Symbol of Switches, Push-Buttons, Circuit Switches

Total Page:16

File Type:pdf, Size:1020Kb

Symbol of Switches, Push-Buttons, Circuit Switches Electrical & Electronic Symbols www.electrical-symbols.com Symbol of Switches, Push-buttons, Circuit Switches ... [ Go to Website ] 1/10 Open switch Switch with delayed Switch with delayed Closed switch Generic symbol opening opening and closing Double Switch Switch with delayed Switch delay when Double switch bipolar opening opening and closing bipolar One closes before the other Double limit switch Limit switch When one closes Float switch Thermal switch another opens Level switch fluid Time switch Open thermal switch Closed termal switch Differential switch Timer Thermal magnetic Switch with neon lamp Limiter Electronic limiter switch incorporated DIP DIP Mercury switch (Dual In-line Package) encapsulated switches Inclination or motion Starter Encapsulated switches e.g. 3 switches detector All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Symbol of Switches, Push-buttons, Circuit Switches ... [ Go to Website ] 2/10 Contact driven Selector Foot operated switch Time switch by a pulse counter All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Circuit Switch Symbols [ Go to Website ] 3/10 Switch, SDPT Switch, SDPT Double Switch, DPDT (A pole double throw) Slide switch, SDPT (A pole double throw) (Double pole double Generic symbol throw) Double Switch, DPDT (Double pole double Multi-switch Multi-switch Multi-switch throw) Rotary switch Rotating multi-switch Multi-switch Multi-switch Rotating multi-switch All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Push-buttons / Push Switch Symbols [ Go to Website ] 4/10 Open Push-button Closed push-button Open Pushbutton Closed pushbutton Pushbutton Pushbutton Double limit switch Pushbutton limit pushbutton Telegraph key Joystick switch One closes and another opens Double pushbutton Pushbutton circuit One closes and another switch opens All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Symbols of Switches of Two and Three Positions [ Go to Website ] 5/10 switch switch Opening or resting Inverter switch before Closing or work contact Closing or work contact contact closing Generic symbol Inverter switch with Inverter switch before Inverter switch before intermediate cutting Double closing contact opening opening position Circuit switch Double opening contact Cutting contact before making contact All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Disconnectors / Unipolar Switch Symbols [ Go to Website ] 6/10 Disconnectors Contact Disconnectors Open rotating contact open pushbutton close pushbutton manual contact Without automatic With automatic return With automatic return Generic symbol return after closure after closure after opening Pushbutton with Contact Contact Close rotating contact mushroom head Squeegee switch Open pushbutton Without automatic With positive operation With automatic locking Positive contact return after opening of opening contact and and return operation fixed position All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Symbols of Position Switches [ Go to Website ] 7/10 Dual position switch position switch with Position contact Position contact mechanically operated positive opening Closing contact Opening contact in both directions operation of NC contact All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Symbols of Contacts with Automatic Return and Position Maintained [ Go to Website ] 8/10 Inverter Switch with intermediate position Shutdown switch with Opening switch with Closing switches with with automatic return automatic return automatic return maintained position in position and without automatic return in the opposite All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Symbols of Operation Switches with Advanced or Delayed [ Go to Website ] 9/10 Delayed closing switch Early opening switch Early shutdown switch Delayed opening switch All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07 Electrical & Electronic Symbols www.electrical-symbols.com Symbols of Switches of Step in Two-Position [ Go to Website ] 10/10 Step switch with Step switch with Step switch with momentary closing momentary closing momentary closing when its control device when its control device when its control device is activated is disabled is toggle on or off All Electrical & Electronic Symbols in https://www.electrical-symbols.com © AMG - Some rights reserved - This file is licensed under the Creative Commons (CC BY-NC 4.0) license - https://creativecommons.org/licenses/by-nc/4.0/deed.en - Rev.07.
Recommended publications
  • Guide for Identifying Mercury Switches/Thermostats in Common Appliances
    Guide for Identifying Mercury Switches/Thermostats in Common Appliances Prepared by: Jim Giordani, Burlington Board of Health, Revised 12/27/00 Contact Todd Dresser for Further information at (781) 270-1956 - 1 - Guide for Identifying Mercury Switches/Thermostats In Common Appliances This reference contains guidance for responding to a mercury spill, and how to recycle mercury bearing products. This document also contains specific recommendations for the following types of products: batteries, fluorescent lights, high intensity discharge lamps (HID) lamps, ballasts, thermostats, switches, float switches, sump pumps, silent light switches, washing machines, tilt switches, freezers, flow meters, manometers, barometers, vacuum gauges, flame sensors on gas appliances, rubber flooring containing mercury, and mercury accumulation in sanitary drains. This reference also contains a general checklist of products found to routinely contain mercury. Mercury is a dangerous element in the environment today. It can cause serious health problems such as neurological and kidney damage. Mercury is found in many products that end up in landfills and incinerators allowing the mercury to re-enter the environment and pollute drinking water and contaminate the food chain. The following information is a helpful guide to identify products that contain mercury switches and thermostats. This guide describes where mercury switches and thermostats are located and how to remove and dispose of these properly. Mercury bearing articles should not be thrown in the trash, and serious care should be taken when dealing with this element. Safe Disposal · Store mercury thermostats and switches in a suitable sturdy, sealed container. A five gallon plastic bucket with a lid may work. · Each container must be labeled "Mercury Thermostats or Switches/Universal Waste." · Be careful to keep the devices from breaking and releasing mercury into the environment.
    [Show full text]
  • Mercury Switch-To-Microswitch Retrofit Kit KA349WE Instructions
    Reclosers COOPER POWER Effective October 2015 MN280022EN Supersedes S280-40-10 April 2014 SERIES Mercury switch to microswitch retrofit kit KA349WE installation instructions DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation’s (“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use
    [Show full text]
  • Household Appliance Mercury Switch Removal Manual
    HOUSEHOLD APPLIANCE MERCURY SWITCH REMOVAL MANUAL Chest Freezers Sump and Bilge Pump Float Switches Gas Ranges Washing Machines October 2004 Parts of the following document were reproduced from: VERMONT’S HOUSEHOLD APPLIANCE MERCURY SWITCH REMOVAL MANUAL SPRING 2002 Special thanks to the following people and organizations for help in the development of that manual: Gary Winnie of the Chittenden Solid Waste District (CSWD), Gary Hobbs of the Addison County Solid Waste District (ACSWD), The Northeast Kingdom Waste Management District (NEKWMD), The Association of Home Appliance Manufactures (AHAM), Purdue University, and the Vermont Recycling & Hazardous Waste Coordinators Networks. Any questions, comments, corrections or requests for additional copies should be directed to the: Maine Department of Environmental Protection 17 State House Station Augusta, Maine 04333-0017 Attention: Mercury Products Program Division of Solid Waste Management Telephone: (207) 287-2651 This document is available on the Internet at: www.maine.gov/dep/mercury TABLE OF CONTENTS 1.0 INTRODUCTION 1 2.0 HOUSEHOLD APPLIANCE MERCURY REMOVAL 4 2.1 Chest Freezer 4 2.2 Washing Machines 6 2.3 Gas Ranges 8 2.4 Gas Hot-water Heaters 12 2.5 Sump and Bilge Pumps 13 3.0 MERCURY HANDLING, STORAGE AND DISPOSAL 14 3.1 Handling 14 3.2 Storage 14 3.3 Transportation Requirements 17 3.4 Training Requirements 17 3.5 Disposal 17 3.6 Closure 18 4.0 MERCURY SPILL CLEAN-UP 18 REFERENCES APPENDICES APPENDIX A Regulatory Forms and Instructions APPENDIX B Mercury Spill Clean-up Plan and Spill Kit List APPENDIX C Mercury Switch Transporters & Recyclers for Maine 1.0 INTRODUCTION What is mercury? Mercury is a naturally occurring metal.
    [Show full text]
  • Preface About Sunfounder Sunfounder Is a Technology Company Focused on Raspberry Pi and Arduino Open Source Community Development
    Preface About SunFounder SunFounder is a technology company focused on Raspberry Pi and Arduino open source community development. Committed to the promotion of open source culture, we strive to bring the fun of electronics making to people all around the world and enable everyone to be a maker. Our products include learning kits, development boards, robots, sensor modules and development tools. In addition to high quality products, SunFounder also offers video tutorials to help you build your own project. If you have interest in open source or making something cool, welcome to join us! Visit www.sunfounder.com for more! About Sensor Kit V1.0 This kit is suitable for SunFounder Uno, SunFounder Mega 2560, SunFounder Duemilanove and SunFounder Nano. All the code in this user manual is compatible with these boards. Our SunFounder board is fully compatible with Arduino board. You can go to our official website www.sunfounder.com to download related code by clicking LEARN -> Get Tutorials. If you have any questions, please send an email to [email protected]. Also welcome to leave a message and share your projects on our FORUM. Note: This kit is different from other kits. All the components in this kit are provided in the form of modules which integrate some necessary components, such as comparator, resistor, and capacitor and so on. Therefore it is convenient for circuit connection. SunFounder Reprint 2.0 Contents Components List .................................................................................................................................
    [Show full text]
  • Five Signs That It Is Time to Replace the Mercury Based Relays and Switches in Your Industrial Application
    • white paper • white paper • white paper • white paper • industry: industrial process heating author: brian bettini Five Signs That it is Time to Replace the Mercury Based Relays and Switches in Your Industrial Application And What to Look for in a Suitable Replacement Summary: Mercury relays have been used in industrial applications for decades, most commonly for power switching. For example, in applications that use process heating, mercury relays are traditionally used to power on and off of electric heaters efficiently. But these kinds of relays are being replaced for several reasons. The latest generation of mercury relay/mercury switch alternatives is safer and more accurate and just as durable. • white paper • white paper • The background: mercury in industry U.S. patents for a mercury-based relay can be found as far back as 1937, and they have been used in industry for decades.1 They were first developed for applications where contact erosion could present a challenge for more conventional relay contacts, or where constant cycling was needed (such as heating operations). Mercury relays have been known to overheat, however, and there have been known cases of relays exploding and sending vaporized mercury into the workspace. This can potentially create a serious environmental and safety issue, not to mention the need for costly clean-up. But even with that risk, and with the EPA and the European Union placing bans on the use of mercury, some manufacturers are still using mercury relays or similar outdated switching devices. Why? Some industrial engineers claim to prefer mercury relays because they believe them to be durable and capable of handling difficult and dirty environments.
    [Show full text]
  • In-Service Mercury Switch Review July 11, 2003
    In-Service Mercury Switch Review July 11, 2003 Conducted by the: Michigan Department of Environmental Quality Environmental Science and Services Division Pollution Prevention and Compliance Assistance Section 7/21/2003 1 of 32 Michigan In-Service Review v3.4.doc In-Service Mercury Switch Review Outline I. Executive Summary II. Introduction and Review Purpose (Why In-Service?) III. Existing Programs (Literature Review and Interviews) A. New York B. Oregon IV. Switch Removal Process/Disposal A. Switch Removal Procedures B. Switch Removal/Replacement Times C. Vehicle Marking D. Potential Locations (sites) for Removal/Replacement E. Potential Stakeholders for In-Service Program F. Issues for Consideration i. Incentives ii. Consumer Factors iii. Regulatory Considerations iv. Spills v. Complexity of Procedure(s) V. Conclusions and Observations VI. Citations VII. Appendices A. Members of the In-Service Review Group B. Schram Auto Parts E-mail C. MDEQ Survey on Switch Replacement Process D. Reynolds and Reynolds Citation, Shaheen Chevrolet E. New York Green Dot Marking Procedure F. Oregon Program NATA Survey G. Oregon Program E-mail to Ecology Center Inquiry H. Oregon Program Overview; NATA I. Label Construction J. Comments 7/21/2003 2 of 32 Michigan In-Service Review v3.4.doc I. Executive Summary A legislative requirement in the Michigan Department of Environmental Quality’s (MDEQ’s) fiscal year (FY) 2003 budget appropriation directed the MDEQ to perform a review of in-service automotive mercury switch removal. To address this mandate, the MDEQ conducted a review of existing in-service removal programs, collected available information from automotive maintenance technical manuals, and interviewed government, interest groups and industry representatives.
    [Show full text]
  • Picosecond Pulse Generators Using Microminiature Mercury Switches
    NBSIR 74-377 PICOSECOND PULSE GENERATORS USING MICROMINIATURE MERCURY SWITCHES James R. Andrews Electromagnetics Division Institute for Basic Standards National Bureau of Standards Boulder, Colorado 80302 March 1974 Final Report Prepared for Department of Defense Calibration Coordination Group 72-66 NBSIR 74-377 PICOSECOND PULSE GENERATORS USING MICROMINIATURE MERCURY SWITCHES James R. Andrews Electromagnetics Division Institute for Basic Standards National Bureau of Standards Boulder, Colorado 80302 March 1974 Final Report Prepared for Department of Defense Calibration Coordination Group 72-66 U.S. DEPARTMENT OF COMMERCE, Frederick B. Dent, Secretary NATIONAL BUREAU OF STANDARDS Richard W Roberts Director TABLE OF CONTENTS Page I. INTRODUCTION 1 II. FLAT PULSE GENERATOR CONCEPT 5 III. PRELIMINARY WORK 6 IV. ALTERNATE SWITCH CONFIGURATIONS STUDIED 7 V. COMMERCIAL STRIPLINE SWITCH EVALUATION 8 VI. NBS STRIPLINE SWITCH 13 VII. CLASSICAL MERCURY SWITCH PULSE GENERATOR 16 VIII. CONCLUSIONS 17 REFERENCES 18 LIST OF FIGURES Figure Page 2-1 Diode switch flat pulse generator 21 2- 2 Mercury switch flat pulse generator 21 3- 1 Basic SPDT microminiature mercury wetted switch 22 3-2 DIP IC mercury switch pulse generator 23 3-3 Transition time measurement set-up 24 3-4 Transient step response of measurement set-up. Hori- zontal scale is 100 ps/div. 24 3- 5 Pulse output from DIP IC mercury switch pulse generator. Horizontal scale is 200 ps/div. 25 4- 1 Microminiature mercury switched mounted in a 14 mm insertion unit 26 4- 2 Pulse output of a microminiature switch mounted in a 14 mm insertion unit. Horizontal scale is 100 ps/div.- 26 5- 1 Microminiature mercury switch in commercial strip line package 27 5-2 TDR characteristics of commercial stripline micro- miniature mercury switch, (a) Port 2 to Port 1.
    [Show full text]
  • Basic Electricity
    BASIC ELECTRICITY STUDY COURSE for Home Appliances HOW TO READ: • WIRING DIAGRAM SYMBOLS • TERMINAL CODES • WIRING DIAGRAMS CABINET GROUND BK W STARTER BALLAST S 1 FLUORESCENT LAMP Module 2 LIT 787740 Rev. C For More Appliance Troubleshooting, Repair Help, & DIY Videos Visit ApplianceAssistant.com Note: This Page was not included by Whirlpool Corporation ApplianceAssistant.com is not affiliated Whirlpool Corporation Whirlpool Corporation in no way endorses ApplianceAssistant.com WHIRLPOOL CORPORATION does not assume any responsibility or any liability in connection with the use of this manual. © 1989, 1993, 2000 WHIRLPOOL CORPORATION All rights reserved. No portion of this book may be reproduced in any form without written permission from WHIRLPOOL CORPORATION. ® The trademarks WHIRLPOOL , , , and FSP are registered trademarks of Whirlpool Corporation. INTRODUCTION The material presented in this module is intended to provide you with an understanding of the fundamentals of electricity as applied to major appliances. Major appliances have become more sophisticated, taking them out of the screwdriver and pliers category. Their electrical circuits include several different types of automatic controls, switches, heaters, valves, etc.. Semiconductors, solid-state controls, and other components usually associated with radio and television electronic circuits, are being engineered into automatic washers, dryers, dishwashers, and refrigerators. The appliance technician is emerging into a professional status of his own. He must prepare himself now to be able to perform his duties today as well as to retain his professionalism in the future. No longer is on-the-job training sufficient to prepare technicians for the complicated procedures required for todays sophisticated appliances. This training can best be obtained through organized classroom study and application.
    [Show full text]
  • Removal of Vehicle Mercury Switch Assemblies
    Fact Sheet: Removal of Vehicle Mercury Switch Assemblies Hazardous Waste and Toxics Reduction Program Remove all mercury switch assemblies from vehicles as soon as possible after they enter the facility. Removal of mercury switches is quick and easy. Auto recyclers throughout Washington state report it takes approximately 30–60 seconds to remove the entire mercury light switch assembly. ABS G-Force Sensors take 5–7 minutes. Tools found most useful in doing the job include wire cutters, screwdriver, ratchet, wrench, pry bar, and pliers. Mercury Convenience Light Switches Any vehicle equipped with a convenience light in the hood and/or trunk is likely to have mercury switches if it’s a 2002 or older Ford or GM, or a 1998 or older Chrysler. Removing mercury hood and trunk convenience lights 1. Lift the hood or trunk and locate the small mercury lighting switch assembly. Refer to the Auto Mercury Switch Removal poster1 that lists the make/model, year, and location of switch, (e.g., hood or trunk). 2. Disconnect the battery. 3. Find the small light fixture on the underside of the hood or trunk. 4. Cut the wires leading to the device. 5. Remove the light assembly from vehicle. Unscrew, unbolt, or pry the light fixture from the hood/trunk. 6. Place light assembly in labeled container. You may remove as much of the device as possible to make more room in the container. Figure 1. Removal of hood and trunk convenience light switches Please note: In some instances (such as many GM vehicles), leaving the assembly intact and removing the pellet may be easier than removing the entire assembly.
    [Show full text]
  • Picosecond Pulse Generators Using Microminiature Mercury Switches
    NBSIR 74-377 PICOSECOND PULSE GENERATORS USING MICROMINIATURE MERCURY SWITCHES James R. Andrews Electromagnetics Division Institute for Basic Standards National Bureau of Standards Boulder, Colorado 80302 March 1974 Final Report Prepared for Department of Defense Calibration Coordination Group 72-66 NBSIR 74-377 PICOSECOND PULSE GENERATORS USING MICROMINIATURE MERCURY SWITCHES James R. Andrews Electromagnetics Division Institute for Basic Standards National Bureau of Standards Boulder, Colorado 80302 March 1974 Final Report Prepared for Department of Defense Calibration Coordination Group 72-66 U.S. DEPARTMENT OF COMMERCE, Frederick B. Dent, Secretary NATIONAL BUREAU OF STANDARDS Richard W Roberts Director TABLE OF CONTENTS Page I. INTRODUCTION 1 II. FLAT PULSE GENERATOR CONCEPT 5 III. PRELIMINARY WORK 6 IV. ALTERNATE SWITCH CONFIGURATIONS STUDIED 7 V. COMMERCIAL STRIPLINE SWITCH EVALUATION 8 VI. NBS STRIPLINE SWITCH 13 VII. CLASSICAL MERCURY SWITCH PULSE GENERATOR 16 VIII. CONCLUSIONS 17 REFERENCES 18 LIST OF FIGURES Figure Page 2-1 Diode switch flat pulse generator 21 2- 2 Mercury switch flat pulse generator 21 3- 1 Basic SPDT microminiature mercury wetted switch 22 3-2 DIP IC mercury switch pulse generator 23 3-3 Transition time measurement set-up 24 3-4 Transient step response of measurement set-up. Hori- zontal scale is 100 ps/div. 24 3- 5 Pulse output from DIP IC mercury switch pulse generator. Horizontal scale is 200 ps/div. 25 4- 1 Microminiature mercury switched mounted in a 14 mm insertion unit 26 4- 2 Pulse output of a microminiature switch mounted in a 14 mm insertion unit. Horizontal scale is 100 ps/div.- 26 5- 1 Microminiature mercury switch in commercial strip line package 27 5-2 TDR characteristics of commercial stripline micro- miniature mercury switch, (a) Port 2 to Port 1.
    [Show full text]
  • Owner's Manual
    Owner’s Manual Pediatric Mid-Wheel Drive Wheelchair Supplier: This manual must be given to the user of this wheelchair. User: Before using this wheelchair read this entire manual and save for future reference. I. INTRODUCTION SUNRISE LISTENS USER WARNING Thank you for choosing a Quickie wheelchair. We want WARNING to hear your questions or comments about this manual, Attention wheelchair users, do not operate this wheelchair the safety and reliability of your chair, and the service you without first reading the owner’s manual. If you do not receive from your Sunrise supplier. Please feel free to write understand the instructions and warnings of this owner’s or call us at the address and telephone number below: manual please contact your dealer or qualified technician before operating this Quickie wheelchair. Failure to do so may result in damage and/or injury. Sunrise Medical Customer Service Department DEALER/TECHNICIAN WARNING 237 Romina Drive, Unit 3 WARNING Concord, Ontario, Canada Attention dealers and qualified technicians, do not operate L4K 4V3 or service this wheelchair without first reading this owner’s 1-800-263-3390 manual. If you do not understand the instructions and warnings of this owner’s manual please contact the Quickie Technical Service Department before operating and/or FOR ANSWERS TO YOUR QUESTIONS servicing this Quickie wheelchair. Failure to do so may Your authorized supplier knows your wheelchair best, and result in damage and/or injury. can answer most of your questions about chair safety, use and maintenance. For future reference, fill in the following: WARNING Supplier: In addition, power wheelchairs may contain printed circuit ______________________________________________ boards.
    [Show full text]
  • An Access-Dictionary of Internationalist High Tech Latinate English
    An Access-Dictionary of Internationalist High Tech Latinate English Excerpted from Word Power, Public Speaking Confidence, and Dictionary-Based Learning, Copyright © 2007 by Robert Oliphant, columnist, Education News Author of The Latin-Old English Glossary in British Museum MS 3376 (Mouton, 1966) and A Piano for Mrs. Cimino (Prentice Hall, 1980) INTRODUCTION Strictly speaking, this is simply a list of technical terms: 30,680 of them presented in an alphabetical sequence of 52 professional subject fields ranging from Aeronautics to Zoology. Practically considered, though, every item on the list can be quickly accessed in the Random House Webster’s Unabridged Dictionary (RHU), updated second edition of 2007, or in its CD – ROM WordGenius® version. So what’s here is actually an in-depth learning tool for mastering the basic vocabularies of what today can fairly be called American-Pronunciation Internationalist High Tech Latinate English. Dictionary authority. This list, by virtue of its dictionary link, has far more authority than a conventional professional-subject glossary, even the one offered online by the University of Maryland Medical Center. American dictionaries, after all, have always assigned their technical terms to professional experts in specific fields, identified those experts in print, and in effect held them responsible for the accuracy and comprehensiveness of each entry. Even more important, the entries themselves offer learners a complete sketch of each target word (headword). Memorization. For professionals, memorization is a basic career requirement. Any physician will tell you how much of it is called for in medical school and how hard it is, thanks to thousands of strange, exotic shapes like <myocardium> that have to be taken apart in the mind and reassembled like pieces of an unpronounceable jigsaw puzzle.