Hydronic HVAC Made Real with Radiant

Total Page:16

File Type:pdf, Size:1020Kb

Hydronic HVAC Made Real with Radiant Radiant by Joe Fiedrich RADIANT AUTHORITY Hydronic HVAC Made Real with Radiant his is a 2017 test site installa- For what I’m calling in this article enough sq footage of panel output is as this one. It keeps the overall sys- tion performed in a wood frame a “hydronic HVAC system,” the best available, an additional fan coil unit is tem cost in check, while performing Thouse (including garage, work- place to locate the tubing panels is an option.) both functions. shop and upstairs apartment) located There are any number of consider- in Carlisle, MA. The system has been in ations to keep in mind in a combina- operation for the past two winters and the best place to locate the tubing tion heating/cooling hydronic system summers under New England weather such as this one. conditions (which, for those who don’t panels is typically the walls and ceilings. A small buffer storage tank is defi- know, are hot and humid in the warm nitely recommended for overall months, cold and snowy in the cool typically the walls and ceilings. For a As a rule of thumb, try to cover the smooth system operation. ones). typical installation, the entire ceiling entire ceiling with panels to deliver Additional super quiet flat panel heating/cooling units can be added where needed for additional output and fast recovery on both heating and cooling functions. If a domestic hot water system needs to be integrated, the buffer tank needs more storage capacity with tank sizes of 37 or 70 gal. and a built-in heat exchanger (in this case a Chiltrix VCT or HCT Series) for pota- ble water. Otherwise a separate water heater is recommended, which will Chiltrix dew point controller. simplify the whole system design. In case the buffer tank is supplying DHW, a mixing valve needs to be installed between the buffer tank and the HVAC manifolds. A functional tub- Radiant Heating and Cooling R+D Building, Carlisle Ma. ing grid system is essential for equal heating and cooling water distribution in the ceiling and or Chiltrix fan coil unit for heating, cooling and dehumidification walls. Panels must be the proper square footage of radiation; easy to install over joists and studs and this is the key for system efficiency in existing sheet rock as well as concrete conjunction with heat pumps. The and concrete blocks to receive small more radiant surface the better, since it diameter tubing. will guarantee the lowest heating water Tubing spacing should not exceed temps as well as the highest chilled wa- 4.5", and circuit length not to exceed ter temps possible. 150 feet for 5/16" diameter ID tubing. After tubing insertion and before Small diameter oxygen Barrier PEX sheet rock or plaster board installa- tubing with small tubing spacing tion, aluminum foil was attached to and short circuits is essential and re- the grid panels via spray adhesive. duces both the dew point and con- Chiltrix air-to-water heat pump chiller.t This promotes the cooling radiant densation. The first step was to perform a com- should be covered with tubing pan- effect downwards. Conducting heat- Tubing must tidally snap into panel putation of the heating and cooling els and, if necessary some additional ing radiation downwards is a good grooves for secure mounting. load for the space. This particular home wall spaces. BTU output per panel (10 alternative to floors as well, which To keep material cost down, man- had all-fiberglass insulation, with walls sq. ft.) at a water temperature of 100°F makes the ceiling the best location ifold balancing valves can be elimi- and ceiling R19, roof R32. is approximately 120 BTU/hr. (If not for a combination panel system such ➤ Turn to Hydronic, page 38 32 • SEPTEMBER 2020 ➤ www.contractormag.com Best Practices Hydronic HVAC Made Real with Radiant ➤ Continued from page 32 nated by piping the manifold supply and return in “reverse return” fashion back to the circulator. However purg- ing system air during the initial fill be- comes a little more challenging. The supply and return between the Heat Pump Chiller can also be piped with PEX Barrier tubing. Copper or alu- minum PEX rigid pipe is an option. To prevent surface condensation, ad- ditional measures must be taken in geo- graphical areas of high humidity con- ditions, with RH of 60% and higher. In this application the heat pump chiller was equipped with an additional dew point controller to ramp up the water temperature during high humidity lev- els. In addition, we installed a Honey- well dehumidifier to keep the air at RH of 50% or lower. However, the CXI fan coil units we used can also be used as dehumidifiers. We never observed any ceiling sur- Upstairs plastered Blueboard Heating/Cooling Ceiling. (Inset) Radiant ceiling grid by Hydronics Mfg. Thermal images of the radiant cooled Get your own face condensation or wet equipment ceiling. (such as metal tubing, circulators or manifolds) even the extreme. Surface temps of the plasterboard was under outside conditions of 90% RH. 65°F, maintaining 72°F room temperature. In reverse Humidistat # H6062 A 1000 subscription today Under extreme outdoor temperatures of below for the heating mode we never observed water tem- • Circulators: Grundfos UPS 15-58FC3-speed per minus 20°F our supply water temperature never ex- peratures above 90°F. manifold ceeded 90°F. And at plus 95°F outdoor temperature These low water temperatures are essential for the • Distribution Manifolds: 1” Stainless Steel Plumbing, piping, mechanical, hydronic heating and fire Chilled water temp. of 48°F with a return of 57°F was heat pump’s efficiency, especially at outdoor condi- • Zone control: circulators controlled by Honey- tions under 32°F. A small, wall hung, electric boiler well thermostats. sprinkler contractors turn to Contractor Magazine for how-to can be piped in series with the heat pump. • Tubing suppliers: Uponor and Viega. HydroData Multimeter® Necessarily high and low operating water tempera- • Tubing distribution system: 5/16” PEX Tub- features, insight, industry exclusive reports and the latest tures are possible due to the large unobstructed ceil- ing with Oxygen Barrier 0-250 PSI Gage & Differential Pressures ing surface areas providing us with an ideal square • Tubing mounting grid system: Hydronics news, products, and technologies. Associated High Side & Low Side Pressures -67 to 260 °F Temperature foot area which allow water temps. almost approach- Mfg. UNI-Panels for Ceilings and Walls, ½”X32”X48” ing room temperature set points. with tubing spacing of 4.5” on center and snap in 100 Reading Memory with Sequential Recall grooves for secure tubing mounting. English & Metric, Auto-Read The typical Delta T between heating supply and Contractor’s mission is to help plumbing, hydronic and mechanical return is 10°F, and chilled water temp. return and • Antifreeze solution: 10-20% of heating sys- supply 10°F under design conditions. tem-rated polypropylene glycol. contracting business owners and managers run better businesses and help Zone control can easily be achieved by either circu- • Heating/Cooling transfer sheeting: 6 mil lator or manifold zone valves. aluminum foil them maintain, repair and install plumbing, heating, specialty piping and For additional information please check www.Hy- Equipment List dronicsmfg.com. For more info please email jfiedrich@ fire protection systems for residential and commercial, industrial and • Heating/cooling source: Chiltrix Air to Water hydronicsMFG.com. Hydronics Manufacturing is a Heat Pump Chiller CX34 : 3 Tons heating and 2 Tons supplier of the Uponor QuikTrak panel and the Viega institutional buildings throughout North America. Cooling Climate Panel system. Chiltrix (www.Chiltrix.com) • Control system: Chiltrix Psychrologix (check was the supplier of the heat pump chiller equipment out www.chiltrix.com for control sequence), Honey- for this project. well Humidistat and Thermostats SIGN UP TODAY AT: AvailableAvailable inin PrintPrint & DigitalDigital FormatsFormats • (Optional) High efficiency chiller fan coil Joe Fiedrich is a former hydronic heating columnist for Shortridge Instruments, Inc. units: CXI 120, 12,000 BTU cooling and 10,000 CONTRACTOR. He was the president of Stadler Corp., BTU heating which is now part of Viega North America, and he is the ContractorMag.com/NewSub 7855 E. Redfeld Road Scottsdale, AZ 85260 • Buffer Tank: 19 Gallon Stainless Steel by Chil- inventor of the Viega Climate Panel and Uponor Quik 480-991-6744 Fax: 480-443-1267 trix Trak. He is now President/CEO of Hydronics Manufac- www.shortridge.com • De-humidifier: Honeywell model # DR 65 with turing Inc. For information circle 218 38 • SEPTEMBER 2020 ➤ www.contractormag.com Available in print and digital formats. 2006CO_Shortridge_337577-0620.indd 1 5/6/20 12:34 PM 2007CO_House_NewSub.indd 1 6/11/20 9:41 AM.
Recommended publications
  • 5 Products the Hydronics Industry Needs
    hydronics workshop JOHN SIEGENTHALER 5 products the hydronics industry needs that could move the industry closer to the goal of creat- These products would ing superior comfort where and when it’s needed, using the least amount of energy possible. help fill needs within This month, I’ll ask for your indulgence as I describe five of my “wish list” product ideas. I’ll do my best to the hydronics market. justify why I think these products are needed. A PLUG-AND-PLAY CONTROLLER FOR RADIANT COOLING ll companies that supply hydronic heating There are many indications that electrically driv- hardware to the North American market strive en heat pumps will claim an increasing share of the A to offer products that are currently in demand. future hydronic-heat-source market. Society’s increasing Some even look farther down the road, anticipating ambivalence toward fossil fuels, government policies and where the market is headed. They develop strategies for incentives that encourage low-carbon renewables, and products that may be ahead of their time, yet eventually utility scale electricity from wind farms and large photo- stand ready to fill a future market niche. voltaic installations all help shape this trend. Most of us who have worked in the hydronics indus- Geothermal water-to-water heat pumps and air- try have ideas for new or improved products that could to-water heat pumps will both see increasing use as make our job easier, faster or more profitable — ideas hydronic heat sources. The icing on the cake is that both FIGURE 1 outdoor temperature
    [Show full text]
  • Building Automation Systems E Solutions Provides Building Automation to Our Clients Utilizing the Following Control Lines
    521 Lovell Road, Suite 206 • Knoxville, TN 37932 • Tel:(865) 270-6111 • www.ESolutionsTN.com • Email:[email protected] Cambridge Engineering Kelvion www.cambridge-eng.com www.kelvion.com Direct fired heaters for Space Heating, Make-Up Air Complete line of plate, shell and tube, air cooled and Infrared Radiant Heating and finned tube heat exchangers Mitsubishi Electric Camus www.mehvac.com www.camus-hydronics.com Mitsubishi Electric Cooling & Heating provides a Commercial & industrial, condensing and non- complete line of variable refrigerant flow zoning condensing hot water boilers & hydronic water systems (City Multi) and mini-splits (Mr. Slim) heaters Reznor Carel USA www.reznoronline.com www.carelusa.com 100% OA units, gas fired make-up air equipment, Manufacturer of humidifiers and controllers for unit heaters, electric heaters and duct furnaces HVAC/R applications Steril-Aire Carrier www.steril-aire.com www.commercial.carrier.com Global leader in UVC solutions for improved IAQ Full line of applied products including water and air and long term system efficiency cooled chillers, air handlers, large rooftop and split systems, fan coils, self-contained units and controls Stulz www.stulz-ats.com Precision air conditioning for Computer Rooms CONSERV and Data Centers including in-row cooling and www.conserv.com ultrasonic humidifiers Fixed Plate Energy Recovery Ventilators (ERVs) with sensible and latent heat transfer Swegon www.swegon.com Desert-Aire Chilled Beam products as well as DOAS units www.desert-aire.com Refrigeration-based
    [Show full text]
  • Loft Complex Saves by Optimizing Hydronics
    ASHRAE TECHNOLOGY AWARD CASE STUDIES 2019 Loft Complex Saves By Optimizing Hydronics Montreal’s renovated De Gaspe Complex fits the artistic vibe of its neighborhood, housing mainly multimedia clients whose work requires a demanding cooling load. PHOTO SMITH VIGEANT ARCHITECTES; DANIEL ROBERT, P.ENG., MEMBER ASHRAE; STANLEY KATZ, MEMBER ASHRAE; SIMON KATTOURA, P.ENG. PHOTOS BY ADRIEN WILLIAMS ©ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE’s 48permission.ASHRAE For more JOURNAL information aboutashrae.org ASHRAE, visitAPRIL www.ashrae.org. 2019 SECOND PLACE | 2019 ASHRAE TECHNOLOGY AWARD CASE STUDIES The De Gaspe Complex (5445/5455 de Gaspe) is located in the heart of the Mile End neighborhood in Montreal, Canada, which has been known for its artistic district since the 1980s. Today, the Mile End is internationally recognized as a breeding ground for multimedia, for companies centered on artistic and creative technol- ogy. A renovation of the two-building complex resulted in a 22% reduction in energy consumption despite the demanding cooling profile of most of the new multime- dia tenants and nearly doubling the occupancy. Built in 1972 to be used as indus- Before the HVAC infrastructure trial condos for the clothing upgrade, the building was mainly manufacturing industry, De Gaspe heated by high-temperature water Complex was converted to loft type radiators located around the perim- office spaces between 2014 and eter of the building and fed by three 2016. The complex has a gross area old hot water boilers installed in the of 1,124,913 ft2 (104 508 m²) spread mechanical penthouse on the top over 11 floors in 5445 de Gaspe and floor of each building.
    [Show full text]
  • Solar Hot Water & Hydronics
    Solar Hot Water & Hydronics Sizing and Selection Guide List Prices 2009 Contractors • Wholesalers STS Solar Storage Plus System Boiler More Solar, Less Gas Solar Recirc Supply Recirculate Excess Hot Water Solar Heat To Gas Fired Tank To Heating Supply Hydronic Heating Air Handler Electric Radiant Element Solar Convector Hot Hot Water 92% Efficient Heating Return Electric Water Capacities Element Hot Water Coil Electric 92% AFUE Element 130,000 BTU Munchkin 199,000 BTU Solar Pump Boiler Potable Module Potable Solar 80 gallon Expansion Expansion Hot Water Tank Tank Recirculation 119 gallon 10K 10K 10K Sensor Sensor Expansion 10K Sensor Solar Pump Tank Sensor Solar Pump Module Taco Module Solar Coil 003 Solar Coil P1 Cold IFC Solar Coil P1 Potable P2 Expansion Tank Solar Heat Exchanger Drain Cold Cold Connects Circulator to Control Circulator & Check Valve Solar Tank Closed Loop Conventional Gas Water Heater www.stssolar.com Solar Thermal Systems • 4723 Tidewater Avenue • Oakland, CA 94601 • t 800-493-8432 • f 510-434-3142 • www.stssolar.com Solar Booklet_0409 Introduction Solar Thermal Systems About STS STS is a California and Nevada primary packager of certified solar hot water systems, solar collectors, tanks and other solar products serving the wholesale, contracting and specification, community. Our products are represented exclusively by Manufacturers Representative JTG/Muir. For technical information, literature and a list of distributors please call 800- 493-8432 and visit our web site at www.stssolar.com. Experience Our company has a combined 55 years of solar thermal experience. We are committed to providing quality systems and components with excel- lent performance designed to operate reliably and durably.
    [Show full text]
  • Idronics 13: Hydronic Cooling
    "@KDEkCaleffi-NQSG North America, LDQHB@ (MB Inc. 6 ,HKV@TJDD1C9850 South 54th Street ,HKV@TJDD 6HRBNMRHMFranklin, WI 53132 3 % T: 414.421.1000 F: 414.421.2878 Dear Hydronic and Plumbing Professional, Dear Hydronic Professional, Cooling a living space using chilled water is not new. Visit a high-rise hotel nd roomWelcome in summer, to the and2 edition notice ofhow idronics it is cooled. – Caleffi’s Chances semi-annual are that design cool journal air enters for fromhydronic a vent professionals.located in the wall or ceiling. Behind the vent is a heat exchanger withThe chilled 1st edition water of flowing idronics into was it. released The water in January absorbs 2007 the and heat distributed from room to airover and80,000 carries people it back in North to a chillerAmerica. that It extractsfocused onthe the heat topic and hydraulic rejects separation.it outside From thethe building. feedback After received, being it’sre-cooled, evident wethe attained water returns our goal back of explaining to the room— the benefits completingand proper the application cooling cycle. of this modern design technique for hydronic systems. A Technical Journal WithIf you advances haven’t inyet technology, received a copyhydronic of idronics cooling #1, is you no canlonger do solimited by sending to high- in the from risesattached and other reader large response commercial card, or buildings. by registering Improvements online at www.caleffi.us in chilled-water. The publication will be mailed to you free of charge. You can also download the Caleffi Hydronic Solutions generators,complete journaldistribution as a PDFequipment file from and our pipingWeb site.
    [Show full text]
  • Containment Housings, Room Side HEPA Modules, HEPA, ULPA, And
    Containment Housings, 100% Outside Air Rooftop Horizontal End Suction Room Side HEPA Units, and Split Systems Pumps, Vertical Inline Custom AHU’s, DX modules, HEPA, ULPA, Pumps, Integrated Drives, Fan Coils, SureFlow RTU’s and ERV’s. and ASHRAE Filters Booster Skids, Package Systems Desiccant Hydronics Dehumidification and Pool Dehumidification. Full Line of Condensing and Non-condensing Modular, Heat Recovery, Energy and Heat Recovery Domestic Water Heaters, TM Boilers Air-Cooled and Water- and MagLev Chillers, Equipment Hot Water Storage Tanks Cooled VRF, Ductless Central Plant Optimization Split Systems, Energy Recovery for VRF, VRF Controls Steam Specialties, Packaged Hydronic Configurable DX RTU’s Water Source Heat Pumps, Systems and ERV’s Geothermal Heat Pumps, Custom AHU’s, Fan Array Semi-Custom AHUs and Water-to-Water Chillers Retrofits, Penthouses, and ERVS Packaged Chiller Plants Air-Flow & Pressurization Fans & Blowers Commercial and Industrial Cold Room Dehumidifiers, Air Doors, Fabric Duct Measurement Stations Cooler Refrigeration, and Heat exchangers Cooler Panels Quality Industrial Fans and Booster coils, fan coils, Commercial Fans and Blowers Industrial Steam Boilers Light-Duty ERV's condenser coils, and DX coils Precision Dry Desiccant Dehumidifier AHU’s 1 / 3 Computer Room & Custom heat exchanger Critical Environment Active Chilled Beams and Mission Critical Air Pressure Independent coils Airflow Monitoring and Induction Air Conditioning Control Valves Control Systems for Medical, Laboratory, and Life Science Fabric
    [Show full text]
  • INSTALLATION OPERATION and SERVICE MANUAL Dynaforce® Series GAS FIRED COMMERCIAL CONDENSING STAINLESS STEEL TUBE BOILERS
    INSTALLATION OPERATION AND SERVICE MANUAL Dynaforce® Series GAS FIRED COMMERCIAL CONDENSING STAINLESS STEEL TUBE BOILERS HYDRONIC HEATING Models; DRH300, 350 400, 500, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2500, 3000, 3500, 4000, 4500, 5000 H HOT WATER HEATER Models; DRW300, 350 400, 500, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 2500, 3000, 3500, 4000, 4500, 5000 HLW WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS o Do not try to light any appliance, o Do not touch any electrical switch; do not use any phone in your building, o Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions, o If you cannot reach your gas supplier, call the fire department. Qualified installer, service agency or the gas supplier must perform installation and service. To the Installer: After installation, these instructions must be given to the end user or left on or near the appliance. To the End User: This booklet contains important information about this appliance. Retain for future reference. 6226 Netherhart Road, Mississauga, Ontario, L5T 1B7 99-0171 Rev. 0.7 Table of Contents PART 1 GENERAL INFORMATION............................................................................................................................... 1 1.1 INTRODUCTION ............................................................................................................................................
    [Show full text]
  • Installation, Operating, and Maintenance Manual Geothermal and Hydronics Specialists Geothermal Closed Loop Flush Cart
    www.geo-flo.com Geothermal and Hydronics Specialists Installation, Operating, and Maintenance Manual Part # 3833 Rev. 20MAR2017 Geothermal Closed Loop Flush Cart Geo-Flo Products Corporation Main Number: 812-275-8513 905 Williams Park Drive Toll Free: 800-784-8069 Bedford, Indiana 47421, U.S.A. Fax: 888-477-8829 3833-03-20-17 Installation, Operating, and Maintenance Manual Rev. 20MAR2017 Table of Contents General Description. 1 Technical Data . 1 Flush Cart Safety Information. 3 Flush Cart Diagram . 4 Flow Limiting Device . 5 Standard Flushing/Purging Procedure . 5 Power Flushing. .11 Fluid Filtering . .12 Adding Antifreeze. .14 Water Quality . .18 Emptying the Tank . .22 Maintenance. .22 Troubleshooting . .23 Warranty Information . .24 NOTES: This guide provides the installer with instructions specific to the Geo-Flo Flush Cart. Please refer to your heat pump manufacturer’s instructions or IGSHPA guidelines for additional detailed flushing, purging, and installation information. Please review the entire IOM document before proceeding with the installation. Geo-Flo Products Corporation is continually working to improve its products. As a result, the design and specifications of products in this catalog may change without notice and may not be as described herein. For the most up-to-date information, please visit our website, or contact our customer service department. Statements and other information contained in this document are not express warranties and do not form the basis of any bargain between the parties, but are merely Geo-Flo’s opinion or commendation of its products. FLUSH CART | 1 General Description The Geo-Flo Flush Cart is the professional’s choice to purge air and flush debris from residential and light commercial geother- mal ground loops.
    [Show full text]
  • Expansion Etiquette
    hydronics workshop JOHN SIEGENTHALER Expansion etiquette provides a “cushion” of air — a highly compressible Expansion tanks fluid — against which the expanding water can push without creating large pressure increases in the system. perform a simple but Think of the air in the tank as a spring. As the system’s water expands, this “spring” gets compressed. When vital function in all the water cools and contracts, the “spring” returns to its original condition. closed-loop hydronic SEPARATING AIR AND WATER Today, the most commonly specified expansion systems. tank for residential and light commercial systems uses a highly flexible butyl rubber or EPDM diaphragm to completely separate the air and water inside the tank. This diaphragm conforms to the internal steel surface hen water is heated, the space required of the tank when the air side is pressurized, as shown for each molecule increases. Any attempt in Figure 1. W to prevent this expansion will be met by When the system’s water is heated and expands into tremendous forces. If a strong metal container is com- the tank, the diaphragm deforms and moves toward pletely filled with liquid water and sealed from the the captive air chamber. The air pressure in the tank atmosphere, it will experience a rapid increase in pres- increases and so does the water pressure in the system. sure as the water is heated. If this pressure is allowed to However, if the tank is properly sized, the increase in build, that container will eventually burst. system pressure is not enough to cause the pressure To prevent such a result, closed-loop hydronic sys- relief valve to open, even when all the water in the sys- tems are equipped with an expansion tank.
    [Show full text]
  • Hydronics – Step by Step Heat Loss Example
    Hydronics – Step By Step Heat Loss Example • 10 x 15 room, 9’ ceilings 3x5 3x5 – Indoor design temp: 70 – Outdoor design temp: 0 – 2 outside walls – 15’ 6x5 Inf. Fac. = .018 – No heat above or below – U-Value = 1÷ R-Value – Window R-Value: 2.77 – U-Value = .36_ 10’ – R-19 in walls – U-Value =.05 – R-38 in ceiling – U-Value = .02 – R-19 in floor – U-Value = .05 • Infiltration = 10 L x 15 W x 9 H x 70 DTD x .018 Inf. fac. = 1701 BTUH • Windows = 60 x 70 DTD x .36 U = 1512 BTUH • Walls = 165 Net Area x 70 DTD x .05 U = 578 BTUH • Ceiling = 10 L x 15 W x 70 DTD x .02 U = 210 BTUH • Floor = 10 L x 15 W x 70 DTD x .05 U = 525 BTUH • Total Heat Load = 4,526 BTUH Boiler Sizing Terms • What’s the difference between DOE capacity and I-B-R Net Output? DOE capacity is a federal rating, and assumes the boiler is installed in a heated space and that all jacket and piping losses are usable and help offset the heating load. NET IBR rating assumes the boiler is installed in an unheated area, such as an unheated basement or garage, and that all jacket losses and piping losses are wasted. The NET IBR rating is an automatic 15% reduction of the DOE output. • What is “pickup” allowance? IBR includes “pickup” in the 15% output reduction of the DOE output. Pickup allows for the heating up of cold cast-iron boiler sections and cold steel pipe.
    [Show full text]
  • Building Automation Systems E Solutions Provides Building Automation to Our Clients Utilizing the Following Control Lines
    500 Wilson Pike Circle, Suite 106 • Brentwood, TN 37027 • Tel:(615)502-2059 • www.ESolutionsTN.com • Email:[email protected] Mitsubishi Carrier STULZ www.mehvac.com www.commercial.carrier.com www.stulz-ats.com Mitsubishi Electric Cooling & Heating provides a Full line of applied products including water and air Precision air conditioning for Computer Rooms and complete line of variable refrigerant flow zoning cooled chillers, air handlers, large rooftop and split Data Centers including in-row cooling and systems (City Multi) and mini-splits (Mr. Slim) systems, fan coils, self-contained units and controls ultrasonic humidifiers Haakon Munters Florida Heat Pump www.haakon.com www.munters.com www.fhp-mfg.com Custom Air Handlers for Healthcare, Education, Global leader in energy efficient air treatment High efficient WSHPs, 100% OA WSHPs; Industrial, and Commercial Applications utilizing heat recovery for the commercial and available in vertical, horizontal, down flow, RTU, industrial markets console, splits, and water to water configurations Acme Engineering & Manufacturing Corp. Hydro-Temp www.acmefan.com www.hydro-temp.com Leader in the manufacture of fans, blowers, and WSHPS specializing in geo-thermal applications ventilation equipment Reznor American Cooling Tower www.reznoronline.com www.americancoolingtower.com 100% OA units, gas fired make-up air equipment, Custom built cooling towers unit heaters, electric heaters and duct furnaces Cambridge Engineering Steril-Aire www.cambridge-eng.com www.steril-aire.com Direct fired heaters
    [Show full text]
  • Idronics 6: Solar Thermal Combisystems
    Idronics#6 Feat_rev2.indd 1 5/4/10 2:57:56 PM CaleffiCaleffi North North America, America, Inc. Inc. 98503883 South W. Milwaukee 54th Street Rd Franklin,Milwaukee, WI 53132 Wisconsin 53208 T:T: 414.421.1000414.238.2360 F: F: 414.421.2878 414.238.2366 Dear Hydronic Professional, Dear Hydronic Professional, Welcome to the 6th edition of idronics, Caleffi ’s semi-annual design journal Welcomefor hydronic to theprofessionals. 2nd edition of idronics – Caleffi’s semi-annual design journal for hydronic professionals. The global recession has slowed nearly all industries over the past year. TheHowever, 1st edition despite of idronicsdeclines was in construction, released in January solar water 2007 heater and distributed shipments to over 80,000in the US people increased in North 50% America. during 2008.It focused on the topic hydraulic separation. From the feedback received, it’s evident we attained our goal of explaining the benefits andAs more proper and application more HVAC of professionalsthis modern design become technique familiar forwith hydronic solar water systems. heating, many recognize opportunities to extend solar thermal technology A Technical Journal Iffor you combined haven’t domesticyet received hot a water copy andof idronics space heating#1, you applications.can do so by Thissending is a in the attachedtrend our reader parent response Caleffi SpA card, identifi or by ed registering several years online ago at in www.caleffi.us Europe, and is. The from publicationnow a topic willof growing be mailed interest to you here free inof North charge. America. You can For also this download reason, the Caleffi Hydronic Solutions completesolar “combisystems” journal as a PDF was fileselected from our as theWeb topic site.
    [Show full text]