Cisco MDS 9000 Family Troubleshooting Guide, Release 3.X Cisco MDS SAN-OS for Release 3.0(1)

Total Page:16

File Type:pdf, Size:1020Kb

Cisco MDS 9000 Family Troubleshooting Guide, Release 3.X Cisco MDS SAN-OS for Release 3.0(1) Send documentation comments to [email protected] Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x Cisco MDS SAN-OS for Release 3.0(1) April 2006 Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 Text Part Number: OL-9285-01 Send documentation comments to [email protected] THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS. THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY. The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California. NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. CCSP, CCVP, the Cisco Square Bridge logo, Follow Me Browsing, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries. All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0601R) Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental. Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x © 2002–2006 Cisco Systems, Inc. All rights reserved. Send documentation comments to [email protected] CONTENTS New and Changed Information xxiii Preface xxv Document Organization xxv Document Conventions xxvi Related Documentation xxviii Release Notes xxviii Compatibility Information xxviii Regulatory Compliance and Safety Information xxviii Hardware Installation xxviii Cisco Fabric Manager xxix Command-Line Interface xxix Troubleshooting and Reference xxix Installation and Configuration Note xxix Obtaining Documentation xxix Cisco.com xxx Product Documentation DVD xxx Ordering Documentation xxx Documentation Feedback xxx Cisco Product Security Overview xxxi Reporting Security Problems in Cisco Products xxxi Obtaining Technical Assistance xxxii Cisco Technical Support & Documentation Website xxxii Submitting a Service Request xxxii Definitions of Service Request Severity xxxiii Obtaining Additional Publications and Information xxxiii CHAPTER 1 Troubleshooting Overview 1-1 Overview of the Troubleshooting Process 1-1 Overview of Best Practices 1-2 Troubleshooting Basics 1-2 Troubleshooting Guidelines 1-2 Gathering Information Using Common Fabric Manager Tools and CLI Commands 1-3 Common Fabric Manager Tools 1-3 Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x OL-9285-01 iii Contents Send documentation comments to [email protected] Common CLI Commands 1-4 Verifying Basic Connectivity 1-4 Verifying SAN Element Registration 1-5 Fibre Channel End-to-End Connectivity 1-5 Fabric Issues 1-5 Port Issues 1-6 Primary Troubleshooting Flowchart 1-8 Overview of Symptoms 1-8 System Messages 1-9 System Message Text 1-9 Syslog Server Implementation 1-10 Implementing Syslog with Fabric Manager 1-10 Implementing Syslog with the CLI 1-11 Troubleshooting with Logs 1-12 Viewing Logs with Fabric Manager 1-12 Viewing Logs with the CLI 1-13 Viewing the Log from the Supervisor 1-13 Viewing NVRAM logs 1-13 Contacting Customer Support 1-14 CHAPTER 2 Troubleshooting Installs, Upgrades, and Reboots 2-1 Overview 2-1 Best Practices 2-2 Best Practices for Installations 2-2 Best Practices for Upgrading 2-2 Best Practices for Reboots 2-4 Disruptive Module Upgrades 2-4 Troubleshooting Fabric Manager Installations 2-4 Verifying Cisco SAN-OS Software Installations 2-5 Troubleshooting Cisco SAN-OS Software Upgrades and Downgrades 2-6 Software Installation Reports an Incompatibility 2-6 Diagnosing Compatibility Issues 2-6 Software Installation Ends with Error 2-8 Installing SAN-OS Software Using Fabric Manager 2-9 Installing Cisco SAN-OS Software from the CLI 2-10 Troubleshooting Cisco SAN-OS Software System Reboots 2-12 Power On or Switch Reboot Hangs 2-12 Corrupted Bootflash Recovery 2-13 Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x iv OL-9285-01 Contents Send documentation comments to [email protected] Recovery Using BIOS Setup 2-15 Recovery from the loader> Prompt 2-18 Recovery from the switch(boot)# Prompt 2-19 Recovery for Switches with Dual Supervisor Modules 2-20 Recovering One Supervisor Module With Corrupted Bootflash 2-20 Recovering Both Supervisor Modules With Corrupted Bootflash 2-21 Recognizing Error States 2-22 Switch or Process Resets 2-23 Recoverable System Restarts 2-24 Unrecoverable System Restarts 2-28 Recovering the Administrator Password 2-29 Miscellaneous Software Image Issues 2-29 All Ports Down Because of System Health Failure 2-29 Switch Reboots after FCIP Reload 2-30 FCIP Link Fails to Come Up 2-30 Cannot Create, Modify, or Delete Admin Role 2-30 FC IDs Change after Link Reset 2-31 Switch Displays Wrong User 2-31 CHAPTER 3 Managing Storage Services Modules 3-1 SSM Overview 3-1 Best Practices 3-3 Licensing Requirements 3-3 Initial Troubleshooting Checklist 3-3 Common Troubleshooting Tools in Fabric Manager 3-3 Common Troubleshooting Commands in the CLI 3-4 SSM Issues 3-4 SSM Fails to Boot 3-4 Upgrading the SSI Image 3-5 Verifying the SSI Boot Image 3-5 Using the install ssi Command 3-7 Recovering a Replacement SSM 3-9 SSM Upgrade Is Disruptive 3-9 Installing EPLD Images on Modules 3-10 CHAPTER 4 Troubleshooting Hardware 4-1 Overview 4-1 Best Practices 4-2 Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x OL-9285-01 v Contents Send documentation comments to [email protected] Best Practices for Switch Installation 4-2 Best Practices for System Initialization 4-2 Best Practices for Supervisor Modules 4-3 Troubleshooting Startup Issues 4-3 Troubleshooting Power Supply Issues 4-4 All Power Supply LEDS Are Off 4-5 Power Supply Input Ok LED is Red 4-6 Power Supply Output Failed LED is On 4-7 Power Supply Fan Ok LED is Red 4-7 Troubleshooting the Power Supplies 4-8 Troubleshooting Fan Issues 4-9 Fan Is Not Spinning 4-9 Fan Is Spinning; Fan LED is Red 4-9 Troubleshooting a Fan Failure Using Device Manager 4-10 Troubleshooting a Fan Failure Using the CLI 4-11 Temperature Threshold Violations 4-12 Troubleshooting Clock Module Issues 4-13 Troubleshooting Other Hardware Issues 4-14 Troubleshooting Supervisor Issues 4-15 Active Supervisor Reboots 4-16 Standby Supervisor Not Recognized by Active Supervisor 4-18 Verifying That a Standby Supervisor Failed to Synchronize Using the CLI 4-18 Standby Supervisor Stays in Powered-Up State 4-20 Verifying That a Standby Supervisor Is in the Powered-Up State Using Device Manager 4-21 Verifying That a Standby Supervisor Is in Powered-Up State Using the CLI 4-21 Troubleshooting Supervisor Modules 4-21 Troubleshooting Switching and Services Modules 4-22 Overview of Module Status 4-22 Module Initialization Overview 4-23 Module Bootup 4-24 Image Download 4-24 Runtime Diagnostics 4-25 Runtime Configuration 4-25 Online and Operational 4-25 Analyzing The Logs 4-26 Troubleshooting Module Issues 4-26 Troubleshooting Powered-Down Modules 4-27 Diagnosing a Powered-Down Module 4-29 Troubleshooting Reloaded Modules 4-32 Cisco MDS 9000 Family Troubleshooting
Recommended publications
  • IBM Storage Networking SAN768C-6 Product Guide
    Front cover IBM Storage Networking SAN768C-6 Product Guide Product Guide IBM Storage Networking SAN768C-6 Product Guide This IBM® Redbooks® Product Guide describes the IBM Storage Networking SAN768C-6. IBM Storage Networking SAN768C-6 has the industry’s highest port density for a storage area network (SAN) director and features 768 line-rate 32 gigabits per second (Gbps) or 16 Gbps Fibre Channel ports. Designed to support multiprotocol workloads, IBM Storage Networking SAN768C-6 enables SAN consolidation and collapsed-core solutions for large enterprises, which reduces the number of managed switches and leads to easy-to-manage deployments.1 By reducing the number of front-panel ports that are used on inter-switch links (ISLs), it also offers room for future growth. IBM Storage Networking SAN768C-6 addresses the mounting storage requirements of today’s large virtualized data centers. As a director-class SAN switch, IBM Storage Networking SAN768C-6 uses the same operating system and management interface as other IBM Storage Networking c-type data center switches and directors. It brings intelligent capabilities to a high-performance, protocol-independent switch fabric, and delivers uncompromising availability, security, scalability, simplified management, and the flexibility to integrate new technologies. You can use IBM Storage Networking SAN768C-6 to transparently deploy unified fabrics with Fibre Channel connectivity to achieve low total cost of ownership (TCO). For mission-critical enterprise storage networks that require secure, robust, cost-effective business-continuance services, the FCIP extension module is designed to deliver outstanding SAN extension performance, reducing latency for disk and tape operations with FCIP acceleration features, including FCIP write acceleration and FCIP tape write and read acceleration.
    [Show full text]
  • Storage Area Network (SAN) Security and Performance
    MASTER THESIS Evaluation of Storage Area Network (SAN) Security and Performance Master Thesis in Computer Network Engineering November 2013 Author: Siavash Hajirostam Supervisor: Tony Larsson Examiner: Tony Larsson __________________________________ School of Information Science, Computer and Electrical Engineering Halmstad University PO Box 823, SE-301 18 HALMSTAD Sweden Evaluation of Storage Area Network (SAN) Security and Performance Siavash Hajirostam © Copyright Siavash Hajirostam, 2013. All rights reserved. Master thesis report IDE 1325 School of Information Science, Computer and Electrical Engineering Halmstad University Preface I would like to express my appreciation to my supervisor, Professor Tony Larsson, for the many useful discussions, comments and suggestions on this thesis and also my thanks go to the staff of Halmstad University for giving me the opportunity to study in the computer network engineering program. Finally, my special thanks to my family for their encouragement and support during my stud ies. Siavash Hajirostam Halmstad, November 2013 i Abstract Due to growing the number of Information Technology (IT) users all around the world, consequently the amount of data that needs to be stored is increasing day by day. Single attached disks and old storage technologies cannot manage the storing these amounts of data. Storage Area Network (SAN) is a distributed storage technology to manage the data from several nodes in centralize place and secure. This thesis investigates how SAN works, the file system and protocols that are used in implementation of SAN. The thesis also investigate about other storages technologies such as Network Attached Storage (NAS) and Direct Attached Storage (DAS) to figure out the advantages and disadvantages of SAN , The main focus of the thesis project is on identifying the security vulnerabilities in SAN such as possible attacks in different SAN protocols.
    [Show full text]
  • HPE Storefabric SN6500C 16Gb FC/FCIP/Fcoe Multi-Service Switch
    QuickSpecs HPE StoreFabric SN6500C Multi-service Switch Overview HPE StoreFabric SN6500C Multi-service Switch HPE SN6500C 16Gb Multi-service Switch (MDS 9250i) HPE StoreFabric SN6500C 16Gb FC/FCIP/FCoE Multi-service Switch (MDS9250i) The HPE StoreFabric SN6500C 16Gb Multi-service Switch (MDS 9250i) brings the most flexible storage networking capability available in the fabric switch market today. Sharing a consistent architecture with the MDS 9700 (SN8500C) Directors, The HPE SN6500C 16Gb Multi-service Switch integrates both Fibre Channel and IP Storage Services in a single system to allow maximum flexibility in user configurations. With 20 16-Gbps Fibre Channel ports active by default, two 10 Gigabit Ethernet IP Storage Services ports, and 8 10 Gigabit Ethernet FCoE ports, the SN6500C 16Gb Multi-service switch is a comprehensive package, ideally suited for enterprise storage networks that require high performance SAN extension or cost-effective IP Storage connectivity for applications such as Business Continuity using Fibre Channel over IP or iSCSI host attachment to Fibre Channel storage devices. Also, using the eight 10 Gigabit Ethernet FCoE ports, the SN6500C 16Gb Multi-service Switch attaches to directly connected FCoE and Fibre Channel storage devices and supports multi-tiered unified network fabric connectivity directly over FCoE. HPE SN6500C 16Gb Multi-service Switch Page 1 QuickSpecs HPE StoreFabric SN6500C Multi-service Switch Overview Key Features and Benefits Please note that some features require the optional HPE SN6500C Enterprise Package license to be activated • Integrated Fibre Channel and IP Storage Services in a single optimized form factor: - Supports up to forty 16-Gbps Fibre Channel interfaces for high performance storage area network (SAN) connectivity plus two 10 Gigabit Ethernet ports for Fibre Channel over IP (FCIP) and Small Computer System Interface over IP (iSCSI) storage services plus eight 10 Gigabit Ethernet FCoE ports.
    [Show full text]
  • Mac OS X Fibre Channel Connectivity to the HP Storageworks Enterprise Virtual Array Storage System Configuration Guide
    Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-0025 Third edition: July 2009 Legal and notice information © Copyright 2007, 2009 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Intel is a trademark of Intel Corporation or its subsidiaries in the U.S. and other countries. Apple and the Apple logo are trademarks of Apple Computer, Inc., registered in the U.S. and other countries. Java is a US trademark of Sun Microsystems, Inc. Contents About this guide ................................................................................... 7 Intended audience ...................................................................................................................... 7 Related documentation ...............................................................................................................
    [Show full text]
  • Exam : 350-040 Title : Storage Networking Ver : 10-02-07
    Exam : 350-040 Title : Storage Networking Ver : 10-02-07 350-040 QUESTION 1: Which statements are true about a cascaded FICON topology? Select three. A. It requires Fabric binding to be configured in all the switches. B. Only one hope (ie:traversing 2 switchs) is supported. C. Separate ISLs must be used dedicated to FICON traffic. D. Two byte link addressing as defined in FC-SB2, is mandatory. Answer: A, B, D QUESTION 2: MDS3 _ 9509# install all system bootflash:m9500-sf1 ek9-mz.1.3.4.bin kickstart bootflash:m9500-sfek9-kickstart-mz.1.3.4.bin Verifying image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Verifying image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Extracting "sic"version from image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Extracting "ips" version from image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Extracting "system" version from image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Extracting "kickstart"version from image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Extracting "loader" version from image bootflash:/m9500-sf1ek9kickstart-mz.1.3.4.bin [####################] 100% -- SUCCESS Compatibility check is done: Module bootable impact install-type reason --------- --------- ---------- ------- ----- --------- 2 yes non-disruptive rolling 3 yes disruptive rolling Hitless upgrade
    [Show full text]
  • Dell Compellent Storage Center Switch Connectivity Best Practices
    Dell Compellent Storage Center Switch Connectivity Best Practices Dell Compellent Storage Center Switch Connectivity Best Practices Page 2 Dell Compellent Storage Center Switch Connectivity Best Practices Document revision Date Revision Comments Author 8/10/09 A Initial Release BR THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. © 2011 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell. Dell, the DELL logo, the DELL badge, and Compellent are trademarks of Dell Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. Page 3 Dell Compellent Storage Center Switch Connectivity Best Practices Contents Document revision ............................................................................................... 3 Contents ............................................................................................................... 4 General syntax ................................................................................................... 6 Conventions ......................................................................................................
    [Show full text]
  • Cisco MDS 9000 Family 8-Gbps Fibre Channel Switching Modules
    Data Sheet Cisco MDS 9000 Family 8-Gbps Fibre Channel Switching Modules Cisco ® MDS 9000 Family 8-Gbps Fibre Channel switching modules deliver the intelligence and the high performance required to support the most demanding storage applications, providing the foundation for large scale Storage Area Network (SAN) consolidation. Delivering up to 528 8-Gbps ports per chassis and twice the bandwidth of previous switching modules, the 8-Gbps Fibre Channel switching modules enable you to build consolidated SANs with fewer chassis for dramatic savings in space, power and cooling, and total cost of ownership (TCO). Cisco MDS 9000 Family 8-Gbps Fibre Channel switching modules are available in three configurations: ● The 24-Port 8-Gbps Fibre Channel Switching Module delivers the highest performance for high-end storage subsystems and for Inter Switch Link (ISL) connectivity. ● The 48-Port 8-Gbps Fibre Channel Switching Module provides optimized performance and port density for connection of high-performance and virtualized servers. ● The 4/44-Port 8-Gbps Host-Optimized Fibre Channel Switching Module offers a very cost-effective solution for consolidating standard servers into the smallest number of SAN switches, in many cases eliminating the need for core-edge topologies. The 8-Gbps Fibre Channel switching modules are compatible with all MDS 9500 Series Multilayer Directors, enabling you to continue to use your existing 2- and 4-Gbps MDS 9000 Family Fibre Channel switching modules and gradually phase in 8-Gbps technology as your network demands it. Product Overview 24-Port 8-Gbps Fibre Channel Switching Module For the most demanding storage networking environments, the Cisco MDS 9000 Family 24-Port 8-Gbps Fibre Channel Switching Module delivers uncompromising performance.
    [Show full text]
  • Demartek Fibre Channel Deployment Guide 2014
    June 2014 Demartek 16Gb Fibre Channel Deployment Guide Overview The current generation of Fibre Channel (FC), which is 16Gb Fibre Channel (16GFC), was first introduced in the second half of calendar year 2011, and the industry is beginning to see increased interest and adoption of 16Gb Fibre Channel. Therefore, Demartek has produced this Demartek Fibre Channel Deployment Guide, one in a series of technology deployment guides. This guide can be found on our website in our FC Zone or by searching the Internet for “Demartek Fibre Channel Deployment Guide” using any well- known Internet search engine. Audience This guide is designed for managers and technical professionals within IT departments who are exploring the benefits of deploying, or upgrading to, Fibre Channel technology in general, or 16Gb Fibre Channel specifically, or who are looking for actual deployment examples of 16Gb Fibre Channel solutions. Objectives of this Guide This guide is designed to provide basic information about 16Gb Fibre Channel and practical guidance for planning and deploying 16Gb Fibre Channel technology and products. The focus is 16Gb Fibre Channel in primarily, but not exclusively, virtualized environments. Because 16Gb Fibre Channel includes server adapter and switching technologies, this guide provides information and guidance in each area. A basic understanding of each of these areas is needed to successfully deploy 16Gb Fibre Channel technology. This guide is intended to be used as a reference and is divided into sections including marketplace data, technology areas, and deployment guidance for virtual servers. There are screen shots and information from actual deployments of some products. At the time of the testing conducted for this guide, there were few true 16Gb Fibre Channel storage targets.
    [Show full text]
  • We're Ready. Are You?
    We’re ready. Are you? FCoE for Small and Mid-size Enterprise Hernan Vukovic Consulting Systems Engineer BRKSAN-2101 The Session Objectives: • Provide a refresh of FCoE and DCBX • Understand the basic FCoE implementation on Nexus 5K • FCoE design options for small and mid-size enterprise • FCoE deployment with Cisco Unified architecture • Step-by-step configuration examples The Session Non-Objectives: • Nexus hardware architecture deep dive • UCS storage architecture • SAN distance extension using FCoE • FCOE or iSCSI, who is better for small and mid-size customers Related Sessions Storage Contents • BRKCOM-2007 - UCS Storage Integration, Technologies, and Topologies Traditional Data Center Design Ethernet LAN and Fibre Channel SAN Ethernet FC FC Fabric ‘A’ Fabric ‘B’ L3 L2 LAN NIC HBA SAN Agenda • Introduction to FCoE Technology • FCoE SAN Design for Small and Mid-size Enterprise • Basic FCoE Configuration and Troubleshooting • Conclusion Agenda • Introduction to FCoE Technology • FCoE SAN Design for Small and Mid-size Enterprise • Basic FCoE Configuration and Troubleshooting • Conclusion Block Storage Protocols (FC/FCoE/iSCSI) What is SAN (Storage Area Network) LAN (TCP/IP) SAN (Fibre Channel, iSCSI, FCoE) A dedicated network that provides access to consolidated, block level data storage. The SCSI I/O Transaction • The SCSI protocol defines a bus based system used to carry block based storage commands • The channel provides connectivity between server and storage The following shows two sample SCSI exchanges: Host (Initiator) Disk (Target)
    [Show full text]
  • Data Centre Bridging and Fcoe Implementation
    Arsalan Iqbal, Sameer Liaqat Ali Khan, Rafi Qureshi & Shair Akbar Khan Unified Fabric: Data Centre Bridging and FCoE Implementation Arsalan Iqbal [email protected] Infrastructure Support Technologist Georgian College Barrie, L4M3X9, Canada Sameer Liaqat Ali Khan [email protected] M.Eng Computer Networks Ryerson University Toronto, M5B2K3, Canada Rafi Qureshi [email protected] M.Eng Computer Networks Ryerson University Toronto, M5B2K3, Canada Shair Akbar Khan [email protected] IT Infrastructure Administrator NFF/CTG Brampton, L6T 4K3, Canada Abstract In the past decade cloud computing has become the buzzword in IT world. The implementation of cloud based computing and storage technology changed the way of how network infrastructure is built inside an enterprise. As technology has improved and the cloud based storage systems become more affordable, a number of enterprises started outsourcing their data management due to a number of reasons. But still a majority of large enterprises and SMB (small medium businesses) prefer to manage their own in-house data centers and storage area networks. The reason being is the control, security and integrity of stored data on cloud storage servers. In this paper, we will discuss the most commonly implemented SAN technology, fibre channel (FC) in comparison with the new technology called Fibre Channel over Ethernet (FCoE). These results will help SAN engineers and designers select the best technology between the two in terms of performance, scalability, cost, maintenance, space, cooling, equipment, cabling, management, adapters, labor cost and manpower. Implementation of FC and FCoE has been done to explore the different features of both technologies.
    [Show full text]
  • HPE C-Series SN6500C Multiservice Switch Overview
    QuickSpecs HPE C-series SN6500C Multiservice Switch Overview HPE C-series SN6500C Multiservice Switch HPE SN6500C 16Gb FC/FCIP/FCoE Multi-service Switch (MDS9250i) The HPE SN6500C 16Gb Multi-service Switch (MDS 9250i) brings the most flexible storage networking capability available in the fabric switch market today. Sharing a consistent architecture with the MDS 9700 (SN8500C) Directors, The HPE SN6500C 16Gb Multi-service Switch integrates both Fibre Channel and IP Storage Services in a single system to allow maximum flexibility in user configurations. With 20 16-Gbps Fibre Channel ports active by default, two 10 Gigabit Ethernet IP Storage Services ports, and 8 10 Gigabit Ethernet FCoE ports, the SN6500C 16Gb Multi-service switch is a comprehensive package, ideally suited for enterprise storage networks that require high performance SAN extension or cost-effective IP Storage connectivity for applications such as Business Continuity using Fibre Channel over IP or iSCSI host attachment to Fibre Channel storage devices. Also, using the eight 10 Gigabit Ethernet FCoE ports, the SN6500C 16Gb Multi-service Switch attaches to directly connected FCoE and Fibre Channel storage devices and supports multi-tiered unified network fabric connectivity directly over FCoE. HPE SN6500C 16Gb Multi-service Switch Page 1 QuickSpecs HPE C-series SN6500C Multiservice Switch Standard Features Key Features and Benefits Please note that some features require the optional HPE SN6500C Enterprise Package license to be activated • Integrated Fibre Channel and IP Storage Services in a single optimized form factor: − Supports up to forty 16-Gbps Fibre Channel interfaces for high performance storage area network (SAN) connectivity plus two 10 Gigabit Ethernet ports for Fibre Channel over IP (FCIP) and Small Computer System Interface over IP (iSCSI) storage services plus eight 10 Gigabit Ethernet FCoE ports.
    [Show full text]
  • Configuring Fibre Channel Zoning
    Configuring Fibre Channel Zoning This chapter includes the following sections: • Information About Fibre Channel Zoning, page 1 • Support for Fibre Channel Zoning in Cisco UCS Manager, page 2 • Guidelines and recommendations for Cisco UCS Manager-Based Fibre Channel Zoning, page 4 • Configuring Cisco UCS Manager Fibre Channel Zoning, page 4 • Creating a VSAN for Fibre Channel Zoning, page 5 • Configuring Fibre Channel Storage Connection Policies, page 8 Information About Fibre Channel Zoning Fibre Channel zoning allows you to partition the Fibre Channel fabric into one or more zones. Each zone defines the set of Fibre Channel initiators and Fibre Channel targets that can communicate with each other in a VSAN. Zoning also enables you to set up access control between hosts and storage devices or user groups. The access and data traffic control provided by zoning does the following: • Enhances SAN network security • Helps prevent data loss or corruption • Reduces performance issues Information About Zones A zone consists of multiple zone members and has the following characteristics: • Members in a zone can access each other; members in different zones cannot access each other. • Zones can vary in size. • Devices can belong to more than one zone. • A physical fabric can have a maximum of 8,000 zones. Cisco UCS Manager GUI Configuration Guide for Cisco UCS Mini, Release 3.0 1 Configuring Fibre Channel Zoning Information About Zone Sets Information About Zone Sets Each zone set consists of one or more zones. You can use zone sets to enforce access control within the Fibre Channel fabric. In addition, zone sets provide you with the following advantages: • Only one zone set can be active at any time.
    [Show full text]