Schedule of Products

WaterMark Certification Scheme

WaterMark Certification Scheme

Contents Schedule of Products ...... 1 Introduction ...... 3 Appliances ...... 5 Sanitary fixtures ...... 7 Tapware ...... 9 Systems ...... 11 Devices and Controllers ...... 12 Heated Water Products ...... 14 Valves - Isolation ...... 16 Valves – Backflow prevention...... 18 Valves – General ...... 22 Fire service ...... 25 Jointing products ...... 26 Pipes – Metallic ...... 29 Pipes – Plastic ...... 31 Pipes – Other ...... 34 Fittings – Metallic ...... 35 Fittings – Plastic ...... 39 Fittings – Other ...... 43 Shafts and pumping stations ...... 44

Page | 2

Introduction The WaterMark Certification Scheme is a mandatory certification scheme for certain plumbing and drainage products to ensure they are fit for purpose for use in a plumbing and drainage installation. The ABCB manages and administers the Scheme. The National Construction Code – Volume Three, Plumbing Code of Australia (PCA) requires certain plumbing and drainage products to be certified and authorised for use in a plumbing or drainage installation. The scope of the WaterMark Certification Scheme is based on the following principles: a) The installation of the product is covered by the PCA and regulated by all States and Territories (excluding State and Territory variations, which vary how the product is regulated through the PCA); b) The objectives of the Scheme1; and c) The product category is to present a public risk requiring mitigation through the Scheme, as determined by the Protocol for the Assessment of Risks of Plumbing Products2 and subsequent listing on the WaterMark Schedule of Products. It is important to note that not all plumbing and drainage products require WaterMark certification. However, all materials and products proposed to be used in a plumbing and drainage installation require a risk assessment to determine if WaterMark certification is necessary. This document, the WaterMark Schedule of Products, lists products that have been predetermined to require WaterMark certification. Another document available from the ABCB website, the WaterMark Schedule of Excluded Products, lists products that have been predetermined to not require WaterMark certification to meet the requirements of the PCA. Within this schedule a number of products are marked with ‘TBA’. This indicates where a product has been risk assessed and has been identified as having risks requiring mitigation through the WaterMark Certification Scheme and a specification is currently in development.

1 ABCB, Manual for the WaterMark Certification Scheme, page 23. 2 ABCB, Manual for the WaterMark Certification Scheme, page 85. Page | 3

From time to time the WaterMark Administration may issue Notices of Direction (NoD) which relevant stakeholders must comply with. Any NoD published which may be of relevance to a product or product specification listed on this schedule has been identified within a note. This document is uncontrolled when printed, the information contained within changes from time to time. You should consult the ABCB website to verify its currency.

Page | 4

Appliances Product Scope/Application Specification Year

WMTS.104 Appliances Bedpan washer/sterilizer Health Care. 2016 (miscellaneous) WMTS.101 Appliances (low hazard Clothes washing machine Commercial. 2016 rating) Chilled beverage & ice dispensing machines used Commercial chilled beverage WMTS.105 Appliances – Beverage primarily for commercial use to dispense ice, water and 2016 and ice dispenser dispensers and icemakers soda type beverages. Commercial heated beverage Heated, boiling water and coffee dispensing equipment. TBA dispenser Ice used primarily for human consumption, food storage or WMTS.105 Appliances – Beverage Commercial ice maker 2016 food preparation. dispensers and icemakers WMTS.101 Appliances (low hazard Dish washing machine Commercial. 2016 rating) Disposable nappy disposal WMTS.104 Appliances Health care. 2016 unit (miscellaneous) Drinking fountains and bottle WMTS.105 Appliances – Beverage Cold or chilled water dispensing apparatus. 2016 fillers dispensers and icemakers

Food waste disposal units Domestic and commercial WMTS.028 Food waste disposal unit 2018

WMTS.101 Appliances (low hazard Fruit/vegetable peeler Commercial. 2016 rating) WMTS.101 Appliances (low hazard Glass washing machine Commercial. 2016 rating) Placenta/surgical waste WMTS.104 Appliances Health care. 2016 disposal unit (miscellaneous) WMTS.104 Appliances Sanitary napkin disposal unit Health care. 2016 (miscellaneous) WMTS.525 Appliances - Therapeutic Therapeutic Bath Health care. 2018 baths

Version: 2018 - 2

Product Scope/Application Specification Year

Point of use (POU), point of entry (POE), and stand-alone AS/NZS 3497 Drinking water appliances designed for the reduction of specific groups of treatment units – Plumbing 1998 Water filters and water containments. requirements treatment appliances Storage tanks, Deionizing tanks, Strainers, Water WMTS.103 Water treatment systems sanitizers, Water treatment units, (upstream of appliances) (other than those specified in AS/NZS 2016 and UV (for non-drinking water purposes, i.e., bathing). 3497) Spraying of fertilizers, insecticides, detergents, degreasers WMTS.033 Spraying apparatus 2016 or similar contaminable liquids to the atmosphere. Spray apparatus Spray apparatus not intended to directly supply drinking water, considered a low risk of back siphonage, connected WMTS.101 Appliances (low hazard 2016 to the water service and/or sanitary plumbing/drainage rating) Note: See NoD 2013/10.1 system. Steamers not intended to directly supply drinking water, WMTS.101 Appliances (low hazard Steamer considered a low risk of back siphonage, connected to the 2016 rating) water service and/or sanitary plumbing/drainage system. Humidifiers not intended to directly supply drinking water, WMTS.101 Appliances (low hazard Humidifier considered a low risk of back siphonage, connected to the 2016 rating) water service and/or sanitary plumbing/drainage system. Sterilizers not intended to directly supply drinking water, WMTS.104 Appliances Sterilizer considered a low risk of back siphonage, connected to the 2016 (miscellaneous) water service and/or sanitary plumbing/drainage system. The rice washer appliance washes and then stores Rice washer TBA washed rice for cooking purposes. Combi oven Commercial. TBA The bed pan macerator appliance is designed to discharge Bedpan macerator disposable bedpan liners and bottles together with their TBA waste content to the sanitary drainage system.

Page | 6 Version: 2018 - 2

Sanitary fixtures Product Scope/Application Specification Year Bidets intended for use with douche spray below the rim of the bowl. Bidets are not Bidet AS 3494 Bidettes and bidets 1997 suitable for direct connection to the drinking water supply. Douche seats using water dispensed by a douche spray for the purposes of personal Bidet douche seats WMTS.051 Bidet douche seats 2016 hygiene that are self-contained for installation on water closet (WC) pans. Bidettes that can be fitted with over-the-rim taps. Bidettes with the prescribed minimum Bidette air gap measured after tapware has been AS 3494 Bidettes and bidets 1997 fitted may be directly connected to the drinking water supply. Flushing cisterns that may either be single- Cistern flush or dual-flush which are intended for use AS 1172.2 Water closets (WC's) - Flushing 2014 with urinals and water closet pans of all devices and cistern inlet and outlet valves Note: See NoD 2016/1.1 types. Note: See NoD 2017/4.1 Intended as a replacement for, or retrofitted to, flushing cisterns of the types specified in AS 1172.2 Water closets (WC's) - Flushing Cistern outlet 2014 this Standard. The operating function may be devices and cistern inlet and outlet valves of the single- or dual-flush type. Note: See NoD 2017/4.1 Cistern inlet valves intended for use in gravity-fed applications shall operate at a AS 1172.2 Water closets (WC's) - Flushing Cistern inlet minimum supply pressure of 5 kPa, whilst devices and cistern inlet and outlet valves 2014 meeting minimum flow rate requirements as specified in this Standard. Note: See NoD 2017/4.1 Waterless wall-hung urinals manufactured WMTS.459 Waterless urinals - Wall-hung 2018 Urinal from vitreous china, plastic or stainless steel. Slab, stall, trough and wall hung urinals made AS/NZS 3982 Urinals 1996 from vitreous china, and stainless steel

Page | 7 Version: 2018 - 2

Product Scope/Application Specification Year Urinals manufactured from vitreous china, plastics, composite or stainless steel, with an WMTS.469 Waterless or limited flush integral self-sealing device that can either be 2018 urinals - With an integral sealing device waterless or flushed with a limited volume of water. SA TS 100 Vacuum WC pans, vacuum Vacuum urinals intended for use with vacuum urinals and interface valves intended for use 2018 drainage systems. with vacuum drainage systems and designs Pans intended for use with flushing cisterns AS 1172.1 Water closets (WC's) – Pans and other flushing devices, including mains 2014 Note: See Nod 2017/4.1 and break tank supplied flushing valves. Electronically operated water closet (WC) WMTS.516 Water closet (WC) - Pan and pan and flushing device with included flushing device with included macerating 2014 Water closet macerating and lifting plant. and lifting plant SA TS 100 Vacuum WC pans, vacuum Vacuum WC pans intended for use with urinals and interface valves intended for use 2018 vacuum drainage systems. with vacuum drainage systems and designs Water closet suite with integral odour control WMTS.425 Water closet (WC) suite with 2016 device. integral odour control device (OCD) Flushing sink Flushing rim with DN 100 spigot WMTS 526 Flushing sink 2018

Page | 8 Version: 2018 - 2

Tapware Product Scope/Application Specification Year

Beverage dispensing tapware Chilled, cold, heated, boiling and sparkling water drink TBA and equipment dispensing machines and equipment. Metallic taps, plastic taps, mixing taps, sensor (non-touch) taps, lever taps, timed flow taps, mixing taps mechanical (non-thermostatic), and tapsets in a range of nominal sizes from DN 6 to DN 50, generally for continuous operating AS/NZS 3718 Water supply - Tap Tapware temperatures not exceeding 80°C. Including the following 2005 ware tap types: bib, bidette, stop, mixing (non-thermostatic), non-touch, washing machine stop, hose, diaphragm, pillar, laboratory, hand spray, drinking fountain, self-closing, ferrule and tapware with an integral pop up-waste. Metallic taps, plastic taps, mixing taps, sensor (non-touch) taps, lever taps, timed flow taps, mixing taps mechanical (non-thermostatic), and tapsets in a range of nominal sizes from DN 6 to DN 50, generally for continuous operating temperatures not exceeding 80°C. Including the following AS/NZS 3718 Water supply - Tap Tap accessories 2005 tap accessories: Breaching set, jumper valve assembly, o- ware ring, outlet, removable tap seat, replacement seat – copper alloy, replacement seat – stainless steel, spindle, tap body, tap head, tap head assembly and tapset breaching piece. A showerhead through which water is intended to pass to form a spray for bathing purposes, which may include a AS/NZS 3662 Performance of 2005 fixed or pivot arm, a flexible hose (with or without a flow showers for bathing Shower controller), tap top assemblies, or other components. Metallic taps, plastic taps, mixing taps, sensor (non-touch) AS/NZS 3718 Water Supply - taps, lever taps, timed flow taps, mixing taps mechanical 2005 Tapware (non-thermostatic), hand spray and tapsets in a range of

Page | 9 Version: 2018 - 2

Product Scope/Application Specification Year

nominal sizes from DN 6 to DN 50, generally for continuous operating temperatures not exceeding 80°C. Thermostatic mixing taps used for ablutionary purposes for AS 4032.4 Water supply - Valves for use with heated water: the control of heated water supply Thermostatically controlled a) at a supply temperature not exceeding 90°C; temperatures -Thermostatically 2014 taps b) with working pressures not exceeding 1400 kPa; and controlled taps for the control of c) of nominal sizes not larger than DN 20. heated water supply temperatures Flexible hose assemblies for use with both heated water at 70°C and 1000 kPa maximum and cold-water supplies at 1200 kPa maximum used for applications above ground, AS/NZS 3499 Water supply - Flexible Flexible hose assemblies 2006 accessible and not submerged. Nominal sizes range up to hose assemblies DN 20, a maximum length of 2 m and with a working pressure not exceeding 1400 kPa.

Page | 10 Version: 2018 - 2

Systems Product Scope/Application Specification Year

Purpose-built bathroom Bathroom or shower modules which include integral module components, accessories and fittings, designed for direct WMTS.050 Prefabricated bathroom 2018 connection to the water supply and sanitary drainage modules Note: See Nod 2016/4.0 system. Bathroom appliance which intergrates the following fixtures and fittings for concealment when not in use: a) Water closet pan and flishing device; Bathroom appliance WMTS.524 Bathroom appliances 2018 b) Basin; and c) Pipework and fittings to enable connectivity to water services and sanitary plumbing and drainage systems. Modulat heated water systems for the generation of heated water which may incorporate hot, cold and AS 3498 Water heaters and hot-water Modular heated water system 2009 tempered water systems, water heaters and heated and storage tanks cold water storage tanks. WMTS.504 Sanitary Waste Flushing Sanitary Waste Flushing and Dosing System – Water Dosing System (SWFDS) - Water Sanitary Waste Flushing and Closet 3/2 L Capacity or Proven Equivalent with Included Closet (WC) 3/2 L Capacity or Proven 2013 Dosing System (SWFDS) Sewer Dosing Unit Equivalent with Included Sewer Dosing Unit (SDU) Wash down diversion systems for connection to suitable WMTS.046 Diversion systems – Wash down diversion system 2016 drainage Wash down and Notes:

1 Where the system includes integral plumbing components, accessories or fittings that require certification as identified in the Plumbing Code of Australia, they shall comply with the applicable requirements of the specification for that product, as identified in this schedule.

2 Where the system includes components or accessories they may be subject to other regulatory requirements e.g. electrical safety, electromagnetic compatibility (EMC), gas safety and energy and water efficiency.

Page | 11 Version: 2018 - 2

Devices and Controllers Product Scope/Application Specification Year

Requirements for water meters used to meter the actual volume of cold and heated drinking and non-drinking water AS 3565.1 Meters for cold and heated Meter flowing through a fully charged closed conduit. drinking and non-drinking water 2010 Note: Only meters installed within the scope of the PCA supplies - Technical requirements require certification. Pressure-compensating flow control devices that deliver a WMTS.037.1 Flow controllers – For fixed and constant flow rate, throughout a given pressure controlling flows in cold or heated 2016 differential range. water systems Flow control valve AS 5200.037.2 Plumbing and Flow controllers with or without bodies, for use in heated or drainage products - Flow controllers cold water plumbing systems that may be required to be 2008 for use with heated or cold water rated in accordance with AS/NZS 6400. systems diversion devices employing gravity or pumped discharge, designed to be used in the sanitary drainage WMTS.460 Grey water diversion Grey water diversion device system to divert grey water. 2016 device Note: Products that require connection to a water service are outside the scope. Low pressure automated changeover devices of nominal WMTS.466 Rainwater tank sizes DN15 and DN20 and nominal operating pressure up 2016 connection devices to and including 400 kPa. Automated valves of nominal sizes DN 20/25 and nominal WMTS.467 Rainwater tank Rainwater tank connection 2016 working pressure PN 16. connection valve Manual or automated changeover devices of nominal sizes WMTS.477 Rainwater/mains supply DN 20/25 and maximum allowable operating pressures up 2016 changeover devices to and including 1600 kPa. Inline sewer dosing units (SDUs) intended to temporarily WMTS.499 Inline sewer dosing unit Sewer dosing unit store and deliver measured volumes of waste water to the 2016 (SDU) sewer line.

Page | 12 Version: 2018 - 2

Product Scope/Application Specification Year

WMTS.498 Plastic Fittings - Overflow Plastic bodied DN 100 overflow relief waste outlet with Overflow relief waste outlet Relief Waste Outlet (ORWO) with 2014 integral cap-stopper. Integral Cap-stopper Moulded PVC-U anti-infiltration overflow-relief devices, of WMTS.501 Anti-infiltration overflow- Anti infiltration device nominal size DN 100, that are intended, upon installation 2016 relief device in an overflow relief gully (ORG). Metallic bodied safety shut valve for use in hot and cold water applications where the maximum operating pressure Leak protection device WMTS.479 Flood stop safety valve 2018 does not exceed 1400 kPa and the maximum temperature does not exceed 85ºC.

A pressure-compensating tank, for use within cold and WMTS.485 Pressure compensating Pressure compensating tank heated water supply systems incorporating water supply 2018 tank pumps or systems with fluctuating pressures.

Prefabricated cold water storage tanks constructed from copper, galvanized steel, stainless steel, plastics and Prefabricated cold water dezincification-resistant copper alloy up to 50,000 L WMTS.026 Cold water storage tanks 2016 storage tank capacity installed within a cold water system. Note: This excludes tanks installed outside of the scope of the PCA. Metal-bodied water hammer arresters of DN 15 to DN 50 AS 5200.007 Metal-bodied water Water Hammer arrestor sizes for heated (up to 80°C) and cold-water applications 2008 hammer arresters and supply pressures up to 1.2 MPa. This product is designed for draining hot and cold water Hot & cold water flushing systems at end of line/riser or ring circuits to manage and TBA station meet with legionella control. This device measures flow or flow and temperature within Flow sensor TBA a water supply system (drinking or non drinking

Page | 13 Version: 2018 - 2

Heated Water Products Product Scope/Application Specification Year

AS 3498 Water heaters and hot-water storage Instantaneous (continuous Electric resistance. 2009 tanks flow) water heater Gas, such as Liquefied petroleum gas AS 3498 Water heaters and hot-water storage 2009 (LPG) and Natural gas NG). tanks Electric resistance (direct and AS 3498 Water heaters and hot-water storage 2009 indirect). tanks Storage water heater Gas, such as Liquefied petroleum gas AS 3498 Water heaters and hot-water storage 2009 (LPG) and Natural gas NG). tanks AS 3498 Water heaters and hot-water storage Solar water heating system N/A 2009 tanks AS 3498 Water heaters and hot-water storage Heat exchange water heaters N/A 2009 tanks AS 3498 Water heaters and hot-water storage Calorifier N/A 2009 tanks Heated water and pre-heat AS 3498 Water heaters and hot-water storage N/A 2009 storage tanks AS 3498 Water heaters and hot-water storage Boiling water dispenser N/A 2009 tanks Demand-activated heated water Hot water manual or sensor pumping system for use in a WMTS.464 Hot water manual or sensor-activated 2016 activated pumping system dedicated heated water recirculation pumping systems line. Plastics-bodied heated water circulating devices for use in a WMTS.472 Heated water system recirculation Heated water circulating device 2016 dedicated heated water recirculation device line. Devices specifically designed to WMTS.476 Heated Water Systems – Leak Leak protection device 2016 detect leaks and isolate the water protection device

Page | 14 Version: 2018 - 2

Product Scope/Application Specification Year

supply to heated water systems utilised in association with a safe tray. Manual variable time activated heated water pumping Heated water manual time system for use in a dedicated plumbing heated water No applicable specification. activated pump system supply re-circulation line. Metallic-bodied thermal switching valves intended to automatically switch the flow of water to one of two outlets, depending upon the temperature of the inlet water. Thermal switching valves are required to operate Thermal switching valve at— WMTS.481 Thermal switching valves 2016 a) continuous operating temperature not exceeding 85°C and 99°C under emergency conditions; and b) continuous working pressure not exceeding 1400 kPa. Water recovery device installed in the heated and cold water supply systems. The device transfers water as the Heated water system cold WMTS.475 Heated Water Systems – first flush in a heated water line to be stored and used 2016 water recovery device Cold water recovery device back in the cold water supply system or diverted to be used for other purposes.

Page | 15 Version: 2018 - 2

Valves - Isolation Product Scope/Application Specification Year

Metal and plastic bodied ball valves for installation between the reticulation water main and the property water meter in nominal sizes DN 15, 20, 25, 32, 40 and 50 at AS 4796 Water supply - Metal-bodied allowable operating pressures of PN 16 and 25 and and plastic (bodied ball valves for 2016 continuous operating temperatures not exceeding 60°C. property service connection) Products include service connection ball valves, service connection termination ball valves and the right angle meter assembly ball valves. Ball valve Miscellaneous type metallic and plastic bodied in-line AS/NZS 3718 Water supply - Tap 2005 valves for use in water supply systems. ware WMTS.012 In-line valves for use in Metallic and non-metallic in-line valves for use in water plumbing water supply systems – 2018 supply systems. Miscellaneous types metallic and non- metallic DN 6 to 100 one-piece and two piece metal-bodied in-line AS 5830.1 In-line ball valves for use in ball valves intended for non-buried installations, including plumbing water supply systems – 2012 2 way and 3 way valves. metal bodied WMTS.012 In-line valves for use in Metallic and non-metallic in-line valves for use in water plumbing water supply systems – 2018 supply systems. Miscellaneous types metallic and non- metallic PN 10 and 16 manually operated, resilient-seated, seal- AS 4795.1 Butterfly valves for Butterfly valve on-body wafer and tapped lugged butterfly valves in the waterworks purposes - Wafer and 2011 size range of DN 50 to 600 with a maximum operating lugged temperature of 40°C. PN 10, 16, 21 and 35 manually operated resilient-seated AS 4795.2 Butterfly valves for 2011 double-flanged butterfly valves with a maximum operating waterworks purposes Double flanged temperature of 40°C. Including manual actuators,

Page | 16 Version: 2018 - 2

Product Scope/Application Specification Year

gearboxes and standard spindle caps of the following nominal sizes: a) Seal on disc DN 300 to DN 2000. b) Seal in body DN 80 to DN 2000. c) Seal on body DN 80 to DN 2000. AS 1357.2 Valves primarily used in Isolating valves primarily intended for use in a heated Heated water isolating valves heated water systems – Control 2005 water service. valves Ductile iron PN 16 and 35 solid gate metal-bodied metal- AS 2638.1 Gate valves for waterworks seated gate valves with a maximum operating temperature 2011 purposes - Metal seated of 40°C. Ductile iron – PN 16 and 25 metal-bodied resilient-seated AS 2638.2 Gate valves for waterworks gate valves with a maximum operating temperature of 2011 Gate valve purposes – Resilient seated 40°C. Copper alloy - Metallic gate valves of nominal sizes DN 8 AS 1628 Water supply - Metallic gate, to 100 for use in heated and cold water applications where 1999 globe and non-return valves the operating temperature does not exceed 99°C. Metallic globe valves of nominal sizes DN 8 to 100 for use AS 1628 Water supply - Metallic gate, Globe valve in heated and cold water applications where the operating 1999 globe and non-return valves temperature does not exceed 99°C. Metallic-bodied PN 16, 21 and 35 hydraulically operated, AS 5081 Hydraulically operated Hydraulically operated diaphragm or piston-actuated, globe or piston-style, automatic control valves for 2008 automatic control valve automatic control valves of sizes DN 40 to 900 (inclusive) waterworks purposes with a maximum operating temperature of 40°C. Metallic and plastics-bodied valves that are actuated by Solenoid valve way of an electric solenoid valve and intended to be WMTS.030 Solenoid valves 2016 installed in the water service.

Page | 17 Version: 2018 - 2

Valves – Backflow prevention Product Scope/Application Specification Year

AS/NZS 2845.1 Water supply - Backflow prevention devices - A combination pressure limiting with dual check valve Materials, design and performance 2010 classified as PN 10, 12 or 16. Combination pressure limiting requirements with dual check valve (CV) Note: See NoD 2017/4.1 AS 1357.2 Valves primarily for use in Inlet pressure control valves primarily for use in a heated heated water systems – control valves 2005 water service. Note: See NoD 2017/4.1 Non-return valves that may be a separate valve or part of AS 1357.1 Valves primarily for use in Non-return valve a combination valve that is to be fitted to the inlet of a heated water systems Protection 2009 water heater. valves Metallic non-return valves of nominal sizes DN 8 to 100 for AS 1628 Water supply - Metallic gate, use in heated and cold water applications where the 1999 globe and non-return valves operating temperature does not exceed 99°C. Single check valve AS/NZS 2845.1 Water supply - A single check valve (testable) classified as PN 10, 12 or Backflow prevention devices - 2010 16. Materials, design and performance requirements AS/NZS 2845.1 Water supply - Backflow prevention devices Vented double check valve Vented double check valve classified as PN 10, 12 or 16. 2010 (Materials, design and performance requirements) AS/NZS 2845.1 Water supply - Vacuum breaker check valve Backflow prevention devices - Vacuum breaker check valve classified as PN 10, 12 or 16 2010 (VBCV) Materials, design and performance requirements AS/NZS 2845.1 Water supply - Reduced pressure zone A reduced pressure zone device classified as PN 10, 12 or Backflow prevention devices - 2010 device (RPZD) 16. Materials, design and performance requirements

Page | 18 Version: 2018 - 2

Product Scope/Application Specification Year

AS/NZS 2845.1 Water supply - Reduced pressure detector A reduced pressure detector assembly classified as PN Backflow prevention devices - 2010 assembly (RPDA) 10, 12 or 16 Materials, design and performance requirements AS/NZS 2845.1 Water supply - Pressure type vacuum A pressure type vacuum breaker classified as PN 10, 12 or Backflow prevention devices - 2010 breaker (PVB) 16. Materials, design and performance requirements AS/NZS 2845.1 Water supply - Hose connector vacuum A hose connection vacuum breaker classified as PN 10, Backflow prevention devices - 2010 breaker (HCVB) 12 or 16. Materials, design and performance requirements AS/NZS 2845.1 Water supply - Double check detector A double check detector assembly classified as PN 10, 12 Backflow prevention devices - 2010 assembly (DCDA) or 16. Materials, design and performance requirements AS/NZS 2845.1 Water supply - Backflow prevention devices - Dual check valve (Dual CV) A dual check valve classified as PN 10, 12 or 16. 2010 Materials, design and performance requirements AS/NZS 2845.1 Water supply - Backflow prevention devices - Double check valve (DCV) A double check valve classified as PN 10, 12 or 16. 2010 Materials, design and performance requirements AS/NZS 2845.1 Water supply - Dual check valve with A dual check valve with intermediate vent classified as PN Backflow prevention devices - 2010 intermediate vent (Du CV) 10, 12 or 16. Materials, design and performance requirements AS/NZS 2845.1 Water supply - Dual check valve with A dual check valve with atmospheric port classified as PN Backflow prevention devices - 2010 atmospheric port (DCAP) 10, 12 or 16. Materials, design and performance requirements

Page | 19 Version: 2018 - 2

Product Scope/Application Specification Year

AS/NZS 2845.1 Water supply - Beverage dispenser dual A hose connection vacuum breaker classified as PN 10, Backflow prevention devices - check valve with atmospheric 2010 12 or 16. Materials, design and performance port (BDDC) requirements AS/NZS 2845.1 Water supply - Atmospheric vacuum breaker An atmospheric vacuum breaker classified as PN 10, 12 or Backflow prevention devices - 2010 (AVB) 16. Materials, design and performance requirements AS/NZS 2845.1 Water supply - Anti-spill pressure vacuum A spill-resistant pressure vacuum breaker classified as PN Backflow prevention devices - 2010 breaker (APVB) 10, 12 or 16. Materials, design and performance requirements Non-return reflux valves of nominal sizes DN 8 to 100 for AS 1628 Water supply - Metallic gate, use in heated and cold water applications where the 1999 globe and non-return valves operating temperature does not exceed 99°C. Metal-bodied flanged non-return valves (swing check and tilting disc types) for use in water supply and pressure systems (swing check only) suitable for operation in both horizontal and vertical positions. Includes Class 16 and 35 valves in the size range DN 80 to 750, inclusive, with the maximum temperature of the medium flowing through the valve not exceeding 60°C. Products Non-return reflux valve AS/NZS 4794 Non-return valves - include:Non-return, free-acting valve, Non-return valve 2001 Swing check and tilting disc with extended hinge pin suitable for position indication, micro-switches, counterweight lever arm and counterweight.Non-return valve fitted with position indicator and/or counterweight lever arm and counterweight. Counterweight lever and counterweight for retrofit to valve with extended hinge pins. Non-return valve with resilient seated disc. PVC-U (Polyvinyl Chloride Unplasticised) and ABS WMTS.006 Reflux Valves - Sewerage 2014 (Acrylonitrile Butadiene Styrene) plastics bodied reflux

Page | 20 Version: 2018 - 2

Product Scope/Application Specification Year

valves of nominal sizes DN 100 to 600 intended for waste water.

Page | 21 Version: 2018 - 2

Valves – General Product Scope/Application Specification Year

Expansion control valve Expansion control valves primarily intended for use in AS 1357.1 Valves primarily for use in warm and heated water systems operating at a: heated water systems Protection a) Continuous operating temperatures not exceeding valves 2009 85°C and 99°C in emergency conditions; and b) Continuous working pressure not exceeding 1400 kPa. Note: See NoD 2017/4.1 Metallic-bodied valves that are connected to the water priming valve supply system and primarily utilised for the priming of WMTS.420 Trap-priming valves 2016 sanitary traps. AS 1172.2 Water closets (WCs) Flushing valves and devices intended for use with urinals Flushing devices and cistern inlet and and water closet pans of all types, including: outlet valves Flushing valve a) flushing valves for mains supply incorporating air gap 2014

disconnections (manual or sensor operated; and

b) flushing valves for use with break tank supply. Note: See NoD 2017/4.1 Active float control valves for use in water supply systems where the normal working temperature does not exceed 95°C and the continuous working pressure extends up to a AS 1910 Water supply - Float control Float control valve maximum of 1.4 MPa for a range of nominal sizes from DN 2004 valves for use in hot and cold water 6 to 80. Note: Water closet cistern flushing valves are outside of the scope. Inlet pressure control valves primarily intended for use in a AS 1357.2 Valves primarily for use in 2005 heated water service. heated water systems - Control valves Pressure ratio valve Pressure ratio valves greater than DN 50 that are intended WMTS.052 Metallic-bodied inlet for use in cold water systems at continuous working pressure control valves greater than 2016 pressures not exceeding 1400 kPa. DN 50 AS 1357.2 Valves primarily for use in Inlet pressure control valve Inlet pressure control valves primarily intended for use in a 2005 heated water service. heated water systems - Control valves

Page | 22 Version: 2018 - 2

Product Scope/Application Specification Year

AS 1357.2 Valves primarily for use in Inlet pressure control valves primarily intended for use in a 2005 heated water service. heated water systems - Control valves Pressure-reducing valve Pressure-reducing valves greater than DN 50 that are WMTS.052 Metallic-bodied inlet primarily intended for use in cold water systems at pressure control valves greater than 2016 continuous working pressures not exceeding 1400 kPa. DN 50 AS 1357.2 Valves primarily for use in Inlet pressure control valves primarily intended for use in a 2005 Pressure-limiting valve heated water service. heated water systems - Control valves Pressure-reducing valves greater than DN 50 that are WMTS.052 Metallic-bodied inlet primarily intended for use in cold water systems at pressure control valves greater than 2016 continuous working pressures not exceeding 1400 kPa. DN 50 Pressure / temperature AS 1357.1 Valves primarily for use in Temperature and pressure relief valves within the range of relief valve heated water systems Protection 2009 DN 15 to 50. Note: See NoD 2017/4.1 valves WMTS.453 Heated water systems – Valves used in heated water recirculation systems. 2016 Thermostatic circulation valve Recirculation valve Valves that are utilised to control the temperature in WMTS.468 Hot water systems – heated water recirculation systems through balancing of 2016 Recirculation valves the flow. AS 1357.2 Valves primarily used in Primary temperature control Primary temperature control valves primarily intended for heated water systems – Control 2005 valve use in a heated water service. valves AS 4032.2 Water supply - Valves for Tempering valves of nominal sizes not larger than DN 32 the control of hot water supply and end-of-line temperature-actuated devices of nominal temperatures Tempering valves and size not larger than DN 25, for use with heated water: end-of-line temperature-actuated Tempering valve a) at continuous operating temperature not exceeding 2005 devices. 85°C and 99°C under emergency conditions; and

b) a continuous working pressure not exceeding 1400

kPa. Note: See NoD 2017/4.1

Page | 23 Version: 2018 - 2

Product Scope/Application Specification Year

AS 4032.1 Water supply - Valves for Metallic-bodied thermostatic mixing valves of nominal the control of heated water supply sizes not larger than DN 50 for use with heated water temperatures Thermostatic mixing Thermostatic mixing valve 2005 exceeding 90°C; and heated and cold water working valves pressures not exceeding 1400 kPa. Note: See NoD 2017/4.1 Thermosiphon arrestor valves primarily intended for use in AS 1357.2 Valves primarily for use in Thermosiphon arrestor valve 2005 a heated water service. heated water systems - Control valves Vacuum relief valves not intended to prevent backflow or AS 1357.2 Valves primarily for use in Vacuum relief valve 2005 back-siphonage. heated water systems - Control valves SA TS 100 Vacuum WC pans, Vacuum interface valves intended for use with vacuum vacuum urinals and interface valves Vacuum interface valve 2018 drainage systems. intended for use with vacuum drainage systems and designs Pressure attenuator devices for use in sanitary plumbing Pressure attenuator vent and drainage systems intended for operation within the WMTS.463 Pressure attenuator 2015 valve temperature range of 0°C to 40°C Air relief vent valve No applicable specification Air admittance valves including those that are integral to a Air admittance (induct/one AS/NZS 4936 Air admittance valves fixture trap where the air temperature is between 0°C and 2002 way) vent valve (AAV's) 60°C.

Page | 24 Version: 2018 - 2

Fire service Product Scope/Application Specification Year

Fire sprinkler heads for domestic applications incorporated WMTS.486 Fire sprinkler heads for Fire sprinkler heads 2016 in a domestic water supply in buildings. domestic applications Flanged ductile cast iron spring hydrant valves with AS 3952 Water supply - Spring resilient seat for waterworks purposes. Class 16 valves of Spring hydrants hydrant valve for waterworks 2002 nominal size DN 80 with either DN 80 or DN 100 flange purposes with a maximum working temperature of 60°C.

Page | 25 Version: 2018 - 2

Jointing products Product Scope/Application Specification Year

Jointing material utilized in the installation of water supply Brazing alloy WMTS.014 Jointing materials 2016 plumbing systems. Jointing material utilized in the installation of water supply Solder WMTS.014 Jointing materials 2016 plumbing systems. AS 1646 Elastomeric seals for For use in water, sewerage and drainage systems. 2007 waterworks purposes Thermoplastic elastomers and vulcanizates for moulding seals used in joints of - AS 1646.4 Elastomeric seals for a) thermoplastic piping systems for non-pressure waste waterworks purposes Material discharge (intermittent flow up to 95°C) inside requirements for pipe joint seals used buildings; 2005 in water and wastewater applications - b) thermoplastic piping systems for non-pressure Elastomeric seals and Thermoplastic elastomers and underground drainage and sewerage (continuous flow gaskets vulcanizates up to 45°C and intermittent flow up to 95°C); and

c) thermoplastic rainwater piping systems. Unreinforced elastomeric and reinforced and unreinforced compressed non-asbestos fibre flange gaskets and elastomeric O-rings suitable for jointing flanges and other flange standards, for— WSA 109 Flange gaskets and o-rings 2011 a) cold potable water supply (up to 40°C); and b) drainage and sewerage systems (continuous flow up to 45°C and intermittent flow up to 95°C). Jointing material utilized in the installation of water supply Lubricant WMTS.014 Jointing materials 2016 plumbing systems. Solvent cements and priming fluids used in the jointing of- AS/NZS 3879 Solvent cements and a) tapered/interference and parallel/no or low interference priming fluids for PVC (PVC-U and Priming fluid 2011 fit polyvinyl chloride (PVC-U and PVC-M) pressure and PVC-M) and ABS and ASA pipes and non-pressure piping systems; fittings

Page | 26 Version: 2018 - 2

Product Scope/Application Specification Year

b) acrylonitrile butadiene styrene (ABS) pressure and non-pressure piping systems; and c) ABS and acrylonitrile styrene acrylate (ASA) fittings for non-pressure drainage applications with PVC-U pipes. Solvent cements and priming fluids used in the jointing of AS/NZS 3879 Solvent cements and Solvent cement for polyvinyl tapered/interference and parallel/no or low interference fit priming fluids for PVC (PVC-U and 2011 chloride (PVC-U and PVC-M) polyvinyl chloride (PVC-U and PVC-M) pressure and non- PVC-M) and ABS and ASA pipes and pressure piping systems. fittings Solvent cement for Solvent cements and priming fluids used in the jointing of- AS/NZS 3879 Solvent cements and acrylonitrile butadiene a) acrylonitrile butadiene styrene (ABS) pressure and priming fluids for PVC (PVC-U and styrene (ABS) and non-pressure piping systems; and 2011 PVC-M) and ABS and ASA pipes and acrylonitrile styrene acrylate b) ABS and acrylonitrile styrene acrylate (ASA) fittings for fittings (ASA) non-pressure drainage applications with PVC-U pipes. Jointing material utilized in the installation of water supply Sealant (general) WMTS.014 Jointing materials 2016 plumbing systems. Jointing material utilized in the installation of water supply Thread sealant WMTS.014 Jointing materials 2016 plumbing systems. Roll-grooved jointing system that incorporates a ductile WMTS.042 Roll-grooved jointing iron body coupling with included elastomeric seal to join 2016 systems copper or stainless steel tubes and metallic fittings. Metallic body pipe fittings and connectors for use with Roll-grooved fittings copper tube, stainless steel pipe and tube and adaptor fittings for connection to other pipe materials in water AS 3688 Water supply and gas supplies with a maximum operating pressure does not systems – metallic fittings and end 2016 exceed 2,100 kPa. connectors Note: Product testing specific to gas products are not required. Note: See NoD 2017/4.1 Plastic-bodied transition couplings intended to join PE, PB, AS 5200.458 Plumbing and drainage Transitional fittings PEX, PP, PVC, ABS, copper, ductile iron, cast iron, lead, products - Universal plastic-bodied 2008 stainless steel and galvanized steel pipes for cold water transition couplings

Page | 27 Version: 2018 - 2

Product Scope/Application Specification Year

applications (with a maximum operating pressure of 1250 kPa at 20°C) to each other and to themselves (i.e., PE to copper), for pipe/tube sizes up to 110 mm outside diameter.

Page | 28 Version: 2018 - 2

Pipes – Metallic Product Scope/Application Specification Year

Round seamless copper alloy tubes intended for use in pressure and non-pressure plumbing and drainage applications as follows: AS 3795 Copper alloy tubes for Copper alloy pipe a) Brass tubes intended primarily for sanitary plumbing 1996 plumbing and drainage applications services; and b) Copper nickel tubes intended primarily for water services. Round seamless copper tubes intended for use in pressure and non-pressure plumbing and drainage AS 1432 Copper tubes for plumbing, Copper pipe applications. 2004 gasfitting and drainage applications Note: Product testing specific to gas products are not required. Ductile iron pressure pipes centrifugally cast in moulds, and ductile iron fittings of nominal sizes up to and including AS/NZS 2280 Ductile iron pipes and Ductile Iron pipe DN 750. Pipes intended primarily for conveying water 2014 fittings under pressure, but may be used for conveying or other liquids. AS 5200.053 Stainless steel pipes Stainless steel pipes and tubes in the range of DN 15 to and tubes for pressure applications 2008 DN 300 used in hot and cold water supply systems. Stainless steel pipe Note: See NoD 2017/4.1 AS 3495 Authorization requirements Pipes for non-pressure applications in the operating for plumbing products - Stainless steel 1997 temperature range from - 40 C to 100 C. non-pressure pipes and fittings Composite piping system consisting of a stainless steel outer casing bonded to an inner layer of polypropylene WMTS.473 Stainless steel/nano- Stainless steel/nano-antibiotic (PP-R), which includes a contact layer of nano-antibiotic antibiotic PP-R pipe systems for water 2016 PP-R pipe pipe material for use in cold and heated water supply systems supply applications at continuous operating temperatures up to 80°C with

Page | 29 Version: 2018 - 2

Product Scope/Application Specification Year

short exposures up to 100°C and continuous working pressures not exceeding 1.4 MPa. Cast iron pipeline components used for the construction of discharge systems for buildings and of drains, normally as Cast Iron pipe EN 877 Cast iron pipes and fittings 1999 gravity systems. Nominal sizes are inclusive of DN 40 to 600. Cast grey iron (flake graphite) non-pressure pipes and AS 1631 Cast grey and ductile iron Grey cast iron pipe fittings up to nominal size DN 300, intended to be used 2004 non-pressure pipes and fittings where the internal working pressure is negligible. Aluminium alloy piping for the conveyance of water in sizes ranging from DN 15 to DN 150, with an internal WMTS.491 Aluminium alloy piping plastics lining for above-ground applications. For use at Aluminium alloy pipe system with plastics lining for 2016 operating temperatures up to 70°C, operating pressures plumbing water services applications (inclusive surge) of 1920 kPa and a maximum allowable site test pressure of 2000 kPa.

Page | 30 Version: 2018 - 2

Pipes – Plastic Product Scope/Application Specification Year

Acrylonitrile butadiene styrene (ABS) compounds (ABS AS/NZS 3518 Acrylonitrile butadine 120, ABS 140, ABS 160 and ABS 180), pipes for the styrene (ABS) compounds, pipes and 2013 conveyance of liquids under pressure. fittings for pressure applications Acrylonitrile butadiene Acrylonitrile butadiene styrene (ABS) piping system for the styrene (ABS) pipe WMTS.507 Acrylonitrile Butadiene conveyance of water under pressure for use at continuous Styrene (ABS) Piping System with 2014 operating temperatures up to 70°C, allowable operating Stainless Steel Lining for Plumbing pressures up to 1600 kPa in sizes ranging from DN 20 to Water Service Applications 110 for use with ABS fittings. AS/NZS 2492 Cross-linked Cross-linked polyethylene pipes for the conveyance of Cross-linked polyethylene polyethylene (PE-X) pipes for fluids under pressure including: water, wastewater and 2007 pipe pressure applications slurries. Note: See NoD 2017/4.1 AS 4176.1 Multilayer pipes for pressure applications - Multilayer Multilayer piping systems intended to be used for heated piping systems for hot and cold water 2010 and cold water installations inside buildings. plumbing applications - General Macro composite pipe Note: See NoD 2017/4.1 AS 4176.2 Multilayer piping systems Multilayer piping systems intended to be used for heated for hot and cold water plumbing 2010 and cold water installations inside buildings. applications – pipes Note: See NoD 2017/4.1 Polybutylene pipe of pressure class PN16 up to 28 mm AS/NZS 2642.2 Polybutylene (PB) nominal outside diameter for heated and cold water plumbing pipe systems Polybutylene Polybutylene (PB) pipe applications. (PB) pipe for hot and cold water 2008 Note: This does not apply to pipes with a wall thickness of applications less than 1.6 mm. Note: See NoD 2017/4.1 Polyethylene (PE) pipe Polyethylene pipes for the conveyance of fluids under AS/NZS 4130 Polyethylene (PE) pressure including, but are not restricted to, water, pipes for pressure applications 2009 wastewater, slurries.

Page | 31 Version: 2018 - 2

Product Scope/Application Specification Year

AS/NZS 4401 Plastics piping systems Solid-wall polyethylene (PE) pipes for soil and waste for soil and waste discharge (low and discharge (low and high temperature) of nominal sizes DN high temperature) inside buildings - 32 to DN 315 for installation inside buildings 2006 Polyethylene (PE) Note: Pipework intended to be buried is outside of the

scope. Note: See NoD 2017/4.1 Polyethylene (PE) pipes greater than DN 100 for sewerage and drainage applications, above and below ground, inside AS/NZS 5065 Polyethylene and and outside of buildings, and intended to be used where polypropylene pipes and fittings for 2005 the pipeline is operating under gravity flow and the drainage and sewerage applications operating pressure is low. It includes plain and structured wall pipes. Note: See NoD 2017/4.1 ISO 15874-1 Plastic piping systems Polypropylene (PP) piping systems intended to be used for for hot and cold water installations – 2013 heated and cold water installations within buildings. Polypropylene (PP) - General. ISO 15874.2 Plastics piping systems Polypropylene (PP) for piping systems intended to be used for hot and cold water installations – 2013 for heated and cold water installations within buildings. Polypropylene (PP) – Pipes Note: See NoD 2017/4.1 Polypropylene (PP) pipe Solid-wall polypropylene (PP) pipes for soil and waste AS/NZS 7671 Plastics piping systems discharge (low and high temperature) inside buildings. for soil and waste discharge (low and 2010 Note: Pipework intended to be buried is outside of the high temperature) inside buildings scope. Polypropylene (PP) pipes greater than DN 100 for AS/NZS 5065 Polyethylene and sewerage and drainage applications intended to be used polypropylene pipes and fittings for where the pipeline is operating under gravity flow and the drainage and sewerage applications 2005 operating pressure is low. It includes plain and structured wall pipes. Note: See NoD 2017/4.1 AS/NZS 1477 PVC pipes and fittings Polyvinyl chloride (PVC) pipe PVC pipes for pressure applications. 2017 for pressure applications

Page | 32 Version: 2018 - 2

Product Scope/Application Specification Year

PVC-U pipes for sewer, drain, waste and vent applications AS/NZS 1260 PVC-U pipes and intended to be used where the pipeline is operating under fittings for drain, waste and vent 2017 gravity flow and the operating pressure is low, both plain applications and structured wall pipes. Pipes made of oriented unplasticized polyvinyl chloride AS 4441 Oriented PVC (PVC-O) 2017 (PVC-O). pipes for pressure applications Pipes of PVC-M for the conveyance of water and AS 4765 Modified PVC (PVC-M) 2017 wastewater under pressure. pipes for pressure applications AS 5082.1 Polybutylene (PB) plumbing pipe systems - Metric series Metric polybutylene (PB) pipe Polybutylene pipe for heated and cold water applications. 2007 - Metric polybutylene (PB) pipes for hot and cold water applications AS 3571.1 Plastics piping systems - Glass-reinforced thermoplastics (GRP) pipes based on Glass-reinforced thermoplastics unsaturated polyester (UP) resin for pressure and non- (GRP) systems based on unsaturated 2009 Glass-filament-reinforced pressure drainage and sewerage applications polyester (UP) resin - Pressure and thermosetting plastic (GRP) non-pressure drainage and sewerage pipe AS 3571.2 Plastics piping systems - Glass-reinforced thermoplastics (GRP) systems based on Glass-reinforced thermoplastics unsaturated polyester (UP) resin for pressure and non- (GRP) systems based on unsaturated 2009 pressure water supply applications. polyester (UP) resin - Pressure and non-pressure water supply Noise reduction pipes made of a compound of WMTS.508 Plastics piping systems Plastic pipe with noise polypropylene and inert mineral additives for waste and for soil and waste discharge – with 2013 reduction drainage installations with intermittent operating noise reduction characteristics temperatures up to 95°C.

Page | 33 Version: 2018 - 2

Pipes – Other Product Scope/Application Specification Year

Cured-in-place pipes (CIPP) used for the rehabilitation of above and below ground drainage and sewerage WMTS.518 Rehabilitation of existing Cured in Place Pipe (CIPP) pipelines. The process may be applied to metallic and non- non-Pressure Pipelines by the use of 2017 metallic non-pressure piping systems in pipe sizes DN 40 Cured In Place Pipe (CIPP) to 1000. Fibre-reinforced concrete pipes using standard curing, AS 4139 Fibre reinforced concrete Fibre-reinforced cement pipe including autoclaving, for the conveyance of non-pressure 2003 pipes and fittings gravity water supply, waste water and sewage drainage. Perforated pipes made from vitrified clay with or without EN 295 Vitrified clay pipe systems for Vitrified clay pipe sockets for the construction of french drains, land drains 2013 drains and sewers and drainage of waste tips Epoxy barrier coating system used for lining of metallic WMTS.511 Epoxy barrier coating Epoxy coating for lining of cold and heated water pressurised piping systems utilised system for use in water supply 2014 metallic piping for drinking water supply. The system may be applied to applications metallic substrates in pipe sizes DN 15 to 300.

Page | 34 Version: 2018 - 2

Fittings – Metallic Product Scope/Application Specification Year

Metallic body pipe fittings and connectors for use with copper tube, stainless steel pipe, stainless steel tube and AS 3688 Water supply and gas adaptor fittings for connection to other pipe materials in systems - Metallic fittings and end 2016 water supply systems. connectors Note: Product testing specific to gas products are not required. Note: See NoD 2017/4.1 Copper alloy fittings Cast, hot-pressed, shell-moulded, and tubular fittings with AS 3517 Capillary fittings of copper socket/spigot capillary connection ends for use in non- and copper alloy - Non-pressure 2007 pressure sanitary plumbing applications with the nominal sanitary plumbing applications sizes from DN 32 to 225. Copper alloy waste fittings including traps, gullies, waste AS 1589 Copper and copper alloy 2001 outlets, gratings and connectors. waste fittings Copper waste fittings including traps, gullies, waste AS 1589 Copper and copper alloy 2001 outlets, gratings and connectors. waste fittings Metallic body fittings and connectors for use with copper tube, stainless steel pipe, stainless steel tube and adaptor AS 3688 Water supply and gas fittings for connection to other pipe materials in water systems - Metallic fittings and end 2016 supply. connectors Copper fittings Note: Product testing specific to gas products are not

required. Note: See NoD 2017/4.1 Cast, hot-pressed, shell-moulded, and tubular fittings with AS 3517 Capillary fittings of copper socket / spigot capillary connection ends for use in non- and copper alloy - Non-pressure 2007 pressure sanitary plumbing applications with the nominal sanitary plumbing applications sizes from DN 32 to 225. Copper and copper alloy waste fittings for use in sanitary Copper and copper alloy AS 1589 Copper and copper alloy plumbing installations including traps, gullies, waste 2001 gullies and expansion joints waste fittings outlets, gratings, and connectors. Fittings intended primarily for use with water supply AS/NZS 2280 Ductile iron pipes Ductile Iron fittings 2014 pressure pipes. and fittings

Page | 35 Version: 2018 - 2

Product Scope/Application Specification Year

AS 3495 Authorization Stainless steel fittings for applications in the operating requirements for plumbing products temperature range from - 40°C to 100°C. - Stainless steel non-pressure 1997 pipes and fittings Stainless steel fittings Metallic body pipe fittings and connectors for use with AS 3688 Water supply—Metallic stainless steel pipe, stainless steel tube and adaptor fittings and end connectors fittings for connection to other pipe materials in water 2016

supply systems where the maximum operating pressure Note: See NoD 2017/4.1 does not exceed 2,100 kPa. Composite piping system consisting of a stainless steel outer casing bonded to an inner layer of polypropylene (PP-R), which includes a contact layer of nano-antibiotic WMTS.473 Stainless steel/nano- Stainless steel/nano-antibiotic material intended for use in cold and heated water supply antibiotic PP-R pipe systems for 2016 PP-R pipe fittings systems at continuous operating temperatures up to 80°C water supply applications with short exposures up to 100°C and continuous working pressures not exceeding 1.4 MPa. Cast grey iron (flake graphite) non-pressure fittings up to AS 1631 Cast grey and ductile iron nominal size DN 300 and intended to be used where the 1994 non-pressure pipes and fittings internal working pressure is negligible Cast Iron fittings Cast iron pipeline components (including gullies) used for the construction of discharge systems for buildings and of EN 877 Cast iron pipes and fittings 1999 drains, normally as gravity systems of nominal sizes of DN 40 to 600 (inclusive). Cast grey iron (flake graphite) non-pressure fittings (including gullies) up to nominal size DN 300 and intended AS 1631 Cast grey and ductile iron Grey cast iron fittings 1994 to be used where the internal working pressure is non-pressure pipes and fittings negligible. Aluminium alloy fittings for the conveyance of water for WMTS.491 Aluminium alloy piping Aluminium alloy fittings 2016 above-ground applications for use at continuous operating system with plastics lining for

Page | 36 Version: 2018 - 2

Product Scope/Application Specification Year

temperatures up to 70°C and allowable operating plumbing water services pressures of 1920 kPa in sizes ranging from DN 15 to 150, applications with an internal plastics lining for use with— a) aluminium alloy fittings with an internal plastics lining and mechanical compression joint system in sizes ranging from DN 15 to 50; and b) roll-grooved system utilizing polymeric-coated ductile iron couplings and associated fittings with rigid elastomeric sealed joints in sizes ranging from DN 50 to 150. Metal-banded flexible either with or without metal shear rings to be used in below or above ground low-pressure systems which convey water or waste water designed for jointed items having the same or similar nominal internal AS/NZS 4327 Metal-banded Flexible couplings diameters. flexible couplings for low-pressure 1995 Note: Spigot and socket joints with elastomeric seals and applications adaptor flexible couplings designed for jointed items having significantly different diameters are outside of the scope. Mechanical clamps including: a) Type R clamps primarily for ductile iron, grey cast iron, AS 4181 Repair and off-take steel, asbestos cement, copper and reinforced Repair clamps clamps for water industry 2013 concrete; and purposes. b) Type F clamps primarily for PVC-O, PVC-M, PVC-U and GRP. Semi-flexible metallic hose assemblies from DN 20 to DN Semi-flexible metallic hose 400 with a working pressure of 1200 to 2500 kPa for use WMTS.520 Semi-Flexible Metallic 2016 assemblies with above ground heated water up to 90°C and cold- Hose Assemblies water supplies in accessible and not submerged locations.

Page | 37 Version: 2018 - 2

Product Scope/Application Specification Year

Flexible assemblies constructed from annularly corrugated stainless steel tube of up to DN 50, for use at continuous WMTS.489 Stainless steel flexible Stainless steel flexible operating temperatures up to 80°C and continuous assemblies for pumping 2016 assemblies working pressures of at least 1400 kPa intended to be applications installed above-ground and accessible locations. AS/NZS 4129 Fittings for Plastics or metal tapping saddles for assembly on polyethylene (PE) pipes for 2008 polyethylene (PE) pressure pipes. pressure applications PN 16 mechanical tapping bands for the connection of property service pipes to reticulation water mains including tapping bands, with and without electrical insulation, for Mechanical Tapping bands mechanical connection to standard water mains. The AS/NZS 4793 Mechanical tapping nominal operating temperature is 0°C to 40°C. The bands for 2009 nominal size range of DN 80 to 450 with outlet sizes waterworks purposes ranging from DN 15 to 50. Note: Solvent cemented PVC tapping bands and tapping bands for polyethylene water mains are outside of the scope.

Page | 38 Version: 2018 - 2

Fittings – Plastic Product Scope/Application Specification Year

Solid-wall acrylonitrile-butadiene-styrene (ABS) fittings for Acrylonitrile butadiene soil and waste discharge (low and high temperature) inside ISO 7682 Plastics piping systems styrene (ABS) fittings buildings, designed for jointing by means of elastomeric 2003 for soil and waste discharge sealing rings, solvent cementing or integral dual-purpose sockets. AS 2537.2 Mechanical jointing fittings for use with crosslinked polyethylene (PE-X), Part 2: Cross-linked polyethylene Fittings for use with crosslinked polyethylene (PE-X) for Plastics piping systems for hot and 2011 (PE-X) fittings pressure heated and cold water applications. cold water installations – Crosslinked polyethylene(PE-X) – Fittings Note: See NoD 2017/4.15 AS 4176.3 Multilayer piping Multilayer piping systems for heated and cold water systems for hot and cold water 2010 installations inside buildings. plumbing applications – Fittings Note: See NoD 2017/4.1 Macro composite fittings AS 4167.1 Multilayer pipes for pressure applications - Multilayer Multilayer piping systems for heated and cold water piping systems for hot and cold 2010 installations inside buildings. water plumbing applications - General AS/NZS 2642.3 Polybutylene (PB) plumbing pipe systems Mechanical Mechanical jointing fittings suitable for use as fixed joints jointing fittings for use with Polybutylene (PB) fittings 2008 with polybutylene plumbing pipes. polybutylene (PB) pipes for hot and cold water applications. Note: See NoD 2017/4.1

Page | 39 Version: 2018 - 2

Product Scope/Application Specification Year

AS/NZS 4129 Fittings for Fittings to be used with polyethylene pipe for the polyethylene (PE) pipes for 2008 conveyance of water and other fluids. pressure applications AS/NZS 4401 Plastics piping systems for soil and waste Solid-wall polyethylene (PE) fittings for soil and waste discharge (low and high 2006 discharge (low and high temperature) of DN 32 to 100. temperature) inside buildings - Polyethylene (PE) fittings Polyethylene (PE)

Note: See NoD 2017/4.1

AS/NZS 5065 Polyethylene and Polyethylene (PE) fittings greater than DN 100 for polypropylene pipes and fittings for sewerage and drainage applications, intended to be used drainage and sewerage where the pipeline is operating under gravity flow and the 2005 applications operating pressure is low. Including both plain and

structured wall fittings. Note: See NoD 2017/4.1 AS/NZS 5065 Polyethylene and Polypropylene (PP) fittings greater than DN 100 for polypropylene pipes and fittings for sewerage and drainage applications, intended to be used drainage and sewerage where the pipeline is operating under gravity flow and the 2005 applications operating pressure is low. Including both plain and

structured wall pipes and fittings. Note: See NoD 2017/4.1 Polypropylene (PP) fittings for soil and waste discharge Polypropylene (PP) fittings (low and high temperature). This is applicable to PP AS/NZS 7671 Plastics piping fittings, and assemblies fittings, intended to be used for systems for soil and waste soil and waste discharge pipework for the conveyance of 2010 discharge (low and high domestic waste waters (low and high temperature) and temperature) inside buildings associated ventilation pipework. Fittings for jointing by means of elastomeric sealing rings or by butt fusion. Polypropylene (PP) piping systems intended to be used for ISO 15874.3 Plastic piping systems 2013 heated and cold water installations within buildings. for hot and cold water installations

Page | 40 Version: 2018 - 2

Product Scope/Application Specification Year

– Polypropylene (PP) – Fittings Note: See Nod 2017/4.1 ISO 15874-1 Plastic piping Polypropylene (PP) piping systems intended to be used for systems for hot and cold water 2013 heated and cold water installations within buildings. installations – Polypropylene (PP) – General PVC-U fittings (including gullies and expansion joints) for sewer, drain, waste and vent applications, intended to be AS/NZS 1260 PVC-U pipes and used where the pipeline is operating under gravity flow and fittings for drain, waste and vent 2016 Polyvinyl chloride (PVC) the operating pressure is low. Including plain and applications fittings structured wall fittings. PVC fittings for pressure applications where not exposed AS/NZS 1477 PVC pipes and 2017 to direct sunlight. fittings for pressure applications Mechanical and fusion jointing fittings suitable for use as fixed joints with polybutylene pipes of the following types: AS 5082.2 Polybutylene (PB) Metric polybutylene (PB) a) Socket weld fittings. plumbing pipe systems - Metric 2007 fittings b) Electrofusion fittings. series - Mechanical and fusion c) Mechanical fittings. jointing systems d) Fittings with incorporated inserts. AS 3571.1 Plastics piping systems - Glass-reinforced thermoplastics Glass-reinforced thermoplastics (GRP) systems based on (GRP) systems based on unsaturated polyester (UP) resin. Used for pressure and 2009 unsaturated polyester (UP) resin - Glass-filament-reinforced non-pressure drainage and sewerage applications. Pressure and non-pressure thermosetting plastic (GRP) drainage and sewerage fittings AS 3571.2 Plastics piping systems Glass-reinforced thermoplastics (GRP) systems based on - Glass-reinforced thermoplastics unsaturated polyester (UP) resin. For use in pressure and 2009 (GRP) systems based on non-pressure water supply applications. unsaturated polyester (UP) resin -

Page | 41 Version: 2018 - 2

Product Scope/Application Specification Year

Pressure and non-pressure water supply Noise reduction fittings made of a compound of WMTS.508 Plastics piping systems Plastic fittings with noise polypropylene and inert mineral additives for use at for soil and waste discharge – with 2013 reduction intermittent operating temperatures up to 95°C. noise reduction characteristics A plastic waste outlet which may incorporate components Plastic waste outlets AS 2887 Plastic waste fittings 1993 made from either plastic or other materials. Moulded or fabricated plastic Plastic fixture traps waste fittings suitable for receiving intermittent liquid AS 2887 Plastic waste fittings 1993 discharges at temperatures not exceeding 95°C. DN 80 or DN 100 plastics-bodied fitting that is utilised as Soil waste dump fittings WMTS.482 Soil waste dump fitting 2016 soil waste dump point for mobile toilet waste disposal. Plastic bodied couplings up to DN 225 with included Plastic bodied flexible WMTS.519 Plastic Bodied Flexible elastomeric element that provides limited flexibility and are 2016 couplings Coupling utilised in non-pressure rigid pipeline systems. Plastics bodied fittings of nominal sizes up to DN 225 with WMTS.055 Plastic fittings – Plastic bodied fitting with intermediate flexible joints for sewer or drain applications Connectors with flexible 2008 intermediate flexible joints intended to be used where the pipeline is operating under intermediate joints for drainage and gravity flow and the operating pressure is low. sewerage applications Injected moulded offset pan connectors. WMTS.517 Offset pan connectors 2016 Note: See NoD 2016/2.0 Moulded or fabricated plastic waste fittings used to convey Offset pan connectors liquids not exceeding 95°C from a fixture to discharge AS 2887 Plastic waste fittings 1993

pipework.

PVC-U fittings for sewer drain, waste and vent application AS/NZS 1260 PVC-U pipes and intended to be used where the pipeline is operating under fittings for drain, waste and vent 2017 gravity flow and the operating pressure is low. applications. Moulded or fabricated plastic waste fittings used to convey Plastic waste fitting liquids not exceeding 95°C from a fixture to discharge AS 2887 Plastic waste fittings 1993 pipework.

Page | 42 Version: 2018 - 2

Fittings – Other Product Scope/Application Specification Year

Fibre-reinforced concrete fittings using standard curing Fibre-reinforced cement AS 4139 Fibre reinforced concrete (including autoclaving), for the conveyance of gravity water 2003 fittings pipes and fittings supply, waste water and sewage drainage. Perforated fittings (including gullies, adaptors and connectors) made from vitrified clay with or without EN 295 Vitrified clay pipe systems Vitrified clay fittings 2013 sockets for the construction of french drains, land drains for drains and sewers and drainage of waste tips. Filter assemblies of nominal sizes DN 40 to 100, designed Odour control filters WMTS.483 Odour control filter 2017 to be installed in a sanitary drainage system. WMTS.040 Waste pipe connection Metallic and plastics bodied waste pipe outlets for sanitary Waste outlets outlets and gratings, separate or plumbing applications. 2016 integral WMTS.040 Waste pipe connection Metallic and plastics bodied waste gratings, separate or Waste gratings outlets and gratings, separate or 2016 integral for sanitary plumbing applications. integral Barrier type floor drain trap seal protection device for floor WMTS.522 Barrier type floor drain Barrier floor drain trap seals 2018 drain pipes of nominal sizes DN 40, 50, 80 and 100. trap seal protection devices Self-sealing trap Self-sealing devices of nominal sizes DN 32, 40 and 50. WMTS.047 Self-sealing devices 2016

Page | 43 Version: 2018 - 2

Shafts and pumping stations Product Scope/Application Specification Year

Unplasticized polyvinyl chloride (PVC-U), polypropylene (PP) and polyethylene (PE) plastics piping systems for EN 13598-1 Plastics piping systems Inspection shaft non-pressure underground drainage and sewerage. for non-pressure underground 2010 Specifications for ancillary fittings including shallow drainage and sewerage inspection chambers. The product is a prefabricated .These product are utilised for pumping waste when it is not practical to gravitate to the sewerage system. Prefabricated pumping station Product components may include; a pit which can be TBA manufactured in plastics, fibreglass or concrete with service lid,pumps, controllers, miscellaneous valves, pipework and fittings Appliances for the conveyance of soil and/or waste water Sanitary pumps and lifting from plumbing fixtures to the sanitary drainage system, TBA stations. which may incorporate a macerator PVC-U maintenance shaft comprising a fabricated or injection-moulded, or both, chamber jointed to an extruded AS/NZS 4999 PVC-U maintenance PVC riser intended for installation in sewerage systems 2006 shafts (up to DN 300) for transportation of sewage at atmospheric pressure and average service temperatures up to 25°C. Polypropylene (PP) access chambers / maintenance Maintenance shaft shafts comprising an injection-moulded chamber for jointing to extruded PVC-U sewers or drains and riser WMTS.509 Polypropylene Access shafts intended for installation in plumbing, sewerage and Chambers and Maintenance Shafts 2013 drainage systems (up to DN 225) for transportation of for Plumbing and Drainage sewage at atmospheric pressure and the operating temperature is not greater than a nominal 25°C.

Page | 44 Version: 2018 - 2