Raising Bacnet® to the Next Level
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Transparent LAN Service Over Cable
Transparent LAN Service over Cable This document describes the Transparent LAN Service (TLS) over Cable feature, which enhances existing Wide Area Network (WAN) support to provide more flexible Managed Access for multiple Internet service provider (ISP) support over a hybrid fiber-coaxial (HFC) cable network. This feature allows service providers to create a Layer 2 tunnel by mapping an upstream service identifier (SID) to an IEEE 802.1Q Virtual Local Area Network (VLAN). Finding Feature Information Your software release may not support all the features documented in this module. For the latest feature information and caveats, see the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the Feature Information Table at the end of this document. Use Cisco Feature Navigator to find information about platform support and Cisco software image support. To access Cisco Feature Navigator, go to http://tools.cisco.com/ITDIT/CFN/. An account on http:// www.cisco.com/ is not required. Contents • Hardware Compatibility Matrix for Cisco cBR Series Routers, page 2 • Prerequisites for Transparent LAN Service over Cable, page 2 • Restrictions for Transparent LAN Service over Cable, page 3 • Information About Transparent LAN Service over Cable, page 3 • How to Configure the Transparent LAN Service over Cable, page 6 • Configuration Examples for Transparent LAN Service over Cable, page 8 • Verifying the Transparent LAN Service over Cable Configuration, page 10 • Additional References, page 11 • Feature Information for Transparent LAN Service over Cable, page 12 Cisco Converged Broadband Routers Software Configuration Guide For DOCSIS 1 Transparent LAN Service over Cable Hardware Compatibility Matrix for Cisco cBR Series Routers Hardware Compatibility Matrix for Cisco cBR Series Routers Note The hardware components introduced in a given Cisco IOS-XE Release are supported in all subsequent releases unless otherwise specified. -
Ieee 802.1 for Homenet
IEEE802.org/1 IEEE 802.1 FOR HOMENET March 14, 2013 IEEE 802.1 for Homenet 2 Authors IEEE 802.1 for Homenet 3 IEEE 802.1 Task Groups • Interworking (IWK, Stephen Haddock) • Internetworking among 802 LANs, MANs and other wide area networks • Time Sensitive Networks (TSN, Michael David Johas Teener) • Formerly called Audio Video Bridging (AVB) Task Group • Time-synchronized low latency streaming services through IEEE 802 networks • Data Center Bridging (DCB, Pat Thaler) • Enhancements to existing 802.1 bridge specifications to satisfy the requirements of protocols and applications in the data center, e.g. • Security (Mick Seaman) • Maintenance (Glenn Parsons) IEEE 802.1 for Homenet 4 Basic Principles • MAC addresses are “identifier” addresses, not “location” addresses • This is a major Layer 2 value, not a defect! • Bridge forwarding is based on • Destination MAC • VLAN ID (VID) • Frame filtering for only forwarding to proper outbound ports(s) • Frame is forwarded to every port (except for reception port) within the frame's VLAN if it is not known where to send it • Filter (unnecessary) ports if it is known where to send the frame (e.g. frame is only forwarded towards the destination) • Quality of Service (QoS) is implemented after the forwarding decision based on • Priority • Drop Eligibility • Time IEEE 802.1 for Homenet 5 Data Plane Today • 802.1Q today is 802.Q-2011 (Revision 2013 is ongoing) • Note that if the year is not given in the name of the standard, then it refers to the latest revision, e.g. today 802.1Q = 802.1Q-2011 and 802.1D -
Lonworks® Platform Revision 2
Introduction to the LonWorks® Platform revision 2 ® 078-0183-01B Echelon, LON, LonWorks, LonMark, NodeBuilder, , LonTalk, Neuron, 3120, 3150, LNS, i.LON, , ShortStack, LonMaker, the Echelon logo, and are trademarks of Echelon Corporation registered in the United States and other countries. LonSupport, , , OpenLDV, Pyxos, LonScanner, LonBridge, and Thinking Inside the Box are trademarks of Echelon Corporation. Other trademarks belong to their respective holders. Neuron Chips, Smart Transceivers, and other OEM Products were not designed for use in equipment or systems which involve danger to human health or safety or a risk of property damage and Echelon assumes no responsibility or liability for use of the Neuron Chips in such applications. Parts manufactured by vendors other than Echelon and referenced in this document have been described for illustrative purposes only, and may not have been tested by Echelon. It is the responsibility of the customer to determine the suitability of these parts for each application. ECHELON MAKES AND YOU RECEIVE NO WARRANTIES OR CONDITIONS, EXPRESS, IMPLIED, STATUTORY OR IN ANY COMMUNICATION WITH YOU, AND ECHELON SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Echelon Corporation. Printed in the United States of America. Copyright -
Introduction to Spanning Tree Protocol by George Thomas, Contemporary Controls
Volume6•Issue5 SEPTEMBER–OCTOBER 2005 © 2005 Contemporary Control Systems, Inc. Introduction to Spanning Tree Protocol By George Thomas, Contemporary Controls Introduction powered and its memory cleared (Bridge 2 will be added later). In an industrial automation application that relies heavily Station 1 sends a message to on the health of the Ethernet network that attaches all the station 11 followed by Station 2 controllers and computers together, a concern exists about sending a message to Station 11. what would happen if the network fails? Since cable failure is These messages will traverse the the most likely mishap, cable redundancy is suggested by bridge from one LAN to the configuring the network in either a ring or by carrying parallel other. This process is called branches. If one of the segments is lost, then communication “relaying” or “forwarding.” The will continue down a parallel path or around the unbroken database in the bridge will note portion of the ring. The problem with these approaches is the source addresses of Stations that Ethernet supports neither of these topologies without 1 and 2 as arriving on Port A. This special equipment. However, this issue is addressed in an process is called “learning.” When IEEE standard numbered 802.1D that covers bridges, and in Station 11 responds to either this standard the concept of the Spanning Tree Protocol Station 1 or 2, the database will (STP) is introduced. note that Station 11 is on Port B. IEEE 802.1D If Station 1 sends a message to Figure 1. The addition of Station 2, the bridge will do ANSI/IEEE Std 802.1D, 1998 edition addresses the Bridge 2 creates a loop. -
L-IP User Manual 11 LOYTEC
L-IP CEA-709/IP Router User Manual LOYTEC electronics GmbH Contact LOYTEC electronics GmbH Blumengasse 35 1170 Vienna AUSTRIA/EUROPE [email protected] http://www.loytec.com Version 7.4 Document № 88065915 LOYTEC MAKES AND YOU RECEIVE NO WARRANTIES OR CONDITIONS, EXPRESS, IMPLIED, STATUTORY OR IN ANY COMMUNICATION WITH YOU, AND LOYTEC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS PRODUCT IS NOT DESIGNED OR INTENDED FOR USE IN EQUIPMENT INTENDED FOR SURGICAL IMPLANT INTO THE BODY OR OTHER APPLICATIONS INTENDED TO SUPPORT OR SUSTAIN LIFE, FOR USE IN FLIGHT CONTROL OR ENGINE CONTROL EQUIPMENT WITHIN AN AIRCRAFT, OR FOR ANY OTHER APPLICATION IN WHICH IN THE FAILURE OF SUCH PRODUCT COULD CREATE A SITUATION IN WHICH PERSONAL INJURY OR DEATH MAY OCCUR. LOYTEC MAKES NO REPRESENTATION AND OFFERS NO WARRANTY OF ANY KIND REGARDING OF ANY THIRDPARTY COMPONENTS MENTIONED IN THIS MANUAL. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of LOYTEC. LC3020, L-Chip, L-Core, L-DALI, L-GATE, L-INX, L-IOB, LIOB-Connect, LIOB-FT, L-IP, LPA, L-Proxy, L-Switch XP, L- Term, L-VIS, L-WEB, L-ZIBI and ORION™ stack are trademarks of LOYTEC electronics GmbH. LonTalk®, LONWORKS®, Neuron®, LONMARK®, LonMaker®, i.LON®, and LNS® are trademarks of Echelon Corporation registered in the United States and other countries. L-IP CEA-709 User Manual 3 LOYTEC Contents 1 Introduction ............................................................................................... -
Network & Wireless
NETWORK & WIRELESS HUMIDITY & WIRELESS Kele Has Doubled the Offering of Network and Wireless Solutions, NETWORK and Continues to Add to Our Options to Meet Your Needs. Babel Buster | p. 719 L-VIS Series | p. 721 BASRT-B | p. 727 Series 110A | p. 733 ValuPoint VP4-23 | p. 744 EKI Series | p. 738 Series NETWORK & WIRELESS Products manufactured MODEL/SERIES PAGE in the United States Network Display and Control Panels Wireless EnOcean and ZigBee Devices L-VIS Series — BACnet and LON Touch Panel . 721 and Systems (cont.) Products that are BBC-SD — BACnet Graphic Display . 724 E3T-SxE Series — EnOcean Wireless European new to the catalog WebOP Series — Touchscreen Operator Display Light Switches . 826 Panel . 725 E3T-S2H Series — EnOcean Wireless Handheld Remote . 827 Network Gateways EasySens Thanos — EnOcean Room Operating ETH-1000 — Provides connectivity between Ethernet Panel . .. 830 and RS-485 based networks . 713 EasySens Receiver Gateways — EnOcean Receiver XLTR-1000 — Provides Connectivity Between Two Gateways . 831 Rs-485 Based Networks . 714 EasySens SRC Receiver Controllers — EnOcean Raptor Protocol Converter — RLE Technologies Receiver Controllers . 832 Protocol Coverter . 715 EasySens Repeater — EnOcean Wireless LGATE-9xx Series — Lonworks/Bacnet And Repeater . 833 Universal Gateways . 717 EasySens Switches — EnOcean Lighting, Blinds Babel Buster Series — BACnet - Modbus - SNMP and Shutters Switches . 834 Gateways . 719 EasySens Specialty Wireless Transmitters — AddMe® Series — BACnet - Modbus Network I/O . 743 EnOcean Remote Control, Key Card Switch, Window/Door Contact . 835 Network I/O Modules EasySens Room Sensors — EnOcean Temperature, Humidity and CO2 Sensors . 836 L-IOB Series — BACnet and LON I/O Module . 739 EasySens Temperature Sensors — EnOcean i.CanDoIt Series — Embedded Network Servers 742 Surface, Duct, Remote and Outdoor AddMe® Series — BACnet - Modbus Network I/O . -
Layer 2 Virtual Private Networks CM-SP-L2VPN-I11-130808
Data-Over-Cable Service Interface Specifications Business Services over DOCSIS® Layer 2 Virtual Private Networks CM-SP-L2VPN-I11-130808 ISSUED Notice This DOCSIS specification is the result of a cooperative effort undertaken at the direction of Cable Television Laboratories, Inc. for the benefit of the cable industry and its customers. This document may contain references to other documents not owned or controlled by CableLabs®. Use and understanding of this document may require access to such other documents. Designing, manufacturing, distributing, using, selling, or servicing products, or providing services, based on this document may require intellectual property licenses from third parties for technology referenced in this document. Neither CableLabs nor any member company is responsible to any party for any liability of any nature whatsoever resulting from or arising out of use or reliance upon this document, or any document referenced herein. This document is furnished on an "AS IS" basis and neither CableLabs nor its members provides any representation or warranty, express or implied, regarding the accuracy, completeness, noninfringement, or fitness for a particular purpose of this document, or any document referenced herein. Cable Television Laboratories, Inc., 2006-2013 CM-SP-L2VPN-I11-130808 Data-Over-Cable Service Interface Specifications DISCLAIMER This document is published by Cable Television Laboratories, Inc. ("CableLabs®"). CableLabs reserves the right to revise this document for any reason including, but not limited to, changes in laws, regulations, or standards promulgated by various agencies; technological advances; or changes in equipment design, manufacturing techniques, or operating procedures described, or referred to, herein. CableLabs makes no representation or warranty, express or implied, with respect to the completeness, accuracy, or utility of the document or any information or opinion contained in the report. -
7-Port Gigabit Ethernet Switch with Audio Video Bridging and Two RGMII/MII/RMII Interfaces
KSZ9567R 7-Port Gigabit Ethernet Switch with Audio Video Bridging and Two RGMII/MII/RMII Interfaces Highlights • Five Integrated PHY Ports - 1000BASE-T/100BASE-TX/10BASE-Te IEEE 802.3 • Non-blocking wire-speed Ethernet switching fabric - Fast Link-up option significantly reduces link-up time • Full-featured forwarding and filtering control, includ- - Auto-negotiation and Auto-MDI/MDI-X support ing Access Control List (ACL) filtering - On-chip termination resistors and internal biasing for • Full VLAN and QoS support differential pairs to reduce power • Five ports with integrated 10/100/1000BASE-T PHY - LinkMD® cable diagnostic capabilities for determining transceivers cable opens, shorts, and length • Two ports with 10/100/1000 Ethernet MACs and con- • Advanced Switch Capabilities figurable RGMII/MII/RMII interfaces - IEEE 802.1Q VLAN support for 128 active VLAN • IEEE 1588v2 Precision Time Protocol (PTP) support groups and the full range of 4096 VLAN IDs - IEEE 802.1p/Q tag insertion/removal on per port basis • IEEE 802.1AS/Qav Audio Video Bridging (AVB) - VLAN ID on per port or VLAN basis • IEEE 802.1X access control support - IEEE 802.3x full-duplex flow control and half-duplex • EtherGreen™ power management features, back pressure collision control including low power standby - IEEE 802.1X access control 2 • Flexible management interface options: SPI, I C, (Port-based and MAC address based) MIIM, and in-band management via any port - IGMP v1/v2/v3 snooping for multicast packet filtering • Industrial temperature range support - IPv6 -
Analysis of Qos in Software Defined Wireless Network with Spanning Tree Protocol
I. J. Computer Network and Information Security, 2017, 6, 61-68 Published Online June 2017 in MECS (http://www.mecs-press.org/) DOI: 10.5815/ijcnis.2017.06.07 Analysis of QoS in Software Defined Wireless Network with Spanning Tree Protocol Rafid Mustafiz, Abu Sayem Mohammad Delowar Hossain, Nazrul Islam+, Mohammad Motiur Rahman Department of Computer Science and Engineering +Department of Information and Communication Technology Mawlana Bhashani Science and Technology University, Santosh, Tangail-1902, Bangladesh E-mail: [email protected], [email protected], [email protected], [email protected] Abstract—Software Defined Network (SDN) is more technique. The data controlling actions are controlled by dynamic, manageable, adaptive and programmable a software or hardware based centralized controller and network architecture. This architecture separates the data forwarding task has performed by a hardware core control plane from the forwarding plane that enables the device [3]. This enables the control plane to be directly network to become directly programmable. The programmable which makes it suitable in the field of programmable features of SDN technology has research. Data plane functionality contains features such dramatically improved network efficiency and simplify as quality of service (QoS) [4]. The overall performance the network configuration and resource management. of a network topology depends mostly on the parameters SDN supports Open-Flow technology as forwarding of QoS. The present goal of SDN is to design a network function and centralized control successfully. Wireless that is capable the maximum improvement of QoS environment has recently added to the SDN infrastructure parameters. SDN supports many new types of that has rapidly emerged with Open-Flow protocol. -
System Controllers PXC001.D PXC001-E.D PXA40-RS
s 9223 Desigo™ PX System controllers PXC001.D PXC001-E.D PXA40-RS... for the integration of third-party devices and systems in Desigo • Integration platforms and system controllers for third-party devices and systems via KNX, Modbus, M-Bus and other protocols into the automation level via BACnet • System controllers for the integration of Desigo RXB/RXL room controllers • Native BACnet devices with communication via BACnet/LonTalk or BACnet/IP • BTL label (BACnet communications passed the BTL test) • Comprehensive management and system functions (alarm management, time scheduling, trends, remote management, access protection etc.) • Supports operation via local or network-compatible operator units PXM… CM1N9223en_08 2017-04-11 Building Technologies Use • The system controllers support the integration of Desigo RXB/RXL room controllers as well as third-party devices and systems via KNX, Modbus or M- Bus etc. in the automation level using BACnet/LonTalk or BACnet/IP • Mapping and monitoring of third-party disciplines as HVAC, light, SPS etc. • Functionality as freely programmable system controllers for standard or proprietary protocol applications Functions • The system controllers provide the infrastructure to hold and execute the system and application specific functions. They are freely programmable. • Comprehensive management and system functions are available: − Alarm management − Time scheduling − Trends − Access protection Type summary System controllers Type System-Controller for the integration of KNX, M-Bus, Modbus PXC001.D or -
Open Systems for Homes and Buildings: Comparing Lonworks and KNX Alan Kell Peter Colebrook I&I Limited
Open Systems for Homes and Buildings: Comparing LonWorks and KNX Alan Kell Peter Colebrook i&i limited No part of this publication may be transmitted or reproduced in any form or by any means, electronic or mechanical, for any purpose, without the prior written permission of i&i limited. Trademarks and Logos i&i and Proplan are trademarks of i&i limited. KNX, EIB, European Installation Bus, EHS, European Home Systems and BatiBUS are trademarks of The Konnex Association and its constituent associations; European Installation Bus Association (EIBA), European Home Systems Association (EHSA) and Club BatiBUS International (BCI). Echelon, LON, LONWORKS, LONMARK, LonBuilder, NodeBuilder, LonManager, LonTalk, LonUsers, LonPoint, Digital Home, Neuron, 3120, 3150, LNS, i.LON, LONWORLD, the Echelon logo, and the LonUsers logo are trademarks of Echelon Corporation registered in the United States and other countries. LonMaker, Panoramix, and Networked Energy Services Powered by Echelon are trademarks of Echelon Corporation. All other brand names and product names are trademarks or registered trademarks of their respective holders. About i&i limited Alan Kell was the principal author of the 1993 study by DEGW etl1 entitled “Bus Systems for Building Control” which was the first detailed study in this area to compare, among others, EIB and LONWORKS in the context of building control. Peter Colebrook collaborated closely with Siemens in Regensburg in the late 1980’s, was one of the 12 founder signatories of the European Installation Bus Association (EIBA) and subsequently served as a Director of that Association. He was also one of the founders of the LONMARK Interoperability Association and similarly served as a Director of that Association. -
V1.1.1 (2014-09)
Final draft ETSI ES 203 385 V1.1.1 (2014-09) ETSI STANDARD CABLE; DOCSIS® Layer 2 Virtual Private Networking 2 Final draft ETSI ES 203 385 V1.1.1 (2014-09) Reference DES/CABLE-00008 Keywords access, broadband, cable, data, IP, IPcable, L2VPN, modem ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88 Important notice The present document can be downloaded from: http://www.etsi.org The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http://portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI.