TRIANGLE MICROWORKS, INC. Product Data Sheet

SCADA Data Gateway OPC Client/Server Protocol Translator Data Concentrator

The SCADA Dat a Gat eway (SDG) is a Windows™ application used by System Integrators and Utilities t o collect dat a from, OPC Server, IEC 61850 Server IEC 60870-5, DNP3, or Slave devices and then supplies this data to other control systems supporting OPCClient, IEC 60870-6 (TASE.2/ ICCP) Client, IEC 60870-5, DNP3, and/ or Modbus communication protocols.

PROTOCOLS ▲ OPC Dat a Access Server 1.0a, 2.00, 2.05a, and 3.0 (OPC Cert ified™) ▲ OPC Dat a Access Client 2.00 and 2.05a (OPC Cert ified™) ▲ OPC Alarms and Events 1.00, 1.02, and 1.10 Server (OPC Cert ified™) ▲ OPC Alarms and Events 1.00, 1.02, and 1.10 Client ▲ OPC XML Dat a Access Server ▲ ODBC Client ▲ DNP3 – Serial and TCP/ IP (Conformance t est ed per DNP3 I ntelligent Electronic Device ( I ED) Certification Procedure Subset Level 2, Rev. 2005) ▲ IEC 61850 Client including: 7-410 (Hydro), 7-420 (DER) & 61400-25 (Wind) ▲ IEC 60870-6 (TASE.2/ ICCP) Server ▲ IEC 60870-5-101 – Basic Telecont rol Tasks ▲ IEC 60870-5-103 – Protection Equipment ▲ IEC 60870-5-104 – Network access for -101 ▲ Modbus Serial ASCII/ RTU, Modbus Plus, and Modbus TCP ▲ Translat e t o ot her prot ocols such as SNMP by combining the SDG with another OPC Client/ Server SCADA Data Gateway Typical Uses and Example Features

Diagnostics Display. Built-in diagnostics includes status information and error counts that are Typical Uses of the SCADA Data Gateway exposed through OPC and can be mapped to a status point in other protocols. Separate diagnostics Channel are available for the entire SDG and for each channel, session, and sector. Display. The SDG supports DNP3 OPC Server multiple channels, utilizing Connect your PC-based SCADA system to a Modbus the same or remote device using any combination of the different following protocols IEC 60870-5-101 protocols. Mixed channel types (serial,

OPC IEC 60870-5-103 TCP/IP, modem) and Multidrop connections are IEC 60870-5-104 supported. SCADA HMI Client SDG Use any OPC Client to build your HMI. IEC 61850 OPC Alarm & Events can be used to Scaling allows conversion of raw data to guarantee delivery of all event data and engineering units. Mapping Information Display. All points are automatically mapped to the SDG’s OPC Server. Other provide a more accurate timestamp. mappings are assigned using simple drag and drop operations. Points may be mapped from Master to Slave, Master to Master, or Slave to Slave components.

Protocol Translator DNP3

Modbus DNP3 Modbus Current value and quality status display. Displays current value, quality status, reported time, and data type. IEC 60870-5-101 IEC 60870-5-101

IEC 60870-5-103

IEC 60870-5-104 IEC 60870-5-103

IEC 60870-5-104

Master Station SDG IEC 61850 Translate between any number of these protocols. The SDG’s OPC Client can be used to rd 3rd Party OPC Server & Equation editor supports creation of new data translate between any protocol supported by a 3 RTU with Proprietary Protocol party OPC Server and the industry standard points based on raw data or even combinations protocols shown. For example, managing of raw data points and/or other equation points. networks via SNMP is achieved using an SNMP- to-OPC Client. Protocol analyzer display displays and decodes each Tag Selector facilitates mapping between message Multiple Window Support. Simplifies drag and drop operations, such as mapping points between protocols, Master Data Objects, permitting two Slave  Filters allow display of as shown above, or viewing a separate protocol analyzer trace for each device, as shown below. devices to communicate through the SDG. only desired level of information.  Display any selected channels, sessions, or sectors  Scroll back buffer allows copying to the Windows™ clipboard and examination of previous messages  Search function allows finding a specific protocol Internal Tags can be created and mapped. exchange quickly Internal tags can be used to provide output  Protocol analyzer log can control through the SDG, or to map external be saved as a text file for Master devices together. later analysis  SCADA Data Gateway Product Data Sheet

Triangle MicroWorks is an act ive member in t he IEC Technical Committee 57 Workgroup 03, UCA International Users Group, t he OPC Foundat ion, t he DNP3 Users Group (serving on both the Technical and Executive Committees), and the Modbus Organization. We are also proud to sponsor t he IEC 60870-5 Maillist and maintain the associated website. Our communication protocol expertise will provide you with the highest quality software and technical support possible.

FEATURES

▲ OPC Cert ified™; Conformance t est ed per DNP3 I ntelligent Electronic Device ( I ED) Certification Procedure Subset Level 2,Rev. 2005) ▲ Report by Exception (RBE) is supported (transmitting only data changes, saving communication channel bandwidth). ▲ Supports selective logging of event data into a time-st amped Sequence of Event s (SOE) log file. ▲ The Communication Protocol Analyzer Window displays and decodes t ransmit t ed and received messages. ▲ Allows translation between data types and control methods from different protocols. Supports mapping of points bet ween Mast er and Slave, t wo Mast er, and/ or t wo Slave protocol components.

HARDWARE

The SDG uses st andard serial communicat ion port s or Ethernet ports on a PC running Windows 7, Windows Vista, Windows XP SP2, Windows 2008 Server, Windows 2003 Server, or Windows XP Embedded. Typical Windows-based programs compatible with the SDG include: Iconics GENESIS64™/ GENESIS32™, GE Proficy HMI/ SCADA iFI X™ and CIMPLI CITY™, Wonderware® InTouch HMI, Siemens SIMATI WinCC, Microsoft® ™, or any other program which is capable of act ing as an OPC Client / Server. PRI CING

Each license is t ied t o a single PC or removable USB Flash Drive (see USB License opt ion below).

Master/Client Slave/Server Base SCADA Data Gateway: 400 Point Count no charge Unlimited Point Count $1,000 USB License (does not include a Flash Drive) $500 Protocol Components (Select 2 or More): DNP3 $500 $500 IEC 60870-5-101 $500 $500 IEC 60870-5-102 n/a n/a IEC 60870-5-103 $500 n/a IEC 60870-5-104 $500 $500 OPC Data Access $500 $500 OPC XML Data Access n/a $500 OPC Alarm & Event $500 $500 IEC 61850 including: 7-410 (Hydro), 7-420 (DER) & 61400-25 (Wind) $2500 n/a IEC 60870-6 (TASE.2/ICCP) n/a $2500 Modbus $500 $500 ODBC $500 n/a

SUPPORT AND UPGRADES

The Maint enance & Enhancement Plan provides a cost effective method for upgrading to new versions of t he SDG as t hey are released. It also provides technical support by telephone, fax, or email. The first year of the Maintenance & Enhancement Plan is free. Fut ure years may be purchased in advance at a 25% discount . The renewal price aft er t he first year is 25% of the total purchase price. For example, the Maintenance Plan for the 400 point count SDG with two protocol components (i.e., OPC Server & IEC 6070-5-101 Master) would be $250 USD per year.

™Windows is a Registered Trademark of Microsoft Corporation Revised 06/2011