516 PHOENIX CONTACT Controllers

Suitable for all requirements Compact controller system - Easy Automation From distributed water supply to highly complex painting lines in the automotive Product overview 518 industry – reliable and cost-effective automation with controllers from Controllers Phoenix Contact. The broad spectrum Product overview 520 offers innovative control solutions from Programmable logic modules 524 programmable logic modules to high-end Compact controllers 532 controllers. Axiocontrol controllers 536 Programmable logic modules High-performance controllers 538 Minimal effort with maximum benefits – for Nanoline programmable logic modules Software PLC 542 the focus is on simplicity and flexibility. Starter kits 544 Control basic applications reliably with Nanoline. Services for automation 546 Compact controllers Class 100 programmable logic controllers impress with their high function density at low prices. They support all common com- munication paths and can be easily extend- ed. In short, they are ideal for simple re- quirements, even in distributed systems.

Axiocontrol controllers Axiocontrol controllers are fast, robust, and user-friendly, i.e., they are all designed for maximum performance, easy handling, and use in harsh industrial environments. High-performance controllers Automation at the highest level: class 300 and 400 PLCs are high-performance high- end controllers for moderate to demanding tasks. Software PLC Two devices in one: utilize the available resources of your industrial PC and trans- form it into a powerful controller using the software PLC.

PHOENIX CONTACT 517 Controllers Compact controller system – Easy Automation – product overview

Class 100 compact controllers

Typ e ILC 131 ETH ILC 151 ETH ILC 171 ETH 2TX ILC 191 ETH 2TX ILC 151 GSM/GPRS ILC 131 STARTERKIT Order No. 2700973 2700974 2700975 2700976 2700977 2701835 Description Class 100 compact controllers are at the heart of the Easy Automation system from Phoenix Contact. Starter kit for easy entry into As the interface between the control center and I/O level, they efficiently control the data flow within your system. the world of automation

Page 532 533 533 533 534 544

Software

Typ e PC Worx EXPRESS PROJECT+ WEBVISIT 6 EXPRESS SAFECONF SD FLASH 2GB APPLIC A SD FLASH 256MB PDPI BASIC Order No. 2988670 2988667 2700954 2986119 2701190 2700551 Typ e SD FLASH 2GB SD FLASH 256MB PDPI PRO Order No. 2988162 2700552 Description Engineering software, Software for I/O configuration Software for Configuration software for SD card with license for SD card with license for for programming according to web-based visualizations SafetyBridge modules IT and controller function blocks controller function blocks IEC 61131 with self-optimization

Page 499 514 503 110 501 501

Industrial network technology

Typ e FL SWITCH SFN 5TX FL SWITCH SFN 4TX/FX FL BT EPA AIR SET FL WLAN EPA PSI-MODEM/ETH PSI-MODEM-3G/ROUTER Order No. 2891152 2891851 2693091 2692791 2313300 2314008 Typ e FL SWITCH SFN 8TX FL SWITCH SFN 6TX/2FX Order No. 2891929 2891314 Description Standard switches Standard switches Bluetooth transmission of an WLAN transmission of an Connection via Connection via with fiber optics Ethernet connection Ethernet connection a telephone line a mobile phone network

Page 8 9 53 51 428 423

Panels for operation and monitoring

Typ e TD 1030T WP 04T WP 06T WP 07T/WS WP09T/WS Order No. 2701257 2913632 2913645 2700307 2700309 Description 4:3 4:3 4:3 Widescreen Widescreen 7.1 cm (2.8") display 8.9 cm (3.5") display 14.5 cm (5.7") display 17.8 cm (7") display 22.9 cm (9") display

Page 120 120 120 121 121

518 PHOENIX CONTACT Controllers Compact controller system – Easy Automation – product overview

I/O systems for the control cabinet (IP20)

Digital input 1 channel 2 channels 4 channels 8 channels 16 channels 32 channels IB IL 120 DI 1-PAC IB IL 24 DI 2-PAC IB IL 24 DI 4-PAC IB IL 24 DI 8-PAC IB IL 24 DI 16-PAC IB IL 24 DI 32/HD-PAC 2861917 2861221 2861234 2861247 2861250 2862835 IB IL 230 DI 1-PAC IB IL 24 DI 2-NPN-PAC IB IL 24 DI 4-ME IB IL 24 DI 8/T2-PAC IB IL 24 DI 16-NPN-PAC IB IL 24 DI 32/HD-NPN-PAC 2861548 2861483 2863928 2862204 2863520 2878243 IB IL 24 DI8/HD-PAC IB IL 24 DI 16-ME 2700173 2897156

From page 204 200 200 201 200 201

Digital output Security 1 channel 2 channels 4 channels 8 channels 16 channels 32 channels IB IL DO 1 AC-PAC IB IL 24 DO 2-PAC IB IL 24 DO 4-PAC IB IL 24 DO 8-PAC IB IL 24 DO 16-PAC IB IL 24 DO 32/HD-PAC 2861920 2861276 2861276 2861289 2861292 2862822 IB IL 24 DO 2-2A-PAC IB IL 24 DO 4-ME IB IL 24 DO 8-2A-PAC IB IL 24 DO 16-ME IB IL 24 DO 32/HD-NPN-PAC See section: 2861263 2863931 2861603 2897253 2878340 functional safety IB IL 24 DO 2-NPN-PAC IB IL DO 4-AC-1A-PAC IB IL 24 DO 8-NPN-PAC 2861496 2861658 2863546 IB IL 24 DO8/HD-PAC 2700172

210 206 206 206 206 207 105

Relay output terminals (PDT contacts) Analog input Analog output 1 PDT 2 PDTs 4 PDTs 2 channels 8 channels 1 channel 4 or 8 channels IB IL 24/230 DOR1/W-PAC IB IL 24/48 DOR 2/W-PAC IB IL 24/230 DOR4/W-PAC IB IL AI 2/SF-PAC IB IL AI 8/SF-PAC IB IL AO 1/SF-PAC IB IL AO 4/8/U/BP-PAC 2861881 2863119 2861878 2861302 2861412 2861315 2878036 IB IL 24/230 DOR1/W-PC-PAC IB IL 24/230 DOR4/W-PC-PAC IB IL AI 2/SF-ME IB IL AI 8/IS-PAC IB IL AO 1/U/SF-PAC 2862178 2862181 2863944 2861661 2861399 IB IL 24/230 DOR4/HC-PAC 2897716

211 211 211 212 213 220 221

Strain gauge Temperature recording 2 channels 2 channels 1 channel 2 channels 2 channels 4/8 channels IB IL SGI 2/F-PAC IB IL SGI 2/P-PAC IB IL 24 TC-PAC IB IL TEMP 2 UTH-PAC IB IL TEMP 2 RTD-PAC IB IL TEMP 4/8 RTD/EF-PAC 2878638 2884907 2861360 2861386 2861328 2897402 IB IL TEMP 4/8 RTD-PAC 2863915

216 216 219 218 219 219

Communication Position detection Function Motor starter Intrinsically safe I/Os for Ex applications

IB IL RS 232-PAC IBS IL 24 RB-T-PAC IB IL INC-IN-PAC IB IL PWM/2-PAC IB IL 400 ELR 1-3A IB IL EX-IS PWR IN-PAC IB IL EX-IS AIO 4/EF-PAC 2861357 2861441 2861755 2861632 2727352 2869910 2869912 IB IL RS 232-PRO-PAC IB IL 24 IOL 4 DI 12-PAC IB IL SSI-IN-PAC IB IL CNT-PAC IB IL 400 MLR 1-8A IB IL EX-IS DIO 4/NAM- IB IL EX-IS TEMP 2878722 2692717 2819574 2861852 2727365 PAC 4 RTD/TC-PAC IB IL RS 485/422-PAC IB IL IFS-MA-PAC IB IL 400 ELR R-3A 2869911 2869913 2861933 2692720 2727378

228 226 238 234 242 490 492

I/O systems for field installation (IP65/IP67)

Digital input Digital input/output Digital output terminals

8 channels 16 channels 4/4 channels 8/8 channels 16/16 channels 8 channels FLM DI 8 M12 FLM DI 16 M12 FLM DIO 4/4 M12-2A FLM DIO 8/8 M12 FLM DIO 16/16 M12/8-DIAG FLM DO 8 M12 2736288 2736835 2736369 2736848 2736738 2736291

298 298 299 299 299 299

Analog input Temperature recording Wireless

4 channels 4 channels Base station 8/8 channels 16 channels FLM AI 4 SF M12 FLM TEMP 4 RTD M12 FLM BT BS 3 FLM BT DIO 8/8 M12 FLM BT DI 16 M12 2736453 2736819 2736770 2736767 2693208

301 301 457 457 457

Digital input Digital input/output Digital output terminals

8 channels 4(8)/4 channels 4 channels 8 channels FLM DI 8 M8 FLM DIO 8/4 M8 FLM DO 4 M8-2A FLM DO 8 M8 2773348 2773351 2736932 2736893

302 303 303 303

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 519 Controllers Product overview

Programmable logic modules

Typ e NLC-055-… NLC-IO-… NLC-COM-… NLC-OP1-… NLC-MOD-… Description Basic unit with digital I/O extension modules with Communication extension modules Control panel for interactions with Slot 1 option module, inputs and outputs digital inputs and outputs, for Ethernet and GSM networks the Nanoline system extension modules for relay outputs, and analog inputs serial communication

Page 524 526 528 529 530

Programmable logic modules Steeplechase VLC

Typ e NLC-MOD-… NLC-START-… ILC 150 VLC ILC 350 VLC Description Slot 2 option module, Starter kit, for easy entry into the Steeplechase VLC offers a scalable solution for controlling your applications. Realtime clock, memory module Nanoline controller range The ILC 150 VLC and ILC 350 VLC are cost-effective PLCs with integrated VLC runtime and easy-to-operate onboard I/Os

Page 531 526 www.phoenixcontact.net/products

Compact controllers Class 100

Typ e ILC 131/151 ... ILC 171/191 ... ILC 131/151 XC ILC 151 GSM/GPRS ILC 191 ME/INC, .../AN Description Class 100 compact controllers impress thanks to their Class 100 compact controller Class 100 compact controller Class 100 compact controller high function density at low prices with extended temperature range with integrated GSM/GPRS modem for easy drive control

Page 532 533 532 534 535

Class 100 Class 200

Typ e ILC 131 STARTERKIT PSK DL … ILC 200 UNI-PAC ILC 200 IB-PAC Description Starter kit for easy entry into the Complete packages for data logging Class 200 rounds off the controller hardware world of automation See section: within the compact controller class with integrated special functions, Monitoring tailored to machine building applications

Page 544 See Catalog 7 www.phoenixcontact.net/products

520 PHOENIX CONTACT Controllers Product overview

Axiocontrol controllers High-performance controllers Class 1000 Class 3000 Class 300

Typ e AXC 1050 AXC 3050 ILC 330/350 … ILC 370/390 … PROFINET STARTERKIT 3.0 Description Axiocontrol compact controllers Axiocontrol high-performance Class 300 high-performance controllers offer Find out how is easy it is to create and with particularly robust housing controllers for the automation of significantly higher performance thanks to more powerful hardware start up PROFINET IO networks and integrated UPS challenging applications

Page 536 537 538 539 545

Class 400

Typ e RFC 470(S) PN 3TX RFC 460R PN 3TX RFC 430/450 ETH-IB S-MAX 400 CE PN … S-MAX 41x CE PN Description Powerful class 400 high-performance controllers offer maximum performance and functionality

Page 540 541 www.phoenixcontact.net/products

Software PLC Box PCs System cabling Memory card

Typ e PC Worx SRT PC Worx RT BASIC Valueline IPC SD FLASH... / CF FLASH... Description Software PLC Software PLC See section: See section: See section: without realtime extension with realtime extension HMIs and industrial PCs System cabling for controllers Software

Page 542 543 130 See Catalog 7 501

Services for automation Software for control technology Service Training Engineering

Typ e PC Worx EXPRESS PC Worx Description Hotline Individual training concepts Configuration Onsite service Training Programming See section: Startup support Visualization Software Professional workshops Coaching

Page 546 499

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 521 Controllers Programmable logic modules Nanoline logic module

Minimal effort with maximum benefits – for Nanoline programmable logic modules the focus is on simplicity and flexibility. This means a modular and adaptable design with 80,5 60 optimum networking options. For tailored use, optionally connect a logic module to PWR nanoLine other modules: I/O expansion module, RUN communication module, operator panel, re- 1 2 altime clock. 103,5 24 V DC, 8 digital inputs, Your advantages: 2 analog inputs and 4 relay outputs – Save time – by intelligently controlling ba- sic tasks – Easy use without prior knowledge, thanks  to intuitive programming with flowcharts – Versatile communication with numerous Technical data integration and networking options Power supply – Maximum flexibility, thanks to the modu- Supply voltage 24 V DC (power available to the I/O and communications modules) 12 V DC (power available to the I/O and communicat lar design Supply voltage range 19.2 V DC ... 30 V DC Typical current consumption 150 mA Additional features: Max. current consumption 250 mA – Modules for different operating voltages, Digital inputs Number of inputs 8 available in 24 V DC, 12 V DC or Description of the inputs EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP 110 ... 240 V AC Typical response time 20 ms (on) Digital outputs – Supports 4 mathematical functions and Number of outputs 4 includes 2 high-speed counters and 2 ana- Description of the outputs Relay output log inputs. Maximum output current per channel 5 A Maximum output current per module / terminal block 20 A – Integrated digital I/Os Protective circuit External protection required External protection required Short-circuit and overload protection External protect – Add up to 3 additional digital and analog Analog_Input I/O expansion modules for a maximum of Number of inputs 2 Voltage input signal 0 V DC ... 10 V DC 44 I/O points Counter input – An operator panel can be optionally inte- Number of inputs 2 Input frequency 6 kHz grated in the logic module or installed re- Software interfaces motely on a panel Programming tool nanoNavigator 3 or above nanoNavigator 3 or above nanoNavigator 3 or above nanoNavigator 3 or above – Integrated realtime clock (RTC) Realtime clock Yes (battery-backed) Precision ±2 s/day @ 25°C – Optional USB, RS-232 or RS-485 modules ±4 s/day @ -20°C +60°C for connection to a PC for configuration General data Connection method Screw connection download Weight 262 g – Optional RS-232 and RS-485 allow you to Degree of protection IP20 use your logic module as a /RTU Ambient temperature (operation) -25 °C ... 60 °C server Ordering data – Intuitive programming language with op- Pcs. / Description Type Order No. tions for flowcharts and ladder diagrams. Pkt.

Notes: Nanoline controller, requires nanoNavigator 3 or above

1) EMC: Class A product, see page 553 - 8 digital inputs, 2 analog inputs, 4 DC relay outputs NLC-055-024D-08I-04QRD-05A 2700464 1

- 8 digital inputs, 2 analog inputs and 4 PNP digital outputs

- 8 digital inputs and 4 relay outputs

Accessories Cover, replacement Operator panel NLC-OP1-COVER 2701276 1 Cap, replacement Slot 1 NLC-MOD-CAP 2701289 1 Cap, replacement Slot 2 NLC-MOD-CAP-PXC 2701292 1

522 PHOENIX CONTACT Controllers Programmable logic modules

12 V DC, 8 digital inputs, 24 V DC, 8 digital inputs, 100240 V AC, 8 digital inputs 2 analog inputs and 4 relay outputs 2 analog inputs and 4 PNP digital outputs and 4 relay outputs

Technical data Technical data Technical data

Supply voltage 24 V DC (power available to the I/O and communications modules) 12 V DC (power available to the I/O and communications modules) 24 V DC (power available to the I/O and communications modules) 240 V AC (power available to the I/O and communications modules)

9 V DC ... 15 V DC 19.2 V DC ... 30 V DC - 250 mA 100 mA 50 mA (at 230 V AC) 400 mA 250 mA 70 mA (at 110 V AC)

888 Description of the inputs EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP 20 ms (on) 60 µs (on) 20 ms (on)

444 Relay output PNP outputs Relay output 5 A 500 mA 5 A 20 A 2 A 20 A Protective circuit External protection required External protection required Short-circuit and overload protection External protection required

22- 0 V DC ... 10 V DC 0 V DC ... 10 V DC -

22- 6 kHz 6 kHz -

Programming tool nanoNavigator 3 or above nanoNavigator 3 or above nanoNavigator 3 or above nanoNavigator 3 or above Yes (battery-backed) Yes (battery-backed) Yes (battery-backed) ±2 s/day @ 25°C ±2 s/day @ 25°C ±2 s/day @ 25°C ±4 s/day @ -20°C +60°C ±4 s/day @ -20°C +60°C ±4 s/day @ -20°C +60°C

Screw connection Screw connection Screw connection 248 g 178 g 150 g IP20 IP20 IP20 -25 °C ... 60 °C -25 °C ... 60 °C -25 °C ... 60 °C Ordering data Ordering data Ordering data

Pcs. / Pcs. / Pcs. / Type Order No. Type Order No. Type Order No. Pkt. Pkt. Pkt.

NLC-055-012D-08I-04QRD-05A 2700486 1

NLC-055-024D-08I-04QTP-00A1) 2700453 1

NLC-055-100A-08I-04QRA-05A 2700487 1

Accessories Accessories Accessories

NLC-OP1-COVER 2701276 1 NLC-OP1-COVER 2701276 1 NLC-OP1-COVER 2701276 1

NLC-MOD-CAP 2701289 1 NLC-MOD-CAP 2701289 1 NLC-MOD-CAP 2701289 1

NLC-MOD-CAP-PXC 2701292 1 NLC-MOD-CAP-PXC 2701292 1 NLC-MOD-CAP-PXC 2701292 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 523 Controllers Programmable logic modules Nanoline logic module

Minimal effort with maximum benefits – for Nanoline programmable logic modules the focus is on simplicity and flexibility. This means a modular and adaptable design with 80,5 60 optimum networking options. For tailored use, optionally connect a logic module to PWR nanoLine other modules: I/O expansion module, RUN communication module, operator panel, re- 1 2 altime clock. 103,5 24 V DC, 6 digital inputs Your advantages: and 4 NPN/PNP outputs – Save time – by intelligently controlling ba- sic tasks – Easy use without prior knowledge, thanks   to intuitive programming with flowcharts – Versatile communication with numerous Technical data integration and networking options NLC-050-024D-06I-04QTN- NLC-050-024D-06I-04QTP-00A 00A1) – Maximum flexibility, thanks to the modu- Power supply lar design Supply voltage 24 V DC (power available to the I/O and communications modules) 24 V DC (power available to the I/O and communicat Additional features: Supply voltage range 19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC 19 V DC ... 30 V DC 100 V AC ... 240 V AC Typical current consumption 92 mA 150 mA 150 mA (@ 24 V AC/DC) 70 mA (@ 230 – Modules for different operating voltages, Max. current consumption 250 mA 250 mA 250 mA - available in 24 V DC, 24 V AC/DC or Digital inputs 110 ... 240 V AC Number of inputs 6688 Description of the inputs EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP – Integrated digital I/Os Typical response time 60 µs (on) 60 µs (on) 20 ms 20 ms – Add up to 3 additional digital and analog Digital outputs I/O extension modules for a maximum of Number of outputs 4444 Description of the outputs NPN outputs PNP outputs Relay output Relay output Relay output 42 I/O points Maximum output current per channel 500 mA 5 A 5 A 5 A – An operator panel can be optionally inte- Maximum output current per module / terminal block 2 A 20 A 20 A 20 A Protective circuit Short-circuit and overload protection Short-circuit and overload protection Short-circuit and overload protecti grated in the logic module or installed re- Software interfaces motely on a panel Programming tool nanoNavigator 1 or 2 nanoNavigator 1 or 2 nanoNavigator 1 or 2 nanoNavigator 1 or 2 – Integrated realtime clock (RTC) Realtime clock Optional module Optional module Optional module Optional module Precision – Optional USB, RS-232 or RS-485 modules General data for connection to a PC for configuration Connection method Screw connection Screw connection Screw connection Screw connection download Weight 240 g 260 g 248 g 268 g Degree of protection IP20 IP20 IP20 IP20 – Optional RS-232 and RS-485 allow you to Ambient temperature (operation) -25 °C ... 60 °C -25 °C ... 60 °C -25 °C ... 60 °C -25 °C ... 55 °C use your logic module as a Modbus/RTU Ordering data server Pcs. / – Intuitive programming language with op- Description Type Order No. Pkt. tions for flowcharts and ladder diagrams. Nanoline controller, requires nanoNavigator 1 or 2 Notes: - 6 digital inputs, 4 NPN outputs NLC-050-024D-06I-04QTN-00A1) 2701030 1 1) EMC: Class A product, see page 553 - 6 digital inputs, 4 PNP outputs NLC-050-024D-06I-04QTP-00A 2701027 1 - 6 digital inputs, 4 DC relay outputs

- 8 digital inputs, 4 AC/DC relay outputs

- 8 digital inputs, 4 AC/DC relay outputs

Accessories Cover, replacement Operator panel NLC-OP1-COVER 2701276 1 Cap, replacement Slot 1 NLC-MOD-CAP 2701289 1 Cap, replacement Slot 2 NLC-MOD-CAP-PXC 2701292 1

524 PHOENIX CONTACT Controllers Programmable logic modules

24 V DC, 6 digital inputs 24 V AC/DC, 8 digital inputs 100 - 240 V AC, 8 digital inputs and 4 relay outputs and 4 relay outputs and 4 relay outputs

 

Technical data Technical data Technical data

Supply voltage 24 V DC (power available to the I/O and communications modules) 24 V DC (power available to the I/O and communications modules) 24 V AC/DC (power available to the I/O and communications mod- 100 V AC ules) 240 V AC (power available to the I/O and communications modules) Supply voltage range 19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC 19 V DC ... 30 V DC 100 V AC ... 240 V AC Typical current consumption 92 mA 150 mA 150 mA (@ 24 V AC/DC) 70 mA (@ 230 V AC) 250 mA 250 mA 250 mA -

6688 Description of the inputs EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP EN 61131-2 type 1 NPN/PNP 60 µs (on) 60 µs (on) 20 ms 20 ms

4444 Description of the outputs NPN outputs PNP outputs Relay output Relay output Relay output Maximum output current per channel 500 mA 5 A 5 A 5 A Maximum output current per module / terminal block 2 A 20 A 20 A 20 A Protective circuit Short-circuit and overload protection Short-circuit and overload protection Short-circuit and overload protection Short-circuit and overload protection nanoNavigator 1 or 2 nanoNavigator 1 or 2 nanoNavigator 1 or 2 nanoNavigator 1 or 2 Optional module Optional module Optional module Optional module ---

Screw connection Screw connection Screw connection Screw connection 240 g 260 g 248 g 268 g IP20 IP20 IP20 IP20 Ambient temperature (operation) -25 °C ... 60 °C -25 °C ... 60 °C -25 °C ... 60 °C -25 °C ... 55 °C Ordering data Ordering data Ordering data

Pcs. / Pcs. / Pcs. / Type Order No. Type Order No. Type Order No. Pkt. Pkt. Pkt.

NLC-050-024D-06I-04QRD-05A1) 2701043 1

NLC-050-024X-08I-04QRX-05A 2701056 1

NLC-050-100A-08I-04QRA-05A 2701069 1

Accessories Accessories Accessories

NLC-OP1-COVER 2701276 1 NLC-OP1-COVER 2701276 1 NLC-OP1-COVER 2701276 1

NLC-MOD-CAP 2701289 1 NLC-MOD-CAP 2701289 1 NLC-MOD-CAP 2701289 1

NLC-MOD-CAP-PXC 2701292 1 NLC-MOD-CAP-PXC 2701292 1 NLC-MOD-CAP-PXC 2701292 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 525 Controllers Programmable logic modules Nanoline starter kits

The Nanoline starter kit provides everything needed to get started with the Nanoline controller: – Logic module – Operator panel – Input simulator (24 V AC or 24 V DC versions available) – Output simulator (24 V AC or 24 V DC versions available) – Serial USB module Nanoline starter kit –USB cable –Quick start guide Ordering data

Pcs. / Description Type Order No. Pkt. Starter kit, consisting of: Base unit, operator panel, USB serial module and USB cable, input and output simulators - Logic module (2701030 NLC-050-024D-06I-04QTN-00A) NLC-START-01 2701399 1 with 6 digital inputs and 4 NPN digital outputs

- Logic module (2701027 NLC-050-024D-06I-04QTP-00A) NLC-START-02 2701425 1 with 6 digital inputs and 4 PNP digital outputs

- Logic module (2700464 NLC-055-024D-08I-04QRD-05A) NLC-START-03 2701467 1 with 8 digital inputs, 2 analog inputs and 4 relay outputs

Deluxe starter kit, consisting of: Logic module (2700453 NLC-055-024D-08I-04QTP-00A) with 8 digital inputs, 2 analog inputs and 4 PNP digital outputs, operator panel, USB serial module and USB cable, input and output simula- tors, PNP digital expansion, I/O module, Ethernet module, STEP POWER power supply unit NLC-START-04 2701483 1

Nanoline digital I/O expansion module 40 43 Depending on the required I/Os, you can extend your Nanoline logic module with ad- ditional I/O expansion modules. The combi- nanoLineController nation of digital and analog I/Os may vary. Digital I/O expansion modules provide additional inputs and outputs beyond what 103,5 is available on the logic module: – Up to 3 modules can be added to the right side of a logic module – Automatically recognized by 3/6 inputs, 4 PNP/NPN outputs nanoNavigator – I/O modules are electrically isolated Technical data – Can be powered from a secondary power NLC-IO-06I-04QTP-01A NLC-IO-03I-04QRD-05A supply Power supply for module electronics Supply voltage 24 V DC 24 V AC/DC Notes: Digital inputs 1) EMC: Class A product, see page 553 Maximum number of inputs 6 3 Description of the inputs PNP/NPN Digital outputs Maximum number of outputs 4 Maximum output current per channel 500 mA 5 A Maximum output current per module / terminal block 2 A 20 A Ordering data

Pcs. / Description Type Order No. Pkt. Nanoline controllers, I/O expansion module

- 6 digital inputs, 4 PNP outputs NLC-IO-06I-04QTP-01A 2701072 1 - 6 digital inputs, 4 NPN outputs NLC-IO-06I-04QTN-01A1) 2701085 1 - 3 digital inputs, 4 DC relay outputs NLC-IO-03I-04QRD-05A 2701328 1

526 PHOENIX CONTACT Controllers Programmable logic modules Nanoline analog I/O expansion module

Analog I/O expansion modules provide additional inputs and outputs beyond what is available on the logic module: – A system may have up to 8 analog inputs 40 43 and 8 analog outputs. – Configuration options for 0 ... 10 V DC, ±10 V DC, 4 ... 20 mA, and 0 ... 20 mA nanoLineController inputs. – Configuration options for 0 ... 10 V DC, 4 ... 20 mA, and 0 ... 20 mA outputs. 103,5 Analog I/O extension module – Up to 3 modules can be added to the right side of a logic module – Automatically recognized by nanoNavigator – I/O modules are electrically isolated Technical data

– Can be powered from a secondary power NLC-IO-2AI-2AO-011) NLC-IO-4AI1) supply Power supply for module electronics Supply voltage 24 V DC Notes: Analog inputs 1) EMC: Class A product, see page 553 Connection method Screw connection Number of inputs 2 (voltage or current 4 (voltage or current can be chosen separately) can be chosen separately) Description of the input Single ended Precision 1% Voltage input signal 0 V ... 10 V / -10 V ... 10 V Current input signal 0 mA ... 20 mA / 4 mA ... 20 mA Resolution A/D 12 bit Limit frequency (3 dB) 5 Hz Analog outputs Connection method Screw connection - Number of outputs 2 - Precision 1% - D/A resolution 12 bit - Voltage output signal 0 V ... 10 V - Load/output load voltage output 1000 Ω - Current output signal 0 mA ... 20 mA / 4 mA ... 20 mA - Load/output load current output 500 Ω - General data Connection method Screw connection Ambient temperature (operation) -25 °C ... 60 °C Ordering data

Pcs. / Description Type Order No. Pkt. Nanoline controllers, I/O expansion module

2 analog inputs, 2 analog outputs NLC-IO-2AI-2AO-011) 2701040 1 4 analog inputs NLC-IO-4AI1) 2701098 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 527 Controllers Programmable logic modules Nanoline Ethernet communication expansion module 40 43 The Ethernet expansion module enables optimum integration of Nanoline in your network. In combination with the Ethernet Ethernet expansion module, you can also use your Nanoline logic module as a Modbus/TCP LNK / ACT Module

103,5 server. Network You can therefore read and write I/O points, registers, timers, counters, and pro- gram and system flags – independently of the program and from any location. 10/100 Mbps, Modbus TCP server – Read only or read/write access control – Watchdog timer monitors communica- Technical data tion, providing either a warning or fault Interface Interface Ethernet 10/100Base T Note: one of the serial connection op- Connection method RJ45 Transmission speed 10/100 Mbps (autonegotiation) tion modules is required to configure and Transmission length 100 m program the Nanoline controller. Signal LEDs LNK/ACT; module; network Power supply for module electronics Notes: Supply voltage 24 V DC (Power available via logic module) Typical current consumption 110 mA 1) EMC: Class A product, see page 553 Ordering data

Pcs. / Description Type Order No. Pkt. Nanoline controllers, communication module Ethernet module for Modbus® TCP Server functionality NLC-COM-ENET-MB11) 2701124 1

Nanoline communication expansion module 80,5 43 The GSM module provides remote access to the Nanoline controller through SMS messaging: GSMModem – Allows access to read and write registers, Net Status flags, timers and counters. Signal – Switch outputs on and off 103,5 Error – Read inputs – Sends system faults and warning messages – Password protected to allow selective ac- cess or broadcast to an onboard address GSM communication book Technical data Wireless interface Wireless standard GSM-SMS Frequency band 850/900/1800/1900 MHz Antenna connection method SMA (female) Power supply for module electronics Supply voltage range 12 V DC ... 24 V DC (9.628.8 V DC) General data Wireless licenses R&TTE, FCC, AT&T, PTCRB Ordering data

Pcs. / Description Type Order No. Pkt. GSM communication expansion module NLC-COM-GSM 2701344 1 Accessories Multi-band antenna for UMTS and quad band GSM, with omnidi- PSI-GSM/UMTS-QB-ANT 2313371 1 rectional characteristics

528 PHOENIX CONTACT Controllers Programmable logic modules

Nanoline operator panel Notes: 1) EMC: Class A product, see page 553

The operator panel is your interface for interacting with the Nanoline system. Read the status of all I/O points, registers, timers, counters, and program and system flags di- rectly. In addition, the application program sends prompts and instructions to the dis- play. Unique feature: the operator panel offers numerical (0 - 9), direction (up, down, left, right), and input keys. In addition, each of User interface for Nanoline controllers the 14 keys on the operator panel can be used to create user-specific menus in a flow- chart.  Additional features: – The operator panel can be integrated in Technical data the logic module or installed remotely on Display data Display Backlit LC display, monochrome, 4 lines with 20 characters or 2 a panel (1 m distance) lines with 10 characters – The hot-swappable design enables use as Interfaces a service tool Operator Panel RJ45 Transmission length max. 1 m – Variable text sizes for enhanced readabili- Power supply for module electronics ty of custom messages (4 x 20 or 2 x 10 Supply voltage (Power available via logic module) Connection method RJ45 or a combination) Typical current consumption 32 mA Max. current consumption 50 mA General data Programming tool nanoNavigator Mounting type In logic module or with remote mounting kit

Keys 11 Height 46 mm Width 76 mm Depth 31.5 mm Degree of protection IP67/IP20 Ambient temperature (operation) 0 °C ... 50 °C Ambient temperature (storage/transport) 0 °C ... 60 °C Ordering data

Pcs. / Description Type Order No. Pkt. Operator panel NLC-OP1-LCD-032-4X201) 2701137 1 Accessories

Remote mounting kit, for Operator panel NLC-OP1-MKT1) 2701140 1

Base module for remote mounting Operator panel (included in nLC- NLC-OP1-MKT-BASE 2701250 1 OP1-MKT) Bracket for remote mounting Operator panel (included in nLC-OP1- NLC-OP1-MKT-BRACKET 2701263 1 MKT) Cable, RJ45 to RJ45 NLC-OP1-MKT-CBL 2701438 1

OK

15 14 13 12 11 10 COM

nanoLine

2

1 OK

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 529 Controllers Programmable logic modules

Serial Nanoline RS-232/RS-485 and Notes: USB connection modules 1) EMC: Class A product, see page 553

With its serial communication modules, the Nanoline system sets new standards in connectivity. This results in easy integration and distributed monitoring and control. Read and write I/O points, registers, tim- ers, counters, and program and system flags – With the RS-232 module, you can use your Nanoline logic module as a Mod- bus/RTU server. – Password control can limit access (read Serial connection for data transmission or only or read/write) software configuration – Watchdog timer monitors communica- tion, providing either a warning or fault 

Note: one of the serial connection op- Technical data tion modules is required to configure and Connection data program the Nanoline controller. Connection method Installs in slot 1 of logic module Use the RS-232 or USB module to con- Power supply for module electronics nect the logic module to your PC. From Supply voltage 24 V DC (Power available via logic module) here you can carry out configuration with Typical current consumption 10 mA Max. current consumption 18 mA the nanoNavigator software. General data Ambient temperature (operation) -25 °C ... 60 °C Ordering data

Pcs. / Description Type Order No. Pkt. Serial connection module, for data transfer

RS-232 layer, USB Type B connector NLC-MOD-USB 2701195 1 RS-232 layer, RJ11 connector NLC-MOD-RS2321) 2701179 1 RS-485 layer, RJ11 connector NLC-MOD-RS485 2701182 1 Accessories Serial cable, USB Type A to Type B NLC-PC/USB-CBL 2M 2701247 1 Serial cable, DB-9 to RJ11/12 NLC-PC/SERIAL-CBL 1M 2701234 1 RS-485 cable, RJ11 to open cable end NLC-RS485-CBL-5M 2701073 1

530 PHOENIX CONTACT Controllers Programmable logic modules

Nanoline realtime clock Notes: 1) EMC: Class A product, see page 553

For applications that require time or date functions, you can extend your Nanoline logic module with a realtime clock. Configuration is via the nanoNavigator software or operator panel. In this way, you can integrate numerous functions into your Nanoline system: – Optional on NLC-050 logic modules, standard on NLC-055 logic modules – Compare time and date information in Realtime clock for Nanoline controllers flowcharts – Calculate even and odd days Technical data – Adjust the time and date with other time Power supply components in the system Supply voltage 24 V DC (Power available via logic module) Typical current consumption 4 mA Max. current consumption 10 mA The realtime clock supports the following Realtime clock date formats: Realtime clock Yes (battery-backed) Precision 2 s/day at 25 °C – North American (month-day-year) 4.5 s/day overall (60ºC) – European (day-month-year) Battery Life 5 years – International (year-month-day) General data Ambient temperature (operation) -25 °C ... 60 °C Ordering data

Pcs. / Description Type Order No. Pkt. Realtime clock NLC-MOD-RTC1) 2701153 1

Nanoline memory module

Use the memory module to transmit projects: – From a PC to one or more Nanoline con- trollers without a direct connection – From one controller to another without a direct connection – From a controller to a replacement con- troller

Memory module for Nanoline controllers

Technical data Power supply Supply voltage - Typical current consumption 15 mA Max. current consumption 20 mA General data Ambient temperature (operation) -25 °C ... 60 °C Ordering data

Pcs. / Description Type Order No. Pkt. Memory module, for data transfer NLC-MOD-MEM 032K 2701166 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 531 Controllers Compact controllers

Class 100 controllers Notes: 1) EMC: Class A product, see page 553

Class 100 programmable logic controllers impress with their high function density at low prices. They support all common com- munication paths, such as Ethernet, mobile phone or fixed-line network. The controllers can be easily extended with Inline I/O modules and offer an inte- grated web server. As the interface between the control center and I/O level, they effi- ciently control the data flow of your system. Compact controller – basic device Compact controller In short, they are ideal for small to medium- sized applications, even in distributed sys- tems.  Ex:  Your advantages: – Maximum flexibility - numerous I/Os and Technical data special function modules can be mounted ILC 131 ETH1) ILC 131 ETH/XC1) ILC 151 ETH Interfaces side by side INTERBUS local bus (master) Inline data jumper – Cost-effective solution, thanks to the ex- Ethernet RJ45 socket cellent price/performance ratio with high Parameterization/operation/diagnostics RS-232-C, 6-pos. MINI-DIN socket (PS/2), Ethernet 10/100 (RJ45) function density INTERBUS master – Optimum communication - with integrat- Number of possible parameter channels max. 8 Number of I/O nodes max. 4096 ed, freely programmable web server for Number of supported devices max. 63 visualization with the WebVisit software Direct I/Os – Versatile use, as all common IT protocols Number of inputs 8 Number of outputs 4 are supported IEC-61131 runtime system Programmable under PC WorX in IEC 61131 PC WorX in IEC 61131 PC WorX in IEC 61131 PC WorX in IEC 61131 Additional features: Processing speed 1.7 ms (1 K mix instructions) – Modbus/TCP is integrated in the firmware 90 µs (1 K bit instructions) Program memory 192 kbyte (16 K instructions (IL)) 256 kbyte (21 K instructions (IL)) 512 kbyte (43 K instructions (IL)) 1 Mbyte (86 - this increases performance and simpli- Data memory 192 kbyte fies configuration. This makes communi- Retentive data memory 8 kbyte (NVRAM) cation with other Modbus devices even Number of data blocks (depends on data memory) (depends on data memory) (depends on data memory) (depends on data memory) Number of timers, counters (depends on data memory) (depends on data memory) (depends on data memory) (depends on data memory) easier Number of control tasks 8 – SD card slot: for quick memory expansion Realtime clock Yes and easy enabling of software blocks Power supply Supply voltage 24 V DC –FTP server Supply voltage range 19.2 V DC ... 30 V DC – Flash file system Typical current consumption 210 mA General data – Complete master (4096 I/O Width 80 mm points) Height 119.8 mm – Numerous protocols supported such as: Depth 71.5 mm Degree of protection IP20 HTTP, FTP, SNTP, SNMP, SMTP, SQL, Ambient temperature (operation) -25 °C ... 55 °C -40 °C ... 60 °C -25 °C ... 55 °C -40 °C ... 60 °C -25 °C ... 55 °C -25 °C ... 55 °C MySQL, etc. Ordering data – Intuitive programming using PC Worx or Pcs. / using the free PC Worx EXPRESS soft- Description Type Order No. ware Pkt. Compact controller, complete with accessories (connector plug – The XC versions are also suitable for and marking field) increased temperature requirements ILC 131 ETH1) 2700973 1 (-40°C to +60°C) ILC 131 ETH/XC1) 2701034 1 Accessories Programming cable PRG CAB MINI DIN 2730611 1 Parameterization memory, replaceable - 256 MB - 2 GB SD FLASH 2GB 2988162 1 - 512 MB SD FLASH 512MB 2988146 1 - 2 GB, with license code SD FLASH 2GB APPLIC A 2701190 1 - 512 MB, with license code SD FLASH 512MB APPLIC A 2701799 1 AX OPC SERVER, communication interface for OPC-compatible visualization with PC Worx-based controllers

AX OPC SERVER 2985945 1

532 PHOENIX CONTACT Controllers Compact controllers

device Compact controller Compact controller High-performance compact controller with remote bus support with two Ethernet ports with integrated floating-point arithmetic

 Ex:  

Technical data Technical data Technical data

) ILC 151 ETH1)ILC 151 ETH/XC1)

Inline data jumper Inline data jumper Inline data jumper RJ45 socket RJ45 socket RJ45 socket RS-232-C, 6-pos. MINI-DIN socket (PS/2), RS-232-C, 6-pos. MINI-DIN socket (PS/2), RS-232-C, 6-pos. MINI-DIN socket (PS/2), Ethernet 10/100 (RJ45) Ethernet 10/100 (RJ45) Ethernet 10/100 (RJ45)

max. 16 max. 24 max. 24 max. 4096 max. 4096 max. 4096 max. 128 max. 128 max. 128

88 8 44 4

Programmable under PC WorX in IEC 61131 PC WorX in IEC 61131 PC WorX in IEC 61131 PC WorX in IEC 61131 1.5 ms (1 K mix instructions) 1.5 ms (1 K mix instructions) 1.3 ms (1 K mix instructions) 90 µs (1 K bit instructions) 90 µs (1 K bit instructions) 90 µs (1 K bit instructions) Program memory 192 kbyte (16 K instructions (IL)) 256 kbyte (21 K instructions (IL)) 512 kbyte (43 K instructions (IL)) 1 Mbyte (86 K instructions (IL)) 256 kbyte 512 kbyte 1 Mbyte 8 kbyte (NVRAM) 48 kbyte (NVRAM) 48 kbyte (NVRAM) Number of data blocks (depends on data memory) (depends on data memory) (depends on data memory) (depends on data memory) Number of timers, counters (depends on data memory) (depends on data memory) (depends on data memory) (depends on data memory) 88 8 Yes Yes Yes

24 V DC 24 V DC 24 V DC 19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC 19.2 V DC ... 30 V DC 210 mA 210 mA 210 mA

80 mm 80 mm 80 mm 119.8 mm 119.8 mm 119.8 mm 71.5 mm 71.5 mm 71.5 mm IP20 IP20 IP20 Ambient temperature (operation) -25 °C ... 55 °C -40 °C ... 60 °C -25 °C ... 55 °C -40 °C ... 60 °C -25 °C ... 55 °C -25 °C ... 55 °C Ordering data Ordering data Ordering data

Pcs. / Pcs. / Pcs. / Type Order No. Type Order No. Type Order No. Pkt. Pkt. Pkt.

ILC 151 ETH1) 2700974 1 ILC 171 ETH 2TX 2700975 1 ILC 191 ETH 2TX 2700976 1 ILC 151 ETH/XC1) 2701141 1 Accessories Accessories Accessories

PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1

SD FLASH 256MB 2988120 1 SD FLASH 256MB 2988120 1 SD FLASH 2GB 2988162 1 SD FLASH 2GB 2988162 1 SD FLASH 2GB 2988162 1 SD FLASH 512MB 2988146 1 SD FLASH 512MB 2988146 1 SD FLASH 512MB 2988146 1 SD FLASH 2GB APPLIC A 2701190 1 SD FLASH 2GB APPLIC A 2701190 1 SD FLASH 2GB APPLIC A 2701190 1 SD FLASH 512MB APPLIC A 2701799 1 SD FLASH 512MB APPLIC A 2701799 1 SD FLASH 512MB APPLIC A 2701799 1

AX OPC SERVER 2985945 1 AX OPC SERVER 2985945 1 AX OPC SERVER 2985945 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 533 Controllers Compact controllers Class 100 controllers with integrated modem

These compact controllers offer all the functions of our 1x1 controllers. In addition, they have an integrated mo- bile phone modem and more memory. This makes them the ideal solution for remote control and remote maintenance. The corresponding remote control software is: Resy+.

Compact controller with integrated GSM/GPRS modem

Technical data Interfaces INTERBUS local bus (master) Inline data jumper Ethernet RJ45 socket Parameterization/operation/diagnostics Ethernet 10/100 (RJ45) INTERBUS master Number of possible parameter channels max. 16 Number of I/O nodes max. 4096 Number of supported devices max. 128 Direct I/Os Number of inputs 16 Number of outputs 4 IEC-61131 runtime system Programmable under PC WorX in IEC 61131 Processing speed 1.5 ms (1 K mix instructions) 90 µs (1 K bit instructions) Program memory 512 kbyte (43 K instructions (IL)) Data memory 512 kbyte Retentive data memory 48 kbyte (NVRAM) Number of data blocks (depends on data memory) Number of timers, counters (depends on data memory) Number of control tasks 8 Realtime clock Yes Power supply Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC Typical current consumption 210 mA General data Width 85 mm Height 119.8 mm Depth 71.5 mm Degree of protection IP20 Ambient temperature (operation) -25 °C ... 55 °C Ordering data

Pcs. / Description Type Order No. Pkt. Compact controller, complete with accessories (connector plug and marking field) ILC 151 GSM/GPRS 2700977 1 Accessories Parameterization memory, Flash card without license

- 2 GB SD FLASH 2GB 2988162 1 - 512 MB SD FLASH 512MB 2988146 1 - 2 GB, with license code SD FLASH 2GB APPLIC A 2701190 1 - 512 MB, with license code SD FLASH 512MB APPLIC A 2701799 1 Programming cable PRG CAB MINI DIN 2730611 1 AX OPC SERVER, communication interface for OPC-compatible visualization with PC Worx-based controllers

AX OPC SERVER 2985945 1

534 PHOENIX CONTACT Controllers Compact controllers Class 100 controllers for machine building

The ME versions of our compact control- lers have been specifically developed for the requirements of machine building. For ex- ample, for addressing drives via step motor drivers or frequency inverters. The compact controllers offer all the functions of the ILC 1x1 and come with pre- installed functions for machine building. This means that various drive types can be con- trolled and sensors can be connected with- Compact controller out any additional external modules. For easy drive control Depending on the version, analog or in- cremental input channels can be used for position detection. Technical data ILC 191 ME/AN ILC 191 ME/INC Interfaces INTERBUS local bus (master) Inline data jumper Ethernet RJ45 socket Parameterization/operation/diagnostics RS-232-C, 6-pos. MINI-DIN socket (PS/2), Ethernet 10/100 (RJ45) INTERBUS master Number of possible parameter channels max. 24 Number of I/O nodes max. 4096 Number of supported devices max. 128 Direct I/Os Number of inputs 8 Number of outputs 4 Analog inputs/outputs Number of inputs 2 - Number of outputs 2 - Counter inputs Number of inputs - 2 Input frequency - 200 kHz IEC-61131 runtime system Programmable under PC WorX in IEC 61131 Processing speed 1.3 ms (1 K mix instructions) 90 µs (1 K bit instructions) Program memory 1 Mbyte (86 K instructions (IL)) Data memory 1 Mbyte Retentive data memory 48 kbyte (NVRAM) Number of data blocks (depends on data memory) Number of timers, counters (depends on data memory) Number of control tasks 8 Realtime clock Yes Power supply Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC Typical current consumption 310 mA 350 mA General data Width 164 mm Height 119.8 mm Depth 71.5 mm Degree of protection IP20 Ambient temperature (operation) -25 °C ... 55 °C Ordering data

Pcs. / Description Type Order No. Pkt. Compact controller, complete with accessories (connector plug and marking field) - Analog inputs/outputs ILC 191 ME/AN 2700074 1 - Counter inputs ILC 191 ME/INC 2700075 1 Accessories Parameterization memory, Flash card without license

- 2 GB SD FLASH 2GB 2988162 1 - 512 MB SD FLASH 512MB 2988146 1 - 2 GB, with license code SD FLASH 2GB APPLIC A 2701190 1 - 512 MB, with license code SD FLASH 512MB APPLIC A 2701799 1 Programming cable PRG CAB MINI DIN 2730611 1 AX OPC SERVER, communication interface for OPC-compatible visualization with PC Worx-based controllers

AX OPC SERVER 2985945 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 535 Controllers Axiocontrol controllers Class 1000 controllers

The AXC 1050 Axiocontrol controllers are fast, robust, and user-friendly, i.e., they are all designed for maximum performance, easy handling, and use in harsh industrial en- vironments. Together with the Axioline I/O systems they form a high-performance, flexible, and particularly resistant automation system for every requirement. Thanks to the integrated UPS, you can re- Axiocontrol compact controller spond promptly to any voltage failures. Push-in connection technology simplifies wiring noticeably and also saves time. Your advantages: – Maximum flexibility - numerous I/Os and Technical data special function modules can be mounted AXC 1050 AXC 1050/XC Interfaces side by side AXIOBUS local bus Bus base module – Cost-effective solution, thanks to the ex- Ethernet RJ45 socket cellent price/performance ratio with high Parameterization/operation/diagnostics Micro USB type B AXIOBUS master function density Number of supported devices max. 63 – Optimum communication - with integrat- IEC-61131 runtime system ed, freely programmable web server for Programmable under PC WorX in IEC 61131 Processing speed 1.3 ms (1 K mix instructions) visualization with the WebVisit software 90 µs (1 K bit instructions) – Versatile use, as all common IT protocols Program memory 1 Mbyte Data memory 2 Mbyte are supported Retentive data memory 48 kbyte (NVRAM) Number of data blocks (depends on data memory) Additional features: Number of timers, counters (depends on data memory) – Continuous shock-resistant up to 10g Number of control tasks 16 – Increased EMC robustness Realtime clock Yes Power supply – Micro USB interface: for fast startup or Supply voltage 24 V DC changing the PLC settings without know- Supply voltage range 19.2 V DC ... 30 V DC Typical current consumption 125 mA ing the IP address General data – Modbus/TCP is integrated in the firmware Width 45 mm - this increases performance and simpli- Height 125.9 mm Depth 74 mm fies configuration. This makes communi- Degree of protection IP20 cation with other Modbus devices even Ambient temperature (operation) -25 °C ... 60 °C -40 °C ... 60 °C easier Ordering data – SD card slot: for quick memory expansion Pcs. / Description Type Order No. and easy enabling of software blocks Pkt. –FTP server Axiocontrol, complete with accessories (connector plug and – Flash file system marking field) – Complete Axiobus master AXC 1050 2700988 1 AXC 1050/XC 2701295 1 – Integration of IT standards such as FTP, HTTP, SNMP, SMTP, SQL, ODP, OPC, and Accessories many more Parameterization memory, Flash card without license – Intuitive programming using PC Worx or - 2 GB SD FLASH 2GB 2988162 1 using the free PC WORX EXPRESS soft- - 512 MB SD FLASH 512MB 2988146 1 - 2 GB, with license code SD FLASH 2GB APPLIC A 2701190 1 ware (IEC 61131-3) - 512 MB, with license code SD FLASH 512MB APPLIC A 2701799 1 – The XC versions are also suitable for Programming cable increased temperature requirements CAB-USB A/MICRO USB B/2,0M 2701626 1 (-40°C to +60°C)

536 PHOENIX CONTACT Controllers Axiocontrol controllers Class 3000 controllers

The AXC 3050 is the high-end controller in the Axiocontrol range. It offers all the EMC, shock, and vibration properties of the AXC 1050, as well as push-in connection technology and intelligent functions for so- phisticated automation. Thanks to the powerful processor and technology functions such as fast counters and event tasks, you can even implement complex applications reliably and efficiently. Axiocontrol high-performance controller Your advantages: – Highly flexible, thanks to expansion with numerous I/O modules – Communication in realtime via PROFINET Technical data – Optimum connection, with integrated Interfaces AXIOBUS local bus Bus base module web server and support for all common Ethernet RJ45 socket IT standards Parameterization/operation/diagnostics Micro USB type B – Maximum performance, thanks to high AXIOBUS master Number of supported devices max. 63 processor speed IEC-61131 runtime system Programmable under PC WorX in IEC 61131 Additional features: Processing speed 0.01 ms (1 K mix instructions) – Micro USB interface: for fast startup or Program memory 4 Mbyte changing the PLC settings without know- Data memory 8 Mbyte Retentive data memory 128 kbyte ing the IP address Number of data blocks (depends on data memory) – 3 integrated Ethernet interfaces for im- Number of timers, counters (depends on data memory) Number of control tasks 16 plementing different topologies Realtime clock Yes – Modbus/TCP is integrated in the firmware Power supply - this increases performance and simpli- Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC fies configuration. This makes communi- Typical current consumption 480 mA cation with other Modbus devices even General data easier Width 100 mm Height 125.9 mm – USB A interface for easy firmware update Depth 74 mm using a USB stick Degree of protection IP20 – Integrated web server for visualization Ambient temperature (operation) -25 °C ... 60 °C with WebVisit Ordering data

–FTP server Pcs. / Description Type Order No. – Flash file system Pkt. – Numerous protocols supported such as: Axiocontrol, complete with accessories (connector plug and marking field) HTTP, FTP, SNTP, SNMP, SMTP, SQL, AXC 3050 2700989 1 MySQL, etc. Accessories – Complete Axiobus master – Integrated PROFINET IO controller and Parameterization memory, Flash card without license integrated PROFINET IO device - 2 GB SD FLASH 2GB 2988162 1 - 512 MB SD FLASH 512MB 2988146 1 - 2 GB, with license code SD FLASH 2GB APPLIC A 2701190 1 - 512 MB, with license code SD FLASH 512MB APPLIC A 2701799 1 Programming cable CAB-USB A/MICRO USB B/2,0M 2701626 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 537 Controllers High-performance controllers

Class 300 controllers Notes: 1) EMC: Class A product, see page 553

Class 300 high-performance controllers can be used in complex applications where a high level of performance is required. Thanks to consistent PROFINET connec- tion and expansion with Inline I/O modules, the controllers are particularly flexible. Your advantages: – Highly flexible, thanks to expansion with numerous I/O modules High-performance controller – – Communication in realtime via basic device PROFINET – Optimum connection, with integrated web server and support for all common  IT standards Technical data Additional features: Interfaces – Integrated Ethernet interface INTERBUS (master) Inline data jumper – Integrated web server for visualization Higher-level INTERBUS (slave) - Ethernet RJ45 socket with WebVisit Parameterization/programming/diagnostics RS-232-C, 6-pos. MINI-DIN socket (PS/2), –FTP server Ethernet 10/100 (RJ45) – Flash file system INTERBUS master Number of possible parameter channels max. 62 – Numerous protocols supported such as: Number of I/O nodes max. 8192 HTTP, FTP, SNTP, SNMP, SMTP, SQL, Number of supported devices max. 512 (in total, of which 254 are remote bus devices/bus seg- ments) MySQL, etc. INTERBUS slave – Complete fieldbus master (8192 I/O Amount of process data - points) Direct I/Os Number of inputs 12 – Integrated PROFINET IO controller and Description of the input Eight fast inputs, interrupt input Eight fast inputs, interrupt input Eight fast inputs, interrupt input E integrated PROFINET IO device Number of outputs 4 IEC-61131 runtime system – Engineering with PC Worx (IEC 61131-3) Processing speed 0.7 ms (1 K mix instructions) 11 µs (1 K bit instructions) Program memory Typ. 750 kbyte (64 K instructions (IL)) Typ. 1 Mbyte (85 K instructions (IL)) Typ. 2 Mbyte (170 K instructions (IL) Data memory 1.5 Mbyte Retentive data memory 64 kbyte (NVRAM) Number of data blocks (depends on data memory) (depends on data memory) (depends on data memory) (depends on data memory) Number of timers, counters (depends on data memory) (depends on data memory) (depends on data memory) (depends on data memory) Number of control tasks 16 Realtime clock Integrated (battery backup) Integrated (battery Power supply Supply voltage 24 V DC ±5% Supply voltage range 20.4 V DC ... 30 V DC Typical current consumption 250 mA (no local bus device connected during idling, bus inactive) 250 mA (no local bus device connec

General data Width 182 mm Height 140.5 mm Depth 71.5 mm Degree of protection IP20 Ambient temperature (operation) -25 °C ... 55 °C Ordering data

Pcs. / Description Type Order No. Pkt. Inline controller, complete with accessories (connector and mark- ing field) and PROFINET I/O controllers

- PROFINET IO controller ILC 330 PN 2988191 1 - PROFINET IO controller, GL rating Accessories Parameterization memory - 256 MB CF FLASH 256MB 2988780 1 - 2 GB CF FLASH 2GB 2701185 1 Programming cable PRG CAB MINI DIN 2730611 1 AX OPC SERVER, communication interface for OPC-compatible visualization with PC Worx-based controllers

AX OPC SERVER 2985945 1

538 PHOENIX CONTACT Controllers High-performance controllers

High-performance controller High-performance controller Maximum performance high-performance with larger memory capacity with INTERBUS slave interface controller with INTERBUS slave interface

 Ex:  

Technical data Technical data Technical data

Inline data jumper Inline data jumper Inline data jumper - D-SUB-9 female/D-SUB-9 male D-SUB-9 female/D-SUB-9 male RJ45 socket RJ45 socket RJ45 socket RS-232-C, 6-pos. MINI-DIN socket (PS/2), RS-232-C, 6-pos. MINI-DIN socket (PS/2), RS-232-C, 6-pos. MINI-DIN socket (PS/2), Ethernet 10/100 (RJ45) Ethernet 10/100 (RJ45) Ethernet 10/100 (RJ45)

max. 62 max. 62 max. 62 max. 8192 max. 8192 max. 8192 max. 512 (in total, of which 254 are remote bus devices/bus seg- max. 512 (in total, of which 254 are remote bus devices/bus seg- max. 512 (in total, of which 254 are remote bus devices/bus seg- ments) ments) ments)

- 0...32 words (configurable) 0...32 words (configurable)

12 12 12 Description of the input Eight fast inputs, interrupt input Eight fast inputs, interrupt input Eight fast inputs, interrupt input Eight fast inputs, interrupt input 444

0.5 ms (1 K mix instructions) 0.3 ms (1 K mix instructions) 0.2 ms (1 K mix instructions) 9 µs (1 K bit instructions) 7 µs (1 K bit instructions) 6 µs (1 K bit instructions) Program memory Typ. 750 kbyte (64 K instructions (IL)) Typ. 1 Mbyte (85 K instructions (IL)) Typ. 2 Mbyte (170 K instructions (IL)) Typ. 2 Mbyte (170 K instructions (IL)) 2 Mbyte 4 Mbyte 4 Mbyte 64 kbyte (NVRAM) 96 kbyte (NVRAM) 96 kbyte (NVRAM) Number of data blocks (depends on data memory) (depends on data memory) (depends on data memory) (depends on data memory) Number of timers, counters (depends on data memory) (depends on data memory) (depends on data memory) (depends on data memory) 16 16 16 Realtime clock Integrated (battery backup) Integrated (battery backup) Integrated (battery backup) Integrated (battery backup)

24 V DC ±5% 24 V DC ±5% 24 V DC ±5% 20.4 V DC ... 30 V DC 20.4 V DC ... 30 V DC 20.4 V DC ... 30 V DC Typical current consumption 250 mA (no local bus device connected during idling, bus inactive) 250 mA (no local bus device connected during idling, bus inactive) 250 mA (no local bus device connected during idling, bus inactive) 250 mA (no local bus device connected during idling, bus inactive)

182 mm 182 mm 182 mm 140.5 mm 140.5 mm 140.5 mm 71.5 mm 71.5 mm 71.5 mm IP20 IP20 IP20 -25 °C ... 55 °C -25 °C ... 55 °C -25 °C ... 55 °C Ordering data Ordering data Ordering data

Pcs. / Pcs. / Pcs. / Type Order No. Type Order No. Type Order No. Pkt. Pkt. Pkt.

ILC 350 PN 2876928 1 ILC 370 PN 2TX-IB 2876915 1 ILC 390 PN 2TX-IB1) 2985314 1 ILC 370 PN 2TX-IB/M 2985576 1 Accessories Accessories Accessories

CF FLASH 256MB 2988780 1 CF FLASH 256MB 2988780 1 CF FLASH 256MB 2988780 1 CF FLASH 2GB 2701185 1 CF FLASH 2GB 2701185 1 CF FLASH 2GB 2701185 1

PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1 PRG CAB MINI DIN 2730611 1

AX OPC SERVER 2985945 1 AX OPC SERVER 2985945 1 AX OPC SERVER 2985945 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 539 Controllers High-performance controllers Class 400 controllers

More memory, more speed, more power. The class 400 PROFINET-compatible con- trollers are the most powerful embedded PLCs from Phoenix Contact. Control de- manding automation tasks with maximum performance and intelligent features. Your advantages: – Highly flexible, thanks to expansion with numerous I/O modules PLC, – Communication in realtime via with optional integrated safety controller PROFINET – Optimum connection, with integrated web server and support for all common  IT standards – Maximum performance, thanks to high Technical data processor speed Interfaces INTERBUS (master) D-SUB-9 socket Additional features: Ethernet 3x RJ45 sockets – Control and fieldbus system status mes- Parameterization/operation/diagnostics V.24 (RS-232-C), D-SUB plug, 10/100 Ethernet (RJ45), 2x USB sages are easily read via the diagnostics INTERBUS master display Number of possible parameter channels max. 126 Number of I/O nodes max. 8192 – Thanks to the powerful processor, com- Number of supported devices 512 (of which 254 are remote bus devices/bus segments) prehensive automation tasks can be pro- Direct I/Os cessed at maximum speed Connection method 14-pos. FLK pin strip – Integrated Ethernet interface Number of inputs 5 – Integrated web server for visualization Number of outputs 3 IEC-61131 runtime system with WebVisit Processing speed 0.005 ms (1 K mix instructions) –FTP server 1 µs (1 K bit instructions) Program memory Typ. 8 Mbyte (680 K instructions (IL)) – Flash file system Data memory 16 Mbyte – Numerous protocols supported such as: Retentive data memory 240 kbyte (NVRAM) HTTP, FTP, SNTP, SNMP, SMTP, SQL, Number of data blocks (depends on data memory) Number of timers, counters (depends on data memory) MySQL, etc. Number of control tasks 16 – Integrated INTERBUS master Realtime clock Integrated (battery backup) Power supply – Integrated PROFINET IO controller and Supply voltage 24 V DC PROFINET device Supply voltage range 19.2 V DC ... 30 V DC (including ripple) – Engineering with PC Worx (IEC 61131-3) Typical current consumption 1 A General data The safety version offers all the proper- Width 124 mm Height 185 mm ties of the RFC 470 PN controller and also Depth 190 mm has an integrated safety controller. This Degree of protection IP20 combination can be used to integrate safety Ambient temperature (operation) 0 °C ... 55 °C (from 45°C only with fan module) functions up to SIL 3 into existing systems. Ordering data The use of PROFIsafe reduces wiring ef- Pcs. / Description Type Order No. fort and installation time. Pkt.

Notes: Remote Field Controller with INTERBUS master

Further information on safety versions can be found in the - 3 x 10/100 Ethernet, PROFINET IO controller RFC 470 PN 3TX1) 2916600 1 “Functional safety” section on page 113 1) EMC: Class A product, see page 553 Safety controller RFC 470S PN 3TX1) 2916794 1 Accessories Parameterization memory - 256 MB CF FLASH 256MB 2988780 1 - 2 GB CF FLASH 2GB 2701185 1 Programming cable, to connect the controller boards to the PC (V.24 (RS-232-C)), length 3 m IBS PRG CAB 2806862 1 USB memory stick, USB 2.0 IP20 VS-04-MS-IP20 1402490 1 V.24 (RS-232) null modem adapter - 9-pos. socket to 9-pos. plug PSM-AD-D9-NULLMODEM 2708753 1 Fan module for Remote Field Controller RFC DUAL-FAN1) 2730239 1 AX OPC SERVER, communication interface for OPC-compatible visualization with PC Worx-based controllers

AX OPC SERVER 2985945 1

540 PHOENIX CONTACT Controllers High-performance controllers Class 400 controllers

Uninterrupted processes are vital in com- plex systems and large plants. Ensure the continuous operation of your automation - with the PROFINET redundancy controllers from Phoenix Contact. The high-performance PLCs establish a redundant system automatically thanks to AutoSync technology.

Your advantages: Redundancy PLC – Fast startup and automatic configuration of all redundancy functions, thanks to Au- toSync technology – Uninterrupted process in the event of fail-  ure or when a controller is replaced – Optimum device integration, thanks to Technical data PROFINET standards ; redundancy for Interfaces Ethernet 3x RJ45 sockets your future-proof Ethernet network Synchronization interface SFP port – A distance of up to 80 km between the Other interfaces 2 x USB controllers via fiber optics ; cost-opti- IEC-61131 runtime system Processing speed 0.007 ms (1 K mix instructions) mized thanks to plug-in SFP modules 2 µs (1 K bit instructions) – High-resolution display for displaying sta- Program memory Typ. 8 Mbyte (680 K instructions (IL)) Data memory 16 Mbyte tus and error messages in plain text Retentive data memory 120 kbyte (NVRAM) – Uninterrupted visualization - thanks to Number of data blocks (depends on data memory) redundancy-capable OPC server Number of timers, counters (depends on data memory) Number of control tasks 16 Notes: Realtime clock Integrated (battery backup) Power supply 1) EMC: Class A product, see page 553 Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (including ripple)

Typical current consumption 1 A General data Width 124 mm Height 185 mm Depth 190 mm Degree of protection IP20 Ambient temperature (operation) 0 °C ... 55 °C (from 45°C only with fan module) Ordering data

Pcs. / Description Type Order No. Pkt. High-availability remote field controller, thanks to redundancy function - 3 x 10/100 Ethernet, PROFINET IO controller RFC 460R PN 3TX1) 2700784 1

Accessories Parameterization memory - 256 MB CF FLASH 256MB 2988780 1 - 2 GB CF FLASH 2GB 2701185 1 USB memory stick, USB 2.0 IP20 VS-04-MS-IP20 1402490 1 Slot module for synchronization port - Distances of up to 550 m FL SFP SX 2891754 1 - Distances of up to 30 km FL SFP LX 2891767 1 - Distances of up to 80 km FL SFP LH 2989912 1 Synchronization cable for FL SFP SX - Length 1 m FL MM PATCH 1,0 LC-LC 2989158 1 - Length 2 m FL MM PATCH 2,0 LC-LC 2989255 1 - Length 5 m FL MM PATCH 5,0 LC-LC 2901799 1 Fan module for Remote Field Controller RFC DUAL-FAN1) 2730239 1 AX OPC SERVER, communication interface for OPC-compatible visualization with PC Worx-based controllers

AX OPC SERVER 2985945 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 541 Controllers Software PLC PC Worx SRT

PC Worx SRT is a software PLC that can be installed directly on a Windows PC. It only makes low demands on the PC hardware profile and can therefore be in- stalled on almost all Windows PCs. PC WORX SRT is therefore the ideal solu- tion for small to medium-sized automation tasks without realtime requirements. Programming is quick and easy using the PC Worx or PC Worx EXPRESS software. Software PLC without realtime extension Your advantages: – Save costs, as separate PLC hardware is not required – Easy and inexpensive visualization, thanks to integrated web server Technical data – Maximum Ethernet openness, as all com- Hardware requirements CPU x86 architecture mon protocols are supported Main memory (RAM) min. 512 Mbyte Hard disk memory min. 1 Gbyte Additional features: Optical drive - – Modbus/TCP is integrated in the firmware Interfaces Ethernet port - this increases performance and simpli- Operating equipment Keyboard, mouse recommended Monitor resolution XGA (1024 x 768) fies configuration. This makes communi- Software requirements cation with other Modbus devices even Operating systems MS Windows XP Professional SP3, MS Windows 7 (32/64-bit), MS Windows Embedded 2009, MS Windows Embedded Standard 7 easier. Basic functions – OPC support using AX OPC server Complete PLC –FTP server Non-realtime-capable software PLC for installation on a standard PC with integrated Modbus TCP, plus PROFINET IO controller and – Integrated PROFINET IO controller and device functionality PROFINET device IEC-61131 runtime system Programmable under PC WorX in IEC 61131 Processing speed (depends on PC processor and settings) Program memory 1 Mbyte Data memory 1 Mbyte Retentive data memory 48 kbyte Number of data blocks (depends on data memory) Number of timers, counters (depends on data memory) Number of control tasks 8 Ordering data

Pcs. / Description Type Order No. Pkt. Software PLC, without realtime extension PC Worx SRT 2701680 1 Accessories Industrial computer VALUELINE IPC 2913108 1 AX OPC SERVER, communication interface for OPC-compatible AX OPC SERVER 2985945 1 visualization with PC Worx-based controllers

542 PHOENIX CONTACT Controllers Software PLC

PC Worx RT BASIC Notes: 1) EMC: Class A product, see page 553

Make use of the available resources of your industrial PC and transform it into a fully-fledged PLC. The PC Worx RT BASIC software PLC system is as reliable and stable as a tradi- tional PLC and can be used in applications where a medium to high level of perfor- mance is required.

Your advantages: Software PLC – Save costs, as separate PLC hardware is with realtime extension not required – Stable and reliable, thanks to operating system extension – Easy and inexpensive visualization, thanks to integrated web server Technical data – Maximum Ethernet openness, as all com- Hardware requirements CPU INTEL Core2™ Duo 1.5 GHz recommended mon protocols are supported Main memory (RAM) min. 2 Gbyte Hard disk memory min. 1 Gbyte Additional features: Optical drive DVD-ROM – Optimally integrated into the PROFINET Interfaces Ethernet port, USB port system Operating equipment Keyboard, mouse recommended Monitor resolution XGA (1024 x 768) – Easy installation on Valueline industrial Software requirements PCs Operating systems MS Windows XP SP3, MS Windows 7 (32 bit) – Modbus/TCP is integrated in the firmware Supported browsers Internet Explorer 5.5 or higher Basic functions - this increases performance and simpli- Complete PLC fies configuration. This makes communi- PROFINET IO controller and device functionality only in conjunction with a Valueline PC cation with other Modbus devices even INTERBUS functionality only in conjunction with an INTERBUS easier master controller board IEC-61131 runtime system – OPC support using AX OPC server Programmable under PC WorX in IEC 61131 –FTP server Processing speed 0.001 ms (1 K mixed instructions, Core2™ Duo 1.5 GHz) – Numerous protocols supported such as: 0.7 µs (1 K bit instructions, Core2™ Duo 1.5 GHz) HTTP, FTP, SNTP, SNMP, SMTP, SQL, Program memory 8 Mbyte MySQL, etc. Data memory 16 Mbyte Retentive data memory 240 kbyte – Integrated PROFINET IO controller and Number of data blocks (depends on data memory) PROFINET device Number of timers, counters (Depends on data memory) – INTERBUS connection via PC controller Number of control tasks 16 board Ordering data

– Engineering with PC Worx (IEC 61131-3) Pcs. / Description Type Order No. Pkt. Software PLC, with realtime extension PC Worx RT BASIC 2700291 1 Accessories Industrial computer VALUELINE IPC 2913108 1 PC controller board IBS PCI SC/I-T1) 2725260 1 AX OPC SERVER, communication interface for OPC-compatible AX OPC SERVER 2985945 1 visualization with PC Worx-based controllers

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 543 Controllers Starter kits ILC 131 starter kit

The ILC 131 starter kit provides an easy introduction to our controllers. Learn about control technology with the aid of a pre-assembled test structure with pro- grammed examples. Then use the PC WORX EXPRESS programming soft- ware to create custom solutions. Begin by starting up the controller, config- uring it, and parameterizing the bus struc- ture. With the test structure, enter the Pre-assembled test structure for quick entry world of IEC 61131-3-compliant program- ming. Controller performance data at a glance: – Supply voltage: 24 V DC Technical data – Integrated inputs /outputs: 8 / 4 See ILC 131 ETH on page 532 – Processing time per 1000 instructions: 90 μs (bit data types), 1.7 ms (mixed data Ordering data types) Pcs. / – Program / data memory: 192 kB / 192 kB Description Type Order No. – Remanent data memory: 8 kB Pkt. ILC 131 starter kit, incl. ILC 131 ETH, analog input module, con- trol panel, power supply unit, plus accessories and cables with test application set up

ILC 131 STARTERKIT 2701835 1 Accessories Programming cable PRG CAB MINI DIN 2730611 1 AX OPC SERVER, communication interface for OPC-compatible visualization with PC Worx-based controllers

AX OPC SERVER 2985945 1

544 PHOENIX CONTACT Controllers Starter kits PROFINET starter kit

Try out the reliable operation, easy han- dling, and high performance of PROFINET. With the new PROFINET starter kit 3.0, Phoenix Contact provides a system with all the necessary components for creating a test application. In order to provide a quick and easy intro- duction, we have created a pre-configured project based on the current version of our PC Worx software. PROFINET starter kit Controller performance data at a glance: – Supply voltage: 24 V DC –Integrated I/Os: 12/4 – Operating time per 1000 instructions: Technical data 0.5 ms See ILC 350 PN on page 539 – Program/data memory: 1 MB/2 MB – Retentive data memory: 64 KB Ordering data

Pcs. / Description Type Order No. Pkt. PROFINET starter kit 3.0, includes a PROFINET IO controller, bus terminal modules, I/O modules, managed switch, power supply unit, plus accessories and cables for creating a PROFINET test application. An example project and PC Worx 6 license key are also included. PROFINET STARTERKIT 3.0 2988395 1 Accessories AX OPC SERVER, communication interface for OPC-compatible visualization with PC Worx-based controllers

AX OPC SERVER 2985945 1

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 545 Controllers Services for automation

Whatever your automation task: our Your advantages: Services for functional safety specialists in the AUTOMATIONWORX – Save time by transferring automation can be found on page 114. Competence Center are available to answer tasks to Phoenix Contact any questions you may have. This is made – Optimum automation solution thanks to Services for comprehensive technology and product possible by our flexible service concept. can be found on page 46. expertise Based on the typical phases of a project, – Sophisticated process management we work with you at each stage. With our thanks to the consistent consideration of expertise and years of experience we pro- all requirements vide support that is tailored to your indus- – Target-oriented project management try and the specific phase of your project. with optimally coordinated process steps – Traceable, legal protection thanks to con- sistent documentation

546 PHOENIX CONTACT Controllers Services for automation

Service Training Engineering You can rely on our support for the Discover the added value our individual Whatever your automation task: our en- smooth operation of your application. Our training concepts and training services offer. gineering specialists are available to answer experts deal with queries encountered in With our tailor-made concepts, we help any questions you may have. Based on the practical applications every day. They draw you and your employees to make optimum typical phases of a project, we work with on their experience of all sectors and use of the control and I/O systems from you at each stage. knowledge of the components and technol- Phoenix Contact. With our expertise and years of experi- ogies used. ence we provide support that is tailored to With our free consultation service, you your industry and the specific phase of your Our service specialists will be happy to can arrange the content, duration, location, project. support you with the following services: and date of your individual training session – Hotline with us. Simply give us an outline of the applica- – On-site service tions you would like to implement and we – Startup support Should you have any queries regarding our will provide you with a technical concept – Professional workshops training services and qualification concepts, that includes suitable hardware and soft- please contact your local contact person or ware. If queries arise during startup and contact our Back Office Training team di- – Configuration operation, in addition to your local rectly (+ 49 5281 9-462161 or e-mail us on –Programming specialists you can also contact our [email protected]). –Visualization free 24-hour hotline at any time We will happily advise you on the imple- –Coaching (+ 49 5281 9-462888) or e-mail us on mentation of your qualification require- [email protected]. ments and work with you to create your If queries arise in the run-up to or during We will be happy to answer general ques- own individual training program. a project, in addition to your local specialists tions regarding the functionality of individu- you can also contact us at any time on al components or the system. If this is not + 49 5281 9-462166 or e-mail us on sufficient, our startup support team and on- [email protected]. site service will be there to provide assis- tance.

For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 547