Envirograf® Fire and Sound Trap (FST)

Total Page:16

File Type:pdf, Size:1020Kb

Envirograf® Fire and Sound Trap (FST) IS-EAPF-04-12 CI/SFB (68.5) 529F ® ENVIROGRAF Fire seals for Electrical and Plumbers fittings PASSIVE FIRE PROTECTION EXPERTS WIDEST RANGE OF SEALS ON THE MARKET ALMOST 30 YEARS OF EXPERIENCE THE IEE REGULATIONS STATE: "Where cables, conduits, ducts, trunking, or other items of wiring systems pass through walls, floors, roofs, or ceilings of a building, or any part of the hole that is left around the material, shall be made good to the same degree of fire resistance as that required for the element being passed through. Additionally, internal barriers that give the same degree of fire resistance shall be installed in conduits, trunking, ducting, busbars, and busbar trunking, where the walls, floors, ceilings, and roofs have a specified fire resistance." integrity of 90 minutes wide range of collars Intumescent Systems Ltd. Envirograf House, MEMBER Barfrestone, Dover, Kent, CT15 7JG, UK OF THE FIRE +44 (0) 1304 842 555 Fax +44 (0) 1304 842 666 PROTECTION [email protected] | www.envirograf.com ASSOCIATION NEW ELECTRICAL SOCKET FIRE & SOUND TRAP PRODUCT 30 Without Gaskets With Gaskets THE MAIN FEATURES OF THIS VERSATILE PRODUCT ARE: ● IT ONLY TAKES SECONDS TO FIT ● OFFERS BOTH ACOUSTIC AND FIRE PROTECTION ● COMPLIES WITH DOCUMENTS B & E OF CURRENT UK BUILDING REGULATIONS ● TESTED TO PRINCIPLES OF BS EN1366-3, ACHIEVING 2 HOURS FIRE RATING ● TESTED TO BS EN ISO 140 PART 4 WITH A MEAN RESULT 12dB BETTER THAN THE REQUIREMENTS OF DOCUMENT E OF UK BUILDING REGULATIONS Unprotected openings for electrical sockets will reduce the acoustic performance of walls and compromise the resistance to FITTING INSTRUCTIONS fire. To comply with Documents B and E of the current UK Building Regulations, the integrity of the wall must be maintained, and this can be easily achieved with the new Envirograf® Fire and Sound Trap (FST). This versatile product will encase airborne and impact sound and, in the event of a fire, the EXTERNAL FIT INTERNAL FIT product will entrap the flames within the socket box for up to two hours, U FITTING THE INTERNAL ensuring that there is no penetration FIRE & SOUND TRAP of flames and smoke through the The internal FST is simply pushed socket and into the wall cavity. into the box. Peel off the backing This streamlined product, with its paper from the adhesive strips and press firmly to grip the box. The double action design, will help cover plate is fixed to the box in the to save lives and combat both normal way. airborne and impact sound. It is FITTING THE EXTERNAL extremely flexible and it can be U easily fitted in seconds to all types FIRE & SOUND TRAP The external FST is pushed into the of electrical socket boxes, thus aperture whilst maintaining a grip saving valuable installation time. on a flap. Peel off DS tape on the The new Envirograf® Fire and bottom and push the supplied pins Sound Trap (FST) can be fitted onto the plasterboard as shown internally or externally to UPVC above left. Do the same at the top. socket boxes and it has been tested Once fixed cut off surplus material in accordance with the principles of of the flaps as shown on the left. BS EN1366-3, achieving two hours of fire protection. CEILING ROSE FITTINGS 65mm & 75mm diameter Intumescent Cover intumescent gaskets Intumescent cover for Gaskets are placed Without Gaskets With Gaskets Marshall-Tufflex ceiling rose between ceiling rose fitting for plasterboard ceilings fittings and ceiling NEW ACOUSTIC & FIRE PROTECTION FOR METAL SOCKET & SWITCH BOXES PRODUCT 30 Without Gaskets With Gaskets SINGLE BOX SET DOUBLE BOX SET FITTING INSTRUCTIONS An intumescent gasket to adhere inside the metal box. Can have holes 1 2 cut into the gaskets to accommodate tubes and cables. For both single and double boxes, with larger gasket for cooker boxes etc. The gasket has DS tape on the back to adhere to the inside of the metal box. The Insert the metal box into the wall Peel off the protective tape acoustic sponge gasket has corners cut to allow quick & easy application onto the box. 3 4 PERFORMANCE Tested to BS476 Part 22 (1987) and achieved 4 hours in solid walls and 71 minutes in cavity walls. Acoustic Insert the gasket and stick it to Puncture acoustic sponge the metal box to make space for cables protection to Robust Details & 17th Edition IEE Regulations tested in accordance with BS EN 1403 (1995) 5 6 & rated in accordance with BS EN 150 717/1 (1997). Acoustic criteria tested to BS476, Parts 20/22, EN 1364-1 (1999) & EN 1365-2 (1999). Insert the sponge into the box, Installation complete. Your ensuring a tight fit box now has Acoustic & Fire protection BESA BOXES FITINGS Gaskets are simply placed into BESA and knockout boxes H H H H and fixed with the self-adhesive backing tape. Shown here H fitted into PVC or steel INTUMESCENT GASKETS IN ABS conduits. BOXES DOWNLIGHTER ADAPTOR Fire protection & energy efficiency THE NEW ENVIROGRAF® DOWNLIGHTER ADAPTOR, DA1 DA2 Current fire legislation requires ADVANTAGES effective fire safety systems for ● Potential energy saving of up to 40W per unit ceilings and floors in both commercial ● Change to low-energy, long-lasting bulbs with major cost and private buildings. Downlighters, whilst offering an attractive lighting savings solution, can also pose a real danger ● Easy to install adaptor to the fire integrity of a building for two ● Offers up to 66 minutes of fire protection main reasons: ● Can upgrade existing downlighters to use low-energy 1: Holes are cut into the ceiling for bulbs in 9W, 11W, 15W, and 20W ratings and BC or ES type the light units, removing the ceilings holders fire resistance ability and secondly, the units can run at extremely high temperatures presenting the possibility REGULATIONS AND TESTING of ignition, causing a fire. Section B3 in Document B of the UK Building Regulations states the folowing: 2: Energy-saving has also B3 (ii): The resistance of an element of construction is a measure of its become a major priority for building ability to withstand the effects of fire in one or more ways, as follows: owners and occupiers. Downlighters a: resistance to collapse, i.e. the ability to maintain load-bearing capacity can require up to 50W per unit and (which applies to load-bearing elements only); ceilings in many commercial buildings can contain a large number of this b: resistance to fire penetration, i.e. an ability to maintain the integrity of the type of light, resulting in high energy element; and bills. c: resistance to the transfer of excessive heat, i.e. an ability to provide An Envirograf® retro-fitting adaptor insulation from high temperatures. has been developed to convert your Envirograf® Downlighter Adaptors can also assist in meeting the requirements existing downlighter fittings into low- stated in the Approved Document L2B: Conservation of fuel and power energy units, potentially saving up to (Existing buildings other than dwellings). 40W per light, whilst simultaneously Envirograf® Downlighter Adaptors have been tested to BS476 Part 21 providing 66 minutes of fire protection. (1987), achieving 66 minutes of fire protection. FITTING INSTRUCTIONS 1 2 3 Remove the existing downlighter Remove the existing bulb. Clip the Using existing mains wiring, re-wire and disconnect all wiring, including new downlighter adaptor onto the the new adaptor. Two options are any transformer units. back of the downlighter fitting. available for earthing (see ordering references section. DOWNLIGHTER ADAPTOR Fire protection & energy efficiency OFFERING FIRE PROTECTION AND ENERGY EFFICIENCY DESIGN DETAILS The Envirograf® downlighter adaptor is a lightweight metal unit containing intumescent material that expands in a fire, holding the unit in place and sealing the hole in the ceiling structure, thus preventing fire and smoke penetration and maintaining the fire rating of the ceiling/floor. INSTALLATION The Envirograf® downlighter adaptor is simple to fit, only taking a few minutes per unit by a qualified electrician. See the illustrated panel at the DA1 bottom for installation instructions. ORDERING REFERENCES DA1 Earthing to fitting DA2 Bayonet lampholder earthing Add suffix /BC (for bayonet cap fitting) or /ES (for Edison screw fitting) to the reference, according to the type of bulb holder required. DA1 is supplied with a standard white lamp holder with an earthing terminal (marked in the picture above left). DA2 is supplied with a brass lamp holder including earthing terminal (marked in the picture above right). DA2 When ordering, please specify the product name and code of the original light fitting or send us a sample or photograph of the fitting. 4 5 6 Fix the new low-energy bulb into Adjust the fitting to suit the bulb length. Slide the cylinder to the correct length and the fitting in the normal way. fasten the screws to secure. Then fit the lamp unit back into the ceiling. Bulbs are simply changed in the normal way. INTUMESCENT DOWNLIGHTER COVER AND CAGES PRODUCT 32 WITHOUT AN INTUMESCENT COVER, THE LIGHT FITTING WOULD COLLAPSE IN UNDER 4 MINUTES, ALLOWING THE FIRE TO SPREAD TO OTHER PARTS OF THE BUILDING, SIGNIFICANTLY INCREASING THE RISK TO LIFE AND DAMAGE TO PROPERTY, PERHAPS PREVENTING INSURANCE COMPENSATION. Envirograf® DSLV Covers are made to measure for use where transformers or chokes are connected to the light fitting. DESCRIPTION With the increased use of downlighters, the integrity of the plasterboard and suspended ceilings can be reduced to approximately 4 minutes protection. Envirograf® downlighter covers are used to restore the integrity required by British Standards. The covers are available in many standard sizes, and other LIGHT FITTING sizes can be made to order. They are easily installed in about five minutes from below or above the ceiling.
Recommended publications
  • New Microsoft Excel Worksheet (2).Xlsx
    Knowledge Assessment ( Written Test) QP Name - Assistant electrician QP Code:CON/Q0602 Total marks: 210 marks Duration: 90 minutes Each NOS carries 30 marks Infrastructure: Classroom, Benches, Pens, pencils Marks CON/N0602: Select and use hand tools, power tools, and electrical devices relevant to construction electrical works 1 Which device is used to measure current in a circuit? 4 a. Voltmeter b. Ammeter c. Tester d. Megger 4 2 Identify the item form the image below? a. Wattmeter b. Digital Multi meter c. Energy meter d. Analog multi meter 3 Which device is used to avoid overload current in a circuit? 4 a. Residual current circuit breaker b. Miniature circuit breaker c. Earth Leakage circuit breaker d. Molded Case circuit breaker 4 Identify the tool form the image below? 4 a. Channel loch plier b. Combination plier c. Nose plier d. Snippers 5 Which of the following is an ideal instrument used to measure the thickness of conduit? 4 a. Vernier Caliper b. Multi meter c. Measuring tape d. Total station 6 Identify the item form the image below? 5 a. Semi enclosed or re-wire able fuse b. Cartridge type fuse c. D type fuse d. Link type fuse 7 Which of the following tools is used to strip the insulation of cable? 5 a. Plier b. Scissor c. Splicer d. Tester CON/N0603: Install temporary lighting arrangement at construction sites Marks 8 What is the maximum number of 1sq.mm wires that can be drawn through a 25mm diameter conduit 4 a. 5 b. 2 c. 4 d.
    [Show full text]
  • Guideline on Through Penetration Firestopping
    GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING SECOND EDITION – AUGUST 2007 SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 www.smacna.org GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING Copyright © SMACNA 2007 All Rights Reserved by SHEET METAL AND AIR CONDITIONING CONTRACTORS’ NATIONAL ASSOCIATION, INC. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 Printed in the U.S.A. FIRST EDITION – NOVEMBER 1996 SECOND EDITION – AUGUST 2007 Except as allowed in the Notice to Users and in certain licensing contracts, no part of this book may be reproduced, stored in a retrievable system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher. FOREWORD This technical guide was prepared in response to increasing concerns over the requirements for through-penetration firestopping as mandated by codes, specified by system designers, and required by code officials and/or other authorities having jurisdiction. The language in the model codes, the definitions used, and the expectations of local code authorities varies widely among the model codes and has caused confusion in the building construction industry. Contractors are often forced to bear the brunt of inadequate or confusing specifications, misunderstandings of code requirements, and lack of adequate plan review prior to construction. This guide contains descriptions, illustrations, definitions, recommendations on industry practices, designations of responsibility, references to other documents and guidance on plan and specification requirements. It is intended to be a generic educational tool for use by all parties to the construction process. Firestopping Guideline • Second Edition iii FIRE AND SMOKE CONTROL COMMITTEE Phillip E.
    [Show full text]
  • Commercial Conduit Rules and Regulations
    Exhibit C – Commercial Conduit Rules and Regulations Electric Engineering Division COMMERCIAL CONDUIT RULES AND REGULATIONS S:\COO_ACM_US_Electric_Telecommunications\COO_ET_Engineering\Conduit Policies C-1 Exhibit C – Commercial Conduit Rules and Regulations 1805 NE 30th Ave., Bldg. 400 Ocala, FL 34470-4875 Phone: (352) 351-6620 Fax: (352 ) 401-6961 Electric Engineering Division Dear Developer: Over the next few months, the City of Ocala Utility Services (OUS) will be working closely with you and your contractors to install the electrical conduit system for your project. We in the Electric Engineering Division are looking forward to working with your contractors and want the installation to proceed as smooth as possible. Attached, please find the OUS Commercial Conduit Rules and Regulations for use by your electrical conduit contractor. If the contractor has any questions that are not addressed in this guide, please contact the OUS representative responsible for the project. Respectfully Ocala Utility Services Engineering Division C-2 Exhibit C – Commercial Conduit Rules and Regulations TABLE OF CONTENTS i. LETTER TO DEVELOPER ........................................................................................... 2 I. RULES AND REGULATIONS A. TABLE OF CONTENTS ....................................................................................... 3 B. TERMS AND DEFINITIONS ............................................................................... 4 C. DEVELOPER’S RESPONSIBILITIES ...............................................................
    [Show full text]
  • Section 16050 - Basic Electrical Materials and Methods
    Revised 10/03/19 SPECIFICATIONS - DETAILED PROVISIONS Section 16050 - Basic Electrical Materials and Methods C O N T E N T S PART 1 - GENERAL ............................................................................................................................. 1 1.01 SCOPE ........................................................................................................................................ 1 1.02 RELATED SECTIONS ................................................................................................................... 1 1.03 STANDARDS AND CODES ......................................................................................................... 1 1.04 SUBMITTALS ............................................................................................................................. 3 1.05 COORDINATION OF WORK AND TRADES ................................................................................ 4 1.06 DELIVERY, STORAGE, AND HANDLING……………………………………………………………………………….. 5 PART 2 - PRODUCTS .......................................................................................................................... 5 2.01 GENERAL ................................................................................................................................... 5 2.02 CONDUCTORS AND CABLES ..................................................................................................... 6 2.03 CONDUCTOR AND CABLE CONNECTORS ................................................................................
    [Show full text]
  • Specification 270528 Interior Communications Pathways
    GUIDELINES HAS/PDC/Design Division Project Title Houston, Texas Proj./CIP No. (These Guidelines are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer/Contractor/Installation Team.) SECTION 270528 INTERIOR COMMUNICATION PATHWAYS (REV.01-23-2020-SJS) PART 1 GENERAL 1.01 PROJECT SCOPE SUMMARY Designer shall provide a detailed narrative/scope of the tasks to be performed under this specification sections. 1.02 SECTIONS INCLUDES A. This section includes specifications for the installation of interior communications pathways. B. Related Documents: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division - 1 Specification sections, apply to the work of this section. C. Interior Communication Pathways are defined to include, but are not limited to innerduct, flexible multi-cell innerduct, conduit, pull boxes, cable/j-hooks, cable trays, supports, accessories, associated hardware and fire stopping materials. 1.03 REFERENCES A. Related Sections: Use these Specifications for all related work not specifically covered in this specification. 1. Section 270526: Telecommunication Grounding and Bonding 2. Section 270543: Exterior Communication Pathways 3. Section 270553: Identification and Labeling of Communication Infrastructure 4. Section 271100: Communication Cabinets and Equipment Rooms 5. Section 271300: Backbone and Riser Media Infrastructure 6. Section 271500: Horizontal Media Infrastructure 7. Section 272100: Data Communication Network Equipment 8. Section 272200: PC, Laptop, Servers and Equipment 9. Section 275113: Audio Communication System 10. Section 281300: Access Control System 11. Section 232313: Video Surveillance Control and Management System B. American National Standards Institute / Telecommunications Industry Association / Electronic Industries Alliance (ANSI/TIA/EIA): Most current standard revision 1.
    [Show full text]
  • Installation Guide
    Installation Preparation of the hood for installation: To facilitate the installation it is recommended to remove the panel before installing the hood. Attention! Keep both hands on the panel when disassembling or reassembling it into place to prevent it from falling and causing damage to persons or property. Disassembly: - Pull the panel (FRONT SIDE) firmly down, - Push the small lever, located in the right side of the panel, to the left, - Unhook it from the rear joints. 8 Installation - Ducting version 1. Pre-installation calculations 2. Preparation of mounting surface K = Kitchen Height Installing supports above ceiling drywall. C = Counter Height (36" standard) P = Prefered Height of Hood Bottom above counter (Recommended 24”-30”) H = Hood height your installation H = K – C – P a) Select a hood preference height P that is comfortable for the user. (from 24” to 30“). b) Calculate Hood height your installation H = K-C-P. c) Confirm that H is within the range of min to max H found for your model (See “Dimensions and clearances” paragraph). If not adjust your installation. Note: Take into consideration the hood depth; the hood could be much deeper than the cooktop. a. Mark center lines of cooktop or range on ceiling above. Use centerlines marked on ceiling to position the mounting template. Note location of hood front (that indicated with a printed arrow), side, and mounting holes indicated on template. Note: Remember that printed arrow on template corresponds to front of the hood and consequently to side where control panels will be located at the end of installation) b.
    [Show full text]
  • Electrical Conduits
    Electric Level 5 Electrical Conduits What’s it all About? Electrical conduits refer to an electrical system used to protect and provide route of electrical wiring. Electrical conduits are made of metal, plastic, or fiber and could be rigid or flexible. Conduits must be installed by following standard regulations, as those provided by the manufacturer and the National Electrical Code (NEC). Keys to Remember • The 2017 NEC covers 12 types of conduits. Articles 342 through 362 specify use, installation, and construction specifications. • Fill rates, or how many wires can be put in the conduit, is covered in the 2017 NEC Annex C. • Sizing - Conduit tubing uses Outside Dimensions (OD); conduit piping uses Nominal Pipe Size (NPS). Sizes range from 3/8” to 6”. • With any wiring project, safety for people and property is most important. Any metallic conduit should be grounded/bonded to the electrical grounding system. For the Project • Material List with Costs • References • Diagrams • Planning and Research • Dimensions • Title and Labels • Pictures (if exhibiting a report or poster) • Record Sheet Nine Common Types of Electrical Conduit 1. Galvanized Rigid Conduit A conduit made from galvanized steel tubing is commonly referred to as a rigid conduit. The thickness of a galvanized rigid (GR) conduit protects the electrical wiring from being hit and allows it to be threaded. 2. Electrical Metallic Tubing An electrical metallic tubing (EMT) conduit is made of steel; in some cases aluminum is also used. EMT is cheaper than a galvanized rigid conduit and lighter than a GR conduit. EMT is also a very popular material because it can be bent to specific radius and directions.
    [Show full text]
  • Answer the Purpose: 4
    Page 26 1. CONDUCTORS Conductors are defined as materials that easily allow the flow of _________. Metals are _______ conductors while insulators are ______ . The 2 common metals used for conductors in the electrical trade are: ___________ and ______________. Aluminium has become more prevalent for larger C.S.A. conductors as it is cheaper and lighter but more brittle than copper. Current/ Copper/ Aluminium Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth. In mainland Europe, a round equivalent is more common. Flat cables (or festoon cables) are made in PVC and Neoprene and are used as trailing cables for cranes, open filed conveyors and shelve service devices. Flat cables offer the advantages of extremely small bending radius’s, high flexibility and minimum wastage of space. Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth.
    [Show full text]
  • Electric Service Rules
    2021 Electric Service Rules GENERAL INFORMATION TEMPORARY SERVICES OVERHEAD SERVICES UNDERGROUND SERVICES DISTRIBUTED GENERATION METERING HUD MANUFACTURED HOMES FARM SERVICES UTILITY/CATV SERVICES PRIMARY SERVICES SPECIAL SERVICES AND MOTORS OPTIONAL STANDBY GENERATION CLEARANCES GROUNDING AND BONDING ELECTRIC VEHICLES © 2021 Alliant Energy 885247 11/20 AM Version 17 Updates to this manual may be necessary throughout the year. Please see www.alliantenergy.com/servicemanuals for the most up-to-date information. ELECTRIC SERVICE RULES Issued Jan 2021 C a l l B e f o r e Y o u D i g DIGGERS HOTLINE, Telephone Numbers, Alliant Energy Web Site Information & Cable Locating Services ALLIANT ENERGY IP&L/WP&L TELEPHONE NUMBERS Electric Service: 1-800-862-6222 or 1-800-ALLIANT Outage Reporting: 1-877-740-5050 or 1-800-ALLIANT PRE-EXCAVATION TELEPHONE NUMBERS Pre-Excavation Call Number All Areas - 811 Iowa – Iowa One Call: 1-800-292-8989 Wisconsin – Diggers Hotline: 1-800-242-8511 ALLIANT ENERGY WEBSITE Key in Web Site www.alliantenergy.com/servicemanuals C a l l B e f o r e Y o u D i g Page i ELECTRIC SERVICE RULES Issued Jan 2021 TABLE OF CONTENTS - ESR Revision Date: January 2021 CHAPTER 1 – GENERAL INFORMATION...... UPDATED JULY 2021 Page 100. General ...................................................................................................................... 1-1 101. Purpose ..................................................................................................................... 1-1 102. Scope .......................................................................................................................
    [Show full text]
  • Johns Hopkins Enterprise Low Voltage Cabling Standards - Unabridged
    JOHNS HOPKINS INSTITUTIONS Johns Hopkins Enterprise Low Voltage Cabling Standards - Unabridged Approved by the ICSC, Revisions from Standard from 2005 May 2015 JOHNS HOPKINS UNIVERSITY Shelly Hoffmaster, RCDD Johns Hopkins Medicine Network Project Manager Greg Asman, RCDD Network Project Manager IT@JH-Enterprise Networking To: Architects and Consultants Re: Use of Johns Hopkins Cable Plant Design and Construction Specification Date: March 2, 2015 Intended Use This is a general specification for use in developing project construction documents for the information transport systems infrastructure for the Johns Hopkins Institutions. The specification as presented here includes all possible elements for an ITS installation. Designers and Architects will need to select and modify sections of this specification as required for their project. Not all divisions and sections will be applied to every project. Not all paragraphs of any given section may apply to a given project. System variables (e.g. copper pair counts, fiber backbone size) may be displayed as an example within this general specification. When generating a project specification: Designers and Architects will need to submit specifications based on this document to the appropriate Johns Hopkins group for approval of options selected from this specification. Designers and Architects shall not add language to this specification when generating a project- specific specification without approval of Johns Hopkins. When issuing to Contractors for Installation: The Contractor shall be aware of but not focus on the “Design Requirements” section within each specification section used. Contractors are to provide bid proposals per the “Products” sections and install per the “Execution” sections. Errors and omissions within this document shall be reported for correction in the general specification.
    [Show full text]
  • 2017 NATIONAL ELECTRICAL ESTIMATOR by Mark C
    Buy this complete title here: https://goo.gl/JQUG6D $87.75 ® 2017 NATIONAL ELECTRICAL ESTIMATOR By Mark C. Tyler SAMPLE Download all of Craftsman’s most popular costbooks for one low price with the Craftsman Site License. http://CraftsmanSiteLicense.com Turn your estimate into a bid. Turn your bid into a contract. ConstructionContractWriter.com ® Craftsman Book Company 6058 Corte del Cedro, Carlsbad, CA 92011 Buy similar Craftsman Book Co. titles here: https://www.Craftsman-Book.com Buy this complete title here: https://goo.gl/JQUG6D Acknowledgments The author wishes to thank the following individuals and companies for providing materials and information used in this book. George H. Booth, Vice President Sales — Graybar Electric Company, Inc. Steve Koundouriotis — P-W Western, Inc. Don Geibel — Walker Division of Butler Manufacturing Company. The tables on pages 439 and 440 are reprinted with permission from NFPA 70®-2017, the National Electrical Code®, Copyright 2016, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject, which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the National Fire Protection Association, Inc. Quincy, MA 02169. Looking for Other Construction Reference Manuals? Craftsman has the books to ll your needs. Call toll-free 1-800-829-8123 or write to Craftsman Book Company, 6058 Corte del Cedro, Carlsbad, CA 92011 for a FREE CATALOG of over 100 books, including how-to manuals, annual cost books, and estimating software. Visit our Web site: http://www.craftsman-book.com SAMPLE Cover design: Jennifer Johnson ©2016 Craftsman Book Company ISBN 978-1-57218-326-1 Published December 2016 for the year 2017.
    [Show full text]
  • Section 16130 Conduit and Fittings
    Caltrain Standard Specifications SECTION 16130 CONDUIT AND FITTINGS PART 1 – GENERAL 1.01 DESCRIPTION A. Section includes requirements for conduit and conduit fittings. Conduit types shall be as shown on the Contract Drawings and as specified herein. 1.02 REFERENCE STANDARDS A. American National Standards Institute (ANSI): 1. C80.1 Electrical Rigid Steel Conduit (ERCS) B. ASTM International (ASTM): 1. A153 Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware 2. D2564 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems C. American Welding Society (AWS): 1. D1.1 Structural Welding Code - Steel D. California Code of Regulations (CCR): 1. Title 24, Part 3, California Electrical Code E. Institute of Electrical and Electronics Engineers (IEEE): 1. IEEE C2 National Electrical Safety Code (NESC) F. National Electrical Manufacturers Association (NEMA): 1. TC2 Electrical Polyvinyl Chloride (PVC) Conduit 2. TC3 Polyvinyl Chloride (PVC) Fittings for Use with Rigid PVC Conduit and Tubing G. National Fire Protection Association (NFPA): 1. NFPA 70 National Electrical Code (NEC) H. Underwriters Laboratories Inc. (UL): 1. UL 6 Electrical Rigid Metal Conduit - Steel 16130-1 September 30, 2011 CONDUIT AND FITTINGS Caltrain Standard Specifications 2. UL 651 Schedule 40 and 80 Rigid PVC Conduit and Fittings 1.03 DESIGN REQUIREMENTS A. In addition to requirements specified in Section 16000, Basic Electrical Requirements, design supports to support the following loads. 1. Support load equal to sum of weights of conduits and wires, and weight of hanger plus 200 pounds. 2. Stress at root of thread of hanger rods: Not more than 9475 psi at design load.
    [Show full text]