Adaptive Optical Microscopy for Neurobiology
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Two-Photon Excitation, Fluorescence Microscopy, and Quantitative Measurement of Two-Photon Absorption Cross Sections
Portland State University PDXScholar Dissertations and Theses Dissertations and Theses Fall 12-1-2017 Two-Photon Excitation, Fluorescence Microscopy, and Quantitative Measurement of Two-Photon Absorption Cross Sections Fredrick Michael DeArmond Portland State University Let us know how access to this document benefits ouy . Follow this and additional works at: https://pdxscholar.library.pdx.edu/open_access_etds Part of the Physics Commons Recommended Citation DeArmond, Fredrick Michael, "Two-Photon Excitation, Fluorescence Microscopy, and Quantitative Measurement of Two-Photon Absorption Cross Sections" (2017). Dissertations and Theses. Paper 4036. 10.15760/etd.5920 This Dissertation is brought to you for free and open access. It has been accepted for inclusion in Dissertations and Theses by an authorized administrator of PDXScholar. For more information, please contact [email protected]. Two-Photon Excitation, Fluorescence Microscopy, and Quantitative Measurement of Two-Photon Absorption Cross Sections by Fredrick Michael DeArmond A dissertation submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy in Applied Physics Dissertation Committee: Erik J. Sánchez, Chair Erik Bodegom Ralf Widenhorn Robert Strongin Portland State University 2017 ABSTRACT As optical microscopy techniques continue to improve, most notably the development of super-resolution optical microscopy which garnered the Nobel Prize in Chemistry in 2014, renewed emphasis has been placed on the development and use of fluorescence microscopy techniques. Of particular note is a renewed interest in multiphoton excitation due to a number of inherent properties of the technique including simplified optical filtering, increased sample penetration, and inherently confocal operation. With this renewed interest in multiphoton fluorescence microscopy, comes increased interest in and demand for robust non-linear fluorescent markers, and characterization of the associated tool set. -
Wavefront Decomposition and Propagation Through Complex Models with Analytical Ray Theory and Signal Processing Paul Cristini, Eric De Bazelaire
Wavefront decomposition and propagation through complex models with analytical ray theory and signal processing Paul Cristini, Eric de Bazelaire To cite this version: Paul Cristini, Eric de Bazelaire. Wavefront decomposition and propagation through complex models with analytical ray theory and signal processing. 2006. hal-00110279 HAL Id: hal-00110279 https://hal.archives-ouvertes.fr/hal-00110279 Preprint submitted on 27 Oct 2006 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. March 31, 2006 14:7 WSPC/130-JCA jca_sbrt Journal of Computational Acoustics c IMACS Wavefront decomposition and propagation through complex models with analytical ray theory and signal processing P. CRISTINI CNRS-UMR5212 Laboratoire de Mod´elisation et d'Imagerie en G´eosciences de Pau Universit´e de Pau et des Pays de l'Adour BP 1155, 64013 Pau Cedex, France [email protected] E. De BAZELAIRE 11, Route du bourg 64230 Beyrie-en-B´earn, France [email protected] Received (Day Month Year) Revised (Day Month Year) We present a novel method which can perform the fast computation of the times of arrival of seismic waves which propagate between a source and an array of receivers in a stratified medium. -
Replace This with the Actual Title Using All Caps
THREE-PHOTON MICROSCOPY AT 1700 NM FOR IN VIVO IMAGING A Dissertation Presented to the Faculty of the Graduate School of Cornell University In Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy by Nicholas Geoffrey Horton May 2015 © 2015 Nicholas Geoffrey Horton THREE-PHOTON MICROSCOPY AT 1,700 NM FOR IN VIVO IMAGING Nicholas Geoffrey Horton, Ph. D. Cornell University 2015 Multiphoton fluorescence microscopy (MPM) allows scientists to noninvasively observe structures deep within tissue. Two-photon microscopy (2PM) in the 750-1000 nm excitation region has been the standard MPM technique since its first demonstration in 1990. However, the maximum imaging depth for 2PM is limited by the signal-to-background ratio (SBR). In this dissertation, three-photon imaging at 1700 nm excitation wavelength (1700 nm 3PM) is presented. The combination of the long excitation wavelength and the higher order nonlinear excitation overcomes the SBR limitations of 2PM, enabling biological investigations to take place at greater depth within tissue. In chapter 1, tissue imaging is discussed, paying special attention to the development of laser scanning fluorescence microscopy. In chapter 2, non-invasive, high resolution, in vivo imaging of subcortical structures within an intact mouse brain using 1700 nm 3PM is presented. Vascular structures as well as red fluorescent protein (RFP)-labeled neurons within the mouse hippocampus are imaged. In chapter 3, dispersion compensation of 1700 nm 3PM is discussed. Signal generation in 3PM is proportional to the inverse-squared of the pulse width. We show that the high normal dispersion of a silicon wafer can be conveniently used to compensate the anomalous dispersion of a 1,700 nm excitation three-photon microscope. -
Model-Based Wavefront Reconstruction Approaches For
Submitted by Dipl.-Ing. Victoria Hutterer, BSc. Submitted at Industrial Mathematics Institute Supervisor and First Examiner Univ.-Prof. Dr. Model-based wavefront Ronny Ramlau reconstruction approaches Second Examiner Eric Todd Quinto, Ph.D., Robinson Profes- for pyramid wavefront sensors sor of Mathematics in Adaptive Optics October 2018 Doctoral Thesis to obtain the academic degree of Doktorin der Technischen Wissenschaften in the Doctoral Program Technische Wissenschaften JOHANNES KEPLER UNIVERSITY LINZ Altenbergerstraße 69 4040 Linz, Osterreich¨ www.jku.at DVR 0093696 Abstract Atmospheric turbulence and diffraction of light result in the blurring of images of celestial objects when they are observed by ground based telescopes. To correct for the distortions caused by wind flow or small varying temperature regions in the at- mosphere, the new generation of Extremely Large Telescopes (ELTs) uses Adaptive Optics (AO) techniques. An AO system consists of wavefront sensors, control algo- rithms and deformable mirrors. A wavefront sensor measures incoming distorted wave- fronts, the control algorithm links the wavefront sensor measurements to the mirror actuator commands, and deformable mirrors mechanically correct for the atmospheric aberrations in real-time. Reconstruction of the unknown wavefront from given sensor measurements is an Inverse Problem. Many instruments currently under development for ELT-sized telescopes have pyramid wavefront sensors included as the primary option. For this sensor type, the relation between the intensity of the incoming light and sensor data is non-linear. The high number of correcting elements to be controlled in real-time or the segmented primary mirrors of the ELTs lead to unprecedented challenges when designing the control al- gorithms. -
Megakernels Considered Harmful: Wavefront Path Tracing on Gpus
Megakernels Considered Harmful: Wavefront Path Tracing on GPUs Samuli Laine Tero Karras Timo Aila NVIDIA∗ Abstract order to handle irregular control flow, some threads are masked out when executing a branch they should not participate in. This in- When programming for GPUs, simply porting a large CPU program curs a performance loss, as masked-out threads are not performing into an equally large GPU kernel is generally not a good approach. useful work. Due to SIMT execution model on GPUs, divergence in control flow carries substantial performance penalties, as does high register us- The second factor is the high-bandwidth, high-latency memory sys- age that lessens the latency-hiding capability that is essential for the tem. The impressive memory bandwidth in modern GPUs comes at high-latency, high-bandwidth memory system of a GPU. In this pa- the expense of a relatively long delay between making a memory per, we implement a path tracer on a GPU using a wavefront formu- request and getting the result. To hide this latency, GPUs are de- lation, avoiding these pitfalls that can be especially prominent when signed to accommodate many more threads than can be executed in using materials that are expensive to evaluate. We compare our per- any given clock cycle, so that whenever a group of threads is wait- formance against the traditional megakernel approach, and demon- ing for a memory request to be served, other threads may be exe- strate that the wavefront formulation is much better suited for real- cuted. The effectiveness of this mechanism, i.e., the latency-hiding world use cases where multiple complex materials are present in capability, is determined by the threads’ resource usage, the most the scene. -
Wide. Fast. Deep. Recent Advances in Multi-Photon Microscopy of in Vivo Neuronal Activity
TechSights Wide. Fast. Deep. Recent Advances in Multi- Photon Microscopy of in vivo Neuronal Activity https://doi.org/10.1523/JNEUROSCI.1527-18.2019 Cite as: J. Neurosci 2019; 10.1523/JNEUROSCI.1527-18.2019 Received: 2 March 2019 Revised: 27 September 2019 Accepted: 27 September 2019 This Early Release article has been peer-reviewed and accepted, but has not been through the composition and copyediting processes. The final version may differ slightly in style or formatting and will contain links to any extended data. Alerts: Sign up at www.jneurosci.org/alerts to receive customized email alerts when the fully formatted version of this article is published. Copyright © 2019 the authors 1 Wide. Fast. Deep. Recent Advances in Multi-Photon Microscopy of in vivo Neuronal Activity. 2 Abbreviated title: Recent Advances of in vivo Multi-Photon Microscopy 3 Jérôme Lecoq1, Natalia Orlova1, Benjamin F. Grewe2,3,4 4 1 Allen Institute for Brain Science, Seattle, USA 5 2 Institute of Neuroinformatics, UZH and ETH Zurich, Switzerland 6 3 Dept. of Electrical Engineering and Information Technology, ETH Zurich, Switzerland 7 4 Faculty of Sciences, University of Zurich, Switzerland 8 9 Corresponding author: Jérôme Lecoq, [email protected] 10 Number of pages: 24 11 Number of figures: 6 12 Number of tables: 1 13 Number of words for: 14 ● abstract: 196 15 ● introduction: 474 16 ● main text: 5066 17 Conflict of interest statement: The authors declare no competing financial interests. 18 Acknowledgments: We thank Kevin Takasaki and Peter Saggau (Allen Institute for Brain Science) for providing helpful 19 comments on the manuscript; we thank Bénédicte Rossi for providing scientific illustrations. -
Wavefront Coding Fluorescence Microscopy Using High Aperture Lenses
Wavefront Coding Fluorescence Microscopy Using High Aperture Lenses Matthew R. Arnison*, Carol J. Cogswelly, Colin J. R. Sheppard*, Peter Törökz * University of Sydney, Australia University of Colorado, U. S. A. y Imperial College, U. K. z 1 Extended Depth of Field Microscopy In recent years live cell fluorescence microscopy has become increasingly important in biological and medical studies. This is largely due to new genetic engineering techniques which allow cell features to grow their own fluorescent markers. A pop- ular example is green fluorescent protein. This avoids the need to stain, and thereby kill, a cell specimen before taking fluorescence images, and thus provides a major new method for observing live cell dynamics. With this new opportunity come new challenges. Because in earlier days the process of staining killed the cells, microscopists could do little additional harm by squashing the preparation to make it flat, thereby making it easier to image with a high resolution, shallow depth of field lens. In modern live cell fluorescence imag- ing, the specimen may be quite thick (in optical terms). Yet a single 2D image per time–step may still be sufficient for many studies, as long as there is a large depth of field as well as high resolution. Light is a scarce resource for live cell fluorescence microscopy. To image rapidly changing specimens the microscopist needs to capture images quickly. One of the chief constraints on imaging speed is the light intensity. Increasing the illumination will result in faster acquisition, but can affect specimen behaviour through heating, or reduce fluorescent intensity through photobleaching. -
Topic 3: Operation of Simple Lens
V N I E R U S E I T H Y Modern Optics T O H F G E R D I N B U Topic 3: Operation of Simple Lens Aim: Covers imaging of simple lens using Fresnel Diffraction, resolu- tion limits and basics of aberrations theory. Contents: 1. Phase and Pupil Functions of a lens 2. Image of Axial Point 3. Example of Round Lens 4. Diffraction limit of lens 5. Defocus 6. The Strehl Limit 7. Other Aberrations PTIC D O S G IE R L O P U P P A D E S C P I A S Properties of a Lens -1- Autumn Term R Y TM H ENT of P V N I E R U S E I T H Y Modern Optics T O H F G E R D I N B U Ray Model Simple Ray Optics gives f Image Object u v Imaging properties of 1 1 1 + = u v f The focal length is given by 1 1 1 = (n − 1) + f R1 R2 For Infinite object Phase Shift Ray Optics gives Delta Fn f Lens introduces a path length difference, or PHASE SHIFT. PTIC D O S G IE R L O P U P P A D E S C P I A S Properties of a Lens -2- Autumn Term R Y TM H ENT of P V N I E R U S E I T H Y Modern Optics T O H F G E R D I N B U Phase Function of a Lens δ1 δ2 h R2 R1 n P0 P ∆ 1 With NO lens, Phase Shift between , P0 ! P1 is 2p F = kD where k = l with lens in place, at distance h from optical, F = k0d1 + d2 +n(D − d1 − d2)1 Air Glass @ A which can be arranged to|giv{ze } | {z } F = knD − k(n − 1)(d1 + d2) where d1 and d2 depend on h, the ray height. -
Adaptive Optics: an Introduction Claire E
1 Adaptive Optics: An Introduction Claire E. Max I. BRIEF OVERVIEW OF ADAPTIVE OPTICS Adaptive optics is a technology that removes aberrations from optical systems, through use of one or more deformable mirrors which change their shape to compensate for the aberrations. In the case of adaptive optics (hereafter AO) for ground-based telescopes, the main application is to remove image blurring due to turbulence in the Earth's atmosphere, so that telescopes on the ground can "see" as clearly as if they were in space. Of course space telescopes have the great advantage that they can obtain images and spectra at wavelengths that are not transmitted by the atmosphere. This has been exploited to great effect in ultra-violet bands, at near-infrared wavelengths that are not in the atmospheric "windows" at J, H, and K bands, and for the mid- and far-infrared. However since it is much more difficult and expensive to launch the largest telescopes into space instead of building them on the ground, a very fruitful synergy has emerged in which images and low-resolution spectra obtained with space telescopes such as HST are followed up by adaptive- optics-equipped ground-based telescopes with larger collecting area. Astronomy is by no means the only application for adaptive optics. Beginning in the late 1990's, AO has been applied with great success to imaging the living human retina (Porter 2006). Many of the most powerful lasers are using AO to correct for thermal distortions in their optics. Recently AO has been applied to biological microscopy and deep-tissue imaging (Kubby 2012). -
Huygens Principle; Young Interferometer; Fresnel Diffraction
Today • Interference – inadequacy of a single intensity measurement to determine the optical field – Michelson interferometer • measuring – distance – index of refraction – Mach-Zehnder interferometer • measuring – wavefront MIT 2.71/2.710 03/30/09 wk8-a- 1 A reminder: phase delay in wave propagation z t t z = 2.875λ phasor due In general, to propagation (path delay) real representation phasor representation MIT 2.71/2.710 03/30/09 wk8-a- 2 Phase delay from a plane wave propagating at angle θ towards a vertical screen path delay increases linearly with x x λ vertical screen (plane of observation) θ z z=fixed (not to scale) Phasor representation: may also be written as: MIT 2.71/2.710 03/30/09 wk8-a- 3 Phase delay from a spherical wave propagating from distance z0 towards a vertical screen x z=z0 path delay increases quadratically with x λ vertical screen (plane of observation) z z=fixed (not to scale) Phasor representation: may also be written as: MIT 2.71/2.710 03/30/09 wk8-a- 4 The significance of phase delays • The intensity of plane and spherical waves, observed on a screen, is very similar so they cannot be reliably discriminated – note that the 1/(x2+y2+z2) intensity variation in the case of the spherical wave is too weak in the paraxial case z>>|x|, |y| so in practice it cannot be measured reliably • In many other cases, the phase of the field carries important information, for example – the “history” of where the field has been through • distance traveled • materials in the path • generally, the “optical path length” is inscribed -
Shack–Hartmann Wavefront Sensor with Array of Phase Coded Masks
Shack–Hartmann wavefront sensor with array of phase coded masks NITIN DUBEY,* RAVI KUMAR, JOSEPH ROSEN School of Electrical and Computer Engineering, Ben-Gurion University of the Negev, P.O. Box 653, Beer-Sheva 8410501, Israel *Corresponding author: [email protected] Shack-Hartmann wavefront sensors (SHWS) are generally used to measure the wavefront curvature of light beams. Measurement accuracy and the sensitivity of these sensors are important factors for better wavefront sensing. In this study, we demonstrate a new type of SHWS with better measurement accuracy than the regular SHWS. The lenslet array in the regular SHWS is replaced with an array of coded phase masks and the principle of coded aperture correlation holography (COACH) is used for wavefront reconstruction. Sharper correlation peaks achieved by COACH improve the accuracy of the estimated local slopes of the measured wavefront and consequently improve the reconstruction accuracy of the overall wavefront. Experimental results confirm that the proposed method provides a lower mean square wavefront error by one order of magnitude in comparison to the regular SHWS. Shack-Hartmann wavefront sensor (SHWS) was developed for pattern created by illuminating a single CPM with a plane wave. The optical metrology purposes [1] and later has been used in various intensity response in each cell of the array is shifted according to the other fields, such as adaptive optics [2], microscopy [3], retinal average slope of the wavefront in each corresponding cell. Composing imaging [4], and high-power laser systems [5]. Usually, in SHWS a the entire slopes yields a three-dimensional curvature used as an microlens array is used to measure the wavefront local gradients. -
From Scattering to Wavefronts: What’S in Between? Michael Mrochen, Phd
From Scattering to Wavefronts: What’s in between? Michael Mrochen, PhD Swiss Federal Institute of Technology Institute of Biomedical Engineering IROC Institute for Refractive and Oculoplastic Surgery Zürich Switzerland Foreword • This is a report on a work in progress ! • Geometric-optical methods are used to develop an analytical theory for surface scattering on rough surface sturctures (irregular structures). • Parts of this work are published in: – SPIE Proceedings Ophthalmic Technologies (1998,1999) – Laser Physics 12: 1239-1256 (2002) – Laser Physics 12: 1333-1348 (2002) Clinical observation: Hartmann -Shack and Tscherning wavefront measurements demonstrate an increased background noise when the tearfilm breaks up. Clinical observation: Hartmann -Shack and Tscherning wavefront measurements demonstrate an increased background noise before and after LASIK After LASIK Before LASIK Clinical observation: Some eyes have irregular surface structures that are not reasonably described in terms of modes (Zernike, Taylor, ...) Striae Cornea after complicated LASIK BSCVA: 20/50 decentered measurement Centered measurement Problem ! Clinical observations indicate that there are other sources of optical errors that are not detected or described or measured by the currently used wavefront sensors. -> Visual symptoms do not correlate well with wavefront data in such complicated cases Question ?! What are the optical effects of such irregular structures ? Irregular structures = surface roughness Optical effects of that might detoriate the image quality