Automatic Flue Damper the Perfect Solution for Open Hearth Gas Fireplaces

Total Page:16

File Type:pdf, Size:1020Kb

Automatic Flue Damper the Perfect Solution for Open Hearth Gas Fireplaces Automatic Flue Damper The perfect solution for open hearth gas fireplaces. Flue Sentinel Top off chimney Stop heat loss Save up to 30% For a beautiful, open hearth gas fireplace, you need a Flue Sentinel. It’s an electronic damper that automatically opens when you turn on your gas logs and closes when you turn them off. It’s installed at the top of your chimney so you never see or hear it operate but you will immediately notice the difference. No more cold Features drafts coming down the chimney and no more heated • The first electronic flue damper for gas air escaping from the chimney. The Flue Sentinel can log fireplaces save as much as 30% on your energy bill, paying for • For hearths up to 6' wide itself in no time. • For flue diameters 8" to 24" • Meets new fireplace codes The invisible solution for • Square/Rectangular models available the modern fireplace. The desire: Benefits A large, open gas fireplace. • Seals chimney and eliminates cold drafts. The problem: • Eliminates the need for glass doors to conserve Heat loss. Cold, drafty rooms. Wasted energy. heat. Creates an instant “wow” factor with a The old solution: large, open hearth. A manual damper, permanent glass panes, or glass doors. • Ultimate convenience. You never have to The new solution: remember to close your flue again. The Flue Sentinel mounts on top of the • Traps heat inside the chimney. chimney, opens and closes automatically, and saves energy. Fireplace Options Option Result Direct Vent Gas Interferes with hearth and building design Ventless Gas Limited to small fireplaces Wood Messy, expensive, and restricted in many areas Glass doors/Enclosures Limits view, heat, and size of hearth Open Hearth Gas Logs with Flue Sentinel Safe, quiet, natural venting that conserves energy. Natural look and feel. Chimney Top Automatic Flue Damper Models We offer four basic models with sizes to fit chimney diameters from 8" to 24" with low profile options that are only six inches tall. The Flue Sentinel can be installed in new or pre-existing chimneys. Each unit is constructed of high grade stainless steel and comes with a two year manufacturer's warranty. FSE 24 Volt Round For 24 VAC, 60 Hz intermittent ignition and standing pilot ignition systems for gas log fireplaces. FSE 24V Round FSM Millivolt Round Designed to operate with millivolt/standing pilot ignition systems for gas log fireplaces. FSE/FSM Low Profiles Units are 6" in height and require a vent cap. Rectangular/Square FSM Millivolt Round Custom units and adapter kits can be special ordered for any chimney top. FSE/FSM Low Profile Accessories Electronic Ignition Kit Combustion Air Unit Simplifies 24 VAC installation. Electronically opens and closes as needed to Includes: provide additional air for combustion. • Honeywell Intermittent Pilot Retrofit Kit • Galvanized steel construction. • Honeywell Target Type Pilot Burner Paintable. • Transformer: 24volt 40va Class 2 • Automatic operation. • 1/4" pilot gas line - 3 feet • Two models - 4" & 6" • 2" x 4" x 2" Electrical Junction Box • 12" x 12" x 6" Gang Box - UL Listed High Temp Wiring Harness Chimney Pipe Adapter Kits Simplifies retrofit installation. Harness can be We provide adapter kits to connect the installed in the flue for direct connection to Flue Sentinel to air cooled chimney the gas valve. pipe. Our kits connect all major • UL rated for continuous temps brands of pipe with O.D.s ranging to 1000º F from 8" up to 16". • Works with 24 volt and millivolt systems • Available in lengths 25'-60' FSE Series FSE Series Voltage Frequency Current Maximum Current Operating Temperature Timing Controller: -40˚-140˚F 7 seconds to open 50/60 Hz 80 mA 5 A A 24 VAC Pipe: -40˚-650˚F 30-40 seconds to close Model A B C D Weight (lbs.) B FSE-8 7.8 10.5 17.0 13.8 7.8 FSE-10 9.8 10.5 19.0 15.8 8.9 FSE-11 10.8 10.5 20.0 16.8 9.4 FSE-12 11.8 10.5 21.0 17.8 10.0 D FSE-13 12.8 12.5 22.0 18.8 11.3 FSE-14 13.8 12.5 23.0 19.8 12.0 FSE-16 15.8 12.5 25.0 21.8 13.3 C FSE-18 17.8 13.5 27.0 23.8 15.6 FSE-20 19.8 14.5 29.0 25.8 17.8 FSE-22 21.8 15.5 31.0 27.8 20.1 FSE-24 23.8 16.5 33.0 29.8 22.9 FSM Series FSM Series Controller Voltage Switching Voltage Battery Life Operating Temperature Timing Controller: -40˚-140˚F 7 seconds to open A 100-750 mVDC 10 years 3.6 VDC Pipe: -40˚-650˚F 30-40 seconds to close Model A B C D Weight (lbs.) B FSM-8 7.9 10.5 17.8 13.8 7.8 FSM-10 9.9 10.5 19.8 15.8 8.9 C FSM-11 10.9 10.5 20.8 16.8 9.4 FSM-12 11.9 10.5 21.8 17.8 10.0 FSM-13 12.9 12.5 22.8 18.8 11.3 FSM-14 13.9 12.5 23.8 19.8 12.0 FSM-16 15.9 12.5 25.8 21.8 13.3 FSM-18 17.9 13.5 27.8 23.8 15.6 FSM-20 19.9 14.5 29.8 25.8 17.8 D FSM-22 21.9 15.5 31.8 27.8 20.1 FSM-24 23.9 16.5 33.8 29.8 22.9 FSE Low Profile & FSM Low Profile - Vent Cap Required Low Profile Model A B C D Weight (lbs.) Clearance (in.) A FSE-L6/ FSM-L6 5.9 6.0 14.5 11.8 4.02 .25 FSE-L8/ FSM-L8 7.9 6.0 16.5 13.8 4.25 1.25 B FSE-L10/ FSM-L10 9.9 6.0 18.5 15.8 5.25 2.25 FSE-L11/ FSM-L11 10.9 6.0 19.5 16.8 5.81 2.75 FSE-L12/ FSM-L12 11.9 6.0 21.5 17.8 6.36 3.25 D FSE-L13/ FSM-L13 12.9 6.0 22.5 18.8 6.55 3.75 FSE-L14/ FSM-L14 13.9 6.0 23.5 19.8 7.07 4.25 FSE-L16/ FSM-L16 15.9 6.0 25.5 21.8 8.25 5.25 FSE-L18/ FSM-L18 17.9 6.0 27.5 23.8 9.80 6.25 FSE-L20/ FSM-L20 19.9 6.0 29.5 25.8 11.25 7.25 FSE-L22/ FSM-L22 21.9 6.0 31.5 27.8 12.35 8.25 C FSE-L24/ FSM-L24 23.9 6.0 33.5 29.8 13.75 9.25 fieldcontrols.com Field Controls, LLC 2630 Airport Road Kinston, NC 28504 t: 252.522.3031 f: 252.522.0214 ©2013 Field Controls Form # 4356 Printed in U.S.A.(RS13).
Recommended publications
  • Heat Generation Technology Landscaping Study, Scotland's
    Heat Generation Technology Landscaping Study, Scotland’s Energy Efficiency Programme (SEEP) BRE August 2017 Summary This landscaping study has reviewed the status and suitability of a number of near-term heat generation technologies that are not already significantly established in the market-place. The study has been conducted to inform Scottish Government on the status and the technologies so that they can make informed decisions on the potential suitability of the technologies for inclusion within Scotland’s Energy Efficiency Programme (SEEP). Some key findings which have emerged from the research include: • High temperature, hybrid and gas driven heat pumps all have the potential to increase the uptake of low carbon heating solutions in the UK in the short to medium term. • High temperature heat pumps are particularly suited for off-gas grid retrofit projects, whereas hybrids and gas driven products are suited to on-gas grid properties. They may all be used with no or limited upgrades to existing heating systems, and each offers some advantages (but also some disadvantages) compared with standard electric heat pumps. • District heating may continue to have a significant role to play – albeit more on 3rd and 4th generation systems than the large high temperature systems typical in other parts of Europe in the 1950s and 60s – due to lower heating requirements of modern retrofitted buildings. • Longer term, the development of low carbon heating fuel markets may also present significant opportunity e.g. biogas, and possibly hydrogen.
    [Show full text]
  • 5Th-Generation Thermox WDG Flue Gas Combustion Analyzer
    CONTROL EXCLUSIVE 5th-Generation Thermox WDG Flue Gas Combustion Analyzer “For more than 40 years, we have been a leader in combustion gas analysis,” says Mike Fuller, divison VP of sales and marketing and business development for Ametek Process Instruments, “and we believe the WDG-V is the combustion analyzer of the future.” WDG analyzers are based on a zirconium oxide cell that provides a reliable and cost-effective solution for measuring excess oxygen in flue gas as well as CO and methane levels. This information allows operators to obtain the highest fuel effi- ciency, while lowering emissions for NOx, CO and CO2. The zir- conium oxide cell responds to the difference between the concen- tration of oxygen in the flue gas versus an air reference. To assure complete combustion, the flue gas should contain several percent oxygen. The optimum excess oxygen concentration is dependent on the fuel type (natural gas, hydrocarbon liquids and coal). The WDG-V mounts directly to the process flange, and is heated to maintain all sample-wetted components above the acid dewpoint. Its air-operated aspirator draws a sample into the ana- lyzer and returns it to the process. A portion of the sample rises into the convection loop past the combustibles and oxygen cells, Ametek’s WDG-V flue gas combustion analyzer meets SIL-2 and then back into the process. standards for safety instrumented systems. This design gives a very fast response and is perfect for process heat- ers. It features a reduced-drift, hot-wire catalytic detector that is resis- analyzer with analog/HART, discrete and Modbus RS-485 bi-direc- tant to sulfur dioxide (SO ) degradation, and the instrument is suitable 2 tional communications, or supplied in a typical “sensor/controller” for process streams up to 3200 ºF (1760 ºC).
    [Show full text]
  • Humidity in Gas-Fired Kilns Proportion of Excess Combustion
    HUMIDITY OF COMBUSTION PRODUCTS FROM WOOD AND GASEOUS FUELS George Bramhall Western Forest Products Laboratory Vancouver, British Columbia The capital and operating costs of steam kilns and the boilers necessary for their operation are so high-in Canada that they are not economically feasible for small operations drying softwoods. About thirty years ago, direct fired or hot-air kilns were intro- duced. In such kilns natural gas, propane, butane or oil is burned and the combustion products conducted directly into the drying chamber. This design eliminates the high capital and operating costs of the steam boiler, and permits the small operator to dry lumber economically. However, such kilns are not as versatile as steam kilns. While they permit good temperature control, their humidity control is limited: they can only reduce excess humidity by venting, they cannot increase it and therefore cannot relieve drying stresses at the end of drying. For this reason, they are usually limited to the drying of structural lumber. Due to the decreasing supplies and increasing costs of fossil fuels, there is growing interest in burning wood residues to pro- vide the heat for drying. Although wood residue was often the fuel for steam boilers, the capital and operating costs of boilers are no more acceptable now to the smaller operator than they were a few years ago. The present trend is rather to burn wood cleanly and conduct the combustion products into the kiln in the same man- ner as is done with gaseous fossil fuels. This is now being done successfully with at least one type of burner, and others are in the pilot stage.
    [Show full text]
  • Theoretical Study of the Flow in a Fluid Damper Containing High Viscosity
    Theoretical study of the flow in a fluid damper containing high viscosity silicone oil: effects of shear-thinning and viscoelasticity Alexandros Syrakosa,∗, Yannis Dimakopoulosa, John Tsamopoulosa aLaboratory of Fluid Mechanics and Rheology, Department of Chemical Engineering, University of Patras, 26500 Patras, Greece Abstract The flow inside a fluid damper where a piston reciprocates sinusoidally inside an outer casing containing high-viscosity silicone oil is simulated using a Finite Volume method, at various excitation frequencies. The oil is modelled by the Carreau-Yasuda (CY) and Phan-Thien & Tanner (PTT) constitutive equations. Both models account for shear-thinning but only the PTT model accounts for elasticity. The CY and other gener- alised Newtonian models have been previously used in theoretical studies of fluid dampers, but the present study is the first to perform full two-dimensional (axisymmetric) simulations employing a viscoelastic con- stitutive equation. It is found that the CY and PTT predictions are similar when the excitation frequency is low, but at medium and higher frequencies the CY model fails to describe important phenomena that are predicted by the PTT model and observed in experimental studies found in the literature, such as the hysteresis of the force-displacement and force-velocity loops. Elastic effects are quantified by applying a decomposition of the damper force into elastic and viscous components, inspired from LAOS (Large Am- plitude Oscillatory Shear) theory. The CY model also overestimates the damper force relative to the PTT, because it underpredicts the flow development length inside the piston-cylinder gap. It is thus concluded that (a) fluid elasticity must be accounted for and (b) theoretical approaches that rely on the assumption of one-dimensional flow in the piston-cylinder gap are of limited accuracy, even if they account for fluid viscoelasticity.
    [Show full text]
  • Geometry of Thermodynamic Processes
    Article Geometry of Thermodynamic Processes Arjan van der Schaft 1, and Bernhard Maschke 2 1 Bernoulli Institute for Mathematics, Computer Science and Artificial Intelligence, Jan C. Willems Center for Systems and Control, University of Groningen, the Netherlands; [email protected] 2 Univ. Lyon 1, Université Claude Bernard Lyon 1, CNRS, LAGEP UMR 5007, Villeurbanne, France; [email protected] * Correspondence: [email protected]; Tel.: +31-50-3633731 Received: date; Accepted: date; Published: date Abstract: Since the 1970s contact geometry has been recognized as an appropriate framework for the geometric formulation of the state properties of thermodynamic systems, without, however, addressing the formulation of non-equilibrium thermodynamic processes. In [3] it was shown how the symplectization of contact manifolds provides a new vantage point; enabling, among others, to switch between the energy and entropy representations of a thermodynamic system. In the present paper this is continued towards the global geometric definition of a degenerate Riemannian metric on the homogeneous Lagrangian submanifold describing the state properties, which is overarching the locally defined metrics of Weinhold and Ruppeiner. Next, a geometric formulation is given of non-equilibrium thermodynamic processes, in terms of Hamiltonian dynamics defined by Hamiltonian functions that are homogeneous of degree one in the co-extensive variables and zero on the homogeneous Lagrangian submanifold. The correspondence between objects in contact geometry and their homogeneous counterparts in symplectic geometry, as already largely present in the literature [2,18], appears to be elegant and effective. This culminates in the definition of port-thermodynamic systems, and the formulation of interconnection ports.
    [Show full text]
  • Air Separation, Flue Gas Compression and Purification Units for Oxy-Coal Combustion Systems
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Elsevier - Publisher Connector Energy Energy Procedia 4 (2011) 966–971 www.elsevier.com/locate/procediaProcedia Energy Procedia 00 (2010) 000–000 www.elsevier.com/locate/XXX GHGT-10 Air Separation, flue gas compression and purification units for oxy-coal combustion systems Jean-Pierre Traniera, Richard Dubettierb, Arthur Dardeb, Nicolas Perrinc aAir Liquide SA-Centre de Recherche Claude Delorme,Chemin de la porte des Loges, Les Loges en Josas, Jouy en Josas F-78354, France bAir Liquide Engineering, 57 Ave. Carnot BP 313,Champigny-sur-Marne F-94503, France cAir Liquide SA, 57 Ave. Carnot BP 313, Champigny-sur-Marne F-94503, France Elsevier use only: Received date here; revised date here; accepted date here Abstract Air Liquide (AL) has been actively involved in the development of oxy-coal technologies for CO2 capture from power plants for almost 10 years. Large systems for oxygen production and flue gas purification are required for this technology. Air Liquide has been a leader in building large Air Separation Units (ASUs) and more developments have been performed to customize the air separation process for coal-fired power plants. Air Liquide is also actively involved in developing processes for purification of flue gas from oxy-coal combustion systems for enhanced oil recovery applications as well as sequestration in saline aquifers. Through optimization of the overall oxy-coal combustion system, it has been possible to identify key advantages of this solution: minimal efficiency loss associated with CO2 capture (less than 6 pts penalty on HHV efficiency compared to no capture), near zero emission, energy storage, high CO2 purity and high CO2 recovery capability.
    [Show full text]
  • 179 Design of a Hydraulic Damper for Heavy Machinery
    ANALELE UNIVERSIT ĂłII “EFTIMIE MURGU” RE ŞIłA ANUL XVIII, NR. 1, 2011, ISSN 1453 - 7397 Emil Zaev, Gerhard Rath, Hubert Kargl Design of a Hydraulic Damper for Heavy Machinery A hydraulic unit consisting of an accumulator as energy storage element and an orifice providing friction was designed to damp oscillations of a machine during operation. In the first step, a model for the gas spring was developed from the ideal gas laws for the dimensioning the elements. To model the gas process with a graphical simulation tool it is necessary to find a form of the gas law which can be integrated with a numerical solver, such as Tustin, Runge-Kutta, or other. For simulating the working condition, the model was refined using the van der Waals equations for real gas. A unified model representation was found to be applied for any arbitrary state change. Verifications were made with the help of special state changes, adiabatic and isothermal. After determining the dimensional parameters, which are the accumulator capacity and the orifice size, the operational and the limiting parameters were to be found. The working process of a damper includes the gas pre-charging to a predefined pressure, the nearly isothermal static loading process, and the adiabatic change during the dynamic operation. Keywords : Vibration damping, hydraulic damping, gas laws 1. Introduction Mining Machines, like the ALPINE Miner of the Sandvik company in Fig. 1, are subject to severe vibrations during their operation. Measures for damping are re- quired. Goal of this project was to investigate the potential of damping oscillation using the hydraulic cylinders of the support jacks (Fig.
    [Show full text]
  • Don't Let Dollars Disappear up Your Chimney!
    ENERGY SAVINGTIPS DON’T LET DOLLARS DISAPPEAR UP YOUR CHIMNEY! You wouldn’t leave a window wide open in cold weather. Having a fireplace with an open flue damper is the same as having a window open. That sends precious winter heat and money right up the chimney! Here’s how you can heat your home, and not the neighborhood! KEEP THE FIREPLACE DAMPER CLOSED WHEN THE FIREPLACE IS NOT BEING USED The damper is a flap inside the chimney or flue. It has an open and a closed position. When a fire is burning, the damper should be in the open position to allow smoke to escape up the fireplace flue and out the chimney. When you’re not using the fireplace, the damper should be closed. If you can’t see the handle or chain that opens and closes the damper, use a flashlight and look up inside the chimney flue. The handle could be a lever that moves side to side or back and forth. If a chain operates the damper, you may have to pull both sides to determine which one closes or opens the damper. KEEP YOUR HEAT IN YOUR HOME! Even the most energy efficient homes can fall victim to fireplace air leaks. Your fireplace may be reserved for a handful of special occasions or especially cold nights. When it’s not in use, though, your home loses heat – and costs you money – without you knowing it. Using the heat from your fireplace on a cold winter night may be cozy, but that fire is a very inefficient way to warm up the room.
    [Show full text]
  • Indoor Air Quality (IAQ): Combustion By-Products
    Number 65c June 2018 Indoor Air Quality: Combustion By-products What are combustion by-products? monoxide exposure can cause loss of Combustion (burning) by-products are gases consciousness and death. and small particles. They are created by incompletely burned fuels such as oil, gas, Nitrogen dioxide (NO2) can irritate your kerosene, wood, coal and propane. eyes, nose, throat and lungs. You may have shortness of breath. If you have a respiratory The type and amount of combustion by- illness, you may be at higher risk of product produced depends on the type of fuel experiencing health effects from nitrogen and the combustion appliance. How well the dioxide exposure. appliance is designed, built, installed and maintained affects the by-products it creates. Particulate matter (PM) forms when Some appliances receive certification materials burn. Tiny airborne particles can depending on how clean burning they are. The irritate your eyes, nose and throat. They can Canadian Standards Association (CSA) and also lodge in the lungs, causing irritation or the Environmental Protection Agency (EPA) damage to lung tissue. Inflammation due to certify wood stoves and other appliances. particulate matter exposure may cause heart problems. Some combustion particles may Examples of combustion by-products include: contain cancer-causing substances. particulate matter, carbon monoxide, nitrogen dioxide, carbon dioxide, sulphur dioxide, Carbon dioxide (CO2) occurs naturally in the water vapor and hydrocarbons. air. Human health effects such as headaches, dizziness and fatigue can occur at high levels Where do combustion by-products come but rarely occur in homes. Carbon dioxide from? levels are sometimes measured to find out if enough fresh air gets into a room or building.
    [Show full text]
  • Fundamentals of Venting and Ventilation
    Fundamentals of Venting and Ventilation • Vent System Operation • Sizing, Design and Applications • Installation and Assembly • Troubleshooting © American Standard Inc. 1993 Pub. No. 34-4010-02 Contents Subject Page • Motive force in vents ................................................................................................................................... 2 • Factors affecting operation ......................................................................................................................... 3 • Ventilation air requirements........................................................................................................................ 4 • Vent design considerations - ....................................................................................................................... 6 – Category I furnaces............................................................................................................................... 6 – Category II furnaces.............................................................................................................................. 6 – Category III furnaces ............................................................................................................................. 6 – Category IV furnaces ............................................................................................................................ 7 • Types of vents .............................................................................................................................................
    [Show full text]
  • System Controls Engineering Guide
    SECTION G Engineering Guide System Controls System Controls Engineering Guide Introduction to VAV Terminal Units The control of air temperature in a space requires that the loads in the space are offset by some means. Space loads can consist of exterior loads and/or interior loads. Interior loads can consist of people, mechanical equipment, lighting, com puters, etc. In an 'air' conditioning system compensating for the loads is achieved by introducing air into the space at a given temperature and quantity. Since space loads are always fluctuating the compensation to offset the loads must also be changing in a corresponding manner. Varying the air temperature or varying the air volume or a combination of both in a controlled manner will offset the space load as required. The variable air volume terminal unit or VAV box allows us to vary the air volume into a room and in certain cases also lets us vary the air temperature into a room. YSTEM CONTROLS YSTEM S The VAV terminal unit may be pressure dependent or pressure independent. This is a function of the control package. ENGINEERING GUIDE - Pressure Dependent A device is said to be pressure dependent when the flow rate passing through it varies as the system inlet pressure fluctuates. The flow rate is dependent only on the inlet pressure and the damper position of the terminal unit. The pressure dependent terminal unit consists of a damper and a damper actuator controlled directly by a room thermostat. The damper is modulated in response to room temperature only. Since the air volume varies with inlet pressure, the room may experience temperature swings until the thermostat repositions the damper.
    [Show full text]
  • Furnaces CO Emissions Under Normal and Compromised Vent
    FURNACE CO EMISSIONS UNDER NORMAL AND COMPROMISED VENT CONDITIONS FURNACE #5 - HIGH-EFFICIENCY INDUCED DRAFT September 2000 Prepared by Christopher J. Brown Ronald A. Jordan David R. Tucholski Directorate for Laboratory Sciences The United States Consumer Product Safety Commission Washington, D.C. 20207 1. INTRODUCTION .................................................................................................................. 1 2. TEST EQUIPMENT AND SETUP ........................................................................................ 1 a. Furnace................................................................................................................................ 1 b. Test Chamber and Furnace Closet ...................................................................................... 3 c. Vent Blockage Device and Vent Disconnect...................................................................... 3 d. Measuring Equipment......................................................................................................... 4 i) Furnace Operating Parameters........................................................................................ 4 ii) Gas Sampling Systems.................................................................................................... 5 iii) Air Exchange Rate ..........................................................................................................5 iv) Room Temperature, Pressure, and Relative Humidity ................................................... 6 v) Natural
    [Show full text]