small fraction of the radiation scattered by certain molecules differ from that of the incident beam; furthermore, the shifts in wavelength depend upon the chemical structure of the molecules responsible for scattering. The theory of Raman scattering, which now is well understood, shows that the phenomenon results from the same type of quantized vibrational changes that are associated with infrared (IR) absorption. Thus, the difference in wavelength between the incident and scattered radiation corresponds to wavelengths in the mid-infrared region. Indeed, Raman scattering spectrum and infrared spectrum for a given species often resemble one another quite closely. There are, however, enough differences between the kinds of groups that are infrared active and those that are Raman active to make the techniques complementary rather than competitive. For some problems, the infrared method is the superior tool, for others, the Raman procedure offers more useful spectra. An important advantage of Raman spectra over infrared lies in the fact that water does not cause interference; indeed, Raman spectra can be obtained form aqueous solutions.
    [Show full text]
  • An Infrared Photon-Counting Photometer Based on the Edge-Illuminated Solid-State Photomultiplier
    An Infrared Photon-counting Photometer Based on the Edge-illuminated Solid-State Photomultiplier Dae-Sik Moon1234, Stephen S. Eikenberry54, and Giovanni G. Fazio6 1Division of Physics, Mathematics and Astronomy, Caltech, MC 103–33, Pasadena, CA 91125; 2Robert A. Millikan Fellow; 3Space Radiation Laboratory, Caltech, MC 220–47, Pasadena, CA 91125; 4Department of Astronomy, Cornell University, Ithaca, NY 14853; 5Department of Astronomy, University of Florida, Gainesville, FL 32611; 6Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA ABSTRACT We present the design, construction, and test observations of a new infrared (IR) photon-counting photometer for astronomy based on the edge-illuminated solid-state photomultiplier (EISSPM). The EISSPM has a photon- counting capability over the 0.4–28 µm range with a nanosecond-scale intrinsic detector time resolution. Its quantum efficiency (QE) peaks ≥ 30 % in the near-IR, which is much higher than the previous SSPM with back illumination. After characterizing the dark noise of the EISSPM at its operational temperature range, we develop an EISSPM-based IR photon-counting photometer for astronomical observations. This includes the design and construction of a full optical, cryo-mechanical, and electronics system as well as the software for operating the instrument on telescopes. We report the results of our test observations of the Crab Nebula pulsar using this new instrument on the Palomar Hale 5-m telescope with 10-µs time resolution. Keywords: infrared, instrumentation, detectors, photometers 1. INTRODUCTION A photon-counting capability with > 100 Hz sampling rate (and potentially up to ∼106 Hz sampling rate) has diverse interesting applications in modern astronomy, involving both observational and technological aspects.
    [Show full text]
  • Sphinx: the Solar Photometer in X-Rays
    Solar Phys DOI 10.1007/s11207-012-0201-8 SphinX: The Solar Photometer in X-Rays Szymon Gburek · Janusz Sylwester · Miroslaw Kowalinski · Jaroslaw Bakala · Zbigniew Kordylewski · Piotr Podgorski · Stefan Plocieniak · Marek Siarkowski · Barbara Sylwester · Witold Trzebinski · Sergey V. Kuzin · Andrey A. Pertsov · Yurij D. Kotov · Frantisek Farnik · Fabio Reale · Kenneth J.H. Phillips Received: 10 April 2012 / Accepted: 19 November 2012 © Springer Science+Business Media Dordrecht 2012 Abstract Solar Photometer in X-rays (SphinX) was a spectrophotometer developed to ob- serve the Sun in soft X-rays. The instrument observed in the energy range ≈ 1–15 keV with resolution ≈ 0.4 keV. SphinX was flown on the Russian CORONAS–PHOTON satellite placed inside the TESIS EUV and X telescope assembly. The spacecraft launch took place on 30 January 2009 at 13:30 UT at the Plesetsk Cosmodrome in Russia. The SphinX exper- iment mission began a couple of weeks later on 20 February 2009 when the first telemetry dumps were received. The mission ended nine months later on 29 November 2009 when data transmission was terminated. SphinX provided an excellent set of observations dur- ing very low solar activity. This was indeed the period in which solar activity dropped to the lowest level observed in X-rays ever. The SphinX instrument design, construction, and operation principle are described. Information on SphinX data repositories, dissemination methods, format, and calibration is given together with general recommendations for data users. Scientific research areas in which SphinX data find application are reviewed. S. Gburek () · J. Sylwester · M. Kowalinski · J. Bakala · Z. Kordylewski · P. Podgorski · S.
    [Show full text]
  • Euclid Near Infrared Spectro Photometer Instrument Concept and First Test Results at the End of Phase B
    CORE Metadata, citation and similar papers at core.ac.uk Provided by NORA - Norwegian Open Research Archives Euclid Near Infrared Spectro Photometer instrument concept and first test results at the end of phase B Thierry Maciaszek, Ctr. National d'Études Spatiales, and Observatoire Astronomique de Marseille-Provence (France); Anne Ealet, Ctr. de Physique des Particules de Marseille (France); Knud Jahnke, Max-Planck-Institut für Astronomie (Germany); Eric Prieto, Observatoire Astronomique de Marseille-Provence (France); Rémi Barbier, Institut de Physique Nucléaire de Lyon (France); Yannick Mellier, Institut d'Astrophysique de Paris (France), and Commissariat à l'Énergie Atomique (France); Anne Costille, Franck Ducret, Christophe Fabron, Jean-Luc Gimenez, Robert Grange, Laurent Martin, Christelle Rossin, Tony Pamplona, Pascal Vola, Observatoire Astronomique de Marseille-Provence (France); Jean Claude Clémens, Ctr de Physique des Particules de Marseille (France); Gérard Smadja, Institut de Physique Nucléaire de Lyon (France); Jérome Amiaux, Jean Christophe Barrière, Michel Berthe, Commissariat à l'Énergie Atomique (France); Adriano De Rosa, Enrico Franceschi, Gianluca Morgante, Massimo Trifoglio, Luca Valenziano INAF - IASF Bologna (Italy); Carlotta Bonoli, Favio Bortoletto, Maurizio D'Alessandro, INAF - Osservatorio Astronimico di Padova (Italy); Leonardo Corcione, Sebastiano Ligori, INAF - Osservatorio Astronomico di Torino (Italy); Bianca Garilli, Marco Riva, INAF - IASF Milano (Italy); Frank Grupp, Carolin Vogel, Max-Planck-Institut für extraterrestrische Physik (Germany); Felix Hormuth, Gregor Seidel, Stefanie Wachter, Max-Planck-Institut für Astronomie (Germany); Jose Javier. Diaz, Instituto de Astrofisica de Canarias (Spain); Ferran Grañena, Cristobal Padilla, Institut de Física d’Altes Energies (IFAE) (Spain); Rafael Toledo, Universidad Politécnica de Cartagena (Spain); Per B. Lilje, University of Oslo; Bjarte G.
    [Show full text]
  • Basics of Atomic Absorption Photometer
    (Hitachi High-Technologies) Technical Note: Atomic Absorption Photometer Basics of Atomic Absorption Photometer Hitachi High-Technologies Corporations Copyright© 2007, Hitachi High-Technologies Corporation 1 (Hitachi High-Technologies) Technical Note: Atomic Absorption Photometer 1. Atomic Absorption Photometer Q “What does an atomic absorption photometer measure?” A: It is a system which mainly measures the concentration of metallic elements (quantitative analysis). Q “What are metallic elements?” A: They are elements corresponding to metallic elementary substances. For example, calcium, which is an ingredient in our bones, or sodium and potassium, which are contained in alkali drinking water are metallic elements. The metallic elements which can be measured are shown in the following periodic table. z Sixty-nine elements can be analyzed. z The elements which can be measured are shaded. z The peripheral equipment which needs to be prepared varies by element. Please refer to the supplemental data for details. Q “What concentrations can it measure?” A: It can measure from ppm to ppb. Q “Just a moment. What are ppm and ppb?” A: These are units indicating concentration, similar to percent. The ‘m’ and ‘b’ in ppm and ppb stand for million and billion, respectively. That is, 1% means 1/100, ppm means 1/million and ppb means 1/billion. To illustrate simply, 1% would mean one person in 100 people, while 1 ppm would be one person in one million people. Do you understand? Please see the following concentration conversion table. Generally a measurement sample is a solution specimen. Solution concentration units 1% = 1/100 = 10-2 1 ppm = 1/1,000,000 = 10-6 = 0.0001% 1 ppm = 1 mg/L= 1 µg/mL 1 ppb = 0.001 ppm = 10-9 1 ppt = 0.001 ppb = 10-12 = 1/trillion 1 ppb = 1 µg/L =1 ng/mL 1 ppt = 1 ng/L =1 pg/mL 1 (Hitachi High-Technologies) Technical Note: Atomic Absorption Photometer 2.
    [Show full text]
  • Troubleshooting Guide for the Measurement of Nucleic Acids with Eppendorf Biophotometer® D30 and Eppendorf Biospectrometer®
    USERGUIDE No. 13 I May 2015 Troubleshooting Guide for the Measurement of Nucleic Acids with Eppendorf BioPhotometer® D30 and Eppendorf BioSpectrometer® Katrin Kaeppler-Hanno, Martin Armbrecht-Ihle, Ronja Kubasch, Eppendorf AG, Hamburg, Germany Introduction This Troubleshooting Guide will help you to achieve reliable results using devices of the Eppendorf photometer family (fig. 1) with focus on nucleic acid quantification. Therefore, the critical factors for attaining a precise measurement are summarized and recommendations are given on how to solve problems that might be encountered. Figure 1: Eppendorf BioPhotometer D30 – one member of the Eppendorf Photometer family USERGUIDE I No. 13 I Page 2 Fundamentals of photometric measurements - Lambert-Beer Law To calculate the concentration of the liquid sample in a cuvette, first the transmission (T) is measured by the I1 photometer, while calculating the ratio of outgoing (I1) and A T= —— I0 ingoing light (I0) (fig. 2). The negative common logarithm of the transmission is the absorbance (A) value. The measured absorbance in a photometer depends on the optical path B - logT= A length, the concentration and a sample specific factor, the absorbance coefficient. This dependency is also called the I0 I Lambert-Beer law: Lambert-Beer-Law. 1 C A = e x c x OL As shown in fig. 2D the concentration of the sample can be calculated via transforming the Lambert-Beer Law. Concentration: c=A/e*OL c= A*F This can be done very easily if you look on the physical D constants and parameters that are described in the Lam- OL bert-Beer Law. In table 1 all the important parameters Figure 2: and the corresponding SI-units are listed.
    [Show full text]
  • Aastheory.Pdf
    Principle of Atomic Absorption /Emission Spectroscopy 15.1 ATOMIC EMISSION-THE FLAME TEST When a small amount of a solution of a metal ion is placed in the flame of a Bunsen burner, the flame turns a color that is characteristic of the metal ion. A sodium solution gives a yellow color, a potassium solution results in a violet color, a copper solution gives a green color, etc. Such an experiment, called the flame test, has been used in conjunction with other tests in many qualitative analysis schemes for metal ions. Whatever color our eye perceives indicates what metal ion is present. When more than one metal ion is present, viewing the flame through a colored glass filter can help mask any interference. Figure 1 shows this experiment. The phenomenon just described is an "atomic emission" phenomenon. This statement may seem inappropriate, since it is a solution of metal ions (and not atoms) that is tested. The reason for calling it atomic emission lies in the process occurring in the flame. One of the steps of the process is an atomization step. That is, the flame converts the metal ions into atoms. When a solution of sodium chloride is placed in a flame, for example, the solvent evaporates, leaving behind solid crystalline sodium chloride. This evaporation is then followed by the dissociation of the sodium chloride crystals into individual ground state atoms -a process that is termed atomization. Thus sodium atoms are actually present in the flame at this point rather than sodium ions, and the process of light emission actually involves these atoms rather than the ions.
    [Show full text]
  • Brochure Photometer
    We bring quality to light. Photometers Radiometry vs. Photometry The CIE V () Function Visible light is only a small section of electro-magnetic radiation which produces a sensation of brightness and color in the human eye. Electromagnetic radiation is a form of energy. The spectrum of such radiation provides information on its energy composition. The entire spectrum of electro- magnetic radiation ranges from X-ray radiation at the high-energy, short-wave end to radio waves at the low-energy, long-wave end. Radiometry is the measure- ment of optical radiation, which is electromagnetic radiation within the frequency range between 3x1011 and 3x1016 Hz. This range corresponds to wavelengths between 0.01 and 1000 micrometers (mm), and includes the regions commonly called the ultraviolet (UV), the visible (VIS), and the infrared (IR). Two of the many typically encountered units are watt/m2 and photon/ sec-steradian. Photometry is the measurement of light, which is defined as electromagnetic radiation detectable by the human eye. It is thus restricted to the wavelength range from about 380 to 780 nanometers (nm; 1000 nm = 1 mm). Photometry is just like radiometry except that everything is weighted by the spectral response of the eye. Visual photometry uses the eye as a comparison detector, while physical photometry uses either optical radiation detectors constructed to mimic the spectral Electromagnetic radiation / VIS (visible radiation) response of the eye, or spectroradiometry coupled with appropriate calculations to do the eye response weight- ing. Typical photometric units include lumen, lux, and candela. 2 In order to have also a well defined photometer, an “artificial eye” has been constructed to simulate the light sensitivity of the human eye.
    [Show full text]