RE-301 Rotary Evaporator

Total Page:16

File Type:pdf, Size:1020Kb

RE-301 Rotary Evaporator Important Notice 1. Please read this manual carefully and obey all safety and warning notices. Ensure that every operator reads this manual. 2. Power connection must have reliable ground and ensure the casing safety grounding. 3. Be careful when dismounting and cleaning the glassware in case of damage. 4. The device must be installed at a suitable place. Do not install the device in the vicinity of highly inflammable or explosive substances. 5. Wear the appropriate protective clothing when working on the device (protective glasses and, if necessary, safety gloves). 6. To the precious solutions, operator should do simulation experiment first to confirm the equipment can meet the experimental request, and then turn to normal use. 7. Heating bath must first be filled with water, then power-on. Turn power off when finish using it. 8. Electrical parts can not be soaked. - 1 - - 2 - Content Important Notice.......................................................... 1 Brief Description..........................................................5 Advantages...................................................................6 Technical Data..............................................................7 Installation....................................................................8 Operation....................................................................10 I. Operation procedure..................................................10 II. Considerations......................................................... 14 Maintenance............................................................... 15 After-sale Service.......................................................16 - 3 - Brief Description - 4 - A rotary evaporator is a specially designed instrument for the evaporation of solvent under vacuum. The evaporator consists of a heating bath with a rotating flask, in which the liquid is distributed as a thin film over the hot wall surfaces and can evaporate easily. The evaporation rate is regulated by the heating bath temperature, the size of flask, the pressure of distillation and the speed of rotation. Advantages of the rotary evaporator (compared with static apparatus): With a vacuum rotary evaporator you can carry out single-stage distillation runs quickly and gently. Rotary evaporators are mainly used for: 1. Distillation of solvent 2. Concentration of solutions and suspensions 3. Crystallization or recrystallization 4. Synthesis and purifying of fine chemicals 5. Soxhlet extraction 6. Powder and granules drying 7. Recycling of solvent Based on the successful experience, HNZXIB Instruments supply 2L, 3L, 5L, 10L, 20L, 50L rotary evaporators. Advantages - 5 - 1. Adopting PTFE and fluorine rubber composite sealing, can maintain high vacuum degree. Gas-liquid separator, no reflux. 2. Host and vice highly effective double condenser, easy to install, good sealing, collection rate over 95%. 3. Continuous feeding is available. 4. There is a discharge valve, fast to collect solvent. 5. Vacuum gauge for operator to adjust appropriate vacuum degree. 6. Heating bath digital constant temperature control. Heating bath manual lift. 7. Reasonable structure, exquisite material: Mechanical parts are made of stainless steel and aluminum die casting. Glass parts are made of corrosion resistance, high temperature resistance, borosilicate glass. Rubber parts adopt new standard materials, easy to change for users. Technical Data - 6 - Model RE-1002 RE-2002 RE-5002 Evaporating flask (L) 10 20 50 Receiving flask (L) 5 10 20 Motor power (W) 180 180 180 Rotating speed (R/min) 0-120 0-120 0-90 Evaporation rate (L/H2O) >3L/h >5L/h >9L/h Condenser cooling surface 0.57 1 1.5 (sq.m.) Vacuum degree <133pa (1.33mbar, 1Torr, 0.098Mpa) Sealing mode PTFE sealing system Heating bath configuration Heating bath manual lifting Heating bath power (KW) 3 4.5 7 Temperature control range 0-99 for water/0-250 for oil (℃) Temperature fluctuation (℃) ±1 Condenser Vertical double condenser Voltage 220V/50HZ 220V/50HZ 380V/50HZ Installation RE-5002 rotary evaporator is composed of three parts: the mechanical parts, the glass parts and the heating bath. Installation steps - 7 - are as follow: 1. Screw vacuum gauge rod to the stainless steel rack hand-tight. 2. Remove one screw nut of the rack. Screw the rack to the base plate then tighten the nut on and make sure the vacuum gauge facing to the setter. 3. Base unit is placed on a stable surface near water. If uneven, operator can adjust four rubber feet. 4. Tighten digital converter on the rack, then connect motor five core plug. 5. Slide main condenser clamp over stainless steel rack. Tighten knurled screw of clamp carefully. 6. Mount the vapor tube on the motor and use the PTFE-seal to tighten. 7. Connect the vice condenser with the vapor tube and sustain it with bracket. Using the PTFE-seal to tighten. 8. Connect the receiving flask with the vice condenser and sustain it with bracket. Mount the vacuum switching valve on the junction. 9. Insert the main condenser into the vice condenser and tighten the clamp. 10. Mount the inlet valve, outlet valve and discharge valve. 11. Insert the locking pin of the motor and mount the evaporating flask on the motor. Remove the locking pin after tightening the clamp. 12. Move the heating bath under the evaporating flask. Add water to 2/3 pot. Adjust the height of heating bath. 13. Using the vacuum pipe to connect the exhausting port to the joint - 8 - above vacuum gauge. Connect another joint to the circulating water pump. 14. Mount the feeding tube and connect the device to the cooling water. Notes (1) Glassware should be cleaned before installation. (2) The standard port and the sealing surface should be coated with a little vacuum grease to increase air tightness. (3) Be sure that every parts are locked tightly before starting up . (4) Be sure to remove the locking pin before starting up. (5) Not to move the whole device. Operation The evaporation rate of the device depends on the following three points: 1. The higher vacuum degree, the faster the device evaporates. The vacuum degree should be not less than 0.096 Mpa. - 9 - 2. The higher the heating bath temperature, the faster the speed. Generally not more than 80 ° C. Specific temperature according to the process requirements. 3. The lower the cooling water temperature, the faster the speed. Using coolant is much better. I. Operation procedure 1. Vacuum: Do the following things if not reach the required vacuum degree after starting up the vacuum pump. Check the PTFE seal, tension ring, couplings to see whether they are sealed good. Check the vacuum pump to see how it works. The external vacuum tube connected to vacuum switch can adjust slightly to reach the best recovery rate and evaporation speed. 2. Feeding: Due to vacuum negative pressure, liquid material flow into the evaporating flask automatically through a hose. Do not feed more than half of its capacity. The device can achieve a continuous feed. When start feeding, operator should pay attention to: (1) Turn off the vacuum pump. - 10 - (2) Stop heating. (3) Open the feeding valve slowly when the device finish evaporating in case of back-flow. 3. Heating: The heating bath is equipped with advanced intelligent control panel. It is based on a computer chip as the main control unit. Using multiple digital filter circuit, interference automatic recovery, PID control and self-tuning function. It has advantages such as: high accuracy, stable and accurate temperature control, anti-interference ability, simple operation, etc. Evaporating flask is immersed by moving up and down via the heating bath lift. You can fill the heating bath with various heating bath fluids: * Tap water (no deionized or distilled water) * Oil with low viscosity (40 cP) and flashpoint > 260°C. Control panel - 11 - Sign Introduction Sign Introduction Set SV Setting temperature SET R/S < Shift key OUT1 Output1 ∨ Reduce the OUT2 Output2 temperature ∧ Raising the ALM Alarm temperature PV Actual temperature AT Auto-turning Using the auto-tuning function if the temperature error is large. The system will automatically calculate more suitable PID data for the - 12 - process and make temperature control more accurate and more stable. Press “ < ” or “ ∨ ” key for about 5 seconds, then release. “AT” lights up, “SV” flashing, and the device turns to auto-tuning condition. When finished, “AT” lights off. (When starting auto-tuning, the device must be in the heating state and the PV must be lower than the SV. If the device shuts down during auto-tuning, the process will be invalid.) Cut off the power when finish using the device. 4. Rotation: Turn on the switch of the digital converter and adjust the rotary button to achieve the most suitable speed. Pay Attention to avoid temperature fluctuations of heating bath. 5. Connected to the cooling water. 6. Solvent recovery: Open the outlet valve and let gas in. Open the discharge valve so that operator can collect the solvent. II. Considerations 1. About the vacuum degree - 13 - Vacuum degree is the most important technical data of rotary evaporator. However, operators often meet the problems with vacuum degree. That is often related to the nature of the medium solvent. Regularly people use water, ethanol, acetone, acetic acid, ethyl ether, petroleum ether, chloroform, and toluene as solvent in pharmaceutical and biochemical industries. General vacuum pump can not be resistant to strong organic solvent so you can choose special strong corrosion-resistant vacuum pumps. (Recommended the water
Recommended publications
  • European Patent Office of Opposition to That Patent, in Accordance with the Implementing Regulations
    (19) TZZ _T (11) EP 2 686 288 B1 (12) EUROPEAN PATENT SPECIFICATION (45) Date of publication and mention (51) Int Cl.: of the grant of the patent: C07C 217/56 (2006.01) C07C 217/62 (2006.01) 25.03.2015 Bulletin 2015/13 C07C 227/36 (2006.01) C07C 57/15 (2006.01) C07C 213/08 (2006.01) C07C 219/28 (2006.01) (2006.01) (21) Application number: 11796817.2 C07B 57/00 (22) Date of filing: 11.11.2011 (86) International application number: PCT/IB2011/055039 (87) International publication number: WO 2012/137047 (11.10.2012 Gazette 2012/41) (54) A PROCESS FOR PREPARING FESOTERODINE PROZESS ZUR HERSTELLUNG VON FESOTERODIN PROCÉDÉ DE PRÉPARATION DE FÉSOTÉRODINE (84) Designated Contracting States: • PATIL, Chetan AL AT BE BG CH CY CZ DE DK EE ES FI FR GB Gujarat GR HR HU IE IS IT LI LT LU LV MC MK MT NL NO Vadodara 390003 (IN) PL PT RO RS SE SI SK SM TR • PATEL, Ronak Gujarat (30) Priority: 07.04.2011 IN MM11722011 Vadodara 390003 (IN) • RAVAL, Prashant (43) Date of publication of application: Gujarat 22.01.2014 Bulletin 2014/04 Vadodara 390003 (IN) • PAREKH, Viral (73) Proprietor: Alembic Pharmaceuticals Limited Gujarat Vadodara 390003 (IN) Vadodara 390003 (IN) • SHAH, Hiral (72) Inventors: Gujarat • RAMAN, Jayaraman, Venkat Vadodara 390003 (IN) Gujarat Vadodara 390003 (IN) (74) Representative: Watson, Robert James et al • PATEL, Samir Mewburn Ellis LLP Gujarat 33 Gutter Lane Vadodara 390003 (IN) London EC2V 8AS (GB) • THAKOR, Indrajit Gujarat (56) References cited: Vadodara 390003 (IN) EP-A1- 2 281 801 WO-A2-2009/126844 • LADANI, Mahesh Gujarat Vadodara 390003 (IN) Note: Within nine months of the publication of the mention of the grant of the European patent in the European Patent Bulletin, any person may give notice to the European Patent Office of opposition to that patent, in accordance with the Implementing Regulations.
    [Show full text]
  • UCLA Electronic Theses and Dissertations
    UCLA UCLA Electronic Theses and Dissertations Title Novel microfluidic technologies for the concentration of radionuclides and radiotracers for positron emission tomography Permalink https://escholarship.org/uc/item/7qb3p6x1 Author Chao, Philip Hong-Sean Publication Date 2019 Peer reviewed|Thesis/dissertation eScholarship.org Powered by the California Digital Library University of California UNIVERSITY OF CALIFORNIA Los Angeles Novel microfluidic technologies for the concentration of radionuclides and radiotracers for positron emission tomography A dissertation submitted in partial satisfaction of the requirements for the degree Doctor of Philosophy in Bioengineering by Philip Hong-Sean Chao 2019 © Copyright by Philp Hong-Sean Chao 2019 ABSTRACT OF THE DISSERTATION Novel microfluidic technologies for the concentration of radionuclides and radiotracers for positron emission tomography by Philip Hong-Sean Chao Doctor of Philosophy in Bioengineering University of California, Los Angeles, 2019 Professor Pei-Yu Chiou, Co-Chair Professor Robert Michael van Dam, Co-Chair Positon emission tomography (PET) is an imaging modality capable of visualizing biomolecules in vivo and can be used to aid in disease diagnosis, staging of disease severity, and monitoring of disease response to treatment. PET relies on the use of tracers (i.e. biomolecules labeled with radionuclides) for imaging. Due to the short half-life of the radionuclides used, PET tracer production is typically performed right before an imaging event. Production of a PET tracer can be broken down into three major parts: production of the radionuclide, radiochemical synthesis of the tracer, and, lastly, purification, formulation and quality control testing of the tracer. Several groups, including our own, have looked into leveraging the benefits of microfluidics (reduced system size, finer control of reaction parameters, reduced reagent consumption) towards the production of PET tracers.
    [Show full text]
  • Tailoring Diesel Bioblendstock from Integrated Catalytic Upgrading of Carboxylic Acids: a “Fuel Property First” Approach Xiangchen Huoa,B, Nabila A
    Electronic Supplementary Material (ESI) for Green Chemistry. This journal is © The Royal Society of Chemistry 2019 Tailoring Diesel Bioblendstock from Integrated Catalytic Upgrading of Carboxylic Acids: A “Fuel Property First” Approach Xiangchen Huoa,b, Nabila A. Huqa, Jim Stunkela, Nicholas S. Clevelanda, Anne K. Staracea, Amy E. Settlea,b, Allyson M. Yorka,b, Robert S. Nelsona, David G. Brandnera, Lisa Foutsa, Peter C. St. Johna, Earl D. Christensena, Jon Lueckea, J. Hunter Mackc, Charles S. McEnallyd, Patrick A. Cherryd, Lisa D. Pfefferled, Timothy J. Strathmannb, Davinia Salvachúaa, Seonah Kima, Robert L. McCormicka, Gregg T. Beckhama, Derek R. Vardona* aNational Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, CO, United States bColorado School of Mines, 1500 Illinois St., Golden, CO, United States cUniversity of Massachusetts Lowell, 220 Pawtucket St., Lowell, MA, United States dYale University, 9 Hillhouse Avenue, New Haven, CT, United States *[email protected] Section S1: Experimental Methods Catalyst synthesis and characterization Pt/Al2O3 catalyst was prepared by strong electrostatic adsorption method with chloroplatinic acid hexahydrate as Pt precursor. Al2O3 of 30-50 mesh and Pt precursor were added to deionized water, and solution pH was adjusted to 3 by adding HCl. After stirring overnight, the catalyst particles were recovered by filtration extensively washed with -1 deionized water. The catalyst was dried in the air and reduced in flowing H2 (200 mL min ) at 300°C for 4 h. BET surface area was determined by nitrogen physisorption using a Quadrasorb SI™ surface area analyzer from Quantachrome Instruments. Samples of ~80–120 mg were measured using a 55-point nitrogen adsorption/desorption curve at -196°C.
    [Show full text]
  • Rotary Evaporator (Single/Dual Condenser Type)
    Version : 2020 Rotary Evaporator (Single/Dual Condenser Type) USA-RE20-UL/USA-RE20D-UL USA-RE50-UL/USA-RE50D-UL Introduction Rotary evaporator produced by USA LAB Inc. is a new type of product developed by the company for many years of design and production experience. The laboratory instrument rotary evaporator is mainly used to continuously distill a large amount of volatile solvents under reduced pressure. In particular, the concentration of the extract and the distillation of the receiving liquid at the time of chromatographic separation can be used to purify the reaction product. The basic principle of a rotary evaporator is vacuum distillation, that is, under reduced pressure, the distillation flask is continuously rotated as the solvent is distilled. The company's after-sales service will accompany you from the date of purchase. Please refer to this instruction manual (operation manual) before using. If you have any questions, please feel free to contact us and we will do our best to serve you. TABLE OF CONTENTS 1. Working principle and scope of application 4 2. Precautions 4 3. Structure and composition 7 3.1 Outside view 7 3.2 Operating Instructions for operating panel (Figure 6) 12 3.3 Operation instructions 13 3.4 Operation of over-temperature protector 14 4. Installation 15 4.1 Stripping 15 4.2 Installation diagram of upright rod 15 4.3 Installation diagram of three-way flask, rotating shaft, 16 evaporating flask 4.4 Installation diagram of main condenser, receiving 17 flask and check valve Other parts installation 19 5. Specification 20 6.
    [Show full text]
  • Evaporator Ebook 2017
    1 Lab Manager’s Product Resource Guide: Evaporators Rotary Evaporators: Must Have Features 2 Angelo DePalma PhD Choosing the Best Evaporator For Your Application (Video) 4 Lab Manager Tips for Choosing an Evaporator for Your Lab 5 Ryan Ackerman Reducing, Distilling, Recycling and Concentration 7 Angelo DePalma PhD Selecting a Vacuum Pump for Rotary Evaporation (Video) 8 Lab Manager All-in-One Versions and Other Options to Enhance Efficiency 10 Mike May PhD Nitrogen Evaporators: Making Concentration Easier & Greener 12 Mike May PhD Evaporator Product Finder 15 Lab Manager Manufacturer List 15 2 Rotary Evaporators: Must-Have Features Rotary evaporators, or “rotovaps,” may be found wherever processes require sample concentration or solvent distillation. By Angelo DePalma PhD Rotary evaporators are standard laboratory equipment found in nearly all laboratories. Chemical, pharmaceutical, food, and environmental industries are the most common users, but rotary evaporators, or “rotovaps,” may be found wherever processes require sample concentration or solvent distillation. All rotary evaporators include a heating bath, condenser, collecting vessel, and rotating sample or distillation flask. BUCHI Corporation (New Castle, DE), a leading manufacturer of rotovaps, still sells a large number of those simple units to academic and even industrial labs. But another world of rotary evaporation exists for laboratories that value application versatility, automation, and connectivity. “Our largest-volume market has been and remains pharmaceuticals, and they’re willing to pay for a high degree of automation, for many features that go beyond simple rotovaps,” says Jason Wagner, VP of marketing at BUCHI. “But there’s still a big market for stripped-down, no-frills models.” 3 A “full system” has a chiller to replace the use of cold tap water in the condenser unless dry ice is readily available.
    [Show full text]
  • Rotary Evaporators | Distillation Made Easy!
    Rotary Evaporators | Distillation made easy! The IKA® RV 10 rotary evaporator’s award winning design and performance have made a significant difference in your laboratory. IKA® is pleased to introduce the RV 8 rotary evaporator. The RV 8, a functional basic model with manual lift and adjustable immersion angle is the most economical option in our range. For fully automated distillation, IKA® has developed a new RV 10 control with direct connection to a speed controlled vacuum pump and automatic boiling point detection. The IKA® range of RV 8, RV 10 basic, digital and control rotary evaporators offers excellent distilling solutions to the demanding user. Value for money, design and technology - all for your convenience! Our advanced RV 10 rotary evaporators stand out because of their extraordinary features, which include the following: a digital temperature display, interval operation, soft start and an adjustable end position recognition to protect the glass- ware from breaking. The digital version offers an RS 232 in- terface and the control version an RS 232 / USB interface for connection to labworldsoft® and for online firmware updates. NEW RV 8 Year 5 warranty* * 2+3 years after registering at www.ika.com/register, glassware and wearing parts excluded Drive: Protection class according to DIN EN 60529: IP 20 Heating bath: Protection class according to DIN EN 60529: IP 21 2 3 RV 8 | Smart choice! RV 8 | One-hand lifting mechanism The IKA® rotary evaporator line has a new family member - the RV 8. The new entry level RV 8 rotary evaporator comes equipped with an easy to use manual lift with integrated safety ”lift out function“ and is ideal for all standard evaporating applications.
    [Show full text]
  • Rotary Evaporators
    R o t a r y Evaporators Rotary evaporators are commonly used for separating solvents, the Stuart® range offers simple control & a variety of glassware configurations, vertical, diagonal & cold finger condensing depending on your requirements. All configurations are available with plastic coated glass. R o t a r y Evaporators • Digital control Each unit is also provided with an easy to use • Can be orientated for left or right handedness vacuum release and a continuous feed system, • Simple, counterbalanced lift mechanism which allows more solvent to be drawn into the • PTFE/glass liquid pathway for chemical inertness rotating Florentine flask without the need to stop • Long life graphite impregnated PTFE vacuum seal the operation. • Efficient flask and vapour tube ejection system There are three orientations of condenser available A Rotary evaporator is a distillation unit that depending on the application and space available: incorporates an efficient condenser with a rotating sample flask. As the flask containing the solvent is • The RE400 rotary evaporator comes with a rotated, it continually transfers a thin layer of liquid diagonally orientated glass condenser for over the entire inner surface. This gives a very large standard distillations. surface area for evaporation, the sample or Florentine • The RE401 rotary evaporator comes with a vertically flask can additionally be heated by an accessory bath orientated glass condenser for distillation of to accelerate the process. The entire system has been solvents with higher boiling points. 20% narrower designed to be vacuum tight, an accessory vacuum than RE400 saving space. pump can be connected to reduce the overall pressure • The RE402 rotary evaporator comes with a and hence the boiling point of your sample.
    [Show full text]
  • Rotary Evaporator Fact Sheet
    Rotary Evaporator Fact Sheet What are Rotary Evaporators? A rotary evaporator (also called as “rotavap” or “rotovap”) is a device used in labs for the efficient and gentle removal of solvents from samples by evaporation. The picture on the right shows what a typical rotary evaporator includes. What are Potential Hazards? • Burn hazard from heating water Source: bath (usually range from 25 – http://www.chem.ucalgary.ca/courses/351/laboratory/rotavap.pdf 95 °C) or cryogens used for cooling. • Implosion hazard from vacuum system. • Ignition hazard if flammable liquid vapors escape the apparatus or accumulate in the pump. • Inhalation hazard if toxic chemical vapors escape the apparatus. • Pinch point hazard from the motor unit and manual quick-action jack. • Entanglement with spinning parts. • Electrocution/shock hazard from the outlet. • Cut hazard from broken flasks. How to Work Safely with Rotary Evaporators? 1. Wear lab coats, eye protection (safety glasses or goggles), closed-toes shoes, and appropriate gloves while operating the equipment. 2. Tie back long hair and do not wear loose items to avoid entanglement. 3. Ensure that the apparatus is maintained in a good working order. Seals should be checked periodically and replaced as necessary. Decrease in vacuum and leaking are generally indications that seals should be replaced. 4. Use a vacuum source that is appropriate for the level of vacuum needed. Diaphragm pumps are appropriate for most applications. Belt pumps and rotary vane pumps provide high levels of vacuum that can cause excessive bumping (i.e., flash boiling of solvent) and clog traps. Water aspirators should not be used as these can allow solvent vapors to enter drains and waste large volumes of water.
    [Show full text]
  • RV 10 Rotary Evaporator RV 10 Rotary Evaporator Overview of Components 04 RV 10 Basic and RV 10 Digital 05 RV 10 Control 06 Technical Data 07
    RV 10 Rotary Evaporator RV 10 Rotary Evaporator Overview of components 04 RV 10 basic and RV 10 digital 05 RV 10 control 06 Technical data 07 RV 10 Accessories Overview of featured glass accessories 08 Set of glassware, protective cover 09 Condensers 10 Vapor tube, evaporation flasks, additional accessories 11 Additional accessories, receiving flasks 12 Miscellaneous accessories 13 RV 10 System accessories Magnetic valves, choke valve 14 Filter, pressure regulating valve, chillers 15 Supplementary vacuum system 16 Software labworldsoft® 17 03 You can change states of aggregation. Or the way you work with them. With the new RV 10 range of rotary evaporators, IKA® has confirmed that there is always room for improvement, even when it comes to one of the oldest of chemical processes: distillation. The RV 10 Rotary Evaporators set new standards for safety, efficiency and ease of use. Great attention is paid to the issue of safety, from the Basic version upwards. Every model features a lifting mechanism that raises the evaporator piston out of the heating bath in case of power failure. The comprehensive safety features also include interval operation, smooth start, end position recognition for the evaporator piston, and a timer function. The Digital version also provides a digital temperature display and an RS 232 interface. For fully automated distillation, IKA® offers the Control version complete with integrated vacuum controller, USB interface and graphical display. Years 10 Lifetime warranty* – No spare part costs during lifetime – No repair
    [Show full text]
  • Analysis for Pesticides
    LAG - Genevac Article 18/9/06 4:39 pm Page 1 Laboratory Products Focus IMPROVING ANALYSIS OF PESTICIDES A NEW METHOD DEVELOPMENT PROTOCOL TO INCREASE RECOVERY OF VOLATILE COMPOUNDS Anna Maria Marsico, Environmental Protection Agency of Tuscany (ARPAT) Determination of pesticide contamination EXPERIMENTAL SAMPLE CONCENTRATION of fruit and vegetables usually follows Analytical method development involves the METHOD several steps, including, extraction of careful evaluation of instruments with regard to analytes from the sample, concentrating The evaporation method may be set to run for a issues such as ease of use, efficiency, and most fixed time in order to stop the system when we the extract, post extraction clean-up, importantly analyte recovery and integrity. In estimate that we have reached a certain residual solvent exchange, and finally, this study the performance of a new centrifugal volume in each tube. This method was found to be determination of the analytes present. evaporator manufactured by Genevac, U.K., unreliable, therefore a “solvent keeping” approach is evaluated. During sample preparation, evaporation was trialed where a 1ml aliquot of toluene was added to each sample. Toluene (boiling point becomes a critical step when the pesticides The stages of the research methodology 110°C) is less volatile than ethyl acetate (boiling are semi-volatile compounds, because are as follows: point 77°C) in which the samples were dissolved. some of the compound may be lost during • Determination of which analytes are suitable for the study, in terms of volatility and The object of the study was to verify if pesticides the concentration and evaporation stages.
    [Show full text]
  • Distillation with a Rotary Evaporator 1
    BÜCHI Training papers Distillation with a Rotary Evaporator 1 Training Papers Distillation with a Rotary Evaporator Contents 1 Introduction 2 What is a rotary evaporator? 3 Selecting the right rotary evaporator 3.1 Rotavapor® models 3.2.1 Heating bath 3.2.2 Heat transfer medium 3.3.1 Glass assemblies 3.3.2 Rotary evaporator RE or EL? 3.4 Special accessories 4 Working with the rotary evaporator 4.1 Heating/cooling 4.2 Pressure control 4.3 Evaporating flask and rotation 5 The thermal pump 6 How to distill? 7 Definitions Progress built on tradition Copyright© Rosemary Hoegger; BÜCHI Labortechnik AG 1998 English, Version B (16 pages) Order No. Distillation with a Rotary Evaporator 97743 BÜCHI Training papers Distillation with a Rotary Evaporator 2 1 Introduction From the beginnings of the ancient alchemists1 to today's modern research, the principles behind simple laboratory distillation apparatus have hardly changed. Basic construction of distillation apparatus separation part condensation part collection part evaporation part Evaporation part This is where the mixture is made to evaporate by heating. Separation/ This is where the actual separation of solvent and non-volatile or less fractional part volatile components takes place. Condensation/ Originally this section was only required when the distillate was to be cooling part reused. Today, condensation should be as complete as possible for environmental reasons. Collection part This is where the various condensates are collected. BÜCHI Training papers Distillation with a Rotary Evaporator 3 2 What is a rotary evaporator? A rotary evaporator is a specially designed instrument for the evapora- tion of solvent (single-stage or straight distillation) under vacuum.
    [Show full text]
  • Method 204F - Volatile Organic Compounds Content in Liquid Input Stream (Distillation Approach)
    While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the Government Printing Office's eCFR website: (http://www.ecfr.gov/cgi-bin/text-idx?c=ecfr&SID=515695243cf17599503c0e7a89f654a4&rgn=div9&view=text&node=40:2.0.1.1.2.23.11.5.30&idno=40) Method 204F - Volatile Organic Compounds Content in Liquid Input Stream (Distillation Approach) 1. Introduction 1.1 Applicability. This procedure is applicable for determining the input of volatile organic compounds (VOC). It is intended to be used as a segment in the development of liquid/gas protocols for determining VOC capture efficiency (CE) for surface coating and printing operations. 1.2 Principle. The amount of VOC introduced to the process (L) is the sum of the products of the weight (W) of each VOC containing liquid (ink, paint, solvent, etc.) used, and its VOC content (V), corrected for a response factor (RF). 1.3 Sampling Requirements. A CE test shall consist of at least three sampling runs. Each run shall cover at least one complete production cycle, but shall be at least 3 hours long. The sampling time for each run need not exceed 8 hours, even if the production cycle has not been completed. Alternative sampling times may be used with the approval of the Administrator. 2. Summary of Method A sample of each coating used is distilled to separate the VOC fraction. The distillate is used to prepare a known standard for analysis by a flame ionization analyzer (FIA), calibrated against propane, to determine its RF.
    [Show full text]