Correction of the Eye's Wave Aberration

Total Page:16

File Type:pdf, Size:1020Kb

Correction of the Eye's Wave Aberration Adaptive Optics for Vision Science and Astronomy ASP Conference Series, Vol. **VOLUME**, **PUBLICATION YEAR** A. Quirrenbach Correction of the Eye’s Wave Aberration Yasuki Yamauchi∗, David R. Williams∗,, Jason Porter∗,, and Antonio Guirao∗,† ∗ Center for Visual Science, University of Rochester, Rochester, New York, 14627, USA The Institute of Optics, University of Rochester, Rochester, New York, 14627, USA † Laboratorio de Optica, Universidad de Murcia, Campus de Espinardo (Edificio C), 30071 Murcia, SPAIN 1. Introduction We have seen in the previous two chapters that the human eye is not a perfect optical system and contains a host of different aberrations. If the eye’s opti- cal quality is poor, i.e. if the images formed on the retina are blurred or have low contrast, vision will be deficient even if the rest of the visual system were perfect. Several methods to improve the optics of the human eye have been proposed and developed, the earliest written reports of which originated at least 700 years ago. Spectacles that corrected defocus were invented as early as the 13th century (Willoughby Cashell, 1971; Rubin, 1986) while spectacles that cor- rected defocus and astigmatism were conceived in the 19th century (Helmholtz, 1924). Since then, there has been relatively little work on exploring techniques to correct additional aberrations in the eye. In 1961, Smirnov suggested that it might be possible to manufacture customized contact lenses that would com- pensate for the higher order aberrations found in individual eyes. Recently, technological advances in measuring and compensating for the aberrations of the human eye have made it possible to provide the eye with unprecedented optical quality (Liang et al., 1997). An observer viewing the world through a “super-correcting” device can see sharper, higher-contrast images than they have ever seen before. In this chapter, we describe several methods for correct- ing the eye’s higher order aberrations, including adaptive optics. In addition, the benefits of correcting higher order aberrations and the constraints imposed by the higher order correction method will also be discussed. 2. Methods for Correcting Higher Order Aberrations The most conventional methods used to correct the aberrations of the eye have been spectacles and contact lenses. Traditionally, these methods have only com- pensated for defocus and astigmatism (or known in the trade as sphere and cylinder). Now recent developments in technology have made it possible to investigate the prospects for eliminating higher order aberrations as well. In this section, we will briefly explain several methods for correcting higher order aberrations. 93 94 Y. Yamauchi, D.R. Williams, J. Porter, A. Guirao 2.1. Contact lenses Conventional contact lenses correct refractive errors by adding or subtracting focusing power to the eye. While these lenses typically correct for only three constituent aberrations (one defocus and two astigmatic Zernike modes), wave aberrations have been measured using a Hartmann-Shack wavefront sensor that include as many as 65 different Zernike aberrations (Liang et al., 1997). With the development of lathing and laser ablative techniques that can sculpt arbitrary surfaces on contact lenses, it may be possible to create a customized contact lens having an aberration profile that exactly compensates for the wave aberration of an individual eye. The performance of a customized lens will be sensitive to slight rotations and decentrations of the lens as it moves on the eye. However, early studies have theoretically shown that image quality is only slightly reduced when a customized contact lens experiences rotations and decentrations of the same magnitude as those typically found in soft contact lenses (Guirao et al., 2000a, 2001). 2.2. Laser refractive surgery and intraocular lenses Another way to correct the eye’s aberrations, instead of adding a complementary optical system to it, is to physically change the eye’s optics. Laser refractive surgery is a general term for a surgical procedure that can alter the eye’s optics by permanently changing the shape of the cornea. Photorefractive keratectomy, or PRK, and laser-assisted in situ keratomileusis, or LASIK, are the most popular methods in laser refractive surgery. These techniques, shown in Fig. 1, are currently used to remove defocus (myopia and hyperopia) and low to moderate degrees of astigmatism. The principle of these methods is to eliminate corneal tissue and change the curvature of the cornea so that light can focus exactly on the retina. PRK is done by the use of a laser which precisely reshapes the cornea’s front surface. In LASIK, the surgeon uses a micro-keratome to cut a thin corneal flap and pulls this flap off of the cornea, exposing the underlying tissue. The surgeon then uses an excimer laser to remove this underlying tissue and reattaches the flap after the ablation. There is an ongoing effort to refine laser refractive surgery to correct other defects besides conventional refractive errors (MacRae et al., 2000). With wavefront sensing and corneal topography (a technique that determines the shape and thickness of the cornea), it’s possible to determine how to alter the shape of cornea in order to minimize the residual wave aberration of the eye. Thus, refractive surgery provides an alternative method for correcting the higher order aberrations of the eye. In contrast with a contact lens, the effects of this surgical treatment are permanent. However, the cornea is a living structure and will change shape after surgery due to healing mechanisms that are not entirely understood. Instead of reshaping the cornea of the eye, it is also possible to replace the eye’s lens with an intraocular lens that compensates for the aberrations caused by the entire optical system. In this method, it is possible to measure all the aberrations and make an artificial lens that compensates them to minimize the residual aberrations. Correction of the Eye’s Wave Aberration 95 Figure 1. Schematic illustration of two types of refractive surgeries, (a): PRK, in which an excimer laser directly ablates the first surface of the cornea, and (b) LASIK, in which a corneal flap is cut and lifted, allowing the excimer laser to ablate the underlying corneal tissue (cited from Gimbel Eye Centre web page). 2.3. Adaptive optics All of the aforementioned techniques provide a static correction of the eye’s aberrations, usually for distance vision. Real-time correction of higher order aberrations can be reliably achieved using adaptive optics, a technique first introduced to vision by Liang and Williams (Liang & Williams, 1997). A de- formable mirror is used to correct the eye’s wave aberration without physically altering the cornea or any of the eye’s optical components. Once the eye’s optics are corrected, one may non-invasively image the retina at a microscopic scale or experimentally measure the improvement in visual performance that subjects experience when their higher order aberrations are corrected. 3. Adaptive Optics for the Human Eye 3.1. System design Fig. 2 shows the schematic diagram of the adaptive optics system for the human eye at the University of Rochester. The system contains a Hartmann-Shack wavefront sensor used to measure the wave aberration of the eye and a wavefront corrector used to compensate for these aberrations. In addition, the system has two separate arms that allow for vision testing and retinal imaging. The adaptive optics part of the 1st generation system is a deformable mirror (Xinetics, Inc.) with 37 actuators that can independently push and pull on the mirror to warp it’s surface into an appropriate shape to compensate for the eye’s aberrations. The stroke of each actuator is ± 2 µm, allowing for a total wavefront shift of 8 µm upon reflection. Because the eye is not a perfect optical system, light exiting the eye’s pupil from a point source on the retina does not emerge as a 96 Y. Yamauchi, D.R. Williams, J. Porter, A. Guirao Figure 2. Schematic illustration of an adaptive optics system for vision. Figure 3. Adaptive optics system at University of Rochester. planar wavefront, but as an aberrated wavefront. The shape of this aberrated wavefront, which varies from eye to eye, can be measured with a Hartmann- Shack wavefront sensor. A computer then converts the spot positions obtained with the wavefront sensor into a control signal for the deformable mirror. Aberration compensation is achieved with a closed-loop feedback control at frame rates of up to 30 Hz using a direct-slope algorithm. In each loop, the mirror stroke is directly computed from the local slopes of the wavefront, as de- termined by the wavefront sensor. Wavefront correction is performed until the root-mean-square (RMS) wavefront error is reduced to a pre-determined value, or levels off at a minimum value. 10 to 20 loops are usually needed to achieve the best correction and an entire closed-loop correction requires less than 1 second. Fig. 3 shows a picture of the adaptive optics system used at the University of Rochester. Correction of the Eye’s Wave Aberration 97 3.2. System performance Wave aberrations and their associated point spread functions (PSF) are shown in Fig. 4 for an aberration-free, or perfect, eye and for three normal subjects over a 6.8 mm pupil. As illustrated in this figure, both the wave aberration and PSF can vary tremendously from person to person. Fig. 5 illustrates the Figure 4. Wave aberrations and the PSF calculated from the wave aberra- tion for three subjects (6.8 mm pupil). For comparison, the diffraction limited case, shown on the left of the figure, represents an aberration-free, or perfect, eye. Figure 5. Wave aberrations of two subjects before (left panels) and after (right panels) adaptive compensation across a 6 mm pupil.
Recommended publications
  • Higher-Order Wavefront Aberration and Letter-Contrast Sensitivity In
    Eye (2008) 22, 1488–1492 & 2008 Macmillan Publishers Limited All rights reserved 0950-222X/08 $32.00 www.nature.com/eye 1 1 2 2 CLINICAL STUDY Higher-order C Okamoto , F Okamoto , T Samejima , K Miyata and T Oshika1 wavefront aberration and letter-contrast sensitivity in keratoconus Abstract Keywords: keratoconus; wavefront aberration; higher-order aberration; contrast sensitivity; Aims To evaluate the relation between letter-contrast sensitivity higher-order aberration of the eye and contrast sensitivity function in eyes with keratoconus. Methods In 22 eyes of 14 patients with Introduction keratoconus (age 30.578.4 years, means7SD) and 26 eyes of 13 normal controls (age Keratoconus is a chronic, non-inflammatory 29.276.7 years), ocular higher-order wavefront disease of the cornea associated with aberration for a 6-mm pupil was measured progressive thinning and anterior protrusion of with the Hartmann-Schack aberrometer the central cornea.1,2 Irregular astigmatism is (KR-9000 PW, Topcon). The root mean square often the first and most apparent clinical finding (RMS) of third- and fourth-order Zernike in keratoconus, and this is evidenced by a coefficients was used to represent higher-order distortion of the corneal image as noted with aberrations. The letter-contrast sensitivity was the placido disc, retinoscope, keratometer, examined using the CSV-1000LV contrast chart keratoscope, and computerized (Vector Vision). videokeratograph. Previous studies using Results In the keratoconus group, the videokeratography have quantitatively 1 Department of letter-contrast sensitivity showed significant demonstrated that corneal irregular Ophthalmology, Institute of correlation with third-order (Spearman’s astigmatism is significantly greater in eyes with Clinical Medicine, University correlation coefficient ¼À0.736, 0.001) 3–6 of Tsukuba, Ibaraki, Japan r Po keratoconus than in normal eyes.
    [Show full text]
  • Measuring Higher Order Optical Aberrations of the Human Eye: Techniques and Applications
    Brazilian Journal of Medical and Biological Research (2002) 35: 1395-1406 Optical aberrations of the human eye 1395 ISSN 0100-879X Measuring higher order optical aberrations of the human eye: techniques and applications L. Alberto V. Carvalho1, 1Grupo de Óptica, Instituto de Física de São Carlos, Universidade de São Paulo, J.C. Castro1 and São Carlos, SP, Brasil L. Antonio V. Carvalho2 2Departamento de Matemática, Universidade Estadual de Maringá, Maringá, PR, Brasil Abstract Correspondence In the present paper we discuss the development of wave-front, an Key words L. Alberto V. Carvalho instrument for determining the lower and higher optical aberrations of · Optical aberrations Grupo de Óptica, IFSC, USP the human eye. We also discuss the advantages that such instrumenta- · Corneal topography 13560-900 São Carlos, SP tion and techniques might bring to the ophthalmology professional of · Zernike polynomials Brasil the 21st century. By shining a small light spot on the retina of subjects · Refractive surgery E-mail: [email protected] and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberra- Research partially supported by FAPESP (Nos. 01/03132-8 and tions (astigmatism, myopia, hyperopia) and higher order aberrations 00/06810-4). L. Antonio V. Carvalho (coma, spherical aberration, etc.). We have measured artificial eyes is partially supported by CNPq with calibrated ametropia ranging from +5 to -5 D, with and without (No. 304041/85-8). 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS) sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes.
    [Show full text]
  • Total, Corneal, and Internal Ocular Optical Aberrations in Patients with Keratoconus
    Total, Corneal, and Internal Ocular Optical Aberrations in Patients With Keratoconus Zuzana Schlegel, MD; Yara Lteif, MD; Harkaran S. Bains; Damien Gatinel, MD, PhD he front corneal surface is a major refracting com- ABSTRACT ponent of the eye and is considerably distorted in 1 PURPOSE: To measure and compare total, corneal, and T patients with keratoconus. Asymmetric corneal internal ocular aberrations using combined wavefront protrusion is the primary cause of irregular astigmatism in analysis and corneal topography in eyes with keratoco- keratoconus.2 This deformity affects both the anterior and nus and eyes with normal corneas. posterior corneal surfaces.3-5 Recent studies have investigated the contribution of the posterior surface to the overall corneal METHODS: This prospective study comprised eyes of optical performance by analyzing data obtained with slit- patients with keratoconus and myopic patients seeking 6 7 refractive surgery. Patients diagnosed with keratoconus scanning or Scheimpfl ug topography. Signifi cantly larger and with a classifi cation of “normal” or “keratoconus” amounts of posterior corneal aberrations and higher compen- on the NIDEK Corneal Navigator corneal disease screen- sation effects were observed in keratoconic eyes compared ing software were selected for inclusion in this study. to normal eyes.6,7 Both the posterior corneal aberrations and The normal group comprised eyes with a “normal” clas- crystalline lens aberrations contribute to the internal aberra- sifi cation with 99% similarity. In the normal group, only one eye per patient was randomly selected based on tion component. a randomization schedule. Corneal, internal, and total Recent studies have found that in pre-presbyopic patients, wavefront measurements were provided by the NIDEK the magnitude of higher order aberrations for the cornea or OPD-Scan II.
    [Show full text]
  • Articles Induced Optical Aberrations Following Formation of a Laser in Situ Keratomileusis Flap
    articles Induced optical aberrations following formation of a laser in situ keratomileusis flap Ioannis G. Pallikaris, MD, PhD, George D. Kymionis, MD, PhD, Sophia I. Panagopoulou, Charalambos S. Siganos, MD, PhD, Michalis A. Theodorakis, Aristofanis I. Pallikaris Purpose: To determine how refractive error, visual acuity, and high-order aberra- tions (3rd- and 4th-order) are affected by the formation of a lamellar corneal flap during laser in situ keratomileusis (LASIK). Setting: University refractive surgery center. Methods: The effect of lamellar corneal flap formation was analyzed in 15 myopic eyes (mean preoperative refraction Ϫ4.72 diopters [D] [range Ϫ1.25 to Ϫ7.25 D]). The flap was created using a 2-step procedure: (1) a nasally hinged lamellar cor- neal flap was created; (2) the flap was lifted and stromal ablation performed 2 months after the flap was made. A Hartmann-Shack aberrometer was used to measure the aberrations. Results: There was no significant change in the refractive error (spherical equiva- lent pre-flap Ϫ4.72 Ϯ 1.99 D and post-flap Ϫ4.62 Ϯ 1.99 D [P ϭ .28]) or visual acuity (pre-flap uncorrected visual acuity [UCVA] 0.07 and best corrected visual acuity [BCVA] 0.96; post-flap UCVA 0.08 and BCVA 0.95 [P ϭ .16 and P ϭ .33, respectively]). A statistically significant increase in total higher-order wavefront aberrations was observed following flap formation (root mean square pre-flap 0.344 Ϯ 0.125 and post-flap 0.440 Ϯ 0.221 [P ϭ .04]). Conclusion: Flap formation during LASIK can modify the eye’s existing natural higher-order aberrations (especially spherical and coma-like aberrations along the axis of the flap’s hinge), while visual acuity and refractive error remain unaffected.
    [Show full text]
  • Ocular Higher-Order Aberrations and Mesopic Pupil Size in Individuals
    HOAsandpupilsizeinindividuals 窑ClinicalResearch窑 Ocularhigher-orderaberrationsandmesopicpupil sizeinindividualsscreenedforrefractivesurgery 1EyeResearchcenter,RasoulAkramHospitalTehran hyperopescomparedtomyopes.Mesopicpupilsizewas UniversityofMedicalSciences,Tehran,Iran largerinmyopicgroup. 2DepartmentofEpidemiologyandBiostatistics,Schoolof ·KEYWORDS:cornealwavefrontaberration;pupil;mesopic PublicHealth,TehranUniversityofMedicalSciences, vision;race;myopia;hyperopia Tehran,Iran DOI:10.3980/j.issn.2222-3959.2012.02.21 Correspondenceto: MohammadSoleimani.EyeResearch Center,RassoulAkramHospital,TehranUniversityof HashemianSJ,SoleimaniM,ForoutanA,JoshaghaniM,Ghaempanah MedicalSciences,Tehran,[email protected] MJ,JafariME,YaseriM.Ocularhigher-orderaberrationsand Received:2011-08-23Accepted:2012-03-10 mesopicpupilsizeinindividualsscreenedforrefractivesurgery. 2012;5(2):222-225 Abstract INTRODUCTION AIM:Tostudythedistributionofocularhigher-order · cularaberrationsmayplayamajorroleintheimage aberrations(HOAs)andmesopicpupilsizeinindividuals O formationintheocularopticalsystem.Lowerorder screenedforrefractivesurgery. aberrationssuchasastigmatismanddefocuscaneasilybe · METHODS:OcularHOAsandmesopicpupilsizewere correctedandmaybelessproblematic,howeverhigher studiedin2458eyesof1240patientswithmyopia,myopic orderaberrations(HOAs)cancausemoredegradationofthe astigmatismandcompoundmyopicastigmatismand215eyes visualperformance[1-5]. of110patientswithhyperopia,hyperopicastigmatismand Customizedcornealablationhasbeensuccessfullyusedto compoundhyperopic
    [Show full text]
  • Visual Benefit of Correcting Higher Order Aberrations of the Eye
    Visual Benefit of Correcting Higher Order Aberrations of the Eye David Williams, PhD; Geun-Young Yoon, PhD; Jason Porter, MS; Antonio Guirao, PhD; Heidi Hofer, BS; Ian Cox, PhD ABSTRACT patient's refraction is also a prescription for improv- There is currently considerable debate concern- ing retinal image quality. But the conventional ing the visual impact of correcting the higher order refraction attempts to specify what is wrong with aberrations of the eye. We describe new measure- ments of a large population of human eyes and com- the eye using only three parameters (sphere, cylin- pute the visual benefit of correcting higher order der, and axis), whereas the wave aberration speci- aberrations. We also describe the increase in con- fies the errors in the eye with many more parame- trast sensitivity when higher order aberrations are ters. Wave front sensors have been built that cap- corrected with an adaptive optics system. All these ture as many as 65 components in the wave aberra- results suggest that many, though not all, observers 2 with normal vision would receive worthwhile tion. This article addresses the question whether improvements in spatial vision from customized correcting higher order aberrations as well as defo- vision correction, at least over a range of viewing cus and astigmatism can lead to real improvements distances and particularly when the pupils are in vision in everyday life. Do the visual benefits of large. Keratoconic patients or patients suffering correcting higher order aberrations warrant the from spherical aberration as a result of laser refractive surgery as it is presently performed refinement of technologies for vision correction, would especially benefit.
    [Show full text]
  • Ocular Aberrations and Visual Quality in Aspheric and Multifocal Contact Lenses
    From the Department of Clinical Neuroscience Section of Ophthalmology and Vision Unit of Optometry Karolinska Institutet, Stockholm, Sweden OCULAR ABERRATIONS AND VISUAL QUALITY IN ASPHERIC AND MULTIFOCAL CONTACT LENSES Anna Lindskoog Pettersson Stockholm 2011 All previously published papers were reproduced with permission from the publishers. Cover photo: Jessika Runolf Published by Karolinska Institutet. Printed by [name of printer] © Anna Lindskoog Pettersson, 2011 ISBN 978-91-7457-418-0 Printed by 2011 Gårdsvägen 4, 169 70 Solna To -Erik, my star -Sofia, my sunshine -Ove, my love ABSTRACT Good visual quality and precise accommodation are required to be able to focus objects at distance and near, and are essential in order to be able to perform most tasks in life. Most eyes are not ideal eyes, i.e., they have different refractive errors which distort the produced image. The well-known refractive errors (lower order aberrations), myopia, hyperopia and astigmatism, have long been correctable. In addition to these common errors, irregularities in the refractive media create higher order aberrations, which are described by the Zernike polynomials. To achieve a higher level of visual quality, it is important to correct aberrations. Spherical aberration and chromatic aberration, present in polychromatic light, serve as cues for accurate accommodation in order to provide a clear image of the object. It is of interest to know how a reduction or increase of certain aberrations might affect visual quality and accommodation. The aim of this project was to develop techniques to measure the changes in optical aberrations and accommodation in subjects while wearing standard contact lenses, and lenses with aberration control and to find new strategies to enhance the fitting of these lenses in order to achieve a higher level of visual quality.
    [Show full text]
  • Aberrations of the Human Eye: Structure
    Aberrations of the human eye: Structure Jason Porter Advisor: David R. Williams March 20, 2003 The Institute of Optics and Center for Visual Science University of Rochester Classical Eye Models Gullstrand #1 Schematic Eye (1911) Radii of Curvature (Relaxed Eye) Radii of Curvature (Accommodated Eye) Anterior cornea = 7.7 mm Anterior cornea = 7.7 mm Posterior cornea = 6.8 mm Posterior cornea = 6.8 mm Anterior lens = 10.0 mm Anterior lens = 5.33 mm Anterior lens core = 7.911 mm Anterior lens core = 2.655 mm Posterior lens core = -5.76 mm Posterior lens core = -2.655 mm Posterior lens = -6.0 mm Posterior lens = -5.33 mm Goss and West. Introduction to the Optics of the Eye. 2002. Atchison and Smith. Optics of the Human Eye. 2000. Classical Eye Models Schematic eye Simplified schematic eye Reduced eye (4 refracting surfaces) Gullstrand-Emsley (1 refracting surface) Simplified Gullstrand #2 (1911) (3 refracting surfaces) Emsley (1953) Le Grand and El Hage (1980) Emsley (1953) Radii of Curvature* Radii of Curvature Radii of Curvature Anterior cornea = 7.8 mm Anterior cornea = 7.8 mm Anterior cornea = 5.55 mm Posterior cornea = 6.5 mm Anterior lens = 10.0 mm Anterior lens = 10.2 mm Posterior lens = -6.0 mm Posterior lens = -6.0 mm * from Le Grand and El Hage Modified Eye Models • The refractive surfaces are aspherical. • The crystalline lens is slightly decentered with respect to the axis of the cornea. • The crystalline lens has different refractive index increasing toward its center. Cornea Crystalline lens Classical eye model Modified eye model Visual axis Lens axis Classical eye model Modified eye model Not widely used - poor predictors of retinal image quality, don’t account for aberrations of real eyes Spherical wavefront Aberrated wavefront Planar wavefront Perfect Eye Aberrated Eye Every eye has a different pattern of higher order aberrations Perfect eye MRB GY AG MAK (diffraction limit) Wave Aberration 5.7 mm pupil Pointspread Function Retinal Image 0.5 deg Williams, Yoon, Guirao, Hofer, Porter, Cus.
    [Show full text]
  • Higher-Order Aberrations in Keratoconus
    Higher-Order Aberrations in Keratoconus A thesis submitted to The University of Manchester, for the degree of Doctor of Philosophy, in the Faculty of Life Sciences. 2012 Amit Jinabhai Optometry Thesis contents List of Figures ............................................................................................................................................... 4 List of Tables ................................................................................................................................................ 5 List of Equations ........................................................................................................................................... 6 Abbreviations list .......................................................................................................................................... 7 Abstract ......................................................................................................................................................... 8 Declaration .................................................................................................................................................... 9 Thesis Format ............................................................................................................................................... 9 Copyright statement ................................................................................................................................... 10 Acknowledgements ...................................................................................................................................
    [Show full text]
  • Wavefront Aberrations in Eyes with Acrysof Monofocal Intraocular Lenses
    Wavefront Aberrations in Eyes With Acrysof Monofocal Intraocular Lenses Prema Padmanabhan, MS; Geunyoung Yoon, PhD; Jason Porter, PhD; Srinivas K. Rao, FRCSEd; Roy J, MSc; Mitalee Choudhury, BS ABSTRACT hacoemulsifi cation, with the implantation of a fold- able intraocular lens (IOL), has become the most 1 PURPOSE: To characterize and measure the ocular ab- P popular technique for cataract surgery. The small errations in eyes implanted with monofocal intraocular self-sealing incision has reduced surgically induced astig- lenses (IOLs) and to study any correlation between post- matism.2 The continuous curvilinear capsulorrhexis has in- operative aberrations and surgical factors. creased the surgeon’s ability to ensure a stable centration of the IOL. Precision in biometry and improvements in calcula- METHODS: A Tscherning aberroscope was used to mea- tion of IOL power have enhanced the predictability of desired sure the wavefront aberrations of 62 eyes that had un- dergone phacoemulsifi cation with the implantation of postoperative results. All of these optical and biomechanical foldable monofocal Acrysof MA60BM IOLs (Alcon Labora- factors are responsible for the qualifi cation of cataract surgery tories Inc, Ft Worth, Tex). The Zernike coeffi cients, mea- as a “refractive procedure.” sured with a pupil diameter of 6 mm, were compared Until recently, the term “refractive procedure” has been with those of a normal dataset of 82 eyes of healthy used solely for spherocylindrical corrections. We now know young myopes. that optical imperfections other than spherocylindrical re- 3-5 0 fractive errors infl uence visual function. The introduction RESULTS: Spherical aberration (Z4) was the most pre- dominant higher order aberration, with a mean value of wavefront sensors into clinical practice has given the cli- of 0.37Ϯ0.16 µm.
    [Show full text]
  • Refractive Surgery: Today and the Future RAYMOND STEIN , MD, FRCSC, and REBECCA STEIN , BS C, MBC HB
    Volume XX, Issue X AS PRESENTED IN THE ® ROUNDS OF THE DEPARTMENT OF OPHTHALMOLOGY Ophthalm ology AND VISION SCIENCES, ROUNDS FACULTY OF MEDICINE, UNIVERSITY OF TORONTO Refractive Surgery: Today and the Future RAYMOND STEIN , MD, FRCSC, AND REBECCA STEIN , BS C, MBC HB Technologies and techniques continue to evolve in the correction of myopia, hyperopia, astigmatism, and presbyopia. Patients are increasingly interested in spectacle or contact lens independence. Clinicians need to understand today’s options for vision correction. This issue of Ophthalmology Rounds provides an overview of this exciting area of clinical advancements and research. With every surgical innovation, it is important to critically evaluate the outcomes and safety Department of Ophthalmology with long-term data. We need to be cautious with any new technology, as many refractive proce - and Vision Sciences Sherif El-Defrawy, MD dures have been abandoned due to lack of efficacy or late complications (Table 1). Professor and Chair Patients typically have high expectations with the available technology. They want their post - Jeffrey J. Hurwitz, MD operative uncorrected visual acuity (UCVA) to be equal or greater to their preoperative best-spec - Editor, Ophthalmology Rounds tacle corrected VA (BCVA). The role of the clinician is to evaluate the patient and the ocular health Valerie Wallace, PhD to determine if they are good candidates for any refractive procedure. Preoperative findings will Director of Research guide the surgeon in recommending specific refractive options (Table 2). To determine the preferred The Hospital for Sick Children surgical option, we can differentiate higher-order aberrations of the cornea versus the lens. Agnes Wong, MD Advanced wavefront units allow measurement of total higher-order aberrations of the eye, which Ophthalmologist-in-Chief can be differentiated in to those from the cornea versus the lens.
    [Show full text]
  • Ametropic Eye Modeling
    University of Tennessee, Knoxville TRACE: Tennessee Research and Creative Exchange Masters Theses Graduate School 5-2005 Ametropic Eye Modeling Bo Tan University of Tennessee - Knoxville Follow this and additional works at: https://trace.tennessee.edu/utk_gradthes Part of the Physics Commons Recommended Citation Tan, Bo, "Ametropic Eye Modeling. " Master's Thesis, University of Tennessee, 2005. https://trace.tennessee.edu/utk_gradthes/2363 This Thesis is brought to you for free and open access by the Graduate School at TRACE: Tennessee Research and Creative Exchange. It has been accepted for inclusion in Masters Theses by an authorized administrator of TRACE: Tennessee Research and Creative Exchange. For more information, please contact [email protected]. To the Graduate Council: I am submitting herewith a thesis written by Bo Tan entitled "Ametropic Eye Modeling." I have examined the final electronic copy of this thesis for form and content and recommend that it be accepted in partial fulfillment of the equirr ements for the degree of Master of Science, with a major in Physics. Ying-Ling Chen, Major Professor We have read this thesis and recommend its acceptance: James W.L. Lewis, Horace W. Crater Accepted for the Council: Carolyn R. Hodges Vice Provost and Dean of the Graduate School (Original signatures are on file with official studentecor r ds.) To the Graduate Council: I am submitting herewith a thesis written by Bo Tan entitled “Ametropic eye modeling.” I have examined the final electronic copy of this thesis for form and content and recommend that it be accepted in partial fulfillment of requirements for the degree of Master of Science, with a major in Physics.
    [Show full text]