Resuscitation

Index

1. Introduction: 2. Incidence and risk factors Need for resuscitation Antenatal prediction of need for resuscitation 3. Consequences: Complications of neonatal resuscitation 4. Equipment needed for resuscitation 5. Algorithm for neonatal resuscitation Assessment at delivery Minimise heat loss Suctioning of the airway Assisted ventilation Tracheal intubation Combined external cardiac compression and assisted ventilation Assess response Failure to respond to resuscitation Vascular access 6. Drugs in resuscitation 7. Volume replacement in resuscitation 8. Cord blood sampling 9. Management after resuscitation 10. Cessation of cardiopulmonary resuscitation 11. Key points 12. References

1. Introduction:

Effective resuscitation of the newborn infant requires adequate training and preparation of staff involved in the care of women in labour, a knowledge of maternal and intrapartum risk factors that may influence the postnatal course of the infant, and adequate and functioning equipment for resuscitation of the newborn. "As poor cardiorespiratory adaptation at birth (low Apgar scores) cannot be predicted in the majority of cases, all staff involved in care during labour should be skilled in resuscitation of 1 the newborn".

2. Incidence and risk factors:

Need for resuscitation:In 2009 in Australia, a total 294,540 women gave birth to 299,220 babies. There were 296,791 live births and 2,341 fetal deaths. 8.2% of babies were born preterm (before 37 completed weeks of gestation) and 0.9% post-term (42 weeks gestation or more). Most women (68.5%) had a vaginal birth, and of these, 82.9% did not involve the use of instruments. Overall, 31.5% of women gave birth by caesarean section. Overall, 6.2% of live born babies were of low birth weight (less than 2,500 grams). Less than 1.5% of live born babies had a low Apgar score. The perinatal death rate was 9.8 per 1,000 births in 2009, which comprised fetal and neonatal death rates of 7.8 per 1,000 births and 3.0 per 1,000 live births respectively.2.

Suction and oxygen therapy were the most common types of resuscitation used. Just over one-quarter (28.1%) of babies required some form of resuscitation at birth, although most of these babies (71.3%) required only suction or oxygen therapy. Ventilatory assistance by intermittent positive pressure respiration (IPPR) through a bag and mask or after endotracheal intubation was performed for at least 7.2% of all live births. External cardiac massage and ventilation was provided for a minority of babies (0.3%).2.

Antenatal prediction of need for resuscitation: only about half of the infants needing resuscitation are predicted by antenatal history or signs during labour1,3. International guidelines on neonatal resuscitation4 and College guidelines5 state that an appropriately trained practitioner should be present at all births (including caesarean section) and an advanced skills practitioner present for high risk deliveries. Assessment should include a history of maternal and intrapartum risk factors that may affect the infant including pre-existing medical conditions in the mother, problems of , abnormalities identified antenatally in the fetus, the presence of meconium stained liquor, CTG abnormalities, scalp pH or lactate, maternal indicators of infection, presentation and method of delivery.

Neonatal medical/ NNP staff should attend all high-risk deliveries including:

Preterm infants < 35 weeks gestation6 Multiple births Infants with significant congenital malformation diagnosed antenatally Abnormal CTG or scalp pH < 7.21 or scalp lactate > 4.2mmol/L7, 8 Thick (particulate) meconium stained liquor Breech delivery Instrumental delivery (not uncomplicated low forceps or vacuum lift- out) Caesarean section under general anaesthetic Emergency caesarean section Opioids administered to the mother within 4 hours of delivery Other situations where there is concern of infant compromise

Deliveries requiring attendance of an advanced skills practitioner - HDU registrar / tNNP:

All those requiring neonatal medical / tNNP staff attendance until their basic resuscitation training is assessed as competent. Delivery <33 weeks gestation6 Category 1 and 2/30 urgent caesarean sections Thick (particulate) meconium stained liquor present in early labour or associated with abnormal CTG or scalp pH < 7.21 or scalp lactate > 4.2 mmol/L7, 8 Known maternal condition or fetal abnormality with potential to affect adaptation Other situations where there is concern of infant compromise

Deliveries requiring attendance of neonatal Fellow or Consultant on duty:

Delivery <30 weeks, Prolonged fetal bradycardia (<100 for >5 minutes), Known severe fetal abnormality Other situations as requested by obstetric or neonatal staff

3. Consequences:

Complications of neonatal resuscitation: reported complications from appropriately applied resuscitative techniques are uncommon in neonates and infants.9, 10 The potential benefits of appropriately applied resuscitative techniques far outweigh any potential harm. Infants should be surveyed for potential injury post resuscitation particularly airway injury after difficult intubation attempts11 and rib and organ injury after chest compressions.10, 12, 13

4. Equipment needed for resuscitation: This should be functionally checked immediately before all newborn resuscitation. (Remember Heat Oxygen Light Suction).

1. Radiant warmer 2. oximeter and probe 3. Warm towel and blankets 4. Polyethylene wrap for infants <28 weeks or <1500g 5. An interruptible t-piece Neopuff is the primary method of IPPV for resuscitation at RPA: preset peak inspiratory pressure (PIP) 20 cmH2O; end expiratory pressure (EEP) 5 cmH2O [relief valve maximum pressure 40 cmH2O]. 6. Resuscitation bag and mask: 1. All resuscitaires should have a self-inflating bag (infant Laerdal) which needs a reservoir attached to deliver more than 40-60% oxygen. The pop-off valve (set at 35cmH2O) varies greatly in maximal pressure delivered before the valve automatically opens. They do not provide positive end expiratory pressure. 2. The resuscitation mask should comfortably cover the mouth and nose whilst sitting on top of the chin. Circular silicone masks result in less air-leak1414 and are easier to clean. 7. Endotracheal tubes size 2.0, 2.5, 3.0, 3.5, 4.0 (see tube sizes and lengths) 8. Laryngoscopes (as a guide, size 00 for under 27/40s, 0 for 27/40s to 32/40s, 1 for infants over 32/40) 9. Stethoscope 10. Pedi-Cap end-tidal CO2 detector. 11. Oxygen source and tubing use piped / wall oxygen / air with blender preferentially. Check oxygen / air bottles have adequate supply for transport. 12. Low flow suction source (set 100 mmHg),15 tubing and size 10 FG Y-suction catheter and meconium aspirator. 13. Magill forceps for tracheal intubation (especially by the nasal route) 14. Surfactant administration - infant feeding catheter 3-5FG, tape measure, surfactant, 5 ml syringe and drawing up needle (see surfactant guidelines) as required 15. Meconium aspirator

In addition, the following equipment should be available, replaced after use and checked each shift:

1. Adrenaline 1:10 000 ampoule 2. Syringe and drawing up needles 3. Normal saline ampoule and normal saline fluid bag 4. Umbilical catheter (3.5 and 5 FG); linen tie; tape; 3-way tap 5. Dressing pack and sterile gloves

5. Algorithm for neonatal resuscitation:

a. Assessment at delivery: Newborn infants who do not require resuscitation can generally be identified by a rapid assessment of the following 3 characteristics:4

Term gestation? Crying or ? Good muscle tone?

If the answer to all 3 of these questions is yes, the baby does not need resuscitation and should not be separated from the mother. The baby should be dried, placed skin-to-skin with the mother, and covered with dry linen to maintain temperature. Observation of breathing, activity, and colour should be ongoing.4

Dry and stimulate the infant after delivery. The Apgar score16 is used to document postnatal adaptation at 1and 5 minutes (and at 10, 15 and 20 minutes if < 8 at 5 minutes). It includes: Heart rate, respiratory efforts, tone, reflex irritability and colour, which guide resuscitation.

Assessment of should be done by intermittently auscultating the precordial pulse. When a pulse is detectable, of the umbilical pulse can also provide a rapid estimate of the pulse and is more accurate than palpation at 4 other sites.

Infants with low Apgar scores, or persisting and/or bradycardia and/or irregular respiratory effort should receive assistance.4

Infants with both blue (1O) apnoea (apnoeic, flaccid and cyanosed with heart rate < 100 bpm; Apgar score = 1), and white (2O) apnoea (apnoeic, flaccid and pallid with heart rate < 100; Apgar score = 1) can be recognised almost immediately after birth17, 18 and resuscitation commenced without delay.

b. Minimize heat loss:

Prevention of cooling reduces the mortality of low birth weight infants.19-24 Infants gain and lose heat by 4 modalities: evaporation, radiation, convection and conduction. Steps taken in the delivery room to prevent heat loss that have been shown to be effective include:

1. If resuscitation is not required - early skin to skin contact with mother under warm blankets in term infants.25, 26 2. Dry the infant (and wrap in warm blankets when resuscitation completed) 3. Radiant heater 4. Polyethylene wrap for infants <28/40 or <1500g4 (see thermoregulation guideline) 5. Plastic covering when moving the resuscitaire.

Avoid overheating, particularly with infants wrapped in polyethylene under radiant heaters. Infant temperature should be monitored carefully as soon as the infants is stabilised with initial resuscitation. Hyperthermia has been associated with exacerbation of cerebral injury following ischaemic injury in animal studies6; infants born to febrile mothers have been found to have an increased risk of death, respiratory depression, and cerebral palsy.27

In term asphyxiated infants, therapeutic cooling improves outcome reducing mortality and disability.28 If an infant meets criteria for cooling, this should be discussed after initial stabilisation. See Moderate systemic hypothermia for the treatment of neonatal hypoxic ischaemic encephalopathy (HIE) guideline. If the baby is not cooled, overheating should be avoided.

c. Suctioning of the airway:

There is no evidence to support routine suctioning of the upper airway or stomach in newborn infants and reports of injury indicate the potential for harm.15, 29 Suctioning of the upper airways should be restricted to who have obvious obstruction to spontaneous breathing.

Meconium stained liquor: Suctioning as the head delivers when meconium is present is no longer routinely recommended as a large multicentre randomised trial has shown this makes no difference to outcome.30 However if thick meconium appears to be in the mouth causing obstruction, it should be suctioned out. Suctioning below the cords when thick meconium is in the liquor: In the absence of randomized, controlled trials, there is insufficient evidence to recommend a change in the current practice of performing endotracheal suctioning of non-vigorous babies with meconium-stained amniotic fluid. However, if attempted intubation is prolonged and unsuccessful, bag-mask ventilation should be considered, particularly if there is persistent bradycardia.29 If the baby is vigorous and breathing established, do not attempt to suction below the cords as there is evidence that this does not reduce the incidence or severity of meconium aspiration and may do harm.31

d. Assisted ventilation:

Effective ventilation is the most important part of neonatal resuscitation in an infant that has not established regular breathing and good heart rate following initial drying and stimulation.

In an RCT, there was no significant difference in SpO2 at 5 minutes after birth in infants < 29 weeks gestation given PPV with a T-piece or a self inflating bag.32

Start with interrupted t-piece intermittent positive pressure ventilation (IPPV):

The mask should cover the mouth and nose, but not be as high as the eyes and it should sit below the mouth on the chin. There should be a good seal. The head position should be neutral or sniffing (not overly extending the neck), with jaw thrust if needed to help open the airway. 29 Ventilate at 30 60 breaths per minute PIP 20 cmH2O EEP 5cmH2O. If heart rate and colour do not improve with mask IPPV, check that the airway is adequate (appropriate head position) and the seal of the mask is good, and that the chest is moving higher inflation pressures may be needed. If mask IPPV is not producing a response, intubation could be attempted. Call for assistance. Although current neonatal resuscitation guidelines recommend using visual assessment of chest wall movements to guide the choice of inflating pressure during positive pressure ventilation, observers tended to underestimate tidal volume by 3.5mL and agreement between clinical assessment and measured V(Te) was generally poor.33

Oxygen use with ventilation (IPPV and mask or via endotracheal tube):

Oximetry should be used when resuscitation can be anticipated, when positive pressure is administered for more than a few breaths, when cyanosis is persistent, or when supplementary oxygen is administered.34 Place a pulse oximeter on the right arm/hand (preductal SpO2). Applying the sensor to the infant before connecting it to the cable yields the fastest acquisition of accurate HR data.35 Preductal targeting of SpO2 should approximate physiological levels see targeted preductal SpO2 after birth Figure Newborn Resuscitation Algorithm. For term and near term infants (32-36 weeks weeks): Start in air and adjust clinically as needed increasing after 30 seconds if there is a poor response, and decreasing as able as colour/oxygen saturations improve (see below). Conflicting meta-analyses come to different conclusions regarding evidence for use of air versus oxygen for initial resuscitation.36, 37 Meta-analysis of 8 controlled trials (1,500 patients) reported the evidence is based mainly on quasi-randomized studies with unblinded resuscitators and found no significant difference in death (RR 1.35, 95% CI 0.97 to 1.88; P = 0.08), hypoxic/ischemic encephalopathy (RR 1.03, 95% CI 0.86 to 1.23; P = 0.74), or requiring tracheal intubation was (RR 0.85, 95% CI 0.69 to 1.05; P = 0.12).37 For very preterm infants 9<32 weeks): Start in 30(-40%) FiO2 and adjust clinically as needed increasing after 30 seconds if there is a poor response, and decreasing as able as colour/oxygen saturations improve (see below). Titrating from an initial oxygen concentration of 100% was more effective than giving a static concentration of 100% oxygen in maintaining preterm infants in a target oxygen saturation range.38 Initiating resuscitation with 21% oxygen resulted in a high treatment-failure rate.38, 39 However, Use of oximetry targeting allows for physiological targeting of oxygen in preterm infants with small trials suggesting starting 40, 41 at 30% instead of 90% and titrating results in appropriate SpO2 targeting in most infants. 42 A preliminary meta-analysis of trials of lower versus higher early SpO2 targeting found higher survival rates at 36 weeks postmenstrual age in infants born <28 weeks of gestation and randomly assigned to oxygen saturation (SpO2) targets of 91 to 95% rather than 85 to 89% while breathing supplemental oxygen. Until longer-term data on survival and morbidity are available, it is prudent not to target a SpO2 85 to 89% in infants born earlier than 28 weeks of gestation.42

e. Tracheal intubation:

Indications for endotracheal tube intubation include:

Tracheal suctioning for meconium if infant born through thick meconium and non-vigorous (no respiratory effort)4 Failure to provide adequate ventilation using a bag and mask despite adequate attempts at obtaining an airway4 Prophylactic surfactant (infants born <27 weeks gestation)43 (see preterm and term surfactant guidelines) Respiratory distress44, 45 likely to require continued ventilatory support (see preterm and term surfactant guidelines) Congenital abnormalities as indicated (eg diaphragmatic hernias)4

Endotracheal tube size and placement: see guide to ETT size and distances based on infant weight. ETT 2.5 can be used for infants up to 1.4kg; ETT 3.0 1.0 -2.0kg; ETT 3.5 1.9 3.7kg; ETT 4.0 - 3.7kg+.

As a rough guide, use a 2.5 ETT for most babies 28/40 or less, a 3.0 would suit most 29 – 31/40 and a 3.5 for 32 weeks and above. Tube placement should always be checked clinically as detailed below. Once stabilised a chest x-ray should be done to check placement as well as for condition of the lungs, air leaks etc.

Checking position of the ETT:

Ensure you see the ETT going through the cords; insert to 2cm (slightly less in infants <750g) which is the end black mark (2cm). A PediCap or respiratory function monitor can be used to assist in assessing ETT placement. An observation study reported both methods correctly identified successful ETT placement in 21/35 (60%) intubations, in 3 (9%) both indicated the ETT was not in the trachea, in the remaining 11 (31%) the PediCap failed to change colour despite the flow wave indicating correct ETT placement. Colorimetric CO2 detectors may fail to change colour in spite of correct tube placement in up to one third of the cases. Listen for air entry in each side of the chest; if the tube is too far down (usually it would be down the right main bronchus) there will be decreased breath sounds on the unventilated side (usually the left) withdraw the ETT until breath sounds are equal. No single technique is without limitations and clinicians should utilize a combination.46 If there is doubt as to whether it is in the trachea despite the measures above, look again with a laryngoscope to see if the tube is through the cords.

f. Combined external cardiac compression and assisted ventilation:

Check for pulse: either by ,4 palpating umbilical arteries or . Perform cardiac massage: if initial heart rate after initiation of ventilation is < 60-bpm4 or remains 60-80 bpm after initiation of adequate ventilation.

Chest compression:

Compressing the lower half of sternum either by: Encircle the chest with both hands and use 2 thumbs (higher and better coronary perfusion in pigs47) preferred method;4 or by: Using 2 fingers over the lower sternum. The 2-finger technique may be preferable when access to the umbilicus is required during insertion of an umbilical catheter.4 Avoid the chest margins and xiphisternum and do not restrict chest re-expansion. Compress the chest 1/3rd of its depth4

Provide chest compression in combination with ventilation:

There should be at least 90 compressions and 30 breaths per minute, with a ratio of 3 compressions with 1 breath (ie 3:1 ratio: c-c-c-v-c-c-c-v-c-c-c-v).4

g. Assess the response:

Reassess the response to ventilation every 30-60 seconds Continue to ventilate until there is an adequate response crying or adequate sustained spontaneous breathing and heart rate > 100 bpm With infants receiving coordinated chest compressions and ventilations, Respirations, heart rate, and oxygenation should be reassessed periodically, and coordinated chest compressions and ventilations should continue until the spontaneous heart rate is 60 per minute. Frequent interruptions of compressions should be avoided, as they will compromise artificial maintenance of systemic perfusion and maintenance of coronary blood flow.4

h. Failure to respond to resuscitation:

If there is an initial heart beat this is usually due to inadequate ventilation If bag and mask ventilation: ensure an adequate airway (chin lift and slight head tilt) Failure to respond to bag and mask ventilation is an indication for intubation. If endotracheal tube: usually a misplaced endotracheal tube (ie oesophageal). See Checking position of the ETT. If the above have been checked and optimised and there is inadequate response, then there may be blocked endotracheal tube, blocked airway or severe lung disease. Change tube under suction. Preterm infants with surfactant deficiency may respond to surfactant treatment. Deterioration after initial response to resuscitation may indicate a misplaced endotracheal tube or air leak. Consider the possibility of anatomical anomalies or pleural effusions (suggested by antenatal findings). If none of the above then increase ventilatory effort and follow Newborn Resuscitation Algorithm Call for assistance

i. Vascular access:

Use umbilical vein where possible, Alternative routes include: peripheral vein (eg scalp vein), femoral vein, or endotracheal (ETT) routes for adrenaline. The umbilical artery and subclavian veins should be avoided where possible due to the potential complications of these routes.

6. Drugs in resuscitation:

Summary:

Adrenaline is the most commonly used drug in newborn resuscitation and is included in the ILCOR resuscitation algorithm. However, its reported use is for <1 per 1000 deliveries. Hypovolaemia is difficult to diagnose but must be considered in specific situations and when there is a failure of response to resuscitation measures despite adequate ventilation. Volume expansion (normal saline or blood) is reported in 1 per 12 000 deliveries. The other agents are rarely indicated for newborn resuscitation but may have a roll in post-resuscitation care.

a. Adrenaline:

The recommended IV dose is 0.01 to 0.03 mg/kg per dose.4 Higher IV doses are not recommended because animal and paediatric studies show exaggerated hypertension, decreased myocardial function, and worse neurological function after administration of IV doses in the range of 0.1 mg/kg.

If the endotracheal route is used, doses of 0.01 or 0.03 mg/kg will likely be ineffective. Therefore, IV administration of to 0.03 mg/kg per dose is the preferred route. While access is being obtained, administration of a higher dose (0.05 to 0.1 mg/kg) through the endotracheal tube may be considered, but the safety and efficacy of this practice have not 4 been evaluated.

Dosage regimen used at RPA:

1. Adrenaline 0.03 mg/kg intravenously via UVC = 0.3 ml/kg of 1:10000 adrenaline, or 2. If unable to obtain rapid venous access give: adrenaline 0.1 mg/kg via ETT = 1 ml/kg of 1:10000 adrenaline.

Repeat dose once if no response after 60 seconds.

b. Naloxone:

This should only be considered in infants who are depressed by opiates once an infant has first been stabilised with 4 ventilatory support, and has good heart rate and colour.

DO NOT give Naloxone to infants of narcotic dependent mothers. It can precipitate acute withdrawal.

Opiates given to the mother in labour (within 4 hours of delivery), can affect the infants drive to breathe at the time of delivery, and possibly in the first few hours of life. If a mother has received Pethidine, the infant needs close observation for at least the first 4 hours of life (see Observation And Management Of Newborn Infants With Respiratory Maladaptation To Birth, Including Infants Exposed To Intrapartum Opioids Administered To The Mother During Labour Policy). It is yet to be demonstrated that use of Naloxone in opiate exposed newborns can reduce the need for admission to NICU or mechanical ventilation.48 The half life of Naloxone is shorter than pethidine, so close observation is particularly important in infants who have received this to ensure apnoea does not occur as the effect of Naloxone wears off.

Dose: Naloxone 100 µg/kg via intravenous or intramuscular injection (preferred)49. For term or near term infants, if weight is not known, then give 0.5ml of Naloxone 400µg/ml (ie 200µg).

Naloxone is quick acting and should work within a couple of minutes of giving it. Effect after giving this IM is only slightly delayed compared with IV.

c. Bicarbonate:

A single trial of intravenous infusion of sodium bicarbonate to newborn babies during resuscitation in the delivery room at 50 birth did not show any benefit of the use of this drug immediately after birth, nor any adverse effects.

Bicarbonate should be restricted to post-resuscitation correction of acidosis. See acidosis guideline. Obtain an early blood gas after resuscitation. If there is a significant metabolic acidosis the dose is: 4.2% NaHCO3 ml = 0.3 x weight kg x BE given over 30-60 minutes.

d. Dextrose:

Glucose has not been shown in animal models or adult humans to change the outcomes of cardiopulmonary resuscitation.51, 52 No trial of glucose versus no glucose for resuscitation exists for neonates.

Neonates requiring CPR should have an early blood sugar estimate after resuscitation and correction of hypoglycaemia if BSL < 2.0 mmol/L (see hypoglycaemia guideline). e. Calcium and Atropine:

There is no evidence to support the use of these agents during neonatal resuscitation.

7. Volume replacement in resuscitation:

Hypovolaemia is difficult to diagnose in the neonate. Volume expansion should be considered when blood loss is known or suspected (pale skin, poor perfusion and weak pulse) and the babys heart rate has not responded adequately to other resuscitative measures.4 An isotonic crystalloid solution or blood is recommended for volume expansion in the delivery room.4

Significant hypovolaemia should be strongly considered in the following situations:

Pale infant with tachycardia, especially if preceded by Vasa praevia53 or Feto-placental haemorrhage54 (when there is cutting of a nuchal cord on delivery of the head and the cord is cut before placenta-fetal transfusion can occur after delivery), or Feto-maternal haemorrhage55. Suspect if sinusoid CTG trace and/or raised middle cerebral artery peak systolic velocity on fetal ultrasound.56 Order maternal QFMH. Placental trauma (accidents and at caesarean when cutting through an anterior placenta with subsequent delayed delivery) Acute twin-twin transfusion with uterine contractions57, 58 Note - Uterine rupture, antepartum haemorrhage and placental abruption is usually associated with fetal hypoxia59 and blood loss is commonly maternal.

Treatment:

Early and adequate blood volume replacement may improve outcome in fetal haemorrhagic shock. Give whole blood or packed red cells in 20 ml/kg aliquots titrated against response. Serial haematocrit may be used to determine adequacy of red cell replacement. Note initial haematocrit may be normal with acute blood loss. If hypovolaemia / poor output is suspected but blood is not immediately available: give Normal Saline 10-20 ml/kg over 10-30 minutes and titrate against response. There are no data to suggest that albumen or other volume expanders are superior to normal saline in hypotensive infants.60

Arrhythmias in neonates: these are rarely a primary problem at neonatal resuscitation. See arrhythmia and hyperkalaemia guidelines.

8. Cord Blood Sampling:

A cord gas should be taken for every baby who requires resuscitation. Take blood from an umbilical artery. There are two umbilical arteries that are smaller, muscular and blue (compared with one larger purple coloured umbilical vein). Sample from the placental surface if necessary (arteries go over the veins). An umbilical venous-arterial pH difference of 0.15 is an effective cutoff value in differentiating cord prolapse from abruptio placentae (accuracy 92%).61

Normal values for cord gases:62 Umbilical artery: Umbilical Vein: pH: 7.24 ± 0.07 [range pH: 7.32 ± 0.06 [range 7.37 7.10] 7.43 7.20] BE: -5.6 ± 3.0 mmHg BE: -4.5 ± 2.4 mmHg [range +0.3 to -11.5] [range +0.2 to -9.2]

Measures of hypoxia - pH <7.0 (important for diagnosis of HIE) - pH <7.10 (2SD below normal) 63 A blood gas is stable in syringe for 30 minutes With delayed sampling placental pH values fall at twice the rate as umbilical pH values.63

9. Management after resuscitation (see asphyxia):

Seek the cause of the arrest and treat specifically. Complications of the resuscitation procedure should be sought, including air leaks (pneumothorax, pneumomediastinum or pneumopericardium), oesophageal injury and blood loss from organ damage (eg liver). Obtain cord arterial and venous blood gas analysis (may be obtained from placental vessels - arteries cross veins). Perform Apgars at 1 and 5 and every 5 until Apgar > 7. Document time to sustained spontaneous respiration. Obtain early arterial blood gas and BGL. Correct persisting acidosis and hypoglycaemia. Respiratory support: continue ventilation till adequate sustained spontaneous respiration and without severe respiratory distress. Ventilate to ensure adequate oxygenation and normocarbia. Monitor vital organ function: cardiac dysfunction as determined by hypotension or poor cardiac output (ECHO); renal dysfunction (oliguria < 0.5 ml/kg/hour or creatinine 120mmol/L); hepatic dysfunction (abnormal LFTs); and cerebral dysfunction (hypoxic ischaemic encephalopathy and ). Avoid running high fluid rates in asphyxiated infants, as fluid retention may occur resulting in hyponatraemia. Monitor electrolytes.

10. Cessation of cardiopulmonary resuscitation:

Death or moderate to severe neurological abnormality is predicted by a failure to obtain a heart rate by 10 minutes (Apgar score10 is 0) despite adequate resuscitation and failure to respond to adrenaline. Although there are reported normal outcomes in babies with Apgar10 of 0, the large majority of such babies will die or have moderate to severe disability if they survive 62 In light of this, if the heart rate of a newly born baby is not detectable and remains undetectable beyond 10 mins, it is then appropriate to consider stopping resuscitation. The decision to cease resuscitation efforts is often complex and should only be made with the involvement of the most senior neonatologist on call. This decision may be influenced by issues such as the presumed aetiology, the gestation of the baby, the potential reversibility of the situation and duration of zero Apgar score when the decision to cease resuscitation is made. A search of the literature has failed to reveal a single infant with Apgar score of 0 at 10 minutes who was normal at follow up 6 with the majority not able to be resuscitated or becoming a neonatal death. Sample before 30 minutes from a clamped cord

11. Key Points

Key Point Rating

Newborn infants who do not require resuscitation can generally be identified by a rapid assessment of the following 3 characteristics: Term gestation; Crying or breathing; Good muscle tone. LOE 5 If the answer to all 3 is yes, the baby does not need resuscitation and should be dried, placed skin- to-skin with the mother, and covered with dry linen to maintain temperature.

If the infant is not term, crying or breathing or is floppy, the infant should be placed on a resuscitaire LOE 5 with radiant heater, dried and stimulated and assessed.

Normothermia is the goal. a. Hypothermia is associated with worse outcome in premature babies LOE 1a b. Hyperthermia exacerbates ischaemic cerebral injury. LOE 2 c. Use polyethylene wrap for premature babies under 28 weeks gestation LOE 1a

A person who is able to initiate basic life support should be present at every delivery. A person capable of advanced resuscitation should be present if there are risk factors for the infant LOE 5 to be compromised. Suctioning the oropharynx/nasopharynx is not routinely needed, including when liquor is meconium LOE 1b stained. GOR A However, suction if there is obstruction of the airway.

Do not suction below the cords when meconium is present if the baby is vigorous and breathing spontaneously. LOE 1a GOR A If the infant is born through thick meconium and is floppy and not breathing, consider suctioning the trachea. However, if attempted intubation is prolonged and unsuccessful, bag-mask ventilation should LOE 5 be instituted, particularly if there is persistent bradycardia,

Ventilation is the most important part of advanced resuscitation, and the majority of babies will LOE 5 respond to this alone.

If intermittent positive pressure ventilation is required:

In term and near term infants ( 32 weeks gestation) start in air (21% oxygen) and titrate to LOE 1a physiological preductal SpO2 (see algorithm) LOE 2b In very preterm infants (<32 weeks) start in 30% oxygen and titrate to physiological preductal SpO2 (see algorithm). Do not give supplementary oxygen if SpO2 >95%.

If the heart rate is <60 bpm, correct ventilation and commence 3:1 cardiac compressions : breath using encircling method. Rate 120 events per minute. LOE 5 Reassess every 30 seconds and stop compressions when heart rate >60 bpm or infant has return of tone, breathing or circulation.

Adrenaline 0.03 mg/kg intravenously via UVC = 0.3 ml/kg of 1:10000 adrenaline, or If unable to obtain rapid venous access give: adrenaline 0.1 mg/kg via ETT = 1 ml/kg of 1:10000 LOE 5 adrenaline

References

1. Perinatal morbidity. Report of the Health Care Committee Expert panel on Perinatal Morbidity. National Health and Medical Research Council. Australian Government Publishing Service; 1995.

2. Li Z, McNally L, Hilder L, Sullivan EA. Australias mothers and babies 2009. Perinatal statistics series no. 25. Cat. no. PER 52. Sydney. AIHW National Perinatal Epidemiology and Statistics Unit. 2011.

3. Tyson JE. Immediate care of the newborn infant. In: Sinclair JC, Bracken MB, editors. Effective care of the newborn infant: Oxford University Press; 1992. p. 21-39.

4. Kattwinkel J, Perlman JM, Aziz K, Colby C, Fairchild K, Gallagher J, Hazinski MF, Halamek LP, Kumar P, Little G, McGowan JE, Nightengale B, Ramirez MM, Ringer S, Simon WM, Weiner GM, Wyckoff M, Zaichkin J. Part 15: neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2010;122:S909-19.

5. Responsibility for Neonatal Resuscitation at Birth. College Statement. The Royal Australian and New Zealand College of Obstetricians and Gynaecologists. 2012:C-Obs 32.

6. Patel H, Beeby PJ, Henderson-Smart DJ. Predicting the need for ventilatory support in neonates 30-36 weeks' gestational age. Journal of paediatrics and child health. 2003;39:206-9.

7. Allen RM, Bowling FG, Oats JJ. Determining the fetal scalp lactate level that indicates the need for intervention in labour. The Australian & New Zealand journal of & gynaecology. 2004;44:549-52.

8. Wiberg-Itzel E, Lipponer C, Norman M, Herbst A, Prebensen D, Hansson A, Bryngelsson AL, Christoffersson M, Sennstrom M, Wennerholm UB, Nordstrom L. Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trial. BMJ. 2008;336:1284-7. 9. Ryan MP, Young SJ, Wells DL. Do resuscitation attempts in children who die, cause injury? Emergency medicine journal : EMJ. 2003;20:10-2.

10. Matshes EW, Lew EO. Do resuscitation-related injuries kill infants and children? The American journal of forensic medicine and pathology. 2010;31:178-85.

11. Garten L, Salm A, Rosenfeld J, Walch E, Buhrer C, Huseman D. Dysphonia at 12 months corrected age in very low- birth- weight-born children. European journal of pediatrics. 2011;170:469-75.

12. Matshes EW, Lew EO. Two-handed cardiopulmonary resuscitation can cause rib fractures in infants. The American journal of forensic medicine and pathology. 2010;31:303-7.

13. Haase R, Hinz L, Lieser U, Schmidt V, Milzsch M, Merkel N. [Liver rupture in preterm infants with a gestational age < 28 weeks]. Zeitschrift fur Geburtshilfe und Neonatologie. 2008;212:53-6.

14. Palme C, Nystrom B, Tunell R. An evaluation of the efficiency of face masks in the resuscitation of newborn infants. Lancet. 1985;1:207-10.

15. Alur P, Liss J, Ferrentino F, Super DM. Do bulb syringes conform to neonatal resuscitation guidelines? Resuscitation. 2012;83:746-9.

16. Apgar V. A proposal for a new method of evaluation of the newborn infant. Current researches in anesthesia & analgesia. 1953;32:260-7.

17. Nadkarni V, Hazinski MF, Zideman D, Kattwinkel J, Quan L, Bingham R, Zaritsky A, Bland J, Kramer E, Tiballs J. Pediatric resuscitation: an advisory statement from the Pediatric Working Group of the International Liaison Committee on Resuscitation. Circulation. 1997;95:2185-95.

18. Dawes GS. Fetal and neonatal physiology. Chicago: Year Book Medical Publishers; 1968.

19. Conde-Agudelo A, Belizan JM, Diaz-Rossello J. Kangaroo mother care to reduce morbidity and mortality in low birthweight infants. Cochrane Database Syst Rev. 2011:CD002771.

20. Silverman WA, Balnc WA. The effect of humidity on survival of newly born premature infants. Pediatrics. 1957;20:477-86.

21. Silverman WA, Fertig JW, Berger AP. The influence of the thermal environment upon the survival of newly born premature infants. Pediatrics. 1958;22:876-86.

22. Day RL, Caliguiri L, Kamenski C, Ehrlich F. Body Temperature and Survival of Premature Infants. Pediatrics. 1964;34:171- 81.

23. Buetow KC, Klein SW. Effect of Maintenance of "Normal" Skin Temperature on Survival of Infants of Low Birth Weight. Pediatrics. 1964;34:163-70.

24. Sinclair JC. Servo-control for maintaining abdominal skin temperature at 36C in low birth weight infants. Cochrane Database Syst Rev. 2002:CD001074.

25. McCall EM, Alderdice F, Halliday HL, Jenkins JG, Vohra S. Interventions to prevent hypothermia at birth in preterm and/or low birthweight infants. Cochrane Database Syst Rev. 2010:CD004210.

26. Moore ER, Anderson GC, Bergman N, Dowswell T. Early skin-to-skin contact for mothers and their healthy newborn infants. Cochrane Database Syst Rev. 2012;5:CD003519.

27. Perlman JM. Hyperthermia in the delivery: potential impact on neonatal mortality and morbidity. Clinics in perinatology. 2006;33:55-63, vi.

28. Jacobs S, Hunt R, Tarnow-Mordi W, Inder T, Davis P. Cooling for newborns with hypoxic ischaemic encephalopathy. Cochrane Database Syst Rev. 2007:CD003311.

29. Wyllie J, Perlman JM, Kattwinkel J, Atkins DL, Chameides L, Goldsmith JP, Guinsburg R, Hazinski MF, Morley C, Richmond S, Simon WM, Singhal N, Szyld E, Tamura M, Velaphi S. Part 11: Neonatal resuscitation: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Resuscitation. 2010;81 Suppl 1:e260-87.Vain NE, Szyld EG, Prudent LM, Wiswell TE, Aguilar AM, Vivas NI. Oropharyngeal and nasopharyngeal suctioning of meconium-stained neonates before delivery of their shoulders: multicentre, randomised controlled trial. Lancet. 2004;364:597- 602.

30. Wiswell TE, Gannon CM, Jacob J, Goldsmith L, Szyld E, Weiss K, Schutzman D, Cleary GM, Filipov P, Kurlat I, Caballero CL, Abassi S, Sprague D, Oltorf C, Padula M. Delivery room management of the apparently vigorous meconium-stained neonate: results of the multicenter, international collaborative trial. Pediatrics. 2000;105:1-7.

31. Dawson JA, Schmolzer GM, Kamlin CO, Te Pas AB, O'Donnell CP, Donath SM, Davis PG, Morley CJ. Oxygenation with T- piece versus self-inflating bag for ventilation of extremely preterm infants at birth: a randomized controlled trial. The Journal of pediatrics. 2011;158:912-8 e1-2.

32. Poulton DA, Schmolzer GM, Morley CJ, Davis PG. Assessment of chest rise during mask ventilation of preterm infants in the delivery room. Resuscitation. 2011;82:175-9.

33. Perlman JM, Wyllie J, Kattwinkel J, Atkins DL, Chameides L, Goldsmith JP, Guinsburg R, Hazinski MF, Morley C, Richmond S, Simon WM, Singhal N, Szyld E, Tamura M, Velaphi S. Part 11: Neonatal resuscitation: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Circulation. 2010;122:S516-38.

34. Saraswat A, Simionato L, Dawson JA, Thio M, Kamlin CO, Owen L, Schmolzer G, Davis PG. Determining the best method of Nellcor pulse oximeter sensor application in neonates. Acta paediatrica. 2012;101:484-7.

35. Tan A, Schulze A, O'Donnell CP, Davis PG. Air versus oxygen for resuscitation of infants at birth. Cochrane Database Syst Rev. 2005:CD002273.

36. Guay J, Lachapelle J. No evidence for superiority of air or oxygen for neonatal resuscitation: a meta-analysis. Canadian journal of anaesthesia = Journal canadien d'anesthesie. 2011;58:1075-82.

37. Rabi Y, Singhal N, Nettel-Aguirre A. Room-air versus oxygen administration for resuscitation of preterm infants: the ROAR study. Pediatrics. 2011;128:e374-81.

38. Wang CL, Anderson C, Leone TA, Rich W, Govindaswami B, Finer NN. Resuscitation of preterm neonates by using room air or 100% oxygen. Pediatrics. 2008;121:1083-9.

39. Vento M, Moro M, Escrig R, Arruza L, Villar G, Izquierdo I, Roberts LJ, 2nd, Arduini A, Escobar JJ, Sastre J, Asensi MA. Preterm resuscitation with low oxygen causes less oxidative stress, inflammation, and chronic lung disease. Pediatrics. 2009;124:e439-49.

40. Escrig R, Arruza L, Izquierdo I, Villar G, Saenz P, Gimeno A, Moro M, Vento M. Achievement of targeted saturation values in extremely low gestational age neonates resuscitated with low or high oxygen concentrations: a prospective, randomized trial. Pediatrics. 2008;121:875-81.

41. Stenson B, Brocklehurst P, Tarnow-Mordi W. Increased 36-week survival with high oxygen saturation target in extremely preterm infants. The New England journal of medicine. 2011;364:1680-2.

42. Rojas-Reyes MX, Morley CJ, Soll R. Prophylactic versus selective use of surfactant in preventing morbidity and mortality in preterm infants. Cochrane database of systematic reviews. 2012;3:CD000510.

43. Stevens TP, Harrington EW, Blennow M, Soll RF. Early surfactant administration with brief ventilation vs. selective surfactant and continued mechanical ventilation for preterm infants with or at risk for respiratory distress syndrome. Cochrane database of systematic reviews. 2007:CD003063.

44. Yost CC, Soll RF. Early versus delayed selective surfactant treatment for neonatal respiratory distress syndrome. Cochrane database of systematic reviews. 2000:CD001456.

45. Schmolzer GM, Bhatia R, Davis PG, Tingay DG. A comparison of different bedside techniques to determine endotracheal tube position in a neonatal piglet model. Pediatric pulmonology. 2012.

46. Houri PK, Frank LR, Menegazzi JJ, Taylor R. A randomized, controlled trial of two-thumb vs two-finger chest compression in a swine infant model of cardiac arrest [see comment]. Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors. 1997;1:65-7.

47. McGuire W, Fowlie PW. Naloxone for narcotic-exposed newborn infants. Cochrane Database Syst Rev. 2002:CD003483. Moreland TA, Brice JE, Walker CH, Parija AC. Naloxone pharmacokinetics in the newborn. British journal of clinical pharmacology. 1980;9:609-12.

48. Beveridge CJ, Wilkinson AR. Sodium bicarbonate infusion during resuscitation of infants at birth. Cochrane Database Syst Rev. 2006:CD004864.

49. Lokesh L, Kumar P, Murki S, Narang A. A randomized controlled trial of sodium bicarbonate in neonatal resuscitation-effect on immediate outcome. Resuscitation. 2004;60:219-23.

50. Blecic S, De Backer D, Deleuze M, Vachiery JL, Vincent JL. Correction of metabolic acidosis in experimental CPR: a comparative study of sodium bicarbonate, carbicarb, and dextrose. Ann Emerg Med. 1991;20:235-8.

51. Gagnon R, Morin L, Bly S, Butt K, Cargill YM, Denis N, Hietala-Coyle MA, Lim KI, Ouellet A, Raciot MH, Salem S, Hudon L, Basso M, Bos H, Delisle MF, Farine D, Grabowska K, Menticoglou S, Mundle W, Murphy-Kaulbeck L, Pressey T, Roggensack A. Guidelines for the management of vasa previa. Journal of obstetrics and gynaecology Canada : JOGC = Journal d'obstetrique et gynecologie du Canada : JOGC. 2009;31:748-60.

52. Vanhaesebrouck P, Vanneste K, de Praeter C, Van Trappen Y, Thiery M. Tight nuchal cord and neonatal hypovolaemic shock. Archives of disease in childhood. 1987;62:1276-7.

53. Wylie BJ, D'Alton ME. Fetomaternal hemorrhage. Obstetrics and gynecology. 2010;115:1039-51.

54. Cosmi E, Rampon M, Saccardi C, Zanardo V, Litta P. Middle cerebral artery peak systolic velocity in the diagnosis of fetomaternal hemorrhage. International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics. 2012;117:128-30.

55. Slaghekke F, Kist WJ, Oepkes D, Middeldorp JM, Klumper FJ, Vandenbussche FP, Lopriore E. TAPS and TOPS: two distinct forms of feto-fetal transfusion in monochorionic twins. Zeitschrift fur Geburtshilfe und Neonatologie. 2009;213:248-54.

56. Baschat AA, Harman CR. Acute intrapartum twin-to-twin transfusion following successful fetoscopic laser ablation. American journal of perinatology. 2007;24:203-5.

57. Pitaphrom A, Sukcharoen N. Pregnancy outcomes in placental abruption. Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 2006;89:1572-8.

58. Osborn DA, Evans N. Early volume expansion for prevention of morbidity and mortality in very preterm infants. Cochrane Database Syst Rev. 2004:CD002055.

59. Johnson JW, Richards DS. The etiology of fetal acidosis as determined by umbilical cord acid-base studies. American journal of obstetrics and gynecology. 1997;177:274-80; discussion 80-2.

60. Johnson JW, Richards DS, Wagaman RA. The case for routine umbilical blood acid-base studies at delivery. American journal of obstetrics and gynecology. 1990;162:621-5.

61. Lynn A, Beeby P. Cord and placenta arterial gas analysis: the accuracy of delayed sampling. Archives of disease in childhood Fetal and neonatal edition. 2007;92:F281-5.

62. Natarajan G, Shankaran S, Laptook AR et al. Apgar score at 10 minutes and outcomes at 6-7 years following hypoxic ischaemic encephalopathy. Arch Dis Child Fetal Neonatal Ed 2013;98:F473-F479

Revised: January, 2014 Main author: David Osborn