Stringing Equipment and Tools

Total Page:16

File Type:pdf, Size:1020Kb

Stringing Equipment and Tools YEARS experience 55POWERCOM POWERCOM STRINGING EQUIPMENT AND TOOLS STRINGING E QUIPMENT AND TOOLS Powercom sa is one of the most consolidated and renowned companies in the world for stringing equipment and tools manufacturing. It was established in 1891 and it is nowadays located in Switzerland. As global competition increases, manufacturers are faced with constant demands to provide higher quality and better service at lower cost and in less time. Quality, performance and customer oriented attitude are of paramount importance to Powercom sa. Powercom sa is committed to playing a proactive role in today world market by offering its customers better value for money and first class stringing equipment. We are certified ISO 9001. COUNTRIES WHERE POWERCOM EQUIPMENT OPERATES Albania Ecuador Luxembourg Serbia Algeria Egypt Macedonia Sierra Leone Angola El Salvador Malaysia Singapore Argentina Ethiopia Mali Slovenia Australia Fiji Malta South Africa Austria Finland Mauritius Spain Bahrain France Mexico Sri Lanka Bangladesh Germany Moldavia Sweden Belgium Ghana Morocco Switzerland Bolivia Greece Mozambique Syria Bosnia-Hercegovina Guatemala Namibia Taiwan Botswana Honduras Netherlands Tanzania Brazil Hungary New Zealand Thailand Bulgaria Iceland Nigeria Tunisia Cameroon India Norway Turkey Canada Indonesia Oman United Arab Emirates Chile Iran Pakistan United Kindom Cina Iraq Paraguaj United States of Colombia Ireland Peru America (USA) Congo Italy Philippines Uruguay Costa Rica Jordan Poland Venezuela Croatia Kenya Portugal Vietnam Cuba Korea South Qatar Yemen Cyprus Kuwait Romania Zimbabwe Denmark Lebanon Russia Dominican Republic Libya Saudi Arabia POWERCOM POWERCOM www.powercom.ch • e-mail: [email protected] POWERCOM POWERCOM www.powercom.ch • e-mail: [email protected] HYDRAULIC WINCH MODEL PW01.50 Hydraulic winch fit to pull one rope in service operations like setting-ups and adjustments of trasmission lines. One close hydraulic circuit allows to vary continuously the speed in both directions by operating one only control device. • Detachable drum • Automatic swinging rope-winder with idle position for manual operation. • Dinamometer for reading the pull force. • Freewheeling of the drum. • Safety hydraulic negative brake. • Riding axle with tires and drawbar fit for towing at low speed in workplace. • Stabilisers and attacher for anchoring. 005 Preselector of max pull force to stop the engine in case • Heat exchanger to cool the oil in the hydraulic circuit. of overpull. • Rope-driver rollers fit for vertical and horizontal pull. 006 Sevice steel capstans beside the drum. 007 Automatic clamp for rope on side capstan. 008 Steel rope, diam. 8 or 10 mm, length on demand. FEATURES Bottom diameter 200 mm External diameter 500 mm Width 500 mm DRUM CAPACITY Rope Ø 8 mm 800 mm Rope Ø 10 mm 500 mm ENGINE Feeding gasoline Power 8 hp/5,8 kW Cooling air Starting by rope C B A x B x C = 1,20 x 1,15 x 0,85 m A Weight (without rope) = 350 Kg PULL PERFORMANCE ON THE MIDDLE LAYER OF ROPE Max pull 10 kN Speed at max pull 12 m/min. OPTIONAL DEVICES Max speed 40 m/min. 001 Axle with independent torsion bar suspensions and tires Pull at max speed 4 kN towing on the road at 60 Km/h, with mechanical parking on the first layer of rope brake. Max pull 15 kN 002 PVC cloth cover. Speed at max pull 8 m/min. 003 Diesel engine with rope starting. Max speed 30 m/min. 004 Engine electric starting with battery 12V. Pull at max speed 5 kN Model HYDRAULIC WINCH PW01.50 5 POWERCOM POWERCOM www.powercom.ch • e-mail: [email protected] HYDRAULIC WINCH MODEL PW02.30 Hydraulic winch fit to pull one rope in service operations like setting-ups and adjustments of trasmission lines. One close hydraulic circuit allows to vary continuously the speed in both directions by operating one only control device. • Drum equipped with neutral device for unwinding manually the rope while the engne is off. • Automatic swinging rope-winder with idle position for manual operation. • Machine control panel with dynamometer and preselector of max pull force. • Safety hydraulic negative brake. • Riding axle with tires and drawbar fit for towing at low speed in workplace. 007 Service winch with large-groove capstan (Ø 160 or 200 mm) • Stabilisers and attacher for anchoring. fed by the hydraulic circuit of the puller. • Heat exchanger to cool the oil in the hydraulic circuit. Max pulling force 500 kg. • Rope-driver rollers fit for vertical and horizontal pull. 008 Device to control the load descent in case of diesel engine breakdown. 009 Steel rope. FEATURES Drum bottom diameter 270 mm Optional capstan diameter 160 mm DRUM CAPACITY Rope Ø 10 mm - max length 700 mm Rope Ø 10 mm - suggested length 500 mm ENGINE Feeding diesel Power 26 hp/19 kW Cooling water Electric system 12V C B A x B x C = 1,70 x 1,50 x 1,35 m A Weight (without rope) = 850 Kg PULL PERFORMANCE ON THE MIDDLE LAYER OF ROPE Max pull 30 kN OPTIONAL DEVICES Speed at max pull 15 m/min. 001 Amortised axle, overrun brake and drawbar for towing Max speed 70 m/min. on the road (homologation excluded). Pull at max speed 6 kN 002 PVC cloth cover. 003 Metallic coverage with doors. 004 Remote control with 10 meters length cable. 005 Radio control for remote control. 006 Rope-presser roller on the drum. Model HYDRAULIC WINCH PW02.30 6 POWERCOM POWERCOM www.powercom.ch • e-mail: [email protected] HYDRAULIC WINCH MODEL PW03.50 Hydraulic winch fit to pull one rope in service operations like setting-ups and adjustments of trasmission lines. One close hydraulic circuit allows to vary continuously the speed in both directions by operating one only control device. • Steel drum • Automatic swinging rope-winder with idle position for manual operation. • Machine control panel with dynamometer and preselector of max pull force. • Safety hydraulic negative brake. • Riding axle with tires and drawbar fit for towing at low speed in workplace. • Stabilisers and attacher for anchoring. 007 Service winch with large-groove capstan • Heat exchanger to cool the oil in the hydraulic circuit. (Ø 160 or 200 mm) fed by the hydraulic circuit of the puller. • Rope-driver rollers fit for vertical and horizontal pull. Max pulling force 500 kg. 008 Device to control the load descent in case of diesel engine breakdown. 009 Steel rope. FEATURES Drum bottom diameter 400 mm Optional capstan diameter 200 mm DRUM CAPACITY Rope Ø 16 mm 400 mm Rope Ø 14 mm 500 mm ENGINE Feeding diesel Power 47 hp/35 kW Cooling water Electric system 12V C B A x B x C = 2,25 x 1,80 x 1,50 m A Weight (without rope) = 2000 Kg PULL PERFORMANCE ON THE MIDDLE LAYER OF ROPE Max pull 50 kN @ 21m/min. OPTIONAL DEVICES Pull 20 kN @ 60m/min. 001 Amortised axle, overrun brake and drawbar for towing Max speed 65 m/min. on the road (homologation excluded). 002 PVC cloth cover. 003 Metallic coverage with doors. 004 Remote control with 10 meters length cable. 005 Radio control (max distance 50 m). 006 Rope-presser roller on the drum. Model HYDRAULIC WINCH PW03.50 7 POWERCOM POWERCOM www.powercom.ch • e-mail: [email protected] SINGLE AXLE TRAILER FOR CABLE DRUM TRANSPORT MODEL PW04 The trailer is suitable for transporting cable drum, weight max 4200 kg. Lifting drum device by centralized hydraulic plant. Air brake system and lights prescribed, parking brake. Painted steel structure with rear bar. TECHNICAL DATA Lenght drawbar included: 5424 mm Width: 2500 mm Height: 1730 mm Pay load: 4200 kg OPTIONAL Tare: 1200 kg Cable drum winding/unwinding device driven by hydraulic plant Max drum dia: 3000 mm with petrol engine: Max width drum: 1430 mm RUGGERINI 8 HP or BRIGGS & STRATTON 11 HP. Shaft dia: 70 mm Lifting drum: hydraulic device Max towing speed: 80 Km/h. Other capacity and size available on request. Model SINGLE AXLE TRAILER FOR CABLE DRUM TRANSPORT PW04 8 POWERCOM POWERCOM www.powercom.ch • e-mail: [email protected] MODIFIED POLYPROPILENE ROPE MODEL PW08 Wire rope ANTI-TWISTING braided type for stringing conductors operation. CHARACTERISTICS: Thanks to the braided type structure it grants on effective anti-torsional stability during stringing operations. With its special modified polypropylene it grants a strong resisting against abrasion, acid alkali and UV ray. Water repellent. Color: Green. Model Diameter Weight Breaking Standard lengths on mm (gr/m) load 1400 mm diam. PW08.10 10 40 1400 2400 PW08.12 12 60 2300 2000 PW08.14 14 75 2650 1500 PW08.16 16 92 3200 1000 PW08.18 18 110 4050 1000 PW08.20 20 140 5150 1000 NYLON PILOT ROPE FOR STRINGING CONDUCTORS AND CABLES MODEL PW09 Antitwisting braided type polyester pulling rope with internal high tenacity nylon core. Model Diameter Weight Elongation Breaking Standard lengths mm (kg/m) with 35% of load mm Break. load daN PW09.06 8 0,046 5 1200 500-1000-2000 PW09.10 10 0,075 5 2000 1000-1600-2000 PW09.12 12 0,120 5 3500 1000-1600-2000 PW09.14 14 0,160 5 4300 1000-1600-2000 PW09.16 16 0,200 5 5000 1000 PW09.18 18 0,230 5 5800 1000 PW09.20 20 0,280 5 6500 1000 Model MODIFIED POLYPROPILENE ROPE NYLON PILOT ROPE FOR STRINGING PW08 - PW09 CONDUCTORS AND CABLES 9 POWERCOM POWERCOM www.powercom.ch • e-mail: [email protected] ANTITWISTING GALVANIZED SQUARE WIRE ROPE FOR layinG AND STRINGING CONDUCTORS AND CABLES The rope has been designed and developed in order to meet the MODEL PW21 severe workers’ needs while stringing. FEATURES ADVantaGES Several years experience in the field of wire ropes, first class raw PW21 antitwisting galvanized square wire rope offers the following materials, high technology and thanks to skilled labours, PW21 main advantages: model is produced according to the CE and international quality • Perfect non-rotation and safety standards.
Recommended publications
  • TF6 Brochure Large Overhead Line Crossings Feb2009
    396 LARGE OVERHEAD LINE CROSSINGS Working Group B2.08 October 2009 LARGE OVERHEAD LINE CROSSINGS Working Group B2.08 TASK FORCE MEMBERS J.Rogier (BE), K.Van Dam (BE), J.B.G.F. da Silva Convener, (BR), R.C.R. Menezes (BR), A. Fuchs (DE), G. Nesgärd (NO), G. Gheorghita (RO), C. Garcia A. (VE), D. Hughes (GB), L. Kempner (US) Convenor: J.B.G.F. da Silva (Brazil), Secretary: D. Hughes (GB) Regular members: L. Binette (Canada), J. Fernadez (Spain), A. Fuchs (Germany), R. Jansson (Sweden), L. Kempner (United States), D.I. Lee (Korea), N. Masaoka (Japan), G. Nesgard (Norway), V. Numminen (Finland), L. Pellet (France), J. Peralta (Portugal), R.C. Ramos de Menezes (Brazil), J. Rogier (Belgium), J.D. Serrano (R. South Africa), E. Thorsteins (Iceland), S. Villa (Italy), Corresponding members: C.G. Alamo (Venezuela), G. Brown (Australia), G. Gheorghita (Romania), R. Guimarães (Brazil), H Hawes (Australia), C. Laub (Czech Republic), F. Legeron (Canada), T. Leskinen (Finland), M. Ishac (Canada), J.M. Menéndez (Cuba), F. Meza Rosso (Bolivia), K. Nieminen (Finland), R. Peixoto (Brazil), J. Prieto (Spain), C. Thorn (UK), J. Toth (Canada), K. Van Dam (Belgium), M. Vanner (UK) ISBN: 978- 2- 85873- 083-4 Copyright © 2009 “Ownership of a CIGRE publication, whether in paper form or on electronic support only infers right of use for personal purposes. Are prohibited, except if explicitly agreed by CIGRE, total or partial reproduction of the publication for use other than personal and transfer to a third party; hence circulation on any intranet or other company network is forbidden”. Disclaimer notice “CIGRE gives no warranty or assurance about the contents of this publication, nor does it accept any responsibility, as to the accuracy or exhaustiveness of the information.
    [Show full text]
  • State of the Art of Conductor Galloping
    STATE OF THE ART OF CONDUCTOR GALLOPING A complementary document to “Transmission line reference book –Wind-induced conductor motion Chapter 4: Conductor galloping,” Based on EPRI Research project 792 Task Force B2.11.06 Members: Lilien, Jean-Louis - Belgium (Convenor) Van Dyke, Pierre - Canada (Secretary) Asselin, Jean-Marie - Canada Farzaneh, Masoud - Canada Halsan, Kjell - Norway Havard, Dave - Canada Hearnshaw, Dave - England Laneville, André - Canada Mito, Masataka - Japan Rawlins, Charles B. - USA St-Louis, Michel - Canada Sunkle, Dave - USA Vinogradov, Alexandre - Russia International expert who contributed: Yamaguchi, Hiroki - Japan The authors of this brochure have asked detailed comments to: Tunstall, M.J. (former chairman of B2.11.06) - UK Ervik, M. - Norway Obrö, H. - Denmark Okumura, T. - Japan Shkaptsov, V. - Russia FOREWORD TO THE GALLOPING BROCHURE Of all the wind induced motions of Overhead Transmission Line conductors or other suspended cables, galloping is the most noticeable and spectacular and the resulting damage can be equally dramatic and very costly, with broken conductors and fittings, damaged tower components and even whole towers collapsing! The consequential economic and social costs of power loss to whole areas can also be very considerable. Galloping is an oscillation of single or bundled conductors due to wind action on an ice or wet snow accretion on the conductors, although there are recorded instances of non-ice galloping arising from the conductor profile presented to the wind. Conductor motions are characterised by amplitudes that may approach or exceed the conductor sag (possibly >10m) and depending on the amplitudes and number of loops, frequencies up to 3 Hz. Galloping of conductors received particular emphasis by incorporation of a CORECH work group within Task Force 6 (Galloping) of CIGRE SCB2 WG11.
    [Show full text]
  • Design, Supply and Installation of 132Kv & 230Kv Transmission Lines
    POWER GRID COMPANY OF BANGLADESH LIMITED Design, Supply and Installation of 132kV & 230kV Transmission Lines Enhancement of Capacity of Grid Substations and Transmission Lines for Rural Electrification under the Rural Electricity Transmission & Distribution Project of the World Bank VOLUME 2 OF 2 SCOPE OF WORK TECHNICAL SPECIFICATIONS DRAWINGS FORMING PART OF SPECIFICATION January, 2016 POWER GRID COMPANY OF BANGLADESH LIMITED Design, Supply and Installation of 132kV & 230kV Transmission Lines INDEX TO VOLUME 2 OF 2 Section Description Section 1 Scope of Work Section 2 Site Particulars Section 3 Quality Assurance Section 4 Design Particulars Section 5 Access Section 6 Survey and Geotechnical Investigations Section 7 Foundation Section 8 Tower Section 9 Insulator Section 10 Insulator and Conductor Fittings Section 11 Conductor Section 12 Vibration Damper Section 13 Spacer Damper Section 14 Optical Fiber Cable & Fittings Section 15 Aircraft Navigation (Obstruction Aids) Section 16 Miscellaneous Section 17 Packing, Protection and Dispatch Marking Section 18 Method of Measurement & Payment Section 19 Bid Drawings Section 20 Environmental and Social Assessment POWER GRID COMPANY OF BANGLADESH LIMITED Design, Supply and Installation of 132kV & 230kV Transmission Lines INDEX TO VOLUMES Volume 1 of 2 Section 1 - Instruction to Bidders Section 2 - Bid Data Sheet Section 3 - Evaluation and Qualification Criteria Section 4 - Bid Forms Section 5 - Eligible Countries Section 6 - Employer’s Requirements Section 7 - General Conditions of Contract Section
    [Show full text]
  • Towers and Poles Report Ed 6 2018 Electricity, Telephone and Street Lights
    Towers and Poles Report Ed 6 2018 Electricity, Telephone and Street Lights Report Outline Chapter Summaries Table of Contents Sample Tables Sample Pages Edition 6 March 2018 StatPlan Energy Research Towers and Poles Report Ed 6 2018 Chapter Summaries EXECUTIVE SUMMARY PART 1 ELECTRICITY TRANSMISSION TOWERS AND MONOPOLES Chapter 1 - INSTALLED BASE OF ELECTRICITY TRANSMISSON TOWERS & MONOPOLES The global installed base of transmission towers and monopoles is analysed in numbers of towers by region and country and forecast from 2016 to 2020. Chapter 2 - ELECTRICITY TRANSMISSION TOWERS MARKET The global demand in $ value for towers and monopoles is analysed by region and country and forecast from 2016 to 2020. Chapter 3 - LONG TERM DEMAND CYCLES FOR ELECTRICITY TOWERS AND MONOPOLES The growth of transmission line networks is a fundamental driver of the markets for towers and poles, both in line length and voltage. Long term demand is a function of the age of the towers and the expansion of the networks. Chapter 4 - MONOPOLES vs. LATTICE TOWERS The March of the Monopoles - long established in the US, EHV monopoles are breaking into new markets with innovative new designs, replacing lattice towers, especially in Europe. This trend is driven by pressure on rights-of-way, visual criticism of lattice towers and public fears of EMF dangers to children. Chapter 5 - TYPES OF TOWER OR PYLONS Lattice towers are designed for different functions and stresses and there is wide variation in cost; suspension towers, tension towers, angle suspension towers, dead-end towers, transposition towers. Tower installation is a dangerous and complex procedure and has an impact on costs.
    [Show full text]
  • Load Control Devices on Overhead Transmission Lines
    174 LOAD CONTROL DEVICES ON OVERHEAD TRANSMISSION LINES Working Group 22.06 December 2000 LOAD CONTROL DEVICES ON OVERHEAD TRANSMISSION LINES PREPARED BY WORKING GROUP 22.06 Members of the Working Group : Elias GHANNOUM - Convenor (Canada) Joel ANGELINI (France), Jim FERGUSON (United Kingdom), Svein FIKKE (Norway), Edwin GOODWIN (United States), Ramon GRANADINO (Spain), Trevor JACOBS (New Zealand), Friedrich KIESSLING (Germany), Joao Felix NOLASCO (Brazil), Jan ROGIER - New Convenor (Belgium), Pavel FRONEK (Czech Republic). Corresponding Members : D. CHOUDHRY (India), Farid KHADRI (Algeria), Jeong Boo KIM (Korea), Tony PLOG (Netherlands), W. Neil PIERCE (Australia), Helmut STRUB (Switzerland). LOAD CONTROL DEVICES ON OVERHEAD TRANSMISSION LINES Working Group 22.06 TABLE OF CONTENTS 1. SUMMARY 3 2. INTRODUCTION 4 3. CLASSIFICATION OF LCD 5 3.1. Load Release Devices 5 3.2. Load Reduction Devices 5 4. TECHNICAL DATA RELATED TO AVAILABLE LCD 5 4.1. Special Elongated Fittings : Japanese Experience 6 4.1.1. Type I 6 4.1.1.1. Principle 6 4.1.1.2. Design Characteristics 8 4.1.1.3. Mechanical Performance 8 4.1.1.4. Electrical Performance 8 4.1.1.5. Service Experience 8 4.1.2. Type II 9 4.2. Controlled Sliding Clamps 10 4.2.1. French Experience 10 4.2.1.1. Principle of the Controlled Sliding Clamps 10 4.2.1.2. Calibration 11 4.2.1.3. Design of a Controlled Sliding Clamp 12 4.2.1.4. Test 13 4.2.1.5. Device Efficiency 16 4.2.2. Belgian Experience 18 4.2.3. Romanian Experience 18 5.
    [Show full text]
  • Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System Lukasz Skarbek, Arkadiusz Zak, Dominik Ambroziak
    Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System Lukasz Skarbek, Arkadiusz Zak, Dominik Ambroziak To cite this version: Lukasz Skarbek, Arkadiusz Zak, Dominik Ambroziak. Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System. EWSHM - 7th European Workshop on Structural Health Monitoring, IFFSTTAR, Inria, Université de Nantes, Jul 2014, Nantes, France. hal-01020412 HAL Id: hal-01020412 https://hal.inria.fr/hal-01020412 Submitted on 8 Jul 2014 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. 7th European Workshop on Structural Health Monitoring July 8-11, 2014. La Cité, Nantes, France DAMAGE DETECTION STRATEGIES IN STRUCTURAL HEALTH MONITORING OF OVERHEAD POWER TRANSMISSION SYSTEM Lukasz Skarbek1, Arkadiusz Zak1, Dominik Ambroziak1 1 Gdansk University of Technology, Faculty of Electrical and Control Engineering, ul. Wlasna Strzecha 18A, 80-234 Gdansk, Poland [email protected] ABSTRACT Overhead power transmission lines, their supporting towers, insulators and other elements create a highly distributed system that is vulnerable to damage. Typical damage scenarios cover cracking of foundation, breakage of insulators, loosening of rivets, as well as crack- ing and breakage of lines. Such scenarios may result from various factors: groundings, lightning strikes, floods, earthquakes, aeolian vibrations, conductors galloping, icing, and also include sabotage or terrorist attacks.
    [Show full text]
  • Rivne Kyiv High Voltage Line Project [EBRD
    Project „Construction of the 750 kV Rivne NPP – Kyiv overhead transmission line with an extension of the 750 kV Kyiv substation and diversion of the 750 kV overhead transmission line from Khmelnitsk NPP” ENVIRONMENTAL AND SOCIAL IMPACT ASSESSMENT (ESIA)1 May 2007 1 The ESIA has been prepared for meeting environmental requirements of the European Bank for Reconstruction and Development (EBRD) and European Investment Bank (EIB) that are considering the opportunity to finance the Project. The ESIA report is the main document with the help of which the EBRD and EIB will implement environmental assessment of the Project ESIA of Rivne NPP – Kyiv 750 kV transmission line Report prepared by KLC LAW FIRM in consortium with Mott MacDonald, Louis Berger, Kantor Management Consultants Acknowlegements The KLC LAW FIRM consortium would like to acknowledge the contributions of Michael Holgate, Kostas Batos, John Renshaw, Panagiota Maragou, Antony Wheeler, Irina Gallich, Oksana Rakovich, Nataliya Globina, Valentin Dereviankin and Volodymyr Tykhyy in the preparation of this ESIA. Revision Record Rev. Filename Date Reason for issue No Rivne – Kyiv 750 kV ESIA APR16 16 Apr 07 First Draft released to EBRD UKE 750 kV ESIA APR29 29 Apr 07 Update to incorporate EBRD comments UKE 750 kV ESIA ΜΑΥ07 7 May 07 Final Draft - Prior to UKE verification UKE 750 kV ESIA MAY21 21 May 07 Final Draft – Proof-read UKE 750 kV ESIA MAY26 final 28 May 07 Final Draft – Incorporating UKE comments UKE 750 kV ESIA MAY30 Eng 30 May 07 Final Draft released UKE 750 kV ESIA MAY30 Eng i 31-May-07 ESIA of Rivne NPP – Kyiv 750 kV transmission line Contents 1.
    [Show full text]
  • Nepal Electricity Authority 1 TRANSMISSION/PROJECT MANAGEMENT DIRECTORATE
    TRANSMISSION/PROJECT MANAGEMENT DIRECTORATE A Year Book-Fiscal Year 2018/2019 (2075/2076 BS) Nepal Electricity Authority 1 TRANSMISSION/PROJECT MANAGEMENT DIRECTORATE 2 Nepal Electricity Authority A Year Book-Fiscal Year 2018/2019 (2075/2076 BS) TRANSMISSION/PROJECT MANAGEMENT DIRECTORATE Table of Contents Transmission Directorate 7 Recently Completed Projects 7 Grid Development Department 10 Projects under Construction 10 Projects under Planned and Proposed 16 Major 220 kV Transmission Line Department 21 Projects under Construction 21 Projects under Planned and Proposed 24 Major 400 kV Transmission Line Project 26 Projects under Construction 26 Nepal-India Electricity Transmission and Trade Project (NIETTP) 28 Projects under Construction 28 Projects under Planned and Proposed 30 System Operation Department 31 Projects under Construction- LDC Upgradation Project 32 Grid Operation Department 32 Recently Completed Projects 35 Projects under Execution 35 Emergency Restoration Systems (ERS) 36 Administration Division 38 Finance Division 38 Project Management Directorate (PMD) 39 Projects under Construction 40 Projects under Planned and Proposed 44 Summary of under construction/planed & proposed Transmission Lines /Substations 46 Annexure A: List of Figures 47 Annexure B: List of Tables 51 Annexure C: List of Existing Substation-Single Line Diagram (SLD) 67 Maps A Year Book-Fiscal Year 2018/2019 (2075/2076 BS) Nepal Electricity Authority 3 TRANSMISSION/PROJECT MANAGEMENT DIRECTORATE MESSAGE FROM THE MANAGING DIRECTOR t is a moment of great pleasure to know that the Transmission Directorate/Project Management Directorate is bringing Iout the annual publication highlighting various aspects of its activities on the auspicious occasion of Nepal Electricity Authority (NEA)’s 34th anniversary. The role of this directorate is very vital and crucial in terms of the transmission links between generations and distributions as well as load management of the whole power system of Nepal.
    [Show full text]
  • Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System Lukasz Skarbek, Arkadiusz Zak, Dominik Ambroziak
    Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System Lukasz Skarbek, Arkadiusz Zak, Dominik Ambroziak To cite this version: Lukasz Skarbek, Arkadiusz Zak, Dominik Ambroziak. Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System. EWSHM - 7th European Workshop on Structural Health Monitoring, IFFSTTAR, Inria, Université de Nantes, Jul 2014, Nantes, France. hal-01020412 HAL Id: hal-01020412 https://hal.inria.fr/hal-01020412 Submitted on 8 Jul 2014 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. 7th European Workshop on Structural Health Monitoring July 8-11, 2014. La Cité, Nantes, France DAMAGE DETECTION STRATEGIES IN STRUCTURAL HEALTH MONITORING OF OVERHEAD POWER TRANSMISSION SYSTEM Lukasz Skarbek1, Arkadiusz Zak1, Dominik Ambroziak1 1 Gdansk University of Technology, Faculty of Electrical and Control Engineering, ul. Wlasna Strzecha 18A, 80-234 Gdansk, Poland [email protected] ABSTRACT Overhead power transmission lines, their supporting towers, insulators and other elements create a highly distributed system that is vulnerable to damage. Typical damage scenarios cover cracking of foundation, breakage of insulators, loosening of rivets, as well as crack- ing and breakage of lines. Such scenarios may result from various factors: groundings, lightning strikes, floods, earthquakes, aeolian vibrations, conductors galloping, icing, and also include sabotage or terrorist attacks.
    [Show full text]
  • LIFE CYCLE ASSESSMENT for TRANSMISSION TOWERS a Comparative Study of Three Tower Types 20.02.2018
    LIFE CYCLE ASSESSMENT FOR TRANSMISSION TOWERS A comparative study of three tower types 20.02.2018 REPORT – INFORMATION SHEET DOCUMENT SYSTEM CODE REPORT TITLE 3214-095-SKY-001-V01 Life Cycle Assessment for Transmission Towers REPORT NUMBER / TOTAL PAGES PROJECT 01 / 71 KON-002885 PROJECT MANAGER – CLIENT REPRESENT. CLIENT Helge H. Refsum, Marte Bakken Statnett PROJECT MANAGER – EFLA AUTHOR Helga J. Bjarnadóttir Alexandra Kjeld, Gyða M. Ingólfsdóttir, Helga J. Bjarnadóttir, Ragnar Jónsson KEYWORDS EXTRACT Transmission towers, life cycle Statnett is developing prototypes for new types of transmission towers, assessment, carbon footprint, aluminium towers and guyed M-towers. The report identifies environmental impacts environmental impacts of these towers from a life cycle perspective, including a comparison with the current standard steel transmission REPORT STATUS tower. The main findings of the study are that aluminium towers and ☐ Draft guyed M-towers have significantly lower net impacts than standard steel ☐ Copy editing towers in seven environmental impact categories. When impacts are assessed in terms of a 2-km transmission line section, conductors and ☒ Final transmission losses become the largest contributors to environmental REPORT DISTRIBUTION impacts in most categories. ☐ Open The study highlights the importance of sustainable material sourcing for tower manufacturing and the benefits of recycling to minimize negative ☒ With client permission impacts on the environment. The information provided can prove useful ☐ Confidential for strategic decisions at Statnett, e.g. for design and procurement decisions. The study and life cycle inventory provides a basis for further analyses or comparisons. VERSION HISTORY NO. AUTHOR DATE REVIEWED DATE APPROVED DATE 01 Alexandra Kjeld, Gyða 19.12.17 Eva Yngvadóttir 20.12.17 Alexandra Kjeld, Gyða 22.12.17 M.
    [Show full text]
  • Backflashover Analysis for 110-Kv Lines at Multi-Circuit Overhead Line Towers
    Backflashover Analysis for 110-kV Lines at Multi-Circuit Overhead Line Towers M. Kizilcay, C. Neumann Abstract-- An increase of back-flashovers in a 110-kV system model lines, towers, lightning strokes and flashover has been observed along an overhead line route that consists of mechanism over the insulators. Since measurements on real multi-circuit transmission towers of voltage levels 380-kV, 220- towers [1] are costly, various simulation models should be kV and 110-kV at the same tower. The height of multi-circuit compared with each other to validate the simulation results. towers varies in the range of 55 m – 88 m. The 110-kV double- A measure to prevent back-flashovers is to replace one circuit line is positioned at the lowest cross-arm of the tower. insulator string of a duplex line insulator by a surge arrester. Influence of the various factors on the back-flashover of the 110- kV insulator strings has been studied by means of EMTP-ATP The protective level of the surge arrester for lightning strokes simulations. Different current waveforms of the lightning stroke should be selected such that the surge arrester discharges have been used to represent the first stroke and subsequent earlier than the flashover of the insulator. Furthermore, it is strokes. Available flashover analysis methods like leader important to equip a series of towers with surge arresters development method by Pigini et al and by Motoyama, as well as without leaving out a tower in-between. the voltage-time integration method by Kind have been The transients program EMTP-ATP with the integrated implemented using a simulation language and the performance simulation language MODELS is well suited to analyze of flashover models has been compared.
    [Show full text]
  • 750 Kv Zaporizka – Kakhovska Transmission Line and 330 Kv Tl Diversions Project (Zaporizha Oblast, Kherson Oblast)
    750 KV ZAPORIZKA – KAKHOVSKA TRANSMISSION LINE AND 330 KV TL DIVERSIONS PROJECT (ZAPORIZHA OBLAST, KHERSON OBLAST) DRAFT FINAL ESIA REPORT Prepared for: Prepared by: MERCADOS – ENERGY MARKETS INTERNATIONAL Together with: RED ELECTRICA DE ESPAÑA ERM IBERIA ENERGY CONSULTING GROUP July 2009 Project ID: MI 1083 MERCADOS EMI 750 KV ZAPORIZKA – KAKHOVSKA TRANSMISSION LINE AND 330 KV TL DIVERSIONS PROJECT (ZAPORIZHA OBLAST, KHERSON OBLAST) DRAFT FINAL ESIA REPORT CONTENTS Project No. P98267 Ukrenergo TL ZNPP-Kakhovska - Draft Final ESIA Report – July 2009 MERCADOS EMI Contents I INTRODUCTION ............................................................................................... I-1 1.1. BACKGROUND OF ASSIGNMENT ............................................................ I-1 1.2. STRATEGIC REVIEW – PROJECT RATIONALE ........................................... I-2 1.3. PROJECT OWNER .............................................................................. I-5 II PROJECT STATUS AND REGULATORY FRAMEWORK........................................II-1 1. UKRAINIAN REQUIREMENTS.......................................................................... II-1 1.1. GENERAL LEGAL FRAMEWORK.............................................................II-1 1.2. LOCAL ENVIRONMENTAL IMPACT ASSESSMENT .......................................II-3 1.3. PROJECT PERMITTING AND PLANNING PROCESS .....................................II-4 1.4. LAND ASPECTS................................................................................II-7 1.5. HEALTH ASPECTS
    [Show full text]