Sewerage Manual Part 1) Should Be Adopted
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Packaged Pump Stations Xylem’S Market Leading Products Will Save You Time and Money
Flygt N-technology parts and upgrade kits CLOG-FREE PUMPING. MINIMIZED ENERGY COSTS. • Self-cleaning impeller • Cutting groove provides seal protection • Well-balanced and modular design • High energy efficiency • Resistant materials • Adaptive N-hydraulics • Upgrade kits • Tight tolerances Packaged Pump Stations Xylem’s market leading products will save you time and money Service centres Australia New Zealand Adelaide: Karratha: Leewood: Auckland (head office): 22 Starr Avenue, Lot 4605 Croydon Road, 48 Leewood Drive, Orange 9 Tawa Drive, Albany, North Plympton, SA 5037 Karratha Industrial Estate, NSW 2800 Auckland 0632 Ph +61 8 8350 7100 Karratha WA 6714 Ph +61 2 9832 6730 Ph +64 9 415 8687 Fax +61 8 8350 7111 Ph +61 8 9183 8246 Fax +61 2 9832 6731 Fax +64 9 415 8679 Fax +61 8 9183 8248 Brisbane: Perth: Christchurch: Unit 1/39-45 Aquarium Ave Mackay: 76 Tarlton Crescent, Unit 6, 4 O’Briens Rd, Hemmant QLD 4174 7 Merchant Street, Paget, Perth Airport, WA 6105 Sockburn, Christchurch 8042 PO Box 2331 Mackay QLD 4740 Ph +61 8 9475 1900 Ph +64 3 348 4612 Mansfield QLD 4122 Ph +61 7 4842 9200 Fax +61 8 9475 1999 Fax +64 3 348 4629 Ph +61 7 3908 4000 Fax +61 7 4842 9299 Fax +61 7 3908 4199 Sydney (head office): Wellington: Melbourne: Unit 2, 2 Capicure Drive, c/9 Tawa Drive, Albany North Darwin: Unit 3, 1 Federation Way, Eastern Creek NSW 2766 Harbour, Auckland 29 McCourt Road, Chifley Business Park, Ph +61 2 9832 6200 Ph +64 021 746 441 Yarrawonga, NT 0830 Mentone VIC 3194 Fax +61 2 9832 6480 Fax +64 802 4432 Ph +61 8 8947 8300 Ph +61 3 8551 -
Sewer Overflow Response Plan
DAPHNE UTILITIES SANITARY SEWER OVERFLOW RESPONSE PLAN RECORD OF PLAN REVISIONS REVISION SECTIONS INITIALS REMARKS DATE REVISED 12/15/18 All Draft Plan Created 03/15/19 All Original Plan Published Table of Contents I. Purpose ..................................................................................................................................... 1 II. General ....................................................................................................................................... 1 III. Objectives .................................................................................................................................. 1 IV. System Information .................................................................................................................... 1 V. SSO and Surface Water Assessment .......................................................................................... 2 VI. Sanitary Sewer Overflow Response Procedures ........................................................................ 2 A. Notification of Possible SSO ........................................................................................ 3 B. Dispatch of Appropriate Crews to Site of Sewer Overflow.......................................... 3 C. Overflow Correction, Containment, and Clean Up ...................................................... 4 1. Responsibilities of Response Crew upon Arrival............................................... 4 2. Initial Measures for Containment...................................................................... -
Private Sewer Systems Defects and Overflows How Do Sewer System
Private Sewer Systems Defects and Overflows Most sanitary sewer systems are constructed as a network of manholes and pipes that flow from each building that generates sewage to a wastewater treatment plant. Private services, also called laterals, are pipes from the building to the sewer main. In some areas, the public system owns and maintains the “lower lateral” from the sewer main to the edge of the easement or right-of-way, and the private property owner owns and maintains the “upper lateral” the remainder of the way to the building. In other areas, the private property owner owns and maintains both the lower and upper laterals. Finding and fixing sewer defects on private property sewer systems can prevent sewer overflows and backups that can cause health hazards, inhibit economic growth, and result in long-term environmental damage. How Do Sewer System Defects Cause Overflows? Private sanitary sewer systems, the earliest of which were built in the mid 1800s, carry domestic wastewater away from private properties separately from stormwater. These systems have deteriorated over the years, are typically not maintained or replaced due to funding, and their ability to transport sanitary wastewater has been compromised due to population growth. As a result, these systems can experience separate sanitary sewer overflows (SSOs) both on public and private property. SSOs are generally caused by infiltration that occurs when clean water such as groundwater enters the sanitary sewer through defects in the system or inflow from stormwater that enters the system through defects and illegal connections. SSOs can also be caused by inadequate pipe sizes when population growth exceeds the original design conditions. -
Actions for Flood Resilient Homes: Sewage Ejector Pump
Actions for Flood Resilient Homes: Sewage Ejector Pump What is a sewage ejector pump? Who needs a Sewage Ejector Pump? A sewage ejector pump is used when plumbing fixtures You’ll need an ejector pump if you have plumbing fixtures at a in your home are located below the main sewer line (e.g., lower level than the municipal sewer line. basement bathrooms or laundry rooms). It is designed to A permit is/is not required elevate wastewater so it can move up and out of your home to the sewer. Before flood action During flood action After flood action How does a sewage ejector pump Other considerations work? • A standard ejector pump kit with a ½- to ¾-horsepower A sewage ejector pump is required when a motor and a 30- or 40-gallon tank is normally big enough for an home’s wastewater discharge pipe is elevated average residential installation. above plumbing fixtures. The advantage • You may opt to install a backup pump to guard against failure. of having an elevated discharge pipe is that You can also consider buying a pump that sounds an alarm sewage in the city sanitary pipes is less likely to when the pump fails. flow into the home by gravity. This approach is similar to the use of a backflow prevention • Ejector pumps generally last several years if well maintained. valve. You should schedule a plumber for annual service (cleaning the pump, oiling the motor, inspecting the float and condition of the Like a sump pump, an ejector pump sits in pump, removing debris lodged in the tank). -
Construction of Submersible Sewage Pumping Stations
STS402 Hunter Water Corporation A.B.N. 46 228 513 446 Standard Technical Specification for: CONSTRUCTION OF SUBMERSIBLE SEWAGE PUMPING STATIONS This Standard Technical Specification was developed by Hunter Water to be used for the construction and/or maintenance of water and/or sewerage works that are, or are to become, the property of Hunter Water. It is intended that this Standard Technical Specification be used in conjunction with various other standard and project specific drawings and design requirements as defined by Hunter Water for each particular project. Hunter Water does not consider this Standard Technical Specification suitable for use for any other purpose or in any other manner. Use of this Standard Technical Specification for any other purpose or in any other manner is wholly at the user's risk. Hunter Water makes no representations or warranty that this Standard Technical Specification has been prepared with reasonable care and does not assume a duty of care to any person using this document for any purpose other than stated. In the case of this document having been downloaded from Hunter Water's website; - Hunter Water has no responsibility to inform you of any matter relating to the accuracy of this Standard Technical Specification which is known to Hunter Water at the time of downloading or subsequently comes to the attention of Hunter Water. - This document is current at the date of downloading. Hunter Water may update this document at any time. Copyright in this document belongs to Hunter Water Corporation. Hunter Water Corporation A.B.N. 46 228 513 446 CONTENTS 1. -
Solving Sewer Overflows: Foundation Drains: in Some Homes, Sump Pumps Were Installed to Discharge Water Is Essential, but Can Cause Problems Solutions
COMMON HOME DRAINAGE Inflow and infiltration is a problem that How do I get started? affects everyone in area communities. Clean Read this brochure to learn more about I & I and possible Solving Sewer Overflows: Foundation Drains: In some homes, sump pumps were installed to discharge water is essential, but can cause problems solutions. Then, contact your municipal wastewater utility. water directly into a drain pipe or the basement sink. Many homes have special drain pipes installed around They will be able to direct you to local programs and This method still allows clear rainwater to enter the if misdirected around homes and sewers. the base of the foundation to catch and drain water information about I&I in your community. A Simple Guide for Homeowners sanitary sewer. To redirect your sump pump, a new that runs down the outside of the house. These rigid outlet pipe should be installed to exit through the Determine if your home is part of the Cloquet . (218) 879-6758 foundation drains direct water into the sump pit in exterior wall of your basement. This pipe should carry problem. You can stop inflow and infiltration the basement, where it should be pumped out by a Scanlon . (218) 879-4578 water at least four feet away from the foundation sump pump into the yard. Clear rainwater runoff from your home through some quick and easy Duluth . (218) 730-4130 through an above or below ground extension. from foundation drains should never be allowed to solutions. Properly installed gutters and a Hermantown . (218) 729-3625 drain into the sanitary sewer. -
Sanitary Sewer & Pumping Station Manual
SANITARY SEWER AND PUMPING STATION MANUAL FOR SPRINGFIELD WATER AND SEWER COMMISSION Last Revised: _July 20, 2017______________ Page 1 TABLE OF CONTENTS Title Section Number General 1 Drawing Requirements 2 Construction Procedures 3 Flow Determination 4 Computer Modeling 5 Sanitary Sewers 6 Pump Stations 7 Appendices A – Checklist B – Construction Specifications C – Standard Drawings Page 2 SECTION 1 – GENERAL 1.1 General................................................................ 4 1.2 Purpose................................................................ 4 1.3 Structure of the Manual................................................ 4 1.4 Definitions............................................................ 4 1.5 References............................................................. 9 Page 3 1.1 General The Sanitary Sewer and Pumping Station Manual is for the design and construction of infrastructure. The specific subjects of these manuals are: • Procedures Manual for Infrastructure Development • Sanitary Sewer and Pumping Station • Structures • Geotechnical • Construction Inspection 1.2 Purpose The purpose of this manual is to provide information regarding design and construction requirements for sanitary sewers, pumping stations, and force mains in Springfield, Kentucky. The goal is to provide uniform design and construction standards. The end result will be public infrastructure that is cost effective and maintainable by the Springfield Water and Sewer Commission (SWSC)in the long term. 1.3 Structure of the Manual The manual -
Sump Pump Information Card
Sump Pumps into the Sanitary Sewer Create Health and Safety Risk! Aside from the fact that connecting sump pumps to the sanitary sewer is illegal, it can cause significant health and safety risks. Sump pumps are designed to pump groundwater and rain water. Generally, the sanitary sewer pipe in the street is only 8 inches in diameter, and often the pipe slope is not very steep. Many 8 inch sewer pipes are installed with a slope of 0.4%. This means that for every 100 feet of pipe, the pipe goes downhill less than 5 inches. This low slope condition is very common in Washington County sewer collection systems, which means there is only so much sewage water that can flow through this pipe. For this type of sewer pipe, about 300 gallons of water can flow through it in a minute. If more sewage than this tries to get through the pipe in the street, the sewage will surcharge, that is start filling up the sewer lateral pipes that run to the sewer main from houses. When even more sewage or extra water is sent to the sewer pipe, it will surcharge even farther, eventually pushing back into someone’s basement. The sewage might come out of a neighbor’s basement toilet or washing machine drain for example. If hooked up to a house’s sewer lateral, a half-horsepower sump pump will pump about 60 gallons to the sewer each minute. That means that if 5 pumps are connected to the sewer, it will be full. Normal sewage flows often fill the sewer main more than half-way already. -
Homeowner's Guide to Drainage Problems and Solutions
< O •OOOOOOOO•••••••••••OO O OO OO•OO O• ooooOo o•o •O••••• ••OOOOOOOOOOOOO ••OloOI oo0000000000 004•00•0•00•••• •••o 000 00 0 0 00 ..00000000000•0 0U • 00 0 ..000000 •• •• oooo00o ..OOOO OOO•••oo ....000•000 ..0 00 • 0000 ..000000• 0 00 0•00000 ..000000o•OU•o oo ..OOOO OOO A H O M E O W N E R ' S G U I D E T O D R A I N A G E P R O B L E M S A N D S O L U T I O N S Prince George’s County Department of the Environment Residential Drainage A HOMEOW NER' S GUIDE TO DRAINAGE PROBLEMS AND SOLUTIONS Contents 1. Introduction ............................................................................................. 1 2. Basement Flooding Problems .......................................................... 1 2.1 Basement Construction ........................................................ 1 2.2 Primary Causes of Basement Flooding ....................................... 2 2.2.1 Break in Waterline Connection or House Plumbing ............... 2 2.2.2 Direct Inflow of Surface Water .................................. 2 2.2.3 Surface Water Infiltration .......................................... 3 2 .2.Li Groundwater Infiltration ......................................................... 5 2 .2.5 Areaway Drain Surcharge or Blockage .................................. 5 2.3 Determining the Best Course of Action ........................... 6 3. Basement Waterproofing & Drainage Systems ............................. 6 3.1 Reparging Exterior Walls ..................................................... 6 3.2 Exterior Barriers & Soil Treatments ................................... -
Analysis of Concrete Corrosion of Manhole Located Near Source of Odorous Emission
ARCHITECTURE CIVIL ENGINEERING E NVIRONMENT The Silesian University of Technology No. 4/2018 doi : 10.21307/ACEE-2018-057 ANALYSIS OF CONCRETE CORROSION OF MANHOLE LOCATED NEAR SOURCE OF ODOROUS EMISSION Bożena GIL a, Barbara SŁOMKA-SŁUPIK b*, Katarzyna KOWALSKA c, Karol JASIŃSKI d a PhD; Faculty of Environmental Engineering and Energy, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland b PhD; Faculty of Civil Engineering, Silesian University of Technology, Akademicka 5, 44-100 Gliwice, Poland *E-mail address: [email protected] c PhD; Faculty of Environmental Engineering and Energy, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland d MSc; Faculty of Environmental Engineering and Energy, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland Received: 13.02.2018; Revised: 27.04.2018; Accepted: 22.05.2018 Abstract The problem of corrosion of sanitary sewer concrete concerns the elements located just behind the expansion well. Evolving odorogenic substances and bioaerosols spread in the sewage system, cause in adverse conditions both chemical and biolog - ical corrosion of concrete. The paper presents the results of tests of samples taken from the top concrete circle and from a corroded cast iron hatch of 7 years old manhole located below the expansion well. Well elements were subjected to a strong interaction of hydrogen sulphide, which average concentration in the sewage air, during an exemplary 84 hours was 29 ppm. Concrete was gelatinous fine with noticeable outer pellicular layer of 1 mm thick and the inner layer containing aggregates (grain < 1 cm). Sulfur oxidizing, sulfates reducing, Fe 2+ oxidizing bacteria, aerobic heterotrophs, anaerobic heterotrophs, nitrifiers and denitrifiers were determined. -
Reducing Inflow and Infiltration Part 1: Sump Pumps
REDUCING INFLOW AND INFILTRATION PART 1: SUMP PUMPS In this series of articles I will discuss cost effective ways of reducing inflow and infiltration to our wastewater facilities. Inflow and infiltration are defined below. INFLOW: “THE WATER DISCHARGED INTO A SEWER SYSTEM AND SERVICE CONNECTIONS FROM SUCH SOURCES AS ROOF DRAINS, SUMP PUMPS, FOUNDATION DRAINS, COOLING WATER DISCHARGES, MANHOLE COVERS, COMBINED SEWER SYSTEMS, CATCH BASINS, STORM WATER AND SURFACE RUNOFF” INFILTRATION: “THE WATER ENTERING SEWER PIPES AND SERVICE CONNECTIONS FROM THE GROUND. DEFECTIVE PIPES, JOINTS, CONNECTIONS AND MANHOLE WALLS ARE COMMON LOCATIONS OF INFILTRATION” Sump pumps are used by some home owners to remove unwanted water from basements. Unfortunately, a lot of these sump pumps are hooked into home owner sewer lines. This is a direct connection to the sewer collection system and results in extra influent flow, that the collection system has to handle and the wastewater facility has to treat. This treatment of unwanted ground/surface water wastes valuable facility capacity and restricts the amount of future hookups and growth of a community. A huge waste of money and time will result in wastewater facility upgrades due to lack of capacity that has been taken up by inflow and infiltration sources. Sump pump discharges can also cause wwtfs to use extra electricity, chemicals and can affect the efficiency of the treatment process. A typical homeowner sump pump (40 gallons/minute) running 10 minutes per hour can pump 9,600 gallons per day. If there are 20 similar sump pumps in your community, 192,000 gallons of unwanted water is being sent to your wastewater facility in one day! There are several ways to ensure that sump pumps are not tied into sewer collection systems: -Education, Many home owners do not realize the problems they are causing by hooking sump pumps into their sewer lines. -
Global Wastewater Challenges - Pt
GLOBAL WASTEWATER CHALLENGES - PT. 3 Global Wastewater Challenges Place wastewater treatment station, which means only pre- Pressure on Aging Infrastructure screened sewage has to be pumped? Pumps & Systems January 2016 Part 3 of 6 Shifting trends in water use and a changing sewage composition cause complex problems for the world’s sewer systems. Figures 1 (left) and 2 (right). Two general designs of By Horst Sturm (KSB) a submersible pumping station (Images and graphics courtesy of KSB) Third of Six Parts The content and mix of the pumped fluid matters greatly. Often, “sewage” is the only information When a system is not working as expected, users and application engineers receive when asked to specify engineers must see the complete picture, especially in pumps. But providing a detailed definition of the wastewater transport systems. While the increasing particular fluid (i.e. unscreened raw sewage, pre- use of wipes is a challenge, as discussed in Parts 1 screened sewage, stormwater, sludge) is vital for and 2 of this series (Pumps & Systems, November selecting the hydraulic/impeller. Especially in raw and December 2015), different systems will handle sewage, increased wipe use compounds the challenge this problem differently, and different fluid content for pump selection, system engineering and operation. will influence performance. Wastewater is not all the same. Depending on the operation or the system’s This article will exclude pre-screened wastewater and design, the sensitivity can vary for the particular kind focus on the transport of raw sewage to treatment of wastewater. plants. Several international initiatives attempt to clarify and Pump Station Designs define different wastewater.