Sensor and Thermostat Selection Fundamentals
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Installation Guide
Installation guide Welcome! If you have questions, we have answers. Visit ecobee.com/Support/ecobee3 for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone: [email protected] 1.877.932.6233 (North America) 1.647.428.2220 (International) Compatible systems ecobee3 works with most centralized residential heating and cooling systems. Heating: up to 2 stages Cooling: up to 2 stages Heat pumps: 1 or 2 stages + up to 2 stages auxiliary heat Accessories: Dehumidifier, humidifier or ventilation device 3 Items included in box A ecobee3 thermostat with D Large trim plate back plate and trim plate E Screws and drywall plugs B Remote Sensor and stand F Information booklets C Power Extender Kit G Double-sided adhesives (optional) A B C wire labels Installation Guide Quick Start Guide D E F G 4 Items you’ll need A Phillips screwdriver B Drill for mounting anchors with 3⁄₁₆ inch drill bit A B Tip: Review all the instructions before you start to ensure that there are no surprises during installation. Tip: For accurate temperature readings, install your ecobee3 in a conditioned space, on an interior wall, and away from direct heat sources. 5 Overview of steps Installing your ecobee3 home climate system is easy. Just follow these steps and you’ll be done before you know it. Step 1 Power off your HVAC system page 8 Before doing anything else, power off your system. Step 2 Label the wires page 9 Label each wire with the provided stickers. Step 3 Install Power Extender Kit page 11 The PEK is not required for all installs. -
Add More Flexibility to Building Automation with New Communicating Thermostats More Choices
Communicating Thermostats Add More Flexibility to Building Automation with New Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between, Honeywell’s lineup of TB7600, TB7300 and TB7200 Series communicating thermostats deliver fully integrated functionality. All work seamlessly with WEBs-AX™, giving you more flexibility to serve more applications. Features of all TB7600, TB7300 • BACnet® MS/TP and ZigBee® wireless mesh protocols and TB7200 Series • Backlit LCD display communicating • Fully integrated advanced occupancy thermostats include: functionality with passive infra-red (PIR) models; all models are PIR occupancy sensor ready with the addition of the occupancy sensor cover • Password protection to minimize • Support for single or dual setpoints and up parameter tampering to three setpoints on some models • Multi-level keypad lockout • Set display for °F or °C • Local menu-driven configuration • PI control with adjustable proportional band • Configurable control sequences • Removable terminal blocks and hinged PCB • Up to three programmable digital inputs board to simplify wiring and installation • Multifunction auxiliary output TB7600 Series For Rooftop and Heat Pump TB7600 Series Communicating RTU/Heat Pump Thermostats OS NUMBER DESCRIPTION NETWORK OUTPUTS SCHEDULING PIR TB7600A5014B Single Stage RTU BACnet 1H/1C No Ready TB7600A5514B Single Stage RTU BACnet 1H/1C No Yes TB7600B5014B Multi-stage RTU BACnet 2H/2C No Ready TB7600B5514B Multi-stage RTU BACnet 2H/2C -
Smart Buildings: Using Smart Technology to Save Energy in Existing Buildings
Smart Buildings: Using Smart Technology to Save Energy in Existing Buildings Jennifer King and Christopher Perry February 2017 Report A1701 © American Council for an Energy-Efficient Economy 529 14th Street NW, Suite 600, Washington, DC 20045 Phone: (202) 507-4000 • Twitter: @ACEEEDC Facebook.com/myACEEE • aceee.org SMART BUILDINGS © ACEEE Contents About the Authors ..............................................................................................................................iii Acknowledgments ..............................................................................................................................iii Executive Summary ........................................................................................................................... iv Introduction .......................................................................................................................................... 1 Methodology and Scope of This Study ............................................................................................ 1 Smart Building Technologies ............................................................................................................. 3 HVAC Systems ......................................................................................................................... 4 Plug Loads ................................................................................................................................. 9 Lighting .................................................................................................................................. -
Icomfort S30 Smart Thermostat Installation and Setup Guide
iComfort® S30 Smart Thermostat Installation and Setup Guide Color Touchscreen Programmable Wi-Fi Communicating Thermostat (12U67) 507536-02 5/2017 Supersedes 10/2016 Software Version 3.2 TABLE OF CONTENTS SHIPPING AND PACKING LIST ............................................. 3 Mag-Mount....................................................... 33 GENERAL ................................................................. 3 Add / Remove Equipment........................................... 33 INSTALLING CONTROL SYSTEM COMPONENTS ............................. 4 Reset ............................................................ 33 Smart Hub Installation................................................... 4 Notifications ........................................................... 33 Mag-Mount Installation.................................................. 5 Tests ................................................................. 33 HD Display External Components......................................... 6 Diagnostics ............................................................ 33 HD Display Installation.................................................. 6 Installation Report...................................................... 33 WIRING FOR CONTROL SYSTEM COMPONENTS............................. 7 Information ............................................................ 34 CONFIGURATING HEAT SECTIONS ON AIR HANDLER CONTROL.............. 12 Dealer — Information............................................... 34 SMART HUB OPERATIONS................................................ -
Building Automation – Impact on Energy Efficiency
Building automation – impact on energy efficiency Application per EN 15232:2012 eu.bac product certification Answers for infrastructure. Contents 1 Introduction .............................................................................................5 1.1 Use, targets and benefits ..........................................................................5 1.2 What constitutes energy efficiency? .........................................................6 2 Global situation: energy and climate....................................................7 2.1 CO2 emissions and global climate ............................................................7 2.2 Primary energy consumption in Europe....................................................8 2.3 Turning the tide – a long-term process .....................................................8 2.4 Reduce energy usage in buildings............................................................9 2.5 Siemens contribution to energy savings ................................................. 11 3 Building automation and control system standards.........................13 3.1 EU measures ..........................................................................................13 3.2 The standard EN 15232..........................................................................17 3.3 eu.bac certification ..................................................................................19 3.4 Standardization benefits..........................................................................19 4 The EN 15232 standard -
Dodge Cummins Coolant Bypass
FPE-2018-06 SUBJECT: DODGE CUMMINS COOLANT BYPASS KIT November, 2020 Page 1 of 6 FITMENT: 2003–2007 Dodge Cummins Manual Transmission Only 2007.5-2018 Dodge Cummins Manual and Automatic Transmissions KIT P/N: FPE-CLNTBYPS-CUMMINS-MAN, FPE-CLNTBYPS-CUMMINS-6.7 ESTIMATED INSTALLATION TIME: 2-3 Hours TOOLS REQUIRED: 16mm ratcheting wrench, 10mm socket, 8mm socket, 6mm Allen, 1” wrench, hammer, 5-gallon clean drain pan, 36” pry bar, Scotch-Brite TM pad (included in kit). KIT CONTENTS: Item Description Qty 1 Coolant bypass hose 1 2 Coolant bypass thermostat housing 1 and O-ring 3 Thermostat riser block and O-ring 1 3 4 4 Coolant bypass hose riser bracket 2 2 5 M8 x 1.25, 20mm socket head cap 2 screw 7 6 6 M6 x 1.00 x 60mm flange head bolt 3 5 7 M12 x 1.75, 40mm flange head bolt 2 8 Scotch-Brite TM pad (not pictured) 1 1 WARNINGS: • Use of this product may void or nullify the vehicle’s factory warranty. • User assumes sole responsibility for the safe & proper use of the vehicle at all times. • The purchaser and end user releases, indemnifies, discharges, and holds harmless Fleece Performance Engineering, Inc. from any and all claims, damages, causes of action, injuries, or expenses resulting from or relating to the use or installation of this product that is in violation of the terms and conditions on this page, the product disclaimer, and/or the product installation instructions. Fleece Performance Engineering, Inc. will not be liable for any direct, indirect, consequential, exemplary, punitive, statutory, or incidental damages or fines cause by the use or installation of this product. -
Lonworks® Platform Revision 2
Introduction to the LonWorks® Platform revision 2 ® 078-0183-01B Echelon, LON, LonWorks, LonMark, NodeBuilder, , LonTalk, Neuron, 3120, 3150, LNS, i.LON, , ShortStack, LonMaker, the Echelon logo, and are trademarks of Echelon Corporation registered in the United States and other countries. LonSupport, , , OpenLDV, Pyxos, LonScanner, LonBridge, and Thinking Inside the Box are trademarks of Echelon Corporation. Other trademarks belong to their respective holders. Neuron Chips, Smart Transceivers, and other OEM Products were not designed for use in equipment or systems which involve danger to human health or safety or a risk of property damage and Echelon assumes no responsibility or liability for use of the Neuron Chips in such applications. Parts manufactured by vendors other than Echelon and referenced in this document have been described for illustrative purposes only, and may not have been tested by Echelon. It is the responsibility of the customer to determine the suitability of these parts for each application. ECHELON MAKES AND YOU RECEIVE NO WARRANTIES OR CONDITIONS, EXPRESS, IMPLIED, STATUTORY OR IN ANY COMMUNICATION WITH YOU, AND ECHELON SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Echelon Corporation. Printed in the United States of America. Copyright -
And Tec220x-4(+PIR) Series LONWORKS Network Staged Thermostat Controllers
TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Code No. LIT-12011611 Technical Bulletin Issued February 8, 2010 Network Variables (NVs) and Configuration Parameters (CPs) List. 3 Network Variable Inputs (NVIs) Table . 8 Network Variable Outputs (NVOs) Table . 10 Configuration Properties (CPs) . 13 Space Comfort Controller Object . 18 Commissioning the Thermostat Using a LONWORKS Network Configuration Tool . 18 Service Pin . 19 TEC22xx-4 Configuration Plug-in. 19 Installing the Plug-in. 19 Registering the Plug-in. 20 Using LN Browser to Display NVs, NCIs, and CPs . 22 Running the Plug-in . 27 Heating - Cooling Tab . 31 Hardware Tab . 32 General Tab . 33 Model Tab . 34 Scheduler Tab . 36 Network Tab . 38 About Tab . 39 Adding a Thermostat to the Network Automation Engine (NAE) . 39 LONWORKS Thermostat Controller Mapping . 40 Preparation . 40 Troubleshooting Guide . 40 Technical Specifications . 43 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS Network Staged Thermostat Controllers . 43 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged 1 Thermostat Controllers Technical Bulletin 2 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Technical Bulletin TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Technical Bulletin Network Variables (NVs) and Configuration Parameters (CPs) List Table 1 shows the NVs and CPs for the TEC226x-4(+PIR) and TEC220x-4(+PIR) Series Thermostat Controllers. Each Network Variable Input (NVI), Network Variable Output (NVO), and Network Configuration Input (NCI) has a reference number as defined in the XIF Resource File, and some objects have a subcategory number. -
Room Humidistat and Thermostat Combination, Wall Mounting, For
Room humidistat and thermostat combination, wall mounting, for swimming pools areas and air conditioning Type Q4 DIMENSIONS MAIN FEATURES Main Application: This device is a combination of a humidistat and a room thermostat. It is especially suited for use in air conditioning control of indoor swimming-pool halls.His aesthetics and small size housing (122x70x31mm) allows mounting in most of these applications, but must be protected from splashing water, and used only in ambient air free of chemical contamination or corrosive ingredients. It is designed to turn on heating or cooling, ventilation, humidifiers, dehumidifiers, and heat pumps. It must be vertically wall mounted in a naturally ventilated area Humidity sensing element: hygroscopic polymer film with special treatment, produced by Ultimheat, ensuring a fast response, long life and high stability Humidity setting range: 35 to 95% RH Humidity measuring accuracy: ±5% RH Differential at 50% RH: 8% RH (±3% RH ) Measuring medium: air, pressure-less, non-aggressive Electrical contact: silver contacts, SPDT, 5A 250V, res. For use in humidifier, dehumidifier or ventilation control. Maintenance: The humidity sensing ribbon is maintenance-free in clean air. Air containing solvent can cause measuring errors and failure, depending on the type and concentration. Deposits such as resin aerosols, lacquer aerosols, smokes, which eventually form a water-repellent film are harmful for the measuring element. Temperature measuring element: Bimetal strip Temperature adjustment range: 5-35°C Differential: 0.6+/-0.3°C Electrical contact: silver contacts, SPDT, 5A 250V, res. For use in heating or cooling applications Options: • On Off switch • Thermal anticipator, that provides thermal differential reduction (Needs Neutral+ Line power supply, 230 or 24V) • Remote set point reduction (Needs Neutral+ Line power supply, 230 or 24V) • Temperature printings in °F Connection: screw terminal connection block for 1.5mm² wires, max torque 0.5Nm Mounting: wall mounting, with 2 screws dia 4 mm max, distance 100 x 50 mm. -
Installation, Setup & Troubleshooting Supplement
EconoMi$er X F a c t o r y --- I n s t a l l e d O p t i o n Low Leak Economizer for 2 Speed SAV (Staged Air Volume) Systems Installation, Setup & Troubleshooting Supplement This document is a supplemental installation instruction for the factory-installed EconoMi$er X (low leak economizer) option. It is to be used with the base unit Installation Instructions for 48/50TC, 50TCQ, 48/50HC, and 50HCQ 2-Stage cooling units, sizes 08 – 30. Units equipped with the EconoMi$er X option are identified by an indicator in the unit's model number (see the unit's nameplate). Use Table 1 (on page 2) to identify whether or not a given unit is equipped with the factory-installed EconoMi$er X. NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS SAFETY CONSIDERATIONS SAFETY CONSIDERATIONS.................... 1 Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical GENERAL.................................... 2 shock or other conditions which may cause personal injury Identifying Factory Option...................... 2 or property damage. Consult a qualified installer, service EconoMi$er X................................ 3 agency, or your distributor or branch for information or assistance. The qualified installer or agency must use W7220 Economizer Controller................... 3 factory--authorized kits or accessories when modifying this User Interface................................ 3 product. Refer to the individual instructions packaged with Menu Structure............................... 3 the kits or accessories when installing. Checkout Tests............................... 7 Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations and SETUP AND CONFIGURATION................ -
SOLAR HEATING CONTROLS by Radiantec Company
SOLAR HEATING CONTROLS by Radiantec Company THE SOLAR CONTROL LOOP Solar Loop Control Sensors Solar Control (cover off) OPERATION- The solar loop control turns on the solar loop pump whenever solar energy is available and turns the pump off when sufficient solar energy is no longer available. (See the appendix for a detailed dis- cussion of control operation) CONTROLLER LOGIC- The solar loop control is a “differential temperature control”. It senses temperature at two locations and operates according to the difference between the temperatures at these two locations. When the temperature of the “collector” sensor is 8° F warmer, or more, than the “storage/tank” sensor, the output switch is closed. (that action turns the pump on) When the temperature of the “collector” sensor is only 4° F, or less, warmer than the “storage/tank” sensor, the output switch is opened.(That action turns the pump off ) SENSOR PLACEMENT - Place the “collector” sensor on the outlet pipe of the solar collector array and insulate well. Place the “storage” sensor on the pipe at the point where the flow from the heat exchangers come together in one pipe for return to the solar collectors. Insulate well. See page 16 of the installation manual for sensor placement details. Typical Control Setting Turn on = 8° Hi limit = 200° Optional Temperature Display SOLAR HEATING CONTROLS by Radiantec Company HEAT DUMP CONTROL Heat Dump Valve Place the heat dump valve in any hot water line and plumb to a suitable drain. Laundry room placement can be convenient. Setpoint Control Setpoint Control (cover off) OPERATION - The heat dump control lowers system temperature by automatically consuming some domestic hot water whenever excessive temperatures are detected. -
Viega Digital Thermostat
User Guide Viega Digital Thermostat Features ■ Compact Design ■ Digital LCD Display ■ Regulates Floor or Room Temperature ■ Optional Floor Sensor ■ Setback Function ■ On / Off Switch Specifications ■ Control: Microprocessor control ■ Accuracy: 0.1°F ■ Set Temperature Range: 41 °F - 99 °F, 0.5 °F increments This document is subject to updates. ■ Environment Range: 32 °F - 122 °F For the most current Viega technical ■ Power Supply: 24 VAC +/_ 10% literature please visit www.viega.us. 60Hz 15 W max ■ Output: TRIAC output 24 Viega products are designed to be VAC, 15 W max installed by licensed and trained ■ Optional Floor Sensor: NTC thermistor plumbing, mechanical, and electrical (10K Ohms), 10 cable professionals who are familiar with Viega ■ Floor limiting range: 41°F - 98.6°F products and their installation. Installation ■ Electrical Protection: Class II - IP30 by non-professionals may void Viega LLC’s 2.60" warranty. Applications The digital thermostat is ideal for individual room temperature control. A user-friendly, three- button design allows for easy adjustment of settings. The thermostat can sense either room temperature or floor temperature. Adjustable temperature setback function allows for energy savings. The thermostat can control up to four 1.22" 3.15" powerheads directly or can be connected to a zone / circulator control box. With optional floor sensor, the thermostat provides floor high or low limit function for floor protection or floor warming. UG-HC 560621 0120 Digital Thermostat (EN) 1 of 8 Viega Digital Thermostat User Guide Installation ■ Remove oval rubber plug from front of °F °C thermostat faceplate. ■ Using a small Phillips screwdriver remove screw securing thermostat faceplate to Cover Screw mounting plate.