QUICK SETUP GUIDE RF-HTS3117, 12-Outlet Surge Protector
Total Page:16
File Type:pdf, Size:1020Kb
QUICK SETUP GUIDE RF-HTS3117, 12-outlet Surge Protector PACKAGE CONTENTS Protected LED indicator USING YOUR SURGE PROTECTOR • 12-outlet surge protector Main power 1 Plug the surge protector’s power cord into a standard 120V AC outlet. If the LEDs do not light up, press the main power switch/circuit breaker on the front of • Quick Setup Guide Grounded LED indicator switch the unit. 2 Plug the power cords from up to twelve devices into the AC outlets on the surge protector. 3 Plug your USB devices into the USB ports to power or charge them. FEATURES AC adapter spaced outlets 4 Plug in Ethernet or telephone cables to the data line surge protection ports. Be sure to follow the correct direction for INPUT (what is coming out of the wall • Protects equipment from damaging power surges and spikes. or from the modem) and OUTPUT (what is going to a cable box or Blu‐ray player). An additional Ethernet or telephone cable is required (not included). • Firestop design advanced MOVs with built-in fuses minimize fire hazards 5 Plug in a coax cable from cable TV, satellite TV, or for your cable Internet connection. Two sets are provided. Either one can be used if only one device is being from major power surges. connected. Be sure to follow the correct direction for INPUT (what is coming from the wall) and OUTPUT (what is going to a cable box or TV). An additional coax cable is required (not included). • Incorporates noise filtering to reduce EMI/RFI interference and provide AC outlets “clean” power that will maximize the performance of your equipment. USB ports • Twelve AC outlets provide continuous AC power. SPECIFICATIONS • Six AC adapter spaced outlets accommodate bulky AC adapter plugs. AC adapter spaced outlets • Main power switch/circuit breaker controls power to all AC outlets on the Coaxial cable Dimensions (L×W×H) (not including plug) 12.2" × 4.88" × 1.34" (310 × 124 × 34 mm) surge protection Data line surge protector, and allows the unit to be reset after a circuit overload has resolved. surge protection ELECTRICAL SPECIFICATIONS: • Two USB charging or power ports, 2.1A total charge current, for fast charging of Load rating 15 amps smartphones, tablets, or other devices. Line voltage 125V AC @ 60 Hz • Protected LED indicator lights when the surge protection feature is working properly. Note: If this LED does not light or goes out, the surge protection feature has reached full capacity and can no longer absorb additional surges and spikes. The surge protector Surge protection 3 lines (L-N / L-G / N-G) should be replaced if this light goes out. Maximum surge current 135,000 amps • Grounded LED indicator lights when a properly grounded AC outlet is detected. Note: If this LED does not light, we recommend that you contact a certified, licensed electrician to inspect your wiring. Maximum energy dissipation 4,680 joules • 6 ft (1.8 m) Soft-Flex™ power cord with right-angle/off-set plug enables placement of the surge protector in the desired location. The right-angle plug Clamping voltage L-N / L-G / N-G = 500 volts allows you to place furniture as close as possible to the wall and not block the second AC outlet. EMI/RFI noise filtering Up to 47 dB • Data line surge protection protects your incoming RJ11 (phone) or RJ45 (Ethernet) line from surges and spikes. Compatible with Gigabit Ethernet Surge protector certification UL-1449 certified • Coaxial cable surge protection protects two sets of your incoming coaxial cable lines from surges and spikes. USB output 2.1 amps total OTHER SPECIFICATIONS: Connected equipment limited warranty $350,000 max Before using your new product, please read these instructions to prevent any damage. SAFETY PRECAUTIONS ONE-YEAR LIMITED PRODUCT WARRANTY • RISK OF ELECTRIC SHOCK - Use only in dry locations and only indoors. See included warranty sheet, visit www.rocketfishproducts.com, or call 800-620-2790 for additional connected equipment and product warranty • DO NOT plug into another extension cord or power strip. information or for customer service. • DO NOT plug surge protectors into other surge protectors. • DO NOT use with any aquarium equipment. CONTACT ROCKETFISH: • DO NOT use if correctly grounded outlets are not available. For customer service, call 1-800-620-2790 • DO NOT install this device if there is not at least 30 feet (10 meters) or more of wire between the electrical outlet and the electrical service panel. www.rocketfishproducts.com • This device features internal protection that will disconnect the surge protective component at the end of its useful life, but will maintain power to the load – WHICH WILL BE UNPROTECTED. If you don’t want your equipment at risk, follow the manufacturer’s instructions for replacing the device. ROCKETFISH is a trademark of Best Buy and its affiliated companies. LEGAL NOTICES Distributed by Best Buy Purchasing, LLC 7601 Penn Ave South, Richfield, MN 55423 U.S.A. FCC STATEMENT ©2016 Best Buy. All rights reserved. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, Made in China and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. V1 ENGLISH 16-0506.