HVAC Overview of Underfloor Air Distribution (UFAD)
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Investigation of the Impact of Commercial Building Envelope Airtightness on HVAC Energy Use
NISTIR 7238 Investigation of the Impact of Commercial Building Envelope Airtightness on HVAC Energy Use Steven J. Emmerich Tim McDowell Wagdy Anis NISTIR 7238 Investigation of the Impact of Commercial Building Envelope Airtightness on HVAC Energy Use Steven J. Emmerich Building and Fire Research Laboratory Timothy P. McDowell TESS, Inc. Wagdy Anis Shepley Bulfinch Richardson and Abbott Prepared for: U.S. Department of Energy Office of Building Technologies June 2005 U.S. Department of Commerce Carlos M. Gutierrez, Secretary Technology Administration Phillip J. Bond, Under Secretary of Commerce for Technology National Institute of Standards and Technology Hratch Semerjian, Acting Director ABSTRACT This report presents a simulation study of the energy impact of improving envelope airtightness in U.S. commercial buildings. Despite common assumptions, measurements have shown that typical U.S. commercial buildings are not particularly airtight. Past simulation studies have shown that commercial building envelope leakage can result in significant heating and cooling loads. To evaluate the potential energy savings of an effective air barrier requirement, annual energy simulations were prepared for three nonresidential buildings (a two-story office building, a one-story retail building, and a four-story apartment building) in 5 U.S. cities. A coupled multizone airflow and building energy simulation tool was used to predict the energy use for the buildings at a target tightness level relative to a baseline level based on measurements in existing buildings. Based on assumed blended national average heating and cooling energy prices, predicted potential annual heating and cooling energy cost savings ranged from 3 % to 36 % with the smallest savings occurring in the cooling-dominated climates of Phoenix and Miami. -
Displacement Ventilation in Action: Performance Monitoring of Demonstration Classrooms
Displacement Ventilation in Action: Performance Monitoring of Demonstration Classrooms Charles Eley and John Arent, Architectural Energy Corporation Bradley Meister, California Energy Commission ABSTRACT Displacement ventilation (DV) can provide better acoustics, improved indoor air quality, and reduced energy use for schools and other buildings. Recent research has used CFD simulation to determine supply air requirements and predict thermal comfort. However, there is a scarcity of performance data from these systems in practice. This paper presents recent research results from a Public Interest Energy Research (PIER) funded study of the technology and its application to K-12 schools. Two demonstration classrooms were continuously monitored over a six-month period to evaluate DV’s impact on thermal comfort, indoor air quality and energy use. Each of the displacement ventilation classrooms was compared to a control classroom that used a conventional packaged rooftop unit and overhead mixing air distribution. The demonstration and control classrooms were instrumented to record room temperature, carbon dioxide concentrations, relative humidity levels, and HVAC system electricity use. Temperatures were recorded at four different heights for each of three different locations to verify that thermal stratification in the space conforms to ASHRAE standards for thermal comfort. The monitoring data shows a consistent pattern of thermal stratification in the displacement classrooms. The displacement classrooms also have a lower CO2 concentration in the occupied zone than at the ceiling return, a sign of good ventilation effectiveness. Feedback from teacher surveys of thermal comfort, indoor air quality and acoustics is testament to the benefits of displacement ventilation. The results of the demonstration classrooms will help bridge the gap between theory and practice and will be a catalyst for market adoption. -
A Model for an Under Floor Air Distribution System
Energy and Buildings 37 (2005) 399–409 www.elsevier.com/locate/enbuild A model for an under floor air distribution system Y.J.P. Lina,*, P.F. Lindenb aEnergy and Resources Laboratories, Industrial Technology Research Institute, Hsinchu 310, Taiwan bDepartment of Mechanical and Aerospace Engineering, University of California, 9500 Gilman Drive La Jolla, San Diego, CA 92093-0411, USA Received 15 April 2004; received in revised form 30 July 2004; accepted 31 July 2004 Abstract We present a simplified model of an underfloor air distribution (UFAD) system consisting of a single source of heat and a single cooling diffuser in a ventilated space. Laboratory experiments were carried out to simulate the flow and a model for the flow in this space is proposed. The model is based on plume theory for the heat source and a fountain model for the diffuser flow, and predicts a steady-state two-layer stratification in the room. The governing parameters are shown to be the buoyancy flux of the heat source, and the volume and momentum fluxes of the cooling diffuser. The results suggest ways to optimize UFAD design and operation. # 2004 Elsevier B.V. All rights reserved. Keywords: UFAD system; Penetrative entrainment; Turbulent plume; Turbulent fountain; Displacement ventilation; Mixing ventilation 1. Introduction Bauman and Webster [2] show that well-designed UFAD systems can provide such benefits as: The motivation for this study is to understand and model the behavior of an under floor air distribution system reduced life cycle building costs; (hereafter referred to as UFAD) in a ventilated room. This improved thermal comfort; system was first introduced in the 1950s to cool a computer improved ventilation efficiency and indoor air quality; room and is emerging as a leading ventilation system design reduced energy use; in modern commercial buildings. -
Download the Brochure
The trusted partner that clients continually rely upon to solve their most complex design challenges and building issues serviced through an exceptional consultant experience. WE DELIVER SUSTAINABLE BUILDING SOLUTIONS WHILE RESPECTING ASPIRATIONAL PROJECT GOALS. WE BUILD LASTING RELATIONSHIPS WITH OUR CLIENTS, COLLABORATORS, AND EACH OTHER. WE ARE FOCUSED ON PROJECT EXECUTION AND EXCEL AT CLIENT DELIVERABLES AND CONSULTING SERVICES. Firm Profile DeSimone Consulting Engineers provides high-quality structural engineering, facade consulting, and forensic services, in addition to risk management and construction claims consulting for all types of buildings. Known for the highest quality of service, the firm provides each client with personal, dedicated, and inspiring engineering solutions. Founded in New York City in 1969, the firm is organized to support clients around the country and around the globe with offices in the United States, South America, and the Middle East. To date, DeSimone has designed over 10,000 projects in 44 states and 55 countries. Our project portfolio demonstrates the firm’s dedication to pursuing and developing superlative structures. The firm is also consistently listed on Engineering News Record’s Top 500 Design Firms. DeSimone produces extremely efficient designs and is known for creative thinking and for outright innovation. The firm combines cutting edge technology with seasoned experience to provide professional services unmatched in the industry. DeSimone’s approach is process driven, utilizing an open office, collaborative design environment. Technology, communication, and responsiveness are key strengths that facilitate the firm’s commitment to exceptional service, and engender the creation of a better-built environment. Global Presence DeSimone has offices throughout the United States, the Middle East, and South America. -
Heat Transfer Pathways in Underfloor Air Distribution (UFAD) Systems
UC Berkeley HVAC Systems Title Heat transfer pathways in underfloor air distribution (UFAD) systems Permalink https://escholarship.org/uc/item/52f04592 Authors Bauman, F. Jin, H. Webster, T. Publication Date 2006 Peer reviewed eScholarship.org Powered by the California Digital Library University of California © 2006, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions, Vol 112, Part 2. For personal use only. Additional distribution in either paper or digital form is not permitted without ASHRAE's permission. QC-06-053 Heat Transfer Pathways in Underfloor Air Distribution (UFAD) Systems Fred S. Bauman, PE Hui Jin, PhD Tom Webster, PE Member ASHRAE Member ASHRAE Member ASHRAE Please note that the following two statements have been of cooling airflow needed to remove heat loads from a building added as a result of the peer-review process for this paper: space using the assumption of a well-mixed room air condi- Results of heat gain shown in this theoretical steady-state tion. The familiarity of designers with this relatively simple model may be greater than those found in actual practice for equation has led to a situation in which design space heat gains UFAD systems. This may be for a number of reasons that are (i.e., total room cooling loads) are considered synonymous not now understood and should be the basis for further research with return air extraction rates, and cooling airflows are found and study. from the (mixed) room-supply temperature difference, typi- cally assumed to be 11°C (20°F). In a stratified underfloor air ABSTRACT distribution (UFAD) environment, the assumption of perfect This paper reports on a modeling study to investigate the mixing is no longer valid, requiring a different way of thinking primary pathways for heat to be removed from a room with about energy flows and airflow quantities. -
Optimal Forced-Air Distribution in New Housing
ptimal F fee ~ ir istributi n in New H usin John ~ Andrews Introduction Cooling~Load Characteristics of the Optimized House Studies of forced-air thermal distribution systems in small buildings show that significant energy losses are common A calculation of the peak cooling load in New York State in ductwork. These losses stem from several mechanisms, was performed for both a conventional house and the opti including duct leakage, thermal conduction through duct mized design that would replace it (Andrews et aL 1989). walls, and selective pressurization and depressurization of The conventional house was a single-story 1500 ft2 different zones of the house when the air-distribution fan 2 [140 m ] structure with R-l1 insulation in the wans, R-20 is operating. One way to reduce or eliminate duct losses is in the ceiling, unshaded window area 15 % of the south to place the ductwork within the conditioned space, rather wall and 10% of the other wans, and an average summer than the more usual attic, crawlspace, or basement loca time air infiltration rate of 0.7 air changes per hour tions. This approach is encouraged by new standards such (ACH) .. Calculated heat gains from various sources are as ASHRAE 90.2. shown in the first column of Table 1e Duct losses equal to 30% of the cooling input are assumed here, within the A major impediment to this solution is the size and range of recent results (Cummings and Tooley 1989, unsightliness of the ductwork. If ducts could be made Modera et ale 1991). smaller in cross section, builders might be motivated to them within the conditioned space. -
Simplified Modelling of Displacement Ventilation
UNIVERSIDADE DE LISBOA FACULDADE DE CIÊNCIAS Simplified Modelling of Displacement Ventilation Doutoramento em Energia e Ambiente Especialidade em Energia e Desenvolvimento Sustentável Nuno André Marques Mateus Tese orientada por: Professor Doutor Guilherme Carvalho Canhoto Carrilho da Graça Documento especialmente elaborado para a obtenção do grau de doutor 2016 UNIVERSIDADE DE LISBOA FACULDADE DE CIÊNCIAS Simplified Modelling of Displacement Ventilation Doutoramento em Energia e Ambiente Especialidade em Energia e Desenvolvimento Sustentável Nuno André Marques Mateus Tese orientada por: Professor Doutor Guilherme Carvalho Canhoto Carrilho da Graça Júri: Presidente: ● Doutor João Catalão Fernandes (Faculdade de Ciências, Universidade de Lisboa) Vogais: ● Doutor Paul Linden (Faculty of Mathematics, University of Cambridge) ● Doutor Eusébio Zeferino da Conceição (Faculdade de Ciências e Tecnologia, Universidade do Algarve) ● Doutor João Manuel de Almeida Serra (Faculdade de Ciências, Universidade de Lisboa) ● Doutor Guilherme Carvalho Canhoto Carrilho da Graça (Faculdade de Ciências, Universidade de Lisboa) ● Doutora Marta João Nunes Oliveira Panão (Faculdade de Ciências, Universidade de Lisboa) Documento especialmente elaborado para a obtenção do grau de doutor 2016 Acknowledgements This work would not have been possible without the financial support of Calouste Gulbenkian Foundation through Ph.D. Grant No. 126724. I am grateful to my supervisor professor Guilherme Carrilho da Graça, for having accepted to guide me, for all the opportunities he provided me and the challenges he put me through which allowed me to learn more than I could ever expected. To Filipa Silva, Daniel Albuquerque, António Soares and all the other students that contributed for an incredibly friendly and supportive working atmosphere in the “buildings team”. To all my friends, for the friendship and support. -
Effects of Climate Change on the Moisture Performance of Tallwood Building Envelope
buildings Article Effects of Climate Change on the Moisture Performance of Tallwood Building Envelope Maurice Defo * and Michael A. Lacasse National Research Council Canada, 1200 Montreal Road, Ottawa, ON K1A 0R6, Canada; [email protected] * Correspondence: [email protected] Abstract: The objective of this study was to assess the potential effects of climate change on the moisture performance and durability of massive timber walls on the basis of results derived from hygrothermal simulations. One-dimensional simulations were run using DELPHIN 5.9.4 for 31 con- secutive years of the 15 realizations of the modeled historical (1986–2016) and future (2062–2092) climates of five cities located across Canada. For all cities, water penetration in the wall assembly was assumed to be 1% wind-driven rain, and the air changes per hour in the drainage cavity was assumed to be 10. The mold growth index on the outer layer of the cross-laminated timber panel was used to compare the moisture performance for the historical and future periods. The simulation results showed that the risk of mold growth would increase in all the cities considered. However, the relative change varied from city to city. In the cities of Ottawa, Calgary and Winnipeg, the relative change in the mold growth index was higher than in the cities of Vancouver and St. John’s. For Vancouver and St. John’s, and under the assumptions used for these simulations, the risk was already higher under the historical period. This means that the mass timber walls in these two cities could not withstand a water penetration rate of 1% wind-driven rain, as used in the simulations, with a drainage cavity of 19 mm and an air changes per hour value of 10. -
Tierra-Linda-Passive-House-Design
TIERRA LINDA Passive House Design About The Project In July 2014, Latin United Community Housing Association (LUCHA) led an interactive eco-charrette to generate and target sustainability goals for its new wellness-centered scattered-site housing development called Tierra Linda, located near the 606 Trail in Humboldt Park. The project kick-off brought together members of the LBBA design team with the maintenance staff, tenants, and neighbors of the future development and introduced the benefits of “green” housing and collaboratively developed a vision and strategies for the project. LUCHA incorporated key tactics into the development of Tierra Linda that supports the core theme of healthy living and wellness integrated amongst tenants and the community. The project has received Passive House certification—the first affordable multi-family housing type to achieve PH certification in Chicago! In addition to the Passive House 6-flat, the development also includes a “twin” building that is designed to comply with code-minimum energy requirements which will allow the team to compare energy usage between the two. What Is Passive House? Passive House is a building standard popular in Europe and Canada. However in recent years, Passive House Alliance launched a United States program aimed at making high- performance passive building the mainstream market standard. Passive building is made up of a set of design principles used to attain rigorous level of energy efficiency within a quantifiable comfort level. To that end, a passive building is designed and built in accordance with these five building science principles: 1. Employs continuous insulation throughout its entire envelope without any thermal bridging. -
Theoretical and Experimental Study of Combined System: Chilled Ceiling and Displacement Ventilation
Universal Journal of Mechanical Engineering 7(3): 118-138, 2019 http://www.hrpub.org DOI: 10.13189/ujme.2019.070305 Theoretical and Experimental Study of Combined System: Chilled Ceiling and Displacement Ventilation Israa Ali AbdulGhafor1,*, Adnan A. Abdulrasool2, Qasim S. Mehdi2 1Lecturer, Department of Electronic Technique, Middle Technical University, Iraq 2Professor, Department of Mechanical Engineering, Al-Mustansiriya University, Iraq Copyright©2019 by authors, all rights reserved. Authors agree that this article remains permanently open access under the terms of the Creative Commons Attribution License 4.0 International License Abstract The present experimental study presents the obtain with using HVAC systems that supply enough of performance of the combine cooling system (chilled quantity of fresh air to the occupied zone whilst effectively ceiling and displacement ventilation). The experimental elimination contaminants. So, HVAC, systems provide study included the effect of different temperatures of suitable air temperature by elimination heat from occupied chilled ceiling of (20 and 16)°C and different supplied air zone while avoid large air temperature gradients and drafts. temperatures of (18, 20, 22 and 24)°C with constant Economic side should be achieved by both thermal and internal load of 1600W and constant supplied air velocity indoor air quality requirements, because the largest energy of 0.75m/s. The theoretical study content studying the air consumption is done by these systems. According to recent flow pattern through occupant zone and temperatures researches more than 40% of total energy used by contours in different directions X, Y and Z at supplied air commercial building is consumption by HAVC systems temperature (18)°C and internal load, mean plate [1]. -
Underfloor Air Distribution (UFAD)
Underfloor Air Distribution Underfloor Air Distribution Introduction Underfloor Air Distribution (UFAD) is an alternative to traditional overhead air distribution that delivers air from a pressurized air plenum beneath a raised access floor, relying on the natural buoyancy of air to remove heat and contaminants. Price offers both UFAD Mixing Systems turbulent flow (mixing) and 63-65°F supply air 55°F supply air displacement flow Mixes the “occupied Mixes the entire space underfloor diffusers zone” only Stratified temperature Uniform temperature and Turbulent Flow and contaminant levels contaminant levels Displacement Flow What is stratification? Stratification refers to a non-uniform temperature throughout a zone, with higher temperatures towards the ceiling and lower temperatures towards the floor. In a stratified room, return air is warmer and has a higher level of contaminants than supply air does. What is the occupied zone? Displacement diffusers result in more The occupied zone refers to the space in a room that begins one pronounced stratification and lower velocity profiles in the room, often foot from all walls and extends from the floor to six feet above the leading to improved indoor air quality floor. Mixing the occupied zone instead of the whole space can and thermal comfort. result in energy savings in spaces with high ceilings. 2 priceindustries.com Advantages Flexibility Diffusers installed in a raised floor can be reconfigured at a fraction of the time and cost of an overhead system. Given the prevalence of churn in a modern office environment, a highly configurable HVAC system can be a great cost savings in these environments. -
Analysis for Building Envelopes and Mechanical Systems Using 2012 CBECS Data March 2018
PNNL-26949 Analysis for Building Envelopes and Mechanical Systems Using 2012 CBECS Data March 2018 DW Winiarski AL Cooke MA Halverson GK Bandyopadhyay JB Butzbaugh DB Elliott Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 PNNL-26949 Analysis for Building Envelopes and Mechanical Systems Using 2012 CBECS Data DW Winiarski AL Cooke MA Halverson GK Bandyopadhyay JB Butzbaugh DB Elliott March 2018 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Pacific Northwest National Laboratory Richland, Washington 99352 Summary This report describes the aggregation and mapping of certain building characteristics data available in the most recent Commercial Building Energy Consumption Survey (CBECS) (DOE EIA 2012) to describe most typical construction practices. Buildings with a date of construction of 1990 or later (referred to as post-1990) were analyzed as a reflection of more recent building construction practices. This report provides summary data for potential use in the support of modifications to the Pacific Northwest National Laboratory’s (PNNL’s) commercial prototype building models (prototypes) used for building energy code analysis. Mapping of CBECS data to building construction characterized in the building code was conducted to provide actionable insight. This summary outlines findings and most typical design choices for certain building envelope and heating, ventilating, and air-conditioning (HVAC) systems for the prototypes based primarily on the most recent CBECS data. While the conclusions in this summary are reflective of current construction, as captured in the CBECS data, the commercial building prototypes form the basis of other analytical work for PNNL, and any subsequent modifications to the prototypes based on the findings in this report should take into account the historical use of the prototypes as well as other data used in their development.