FLOW RATE INDICATOR WITH VERY LARGE DIGITS

Advantages Signal input • Robust IP66, IP67 (NEMA4X) field enclosure. Flow It is so rugged, you can even stand on it! • Ability to process all types of flowmeter signals: • Intrinsically Safe available - ATEX, IECEx, FM and Reed-switch, NAMUR, NPN/PNP pulse, Sine wave CSA approval for gas and dust applications. (coil), Active pulse signals, (0)4 - 20mA, 0 - 10V DC. • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost Applications and irritation. Know one, know them all! • The F-Series is your first and safest choice for field • Very diverse mounting possibilities: walls, pipes, mount indicators. Especially in harsh weather panels or directly onto outdoor sensors! conditions like rain, snow, salty atmosphers and temperatures between -40°C up to +80°C (-40°F up Features to 176°F) for safe and hazardous area applications! • Displays instantaneous flow rate and measuring • Flow measurement where a local flow rate unit. indication is required without re-transmission • Very large 26mm (1") digits. or totalizer functionality. Alternative advanced

DATASHEET INDICATOR RATE F010 - FLOW • Piegraph indication: ten segments. models: F012 - F013 - F014 - F016 or even more • Selectable on-screen engineering units; volumetric advanced F110 and higher or the D-Series DIN or mass. panel mount flow rate indicators. • Explosion/flame proof II 2 GD EEx d IIB T5. • Easy configuration with clear alphanumerical display and descriptions. • LED backlight option. • Loop or battery powered, 8 - 24V AC/DC or 115 - 230V AC power supply. • Sensor supply 3.2 / 8.2 / 12 / 24V DC. 1 General information Signal input Introduction The F010 accepts most pulse and analog input The F010 is a local indicator to display the actual signals for volumetric flow or mass flow flow rate. The measuring and time unit to be measurement. The input signal type can be displayed are simply selected through an alfa- selected by the user in the configuration menu numerical configuration menu. No adhesive labels without having to adjust any sensitive mechanical have to be put on the outside of the enclosure: a dip-switches, jumpers or trimmers. The analog weather proof and user friendly solution! input version is even available as 4 - 20mA input The configuration of K-factors or Span and number loop powered display. of decimals is done through software functions, without any sensitive dip-switches or trimmers. A Power supply wide selection of options further enhance this Several power supply options are available to models capabilities, including Intrinsic Safety for power the F010 and sensor. Most popular is our hazardous area applications. battery powered version with a long life lithium battery which will last up to five years. Display For analog sensors, a 4 - 20mA loop powered The display has very large 26mm (1”) digits which version is available as well. A real sensor supply is can be set to show the flow rate and the offered with the 24V AC/DC or 115 - 230V AC power measuring and time units. As the F010 has been supply option. designed for field mounted applications, a smart display update function has been incorporated. Hazardous area Related to the lower temperatures, the update For hazardous area applications, this model has frequency of the LCD is tuned automatically to been ATEX, IECEx, FM and CSA certified achieve a readable display even at -40°C / -40°F. Intrinsically Safe for gas and dust applications, with an allowed operational temperature of Backlight -40°C to +70°C (-40°F to +158°F). A flame proof For those applications where readability during enclosure with ATEX certification offers the day and night is an issue, a bi-color backlight is rating II 2 GD EEx d IIB T5. available. The background color can be set to green or amber and the intensity can be adjusted Enclosures from the keyboard. The display is a transflective Various types of enclosures can be selected, all type, which means that a high contrast reading is ATEX, IECEx, FM and CSA approved. As standard guaranteed in full sunlight as well as during the the F010 is supplied in an GRP panel mount night. This backlight option is also available enclosure, which can be converted to an IP67 / Intrinsically Safe. NEMA 4X GRP field mount enclosure by the addition of a back case. Most popular is our Configuration aluminum field mount enclosure with IP67 / NEMA All configuration settings are accessed via a 4X rating. Both European or U.S. cable gland entry simple operator menu which can be pass-code threads are available. protected. Each setting is clearly indicated with an alphanumerical description, which avoids Overview application F010 confusing abbreviations and baffling codes. Once familiar with one F-series product, you will be able to program all models in the series without a manual. All settings are safely stored in EEPROM memory in the event of sudden power failure. Flowmeter input

2 F010 Dimensions enclosures Terminal connections power supply Aluminum & GRP panel mount enclosure PB/PC - PD - PL - PX

FLOWMETER INPUT POWER SUPPLY BACKLIGHT 31 mm 29 mm (1.22") (1.14") 130 mm (5.12")

115 (4.53") 1 2 3 456 9 10

P: coil PD: 16 - 30V DC ZB: 20 - 30V DC

120 mm (4.72") + + + 98 (3.86")

P: reed switch / NPN Sensor supply: For pulse input + (type P): 8.2V DC HB & HC enclosures panel cut-out P: active signal + Aluminum & GRP field / wall mount enclosures P: PNP

130 mm (5.12") Ø 7mm (0.27") Ø 7mm (0.27") - +

P: namur -

A: (0)4 - 20mA For analog input (type A): voltage as 120 mm (4.72") I+ connected to terminal 5. 60 mm (2.36") U: 0 - 10V 75 mm (2.95") 112 mm (4.40") For analog input (type U): voltage as U+ connected to terminal 5. Aluminum GRP A - PL: 4 - 20mA PL: input loop powered. 30mm 30mm I+

22,50 mm HD PX: 8 - 30V DC

PG9 M20 x 1,5 PG9 +

30mm 30mm 30mm 30mm PB / PC: battery powered (PX is also available: if an external supply is connected, the battery supply will be switched off / on automatically.) 22,50 mm 22,50 mm HM HE

M16 x 1,5 M20 x 1,5 M16 x 1,5 Ø16Ø20 Ø16 Terminal connections power supply PF - PM

22,50 mm HN HF 22,50 mm ( 0.9")

7 M20 x 1,5 Ø22 ( /8")

25mm 25mm 25mm 25mm POWER SUPPLY FLOWMETER INPUT 22,50 mm 22,50 mm HO HG

M20 x 1,5 M20 x 1,5 Ø20 Ø20 GND 1 2 34 5 6 7

12mm 12mm 12mm 12mm PF: 24V AC P: coil 17 mm 17 mm HP HH

14 mm 14 mm PF: 24V DC P: reed switch / NPN 24mm 24mm 6 x M12 24mm 24mm Ø12 36mm 36mm 36mm 36mm - + + 30mm (1.18") 30mm (1.18") PM: 115 - 230V AC P: PNP 0.9" HT HJ - + 22,50 mm ( 0.9") P: namur 1 7 7 7 /2"NPT Ø22 ( /8") Ø22 ( /8") Ø22 ( /8") - + 1.18" 1.18" P: active signal 0.9" HU HK +

1 /2"NPT 1 1 2 Flat bottom, no holes available. /2"NPT / "NPT A: (0)4 - 20mA

15mm 15mm + +

15 mm U: 0 - 10V HV + + 16 mm

38mm 4 x M20 x 1.5

HZ

F010 3 Typical wiring diagram F010-P-PB-(PX)-(ZB) Typical wiring diagram F010-A-PX-ZB

Type PB: Type PX: TERMINAL CONNECTORS BATTERY POWERED TERMINAL CONNECTORS BASIC 8 - 30V DC POWER SUPPLY F0 - series F0 - series (STANDARD)

Backlight option: type ZB Backlight supply 10 Backlight option: type ZB Backlight supply 10 20 - 30V DC 20 - 30V DC

(not used in this example)

Common ground 9 Common ground 9 +

Power supply type PX: 5 5 Power supply type PX: Main supply 8 - 30V DC Main supply 8 - 30V DC 8 - 30V DC

(not used in this example) Common ground 4 Common ground 4 -

Supply * 3 Signal Flowmeter input Signal type P:

type of signal pulse type of signal

Circuit depends on Circuit depends on Flowmeter input type A: (0)4 - 20mA Common ground 12 Common ground 12

* Sensor supply voltage for pulse flowmeter type P: * Sensor supply voltage for pulse flowmeter type P: Terminal 3: 1.2 / 3.2V DC. Terminal 3: 1.2 / 3.2V DC.

* Sensor supply voltage for analog flowmeter type A / U: * Sensor supply voltage for analog flowmeter type A / U: Terminal 3: not available. Terminal 3: not available.

Typical wiring diagram F010-A-PL-ZB Typical wiring diagram F010-P-PD-ZB

Type PL: Type PD:

TERMINAL CONNECTORS INPUT LOOP POWERED TERMINAL CONNECTORS 16 - 30V DC POWER SUPPLY

F0 - series F0 - series + Backlight option: type ZB 20 - 30V DC

Backlight supply 10 Backlight option: type ZB 20 - 30V DC Backlight supply 10 Common ground 9 - Common ground 9

Supply *

6 +

5 Power supply type PD: Main supply 16 - 30V DC

16 - 30V DC Common ground 4 -

Flowmeter input type A - PL: Supply *

Input loop powered 4 - 20mA 3

Signal + Signal Flowmeter input type P:

type of signal type of signal pulse

8 - 30V DC

Circuit depends on Circuit depends on Common ground 12 - Common ground 12

Sensor supply: sensor is externally powered. * Sensor supply voltage for pulse flowmeter type P: Terminal 3: 1.2 / 3.2V DC. Terminal 6 with type PD: 8.2V DC.

* Sensor supply voltage for analog flowmeter type A / U: Terminal 3: not available. Terminal 6 with type PD: voltage as connected to terminal 5 (internally linked).

4 F010 Typical wiring diagram F010-P-PF-ZB Typical wiring diagram F010-A-PF-ZB

Type PF: Type PF: TERMINAL CONNECTORS 24V AC / DC POWER SUPPLY TERMINAL CONNECTORS 24V AC / DC POWER SUPPLY F0 - series F0 - series

Backlight option: type ZB Backlight option: type ZB Internally powered. Internally powered.

Supply * Supply *

7 7 Flowmeter input type A: Signal Flowmeter input Signal (0)4 - 20mA type P:

type of signal pulse type of signal Circuit depends on Circuit depends on

Common ground 56 Common ground 56

2 2 Main supply 24V AC Main supply + 1 1 Power supply type PF: Power supply type PF: 24V DC

8 - 24V AC / DC 8 - 24V AC / DC Common ground 0 Earth Common ground 0 -

* Sensor supply voltage for pulse flowmeter type P: * Sensor supply voltage for pulse flowmeter type P: Terminal 7: 1.2 / 3.2 / 8.2 / 12 / 24V DC. Terminal 7: 1.2 / 3.2 / 8.2 / 12 / 24V DC.

* Sensor supply voltage for analog flowmeter type A / U: * Sensor supply voltage for analog flowmeter type A / U: Terminal 7: 8.2 / 12 / 24V DC. Terminal 7: 8.2 / 12 / 24V DC.

Typical wiring diagram F010-A-PM-ZB Typical wiring diagram F010-P-PM-ZB

Type PM: Type PM: TERMINAL CONNECTORS 115 - 230V AC POWER SUPPLY TERMINAL CONNECTORS 115 - 230V AC POWER SUPPLY F0 - series F0 - series

Backlight option: type ZB Backlight option: type ZB Internally powered. Internally powered.

Supply * Supply *

7 Flowmeter input type A: 7 Signal (0)4 - 20mA Signal Flowmeter input type P:

type of signal type of signal pulse Circuit depends on Circuit depends on

Common ground 56 Common ground 56

L1 L1 2 2 Main supply Power supply type PM: Main supply Power supply type PM: 115 - 230V AC 115 - 230V AC N N 1 1

Common ground 0 Common ground 0 Earth Earth

* Sensor supply voltage for pulse flowmeter type P: * Sensor supply voltage for pulse flowmeter type P: Terminal 7: 1.2 / 3.2 / 8.2 / 12 / 24V DC. Terminal 7: 1.2 / 3.2 / 8.2 / 12 / 24V DC.

* Sensor supply voltage for analog flowmeter type A / U: * Sensor supply voltage for analog flowmeter type A / U: Terminal 7: 8.2 / 12 / 24V DC. Terminal 7: 8.2 / 12 / 24V DC.

F010 5 Hazardous area applications Configuration example IIA - IIB and IIC The F010-XI has been certified according ATEX F010-P-PC-(PX)-XI-(ZB) - Battery powered unit and IECEx by KEMA and according CSA c-us and FM for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). • The ATEX markings for gas and dust applications are: II 1 G Ex ia IIC T4 II 1 D Ex iaD 20 IP 65/67 T 100 °C. • The IECEx markings for gas and dust applications are: Ex ia IIC T4 and Ex iaD 20 IP 65/67 T100 °C. • The CSA c-us markings are: Class I/II/III, Division 1, Groups A, B, C, D, E, F, G, Temperature class T4 and Class I, Zone 0, AEx ia IIC T4. • The FM markings are: Class I/II/III, Division

1, Groups A, B, C, D, E, F, G, Temperature HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS class T4 and Class I, Zone 0, AEx ia IIC T4. F0 - series It is allowed to connect up to three I.S. power Supply backlight Backlight option: type ZB 10 supplies to power the unit, sensor and back- (not used in this example). light. Consult the certificate for the maximum Common ground 9 input and output values of the circuits. The F010-PD-XI offers a 8.2V DC sensor supply to power e.g. a Namur sensor or the input voltage to power an analog sensor. An ATEX approved flame proof enclosure with rating II 2 GD Basic power supply type PX: 8 - 30V DC EEx d IIB T5 is available as well. Please contact Main supply 5 (not used in this example). your supplier for further details. Common ground 4

Certificate of conformity KEMA 05ATEX1168 X Supply * 3 I.S. flowmeter • IECEx KEM 08.0006X • CSA.08.2059461 X input type: P Signal type of signal pulse Circuit depends on

Common ground 12

* Sensor supply voltage for pulse flowmeter type P : Terminal 3: 1.2 / 3.2V DC. Please note: type PX may be used in combination with the battery (type PC). PX will power the unit; the battery will be disabled automatically till power is disconnected.

6 F010 Configuration example IIA - IIB and IIC - F010-P-PX-XI-(ZB) - Basic power supply 8 - 30V DC

HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS F0 - series

Supply backlight Backlight option: type ZB 10 (not used in this example).

Common ground 9 + Uo = max. 30V Power supply

Main supply 5 Power supply type PX: 8 - 30V DC Io = max. 200mA

For example - Po = max. 1,2W MTL 5525 Common ground 4

Supply * 3 I.S. flowmeter input type: P Signal type of signal pulse Circuit depends on

Common ground 12 Note: above values are safety values. Consult the technical specification for operational values. * Sensor supply voltage for pulse type P: Terminal 3: 1.2V / 3.2V DC. Please note: type PX may be used in combination with the battery (type PC). PX will power the unit; the battery will be disabled automatically till power is disconnected.

Configuration example IIA - IIB and IIC - F010-P-PX-XI-ZB - Basic power supply 8 - 30V DC

HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS

F0 - series + Uo = max. 30V Power supply Supply backlight 10 Io = max. 200mA

Backlight option: type ZB For example

- Po = max. 0,75W MTL 5525

Common ground 9 + Uo = max. 30V Power supply

Main supply 5 Power supply type PX: 8 - 30V DC Io = max. 200mA

For example - Po = max. 1,2W MTL 5525 Common ground 4

Supply * 3 + Uo = max. 30V Power supply I.S. flowmeter Signal type of signal input type: P Io = max. 150mA

For example Circuit depends on pulse - Po = max. 0,92W MTL 5525

Common ground 12 Note: above values are safety values. Consult the technical specification for operational values. * Sensor supply voltage for pulse type P: Terminal 3: 1.2V / 3.2V DC. Please note: type PX may be used in combination with the battery (type PC). PX will power the unit; the battery will be disabled automatically till power is disconnected.

F010 7 Configuration example IIA - IIB and IIC - F010-P-PD-XI-ZB - Power supply 16 - 30V DC

HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS

F0 - series + Uo = max. 30V Power supply Supply backlight 10 Io = max. 200mA

Backlight option: type ZB For example - Po = max. 0,75W MTL 5525 Common ground 9

Supply * 6 + Uo = max. 30V Power supply

Main supply 5 Power supply type PD: 16 - 30V DC Io = max. 200mA

For example - Po = max. 1,2W MTL 5525 Common ground 4

Supply * 3 I.S. flowmeter input type: P Signal type of signal pulse Circuit depends on

Common ground 12 Note: above values are safety values. Consult the technical specification for operational values. * Sensor supply voltage for pulse type P: Terminal 3: 1.2V / 3.2V DC. Terminal 6: 8.2V DC. Please note: type PD may be used in combination with the battery (type PC). PD will power the unit; the battery will be disabled automatically till power is disconnected.

Configuration example IIA - IIB and IIC - F010-A-PD-XI-ZB - Power supply 16 - 30V DC

HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS

F0 - series + Uo = max. 30V Power supply Supply backlight 10 Io = max. 200mA

Backlight option: type ZB For example - Po = max. 0,75W MTL 5525 Common ground 9

Supply * 6 + Uo = max. 30V Power supply

Main supply 5 Power supply type PD: 16 - 30V DC Io = max. 200mA

For example - Po = max. 1,2W MTL 5525 Common ground 4

I.S. flowmeter input - type A: (0)4 - 20mA

Signal type of signal Circuit depends on

Common ground 12 Note: above values are safety values. Consult the technical specification for operational values. * Sensor supply voltage for analog flowmeter type A / U: Terminal 6: as input voltage terminal 5 (internally linked). Please note: type PD may be used in combination with the battery (type PC). PD will power the unit; the battery will be disabled automatically till power is disconnected.

8 F010 Configuration example IIA - IIB and IIC - F010-A-PL-XI-ZB - Input loop powered

HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS

F0 - series + Uo = max. 30V Power supply Supply backlight 10 Io = max. 200mA

Backlight option: type ZB For example

- Po = max. 0,75W MTL 5525

Common ground 9 I.S. flowmeter input - type A-PL: 4 - 20mA input loop powered. + Uo = max. 30V Power supply Signal type of signal Io = max. 93mA

For example Circuit depends on - Po = max. 0,92W MTL 5525

Common ground 12 Note: above values are safety values. Consult the technical specification for operational values. Sensor supply is not available: unit is input loop powered (type PL). Please note: type PL may be used in combination with the battery (type PC). PL will power the unit; the battery will be disabled automatically till power is disconnected.

Configuration example IIA - IIB and IIC - F010-A-PX-XI-ZB - Basic power supply 8 - 30V DC

HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS

F0 - series + Uo = max. 30V Power supply Supply backlight 10 Io = max. 200mA

Backlight option: type ZB For example

- Po = max. 0,75W MTL 5525

Common ground 9 + Uo = max. 30V Power supply

Main supply 5 Power supply type PX: 8 - 30V DC Io = max. 200mA

For example

- Po = max. 1,2W MTL 5525

Common ground 4 I.S. flowmeter input - type A: (0)4 - 20mA + Uo = max. 30V Power supply Signal type of signal Io = max. 150mA

For example Circuit depends on - Po = max. 0,92W MTL 5525

Common ground 12 Note: above values are safety values. Consult the technical specification for operational values. * Sensor supply voltage for analog flowmeter type A / U: not available in this example. Please note: type PX may be used in combination with the battery (type PC). PX will power the unit; the battery will be disabled automatically till power is disconnected.

F010 9 Technical specification Casing General General Display Window Polycarbonate window. Type High intensity reflective numeric and Sealing Silicone. alphanumeric LCD, UV-resistant. Control keys Three industrial micro-switch keys. UV-resistant Dimensions 90 x 40mm (3.5" x 1.6"). silicone keypad. 1 Digits 5 /2 very large 26mm (1") digits. Various symbols and measuring units. Aluminum wall / field mount enclosures Piegraph Ten segments - related to the input signal. General Die-cast aluminum wall/field mount enclosure IP67 / Refresh rate User definable: fast, 1sec , 3sec, 15sec, 30sec, off. NEMA 4X with 2-component UV-resistant coating. Option ZB Transflective LCD with bi-color LED-backlight; Dimensions 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. green / amber. Intensitiy and color selected trough Weight 1100 gr. the keyboard. Good readings in full sunlight and Type HA Cable entry: 2 x PG9 and 1 x M20. darkness. Also available Intrinsically Safe. Type HM Cable entry: 2 x M16 and 1 x M20. Type HN Cable entry: 1 x M20. Operating temperature Type HO Cable entry: 2 x M20. Standard unit -40°C to +80°C (-40°F to +176°F). Type HP Cable entry: 6 x M12. 1 Intrinsically Safe -40°C to +70°C (-40°F to +158°F). Type HT Cable entry: 1 x /2" NPT. 1 Type HU Cable entry: 3 x /2" NPT. Type HV Cable entry: 4 x M20. Power requirements Type HZ Cable entry: no holes. Type PB Long life Lithium battery - life-time depends upon settings and configuration - up to 5 years. Type PC Intrinsically Safe long life lithium battery - life-time GRP wall / field mount enclosures depends upon settings and configuration - up to 5 General GRP wall/field mount enclosure IP67 / NEMA 4X, years. UV-resistant and flame retardant. Type PD 16 - 30V DC. Power consumption max. 1 Watt. Dimensions 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. Type PF 24V AC / DC ± 10%. Power consumption max. 15 Watt. Weight 600 gr. Type PL Input loop powered from sensor signal 4 - 20mA Type HD Cable entry: no holes. (type A). Type HE Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. 7 Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt. Type HF Cable entry: 1 x Ø 22mm ( /8"). Type PX 8 - 30V DC. Power consumption max. 0.3 Watt. Type HG Cable entry: 2 x Ø 20mm. Type ZB 20 - 30V DC. Power consumption max. 1 Watt. Type HH Cable entry: 6 x Ø 12mm. 7 With type PF / PM: internally powered. Type HJ Cable entry: 3 x Ø 22mm ( /8"). Note PB/PF/PM Not available Intrinsically Safe. Type HK Flat bottom, cable entry: no holes. Note PF/PM The total consumption of the sensor and backlight type ZB may not exceed 400mA @ 24V DC. Panel mount enclosures Note For Intrinsically Safe applications, consult the safety Dimensions 130 x 120 x 60mm (5.12" x 4.72" x 2.36") - W x H x D. values in the certificate. Panel cut-out 115 x 98mm (4.53" x 3.86") L x H. Type HB Die-cast aluminum panel mount enclosure IP65 / Sensor excitation NEMA 4X. Type PB/PC/PX 3.2V DC for pulse signals and 1.2V DC for coil Weight 600 gr. pick-up. Type HC GRP panel mount enclosure IP65 / NEMA 4X, Note This is not a real sensor supply. Only suitable for UV-resistant and flame retardant. sensors with a very low power consumption like coils Weight 450 gr. (sine wave) and reed-switches. Type PD for pulse signals: 1.2 / 3.2 / 8.2V DC - max. [email protected] DC. For analog signals, the sensor supply voltage is according to the power supply voltage Display example - 90 x 40mm (3.5" x 1.6") connected. Type PF / PM With pulse input: 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 400mA @ 24V DC. With analog input: 8.2 / 12 / 24V DC - max. 400mA @ 24V DC.

Terminal connections Type Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2.

Data protection Type EEPROM backup of all settings. Data retention at least 10 years. Pass-code Configuration settings can be pass-code protected.

10 F010 Hazardous area Accessories Intrinsically Safe Mounting accessories ATEX II 1 G Ex ia IIC T4. ACF02 Stainless steel wall mounting kit. certification II 1 D Ex iaD 20 IP 65 / 67 T 100 °C. ACF05 Stainless steel pipe mounting kit (worm gear clamps IECEx Ga Ex ia IIC T4. not included). certification Ex iaD 20 IP 65 / 67 T 100 °C. ACF06 Two stainless steel worm gear clamps Ø 44 - 56mm. CSA c-us Intrinsically Safe for Class I/II/III, Div. 1, ACF07 Two stainless steel worm gear clamps Ø 58 - 75mm. certification Groups A, B, C, D, E, F, G, Temp. class T4 ACF08 Two stainless steel worm gear clamps Ø 77 - 95mm. and Class I, Zone 0, AEx ia IIC T4. ACF09 Two stainless steel worm gear clamps Ø 106 - 138mm. FM certification Intrinsically Safe for Class I/II/III, Div. 1, ACF10 Customized Grevopal tagplates for ACF02 and ACF05, Groups A, B, C, D, E, F, G, Temp. class T4 including stainless steel screws. and Class I, Zone 0, AEx ia IIC T4. Dimension: 95mm x 12.5mm (3.75” x 0.50”). Ambient Ta -40°C to +70°C (-40°F to +158°F). Cable glands Explosion proof ACF20 For HA enclosure, includes O-rings. ATEX certification II 2 GD EEx d IIB T5. ACF25 For HE enclosure, includes locknuts and O-rings. Type XF Dimensions of enclosure: 300 x 250 x 200mm ACF26 For HF enclosure, includes locknuts and O-rings. (11.8" x 9.9" x 7.9") L x H x D. ACF27 For HG enclosure, includes locknuts and O-rings. Weight Appr. 15kg. ACF28 For HH enclosure, includes locknuts and O-rings. ACF29 For HJ enclosure, includes locknuts and O-rings. Environment ACF32 For HM enclosure, includes O-rings. Electromagnetic Compliant ref: EN 61326 (1997), EN 61010-1 (1993). ACF33 For HN enclosure, includes O-rings. compatibility ACF34 For HO enclosure, includes O-rings. ACF35 For HP enclosure, includes O-rings. ACF39 For HT enclosure, includes O-rings. Signal input ACF40 For HU enclosure, includes O-rings. Flowmeter sensor Type P Coil / sine wave (minimum 20mVpp or 80mVpp - Blind plugs sensitivity selectable), NPN/PNP, open collector, reed- ACF50 For HA enclosure, includes O-rings. switch, Namur, active pulse signals 8 - 12 and 24V DC. ACF55 For HE enclosure, includes locknuts and O-rings. Frequency Minimum 0Hz - maximum 7kHz for total and flow rate. ACF56 For HF enclosure, includes locknuts and O-rings. Maximum frequency depends on signal type and ACF57 For HG enclosure, includes locknuts and O-rings. internal low-pass filter. E.g. reed switch with ACF58 For HH enclosure, includes locknuts and O-rings. low-pass filter: max. frequency 120Hz. ACF59 For HJ enclosure, includes locknuts and O-rings. K-Factor 0.00001 - 199,999 with variable decimal position. ACF62 For HM enclosure, includes O-rings. Low-pass filter Available for all pulse signals. ACF63 For HN enclosure, includes O-rings. Option ZF coil sensitivity 10mVpp. ACF64 For HO enclosure, includes O-rings. Option ZG coil sensitivity 5mVpp. ACF65 For HP enclosure, includes O-rings. Type A (0)4 - 20mA. Analog input signal can be scaled to any ACF69 For HT enclosure, includes O-rings. desired range within 0 - 20mA. ACF70 For HU enclosure, includes O-rings. Type U 0 - 10V DC. Analog input signal can be scaled to any desired range within 0 - 10V DC. Intrinsically Safe isolators Accuracy Resolution: 16 bit. Error < 0.01mA / ± 0.05% FS. Low level cut-off programmable. ACG01 MTL5511 - One channel pulse or switch output Span 0.00001 - 199,999 with variable decimal position. transfer from hazardous area to safe area. Update time Four times per second. ACG02 MTL5525 - One channel power supply from safe area Voltage drop Type A: max. 1V DC @ 20mA. to hazardous area (e.g. to power the unit with PD or Voltage drop Type A - PL (loop powered): max. 2.6V DC @ 20mA. to power a switching or analog device in hazardous Load impedance Type U: 3kOhm. area). Relationship Linear and square root calculation. ACG03 MTL5541 - One channel 4 - 20mA repeater from Note For signal type A and U: external power to sensor is hazardous area to safe area. required; e.g. type PD. ACG04 MTL 5051 - Bi-direction serial-data-isolator (for Modbus communication). ACG05 MTL5516C - Two channel pulse or switch output Operational transfer from hazardous area to safe area. Operator functions ACG06 MTL5513 - One channel pulse or switch output Displayed • Flow rate. transfer from hazardous area to safe area. functions • Measuring and time units. ACG07 MTL5546Y - One channel isolated driver bringing 4 - 20mA from safe area to hazardous area, HART Flow rate transparent, OCD. 1 Digits 5 /2 digits. Units mL, L, m3, Gallons, kg, Ton, lb, bl, cf, RND, ft3, scf, Nm3, Nl, igal - no units. Decimals 0 - 1 - 2 or 3. Time units /sec - /min - /hr - /day.

F010 11 Ordering information Standard configuration: F010-P-HC-PX-XX-ZX. ordering information: F010 -_ -H _ -P _ -X _ -Z _ Flowmeter Sensor input signal A (0)4 - 20mA input. P Pulse input: coil, npn, pnp, namur, reed-switch. U 0 - 10V DC input. Panel mount enclosures - IP65 / NEMA4X HB Aluminum enclosure. HC GRP enclosure. GRP field / wall mount enclosures - IP67 / NEMA4X HD Cable entry: no holes. HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. HF Cable entry: 1 x Ø 22mm (7/8”). HG Cable entry: 2 x Ø 20mm. HH Cable entry: 6 x Ø 12mm. HJ Cable entry: 3 x Ø 22mm (7/8”). HK Flat bottom, cable entry: no holes. Aluminum field / wall mount enclosures - IP67 / NEMA4X HA Cable entry: 2 x PG9 + 1 x M20. HM Cable entry: 2 x M16 + 1 x M20. HN Cable entry: 1 x M20. HO Cable entry: 2 x M20. HP Cable entry: 6 x M12. HT Cable entry: 1 x 1/2”NPT. HU Cable entry: 3 x 1/2”NPT. HV Cable entry: 4 x M20. HZ Cable entry: no holes. Power supply PB Lithium battery powered. PC Lithium battery powered - Intrinsically Safe. PD 16 - 30V DC + sensor supply. PF 24V AC / DC + sensor supply. PL Input loop powered from sensor signal 4 - 20mA (type A). PM 115 - 230V AC + sensor supply. PX Basic power supply 8 - 30V DC (no real sensor supply). Hazardous area XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM. XF EExd enclosure - 3 keys. XX Safe area only. Other options ZB Backlight. ZF Coil input 10mVpp. ZG Coil input 5mVpp. ZX No options. The bold marked text contains the standard configuration. Available Intrinsically Safe.