Determination of Suiphite, Sulphur Dioxide, Thiosulphate and Thiocyanate, with Notes on the Determination of Total Sulphur and Other Sulphur Compounds 1985

Total Page:16

File Type:pdf, Size:1020Kb

Determination of Suiphite, Sulphur Dioxide, Thiosulphate and Thiocyanate, with Notes on the Determination of Total Sulphur and Other Sulphur Compounds 1985 Determination of Suiphite, Sulphur Dioxide, Thiosulphate and Thiocyanate, with Notes on the Determination of Total Sulphur and Other Sulphur Compounds 1985 Methods for the Examination of Waters and Associated Materials HMSO This document contains L 6 ci pages Determination of Suiphite, Sulphur Dioxide, Thiosulphate and Thiocyanate, with Notes on the Determination of Total Sulphur and Other Sulphur Compounds 1985 Methods for the Examination of Waters and Associated Materials London Her Majesty's Stationery Office This booklet supplements the booklets in this series on the determination of sulphates and sulphides. It contains much general information of use in the analysis of samples containing other forms of sulphur. Five specificmethods for Sulphite and Sulphur Dioxide, Thiosulphate and Thiocyanate are given. This is followed by a section on ways of determining the total sulphur content of a variety of samples followed by a review type discussion of ways of proceeding should a significantamount of the sulphur presentbe in other forms than those mentioned and there be a need to know either what forms are present,or whether the sample contains certain specific sulphur compounds. The layout is as follows: Introduction, including (i) suitability of the methods given, (ii) a list of forms in which sulphur has been foundto occur in water, sludge and sediment samples, and (iii) a note on ultra-precise titration. A. A spectrophotometric method for Suiphite and Sulphur Dioxide using pararosaniline B. A titrimetric method for Sulphite and Sulphur Dioxide by iodometry C. A titrimetric method for Thiosulphate in simple solutions by iodometry D. Manual colorimetric and volumetric methods for thiocyanate using ferric ions E. An automatedcolorimetric method for Thiocyanate using ferric ions F. Methodsfor the determination of Total Sulphur G. Notes on other methods for analysing complex mixtures of sulphur compounds H. Notes on Analytical Quality Control References Although many of the methods in this booklet are well known and widely used, due to a scarcity of test data all must be regardedas tentative. I,' Contents About this series i Warning to users 2 Introduction 3 Suitability of methods given in this booklet 3 Sulphur compounds which may be present in samples 6 Note on accurate measurement using burettes and pipettes 9 Figuresl&2 11 A Determination of Suiphite and Sulphur Dioxide by Pararosaniline Spectrophotometricmethod 12 Al Performance characteristics 12 A2 Principle 12 A3 Interference 13 A4 Hazards 13 AS Reagents 13 A6 Apparatus 15 A7 Sampling and sample preservation 15 A8 Analytical procedure 16 A9 Sources of error 17 AlO Checking the accuracy of analytical results 18 B Determination of Suiphite and Sulphur Dioxide by lodometry 19 Bi Performance characteristics 19 B2 Principle 19 B3 Interferences 20 B4 Reagents 21 B5 Apparatus 21 B6 Sampling and sample preparation 22 B7 Analytical procedure 22 B8 Calculation 22 B9 Sources of error 23 BlO Checking the accuracy of analytical results 23 Bil Preparation of Oxygen Free Nitrogen 23 C Determination of Thiosuiphate by lodometry 25 Cl Performance characteristics 25 C2 Principle 26 C3 Interferences 26 C4 Reagents 26 CS Apparatus 27 C6 Sampling and sample preparation 28 C7 Analytical procedure 28 C8 Calculation 29 C9 Changes of range 30 ClO Sources of error 30 Cli Checking the accuracy of analytical results 31 D Determination of Thiocyanate, Manual Colorimetric and Volumetric Methods 32 Dl Performance characteristics 32 D2 Principle 33 D3 Interferences 34 D4 Hazards 35 D5 Reagents 35 D6 Apparatus 36 D7 Sample storage and preservation 36 D8 Volumetric analytical procedure 36 D9 Manual colorimetric analytical procedure 37 DiO Sulphide removal procedure 38 Dli Analytical quality control 38 D12 Silver, Mercury and Cadmium recovery 38 E Determination of Thiocyanate. Automated Colorimetric Method 39 El Performance characteristics 39 E2 Principle 40 E3 Interferences 40 E4 Hazards 42 E5 Reagents 42 E6 Apparatus 43 E7 Analytical procedure 43 E8 Extending the range of the method upwards 45 E9 Removal of interferences 45 ElO A dialysis procedure for Coke Oven Effluents high in Thiocyanate 46 Ell Checking the accuracy of analytical results 47 F Determination of the Total Sulphur Content 49 Sulphur recoveries for these methods 49 Fl Objective 50 F2 Principle 50 F3 Preliminary discussion 50 F4 Aqueous Alkaline Bromine Oxidation 51 F41 Hazards F4.2 Reagents F4.3 Apparatus F4.4 Procedure F5 Hydrogen Peroxide Oxidation 52 F5.1 Hazard F5.2 Reagent F5.3 Apparatus F5.4 Procedure F6 Peroxide Fusion method 53 F6.1 Reagent F6.2 Apparatus F6.3 Procedure F7 Oxygen Flask method 54 F8 Other combustion methods 55 F9 Spectrophotometric direct methods 55 F9.1 X-ray fluorescence F9.2 Ultra-violet emission spectrophotometry F9.3 Inductively Coupled Plasma Emission Spectrophotometry F9.4 Flame Photometry FlO Sources of error 56 G Other Techniques which have been used for analysingcomplex mixtures of Sulphur Compounds 57 Gi Methylene Blue Colorimetric 57 G2 Reaction with Cyanide 57 03 Ion Chromatography and HPLC 57 G4 Potentiometry 57 05 Polarography 58 06 Electrophoresis 58 G7 Packed column and thin layer chromotography. and gas chromotography 58 G8 Direct Spectrophotometry 58 G9 Determination of Dithiocarbamates 58 H Analytical Quality Control 59 References 60 Address for Correspondence 61 Membership responsible for this method 62 London 11cr Majesty's Stationery Office About this series This booklet is part of a series intended to provide both of Analysts (to review Standard Methods for Quality recommended methods for the determination of water Control of the Water Cycle). The Standing Committee quality, and in addition, short reviews of the more of Analysts is a committee of the Department of the important analytical techniques of interest to the water Environment set up in 1972. Currently it has 7 Working and sewage industries. Groups, each responsible for one section or aspect of water cycle quality analysis. They are as follows: In the past, the Departmentof the Environment and its predecessors, in collaboration with various learned 1.0 General principles of sampling and accuracy of societies, have issued volumes of methods for the results analysis of water and sewage culminating in Analysis 3.0 Empirical and physical methods of Raw, Potable and Waste Waters'. These volumes 4.0 Metals and metalloids inevitably took some years to prepare, so that they 5.0 General nonmetallic substances were often partially out of date before they appeared in 6.0 Organic impurities print. The present series will be published as a series of 7.0 Biological methods booklets on single or related topics; thus allowing for 9.0 Radiochemical methods the replacement or addition of methods as quickly as possible without need of waiting for the next edition. The actual methods and reviews are produced by The rate of publication will also be related to the smaller panels of expertsin the appropriate field, under urgency of requirement for that particular method, the overall supervision of the appropriate working tentative methods and notes being issued when group and the main committee. necessary. The names of those associated with this method are The aim is to provide as complete and up to date a listed inside the back cover. Publication of new or collection of methods and reviews as is practicable, revised methods will be notified to the technical press, which will, as far as possible, take into account the whilst a list of Methods in Print is given in the current analytical facilities available in different parts of the HMSO Sectional Publication List No 5. Kingdom, and the quality criteria of interest to those responsible for the various aspects of the water cycle. Whilst an effort is made to prevent errors from occur- Because both needs and equipment vary widely, where ring in the published text, a few errors have been found necessary, a selection of methods may be recom- in booklets in this series. Correction notes and minor mended for a single determinand. It will be the additions to published booklets not warranting a new responsibility of the users — the senior technical staff to booklet in this series will be issued periodically as the decide which of these methods to use for the deter- need arises. Should an error be found affecting the mination in hand. Whilst the attention of the user is operation of a method, the true sense not being drawn to any special known hazards which may occur obvious, or an error in the printed text be discovered with the use of any particular method, responsibilityfor prior to sale, a separate correction note will he issued proper supervision and the provision of safe working for inclusion in that booklet. conditions must remain with the user. L R Pittwell The preparation of this series and its continuous Secretary revision is the responsibility of the Standing Committee 1 July 1986 1 Warning to users The analytical procedures given in this booklet should and wastes, containment in the event of breakage, only be carriedout by competent trainedpersons. with access to taps, escape routes, and the accessibility of adequate supervision when necessary. the correct and properlymaintained first-aid, fire-fight- ing, and rescue equipment. Hazardous reagents and Local Safety Regulations must be observed. solutions should always be stored in plain sight and below face level. Attention should also be given to Laboratory procedures should be carried out only in potential vapour and fire risks. If in doubt, it is
Recommended publications
  • Semester –I Chapter 4: Redox Titrations
    Semester –I Chapter 4: Redox Titrations SHREE H. N. SHUKLA INSTITUTE OF PHARMACEUTICAL EDUCATION AND RESEARCH B.PHRAM (SEMESTER –I) SUBJECT NAME: PHARMACEUTICAL ANALYSIS -I SUBJECT CODE: BP102TP CHAPTER 4: REDOX TITRATIONS H.N. Shukla Institute of Pharmaceutical Education and Research Page 1 Semester –I Chapter 4: Redox Titrations Content Redox titrations: (a) Concepts of oxidation and reduction (b) Types of redox titrations (Principles and applications) Cerimetry, Iodimetry, Iodometry, Bromatometry, Dichrometry, Titration with potassium iodate INTRODUCTION Concept of oxidation and reduction As discussed before, in titrimetric analysis we can find out the quantity of pure component based on measurement of volume of standard solution that reacts completely with the analyte. This measurement of standard solution can be possible in different reactions, and if the reaction involved in this measurement is oxidation-reduction reaction, that method is called ns "oxidation reduction titration" or "Redox titration. In Redox titration oxidation & Reduction reaction occurs simultaneously. Oxidation Combination of the substance with oxygen is termed as oxidation. C (s) + O2 (g) CO2 (g) Removal of Hydrogen H2S + O S + H2O Loss of electron(s) is known as oxidation. By loosing electron positive valency of element increases and negative valency of element decreases. Fe2+ Fe3+ + e- Increase in oxidation number Reduction Removal of Oxygen from substance CuO + 2H Cu + H2O Additon of Hydrogen C2H2 + 2H C2H4 Gain of electron, by taking on electron positive valency is decreased and negative valency is increased. Fe3+ + e- Fe2+ Decrease in Oxidation number. H.N. Shukla Institute of Pharmaceutical Education and Research Page 2 Semester –I Chapter 4: Redox Titrations Oxidation-Reduction Reaction Oxidation-reduction reactions are the chemical processes in which a change in the valency of reacting elements or ions takes place.
    [Show full text]
  • A Rapid, High-Throughput Iodometric Titration Method for The
    ntimicrob A ia f l o A l g a e n n r t u s o Mangum et al., J Antimicrob Agents 2017, 3:4 J Journal of Antimicrobial Agents DOI: 10.4172/2472-1212.1000152 ISSN: 2472-1212 Research Article Open Access A Rapid, High-Throughput Iodometric Titration Method for the Determination of Active Chlorine Content of Topical Antiseptic Solutions Mangum LC1*, Garcia GR1, Niece KL2, Wenke JC1 and Akers KS1,3 1Extremity Trauma and Regenerative Medicine, US Army Institute of Surgical Research, JBSA Fort Sam Houston, Texas, USA 2Axon Dx, LLC, Earlysville, Virginia, USA 3Brooke Army Medical Center, JBSA Fort Sam Houston, Texas, USA *Corresponding author: Lee C. Mangum, PhD, Extremity Trauma and Regenerative Medicine, US Army Institute of Surgical Research, 3698 Chambers Pass, Bldg 3611, Ft. Sam Houston, Texas, USA 78234 Tel: +210-539-9701; E-mail: [email protected] Received date: October 8, 2017; Accepted date: October 23, 2017; Published date: October 24, 2017 Copyright: © 2017 Mangum LC, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Abstract Objective: A considerable number of commercially available topical antiseptic solutions rely on free available chlorine as an active ingredient due to its broad-spectrum antimicrobial activity, but limited empirical knowledge exists of the degradation kinetics of chlorine-based solutions in contact with host tissue. To better inform clinical practice, we developed and qualified a rapid and sensitive semi-automated microtiter plate-based iodometric titration assay suitable for the rapid determination of free available chlorine in small samples of dilute antiseptic solutions following contact with biological materials.
    [Show full text]
  • 2019 Xylem Analytics Wastewater and Drinking Water Catalog
    Wastewater and Drinking Water XYLEM SOLUTIONS CATALOG 2019-2020 Innovative Solutions for Challenging Problems Xylem, is committed to providing our customers with solutions to their most challenging problems through the use of our expertise and innovative technology. As part of that commitment, Xylem continues to develop and launch new innovative product lines, building upon our proven sensor and analytics technology. We take pride in improving and setting new standards in the markets that we serve. Content Company Introduction ����������������������� 3 Category ���������������������������� 4 - 5 Featured Products ������������������������ 6 - 7 Dissolved Oxygen ���������������������� 8 - 9 Biochemical Oxygen Demand ���������������� 10 - 11 pH / ORP / Ion Concentration ���������������� 12 - 15 Multi-Parameter and Conductivity �������������� 16 - 17 Turbidity / Color / Suspended Solid �������������� 18 - 19 Chemical Oxygen Demand ����������������� 20 - 21 Photometry ������������������������� 22 - 23 Piston Burette . Titration ������������������� 24 - 29 Online Controllers & Sensors �����������������30 - 43 Flow, Level & Samplers ������������������� 44 - 47 Total Organic Carbon �������������������� 48 - 49 Xylem Brands ������������������������� 50 - 51 2 Welcome to Xylem Inc. Company Overview Xylem Analytics is a leading manufacturer of field, portable, online and laboratory analytical instrumentation. Xylem’s analytical involvement spans right across the laboratory platform, from potable water analysis, through food, beverage, chemical, petrochemical,
    [Show full text]
  • REDOX TITRATIONS with IODINE Introduction
    REDOX TITRATIONS WITH IODINE Introduction The shelf life of pharmaceutical products must always be tested. Hydrogen peroxide used in disinfectants is slowly reduced to water; it also photodegrades. Vitamin C in vitamin tablets is inherently unstable, being slowly oxidized by air. The ability to accurately and reliably determine the concentration of the active ingredients in various formulations is an important one. In this lab you will determine the content of hydrogen peroxide in a pharmaceutical disinfectant, as well as the concentration of ascorbic acid in Vitamin C supplemental tablets. Both analyses will involve the potentiometric titration of aqueous iodine with sodium thiosulfate using an automatic titrator. A platinum ring indicator electrode is used to follow the progress of the titration curve by potentiometry. Background Titrations Involving Iodine Iodine is a moderately weak oxidizing agent; it is reduced to form the iodide anion, as follows: – – I2(aq) + 2e l 2I (aq) E° = 0.621 V The above redox reaction is completely reversible, and so the iodide anion is a moderately weak reducing agent that will react with oxidizing analytes to produce iodine. Titrations involving iodine have evolved for the analysis of a number of oxidizing and reducing agents. In iodimetric titrations, the analyte (a reducing agent) reacts with iodine to produce iodide: – iodimetry Aox + I2 t Ared + 2I where Aox and Ared are the oxidized and reduced forms, respectively, of the analyte. In iodometric titrations, the analyte (an oxidizing agent) reacts with an unmeasured excess of iodide to produce iodine: – iodometry Ared + 2I t Aox + I2 excess The iodine produced in this reaction is stoichiometrically related to the amount of analyte originally present in the sample.
    [Show full text]
  • Sodium Thiosulfate • This Method Is Called "Iodometry"
    7/20/2010 Iodometric Determination of Copper In US One Cen t Co ins Ma de Be fore an d After 1982 XX YY Pennies are an interesting commodity. They are everywhere , an always present means of currency. The penny is ingrained in our society for many different social and economic reasons. 1 7/20/2010 Penny Composition • Pennies made from 1962 to 1982 consist of 95% copper and 5% zinc. These copper rich pennies are currently worth more as a metal source than their face value. • Pennies minted after 1982 to the present day are only made up of 2.5% copper. This copper is plated onto a zinc core that makes up 97.5% of the penny. • The determination of copper in both pennies made before and after 1982 will be determined using the same method. Introduction to Iodometric Determination 2 7/20/2010 Wet Chemical Analysis • MtdithittlMore accurate and precise than instrumental methods. • Systematic errors have been detected in the past and can be accounted. • More involved process • Help to learn new techniques • Reinforce the techniques learned so far Process selection - Iodine • UdidltUsed widely to quan tittiltitatively measure chemicals reactions • Many analytical procedures are based on the release or uptake • An analyte that is an oxidizing agent is added to excess iodide to produce iodine • The iodine produced is determined by titration with sodium thiosulfate • This method is called "iodometry" 3 7/20/2010 Iodometry • Chosen f or it s st rai ghtf orwar d proce dure • The reaction is rapid and quantitative • The starch used is a clear and determinant indicator • The reagents involved are all easily obtained and in good supply.
    [Show full text]
  • Some Contributions to Iodometric Technique
    University of the Pacific Scholarly Commons University of the Pacific Theses and Dissertations Graduate School 1935 Some contributions to iodometric technique Justin Kimber Dyche University of the Pacific Follow this and additional works at: https://scholarlycommons.pacific.edu/uop_etds Part of the Chemistry Commons Recommended Citation Dyche, Justin Kimber. (1935). Some contributions to iodometric technique. University of the Pacific, Thesis. https://scholarlycommons.pacific.edu/uop_etds/960 This Thesis is brought to you for free and open access by the Graduate School at Scholarly Commons. It has been accepted for inclusion in University of the Pacific Theses and Dissertations by an authorized administrator of Scholarly Commons. For more information, please contact [email protected]. '·~ ' . ' SOME CONTRIBUTIONS TO IODOMETRic- TECID'iiQUE ... ' I by . '/1' 'o ~ '( Justin K: ~yche July, 19'35 .. :• .... ,,.,.· ~· ,.'''. - .. ···-.~~~_:_. I t ~-c_:_:~; ~r 4_; ti1 !~.: ,I, '. ) ' ~ -- t.r ; r~- ' '. : I.. J.' In ~~rtial fulfillm~n~ of the. Requ1rementa for the Degree of Master of Arts ......... __, ..... .,.._ APPROVED: Head of the Department DEPOSITED IN THE COLLEGE LIBRARY: ."-.. '• Librarian ,- DATED: F- .. ,•' r lv - CON'rENTS Section Page I. Obsa-rve.t1ons on Ana.lyll.Jia , • • • • , • • ~ • '· • 3. II. The Eleet~oni~lng Solution. • • • • • • • • t ! t I;t:I. P~eparat1on ot' :mleot:ron1:41n~~SQJ.ut~~on_.__,_._,_t SL_____ _____ IV. Pu.r;Lf'ic~.t.~on of to<tin$ , , , , , , • , • • • • , ~~ v, Standa:rd1r;~tio» q;f Af'«Hmiq So;t,wt;,ion , • , • , , 2~ v~. Oalaulat1ona ' ' , ' I ' ' ' • ' ••••••• ' ~' V+I. Measurements • . ,., ............ VIII, Analytical ~roqe~ur~ , , , , , , , , , • , , , , 4l IX. Electrolytic Determination • • • • ' , ti • • '· 44 X, Summary and Oonolueions , , , , •• , , , , · , 4? Bi bllography .
    [Show full text]
  • Iodimetric Titration of Sulfur Compounds in Alkaline Medium
    Chem. Anal. (Warsaw), 51, 653 (2006) REVIEW Iodimetric Titration of Sulfur Compounds in Alkaline Medium by Witold Ciesielski* and Robert Zakrzewski Department of Instrumental Analysis, University of £ód, ul. Pomorska 163, 90-236 £ód, Poland Keywords: Iodimetric titration; Potentiometry; Coulometry; Thiols; Determination The possibilities of application of iodine as a titrant in determination of sulfur compounds have been presented. The influence of the reaction medium, the nature of compounds, and the thiolthione tautomerism on the reaction stoichiometry of sulfur compounds with iodine has been discussed. The conditions of volumetric titration with visual and potentio- metric end-point detection and coulometric titration with biamperometric end-point detec- tion have been described. The advantages of the applied analytical techniques in the deter- mination of selected sulfur compounds in farmaceutical preparations have been presented. Przedstawiono mo¿liwoci zastosowania jodu jako titrantu do oznaczania zwi¹zków siarki. Omówiono wp³yw rodowiska reakcji, budowy cz¹steczki zwi¹zku oraz tautomerii tioltion na stechiometriê reakcji zwi¹zku siarki z jodem. Opisano warunki zastosowania miareczko- wania objêtociowego z wizualn¹ i potencjometryczn¹ detekcj¹ punktu koñcowego, a tak¿e miareczkowania kulometrycznego z biamperometryczn¹ detekcj¹ punktu koñcowego. Przed- stawiono zalety stosowanych technik analitycznych do oznaczania wybranych zwi¹zków siarki w preparatach farmaceutycznych. * Corresponding author. E-mail: [email protected]; Fax: +48 42 635 58 08 654 W. Ciesielski and R. Zakrzewski Iodine is one of the most popular reagents in a chemical analysis. In iodometry, it is used as a titrant in a direct titration, as well as in the indirect titration, which is based on the reaction between strong oxidizing agents and a large excess of iodide ions to produce iodine in the amount equivalent to the analyte.
    [Show full text]
  • BP102T. PHARMACEUTICAL ANALYSIS (Theory) 45 Hours Scope
    BP102T. PHARMACEUTICAL ANALYSIS (Theory) 45 Hours Scope: This course deals with the fundamentals of analytical chemistry and principles of electrochemical analysis of drugs Objectives: Upon completion of the course student shall be able to understand the principles of volumetric and electro chemical analysis carryout various volumetric and electrochemical titrations develop analytical skills Course Content: UNIT-I 10 Hours (a) Pharmaceutical analysis- Definition and scope i) Different techniques of analysis ii) Methods of expressing concentration iii) Primary and secondary standards. iv) Preparation and standardization of various molar and normal solutions- Oxalic acid, sodium hydroxide, hydrochloric acid, sodium thiosulphate, sulphuric acid, potassium permanganate and ceric ammonium sulphate (b)Errors: Sources of errors, types of errors, methods of minimizing errors, accuracy, precision and significant figures (c)Pharmacopoeia, Sources of impurities in medicinal agents,limit tests. UNIT-II 10 Hours Acid base titration: Theories of acid base indicators, classification of acid base titrations and theory involved in titrations of strong, weak, and very weak acids and bases, neutralization curves Non aqueous titration: Solvents, acidimetry and alkalimetry titration and estimation of Sodium benzoate and Ephedrine HCl UNIT-III 10 Hours Precipitation titrations: Mohr’s method, Volhard’s, Modified Volhard’s, Fajans method, estimation of sodium chloride. Complexometric titration: Classification, metal ion indicators, masking and demasking
    [Show full text]
  • DETERMINATION of VITAMIN C in a PRODUCE PROTECTOR Iodometric Method - TEACHER ​
    DETERMINATION OF VITAMIN C IN A PRODUCE PROTECTOR Iodometric method - TEACHER ​ Since its discovery in the late 1920s1, no other chemical has ever been as celebrated as Vitamin C. The beneficial effect of Vitamin C is almost universally recognized2. It is a water- soluble keto-lactone with two ionizable hydroxyl groups; ascorbate monoanion (Figure - 1), AscH ,​ is the dominant form at physiological pH and is is an ​ excellent reducing agent as well. Research suggest that Vitamin C-rich foods, play an essential role against development of cancer; in addition, plasma concentrations of ascorbate have been shown inversely associated with cancer risk3,4 Figure 1 - ascorbate monoanion ​ ​ . Ascorbate monoanion undergoes two consecutive oxidations to form ascorbate radical (Asc )​ ​ and dehydroascorbic acid (DHA) as shown in Figure 2: Figure 2 - sequence of reactions which Vitamin C undergoes during its oxidation ​ ​ Fruit and vegetables are good sources of vitamin C, and ~90% of the daily intake in the general population comes from these sources. The content varies between species, but citrus fruit, kiwi, mango, and vegetables such as broccoli, tomatoes, and peppers are all rich sources of vitamin C. Since it degrades when heated and during storage, processing and preparation procedures should be considered when estimating dietary intake of vitamin C. In the small intestine, vitamin C reduces dietary iron and allows for efficient transport across the intestinal epithelium. In general, Vitamin C is safe and well tolerated, even in large doses. The U.S. Institute of medicine set the Tolerable Upper Intake Level for oral vitamin C ingestion at 2 g daily for adults.
    [Show full text]
  • IODOMETRY Iodometry Is One of the Most Important Redox Titration Methods. Iodine Reacts Directly, Fast and Quantitively With
    IODOMETRY Iodometry is one of the most important redox titration methods. Iodine reacts directly, fast and quantitively with many organic and inorganic substances. Its to its relatively low, pH independent redox potential, and reversibility of the iodine/iodide reaction, iodometry can be used both to determine amount of reducing agents (by direct titration with iodine) and of oxidizing agents (by titration of iodine with thiosulfate). In all cases the same simple and reliable method of end point detection, based on blue starch complex, can be used. Reversible iodine/iodide reaction mentioned above is - - 2I ↔ I2 + 2e obviously whether it should be treated as oxidation with iodine or reduction with iodides depends on the other redox system involved. Second important reaction used in the iodometry is reduction of iodine with thiosulfate: 2- 2- - 2S2O3 + I2 → S4O6 + 2I In the case of both reactions it is better to avoid low pH. Thiosulfate is unstable in the presence of acids, and iodides in low pH can be oxidized by air oxygen to iodine. Both processes can be source of titration errors. Iodine is very weakly soluble in the water, and can be easily lost from the solution - due to its volatility. However, in the presence of excess iodides iodine creates I3 ions. This lowers free iodine concentration and such solutions are stable enough to be used in lab practice. Still, we should remember that their shelf life is relatively short (they should be kept tightly closed in dark brown bottles, and standardized every few weeks). Iodine solutions are prepared dissolving elemental iodine directly in the iodides solution.
    [Show full text]
  • Iodometry - Wikipedia
    1/25/2021 Iodometry - Wikipedia Iodometry Iodometry, known as iodometric titration, is a method of volumetric chemical analysis, a redox titration where the appearance or disappearance of elementary iodine indicates the end point. Note that iodometry involves indirect titration of iodine liberated by reaction with the analyte, whereas iodimetry involves direct titration using iodine as the titrant. Redox titration using sodium thiosulphate, Na2S2O3 (usually) as a reducing agent is known as iodometric titration since it is used specifically to titrate iodine. The iodometric titration is a general method to determine the concentration of an oxidising agent in solution. In an iodometric titration, a starch solution is used as an indicator since it can absorb the I2 that is released. This absorption will cause the solution to change its colour from deep blue to light yellow when titrated with standardised thiosulfate solution. This indicates the end point of the titration. Iodometry is commonly used to analyze the concentration of oxidizing agents in water samples, such as oxygen saturation in ecological studies or active chlorine in swimming pool water analysis. Contents Basic principles Applications Determination of hydrogensulfites and sulfites Color of iodometric titration mixture before (left) and after (right) the end point Determination of sulfides and hydrogensulfides Determination of hexacyanoferrate(III) References Basic principles To a known volume of sample, an excess but known amount of iodide is added, which the oxidizing agent
    [Show full text]
  • 37G Titrations with Iodine 1087
    37G Titrations with Iodine 1087 37G TITRATIONS WITH IODINE The oxidizing properties of iodine, the composition and stability of triiodide solu- tions, and the applications of this reagent in volumetric analysis are discussed in Section 20C-3. Starch is ordinarily employed as an indicator for iodometric titrations. 37G-1 Preparation of Reagents PROCEDURE (a) Iodine approximately 0.05 M. Weigh about 40 g of KI into a 100-mL beaker. Add 12.7 g of I2 and 10 mL of water. Stir for several minutes (Note 1). Intro- duce an additional 20 mL of water, and stir again for several minutes. Care- fully decant the bulk of the liquid into a storage bottle containing 1 L of distilled water. It is essential that any undissolved iodine remain in the beaker (Note 2). (b) Starch indicator (sufficient for about 100 titrations). Rub 1 g of soluble starch and 15 mL of water into a paste. Dilute to about 500 mL with boiling water, and heat until the mixture is clear. Cool; store in a tightly stoppered bottle. For most titrations, 3 to 5 mL of the indicator are used. The indicator is readily attacked by airborne organisms and should be freshly prepared every few days. Notes 1. Iodine dissolves slowly in the KI solution. Thorough stirring is needed to hasten the process. 2. Any solid I2 inadvertently transferred to the storage bottle will cause the con- centration of the solution to increase gradually. Filtration through a sintered- glass crucible eliminates this potential source of difficulty. 37G-2 Standardization of Iodine Solutions Discussion Arsenic(III) oxide, long a favored primary standard for iodine solutions, is now sel- dom used because of the elaborate federal regulations governing the use of even small amounts of arsenic-containing compounds.
    [Show full text]