Problem Set 9 Introduction to Chromatographic Separations 26-1
Total Page:16
File Type:pdf, Size:1020Kb

Load more
Recommended publications
-
Assessment of Energetic Heterogeneity of Reversed-Phase
Seton Hall University eRepository @ Seton Hall Seton Hall University Dissertations and Theses Seton Hall University Dissertations and Theses (ETDs) Spring 5-15-2018 Assessment of Energetic Heterogeneity of Reversed-Phase Surfaces Using Excess Adsorption Isotherms for HPLC Column Characterization Leih-Shan Yeung [email protected] Follow this and additional works at: https://scholarship.shu.edu/dissertations Part of the Analytical Chemistry Commons Recommended Citation Yeung, Leih-Shan, "Assessment of Energetic Heterogeneity of Reversed-Phase Surfaces Using Excess Adsorption Isotherms for HPLC Column Characterization" (2018). Seton Hall University Dissertations and Theses (ETDs). 2527. https://scholarship.shu.edu/dissertations/2527 Assessment of Energetic Heterogeneity of Reversed- Phase Surfaces Using Excess Adsorption Isotherms for HPLC Column Characterization By: Leih-Shan Yeung Dissertation submitted to the Department of Chemistry and Biochemistry of Seton Hall University In partial fulfilment of the requirements for the degree of Doctor of Philosophy In Chemistry May 2018 South Orange, New Jersey © 2018 (Leih Shan Yeung) We certify that we have read this dissertation and that, in our opinion, it is adequate in scientific scope and quality as a dissertation for the degree of Doctor of Philosophy. Approved Research Mentor Nicholas H. Snow, Ph.D. Member of Dissertation Committee Alexander Fadeev, Ph.D. Member of Dissertation Committee Cecilia Marzabadi, Ph.D. Chair, Department of Chemistry and Biochemistry Abstract This research is to explore a more general column categorization method using the test attributes in alignment with the common mobile phase components. As we know, the primary driving force for solute retention on a reversed-phase surface is hydrophobic interaction, thus hydrophobicity of the column will directly affect the analyte retention. -
Synthesis and Applications of Monolithic HPLC Columns
University of Tennessee, Knoxville TRACE: Tennessee Research and Creative Exchange Doctoral Dissertations Graduate School 8-2005 Synthesis and Applications of Monolithic HPLC Columns Chengdu Liang University of Tennessee - Knoxville Follow this and additional works at: https://trace.tennessee.edu/utk_graddiss Part of the Chemistry Commons Recommended Citation Liang, Chengdu, "Synthesis and Applications of Monolithic HPLC Columns. " PhD diss., University of Tennessee, 2005. https://trace.tennessee.edu/utk_graddiss/2233 This Dissertation is brought to you for free and open access by the Graduate School at TRACE: Tennessee Research and Creative Exchange. It has been accepted for inclusion in Doctoral Dissertations by an authorized administrator of TRACE: Tennessee Research and Creative Exchange. For more information, please contact [email protected]. To the Graduate Council: I am submitting herewith a dissertation written by Chengdu Liang entitled "Synthesis and Applications of Monolithic HPLC Columns." I have examined the final electronic copy of this dissertation for form and content and recommend that it be accepted in partial fulfillment of the requirements for the degree of Doctor of Philosophy, with a major in Chemistry. Georges A Guiochon, Major Professor We have read this dissertation and recommend its acceptance: Sheng Dai, Craig E Barnes, Michael J Sepaniak, Bin Hu Accepted for the Council: Carolyn R. Hodges Vice Provost and Dean of the Graduate School (Original signatures are on file with official studentecor r ds.) To the Graduate Council: I am submitting herewith a dissertation written by Chengdu Liang entitled, “Synthesis and applications of monolithic HPLC columns.” I have examined the final electronic copy of this dissertation for form and content and recommend that it be accepted in partial fulfillment of the requirements for the degree of Doctor of Philosophy, with a major in Chemistry. -
Comprehensive Two-Dimensional Liquid Chromatography - Practical Impacts of Theoretical Considerations
Cent. Eur. J. Chem. • 10(3) • 2012 • 844-875 DOI: 10.2478/s11532-012-0036-z Central European Journal of Chemistry Comprehensive Two-Dimensional Liquid Chromatography - practical impacts of theoretical considerations. A review. Review Article Pavel Jandera Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Pardubice 532 10, Czech Republic Received 24 October 2011; Accepted 31 January 2012 Abstract: A theory of comprehensive two-dimensional separations by liquid chromatographic techniques is overviewed. It includes heart-cutting and comprehensive two-dimensional separation modes, with attention to basic concepts of two-dimensional separations: resolution, peak capacity, efficiency, orthogonality and selectivity. Particular attention is paid to the effects of sample structure on the retention and advantages of a multi-dimensional HPLC for separation of complex samples according to structural correlations. Optimization of 2D separation systems, including correct selection of columns, flow-rate, fraction volumes and mobile phase, is discussed. Benefits of simultaneous programmed elution in both dimensions of LCxLC comprehensive separations are shown. Experimental setup, modulation of the fraction collection and transfer from the first to the second dimension, compatibility of mobile phases in comprehensive LCxLC, 2D asymmetry and shifts in retention under changing second-dimension elution conditions, are addressed. Illustrative practical examples of comprehensive LCxLC separations are shown. Keywords: -
Chapter 15 Liquid Chromatography
Chapter 15 Liquid Chromatography Problem 15.1: Albuterol (a drug used to fight asthma) has a lipid:water KOW (see “Profile—Other Applications of Partition Coefficients”) value of 0.019. How many grams of albuterol would remain in the aqueous phase if 0.001 grams of albuterol initially in a 100 mL aqueous solution were allowed to come into equilibrium with 100 mL of octanol? C (aq) ⇌ C (org) Initial (g) 0.001 g 0 Change -y +y Equil 0.001-y y 푦 100 푚퐿 퐾푂푊 = 0.019 = (0.001−푦) ⁄100푚퐿 1.9 x 10-5 – 0.019y = y 1.019y = 1.9 x 10-5 y = 1.864x10-5 g albuterol would be in the octanol layer Problem 15.2: (a) Repeat Problem 15.1, but instead of extracting the albuterol with 100 mL of octanol, extract the albuterol solution five successive times with only 20 mL of octanol per extraction. After each step, use the albuterol remaining in the aqueous phase from the previous step as the starting quantity for the next step. (Note: the total volume of octanol is the same in both extractions). (b) Compare the final concentration of aqueous albuterol to that obtained in Problem 15.1. Discuss how the extraction results changed by conducting five smaller extractions instead of one large one. What is the downside to the multiple smaller volume method in this exercise compared to the single larger volume method in Problem 15.1? 푦 (a) Each step will have this general form of calculation: 퐾 = 20 푚퐿 푂푊 (푔푖푛푖푡−푦) ⁄100푚퐿 (퐾 )(푔 ) so we can calculate the g transferred to octanol from 푦 = 푂푊 푖푛푖푡 5+퐾푂푊 We can use a spreadsheet to calculate the successive steps: First extraction: -
Triple-Detection Size-Exclusion Chromatography of Membrane Proteins
Triple-Detection Size-Exclusion Chromatography of Membrane Proteins vom Fachbereich Biologie der Technischen Universit¨atKaiserslautern zur Erlangung des akademischen Grades Doktor der Naturwissenschaften (Doctor rerum naturalium; Dr. rer. nat.) genehmigte Dissertation von Frau Dipl.-Biophys. Katharina Gimpl Vorsitzende: Prof. Dr. rer. nat. Nicole Frankenberg-Dinkel 1. Gutachter: Prof. Dr. rer. nat. Sandro Keller 2. Gutachter: Prof. Dr. rer. nat. Rolf Diller Wissenschaftliche Aussprache: 08. April 2016 D 386 Abstract Membrane proteins are generally soluble only in the presence of detergent micelles or other membrane-mimetic systems, which renders the determination of the protein's mo- lar mass or oligomeric state difficult. Moreover, the amount of bound detergent varies drastically among different proteins and detergents. However, the type of detergent and its concentration have a great influence on the protein's structure, stability, and func- tionality and the success of structural and functional investigations and crystallographic trials. Size-exclusion chromatography, which is commonly used to determine the molar mass of water-soluble proteins, is not suitable for detergent-solubilised proteins because the protein{detergent complex has a different conformation and, thus, commonly exhibits a different migration behaviour than globular standard proteins. Thus, calibration curves obtained with standard proteins are not useful for membrane-protein analysis. However, the combination of size-exclusion chromatography with ultraviolet absorbance, -
An Introduction to Chromatography
Classification of Chromatographic Methods Classification of Chromatographic Methods (Geometry) •Planar –Paper – Thin layer • Column –GC –HPLC –IC – SFC Classification of Chromatographic Methods (Mobile Phase) • Gas Chromatography • Liquid Chromatography • Supercritical Fluid Chromatography Classification of Chromatographic Methods (Stationary Phase) • Adsorption • Partition • Ion-Exchange • Molecular Exclusion • Affinity Example of Affinity Chromatography Purification of monoclonal antibody on a 5 cm x 4.6 mm column with protein A covalently attached to a polymer support A Hot Idea: Molecular Imprinting An “artificial antibody” can be constructed by synthesizing a polymer in the presence of a template molecule. When the template is removed, the polymer is “imprinted” with the shape of the template and with complementary functional groups that can bind to the template. The imprinted polymer can be used as a stationary phase in affinity chromatography. Molecular Imprinting Hydrophobic Interaction Chromatography (HIC) • Based on the interaction of a hydrophobic stationary phase with a hydrophobic region of a solute such as a protein • A protein can have hydrophilic regions that make it soluble in water and hydrophobic regions interacting with a hydrophobic stationary phase • Proteins are adsorbed on the hydrophobic surface when the aqueous mobile phase contains high salt concentration • Eluent strength is increased by decreasing the salt concentration Hydrophilic Interaction Chromatography (HILIC) • Most useful for small molecules too polar to be retained by reversed-phase HPLC • Stationary phases are strongly polar • The mobile phase contains ≥ 80% polar organic solvent mixed with water Hydrophilic Interaction Chromatography (cont.) • Solute equilibrates between the mobile phase and a layer of aqueous phase on the surface of the stationary phase • Eluent strength is increased by increasing the fraction of water in the mobile phase. -
9.2.3.7 Retention Parameters in Column Chromatography
9.2.3.7 Retention Parameters in Column Chromatography Retention parameters may be measured in terms of chart distances or times, as well as mobile phase volumes; e.g., tR' (time) is analogous to VR' (volume). If recorder speed is constant, the chart distances are directly proportional to the times; similarly if the flow rate is constant, the volumes are directly proportional to the times. Note: In gas chromatography, or in any chromatography where the mobile phase expands in the column, VM, VR and VR' represent volumes under column outlet pressure. If Fc, the carrier gas flow rate at the column outlet and corrected to column temperature (see Flow Rate), is used in calculating the retention volumes from the retention time values, these correspond to volumes at column temperatures. The various conditions under which retention volumes (times) are expressed are indicated by superscripts: thus, a prime ('; as in VR') refers to correction for the hold-up volume (and time) while a circle (º; as in VRº) refers to correction for mobile-phase compression. In the case of the net retention volume (time) both corrections should be applied: however, in order not to confuse the symbol by the use of a double superscript, a new symbol (VN, tN) is used for the net retention volume (time). Hold-up Volume (Time) (VM, tM ) The volume of the mobile phase (or the corresponding time) required to elute a component the concentration of which in the stationary phase is negligible compared to that in the mobile phase. In other words, this component is not retained at all by the stationary phase. -
Studies on the Interaction of Surfactants and Neutral
________________________________________________________ Alma Mater Studiorum – Università di Bologna DOTTORATO DI RICERCA IN SCIENZE FARMACEUTICHE Ciclo XXI Settore scientifico disciplinare di afferenza: CHIM/08 STUDIES ON THE INTERACTION OF SURFACTANTS AND NEUTRAL CYCLODEXTRINS BY CAPILLARY ELECTROPHORESIS. APPLICATION TO CHIRAL ANALYSIS. Dott.ssa Claudia Bendazzoli Coordinatore Dottorato Relatore Prof. Maurizio Recanatini Prof. Roberto Gotti Esame finale anno 2009 ________________________________________________________ “Quando il saggio indica la luna, lo stolto guarda il dito.” (proverbio cinese) ________________________________________________________ To my Mum ________________________________________________________ Table of Contents: Preface (pag.8-9) Chapter 1:Sodium DodecylSulfate and Critical Micelle Concentration • Introduction (pag.11-16) Structure of a Micelle Dynamic properties of surfactants solution • SDS: determination of critical micelle concentration by CE (pag.16-17) • Methodologicalapproaches (pag.18-25) Method based on the retention model—micellar electrokinetic chromatography method Method based on the mobility model—capillary electrophoresis (mobility) method Practical requirements for making critical micelle concentration measurements: micellar electrokinetic chromatography method and capillary electrophoresis (mobility) method • Method based on the measurements of electric current using capillary electrophoresis instrumentation- capillary electrophoresis (current) method (pag.26-28) Practical requirements -
Solubility and Distribution Phenomena Solubility Definitions
Solubility and Distribution Phenomena Solubility definitions • Solubility is: • the concentration of solute in a saturated solution at a certain temperature, • the spontaneous interaction of two or more substances to form a homogeneous molecular dispersion. • Solubility is an intrinsic material property that can be altered only by chemical modification of the molecule. • the solubility of a compound depends on: 1. the physical and chemical properties of the solute and the solvent 2. temperature, pressure, the pH of the solution, • The term miscibility refers to the mutual solubility of the components in liquid–liquid systems. • The equilibrium involves a balance of the energy of three interactions against each other: • (1) solvent with solvent, • (2) solute with solute, • (3) solvent and solute. • Thermodynamic equilibrium is achieved when the overall lowest energy state of the system is achieved. Solubility Expressions • The United States Pharmacopeia (USP): • describes the solubility of drugs as parts of solvent required for one part solute. • Solubility is also quantitatively expressed in terms of molality, molarity, and percentage. • For exact solubilities of many substances: official compendia (e.g., USP) and the Merck Index. Solvent–Solute Interactions • “like dissolves like.” 1. Polar Solvents 2. Nonpolar Solvents 3. Semipolar Solvents Polar Solvents • dissolve ionic solutes and other polar substances. • reduce the attraction between the ions of strong and weak electrolytes because of the solvents' high dielectric constants. • Water dissolves sugars, phenols, alcohols, aldehydes, ketones, amines, and other oxygen- and nitrogen-containing compounds that can form hydrogen bonds with water: • As the length of a nonpolar chain of an aliphatic alcohol increases, the solubility of the compound in water decreases. -
Introduction to High Performance Liquid Chromatography
Introduction to High Performance Liquid Chromatography Klaus Unger, 2007 1 xxCourse Overview • Introduction • Historical perspective • The HPLC system • Separation criteria in HPLC • Separation principles in HPLC • Transport of solutes through the column • Separation principles: selective dilution • Selective retention • Chromatographic parameters for characterizing separations • Elution modes in HPLC • Methodology and instrumentation • Novel developments and approaches 2 Introduction Chromatography – is an analytical technique whereby a sample is separated into its individual components. During separation the sample components are distributed between a stationary phase and a mobile phase. After separation the components can be quantified and even identified. Components Sample Component A C B A Mobile phase Stationary phase Mobile phase Mobile phase 1. Step – Sample is 3. Step – Sample is introduced to stationary flow separated into its phase individual components 2. Step – Sample is separating into its individual components 3 Introduction The major separation modes in chromatography Determined by the nature of mobile phase inert gas liquid supercritical fluid Gas chromatography Liquid chromatography Supercritical fluid chromatography 4 Historical perspective • 1903 Tswett - plant pigments separated on chalk columns • 1931 Lederer & Kuhn - LC of carotenoids • 1938 TLC and ion exchange • 1950 reverse phase LC • 1954 Martin & Synge (Nobel Prize) • 1959 Gel permeation • 1965 instrumental LC (Waters) 5 Historical perspective The term High -
The LC Handbook Guide to LC Columns and Method Development Contents
Agilent CrossLab combines the innovative laboratory services, software, and consumables competencies of Agilent Technologies and provides a direct connection to a global team of scientific and technical experts who deliver vital, actionable insights at every level of the lab environment. Our insights maximize performance, reduce complexity, and drive improved economic, operational, and scientific outcomes. Only Agilent CrossLab offers the unique combination of innovative products and comprehensive solutions to generate immediate results and lasting impact. We partner with our customers to create new opportunities across the lab, around the world, and every step of the way. More information at www.agilent.de/crosslab Learn more The LC Handbook – Guide to LC Columns and Method Development www.agilent.com/chem/lccolumns Buy online www.agilent.com/chem/store Find an Agilent customer center or authorized distributor www.agilent.com/chem/contactus U.S. and Canada 1-800-227-9770 [email protected] Europe [email protected] Asia Pacific [email protected] The LC India [email protected] Handbook Information, descriptions and specifications in this publication are subject to change without notice. Agilent Technologies shall not Guide to LC Columns and be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Method Development © Agilent Technologies, Inc. 2016 Published in USA, February 1, 2016 Publication Number 5990-7595EN -
Equilibrium Study on Interactions Between Proteins and Bile-Salt Micelles by Micellar Electrokinetic Chromatography
ANALYTICAL SCIENCES AUGUST 1996, VOL. 12 569 Equilibrium Study on Interactions between Proteins and Bile-Salt Micelles by Micellar Electrokinetic Chromatography Tohru SAITOH, Teruyuki FUKUDA, Hirofumi TAN!, Tamio KAMIDATE and Hiroto WATANABE Faculty of Engineering, Hokkaido University, Sapporo 060, Japan Interactions between proteins and bile-salt micelles were evaluated on the basis of the binding constants, which were obtained from the migration of proteins in micellar electrokinetic chromatography. The binding constants, Kb-[Pb] J ([PW][B]),where [Pb] is the concentration of a protein binding with a bile-salt, [PW]free protein concentration, and [B] the concentration of bile salt present in the micelles, were successfully determined from the slope of a linear curve of the capacity factor (k') of the protein against [B]. The binding constants were almost identical to those obtained by a gel- filtration method. The value of Kb increased with increasing the hydrophobicity of the bile salt or that of the protein. Keywords Protein, bile-salt micelle, binding constant, micellar electrokinetic chromatography Bile salts have been extensively used in several steps of protein purification, such as the selective solubilization Experimental of membranes, the chromatographic separation of proteins, and the reconstitution of proteins.'-5 A Apparatus predominant factor controlling the separation efficiency An MEKC instrument was made in a manner similar of protein purification is the interactive nature between to that reported by Terabe et al.8-10 The instrument the proteins and the bile-salt micelles. Therefore, a comprised a fused silica capillary tubing with an internal quantitative description of protein-micelle interactions is diameter of 50 µm and a total length of 65 cm; detection necessary for designing micellar-mediated separation was made 50 cm downstream.