Switchgear and Protective Devices 2015
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Chapter – 3 Electrical Protection System
CHAPTER – 3 ELECTRICAL PROTECTION SYSTEM 3.1 DESIGN CONSIDERATION Protection system adopted for securing protection and the protection scheme i.e. the coordinated arrangement of relays and accessories is discussed for the following elements of power system. i) Hydro Generators ii) Generator Transformers iii) H. V. Bus bars iv) Line Protection and Islanding Primary function of the protective system is to detect and isolate all failed or faulted components as quickly as possible, thereby minimizing the disruption to the remainder of the electric system. Accordingly the protection system should be dependable (operate when required), secure (not operate unnecessarily), selective (only the minimum number of devices should operate) and as fast as required. Without this primary requirement protection system would be largely ineffective and may even become liability. 3.1.1 Reliability of Protection Factors affecting reliability are as follows; i) Quality of relays ii) Component and circuits involved in fault clearance e.g. circuit breaker trip and control circuits, instrument transformers iii) Maintenance of protection equipment iv) Quality of maintenance operating staff Failure records indicate the following order of likelihood of relays failure, breaker, wiring, current transformers, voltage transformers and D C. battery. Accordingly local and remote back up arrangement are required to be provided. 3.1.2 Selectivity Selectivity is required to prevent unnecessary loss of plant and circuits. Protection should be provided in overlapping zones so that no part of the power system remains unprotected and faulty zone is disconnected and isolated. 3.1.3 Speed Factors affecting fault clearance time and speed of relay is as follows: i) Economic consideration ii) Selectivity iii) System stability iv) Equipment damage 3.1.4 Sensitivity Protection must be sufficiently sensitive to operate reliably under minimum fault conditions for a fault within its own zone while remaining stable under maximum load or through fault condition. -
INNOVATIVE NUMERICAL PROTECTION RELAY DESIGN on the BASIS of SAMPLED MEASURED VALUES for SMART GRIDS Christophe Ghafari
INNOVATIVE NUMERICAL PROTECTION RELAY DESIGN ON THE BASIS OF SAMPLED MEASURED VALUES FOR SMART GRIDS Christophe Ghafari To cite this version: Christophe Ghafari. INNOVATIVE NUMERICAL PROTECTION RELAY DESIGN ON THE BASIS OF SAMPLED MEASURED VALUES FOR SMART GRIDS. Electric power. Université Grenoble Alpes, 2016. English. tel-01570127 HAL Id: tel-01570127 https://hal.archives-ouvertes.fr/tel-01570127 Submitted on 28 Jul 2017 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. THÈSE Pour obtenir le grade de DOCTEUR DE LA COMMUNAUTÉ UNIVERSITÉ GRENOBLE ALPES Spécialité : Génie Électrique Arrêté ministériel : 7 août 2006 Présentée par Christophe GHAFARI Thèse dirigée par Nouredine HADJSAID et codirigée par Raphaël CAIRE et Bertrand RAISON préparée au sein du Laboratoire G2Elab dans l'École Doctorale EEATS Innovative Numerical Protection Relay Design on the basis of Sampled Measured Values for Smart Grids Thèse soutenue publiquement le 16 décembre 2016 , devant le jury composé de : M. Lars NORDSTROM Rapporteur, Professor, Royal Institute of Technology, Sweden M. Désiré Dauphin RASOLOMAMPIONONA Président, Professor, Warsaw University of Technology, Poland M. Peter CROSSLEY Examinateur, Professor, University of Manchester, United Kingdom M. Carlo Alberto NUCCI Examinateur, Professor, University of Bologna, Italy M. -
Application Guidelines for Ground Fault Protection
Application Guidelines for Ground Fault Protection Joe Mooney and Jackie Peer Schweitzer Engineering Laboratories, Inc. Presented at the 1998 International Conference Modern Trends in the Protection Schemes of Electric Power Apparatus and Systems New Delhi, India October 28–30, 1998 Previously presented at the 52nd Annual Georgia Tech Protective Relaying Conference, May 1998 Originally presented at the 24th Annual Western Protective Relay Conference, October 1997 APPLICATION GUIDELINES FOR GROUND FAULT PROTECTION Joe Mooney, P.E., Jackie Peer Schweitzer Engineering Laboratories, Inc. INTRODUCTION Modern digital relays provide several outstanding methods for detecting ground faults. New directional elements and distance polarization methods make ground fault detection more sensitive, secure, and precise than ever. Advances in communications-aided protection further advance sensitivity, dependability, speed, and fault resistance coverage. The ground fault detection methods and the attributes of each method discussed in this paper are: • Directional Zero-Sequence Overcurrent • Directional Negative-Sequence Overcurrent • Quadrilateral Ground Distance • Mho Ground Distance Comparison of the ground fault detection methods is on the basis of sensitivity and security. The advantages and disadvantages for each method are presented and compared. Some problem areas of ground fault detection are discussed, including system nonhomogeneity, zero-sequence mutual coupling, remote infeed into high-resistance faults, and system unbalances due to in-line switching. Design and application considerations for each problem area are given to aid in setting the relay elements correctly. This paper offers a selection and setting guide for ground fault detection on noncompensated overhead power lines. The setting guide offers support in selecting the proper ground fault detection element based upon security, dependability, and sensitivity (high-resistance fault coverage). -
Upgrading Power System Protection to Improve Safety, Monitoring, Protection, and Control
Upgrading Power System Protection to Improve Safety, Monitoring, Protection, and Control Jeff Hill Georgia-Pacific Ken Behrendt Schweitzer Engineering Laboratories, Inc. Presented at the Pulp and Paper Industry Technical Conference Seattle, Washington June 22–27, 2008 Upgrading Power System Protection to Improve Safety, Monitoring, Protection, and Control Jeff Hill, Georgia-Pacific Ken Behrendt, Schweitzer Engineering Laboratories, Inc. Abstract—One large Midwestern paper mill is resolving an shown in Fig. 1 and Fig. 2, respectively. Each 5 kV bus in the arc-flash hazard (AFH) problem by installing microprocessor- power plant is supplied from two 15 kV buses. All paper mill based (μP) bus differential protection on medium-voltage and converting loads are supplied from either the 15 kV or switchgear and selectively replacing electromechanical (EM) overcurrent relays with μP relays. In addition to providing 5 kV power plant buses. Three of the power plant’s buses critical bus differential protection, the μP relays will provide utilized high-impedance bus differential relays installed during analog and digital communications for operator monitoring and switchgear upgrades within the last eight years. control via the power plant data and control system (DCS) and The generator neutral points are not grounded. Instead, a will ultimately be used as the backbone to replace an aging 15 kV zigzag grounding transformer had been installed on one hardwired load-shedding system. of the generator buses, establishing a low-impedance ground The low-impedance bus differential protection scheme was source that limits single-line-to-ground faults to 400 A. Each installed with existing current transformers (CTs), using a novel approach that only required monitoring current on two of the of the 5 kV bus source transformers is also low-impedance three phases. -
Innovative Numerical Protection Relay Design on the Basis of Sampled Measured Values for Smartgrids Christophe Ghafari
Innovative numerical protection relay design on the basis of sampled measured values for smartgrids Christophe Ghafari To cite this version: Christophe Ghafari. Innovative numerical protection relay design on the basis of sampled mea- sured values for smartgrids. Electric power. Université Grenoble Alpes, 2016. English. NNT : 2016GREAT113. tel-01819664 HAL Id: tel-01819664 https://tel.archives-ouvertes.fr/tel-01819664 Submitted on 20 Jun 2018 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. THÈSE Pour obtenir le grade de DOCTEUR DE L’UNIVERSITÉ GRENOBLE ALPES Spécialité : Génie Electrique Arrêté ministériel : 7 août 2006 Présentée par Christophe GHAFARI Thèse dirigée par Nouredine HADJSAID et co-encadrée par Raphaël CAIRE et Bertrand RAISON préparée au sein du G2ELab dans l'École Doctorale EEATS Innovative Numerical Protection Relay Design on the basis of Sampled Measured Values for Smart Grids Thèse soutenue publiquement le 16 Décembre 2016, devant le jury composé de M. Lars NORDSTROM Rapporteur, Professor, Royal Institute of Technology, Sweden M. Désiré Dauphin RASOLOMAMPIONONA Président, Professor, Warsaw University of Technology, Poland M. Peter CROSSLEY Examinateur, Professor, University of Manchester, United Kingdom M. Carlo Alberto NUCCI Examinateur, Professor, University of Bologna, Italy M. -
Experimental Study of Numerical Relay for Over-Current Protection in Solar Panel for Securing the Hydrogen Production
E3S Web of Conferences 61, 00005 (2018) https://doi.org/10.1051/e3sconf/2018610000 5 ICREN 2018 Experimental Study of Numerical Relay for Over-current Protection in Solar Panel for Securing the Hydrogen production. Chawki Ameur menad1,*, M. Bouchahdane2, and Rabah Gomri1 1University Frères Mentouri Constantine 1, Faculty of Sciences and Technology, Department of Génie Climatique, 25000 Constatine, Algeria 2Department of Power and control Institute of Electrical and Electronic Engineering, IGEE Boumerdes, Algeria Abstract.. Every electrical system in solar panel can fail during electrical faults. In this incidence, high fault current can occur. Such current must be interrupted by a protective system. The research was supported by experimental tests. In work conditions close to real, the numerical relay REF542plus was tested for both instantaneous and extremely inverse definite minimum time IDMT over-current protection functions with the help of CMC 365 injection and test equipment associated to Test Universe software. Protecting hybrid solar panels generating by different renewable energy sources for hydrogen production from over-current is very important for improving the energy efficiency in one hand, and securing the function in critical condition from damage of the solar cells in second hand. The contribution of this research is controlling the over-current in the solar panel for securing the continuation of the hydrogen production from renewable energy sources in short time. The obtained results allowed the observation of the relay’s behavior when subjected to certain faults; where the solar panel keeps producing the hydrogen. 1 INTRODUCTION Due to the impact of the safety in solar systems on the energy efficiency in critical situation, an experimental proposal research project was studied for understanding the most important problem which is the over-current in solar systems in Algerian Climate. -
Transformer Protection
Power System Elements Relay Applications PJM State & Member Training Dept. PJM©2018 6/05/2018 Objectives • At the end of this presentation the Learner will be able to: • Describe the purpose of protective relays, their characteristics and components • Identify the characteristics of the various protection schemes used for transmission lines • Given a simulated fault on a transmission line, identify the expected relay actions • Identify the characteristics of the various protection schemes used for transformers and buses • Identify the characteristics of the various protection schemes used for generators • Describe the purpose and functionality of Special Protection/Remedial Action Schemes associated with the BES • Identify operator considerations and actions to be taken during relay testing and following a relay operation PJM©2018 2 6/05/2018 Basic Concepts in Protection PJM©2018 3 6/05/2018 Purpose of Protective Relaying • Detect and isolate equipment failures ‒ Transmission equipment and generator fault protection • Improve system stability • Protect against overloads • Protect against abnormal conditions ‒ Voltage, frequency, current, etc. • Protect public PJM©2018 4 6/05/2018 Purpose of Protective Relaying • Intelligence in a Protective Scheme ‒ Monitor system “inputs” ‒ Operate when the monitored quantity exceeds a predefined limit • Current exceeds preset value • Oil level below required spec • Temperature above required spec ‒ Will initiate a desirable system event that will aid in maintaining system reliability (i.e. trip a circuit -
Protection, Control, Automation, and Integration for Off-Grid Solar-Powered Microgrids in Mexico
Protection, Control, Automation, and Integration for Off-Grid Solar-Powered Microgrids in Mexico Carlos Eduardo Ortiz and José Francisco Álvarez Rada Greenergy Edson Hernández, Juan Lozada, Alejandro Carbajal, and Héctor J. Altuve Schweitzer Engineering Laboratories, Inc. Published in Wide-Area Protection and Control Systems: A Collection of Technical Papers Representing Modern Solutions, 2017 Previous revised edition released October 2013 Originally presented at the 40th Annual Western Protective Relay Conference, October 2013 1 Protection, Control, Automation, and Integration for Off-Grid Solar-Powered Microgrids in Mexico Carlos Eduardo Ortiz and José Francisco Álvarez Rada, Greenergy Edson Hernández, Juan Lozada, Alejandro Carbajal, and Héctor J. Altuve, Schweitzer Engineering Laboratories, Inc. Abstract—Comisión Federal de Electricidad (CFE), the distribution network. Each microgrid includes an integrated national Mexican electric utility, launched the White Flag protection, control, and monitoring (PCM) system. The Program (Programa Bandera Blanca) with the objective of system collects and processes data from the microgrid providing electricity to rural communities with more than 100 inhabitants. In 2012, CFE launched two projects to provide substations and sends the data to the supervisory control and electric service to two communities belonging to the Huichol data acquisition (SCADA) master of two remote CFE control indigenous group, Guásimas del Metate and Tierra Blanca del centers. The system includes local and remote controls to Picacho, which are both located in the mountains near Tepic, operate the microgrid breaker. Nayarit, Mexico. Each microgrid consists of a photovoltaic power CFE is studying the possibility of interconnecting plant, a step-up transformer bank, and a radial medium-voltage neighboring microgrids in the future to improve service distribution network. -
Electrical Control and Protection System of Geothermal Power Plants
Orkustofnun, Grensasvegur 9, Reports 2014 IS-108 Reykjavik, Iceland Number 13 ELECTRICAL CONTROL AND PROTECTION SYSTEM OF GEOTHERMAL POWER PLANTS Daniel Gorfie Beyene Ethiopian Electric Power Company P.O. Box 1233 Addis Ababa ETHIOPIA [email protected] ABSTRACT This study explores the use of electrical controls and a protection system in a geothermal power plant for smooth and reliable operation of the plant. Geothermal power is a renewable energy and is also used as a baseload for the supply of electricity in the grid. To fulfil this goal, great measures must be taken in the selection of electrical protection equipment for the different electrical components, such as the transformer and the generator, as described in the report. A geothermal power plant must also be furnished with a proper control system for controlling different components of the plant such as the turbine, the generator, the transformer, the excitation system and other related accessories so that when some abnormal condition occurs in the system, proper action can be taken. 1. INTRODUCTION Energy is one of the most fundamental elements of our universe. The significance of energy is especially vital for developing countries like Ethiopia. On-demand energy in the form of electricity and modern fuels is the lifeblood of modern civilization and is a critical factor for economic development and employment. In 2013, the total installed capacity of electrical power in Ethiopia was more than 2,200 MW, mainly from hydro power plants, with some help from wind and a small pilot geothermal power plant. Ethiopia launched a long-term geothermal exploration undertaking in 1969. -
Loss of Mains (ROCOF)
Assessment of Risks Resulting from the Adjustment of ROCOF Based Loss of Mains Protection Settings Phase II Authors Dr Adam Dyśko Dimitrios Tzelepis Dr Campbell Booth This work was commissioned by the Energy Networks Association and prepared for the workgroup “Frequency changes during large system disturbances” (GC0079) October 2015 Institute for Energy and Environment Department of Electronic and Electrical Engineering University of Strathclyde Glasgow REF: ENA/LOM/TR/2015-001 Table of Contents Abbreviations and symbols ......................................................................................................................3 1 Executive Summary .........................................................................................................................4 2 Introduction .....................................................................................................................................6 2.1 Methodology ............................................................................................................................6 3 WP2 – Simulation based assessment of NDZ ..................................................................................8 3.1 Network modelling ...................................................................................................................8 3.2 DG Models and Controls ...........................................................................................................8 3.2.1 Synchronous Generator ....................................................................................................9 -
A Novel Busbar Protection Based on the Average Product of Fault Components
energies Article A Novel Busbar Protection Based on the Average Product of Fault Components Guibin Zou 1,* ID , Shenglan Song 2, Shuo Zhang 1 ID , Yuzhi Li 2 and Houlei Gao 1 1 Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Jinan 250000, China; [email protected] (S.Z.); [email protected] (H.G.) 2 State Grid Weifang Power Supply Company, Weifang 261000, China; [email protected] (S.S.); [email protected] (Y.L.) * Correspondence: [email protected]; Tel.: +86-135-0541-6354 Received: 13 March 2018; Accepted: 1 May 2018; Published: 3 May 2018 Abstract: This paper proposes an original busbar protection method, based on the characteristics of the fault components. The method firstly extracts the fault components of the current and voltage after the occurrence of a fault, secondly it uses a novel phase-mode transformation array to obtain the aerial mode components, and lastly, it obtains the sign of the average product of the aerial mode voltage and current. For a fault on the busbar, the average products that are detected on all of the lines that are linked to the faulted busbar are all positive within a specific duration of the post-fault. However, for a fault at any one of these lines, the average product that has been detected on the faulted line is negative, while those on the non-faulted lines are positive. On the basis of the characteristic difference that is mentioned above, the identification criterion of the fault direction is established. Through comparing the fault directions on all of the lines, the busbar protection can quickly discriminate between an internal fault and an external fault. -
100 Years of Relay Protection, the Swedish ABB Relay History
100 years of relay protection, the Swedish ABB relay history By Bertil Lundqvist ABB Automation Products, Substation Automation Division (Sweden) INTRODUCTION The ABB relay protection and substation automation history goes back to the turn of the previous century. The first protection relay type TCB was developed in the early years of 1900. The first installation was made in 1905. By 1925, a remote controlled station was put into operation. ABB has delivered many millions protection and control devices throughout the world. Through the years ABB has introduced a great number of leading innovations within the protection and control field. The development was from the beginning made with a national perspective, but very early a global perspective was introduced when designing relay and control equipment. The development can be divided in three main stages; the first stage was the era of electromechanical relays, which started over 100 years ago. The next era was static or electronic relays, which were introduced in the 1960s. The present era with microprocessor based relays started in the beginning of the 1980s, where microprocessor performed the logics, but the filtering was analogue. The first fully numerical relay was introduced 1986. 1. GENERAL • 1940 Harmonic restraint transformer- The technological history in Protection and Station differential Automation can be shown comparing space requirements between modern and old equipment. One • 1950 Compensator poly-phase distance relay numerical terminal can replace up two five panels with