Quick viewing(Text Mode)

Slurry Handling, Troubleshooting and Filtration

Slurry Handling, Troubleshooting and Filtration

SlurrySlurry Handling,Handling, TroubleshootingTroubleshooting andand FiltrationFiltration

Levitronix CMPUG Symposium Budge Johl – , AZ February 17, 2005 Key CMP Issues & Their Causes

Three key CMP issues encountered in field: High defects/microscatches on wafers Change in polishing performance (removal rate, nonuniformity) Short filter lifetime or reduction in lifetime Associated causes of these three key issues: Large particles in slurry Change in slurry particle size distribution High gel content in slurry Terminology of Particles Observed with SEM, ESEM & Light Microscope

Particle: single solid sphere or other geometry Aggregate: multiple particles chemically attached to each other (chain), primarily via siloxane bonds “Agglomerate”: particles and aggregates come together into close-packed clumps due to entanglement, drying, and coagulation, denser than the surrounding solution Microgels: aggregates link together and form three dimensional network with trapped within; same density and refractive index as the surrounding solution (Filter Plugging Problem)

Particles Aggregate Agglomerate Microgel Ref.: R. Iler, Chapter One , “The of Silica”, John Wiley & Sons, 1979 Potential Defect Causing Agglomerates & Large Particles

Gels

Membrane with Wet Gel & Particles Same Membrane with Dry Gel & Particles

Dry Gels Wet Gels

Large Particles

Silica slurry was diluted with pH adjusted water, then filtered through a 3 micron Isopore membrane. Possible Sources of Large Particles & Gels:

Agglomeration Local drying in shipping container, tank, and fittings Settling pH shock during dilution fluctuation during shipping and storage Shearing (i.e. certain valves, pumps, piping design) Improper Mixing Large # of Turnovers Lack of PM’s on Distribution System Lack of proper slurry conversion protocols from one slurry type to another, including flushing and system sterilization protocols. Oxide Defects “Large Particles” in Slurry Create Micro-Scratches & Embedded Particles on Wafers

Typical defects in oxide CMP Ref.:C. Dennison, KLA-Tencor, Micro, February 1998 W-CMP Defects

Nine types of CMP defects

Ref.: C. Dennison, KLA-Tencor, Micro, February 1998 Large Scratch Cu-CMP Defects Large Chatter Marks Cu-CMP Defects Optical image (Compass®) SEM images (SEMVision™)

AFM (Veeco) Gouge Cu-CMP Defects Optical image (Compass) SEM images (SEMVision)

AFM (Veeco) MicroMicro ScratchScratch Cu-CMP Defects Optical image (Compass) SEM images (SEMVision)

AFM (Veeco) Slurry Troubleshooting Takes Detective Work Slurry Trouble Shooting Methods

Typical Problem Encountered Associated Cause of Problem Troubleshooting Method

Defects including Microscratches Large Particles in Slurry • Particle Counting Eq.

(LPD’s on Wafers) • SEM Analysis • EDX (Elemental Signature)

Change in Polishing Performance Change in Mean Particle Size • Mean Particle Analyzer

Distribution or other parameter • % Solids Measurement • Density

• pH

250 • Conductivity

200 • % Assay 150 • Viscosity 100 • Zeta Potential 50

0 30N50 0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09

Short or Reduced Filter Lifetime Gel Content of Slurry • Delta p measurement

• SEM analysis of used filter •ESEM analysis of slurry Analytical Labs Play Key Role for Slurry Handling, Troubleshooting and

 Total % Solids  Density / Specific Gravity  pH  Conductivity  Viscosity  Mean Particle Size  Large Particle Size  Filtration Testing & Optimization (Source, Post Mix, Global Loop & POU)  Zeta Potential  Percent Assay & Assay Development  Slurry Characterization, Distribution & Handling Evaluations, Slurry Conversion Protocols Drum Contamination

Clean drum surface to remove dust particles before opening When removing lids bung holes should be carefully cleaned before pouring out slurry. Carefully clean the slurry container lids & bung holes before closing left over slurry pails or drums to prevent introducing dry slurry particles. Dip tubes should be clean before introducing into new slurry container. Proper Mixing of Slurry

CUS1201A Mixing Time @ 500 RPM Time (minutes) 0 5 10 15 20 25 29 29.5 30 30.5 31 31.5 Some Mixing 32 32.5 Top Bottom Factors PercentTotal Solids 33  Size of Tote  Age of Slurry Note: Slurry allowed to remain undisturbed for several weeks for Time 0 sample.  Number of Propellers  Type of Mixer and Propeller  Direction of Mixing  RPM  Propeller Scraping Side of Drum Minimizing Particle Growth Humidification Need to humidify the air pockets that come in contact with the slurry with >95% humidity. Need to avoid drying of the slurry which can result in formation of agglomerations and aggregates.

Non-Humidified

Effect of Humidification in CDM’s Effect of CDM’s on Slurry Health

Counts Large Particle Population Distribution

500000

450000

400000 Control

350000 CDM-I

300000

250000 CDM-II

200000

150000 CDM-III

100000

50000

0 0.5 1 1.5 2 2.5 Particle Diameter (µm) -> Levitronix Pump Study

Magnetic Levitation Technology Klebosol® 1501-50

Dynamic Levitronix Pump Study

Storage Tank Turnovers 0 250 500 750 1000 1250 1500 1750 32.5 6

5 30.0 4

Total Percent Solids Viscosity (cP) 27.5 Density (g/mL) 3

2

Total Percent Solids 25.0

1 (g/mL)(cP), Density Viscosity

22.5 0 0 50 100 150 200 250 300 350 Time (Hours) Days 02468101214

0 Klebosol 1501-50

-25

-50

Zeta Potential (mV) Potential Zeta Dynamic Levitronix Pump -75

0 50 100 150 200 250 300 350 HOURS Days 02468101214 150 125 Klebosol 1501-50 100 75 50

Mean PSD(nm) 25 Dynamic Levitronix Pump 0 0 50 100 150 200 250 300 350 HOURS Klebosol 1501-50 Dynamic Levitronix Pump Study 6000

5000 Diameter) 4000 T0hrs T24hrs (122 TO) T144hrs (730 TO) T336hrs (1700 TO)

3000

2000

1000 CumulativeNumber > (# Part

0 0 5 10 15 20 25 30 35 40 45 50 Particle Diameter (microns) Klebosol 1501-50 Dynamic Levitronix Wafer Removal Rate Response

2.0 STANDARD (0 Turnovers) RR LEVITRONIX (1700 Turnovers) RR

1.5

1.0 Normalized RR Data

0.5

0.0 123 Polisher Head # Klebosol 1501-50 Dynamic Levitronix Pump Defectivity Response

4.0

3.5 STANDARD (0 Turnovers)

3.0 LEVITRONIX (1700 Turnovers) 0.1µm ) 2.5

2.0

1.5

1.0 Normalized> Defect Data ( 0.5

0.0 Head 1 Head 2 Head 3 Polisher Head # Filtration

Wonder if this filter will work? Possible Filter Locations

Dilution Day Tank Shipping Cleaning Container Chemical Polishing Filtration DI Tool Filtration Water Track

Post CMP POU Cleaning Filtration Intake Post Recirculated Filtration Dilution Recirculation DI Filtration Loop Filtration Filtration Filter Retention Curves  Filter Ratings Are Not All Created Equal  Filter Retention Curves are Very Useful to Determine Effective Micron Size of the Filter at various Percent Retentions

Retention Efficiency Curves for Planargard CMP Filters

100 CMP1

CMP3 80

CMP5

60 CMP7 CM11

40 CMP9

Percent Retention CM13

20

CM16

0 0 5 10 15 20 25 30 Particle Size (microns) Defectivity Improvement

EPL2362 Defectivity Response

4.0 Dynamic 3 µms Global Loop Filtered m) µ µ µ µ Unfiltered (Static)

0.1 3.5

> Point-of-Use 1.5 µms Filtered (Static) 3.0

2.5

2.0

1.5

1.0

0.5 Normalized Defect Data Respect to Day 0 (

0.0 0 24 72 144 192 Time (Hours)

Large Defectivity Improvement Seen with Global Loop and POU filters. Loop filter : no RR loss

Filter : Mykrolis Corp., Planargard CMP3 10”

If the filter is optimized for the slurry, there is no RR loss. Foreign Materials Found On Filter

Foreign Materials  Can Decrease Filter Life  Such as Plastic Shavings/Misc.  Some Foreign Materials Statically  Attracted to PFA Tubing

 Some Other Possible Sources  Unclean Source Container  Mixing Blade Improperly Adjusted &  Scrapes Side of Drum  Dirty Dip Tubes  Unclean Environment where Drum Opened  Improperly Cleaned Delivery System Filtration Summary

CMP slurry filtration may reduce defects and improve process consistency

POU slurry filtration allows the use of more retentive filters

Higher retention provides better defect reduction

Filtration in slurry delivery systems will extend POU filter’s lifetime

Filter lifetime is highly slurry and process dependent

Lifetime can be monitored by pressure drop and/or flow rate Conclusion

Understanding slurry characteristics, handling properties and filtration is key for maintaining distribution systems, troubleshooting and minimizing large defect causing particles. Rohm and Haas Electronic Materials actively seeks to collaborate with distribution system suppliers, filter companies & others to provide the best solutions for the customer. Together as suppliers we can achieve optimized solutions to fit customer needs and to keep them on target. Acknowledgements

 BOC Edwards and FSI International Publications (John Bare & Budge Johl)

 Mykrolis (Millipore) Ken Adrian, Budge Johl, Geanne Vasilopoulos & Gregg Conner

 Rohm and Haas Electronic Materials (Team)

 Levitronix® – Provided Pump for Evaluation

Compass and SEMVision are trademarks of Applied Materials, Inc. Klebosol is a trademark of AZ Electronic Materials. Planargard is a trademark of Mykrolis Corp.