High Efficiency Inverter Range

Air Cooled Split Ducted & Rooftop Packaged Units

> Highly efficient and reliable brushless DC inverter scroll for variable capacity control

> Wide model range with nominal capacities from 20kW to 180kW

> BMS compatible with BACnet as standard

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Why Choose Inverter?

Disadvantages of Fixed Speed Compressors

A fixed speed cannot modulate its capacity. Instead it can only switch on or off so that the remains within allowable upper and lower limits. The result is: Upper Hysteresis • Fluctuations in room temperature. Limit of 25°C Setpoint • Suboptimal energy efficiency. of 24°C Lower Hysteresis • Increased compressor wear due to constant Limit of 23°C starting and stopping. Compressor Compressor Compressor Compressor Room Temperature Room • Spikes in current draw during compressor On Off On Off start-up. Time • Fatigue of pipework in the absence of compressor soft-starting. Fixed capacity temperature control in cooling mode.

Digital Scroll Compressors - Only a Partial Solution

A digital uses a digitally controlled mechanical unloader to engage and disengage the scrolls while the motor runs continuously at a fixed speed and thus avoids the on / off cycles of the fixed speed compressor. This fully engaged or non-engaged capacity cycle delivers temperature control without the disadvantages of starting and stopping a fixed speed compressor.

However, efficiency is low as there is still substantial power consumed during the disengaged intervals, and it falls with refrigeration load reduction. As air conditioners typically spend most of their life operating under design capacity, the digital scroll compressor will therefore consume more energy than other available options.

Full Compression 50% Load Full Load COP Zero Compression

Digital Scroll 10 seconds 10 seconds

20 seconds Capacity

A typical 50% capacity loading sequence Indicative COP vs. capacity profile of a of a digital scroll compressor. digital scroll compressor.

2 Serving the HVAC industry since 1961

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Why Choose Inverter?

Advantages of Inverter Compressors

BLDC inverter compressors have a high efficiency permanent magnet motor that can be electronically speed controlled to modulate the mass flow rate through the refrigeration circuit. The benefits are: Temp. • Greater temperature control precision with capacity turn-down ratios of typically 5:1.

• Significantly improved COP during capacity turn-down because of the reduced condensing to evaporating pressure differential. This results in large overall energy Setpoint savings as air conditioners typically spend minimal time of 24°C at design capacity.

• Reduced compressor wear due to the largely diminished

need for compressor on/off cycling. Temperature Room

• Reduced stress on refrigeration pipework due to Time compressor soft-starting. Inverter temperature • No spikes in current draw during compressor start-up due control in cooling mode. to soft-starting.

• Reduced compressor noise during capacity turn-down.

• The ability to be used in (VAV) installations.

• The ability to operate at higher ambient temperatures with greater control over condensing pressure.

50% Load Full Load Inverter Condensing Pressure

Evaporating Pressure

Pressure COP

Reduced Differential Digital Scroll

Enthalpy Capacity

The reduced evaporating to condensing Indicative COP vs. capacity profile of an pressure differential during capacity inverter compressor. turn-down of inverter compressors greatly improves efficiency.

Serving the HVAC industry since 1961 3

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Dunnair Inverter Range Features

Refrigeration Dunnair Inverter units use BLDC inverter compressors and electronic expansion valves to achieve a wide range of capacity control (turn-down to approx. 20% capacity per compressor) and optimal energy efficiency.

Fans Dunnair Inverter units use high efficiency EC fans for supply air. These can be balanced for (CAV) applications, or alternatively speed can be modulated for Variable Air Volume (VAV) applications. EC axial fans are used for the condenser air and their speed is modulated by the integrated head pressure control to ensure stability of the DX system.

Control Dunnair Inverter units come standard with LLI and BACnet HLI for unit operation and monitoring. Touchscreen displays are also available as an option for convenient standalone operation. The inverter compressors are safeguarded by thorough protection logic integrated into the onboard control system.

Economy Cycle Dunnair Inverter units are available with economy cycle dampers as an option. When conditions are suitable, these allow for free-cooling which saves significant amounts of energy.

4 Serving the HVAC industry since 1961

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Dunnair Inverter Range Features

BLDC Inverter Compressors EC Supply Air & Condenser Air Fans

HLI and Touchscreen Display Economy Cycle (option)

Serving the HVAC industry since 1961 5

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Specifications

Packaged Inverter Range

Model Cooling Capacity Heating Capacity Nominal Supply Refrigerant Compressor Input Power Full Load Amps Range (kW)* Range (kW) Airflow (l/s) Type (V/Ph/Hz) (A) PH 20-I 5.6 - 20 7.3 - 26 1100 R410A BLDC Inverter 415 / 3 / 50 24 PH 30-I 8.3 - 30 10.8 - 39 1800 R410A BLDC Inverter 415 / 3 / 50 38 PH 40-I 5.6 - 40 7.3 - 52 2200 R410A BLDC Inverter 415 / 3 / 50 44 PH 50-I 8.3 - 50 10.8 - 65 2800 R410A BLDC Inverter 415 / 3 / 50 68 PH 80-I 6.1 - 80 7.9 - 104 4300 R410A BLDC Inverter 415 / 3 / 50 87 PH 90-I 9.8 - 90 12.7 - 117 4800 R410A BLDC Inverter 415 / 3 / 50 95 PH 120-I 12.2 - 120 15.9 - 156 6500 R410A BLDC Inverter 415 / 3 / 50 168 PH 140-I 12.2 - 140 15.9 - 182 7500 R410A BLDC Inverter 415 / 3 / 50 168 PH 160-I 12.2 - 160 15.9 - 208 8500 R410A BLDC Inverter 415 / 3 / 50 168 PH 180-I 19.6 - 180 25.5 - 234 9500 R410A BLDC Inverter 415 / 3 / 50 180 >PH 180-I Custom Design

*Cooling capacities are based on 35°C air-on outdoor coil and 27°C air-on indoor coil.

- Configuration A

Spigots can be relocated to the top, side, or bottom of the unit

- Duct Configuration B (mirrored)

Spigots can be relocated to the top, side, or bottom of the unit

6 Serving the HVAC industry since 1961

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Specifications

Min Front Clearance: Min Side Clearance: 1000mm 1000mm Unit Width

Unit Length

Min Side Clearance: 1000mm PLAN VIEW Unit Height SA Spigot Height RA Spigot Height

Compressor & SA Spigot RA Spigot Electrical Access Condenser Coil Fan Access Width Width

FRONT VIEW SIDE VIEW BACK VIEW

Packaged Unit Dimensions* Model Unit Length Unit Width Unit Height RA Spigot RA Spigot SA Spigot SA Spigot Weight (kg) (mm) (mm) (mm) Width (mm) Height (mm) Width (mm) Height (mm) PH 20-I 2095 1740 1065 350 450 350 450 400 PH 30-I 2475 1800 1090 350 550 350 550 550 PH 40-I 2740 1800 1305 350 900 350 900 680 PH 50-I 3395 1800 1450 350 1050 350 1050 860 PH 80-I 3540 2070 1980 350 1550 350 1550 1160 PH 90-I 3530 2070 2080 350 1550 350 1550 1250 PH 120-I 4330 1940 2000 500 1600 500 1600 2050 PH 140-I 4490 2070 2350 500 1950 500 1950 2540 PH 160-I 4490 2070 2350 500 1950 500 1950 2540 PH 180-I 4690 2070 2665 500 1950 500 1950 3080 >PH 180-I Custom Design *Dimensions and weight are indicative only, contact your Dunnair representative for detailed unit drawings.

Serving the HVAC industry since 1961 7

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Specifications

Split Ducted Inverter Range

Model Cooling Capacity Heating Capacity Nominal Supply Refrigerant Compressor Input Power Full Load Amps Range (kW) Range (kW) Airflow (l/s) Type (V/Ph/Hz) (A) SH 20-I 5.6 - 20 7.3 - 26 1100 R410A BLDC Inverter 415 / 3 / 50 30 SH 30-I 8.3 - 30 10.8 - 39 1800 R410A BLDC Inverter 415 / 3 / 50 50 SH 40-I 5.6 - 40 7.3 - 52 2200 R410A BLDC Inverter 415 / 3 / 50 44 SH 50-I 8.3 - 50 10.8 - 65 2800 R410A BLDC Inverter 415 / 3 / 50 68 SH 80-I 6.1 - 80 7.9 - 104 4300 R410A BLDC Inverter 415 / 3 / 50 88 SH 90-I 9.8 - 90 12.7 - 117 4800 R410A BLDC Inverter 415 / 3 / 50 96 SH 120-I 12.2 - 120 15.9 - 156 6500 R410A BLDC Inverter 415 / 3 / 50 160 SH 140-I 12.2 - 140 15.9 - 182 7500 R410A BLDC Inverter 415 / 3 / 50 165 SH 160-I 12.2 - 160 15.9 - 208 8500 R410A BLDC Inverter 415 / 3 / 50 165 SH 180-I 19.6 - 180 25.5 - 234 9500 R410A BLDC Inverter 415 / 3 / 50 180 >SH 180-I Custom Design

*Cooling capacities are based on 35°C air-on outdoor coil and 27°C air-on indoor coil. Pipework Connections Unit Width

Min Side Clearance: 1000mm Unit Length

PLAN VIEW SA Spigot Width RA Spigot Width Height Height SA Spigot RA Spigot Unit Height

FRONT VIEW SIDE VIEW BACK VIEW Indoor Unit Dimensions Model Unit Length Unit Width Unit Height RA Spigot RA Spigot SA Spigot SA Spigot Weight (kg) (mm) (mm) (mm) Width (mm) Height (mm) Width (mm) Height (mm) SH 20-I 590 1556 385 1455 310 990 225 61 SH 30-I 720 1900 485 1700 385 882 262 132 SH 40-I 1200 1300 990 1040 777 507 507 220 SH 50-I 1200 1600 990 1320 777 507 507 290 SH 80-I 1250 2200 1040 1960 884 569 569 485 SH 90-I 1350 2430 1190 2000 984 638 638 516 SH 120-I 1550 2300 1550 2150 1300 715 715 660 SH 140-I 1600 2650 1550 2500 1300 715 715 660 SH 160-I 1800 2850 1550 2700 1300 801 801 760 SH 180-I 1850 3050 1650 2900 1400 801 801 820 >SH 180-I Custom Design *Dimensions and weight are indicative only, contact your Dunnair representative for detailed unit drawings.

8 Serving the HVAC industry since 1961

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Specifications

Split Ducted Inverter Range

Min Back Clearance: 500mm Min Front Clearance: 500mm Unit Width

Unit Length Min Side Clearance: 1000mm PLAN VIEW

Compressor & Pipework Electrical Access Connections Unit Height

Condenser Coil Condenser Coil FRONT VIEW SIDE VIEW BACK VIEW

Outdoor Unit Dimensions* Model Unit Length Unit Width Unit Height Weight (kg) (mm) (mm) (mm) SH 20-I 400 940 1245 120 SH 30-I 950 1300 1140 276 SH 40-I 1550 1200 1215 220 SH 50-I 1800 1755 1120 530 SH 80-I 1800 1800 1225 615 SH 90-I 1800 2080 1415 700 SH 120-I 2050 2050 1560 1100 SH 140-I 2050 2050 2065 1180 SH 160-I 2050 2050 2065 1250 SH 180-I 2150 2150 2665 1340 >SH 180-I Custom Design *Dimensions and weight are indicative only, contact your Dunnair representative for detailed unit drawings.

Serving the HVAC industry since 1961 9

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Dunnair Inverter Expertise

Broughton Anglican College -Air cooled inverter packaged unit

Dunnair supplied a 140kW air cooled inverter packaged unit to condition a school assembly hall. Economy cycle dampers were included which allow for energy saving free-cooling when conditions are suitable, and modulate

to deliver outside air as CO2 levels rise. A touchscreen controller was also supplied for convenient unit operation.

Royal Military College Duntroon -Air cooled inverter split ducted units

Dunnair supplied two air cooled inverter split ducted units for Australia’s army officer training academy. Each unit had a nominal capacity of 100kW and the split DX configuration allowed for easy installation into the existing facility.

10 Serving the HVAC industry since 1961

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz Dunnair Inverter Expertise

Westlawn Commercial Building -Vertical water cooled inverter units used in a VAV system

Dunnair supplied ten water cooled inverter units as replacements for old units with staged compressors and direct drive fans. With long term government tenants occupying the building, the client opted for a high efficiency HVAC solution by upgrading to units with inverter compressors and EC plug fans. The factory control systems were expanded to manage supply air discharge pressure and suit the Variable Air Volume (VAV) installation.

Refer to the Dunnair water cooled Inverter brochure for more information on this range.

DELWP Offices Melbourne -Vertical water cooled inverter units used in a VAV system

Dunnair supplied nine water cooled inverter units for use in a Variable Air Volume (VAV) system. The smooth capacity modulation of the inverter compressors made these units the ideal solution as they allow the BMS to maintain a constant supply air temperature while the supply air volume is varied in order to match cooling demands. The VAV design approach allowed for multiple-zone (achieved with VAV terminal units) and lower overall fan noise.

Refer to the Dunnair water cooled Inverter brochure for more information on this range.

Serving the HVAC industry since 1961 11

Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz DUNNAC Pty Ltd Head Office: Ashford Avenue, Milperra NSW 2214 p 02 8774 1400 e [email protected] w www.dunnair.com.au Dunnair Victoria: p 03 9482 1010 e [email protected] Dunnair Queensland: p 07 3891 1974 e [email protected]