Kimball Labs
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Tau-100 Test Report S/N: 02280382
TAU-100 TEST REPORT S/N: 02280382 Prepared by: Aaron Sivacoe Date: April 8, 2005 Contents Contents ____________________________________________________________________ 2 Test Equipment______________________________________________________________ 3 Performance Specifications ____________________________________________________ 4 Visual Power Output Rating ___________________________________________________ 4 Visual Power Adjustment Capability ____________________________________________ 5 Aural Power Output Rating ___________________________________________________ 6 Carrier Frequency Tolerance __________________________________________________ 8 Visual Frequency Response __________________________________________________ 11 Intermodulation Distortion ___________________________________________________ 14 Spurious Emissions_________________________________________________________ 16 Modulation _______________________________________________________________ 18 K Pulse to Bar (Kpb) Rating__________________________________________________ 19 2T Pulse K (K2T) Rating ____________________________________________________ 20 Chrominance-Luminance Gain Inequality _______________________________________ 21 Chrominance-Luminance Delay Inequality ______________________________________ 22 Differential Gain Distortion __________________________________________________ 23 Differential Phase Distortion _________________________________________________ 24 Group Delay Response ______________________________________________________ 25 Horizontal Timing__________________________________________________________ -
Full Procedure List
PO Box 111113 Aurora, CO 80042 Phone 303.317.6670 [email protected] World’s Largest MET/CAL® Library! Cal Lab Solutions prides itself on developing the very best automated procedures in the industry. We develop solutions to address your lab’s unique requirements and are dedicated to finding the most cost- effective solution that meets your needs. One of the many services we provide includes the development of MET/CAL® procedures. We offer both off the shelf procedures matching the manufacturer’s written documentation and custom solutions based on the documentation of your choice. Below is a list of procedures ready for delivery. If you do not see what you’re looking for, please feel free to call or email for an immediate quote. MANUFACTURER MODEL DESCRIPTION Generic Caliper All Calipers Generic Micrometer All Micrometers Generic Pin Gauges All Pin Gauges Generic Torque Wrench All Torque Wrenches Generic Decade Resistor All Decade Resistors Acqiris DC265 PXI High Speed Waveform Analyzer Acqiris DC270 PXI High Speed Waveform Analyzer Acqiris DC271 PXI High Speed Waveform Analyzer Advantest R3131A Spectrum Analyzer Advantest R3261C Spectrum Analyzer Advantest R3261D Spectrum Analyzer Advantest R3265A Spectrum Analyzer Advantest R3271A Spectrum Analyzer Advantest R3361C Spectrum Analyzer Advantest R3361D Spectrum Analyzer Aeroflex 2023 Signal Generator Aeroflex 2024 Signal Generator Agilent/HP 16530A/31A Oscilloscope Module Agilent/HP 16532A Oscilloscope Module Agilent/HP 16533A Oscilloscope Module Agilent/HP 16534A Oscilloscope Module -
Verification Regulation of Steel Ruler
ITTC – Recommended 7.6-02-04 Procedures and guidelines Page 1 of 15 Effective Date Revision Calibration of Micrometers 2002 00 ITTC Quality System Manual Sample Work Instructions Work Instructions Calibration of Micrometers 7.6 Control of Inspection, Measuring and Test Equipment 7.6-02 Sample Work Instructions 7.6-02-04 Calibration of Micrometers Updated / Edited by Approved Quality Systems Group of the 28th ITTC 23rd ITTC 2002 Date: 07/2017 Date: 09/2002 ITTC – Recommended 7.6-02-04 Procedures and guidelines Page 2 of 15 Effective Date Revision Calibration of Micrometers 2002 00 Table of Contents 1. PURPOSE .............................................. 4 4.6 MEASURING FORCE ......................... 9 4.6.1 Requirements: ............................... 9 2. INTRODUCTION ................................. 4 4.6.2 Calibration Method: ..................... 9 3. SUBJECT AND CONDITION OF 4.7 WIDTH AND WIDTH DIFFERENCE CALIBRATION .................................... 4 OF LINES .............................................. 9 3.1 SUBJECT AND MAIN TOOLS OF 4.7.1 Requirements ................................ 9 CALIBRATION .................................... 4 4.7.2 Calibration Method ...................... 9 3.2 CALIBRATION CONDITIONS .......... 5 4.8 RELATIVE POSITION OF INDICATOR NEEDLE AND DIAL.. 10 4. TECHNICAL REQUIREMENTS AND CALIBRATION METHOD ................. 7 4.8.1 Requirements .............................. 10 4.8.2 Calibration Method: ................... 10 4.1 EXTERIOR ............................................ 7 4.9 DISTANCE -
Super Megohmmeter Sm-8200 Series
SM-8200 SERIES SUPER MEGOHMMETER d Tim de er, Larg splay -loa com e LCD digital/analog di fully parator ctions , remote start & communication fun 2 l Digital numeric readout with virtual analog display. Easy-to- use combined digital-analog models*1 l Timer, comparator, remote start and command functions included as standard features to support new applications*1 l Many safety-enhancing features Display Features 1– Clear, three-mode liquid crystal display*1 Bright LCD simultaneously displays data in three modes: quasi-bar-graph, virtual needle and numeric values. 2– Clear graduated scale and precise data reading*1 The one-line graduated scale is always visible, and scales automatically according to the selected measurement voltage. Data is held on the display after measuring, so there is no hurry to read it. The numeric readout displays measured values at maximum resolution. 3– Enhanced response speed and reliability*1 Reliability is enhanced because, unlike analog meters, the LCD has no moving parts, and the virtual needle responds seven times faster than a mechanical needle. Installation in automated systems is supported. Usability Features 1– Timer function included as a standard feature*1 The need for counting complicated measurement time (by stopwatch) is eliminated. Timer settings are retained in internal memory even when power is turned off. 2– Comparator functions included as a standard feature*1 Easy-to-use GO/NO-GO (Pass/Fail) decisions NO-GO (Fail) decisions can be indicated by an alarm sound simultaneously with contact output. Comparator settings are retained even when power is turned off. 3– Remote Start function included as a standard feature*1 Measurement can be started hands-free, using a footswitch or trigger signal. -
Megger Electrical Test Instruments Catalog
Megger 5/10-kV Insulation Test Equipment ................ 2 Electrical Test 1-kV Insulation Test Equipment ..................... 6 Additional Insulation Test Equipment ......... 11 Instruments Ground Resistance Test Equipment ............. 13 AC Loop Impedance Testers ......................... 17 Catalog Digital Low Resistance Ohmmeters ............. 18 Multimeters ................................................... 22 Clampmeters ................................................. 23 Time Domain Reflectometers ....................... 24 Datacom Test Equipment .............................. 26 Substation Test Equipment .......................... 27 Battery Impedance Test Equipment ............. 28 Special Maintenance Equipment ................. 30 Safety Test Equipment .................................. 34 Test and Measurement Software ................. 35 Cross Reference Guide .................................. 36 Valley Forge Corporate Center 2621 Van Buren Avenue TOLL FREE Norristown, PA 19403-2329 USA CUSTOMER SERVICE NUMBER Phone: 866-254-0962 Phone: 610-676-8500 WWW.MEGGER.COM/US Fax: 610-676-8610 1-866-254-0962 WWW.MEGGER.COM/US Contact us regarding questions, customer service and product repairs The word “Megger” is a registered trademark MEG-19961/18.5/M/2.2010 Megger 1-kV Insulation Testers… … Consist of a range of instruments for varying needs and budgets … Provide end users with more testing capability … Offer a rock solid design, making these instruments the best value proposition on the market today Look inside for information -
Hand Held Megohmmeter Model R1m-B
R1M-B Revised August, 2004 HAND HELD MEGOHMMETER MODEL R1M-B Operation and Maintenance Manual PN# R1M-B-900-01 Publication Date: July 2012 REV. C TEGAM hereby grants to the U.S. Government a limited, non-exclusive, non-transferrable license to reproduce, scan and electronically store the manuals purchased by the US Government. This license shall remain in effect for as long as the equipment cited in the manuals remains under government control and usage, after which time this license is automatically terminated. NOTE: This User’s Manual was as current as possible when this product was manufactured. However, products are constantly being updated and improved. To ensure you have the latest documentation, refer to www.tegam.com 10 TEGAM WAY • GENEVA, OHIO 44041 • 440-466-6100 • FAX 440-466-6110 • [email protected] TABLE OF CONTENTS Revised August, 2004 TABLE OF CONTENTS 1. INSTRUMENT DESCRIPTION Purpose ............................................................... 1-1 Performance Characteristics ................................... 1-1 Description of Equipment ....................................... 1-1 List of Items Furnished .......................................... 1-3 Storage and Shipping Requirements ........................ 1-3 2. PREPARATION FOR USE AND INSTALLATION Unpacking and Inspection ...................................... 2-1 Preparation for Use................................................ 2-1 3. OPERATING INSTRUCTIONS General Theory of Operation ................................... 3-1 4. PRINCIPLES OF OPERATION 5. MAINTENANCE -
Iq-Analyzer Manual
iQ-ANALYZER User Manual 6.2.4 June, 2020 Image Engineering GmbH & Co. KG . Im Gleisdreieck 5 . 50169 Kerpen . Germany T +49 2273 99 99 1-0 . F +49 2273 99 99 1-10 . www.image-engineering.de Content 1 INTRODUCTION ........................................................................................................... 5 2 INSTALLING IQ-ANALYZER ........................................................................................ 6 2.1. SYSTEM REQUIREMENTS ................................................................................... 6 2.2. SOFTWARE PROTECTION................................................................................... 6 2.3. INSTALLATION ..................................................................................................... 6 2.4. ANTIVIRUS ISSUES .............................................................................................. 7 2.5. SOFTWARE BY THIRD PARTIES.......................................................................... 8 2.6. NETWORK SITE LICENSE (FOR WINDOWS ONLY) ..............................................10 2.6.1. Overview .......................................................................................................10 2.6.2. Installation of MxNet ......................................................................................10 2.6.3. Matrix-Net .....................................................................................................11 2.6.4. iQ-Analyzer ...................................................................................................12 -
Barrel and Overall Length Measuring Procedure
TENNESSEE BUREAU OF INVESTIGATION Forensic Services Division Firearms/Toolmarks Standard Operating Procedures Manual Barrel and Overall Length Measuring Procedure 7.0 BARREL AND OVERALL LENGTH MEASURING PROCEDURE 7.1 Scope: One of the routine procedures conducted in a firearm examination is determining the barrel length and overall length of the firearm. 7.2 Precautions/Limitations: Accuracy is imperative to this examination. It is vitally important that the firearm examiner use calibrated measuring devices, or instruments checked against calibrated measuring devices. These measuring devices will be checked against a NIST traceable ruler prior to being placed into service. Also, care shall be taken if any object is placed down the barrel to help expedite the barrel length measurement. Only a non-marring item should be placed down the barrel. Test firing of the firearm should be performed prior to placing any item down the barrel if possible. TCA Section 39-17-1301 defines a short-barreled rifle and shotgun as having a barrel length of less than sixteen inches (16") for a rifle and eighteen inches (18") for a shotgun, or an overall firearm length of less than twenty-six inches (26"). TCA Section 39-17-1302 classifies those as prohibited weapons. This information is also included in the federal National Firearms Act, and may be located at www.atf.gov. 7.3 Related Information: 7.3.1 Firearm Examination and Classification Procedure 5 7.3.2 Safe Firearm Handling Procedure 4 7.3.3 Worksheet Appendix 1 7.3.4 Firearm Safety Appendix 3 7.3.5 Range of Conclusions Appendix 4 7.3.6 Measurement of Uncertainty Appendix 10 7.4. -
International Ejournals
ISSN 0976 – 1411 Available online at www.internationaleJournals.com International eJournals International eJournal of Mathematics and Engineering 211 (2013) 2075 - 2083 The Importance of Dalhousie Survey Camp for Graduate Engineering Students 1 Rajinder Singh, 2Arvind Dewangan and 3 Amarjeet Singh 1R.P.Indra Prastha Institute of Technology –RPIIT, Bastara-Karnal, Haryana INDIA. Email: [email protected] 2Civil Engineering Department, Haryana college of Technology & Management, HCTM Technical Campus Kaithal-Haryana INDIA. Email: [email protected] 3 Uraha Infra Ltd. Jodhpur-NH73 INDIA ABSTRACT: Surveying is the branch of civil engineering which deals with measurement of relative positions of an object on earth’s surface by measuring the horizontal distances, elevations, directions, and angles. Surveying is typically used to locate and measure property lines; to lay out buildings, bridges, channels, highways, sewers, and pipelines for construction; to locate stations for launching and tracking satellites; and to obtain topographic information for mapping and charting. It is generally classified into two categories: Plane surveying (for smaller areas) and Geodetic surveying (for very large areas). Surveying is the art of making suitable measurements in horizontal or vertical planes. This is one of the important subjects of civil engineering. Without taking a survey of the plot where the construction is to be carried out, the work cannot begin. Dalhousie provides all type of location in a platform . Key Words : 1.Surveying -
DC Resistance Or Conductance of Insulating Materials1
Designation: D257 – 07 An American National Standard Standard Test Methods for DC Resistance or Conductance of Insulating Materials1 This standard is issued under the fixed designation D257; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval. This standard has been approved for use by agencies of the Department of Defense. 1. Scope* Summary of Test Methods 4 Terminology 3 1.1 These test methods cover direct-current procedures for Test Specimens for Insulation, Volume, and Surface 9 the measurement of dc insulation resistance, volume resistance, Resistance or Conductance Determination and surface resistance. From such measurements and the Typical Measurement Methods Appendix geometric dimensions of specimen and electrodes, both vol- X3 ume and surface resistivity of electrical insulating materials 1.5 This standard does not purport to address all of the can be calculated, as well as the corresponding conductances safety concerns, if any, associated with its use. It is the and conductivities. responsibility of the user of this standard to establish appro- 1.2 These test methods are not suitable for use in measuring priate safety and health practices and determine the applica- the electrical resistance/conductance of moderately conductive bility of regulatory limitations prior to use. materials. Use Test Method D4496 to evaluate such materials. 1.3 This standard describes several general alternative 2. Referenced Documents methodologies for measuring resistance (or conductance). -
Moore & Wright 2016/17- Complete Catalogue
MW-2016E MW-2016E MOORE & WRIGHT Moore & Wright - Europe and North Africa Moore & Wright - Rest of the World Bowers Group Bowers Eclipse Equipment (Shanghai) Co., Ltd. Unit 3, Albany Court, 8th Building, No. 178 Chengjian Rd Albany Park, Camberley, Minhang District, Shanghai 201108 Surrey GU16 7QR, UK P.R.China Telephone: +44 (0)1276 469 866 Telephone: +86 21 6434 8600 Fax: +44 (0)1276 401 498 Fax: +86 21 6434 6488 Email: [email protected] Email: [email protected] Website: www.moore-and-wright.com Website : www.moore-and-wright.com PRODUCT CATALOGUE 16/17 Partners in Precision PRODUCT CATALOGUE 16/17 INNOVATIVE NEW PRODUCTS IN EVERY SECTION OF THIS ALL-INCLUSIVE, EASY TO USE REFERENCE MWEX2016-17_FC-BC.indd 1 19/11/2015 11:58 MOORE & WRIGHT A Brief History... Founded in 1906 by innovative young engineer, Frank Moore, Moore & Wright has been designing, manufacturing and supplying precision measuring equipment to global industry for over 100 years. With roots fixed firmly in Sheffield, England, the company began by manufacturing a range of calipers, screwdrivers, punches and other engineer’s tools. Following investment from Mrs Wright, a shrewd Sheffield businesswoman, Frank was able to expand the business and further develop his innovative designs. By the mid-nineteen twenties, thanks to the company’s enviable reputation, Moore & Wright was approached by the UK Government to consider manufacturing a range of quality micrometers. It was in this field that Moore & Wright’s status as UK agent for the Swiss Avia range of products and subsequent acquisition of the Avia brand and manufacturing rights, proved invaluable. -
LCR Measurement Primer 2Nd Edition, August 2002 Comments: [email protected]
LCLCRR MEASUREMENMEASUREMENTT PRIMEPRIMERR ISO 9001 Certified 5 Clock Tower Place, 210 East, Maynard, Massachusetts 01754 TELE: (800) 253-1230, FAX: (978) 461-4295, INTL: (978) 461-2100 http:// www.quadtech.com 2 Preface The intent of this reference primer is to explain the basic definitions and measurement of impedance parameters, also known as LCR. This primer provides a general overview of the impedance characteristics of an AC cir- cuit, mathematical equations, connection methods to the device under test and methods used by measuring instruments to precisely characterize impedance. Inductance, capacitance and resistance measuring tech- niques associated with passive component testing are presented as well. LCR Measurement Primer 2nd Edition, August 2002 Comments: [email protected] 5 Clock Tower Place, 210 East Maynard, Massachusetts 01754 Tel: (978) 461-2100 Fax: (978) 461-4295 Intl: (800) 253-1230 Web: http://www.quadtech.com This material is for informational purposes only and is subject to change without notice. QuadTech assumes no responsibility for any error or for consequential damages that may result from the misinterpretation of any procedures in this publication. 3 Contents Impedance 5 Recommended LCR Meter Features 34 Definitions 5 Test Frequency 34 Impedance Terms 6 Test Voltage 34 Phase Diagrams 7 Accuracy/Speed 34 Series and Parallel 7 Measurement Parameters 34 Connection Methods 10 Ranging 34 Averaging 34 Two-Terminal Measurements 10 Median Mode 34 Four-Terminal Measurements 10 Computer Interface 35 Three-Terminal (Guarded)