<<

Series 558 Vertical Flow Hardwall Modular Cleanrooms

CLEANROOMS

Low profile tunnel section with blowers in sidewalls. Combine multiple sections and end walls to form a cleanroom.

Series 558 Vertical Flow Hardwall Modular Cleanrooms

The Series 558 is a vertical flow hardwall cleanroom system that is designed Features to provide superior cleanroom performance. Its modular design combines  All feature full-ceiling HEPA filter functionality with flexibility to create systems that will meet your cleanroom plenum sections for superior needs of today and into the future. The full ceiling HEPA filter coverage with cleanroom performance diffuser panels and tear drop lights provide uniform airflow out of the ceiling  All metal construction plenum.  Very energy efficient  Modular sections  Easily maintained  Full HEPA ceiling coverage  High  Unidirectional airflow  Class 100 or Class 10

SOLUTIONS

 For more information or to download or fax this product from the web, simply go to: www.cleanairproducts.com/558 Series 558 Vertical Flow Hardwall Modular Cleanrooms

Overview Airflow CFM and pressure adjust- National Electric Code and all compo- The Series 558 consists of full- ments can be made as the filters load nents are UL listed. Voltage require- ceiling, HEPA filter plenum sections over time. The motor is equipped with ments will vary depending on the that provide filtered laminar flow air to a variable pitch pulley to control the number of lights used. clean areas. These sections are designed speed of the blower. This allows for to deliver filtered air through 100% of adjusting the blower CFM and pressure Vibration the ceiling’s available surface area. to the system as the filters load over The blower/motor is vibration The Series 558 is constructed from time. isolated from the cleanroom utilizing heavy-duty 16 gage cold-rolled steel the VIBO-STAT isolation system. with a white baked-enamel or powder Filters coat finish. Filters are rated 99.99% efficient on Environmental Control The Series 558 uses side wall 0.3 micron and larger particles An optional temperature and blower cabinets that blow air into utilizing a DOP smoke test. The frame control can utilize the house upper filter plenums. The side wall is extruded aluminum. airconditioning system or can be

CLEANROOMS cabinets contain start/disconnect, wall Filters are changed from the supplied by Clean Air Products with receptacles, prefilters and optional underside of the filter unit. the cleanroom in one of the following cooling coils. Units can be designed Other filter options are available methods: DX (direct expansion), Freon so these items are serviced from upon request. system, or inside or outside the cleanroom. coils. The chilled water coils utilize Multiple sections combine together Prefilters 45°F inlet customer provided water or along with end wall to form a The prefilters are a disposable a water can be provided. cleanroom. pleated style of standard industrial size. They use a non-woven cotton Filter Section Sizing Motor/Blower fabric reinforced with a wire mesh The following sizes are for the filter The motors are efficient 3-phase, backing. The prefilters have a rigid section only and do not include the 1,725 RPM open drip-proof. They Kraftboard frame. They have a 40% blower/motor or optional cooling coil have pre-lubricated ball bearings, 1.15 efficiency rating. sections. service factor and are recognized by NOTE: 4, 5 and 6 ft. widths. Two UL for their construction. The voltage Lighting units can be joined together using can be 208, 230 or 460 volts, 60 Hz The lighting is tear drop fluorescent, spanning brackets to form spans up to which is standard; other voltages and and individual lights can be spaced 32 ft. Longer spans available upon 50 Hz are available. The specific evenly below the HEPA filter or request. operating voltage must be specified. positioned between them. The NOTE: Motor HP will vary depend- lighting has a minimum of 90 Options ing on ceiling filter plenum size. footcandles illumination. The lights • Fire sprinklers – water or Halogen The blowers are belt-driven by the have a light diffuser grill to provide as well as smoke, heat infrared fire motor at a fixed speed (1,725 RPM). glare-free lighting and provide detection equipment can be A variable pitched pulley is installed protection for the HEPA filter. provided to meet your require- on the motor. CFM and greater air Greater lighting levels are available ments velocities are achieved by moving the upon request. • Hardwall – can be provided to belt to another pulley on the motor. meet your requirements. Support An optional direct drive motor is Sound Attenuation (Optional) legs can be made to meet any available upon request. Parts of the units are lined with internal height requirements. acoustical liner to assist in sound The walls can be insulated or Airflow attenuation. non-insulated and can be fur- The airflow is 90 LFPM+/-20 LFPM nished in a variety of materials. average uniformly at the filter face as Electrical — Aluminum defined by Federal Standard 209E. The wiring conforms with the — Painted Aluminum

2 Solutions Built to tel: 763.425.9122 800.423.9728 Your Specifications. www.cleanairproducts.com Series 558 Vertical Flow Hardwall Modular Cleanrooms

CLEANROOMS

— Painted Steel • ULPA filter 99.999% on 0.12 — Vinyl Covered Steel micron particles — Other materials available upon • 230V, 460V, 50 Hz and other request voltages • Temperature control — can be • Solid-state speed control provided from comfort cooling to precise temperature ± 0.5°F and Guarantee humidity control to ± 2% RH. A written 1 year warranty is Chilled water or DX coils can be furnished with each cleanroom. built into the filter modules, saving the cost and valuable space taken up by a ducted air cooling system. • Humidity control – humidity control can control both the minimum and/or maximum depending on the systems used. Control types 1) supply upper control, no humidity will be added, 2) upper and lower control with humidity being added by an electric steam . The control limit of ± 5% RH is typical but can be controlled to ± 2% RH. Consult the factory on particular applications. • Extra sound attenuation – extra sound attenuation can be built into the Series 558 units in which the blowers blow into a supply duct prior to going into the air plenum. • A/C inlet collar – would allow for an outside airconditioning system to be connected to the cleanroom for cooling and other environmen- tal control. • Starters and disconnects – can be provided mounted on the units or can be assembled on a pre-wired control panel. The pre-wired control panels would have main disconnects, step down control transformers, starters, indicating lights, start/stop controls, etc., all pre-wired and tested. This system would eliminate much of the on- site wiring. • Emergency shut down and com- puter controlled off-hours controls Specifications subject to change. Please contact factory for details.

Solutions Built to Your Specifications. 8605 Wyoming Ave. N. • Minneapolis MN 55445 tel: 763.425.9122 800.423.9728 fax: 763.425.2004 e-mail: [email protected] www.cleanairproducts.com

© Clean Air Products 2004 PM0558-1B 8.24.04