Sterilization Wrapping System

Total Page:16

File Type:pdf, Size:1020Kb

Sterilization Wrapping System Pharmaceutical/Industrial Catalog Dec-13 Metric Version STERILIZATION WRAPPING SYSTEM Ò Media Bottle, Flask and Pipe Closures - Tyvek or Heavy-Duty Blue Wrapper, Autoclavable, with Elastic, “Autoclavable Mini-Muffs” Description (cm) Fits Opening Size of: Reorder No. Material - add to Reorder No. Case (cm) (e.g. 1033TW) Pack TyvekÒ, White Heavy-Duty TW Blue B 8 diameter (XXS) 1.5 to 3 diameter 1033 · 1000 10 diameter (XS) 4 to 4.5 diameter 1034 · · 1000 13 diameter (S) 4.5 to 6.5 diameter 1035 · · 1000 18 diameter (M) 6.5 to 10 diameter 1037 · · 1000 23 diameter (L) 10 to 14 diameter 1039 · · 1000 31 diameter (XL) 14 to 20 diameter 10312 · · 1000 41 dia. (XXL) 20 to 31 diameter 10316 · · 500 Note: Add TD for drawstring bottom. Ò Stopper Bowl Covers - Tyvek , Autoclavable, with Elastic Description (cm) Fits Bowl Size of: (cm) Reorder No. Case Pack 61 diameter 31 to 51 diameter 024TW 500 76 diameter 51 to 66 diameter 030TW 500 91 diameter 66 to 76 diameter 036TW 100 122 diameter 76 to 102 diameter 048TW 50 Note: Add TD for drawstring bottom. Ò Steam Component Bags - Tyvek , Autoclavable, Heat Seal Description (cm) Reorder No. Case Description (cm) Reorder No. Case Pack Pack 24 x 31 6000TW 250 41 x 61 6002TW 250 25 x 38 6059TW 250 46 x 76 6003TW 250 25 x 76 6006TW 250 51 x 102 6004TW 250 31 x 31 61212TW 250 61 x 61 6008TW 250 31 x 41 61216TW 250 61 x 91 6005TW 250 31 x 46 61218TW 250 91 x 91 63636TW 250 36 x 46 6001TW 250 122 x 122 64848TW 125 Ò Tyvek Tubing, Lint-free, 152 meters , Autoclavable, Heat Seal Description (cm) Reorder No. Case Description (cm) Reorder No. Case Pack Pack 5 wide 60002TW 152* 25 wide 60100TW 152* 8 wide 60003TW 152* 31 wide 60120TW 152* 10 wide 60004TW 152* 38 wide 60150TW 152* 13 wide 60005TW 152* 61 wide 60240TW 152* 15 wide 60006TW 152* 76 wide 60300TW 152* 20 wide 60008TW 152* 102 wide 60400TW 152* *Meters *Meters Need a product that is not listed? Need a size, style or material that you cannot find? Contact General Econopak, Inc. and we will accommodate your request. Tel : +1-215-763-8200 ● Email: [email protected] 1 Pharmaceutical/Industrial Catalog Dec-13 Metric Version Ò Pharma Wrappers, Tyvek , Lint-free, Autoclavable Description (cm) Reorder No. Case Pack 19 x 19 759TW 1000 38 x 38 760TW 1000 51 x 51 762TW 1000 61 x 61 765TW 1000 76 x 76 761TW 1000 102 x 102 764TW 500 Ò Stopper Bags, Tyvek / Polyethylene Film, Autoclavable, Heat Seal, with Sterilization Indicator Description (cm) Reorder No. Case Description (cm) Reorder No. Case Pack Pack 8 x 10 0304SBSD 1000 33 x 46 1318SBSD 500 8 x 15 0306SBSD 1000 36 x 36 1414SBSD 500 10 x 23 0409SBSD 500 41 x 49 1518SBSD 500 10 x 56 0422SBSD 500 41 x 41 1616SBSD 500 13 x 20 0508SBSD 500 41 x 81 1632SBSD 250 16 x 25 0610SBSD 500 46 x 61 1824SBSD 500 16 x 76 0630SBSD 500 50 x 56 1920SBSD 500 20 x 31 0812SBSD 500 56 x 41 2216SBSD 500 25 x 89 1035SBSD 500 54 x 62 2022SBSD 500 31 x 31 1212SBSD 500 53 x 71 2026SBSD 250 31 x 38 1215SBSD 500 61 x 91 2436SBSD 250 33 x 53 1219SBSD 500 71 x 122 2848SBSD 125 31 x 97 1238SBSD 500 Ò Stopper Tubing, Tyvek / Polyethylene Film, Autoclavable, Heat Seal Description (cm) Reorder No. Case Description (cm) Reorder No. Case Pack Pack 5 wide 002SBT 152* 26 wide 010SBT 152* 8 wide 003SBT 152* 30 wide 012SBT 152* 10 wide 004SBT 152* 46 wide 018SBT 152* 15 wide 006SBT 152* 71 wide 028SBT 76* 23 wide 009SBT 152* *Meters *Meters Need a product that is not listed? Need a size, style or material that you cannot find? Contact General Econopak, Inc. and we will accommodate your request. Tel : +1-215-763-8200 ● Email: [email protected] 2 Pharmaceutical/Industrial Catalog Dec-13 Metric Version Ò Breather Bags – Self Seal, Tyvek / Polyester Film, Autoclavable, with Sterilization Indicator Description Reorder No. Case Description Reorder No. Case (cm) Pack (cm) Pack 5 x 17 00206TWBBSSSD 1000 20 x 86 00834TWBBSSSD 500 5 x 23 00209TWBBSSSD 1000 26 x 28 01011TWBBSSSD 500 8 x 15 00306TWBBSSSD 1000 26 x 50 01020TWBBSSSD 500 8 x 20 X0308TWBBSSSD 500 31 x 36 01214TWBBSSSD 500 9 x 20 00308TWBBSSSD 500 31 x 43 01217TWBBSSSD 500 10 x 38 00415TWBBSSSD 500 36 x 61 01424TWBBSSSD 500 10 x 56 00422TWBBSSSD 500 38 x 50 01520TWBBSSSD 500 13 x 25 00510TWBBSSSD 500 41 x 43 01617TWBBSSSD 500 16 x 20 00608TWBBSSSD 500 41 x 66 01626TWBBSSSD 500 15 x 31 00612TWBBSSSD 500 41 x 81 01632TWBBSSSD 250 15 x 71 00628TWBBSSSD 500 41 x 89 01635TWBBSSSD 250 15 x 81 00632TWBBSSSD 500 46 x 56 01822TWBBSSSD 500 18 x 33 00713TWBBSSSD 500 61 x 66 02426TWBBSSSD 250 20 x 26 00810TWBBSSSD 500 61 x 76 02430TWBBSSSD 250 20 x 38 00815TWBBSSSD 500 61 x 89 02435TWBBSSSD 250 20 x 46 00818TWBBSSSD 500 Ò Breather Bags – Heat Seal, Tyvek / Polyester Film, Autoclavable, with Sterilization Indicator Description Reorder No. Case Description Reorder No. Case (cm) Pack (cm) Pack 8 x 15 00306TWBBSD 1000 31 x 44 01217TWBBSD 500 15 x 20 00608TWBBSD 500 31 x 46 01218TWBBSD 500 15 x 31 00612TWBBSD 500 32 x 61 01224TWBBSD 500 20 x 25 00810TWBBSD 500 41 x 43 01617TWBBSD 500 20 x 39 00815TWBBSD 500 47 x 56 01822TWBBSD 500 25 x 51 01020TWBBSD 500 61 x 46 02418TWBBSD 500 25 x 76 01030TWBBSD 500 61 x 61 02424TWBBSD 500 31 x 31 01212TWBBSD 500 61 x 76 02430TWBBSD 500 Ò Breather Tubing, Tyvek / Polyester Film, Autoclavable, Heat Seal Description (cm) Reorder No. Case Description (cm) Reorder No. Case Pack Pack 10 wide 004TWBBT 152* 36 wide 014TWBBT 152* 15 wide 006TWBBT 152* 46 wide 018TWBBT 152* 23 wide 009TWBBT 152* 61 wide 024TWBBT 152* 31 wide 012TWBBT 152* *Meters *Meters Need a product that is not listed? Need a size, style or material that you cannot find? Contact General Econopak, Inc. and we will accommodate your request. Tel : +1-215-763-8200 ● Email: [email protected] 3 Pharmaceutical/Industrial Catalog Dec-13 Metric Version Sterilization Pouches, Kraft Paper/Polyester Film, Autoclavable, Self Seal with Indicators Description (cm) Reorder No. Case Pack 9 x 23 026 1000 9 x 57 027 1000 13 x 26 028 1000 19 x 34 029 1000 31 x 39 030 500 Sterilization Pouches, Kraft Paper/Polyester Film, Autoclavable, Heat Seal with Indicators Description (cm) Reorder No. Case GUSSETED Pack Description (cm) Reorder No. Case 10 x 20 003 1000 Pack 13 x 25 004 1000 13 x 25 x 5 021 1000 19 x 33 005 1000 23 x 36 x 10 022 500 31 x 38 006 500 31 x 56 x 15 023 500 Sterilization Tubing, Kraft Paper/Polyester Film, Autoclavable, Heat Seal, 30.5 meters per roll Description (cm) Reorder No. Case Pack 5 wide 032 10* 8 wide 033 10* 10 wide 034 10* 15 wide 036 10* 23 wide 039 6* 31 wide 042 6* *Rolls Sterilization Wrappers, Heavy-Duty Blue, Autoclavable Description (cm) Reorder No. Case Description (cm) Reorder No. Case Pack Pack 31 x 31 1029BHD 1000 91 x 91 1035BHD 250 38 x 38 1030BHD 1000 102 x 102 1038BHD 250 46 x 46 1031BHD 1000 112 x 112 1037BHD 250 51 x 51 1032BHD 1000 137 x 137 1039BHD 100 61 x 61 1033BHD 250 137 x 183 1072BHD 100 76 x 76 1034BHD 250 152 x 203 1040BHD 50 Need a product that is not listed? Need a size, style or material that you cannot find? Contact General Econopak, Inc. and we will accommodate your request. Tel : +1-215-763-8200 ● Email: [email protected] 4 Pharmaceutical/Industrial Catalog Dec-13 Metric Version Ò Sealing Tape, Tyvek , Autoclavable Description Reorder No. Case Pack TyvekÒ, White, 8 cm x 320 m rolls 008138TWR 2 Sterility Maintenance Covers, Polyethylene, Packaged STERILE – 1 per Pack HEAT SEAL SELF SEAL Description (cm) Reorder No. Case Description (cm) Reorder No. Case Pack Pack 20 x 31 3212ST 500 20 x 31 3312ST 500 25 x 38 3215ST 500 25 x 38 3315ST 500 31 x 51 3220ST 500 31 x 51 3320ST 500 41 x 56 3222ST 250 41 x 56 3322ST 250 41 x 76 3230ST 250 41 x 76 3330ST 250 61 x 76 3234ST 250 61 x 76 3334ST 250 Also available in 2, 5 or 10 packs. 64 x 94 3335ST 250 Also available in 2, 5 or 10 packs. Need a product that is not listed? Need a size, style or material that you cannot find? Contact General Econopak, Inc. and we will accommodate your request. Tel : +1-215-763-8200 ● Email: [email protected] 5 Pharmaceutical/Industrial Catalog Dec-13 Metric Version COVERS, CLOSURES, TRANSFER SLEEVES Covers: Equipment, Mills, Presses, Coaters, Dryers, etc. Description Reorder No. Material - add to Reorder No. (e.g. 484860TW) Case TyvekÒ, White TyvekÒ, GMP Print Pack TW TGMP Equipment, Large 484860 · · 50 Equipment, Small 423460 · · 50 Mill, Large 607860 · · 50 Mill, Small 604444 · · 50 Tablet Press 605060 · · 50 Coater/Dryer 444460 · · 50 MANY OTHER STANDARD SIZES AVAILABLE. Note: Add suffix EL for elastic bottom, TD for drawstring bottom, S1 for side snap closure. Covers: Racks, Carts Description Reorder No. Material - add to Reorder No. (e.g. 603072TW) Case TyvekÒ, White TyvekÒ, GMP Print Pack TW TGMP Rack/Cart, Large 603072 · · 50 Rack/Cart, Small 482430 · · 50 MANY OTHER STANDARD SIZES AVAILABLE.
Recommended publications
  • The Example of Closure Systems for Bottled Wine
    Sustainability 2012, 4, 2673-2706; doi:10.3390/su4102673 OPEN ACCESS sustainability ISSN 2071-1050 www.mdpi.com/journal/sustainability Article The Importance of Considering Product Loss Rates in Life Cycle Assessment: The Example of Closure Systems for Bottled Wine Anna Kounina 1,2,*, Elisa Tatti 1, Sebastien Humbert 1, Richard Pfister 3, Amanda Pike 4, Jean-François Ménard 5, Yves Loerincik 1 and Olivier Jolliet 1 1 Quantis, Parc Scientifique EPFL, Bâtiment D, 1015 Lausanne, Switzerland; E-Mails: [email protected] (E.T.); [email protected] (S.H.); [email protected] (Y.L.); [email protected] (O.J.) 2 Swiss Federal Institute of Technology Lausanne (EPFL), 1015 Lausanne, Switzerland 3 Praxis Energia, rue Verte, 1261 Le Vaud, Switzerland; E-Mail: [email protected] 4 Quantis, 283 Franklin St. Floor 2, Boston, MA 02110, USA; E-Mail: [email protected] 5 Quantis, 395 rue Laurier Ouest, Montréal, Québec, H2V 2K3, Canada; E-Mail: [email protected] * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +41-21-693-91-95; Fax: +41-21-693-91-96. Received: 23 July 2012; in revised form: 21 September 2012 / Accepted: 2 October 2012 / Published: 18 October 2012 Abstract: Purpose: The objective of this study is to discuss the implications of product loss rates in terms of the environmental performance of bottled wine. Wine loss refers to loss occurring when the consumer does not consume the wine contained in the bottle and disposes of it because of taste alteration, which is caused by inadequate product protection rendering the wine unpalatable to a knowledgeable consumer.
    [Show full text]
  • Glass Container Styles
    Glass Container Styles Glass Bottles & Jars Boston Round Bottles Boston Round Bottles are general use bottles that are perfect for liquids, product storage, and field or plant sampling projects. They feature a round body, rounded shoulders and narrow screw neck opening. These environmentally sensitive bottles help eliminate waste and help to ensure product integrity for long term storage. Clear / Flint Boston Round Bottles offers maximum visibility and sample integrity. Amber & Cobalt Blue Boston Round Bottles protect contents from UV rays and are ideal for light sensitive products. Composite Test Jars Clear / Flint Composite Test Jars are clear wide-mouth straight sided jars that are ideal for sampling and provide maximum content visibility. These bottles are designed without shoulders for maximum storage capacity. French Square Bottles Clear / Flint French Square Bottles provide maximum content visibility. The space saving design saves on shelf and storage space. The wide mouth opening is ideal for mixing, storing and sampling. Graduated Medium Round Bottles Bottle Beakers® also known as Graduated Medium Rounds are excellent for use with biological and pathological specimens, but can also be used for storing industrial laboratory chemicals and reagents. These clear / flint bottles are designed with a slight shoulder for easy pouring and handling. Graduated in ml and ounces. Mix, measure, and store in the same container. Media Bottles Media Bottles are manufactured from PYREX® borosilicate glass for chemical and thermal resistance and can be used for storage as well as mixing and sampling. Regular Media Bottles have permanent white enamel graduations and marking spots. PYREXPlus® Media Bottles have a protective PVC coating helps prevent glass from shattering and reduces spills.
    [Show full text]
  • Laboratory Supplies and Equipment
    Laboratory Supplies and Equipment Beakers: 9 - 12 • Beakers with Handles • Printed Square Ratio Beakers • Griffin Style Molded Beakers • Tapered PP, PMP & PTFE Beakers • Heatable PTFE Beakers Bottles: 17 - 32 • Plastic Laboratory Bottles • Rectangular & Square Bottles Heatable PTFE Beakers Page 12 • Tamper Evident Plastic Bottles • Concertina Collapsible Bottle • Plastic Dispensing Bottles NEW Straight-Side Containers • Plastic Wash Bottles PETE with White PP Closures • PTFE Bottle Pourers Page 39 Containers: 38 - 42 • Screw Cap Plastic Jars & Containers • Snap Cap Plastic Jars & Containers • Hinged Lid Plastic Containers • Dispensing Plastic Containers • Graduated Plastic Containers • Disposable Plastic Containers Cylinders: 45 - 48 • Clear Plastic Cylinder, PMP • Translucent Plastic Cylinder, PP • Short Form Plastic Cylinder, PP • Four Liter Plastic Cylinder, PP NEW Polycarbonate Graduated Bottles with PP Closures Page 21 • Certified Plastic Cylinder, PMP • Hydrometer Jar, PP • Conical Shape Plastic Cylinder, PP Disposal Boxes: 54 - 55 • Bio-bin Waste Disposal Containers • Glass Disposal Boxes • Burn-upTM Bins • Plastic Recycling Boxes • Non-Hazardous Disposal Boxes Printed Cylinders Page 47 Drying Racks: 55 - 56 • Kartell Plastic Drying Rack, High Impact PS • Dynalon Mega-Peg Plastic Drying Rack • Azlon Epoxy Coated Drying Rack • Plastic Draining Baskets • Custom Size Drying Racks Available Burn-upTM Bins Page 54 Dynalon® Labware Table of Contents and Introduction ® Dynalon Labware, a leading wholesaler of plastic lab supplies throughout
    [Show full text]
  • Carbopol Pemulen Or Noveon Loss on Drying Test Procedure
    LUBRIZOL TEST PROCEDURE Test Procedure SA-004 Edition: August, 2010 Loss on Drying Applicable Products: Carbopol®* Polymers, Pemulen™* Polymeric Emulsifiers and Noveon®* AA-1 Polycarbophil Scope: Apparatus: This procedure is for the determination of 1. Vacuum oven controlled at 80 ± 2°C (176 ± volatile materials in Carbopol® polymers, 4°F) with a vacuum of 29 inches (736 mm) Hg. ® Pemulen™ polymeric emulsifiers and Noveon 2. Vacuum oven controlled at 45 ± 2°C (113 ± AA-1 polycarbophil. 4°F) with a vacuum of 29 inches (736 mm) Hg. 3. Balance capable of ±0.0001 g accuracy. Abstract: 4. Heat safe weighing bottle with glass stopper. A weighed sample of polymer is placed in a 5. Desiccator with silica gel desiccant. vacuum oven at a vacuum of 29 inches (736 mm) 6. Vacuum pump. Hg at the specified temperature and time. The sample is cooled, reweighed and the percent weight loss calculated. Safety Precautions: 1. Wear safety goggles and gloves. 2. Polymer dust is irritating to the respiratory passages and inhalation should be avoided. 3. See all Material Safety Data Sheets (MSDS) for additional safety and handling information. Interferences: Care must be taken to avoid moisture pick-up from the atmosphere. The most accurate measurements can be expected from samples removed the first time the sample container is opened. Because of the hygroscopic nature of Carbopol® polymers, Pemulen™ polymeric emulsifiers and Noveon® AA-1 polycarbophil, moisture pick-up each time the sample container is opened will influence the loss on drying. Lubrizol Advanced Materials, Inc. / 9911 Brecksville Road, Cleveland, Ohio 44141-3247 / TEL: 800.379.5389 or 216.447.5000 The information contained herein is believed to be equipment used commercially in processing these Materials, Inc.’s direct control.
    [Show full text]
  • Bottlesinsmall Case for Unlimitedapplications
    BOTTLES KIMAX® media bottles are the perfect bottle for any application. The outstanding quality ensures a wide range of use, from long term storage and transporting to the most demanding applications in the pharmaceutical and food industries. Sturdy design and improved clarity allow contents and volume to be checked quickly, while temperature resistance makes the bottles ideal for autoclaving. Essential to every laboratory, KIMAX® media bottles are proven reliable for unlimited applications. We offer a wide variety of general purpose bottles in small case quantities or large bulk packs with a variety of closures. We also offer containers with or without caps attached for high use items or facilities with centralized stockrooms. Customization to meet your specific needs is simpler than ever, including pre-cleaning and barcoding. Trust DWK Life Sciences to be the exclusive source for all your laboratory glass needs. DWK Life Sciences 22 BOTTLES Clear Glass Boston Round / Amber Glass Boston Round Clear Glass Boston Round Bottles Amber Glass Boston Round Bottles Kimble® Clear Boston Rounds are made from Type III Kimble® Amber Boston Rounds are made from Type III soda-lime glass and have a narrow-mouth design. Clear soda-lime glass and have a narrow-mouth design. Amber bottles allow for viewing of contents. They come with a bottles protect light-sensitive contents. They come with a variety of caps and liner combinations and are designed variety of caps and liner combinations. They are designed to protect the quality of liquids and product storage. to protect contents from UV rays and are ideal for light- sensitive products.
    [Show full text]
  • Jan. 3, 1967 H. C. A. EVERS ETAL 3,295,525 SELF-ASPIRATING CARTRIDGE AMPOULE Filed April 7, 1964
    Jan. 3, 1967 H. C. A. EVERS ETAL 3,295,525 SELF-ASPIRATING CARTRIDGE AMPOULE Filed April 7, 1964 K. K. a/1a/yapas M24/VS 6as Zaat 176ao A227as sp12.1/ 12476a 2/774/// attazá3. 1772a Mays 3,295,525 United States Patent Office Patented Jan. 3, 1967 1. 2 the interior of the ampoule, includes the elastic mem 3,295,525 brane and is substantially plane. SELF-ASPERATING CARTRIDGE AMPOULE The reason why the bubble gets easily loose from the Hans Christer Arvid Evers and Sven Paul Littorin, Soder talje, Sweden, assignors to Aktiebolaget Astra, Apote plunger is probably that there is no narrow pocket in karnes Kemiska Fabriker, Sodertalje, Sweden, a com the plunger, and that bubbles are probably more inclined pany of Sweden to adhering to a rubber surface than to a glass surface. Filed Apr. 7, 1964, Ser. No. 358,034 As is well known bubbles have a tendency for gathering Claims priority, application Sweden, Apr. 9, 1963, in "concave corners.” In the known plunger there is a 3,975/63 concave corner defined by two rubber walls, whereas the 1 Claim. (C. 128-272) 10 plunger of the present invention has a concave corner defined by a rubber wall and a glass wall. This invention relates to a self-aspirating cartridge The invention will now be more fully disclosed with ampoule of the known type in which the aspiration is reference to the accompanying drawing which illustrates produced by a particular shape of the rubber stopper an embodiment of a cartridge ampoule of the invention.
    [Show full text]
  • Basic Considerations for Container Closure Selection of Parenteral Drug Products Lakshmi Prasanna Kolluru*
    A tica nal eu yt c ic a a m A r a c t h a P Kolluru, Pharm Anal Acta 2017, 8:5 Pharmaceutica Analytica Acta DOI: 10.4172/2153-2435.1000e189 ISSN: 2153-2435 Editorial Open Access Basic Considerations for Container Closure Selection of Parenteral Drug Products Lakshmi Prasanna Kolluru* Medefil Inc, Glendale Heights, IL 60139, USA. *Corresponding author: Lakshmi Prasanna Kolluru, Sr. Formulation Scientist, Medefil Inc., 250/405 Windy Point Drive, Glendale Heights, IL 60139, USA, Tel: +1-630-682-4600; Email: [email protected] Received date: May 02, 2017; Accepted date: May 10, 2017; Published date: May 16, 2017 Copyright: © 2017 Kolluru LP. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Editorial usage of RTU components can aid in reducing the risk on contamination of the drug product [4]. By definition, container closure system encompasses all components of the packaging system that hold and protect the drug product. It Intended use includes primary packaging system (components with which the drug product comes in direct contact) and secondary packaging system Container-closure selection varies for liquid and lyophilized drug (components that offer additional protection to the system but do not products. Traditionally, tubular vials are preferred over molded vials come in direct contact with the drug product). This article focuses on during lyophilization because of the flat bottom of vials that help in primary packaging components as they have a significant effect on the uniform heat transfer from the freeze drying shelves to the drug critical quality attributes of the drug product throughout the product product.
    [Show full text]
  • Parts Catalog 10 03.P65
    TupperwareItem # Mold # DescriptionParts Catalog Credit Value Suggested Retail Item # Mold # Description Credit Value Suggested Retail 2440 ................. 13 .................... Paddle Scraper/Spatula ...................................................... 0.49 .............................. 0.98 OBS ................. 39/40 ............... Soap Case .......................................................................... 0.35 OBS ................. 52/55 ............... Bye Fly Swatter ................................................................... 0.49 OBS ................. 61 .................... Curl Comb ........................................................................... 0.29 OBS ................. 62 .................... Purse Comb ........................................................................ 0.29 OBS ................. 63 .................... Pocket Comb ...................................................................... 0.46 OBS ................. 64 .................... Man’s Dresser Comb .......................................................... 0.55 OBS ................. 93 .................... Nursery Tray ....................................................................... 0.74 OBS ................. 101 .................. 2-oz. Midgets® cont. C.S. see # 4789 .............................. 1.07 OBS ................. 102 .................. Spice Shaker see #1843, #1844 ........................................ 0.73 OBS ................. 107 .................. 16-oz Tumbler see #3515 ..................................................
    [Show full text]
  • INSTRUCTIONS for USE It
    INSTRUCTIONS FOR USE it. Do not use it if the liquid is discolored or contains any lumps or large particles in it. STRENSIQ® [stren' sik] Throw it away and get a new (asfotase alfa) vial. injection, for subcutaneous use Step 2: Using your thumb, flip the vial plastic cap off the STRENSIQ vial. Read this “Instructions for Use” before you start using STRENSIQ and each time you get a refill. There may be new information. This information does not take the place of talking to your healthcare provider about your medical condition or your treatment. Step 3: Remove the larger bore Do not share your syringes or needles with anyone else. You may give an infection needle (e.g., 25 G) from the to them or get an infection from them. package. Pick up the syringe and place the needle on the Supplies needed to give your STRENSIQ injection (See Figure A): tip of the syringe. Push down • 1 or 2 STRENSIQ vial(s). and twist the needle onto • 1 or 2 sterile disposable 1 mL syringes for injection with 25 to 29 gauge (G), the syringe until it is tight. ½ inch needles. Step 4: Hold the syringe with the o The use of two different gauge needles is recommended, a larger needle pointing up and pull bore needle (e.g. 25 gauge) for withdrawal of the medication, and back the plunger until the a smaller bore needle (e.g. 29 gauge) for the injection. top of the plunger reaches o Always use a new syringe and needle for each injection.
    [Show full text]
  • Development of a Wood Plastic Composite Extruder
    l o rna f Wa ou s J te l a R n e Akinfiresoye et al., Int J Waste Resour 2017, 7:3 o s i o t u International Journal a r n c r DOI: 10.4172/2252-5211.1000295 e e t s n I ISSN: 2252-5211 of Waste Resources ResearchResearch Article Article Open Access Development of a Wood Plastic Composite Extruder WA Akinfiresoye*, OJ Olukunle and AA Akintade Department of Agricultural and Bio-Environmental Engineering Technology, Rufus Giwa Polytechnic, Owo, Ondo State, Nigeria Abstract Wood plastic composites (WPC) is the recycling of wood flour and plastic into new products like particle boards, floor tiles and other structural building applications. An extruding machine is developed at the workshop of Agricultural and Environmental Engineering Department of The Federal University of Technology, Akure, Ondo State to handle the production of these products. The major components of the machine include the melting/mixing chamber, the extruding chamber, the frame and the discharging chamber. The working principle of the machine is by allowing the recycled shredded plastic to melt at 200°C before adding the wood flour and mixed thoroughly. This is now fed into the extruding chamber at same temperature which further kneads the mixture into slurry before discharging it into a mould of dimension 150 mm × 80 mm × 70 mm. The machine is powered by 10 Hp three phase electric motor. Specimen produced is now hot-pressed at 120°C to a thickness of 13mm and allowed to cool before removal. The machine had a throughput of 0.78 kg/hr and functional efficiency of 86%.
    [Show full text]
  • Care and Use Guide Vacuum Insulated Stainless Steel Food Jar with Containers
    CARE AND USE GUIDE VACUUM INSULATED STAINLESS STEEL FOOD JAR WITH CONTAINERS GENERAL CARE · Before first use, and as soon as possible after each use, wash all parts with warm, soapy water. Rinse all parts thoroughly and allow time to dry. · Contents should not be left in the container for longer than 24 hours. As soon as possible after each and every use, wash all parts with warm, soapy water. Rinse all parts thoroughly with clean water. Allow all parts to dry completely prior to next use or storage. · DO NOT use abrasive cleaners or scrubbers since they may dull the finish. · DO NOT use bleach or cleaners containing chlorine on any parts of the product. · All components of this product are top rack dishwasher safe; however, hand washing is recommended as the dishwasher uses harsher detergents and hot water that may affect the appearance of your product. · Residual liquids, foods, or other contents may become trapped between product components, such as lid parts, container parts, gaskets (flexible band around lid and/or stopper), or straws (if present in the product). Hand washing is recommended to ensure that all parts of the product are thoroughly cleaned. · For maximum insulation efficiency (for stainless steel compartment only), preheat or pre-chill the compartment just prior to use. Fill with hot/cold tap water, insert stopper and attach lid, let stand 5 to 10 minutes, and empty water. After filling compartment with contents, or with the containers, re-cover product with stopper and lid to increase thermal efficiency. Never use microwave, conventional oven, or other heat source for this purpose.
    [Show full text]
  • Stopper 'Pop-Up' and the Effects on Container Closure Integrity Of
    APPLICATION NOTE Stopper ‘Pop-Up’ and the Effects on Container Closure Integrity of Freeze Dried Vials• AN107 V1.0 INTRODUCTION Container closure integrity (CCI) plays an important role in maintaining the stability and sterility of lyophilized products. Lyophilization is a complex process that presents many manufacturing challenges one of which is maintaining and monitoring container closure integrity. At the end of the lyophilization process, prior to sealing finished vials at the end of secondary drying, a lyophilization chamber is typically backfilled to a nitrogen gas pressure that is specified for the vial headspace. The specified headspace pressure varies from product to product. Typically, freeze dried products are stoppered at partial vacuum (0.5 to 0.9 atm of nitrogen pressure) – some products can be sealed under full vacuum (0 atm absolute pressure). The vacuum level serves the practical purpose of helping to seat the stopper and to facilitate reconstitution. Once equilibrium is achieved, the gas pressure in the vial headspace matches the chamber pressure and the shelves are lowered to seat the stoppers into the vial. At this point the vial closure integrity is established but not considered complete until the aluminum seal is applied. Once the shelves are raised, the seal integrity must be maintained for a period of time ranging from minutes to hours to possibly days before unloading and capping occur. It is possible during this time for stoppers to “pop-up” allowing gas ingress into the vial headspace. Stoppers can pop up due to a number of reasons including improper seating during shelf lowering, out of specification stopper and/or vial flange dimensions, and stopper coatings.
    [Show full text]