Introduction Suppliers to Brand Name Distributors and Vehicle Manufacturers

Total Page:16

File Type:pdf, Size:1020Kb

Introduction Suppliers to Brand Name Distributors and Vehicle Manufacturers tel: +44 (0) 1254 300 730 fax: +44 (0) 1254 237 432 e-mail: [email protected] INTRODUCTION SUPPLIERS TO BRAND NAME DISTRIBUTORS AND VEHICLE MANUFACTURERS COMPANY PROFILE Since its formation in 1997 CurrentCare Ltd has established a market supplying and supporting brand name distribution companies throughout Europe, as well as main stream & specialist vehicle manufacturers and ‘First Tier’ OEM’s & OES’s. As well as supplying to private brand distributors, we have also launched a range of branded product ranges, each uniquely branded with no reference to CCL. These offer distributors the option to stock products in high impact branded packaging, supported by marketing and promotional material and technical information. Each brand also has it’s own online eco- catalogue for use by you and your customers, where you will always find the most up-to-date product range information, vehicle application data, cross reference data and technical support. As with the branded product packaging, the eco- catalogues contain no reference to CCL. Although CCL already has a large product range, we realise that we must continue to increase the range and service that we offer, in addition to rapidly responding to our customers changing requirements and so are eager to discuss the development of new/bespoke products at the request of our customers and as part of our continuous improvement strategies we would warmly welcome your suggestions as to how we can improve the service that we currently offer. To that end we are always mindful of our greatest asset, which is the opportunities that YOU, our valued customer offer us. Our greatest strengths are found within the high level of customer support, product knowledge and quality that every member of the CCL team prides itself on, along with our high level of flexibility. For the most up to date product, vehicle application & technical information, please visit the relevant website or technical portal: currentcare.co.uk sensors.uk.com bladesdirect.co.uk evolutionblades.com iguanablades.com theonlyclips.co.uk DISCLAIMER Whilst every care has been taken to ensure that this catalogue is accurate CCL or your distributor cannot be held responsible for any inaccuracies with the information contained herein. Please note that product specifications and part numbers may change from time to time in line with our policy of continual improvement. CCL therefore reserves the right to alter product specifications without notice. Manufacturers part numbers and application details are used for reference purposes only. All sections of this catalogue are the © Copyright of CCL 1998-2014 All Rights Reserved. Errors and Omissions Excepted. 1 tel: +44 (0) 1254 300 730 fax: +44 (0) 1254 237 432 e-mail: [email protected] 2 INDEX LISTING BY PRODUCT GROUP PRODUCT DESCRIPTION PAGE # PRODUCT DESCRIPTION PAGE # ABS SENSORS 101 IGUANA BLADES 107 ALUMINIUM NON-RETURN VALVES 85 & 120 INDEX BY PART NUMBER 5 TO 6 AUDIBLE WARNING DEVICES 73 TO 79 LAMBDA SENSORS 101 BALLAST RESISTOR 53 LED FLASHER UNITS 29 TO 30 BATTERY ISOLATOR SWITCHES 82 MAF SENSORS 101 BATTERY SENSITIVE RELAYS 12 TO 13 MAP SENSORS 101 BATTERY TERMINALS 82 MAXI RELAYS 10 TO 12 BATTERY TERMINAL REMOVAL TOOL 83 MICRO RELAYS 14 TO 15 BLADES 104 TO 105 MINI CLIPS 102 TO 103 BUZZERS 73 MINI RELAYS 7 TO 13 CAM SENSORS 101 NON-RETURN VALVES (PLASTIC) 120 CIGARETTE LIGHTER 83 NON-RETURN VALVES (ALUMINIUM) 85 & 120 CLIPS 102 TO 103 P-CLIPS 102 TO 103 COMPANY PROFILE 1 PETROL PIPE CLIPS 102 TO 103 CROSS REFERENCE SECTION 137 TO 165 PREMIUM CLIPS 102 TO 103 CSS SENSORS 101 PRIMER PUMP APPLICATION GUIDE 87 DIESEL FUEL FILTERS 85 PRIMER PUMPS 86 TO 87 DIESEL PRIMER PUMP APPLICATION GUIDE 86 RADIATOR FANS 98 TO 99 DIESEL PRIMER PUMPS 86 TO 87 RELAY BASES & RELAY BASE KITS 24 DIESEL STOP SOLENOID APPLICATION GUIDE 88 TO 96 RELAY TERMINAL GUIDE 23 DIESEL STOP SOLENOIDS 88 RELAYS 7 TO 23 DISCLAIMER 1 & 166 REVERSING ALARMS 73 EVOLUTION BLADES 106 SENSORS 101 EXACT FIT HORNS 76 TO 79 SOLENOIDS 88 FANS 98 TO 99 STEEL TOW ROPE 83 FLASHER UNIT APPLICATION GUIDE 31 TO 36 STOP SOLENOID APPLICATION GUIDE 89 TO 96 FLASHER UNIT BUYERS GUIDE 25 TO 30 STOP SOLENOID BUYERS GUIDE 88 FLASHER UNIT TERMINAL GUIDE 30 STOP SOLENOIDS 88 TO 96 FLASHER UNITS 25 TO 36 SUREFLEX CLIPS 102 TO 103 FUEL FILTERS 85 SWITCHES 82 FUEL INJECTION RELAY APPLICATION GUIDE 22 TO 23 THERMOSWITCH 99 FUEL INJECTION RELAY BUYERS GUIDE 21 TOW ROPE 83 FUEL INJECTION RELAYS 21 TO 23 TPS SENSORS 101 GLOW PLUG RELAY APPLICATION GUIDE 17 TO 20 TUBE CONNECTORS 120 GLOW PLUG RELAY BUYERS GUIDE 16 UNIVERSAL RADIATOR THERMOSTAT 99 GLOW PLUG RELAYS 16 TO 20 VOLTAGE SENSITIVE RELAYS 12 TO 13 HEADLAMP CONTROL RELAYS 12 WASHER ACCESSORIES 119 TO 120 HORN APPLICATION GUIDE 79 WASHER BOTTLE CAPS 120 HORNS 74 TO 79 WASHER BOTTLES 111, 115 & 116 HOSE CLIPS 102 TO 103 WASHER JETS 119 HYDRAULIC WASHER JETS 115 WASHER PUMP APPLICATION GUIDE 121 TO 136 IGNITION COIL APPLICATION GUIDE 54 TO 71 WASHER PUMP BUYERS GUIDE 109 TO 118 IGNITION COIL BUYERS GUIDE 53 WASHER PUMP GROMMETS 119 IGNITION COILS 53 TO 71 WASHER PUMPS 108 TO 136 IGNITION MODULE APPLICATION GUIDE 41 TO 52 WASHER SYSTEM COMPONENTS 119 TO 120 IGNITION MODULES BUYERS GUIDE 37 TO 40 WASHER TUBE CONNECTORS 120 IGNITION MODULES 37 TO 52 WIPER ARM REMOVAL TOOL 83 IGNITION SWITCH 82 WIPER BLADES 104 TO 107 3 tel: +44 (0) 1254 300 730 fax: +44 (0) 1254 237 432 e-mail: [email protected] 4 tel: +44 (0) 1254 300 730 INDEX fax: +44 (0) 1254 237 432 e-mail: [email protected] BY CCL PART NUMBER CCL REF PAGE # CCL REF PAGE # CCL REF PAGE # CCL REF PAGE # CCL REF PAGE # 01-001 25 02-014 8 03-007 109 03-068 116 04-044 38 01-001H 25 02-015 8 03-008 109 03-069 116 04-045 39 01-002 25 02-015B 8 03-009 109 03-070 116 04-046 39 01-002H 25 02-016 8 03-010 110 03-071 116 04-047 39 01-003 25 02-016B 8 03-011 110 03-072 116 04-048 39 01-004 25 02-017 8 03-012 110 03-073 116 04-050 39 01-004H 25 02-017B 8 03-013 110 03-074 116 04-051 39 01-005 25 02-018 9 03-014 110 03-075 116 04-052 39 01-006 25 02-018B 9 03-015 110 03-076 117 04-053 39 01-007 26 02-019 9 03-016 110 03-077 117 04-054 39 01-008H 26 02-019B 9 03-017 110 03-078 117 04-055 39 01-009 26 02-020 9 03-018 110 03-079 117 04-057 39 01-010 26 02-020B 9 03-019 111 03-080 117 04-059 39 01-011 26 02-021 9 03-020 111 03-081 117 04-060 39 01-012 26 02-021B 9 03-021 111 03-082 117 04-061 39 01-013 26 02-022 9 03-022 111 03-083 117 04-062 39 01-014 26 02-022B 10 03-023 111 03-084 117 04-063 39 01-016 26 02-024 10 03-024 111 03-085 118 04-064 39 01-017 27 02-024B 10 03-025 111 03-086 118 04-065 39 01-018H 27 02-025 10 03-026 111 04-001 37 04-066 39 01-019 27 02-026 10 03-027 111 04-002 37 04-067 39 01-020 27 02-027 10 03-029 112 04-003 37 04-068 40 01-022 27 02-028 10 03-030 112 04-004 37 04-069 40 01-024 27 02-029 10 03-031 112 04-005 37 04-070 40 01-025 27 02-030 10 03-032 112 04-006 37 05-003 73 01-026 27 02-031 11 03-033 112 04-007 37 05-004 73 01-027 27 02-032 11 03-034 112 04-008 37 05-005 73 01-028 28 02-033 11 03-035 112 04-009 37 05-007A 73 01-033 28 02-034 11 03-036 112 04-010 37 05-008A 73 01-034 28 02-035 11 03-037 112 04-011 37 05-010 73 01-035 28 02-036 11 03-038 113 04-012 37 05-011 73 01-037 28 02-037 11 03-039 113 04-013 37 05-012 73 01-038 28 02-038 11 03-040 113 04-015 37 05-024 73 01-039 28 02-039 11 03-041 113 04-016 37 06-002 74 01-040 28 02-040 12 03-042 113 04-017 37 06-003 74 01-041 28 02-041 12 03-043 113 04-018 37 06-004 75 01-042 29 02-042 12 03-044 113 04-019 37 06-005 75 01-043 29 02-045 12 03-045 113 04-020 37 06-007 76 01-044 29 02-046 12 03-046 113 04-021 37 06-008 75 01-045 29 02-047 12 03-047 114 04-022 38 06-009 75 01-046 29 02-048 12 03-048 114 04-023 38 06-010 76 01-047 29 02-049 12 03-049 114 04-024 38 06-011 76 01-048 29 02-050 12 03-050 114 04-025 38 06-012 76 01-049 29 02-052 13 03-051 114 04-026 38 06-013 76 01-050 29 02-053 13 03-052 114 04-027 38 06-014 77 01-052 30 02-054 13 03-053 114 04-028 38 06-015 77 01-053 30 02-055 13 03-054 114 04-030 38 06-016 77 02-001 7 02-056 13 03-055 114 04-031 38 06-017 77 02-002 7 02-057 13 03-056 115 04-032 38 06-018 77 02-003 7 02-058 13 03-057 115 04-033 38 06-019 77 02-004 7 02-059 13 03-058 115 04-034 38 06-020 77 02-007 7 02-060 13 03-059 115 04-035 38 06-021 77 02-008 7 03-001 109 03-060 115 04-036 38 06-022 77 02-009 7 03-002 109 03-061 115 04-038 38 06-023 78 02-010 7 03-003 109 03-062 115 04-039 38 06-024 78 02-011 7 03-004 109 03-065 115 04-040 38 06-025 78 02-012 8 03-005 109 03-066 115 04-042 38 06-112H 75 02-013 8 03-006 109 03-067 116 04-043 38 06-112HD 74 5 INDEX tel: +44 (0) 1254 300 730 fax: +44 (0) 1254 237 432 BY PART CCL NUMBER e-mail: [email protected] CCL REF PAGE # CCL REF PAGE # CCL REF PAGE # CCL REF PAGE # CCL REF PAGE # 06-112L 75 08-074 85 15-004 82 FF-105 97 1X-SSS 102 06-112LD 74 08-075 85 15-005 82 FF-106 97 1X-SSS-B 102 06-212H 75 09-001 53 15-006 82 FF-112 97 20-MC 102 06-212H/E 76 09-002 53 15-007 82 FF-113 97 21-MC 102 06-212HD 74 09-003 53 15-008 82 RBA-001 83 22-PC 102 06-212L 75 09-004 53 15-009 82 000-MSE 102 23-001 102 06-212L/E 76 09-115 53 15-010 82 000-MSE-B 102 23-003-MSE 102 06-212LD 74 09-200 53 15-011 82 000-SSS 102 23-003-SSS 102 06-212LD/E 76 09-201 53 15-012 82 000-SSS-B 102 23-004 102 06-224H 74 09-202 53 19-002 82 00-MSE 102 23-MCAB 102 06-224HD 74 09-203 53 19-002K 82 00-MSE-B 102 25-PC 102 06-224L 75 09-204 53 19-003 82 00-SSS 102 28-PC 102 06-224LD 74 09-205 53 19-003K 82 00-SSS-B 102 2A-MSE 102 06-224LD/E 76 09-210 53 19-005 82 01-MSE 102 2A-MSE-B 102 08-001 53 09-220 53 19-005K 82 01-MSE-B
Recommended publications
  • Relay Terminal Designations According to DIN 72552
    Relay Terminal Designations according to DIN 72552 Terminal Designation Terminal Designation 15 Switch-controlled plus downstream from battery Current relay (from ignition switch) 84 Input: Actuator and relay contacts 15a In-line resistor terminal leading to coil and 84a Output: Actuators starter Switching relay 30 Line from battery positive terminal (direct) 85 Output: Actuator (negative winding end or Series/parallel battery switch 12/24V ground) 30a Line from battery positive terminal II 86 Input: Actuator 31 Return line from battery negative terminal or 86a Start of winding ground (direct) Start of winding or first winding coil 31b Return line to battery negative terminal or Relay contact for NC and changeovers contacts ground via switch or relay (switch-controlled 87 Input ground) 87a First output (NC-contact side) 31a Battery changeover relay 12/24 V 87b Second output Return line to Battery II negative pole 87c Third output 48 Terminal on starter and start-repeating relay for 87z First input monitoring starting process 87y Second input Flasher relay (pulse generator) Relay contact for NO contact 49 Input 88 Input 49a 49b Output Relay contact for NO contact and changeover Output to second flasher relay contacts (NO side) Starter 88a First output 50 Starter control (direct) 88b Second output Battery switching relay Relay contact for NO contact 50a Output for starter control 88z First input Starter control 88y Second input 50b Dual starters in parallel operation with sequen- Generator/alternator and voltage regulator tial control B+
    [Show full text]
  • Elektor Magazine
    0©® >r november 1980 - UK 03 selektor an r.p.m. indicator as an economy guide \Z contents A car engine is most efficient when the amount of energy it produces is closest to the amount consumed. This occurs at an engine speed that produces the maximum torque output. This circuit features both optical and acoustic indications to enable the driver to change gear at the opti- mum time in order to keep the engine speed within its most efficient range. draught detector However well insulated you think your house is, there are bound to be a few nooks and crannies which will allow interior heat to escape. With the aid of this electronic draught detector they will be found quite easily and the results may surprise you. how to recycle dry cell batteries energy saving know how The 'energy crisis' sounds as familiar to our ears as VAT - its something we have to cope with every day of our lives. It makes sense to save energy but a clear indication as to how and where it could be saved in the home is rarely given. This article takes a look at the central heating system, one of the largest domestic energy consumers. simple fuel economy meter A meter indicating fuel consumption on a digital display while the car is UK EDITORIAL STAFF moving would appear to be a popular project. With the aid of the modules T. Day E. Rogans described in this article it should be possible to use any transducer. automatic pump control 11-25 In most central heating systems the pump has to work continually both day and night.
    [Show full text]
  • 2-20 Praeclarum.Indd
    For Rolls-Royce and Bentley Enthusiasts PRÆCLARVM The National Journal of the Rolls-Royce Owners’ Club of Australia No. 2-20 April 2020 AX201 finds a New Owner Quidvis recte factvm quamvis hvmile præclarvm Whatever is rightly done, however humble, is noble. Royce, 1924 PRÆCLARVM The National Journal of the Rolls-Royce Owners’ Club of Australia No. 2-20 April 2020 Issue 307 Regular Items Features Events Calendar 7779 From the Editor 7780 From the Federal President 7781 News from the Registers 7802 Book Reviews 7807 Market Place 7809 Articles and Features From the Sir Henry Royce Foundation: Russell Rolls, Chairman of Trustees, 7782 SHRF, gives the details of the recent loan and refurbishment of a Rolls-Royce diesel 'Eagle' truck engine for display at to the SHRF's Coolum, Qld, Museum. Photo: Gil Fuqua (USA) Photo: Rolls-Royce’s most iconic car, AX201, fi nds an enthusiastic new owner: 7783 Præclarvm is pleased to advise that Sir Michael After a period of mistaken rumours, David Berthon (NSW) is able to let Kadoorie of Hong Kong is the mystery buyer of Præclarvm lead with the news that Sir Michael Kadoorie, of Hong Kong, is the Rolls-Royce AX201 "Silver Ghost". Read David excited to have purchased the iconic AX201, "Silver Ghost". Berthon's story of the sale on page 7783. Oscar Asche, the 1910 Silver Ghost, 1237, and Two Versions of Chu Chin 7786 Chow. Ian Irwin (ACT) has been searching the Country's various Archives to present a story that centres around early Rolls-Royce motoring history. 1975 Silver Shadow Saloon (SRH22160) Successfully Completes the 2019 7788 Peking to Paris Rally (Part 4): Brothers, Steve and Alan Maden (Vic) fulfi lled a long-term desire and completed the 2019 Rally.
    [Show full text]
  • Electrical System the Manual Also States
    Page 1 of 103 Page 2 of 103 Bad connections are a frequent cause of problems in classic cars, and high-resistance connections can be the most confusing to deal with, small increases in resistance Contents Index So you think you want an MGB or V8? having a disproportionate effect on the circuits affected. The Lucas Fault Diagnosis Body Brakes Clutch Cooling Electrics Engine Fuel Gearbox Heater Ignition Propshaft Rear axle Steering and Suspension Wheels and Tyres Service Manual states: Miscellaneous Downloadable PDFs The sectioned MGB at the British Motor Museum, Gaydon "The acceptable volt-drop figure for most circuits is 10% of system voltage (1-2v on a 12v system) but there are exceptions to this rule as in the case of the starter circuit where the maximum voltage drop is 0.5v." Electrical System The manual also states: "The majority of procedures involve circuit testing and the principle used will be If you find the information here useful, that of checking for 'voltage drop' where a voltmeter is connected in parallel with you may like to make a small contribution the particular circuit to be tested. Last updated 29-Nov-2019 to help offset the costs of providing it. Thank you. "As voltage drop exists only when current is flowing and varies according to the amount of current it is essential that the circuit is tested 'under load', i.e. whilst Automotive Electrics Basics - Part 1 - Terminology and Part 2 - Typical faults, symptoms, and passing its normal current. In certain cases this current will be measured using a diagnostic techniques test ammeter." Ammeters and Voltmeters Alternator/Dynamo Anti Run-on Valve Batteries and Chargers Battery Cut- That is exactly the principle that is followed in these pages.
    [Show full text]
  • Home Automation Using Arduino
    HOME AUTOMATION USING ARDUINO by Name Roll No. Registration No: ANIRBAN BHOWMIK 11700314015 141170110197 of 2014- 2015 SANDIP KUMAR DAS 11700314080 141170110262 of 2014- 2015 SOUVIK ACHARYA 11700314107 141170110289 of 2014- 2015 TUSHARKANTI 11700315146 151170120047 of 2015- MURMU 2016 A comprehensive project report has been submitted in partial fulfillment of the requirements for the degree of Bachelor of Technology in ELECTRONICS & COMMUNICATION ENGINEERING Under the supervision of Mrs.Pampa Debnath Professor Department of Electronics & Communication Engineering RCC INSTITUTE OF INFORMATION TECHNOLOGY Affiliated to Maulana Abul Kalam Azad University of Technology, WestBengal CANAL SOUTH ROAD, BELIAGHATA, KOLKATA – 700015 May,2018 1 CERTIFICATE OF APPROVAL This is to certify that the project titled HOME AUTOMATION SYSTEM USING ARDUINO carried out by Name Roll No. Registration No: ANIRBAN BHOWMIK 11700314015 141170110197 of 2014- 2015 SANDIP KUMAR DAS 11700314080 141170110262 of 2014-2015 SOUVIK ACHARYA 11700314107 141170110289 of 2014-2015 TUSHARKANTI MURMU 11700315146 151170120047 of 2015-2016 for the partial fulfillment of the requirements for B.Tech degree in Electronics and Communication Engineering from Maulana Abul Kalam Azad University of Technology, West Bengalis absolutely based on his own work under the supervision of Mrs. Pampa Debnath. The contents of this thesis, in full or in parts, have not been submitted to any other Institute or University for the award of any degree or diploma. Optional in case of External Supervisor
    [Show full text]
  • Longer Service Intervals Train Australian Motorists to Neglect Their Vehicles
    Issue 54 Tech Nov/Dec www.tat.net.au Spotlight 2016 • Vehicle servicing • Electrical Longer service intervals train Australian motorists to neglect their vehicles Join TaT today A$130 (NZ$165) gives you: 12 months membership to TaT 6 magazines mailed to your address Like us on Access to solutions Facebook ‘s a fact - problem solving page 23 online Technical assist service Visit: www.tat.net.au chnic e THE ia t n y INDEPENDENT s b NETWORK f • Merc • Magna • Camry • Jaguar o s r n t ia On the blink TCL sucks Resists fans Not so cranky echnic a year, but the network has grown far Also in this issue, there are stories about beyond the pages of the magazine. our expanded stable of writers, some UP FRONT new, some familiar, but all bringing a new In this issue, you will read stories about with Ken Newton global perspective to the everyday issue a new diagnostic program called Scan of fixing broken motor cars. Data, developed by Rod Maher at South hen Jeff Smit phoned me Grafton. This program consolidates TaT’s With the Aftermarket Expo in April, it’s almost a decade ago and online presence in a big way. going to be a very busy year. said, ‘Let’s start a magazine’, WI probably responded along the lines of The magazine will continue of course, but TaT is again heavily involved in Expo, ‘Find yourself another journo’. the real goodies are hidden behind the which is the biggest purely automotive website front page, accessible only to trade exhibition and seminar program in Magazines started with big ideas (and those who choose to pay the incredibly Australia.
    [Show full text]
  • Lucas Relays and Switches
    Lucas Relays TERMINATIONS GUIDE SRB502 Terminal designations Recommended Terminal definitions 1 x SRB500 Relay British DIN 72651 DIN 72552 Polarity 1 x Relay mounting block W2 1 86 + Start of winding 5 x 1/4" Lucar connectors W1 2 85 – End of winding to negative C1 5 87 N/O contacts C2 3 30 Switch Input C3 4 87a N/C contacts 87b N/O double contacts 87c N/O double contacts 86a Start of winding or 1st winding 86b Winding Tap or 2nd winding 88 Relay input (make-contact side) 88a 1st Output (make-contact side) 88b, c, d, e, f Other outputs (make-contact side) 88z 1st Input (make-contact) 88y, x 2nd & 3rd Input (make-contact) ™ Normally Open Contacts 15 Switched + from Battery # (output of ignition or start switch) Normally Closed Contacts 1 Ignition coil – Low voltage side ¢ Double Contacts 50 + Starter control (direct) 31 – Return to battery –ve (ground) ¡ Changeover Relay TD 12 V square wave input from ECU 51 + Positive output from Generator / Alternator 85b End of second winding 26RA ™ SRB402 12 V 20 A STANDARD 30/51 85 86 87 30/51 85 86 87 ¢ SRB400 12 V 20 A STANDARD 30/51 87A 85 86 87 30/51 85 86 87 87A ¡ SRB411 12 V 20 A STANDARD 30/51 87A 85 86 SRB420 24 V 10 A STANDARD 87 30/51 85 86 87 87A 3.2 Lucas Relays 6RA ™ SRB111 12 V 20 A NEOPRENE W1 C1 C2 SRB201 24 V 10 A STANDARD W2 C2 W1 W2 C1 C1 SRB113 12 V 20 A NEOPRENE C1 W1 C2 W2 C2 W1 W2 C1 # SRB131 12 V 20 A NEOPRENE W2 W1 C2 SRB220 24 V 10 A NEOPRENE C3 GDB GS C2 W1 W2 C3 PFK SFK ¡ SRB143 12 V 20 A STANDARD C1 W1 C2 SRB146 12 V 20 A STANDARD C3 W2 C2 W1 W2 C1 C3 SRB230 24 V 10 A NEOPRENE Split Charge Relays 39RA ™ 86 SRB600 12 V 60 A STANDARD CONTINUOUS 30 85 G SRB601 24 V 40 A STANDARD CONTINUOUS SRB631 12 V 60 A STANDARD INTERMITTENT 30 85 86 G SRB632 24 V 40 A NEOPRENE INTERMITTENT ¢ SRB630 12 V 60 A STANDARD CONTINUOUS W1 W2 C3 C2 C1 C1 W1 W2 C2 C3 SRB630 is suitable for charging two independent batteries from a single source.
    [Show full text]
  • 50020468C D250SE-SMARTPASS 120S, Manual, Print File 001.Indd
    12V USER MANUAL FULLY AUTOMATIC FULLY FOR LEAD-ACID ANDLITHIUM-IONBATTERIES SYSTEM MANAGEMENT AND 12VPOWER CHARGER CTEK DC/DCBATTERY D250SE SMARTPASS 120S SMARTPASS 2 YEAR WARRANTY ZH KO JA PL FI NO DA SV NL IT ES FR DE EN MANUAL CONGRATULATIONS D250SE on the purchase of your new CTEK charger providing professional battery care. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest Input Solar panel Earth Connection technology in battery charging. With the CTEK D250SE and SMARTPASS 120S you can be sure of +IN getting maximum performance from your dual battery system. EN SAFETY Temperature sensor 2 m/6 ft. CALIFORNIA PROPOSITION 65 WARNING: This product contains chemical known to the state of California to cause cancer or reproductive toxicity. Smart alternator cable (red) 0.2 m/0.6 ft. • The D250SE and SMARTPASS 120S have been developed for 12V lead-acid and LFP batteries. Battery select cable (black) Do not use the unit for any other type of battery. • Wear protective goggles when connecting and disconnecting batteries. 0.2 m/0.6 ft. • Battery acid is corrosive. Rinse with plenty of water immediately if you get acid on your skin or in your eyes. Get medical assistance. • Never use a charger with damaged electric cables. Check that the cables have not been dama- +IN Input Alternator +OUT Output Service battery ged by hot surfaces, sharp edges or in any other way. • Explosive gases are generated while lead-acid batteries are being charged. Avoid any sparking near the battery.
    [Show full text]
  • Who Is Making That Terrible DIN?
    Who is making that terrible DIN? Undoubtedly there are those amongst us who cannot sleep at night because they wonder what the numbers on the bottom of Automotive Relays actually mean. You have seen them. The relay coils are labelled 85 and 86. Contacts are labelled 30, 87 and 87a. Who got to say What the numbers were? Why are we still stuck with them? Is it really the relay numbers that prevent you from sleeping? Set the wayback machine to 1917 when the German Institute for Standardisation (Deutsches Institut für Normung) was formed, who’s name was translated and abbreviated to DIN standards. Then fast-forward to when they announced DIN standard 72552 Electrical terminal numbers in automobiles. Yes, there is a list for the designation of almost every wire within a car. They successfully persuaded the auto relay manufacturers to continue to put these codes on their relays, even though they have forgotten why. Sure it is likely that motor vehicle electrics have moved on somewhat since 1917, but don’t hold your breath waiting for the numbers to disappear from the bottoms of Chinese made relays displayed on your supermarket peg board. The DIN 72552 CODE Code Wire Function 1 Coil, distributor - low voltage 1a To contact breaker I (distributor with 2 separate circuits) 1b To contact breaker II (distributor with 2 separate circuits) 2 Shorting circuit - magneto ignition 4 Coil, distributor - high voltage 4a From coil I (distributor with 2 separate circuits) 4b From coil II (distributor with 2 separate circuits) 7 Ballast resistor terminal to/from
    [Show full text]
  • High Voltage Components in Commercial Vehicles
    HIGH VOLTAGE COMPONENTS IN COMMERCIAL VEHICLES Turska Matti Thesis Technology, Communication and Transport Electrical Engineering Bachelor of Engineering 2017 Opinnäytetyön tiivistelmä Tekniikka ja liikenne Sähkötekniikan koulutusohjelma Insinööri (AMK) Tekijä Ins. (AMK) Matti Turska Vuosi 2017 Ohjaajat Ins. (AMK) Aila Petäjäjärvi (Lapin AMK) Ins. (AMK) Tero Rajaniemi (PKC) Toimeksiantaja PKC Wiring Systems Oy Työn nimi High Voltage Components in Commercial Vehicles Sivu- ja liitesivumäärä 80 + 7 Opinnäytetyön tavoitteena oli selvittää, minkälaisia vaatimuksia ajoenergian siirtoon ja varastointiin käytetty korkeajännite asettaa hyötyajoneuvojen johdinsarjoille komponentteineen sekä sähkökeskusten toimilaitteille. Opinnäytetyössä käsiteltiin sähköajoneuvojen mukanaan tuomia haasteita ja mahdollisuuksia sekä jännitetasojen eroavaisuuksia teollisuus- ja ajoneuvopuolella. Lisäksi käsiteltiin lyhyesti erilaisia latausmetodeja sekä alan standardisointia. Työ tehtiin PKC Wiring Systems Oy:lle. Korkeajännitejärjestelmässä käytettäviä komponentteja ja niiden ominaisuuksia käsiteltiin siten, että lopputuloksesta muodostuu yleiskäsitys uusista vaatimuksista. Keskeisimpänä ominaisuutena olivat henkilöturvallisuusnäkökohdat sekä suunnittelussa ja materiaalivalinnoissa huomioonotettavat asiat toimittaessa korkeajänniteympäristössä. Yrityksen sisäiseen käyttöön tarkoitetussa osiossa laadittiin lyhyt tekninen analyysi korkeajännitekomponentteja sisältäneistä tarjouskyselyistä. Näiden pohjalta tehtiin ehdotuksia mihin osa-alueisiin tulisi panostaa, mikäli
    [Show full text]
  • Datasheet Micro Plc Can 1.107 Mrs Electronic Technical
    MRS ELECTRONIC DATASHEET MICRO PLC CAN 1.107 DESCRIPTION The Micro PLC CAN is a small control system for automotive ap- plications. Free configuration and programmability offer a wide ran- ge of applications in the automo- tive sector. Control and readout are done via the CAN bus (ISO 11898-2). Freescale Processor with Flash technology (option of multiple programming). Mouting direction View of plug TECHNICAL DATA REGULATORY APPROVALS AND TESTINGS Housing Plastic PA66GF30 E1 Approval ECE R10 05 7362 (for variants with VNQ5050) Connector Base plate 9-pin e1 approval 03 6211 (Relay and BTS442) Weight 31 g Electrical tests According to ISO 16750 – 2 or -4: Ambient temperature -40°C to +85 °C (at +85 °C not Short circuit protection (according to ISO 16750- full load) Jump-start (12 V variants) 4) Reverse polarity test Environmental Protection IP 53 Interruption pin und plug Long-term overvoltage at TMax-20 °C Current consumption 27 mA Storage test at TMax and TMin Protection Depending on the variety of Operation test at TMax und TMin available configurations: Overlaying AC voltage cf. p. 7/8 Low sink and rise of supply voltage Voltage drop Total inputs and outputs Depending on the variety of avai- Reset behaviour at voltage drop lable configurations: According to ISO 7637 - 2: Puls 1, 2a, 2b, See p. 7/8 3a, 3b Inputs Configurable as: Analogue input (0 ... 11,4 V) Digital, positive encoder signal SOFTWARE/PROGRAMMING frequency input Outputs Configurable as: Programming System Digital, positive switching (high- side or relay output) MRS Developers Studio PWM output (3 Hz ..
    [Show full text]
  • White Paper 4 Understanding Electrical Overstress - EOS
    White Paper 4 Understanding Electrical Overstress - EOS Industry Council on ESD Target Levels August 2016 Revision 1.2 Industry Council on ESD Target Levels 1 This document is available through various public domains as listed below: The Industry Council on ESD http://www.esdindustrycouncil.org/ic/en/ The Electrostatic Discharge Association http://www.esda.org/ JEDEC – Under Publication JEP174 http://www.jedec.org/ Industry Council on ESD Target Levels 2 Abstract Damage signatures from Electrical Overstress (EOS) are the leading reported cause of returns in integrated circuits and systems that have failed during operation. Solutions to this problem are hindered by a prevailing misconception in the electronics industry that insufficient robustness to electrostatic discharge (ESD) is a primary cause of EOS. This document, White Paper 4, (WP) has been carefully compiled by the Industry Council on ESD Target Levels to foster a unified global understanding of what constitutes EOS and how EOS damage signatures can result from a wide variety of root causes. The paper begins by outlining a brief history of EOS. It then presents the results of an industry-wide EOS survey. This survey gathered information on the types of EOS problems experienced by over 80 different companies, the relative importance of EOS to their overall business, and the methods assigned by these companies to address EOS issues. The survey provides a combined picture from which a more comprehensive definition of EOS can be made. The numerous categories and sub- categories of EOS root causes are explored in an attempt to understand how to create better specifications which will reduce their occurrence.
    [Show full text]