SUMMARY Total Number of Structures = 696 Buildings = 506 = 166 Other = 24 Total Number of Dampers = 26,435

Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Taylor Viscous Dampers 2018 Seismic Viscous dampers to control excessive dynamic response of a National Theatre UK, London Total: 8 steel floor caused by pedestrian movement in a rooftop 10 kN ± 25mm stroke pavillon. Taylor Viscous Dampers 2018 Seismic Tuned mass dampers used to reduce vertical and horizontal Footbridge in front of Museu dos Coches Portugal, Libson Total: 34 movements caused by pedestrians crossing the new footbridge 2 kN ± 50mm stroke in front of the museum. TSMC FAB #18 P1 STSP Taiwan, Tainan Taylor Viscous Dampers 2018 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 48 dissipate seismic energy and reduce vibrations and micro- 2000 kN ± 75mm stroke vibrations from earthquakes. Huancayo Hospital Peru, Huancayo Taylor Viscous Dampers 2018 Seismic 2 new six story steel moment frame buildings use dampers in Total: 155 chevron and diagonal brace to dissipate seismic energy. This is 1000 kN ± 75mm stroke the first hospital project in Peru to use viscous dampers for 1200 kN ± 75mm stroke seismic protection. 1300 kN ± 75mm stroke 1500 kN ± 75mm stroke 1390 Market Street (Fox Plaza) USA, San Francisco, CA Taylor Viscous Dampers 2018 Seismic Voluntary seismic upgrade to a triangular shaped steel-frame Total: 28 building uses dampers in chevron frames for earthquake 1000 kN ± 100mm stroke energy dissipation.

The Foundation for Hispanic Education USA, San Jose, CA Taylor Viscous Dampers 2018 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 160 kN ± 75mm stroke TSMC FAB #15 P7 CTSP Taiwan, Taichung Taylor Viscous Dampers 2018 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 52 dissipate seismic energy and reduce vibrations from 2000 kN ± 75mm stroke earthquakes.

Tendril Sanchong SRC Taiwan Taylor Viscous Dampers 2018 Seismic New 27-story SC residentail project uses fluid viscous devices Total: 44 to dissipate seismic energy and reduce vibrations under 800kN ± 75mm stroke earthquakes.

Page 1 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Naxi River Four-Track Railway Taylor Viscous Dampers 2018 Seismic New railway bridge uses Lock-up to protect the structure Yunnan, China Total: 8 during earthquakes. 3500KN ±100mm stroke Jing Hong Bridge Taylor Viscous Dampers 2018 Seismic New railway bridge uses dampers to protect the structure Yunnan, China Total: 4 during earthquakes. 5500KN ±200mm stroke Ganlanba Bridge Taylor Viscous Dampers 2018 Seismic Total: 4 New railway bridge uses dampers to protect the structure Yunnan, China 5500KN ±250mm stroke during earthquakes. 2000KN ±250mm stroke St. Bernardine Medical Center USA, San Bernardino, CA Taylor Viscous Dampers 2018 Seismic Seismic upgrade of a 1972 six-story steel moment frame Total: 108 hospital. New moment frames were added to the exterior of 3400kN ± 225mm stroke the building to allow the hospital to remain functional during 1025kN +/-225mm stroke construction. Farglory H100 Taiwan, Xinbei City Taylor Viscous Dampers 2018 Seismic Dampers are used in new SC residential building to dissipate Total: 112 seismic energy. 1000kN ± 75mm stroke East Link Extension Bridge USA, Seattle, WA Taylor Viscous Dampers 2018 Seismic Seismic upgrade of a segmental concrete box Total: 8 that acts as the approach for the Homer Hadley Floating 2900kN ± 175mm stroke Bridge.

Farglory H98 Taiwan, Xinbei City Taylor Viscous Dampers 2018 Seismic Dampers are used in new SC residential building to dissipate Total: 68 seismic energy. 500kN ± 75mm stroke

Eto-Ohashi Bridge Japan, Miyazaki Taylor Viscous Dampers 2018 Seismic Dampers are installed on each side of the bridge and are used Prefecture Total: 9 to provide energy dissipation and reduce displacement due to 1000kN ± 480mm stroke earthquake motion. 200kN +/-700mm stroke

Dublin Scioto Pedestrian Bridge USA, Dublin, OH Taylor Viscous Dampers 2018 Pedestrian TMDs with Taylor Fluid Viscous Dampers are used to Total: 2 TMD Systems attenuate human-induced vibrations on this pedestrian and 4500 KG TMDs bicycle bridge connecting riverside crossing park with the residential and retail sections of downtown Dublin, OH.

Beijing Guanting Reservoir Bridge China Taylor Viscous Dampers 2018 Seismic Total: 4 New with a main span of 720m uses 3850kN ± 550mm stroke dampers to protect the structure during earthquakes.

Taylor Viscous Dampers Beijing Dongcheng District Children Reinforced concrete building uses dampers in chevron braces Beijing, China Total: 32 2017 Seismic 's Palace to dissipate seismic energy. 750KN ±75mm stroke

Page 2 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Defense Industry Company Turkey/Ankara Taylor Viscous Dampers 2017 Seismic Dampers are used in a vibration isolation experimental study Total: 4 where the dampers protect the system by providing energy 2kN ± 25mm stroke dissipation for overspeed impacts.

Oakland Tribune Building USA, Oakland, CA Taylor Viscous Dampers 2017 Seismic Voluntary seismic upgrade of twenty-two story concrete frame Total: 15 building originally constructed in 1906 and currently on the 1000kN ± 100mm stroke National Register of Historic Places. AU Optronics Ho-Li Building Taiwan Taylor Viscous Dampers 2017 Seismic TFT-LCD factory retrofit project using dampers to dissipate Total: 74 seismic energy. 1500kN ± 100mm stroke

Stadium in California USA, California Taylor Viscous Dampers 2017 Seismic Stadium uses lock-up dampers to protect stadium sections Total: 32 from earthquake vibrations. 6500kN ± 100mm stroke

Wind Turbine USA, Colorado Taylor Viscous Dampers 2017 Wind Trial application of fluid visous dampers for attenuation of Total: 3 micro-vibrations from wind input. 345kN ± 25mm stroke

Chinalife Taipei BOT Taiwan Taylor Viscous Dampers 2018 Seismic Dampers are used in this steel-structure office building to Total: 152 reduce vibrations caused by earthquakes. 750kN ± 100mm stroke

Zhejiang Xiushan Bridge China Taylor Viscous Dampers 2018 Seismic Total: 4 New Suspension bridge with a main span of 926m uses 1200KN ±270mm stroke dampers to protect the structure during earthquakes. 1200KN ±170mm stroke CHEM Dunhua South Road Taiwan Taylor Viscous Dampers 2017 Seismic This is an urban renewal project. Residentials buildings use Total: 60 dampers to dissipate seismic energy. 800kN ± 75mm stroke

Curtarolo Footbridge Italy Taylor Viscous Dampers 2017 Pedestrian Total: 12 9kN ± 75mm stroke

Ginza 5TH Street Project Japan, Tokyo Taylor Viscous Dampers 2018 Seismic Dampers are used to provide energy dissipation and reduce Total: 8 displacement due to earthquake motion. The dampers are 2000kN ± 40mm stroke installed in both vertical and diagonal directions. 2500kN ± 40mm stroke

Page 3 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information AU Optronics Long Tan Building Taiwan Taylor Viscous Dampers 2017 Seismic New TFT-LCD factory using dampers to dissipate seismic Total: 36 energy. 500kN ± 55mm stroke

Residence on North Orlando Avenue USA, Los Angeles, CA Taylor Viscous Dampers 2017 Seismic Single family residence Total: 25 135kN ± 75mm stroke

Guayaquil Bridge Ecuador Taylor Viscous Dampers 2017 Seismic Seismic upgrade of a steel girder highway bridge. Total: 4 400kN ± 250mm stroke

Beverly Hills Post Office USA, Beverly Hills, CA Taylor Viscous Dampers 2017 Seismic Total: 13 2000kN ± 125mm stroke 3000kN +/-100mm stroke Rayito Del Sol Pedestrain Bridge Peru, Lima Taylor Viscous Dampers 2017 Seismic Retrofit of a pedestrian bridge. Total: 1 1350kN ± 100mm stroke

Shin Kong Life Insurance Building Taiwan, Taipei Taylor Viscous Dampers 2017 Seismic New SRC residential building uses viscous dampers to Total: 108 dissipate seismic energy. 1000kN ± 60mm stroke

Cristo Rey School USA, San Jose, CA Taylor Viscous Dampers 2017 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 160 kN ± 75mm stroke

Anhui Yinshang Bridge China Taylor Viscous Dampers 2017 Seismic New Dwarf tower cable-stayed bridge with a main span of Total: 8 220m uses dampers to protect the structure during 3500 kN ± 250mm stroke earthquakes. 217 West 57th Street USA, New York, NY Taylor Viscous Dampers 2017 Wind New structure uses Taylor Viscous Dampers as part of a 1102 Total: 12 ton Tuned Mass Damping (TMD) system at the top of the 310kN ± 813mm stroke building to improve occupant comfort during wind storms. 160kN ± 915mm stroke

Clementina Tower USA, San Francisco, CA Taylor Viscous Dampers 2017 Seismic Dampers used to control movement of a large canopy. Total: 4 45kN ± 75mm stroke

Page 4 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Shengxing Nangung Taiwan, Xinbei City Taylor Viscous Dampers 2017 Seismic New residential building uses dampers to reduce deflection Total: 8 and provide energy dissipation. 490kN ± 75mm stroke

Farglory H103 Taiwan, Xinbei City Taylor Viscous Dampers 2017 Seismic New RC residential building uses viscous dampers to dissipate Total: 6 seismic energy. 490kN ± 75mm stroke

Farglory H101A Taiwan, Xinbei City Taylor Viscous Dampers 2017 Seismic New SRC residential building uses viscous dampers to Total: 20 dissipate seismic energy. 490kN ± 75mm stroke

CHCH Outpatient Building New Zealand, Christchurch Taylor Viscous Dampers 2017 Seismic New construction of a 5 story steel frame medical building Total: 54 uses dampers in diagonal braces to protect from earthquakes. 500kN ± 100mm stroke 750kN ± 100mm stroke 1000kN ± 100mm stroke Naval Medical Center San Diego Phase 2 USA, San Diego, CA Taylor Viscous Dampers 2017 Seismic Retrofit of steel moment frame structure uses dampers in Total: 36 diagonal bracing elements to dissipate seismic energy. 735kN ± 100mm stroke

Robert A. Young (RAY) Building USA, St. Louis, MO Taylor Viscous Dampers 2017 Seismic Seismic strengthening of a 20 story Federal building. Dampers Total: 385 range from 100 to 330 kip, +/- 1.0 stroke. 1470kN ± 100mm stroke

St. Jude Hospital Data Center USA, Memphis, TN Taylor Viscous Dampers 2017 Seismic New construction of a computer-server data center uses Total: 30 dampers in diagonal braces to protect from earthquakes from 735kN ± 100mm stroke the nearby New Madrid fault line 980kN ± 100mm stroke 1470kN ± 100mm stroke 3540 Wilshire Boulevard USA, Los Angeles, CA Taylor Viscous Dampers 2017 Seismic 13 story building near Koreatown in Los Angeles. Total: 52 735kN ± 100mm stroke 980kN ± 100mm stroke

Page 5 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Ichilov Medical Center Israel Taylor Viscous Dampers 2017 Seismic Seismic protection for an existing hospital complex of 3 Total: 64 adjacent buildings, with independent structure strengthening 1000kN ± 100mm stroke and connecting them with each other for better earthquake deflection.

Raffles City Chongqing China, Chongqing Taylor Viscous Dampers 2017 Seismic New construction, large-span corridor between the building Total: 16 set dampers for seismic 3100kN ± 350mm stroke 3200kN ± 450mm stroke

San Miguel Mall Peru Taylor Viscous Dampers 2017 Seismic Total: 54 880kN ± 75mm stroke

Kansai University Remodel Japan Taylor Viscous Dampers 2016 Seismic Dampers used to provide energy dissipation and reduce Total: 8 displacement due to earthquake motion. These dampers are 500kN ± 100mm horizontally installed between the new constructed building 500kN ± 120mm and the old building.

New Udaan Bhawan, Corporate HQ India, New Delhi Taylor Viscous Dampers 2017 Seismic Existing reinforce concrete, Corporate HQ office building has Building at Delhi International Airport Total: 84 been upgraded to Immediate Occupancy performance 750 kN ± 100mm stroke standard using Non-Linear fluid viscous dampers. All dampers have been installed on the periphery of the building and have been kept visible. The work was completed while the building was fully operational.

Sunat Arenales Building Peru Taylor Viscous Dampers 2016 Seismic Total: 24 1300kN ± 100 mm stroke

TSMC #15, P6 Taiwan, Taichug Taylor Viscous Dampers 2016 Seismic New semiconductor fabrication plant uses dampers to Total: 52 dissipate seismic energy and reduce acceleration reponse. 2000kN ± 75mm stroke

Page 6 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Vincent Thomas Bridge USA, San Pedro, CA Taylor Viscous Dampers 2017 Seismic Retrofit project for a 1963 suspension bridge with 1500 ft Total: 40 main span uses Taylor dampers for earthquake energy 734 kN ± 610mm stroke dissipation. 334 kN ± 560mm stroke 1160 kN ± 660mm stroke T-Tower Building Peru Taylor Viscous Dampers 2016 Seismic Total: 22 600kN ± 55mm stroke

Bremerton Kitsap Building 431 USA, Bremerton, WA Taylor Viscous Dampers 2016 Seismic Fluid lock-up devices placed across roof thermal joints to Total: 81 create a uniform load path during earthquake. 245kN ± 75mm stroke 490kN ± 100mm stroke 734kN ± 100mm stroke 980kN ± 100mm stroke 1468kN ± 100mm stroke 1960kN ± 125mm stroke Guatemala University Guatemala Taylor Viscous Dampers 2016 Seismic Total: 64 736/883kN ± 75mm stroke

Cedar City Temple USA, Washington, UT Taylor Viscous Dampers 2016 Seismic Total: 4 490kN ± 75mm stroke

Nova Academy USA, Santa Ana, CA Taylor Viscous Dampers 2016 Seismic Four story steel moment frame in Anaheim upgrade for Total: 35 conversion from offices to a school. 890kN ± 100mm stroke

Soma Towers USA, Bellevue, WA Taylor Viscous Dampers 2016 Seismic/Wind Total: 4 5kN ± 75mm stroke

Page 7 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Farglory H110 Taiwan, Xinbei City Taylor Viscous Dampers 2016 Seismic Dampers are used in new SC residential building to dissipate Total: 136 seismic energy. 490kN ± 75mm stroke

Farglory H132 Taiwan, Xinbei City Taylor Viscous Dampers 2016 Seismic Dampers are used in new SC residential building to dissipate Total: 12 seismic energy. 490kN ± 75mm stroke

Oscar Nanjing Building Taiwan, Taipei Taylor Viscous Dampers 2016 Seismic Dampers are used in new SC residential building to dissipate Total: 124 seismic energy. 490kN ± 75mm stroke

Farglory O1 Taiwan, Kaohsiung Taylor Viscous Dampers 2016 Seismic/Wind Dampers are installed in new 65-story SS residential building Total: 164 to dissipate seismic and wind energy. 980kN ± 75mm stroke

NAC Nuclear Crane Taiwan Taylor Viscous Dampers 2016 Seismic Seismic damping used in cross bracing for a nuclear crane. Total: 8 500 kN ± 75mm stroke

LaSalle Bridge Canada, Kingston, Ontario Taylor Viscous Dampers 2016 Bridge Hydraulic energy absorption for protection from overspeed Total: 2 Movement impacts. 378kN, 355 mm

Adolphe Bridge Luxembourg Taylor Viscous Dampers 2016 Bridge movement Lock-Up devices used to lock the deck movement when cars Total: 4 drive across the bridge. 40kN ± 50mm stroke

DongPing Waterway Bridge China Taylor Viscous Dampers 2016 Seismic New railway bridge, uses dampers to control longitudianl Total: 16 movement 1800kN ± 100mm stroke 2500kN ± 150mm stroke 3600kN ± 150mm stroke

Page 8 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information MW-FEP Industrial Building Italy, Genova Taylor Viscous Dampers 2016 Seismic Dampers used in chevron braces for earthquake protection of Total: 31 industrial building. 220 kN ± 75mm stroke 250 kN ± 75mm stroke

Fujisawa City Hall Japan, Fujisawa Taylor Viscous Dampers 2016 Seismic Dampers installed with a base isolation system to provide Total: 16 viscous damping, the dampers having a maximum input 1450kN ± 610mm velocity of 200cm/sec.

Uni-President Prince Worldvista Taiwan, Xinbei City Taylor Viscous Dampers 2016 Seismic New residential building uses dampers to reduce deflection Total: 40 and provide energy dissipation. 500 kN ± 75mm stroke

Berkeley Hills Residence USA, Berkeley, CA Taylor Viscous Dampers 2016 Seismic Residential wood-framed house uses dampers in steel frames Total: 2 to provide earthquake energy dissipation 90 kN ± 75mm stroke

Wittpenn Lift Bridge USA, Kearney, NJ Taylor Viscous Buffers 2016 Bridge Hydraulic energy absorption for protection of vertical lift Total: 4 Movement section from overspeed impacts, while providing soft landing 267 kN 150mm stroke for normal speed closures.

Unilev-Corlu Factory Turkey Taylor Viscous Dampers 2016 Seismic Dampers used to provide energy dissipation and reduce Total: 10 displacement due to earthquake motion for the retrofit of a 750 kN ± 100mm stroke food production plant. 500 kN ± 100mm stroke

LDS Temple Concepcion Chile, Concepcion Taylor Viscous Dampers 2016 Seismic Base isolated structure uses dampers at the level of the Total: 9 isolators to reduce displacement. 1112 kN ± 813mm stroke

Maid of the Mist USA, Niagara Falls, NY Taylor Viscous Buffers 2016 Boat Impact Buffers act as shock absorbers to prevent damage to floating Total: 2 dock/loading platform in the event of boat impact. 178 kN ± 229mm stroke

Page 9 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information New Gerald Desmond Bridge USA, Long Beach, CA Taylor Viscous Dampers 2016 Seismic New cable stayed bridge with a main span of 120m and a total Total: 34 length of 1565m uses fused dampers between the towers and 3930 kN ± 813mm stroke bridge deck to limit motion and dissipate seismic energy. 3930 kN ± 1016mm stroke 3470 kN ± 508mm stroke Deryunn JingDing Project Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic A residential project using viscous dampers to dissipate Total: 56 seismic energy. 500 kN ± 55mm stroke

Xinchuang Project Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic A residential project using viscous dampers to dissipate Total: 52 seismic energy. 500 kN ± 55mm stroke

Arch of Triumph Romania, Bucharest Taylor Viscous Dampers 2015 Seismic Long Stroke dampers are incorporated in this base isolation Total: 8 project for drift control. 1500 kN ± 500mm stroke

Cow Bayou Bridge USA, Texas Taylor Viscous Dampers 2015 Impact application. Buffer used to cushion impact loads Total: 1 upon closing of bridge. 155 kN 100mm stroke

Ever Living Construction Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic A residential project using viscous dampers to dissipate Total: 40 seismic energy. 500 kN ± 75mm stroke

4 Residential Buildings Indonesia, Jakarta Taylor Viscous Dampers 2015 Seismic Four high rise residential towers utilize dampers to dissipate Total: 289 seismic energy and reduce drift. 4000 kN ± 100mm stroke

Today's Fresh Start Charter School USA, Inglewood, CA Taylor Viscous Dampers 2015 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 160 kN ± 75mm stroke

Page 10 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Washington Hospital USA, Fremont, CA Taylor Viscous Dampers 2015 Seismic New base isolated hospital utilizes dampers at the level of the Total: 32 isolators to reduce displacment and provide energy 2225 kN ± 915mm stroke dissipation.

Yuanfu Sanchong Project Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic New residential building uses dampers to reduce deflection Total: 63 and provide energy dissipation. 500 kN ± 55mm stroke

Horngiuu Beitou Project Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic New residential building uses dampers to reduce deflection Total: 16 and provide energy dissipation. 500 kN ± 75mm stroke

Shengxing Jinghua Project Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic New residential building uses dampers to reduce deflection Total: 6 and provide energy dissipation. 500 kN ± 75mm stroke

Test Stand for a Space Exploration USA Taylor Viscous Dampers 2015 Vibration Dampers used to reduce vibrations in piping for a test facility. Company Total: 9 735 kN ± 25mm stroke

555 Capitol Mall USA, Sacramento, CA Taylor Viscous Dampers 2015 Seismic Seismic upgrade of two 14 storey office buildings. Dampers Total: 16 used to reduce displacment and provide energy dissipation. 1500 kN ± 125mm stroke

High Tech Facility USA, Santa Clara, CA Taylor Viscous Dampers 2015 Seismic Voluntary seismic upgrade of a high tech facility with Total: 12 dampers in diagonal braces. 1500 kN ± 125mm stroke

Nagasaki Government Building Japan, Nagasaki Taylor Viscous Dampers 2015 Seismic Dampers used to provide energy dissipation and reduce Total: 7 displacement due to earthquake motion. 1200 kN ± 50mm stroke These Dampers are installed to between the building and the building by horizontally.

Page 11 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Loma Linda University Medical Center USA, Loma Linda, CA Taylor Viscous Dampers 2015 Seismic New base isolated hospital utilizes dampers at the level of the Total: 82 isolators to reduce displacment and provide energy 3000 kN ± 1067mm stroke dissipation.

TSMC FAB #15, P5 Taiwan, Tainan Taylor Viscous Dampers 2015 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 52 dissipate seismic energy and reduce vibrations in earthquake. 2000 kN ± 75mm stroke

Phone Company Data Center Turkey Taylor Viscous Dampers 2015 Seismic Base isolated structure uses dampers at the level of the Total: 12 isolators to reduce displacement. 1700 kN ± 610mm stroke

Yinchuan Yellow River Bridge China Taylor Viscous Dampers 2015 Seismic New bridge uses dampers to control longitudianl movement. Total: 6 5016 kN ± 396mm stroke 2374 kN ± 300mm stroke

432 Park Avenue USA, New York, NY Taylor Viscous Dampers 2015 Wind New 89-story, 426m tall reinforced concrete structure uses Total: 16 dampers as part of a Tuned Mass Damper to improve 133 kN ± 1016mm stroke occupant comfort during wind storms.

Naval Medical Center San Diego USA, San Diego, CA Taylor Viscous Dampers 2015-2016 Seismic Retrofit of steel moment frame structure uses dampers in Total: 163 diagonal bracing elements to dissipate seismic energy. 900 kN ± 225mm stroke

29 Palms Naval Hospital USA, 29 Palms, CA Taylor Viscous Dampers 2015 Seismic Retrofit of steel moment frame structure uses dampers in Total: 53 diagonal bracing elements to dissipate seismic energy. 900 kN ± 225mm stroke 181 Fremont Street USA, San Francisco, CA Taylor Viscous Dampers 2015 Seismic & Wind Custom long life metal bellows dampers used with megabraces Total: 32 to control seismic and wind vibrations in a new 54-story, 244m 2000 kN ± 150mm stroke tall mixed use building

Shiji Railway Bridge China, Shandong Taylor Lock-Up Devices 2015 Seismic New bi-purpose continuous steel with 180m main Total: 12 span uses LUDs between the bridge truss and piers to 4000 kN ± 150mm stroke distribute seismic/braking loads.

Page 12 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Boeing Building 3-390 USA Taylor Viscous Dampers 2015 Seismic Flight test hangar uses external diagonal struts with dampers Total: 2 to absorb seismic energy. 3115 kN ± 325mm stroke

Farglory H99 Taiwan, Xinbei City Taylor Viscous Dampers 2015 Seismic A residential project consisting of two 23-story SRC buildings, Total: 72 using viscous dampers to dissipate seismic energy. 1000 kN ± 75mm stroke

Academia Sinica Taiwan, Taipei Taylor Viscous Dampers 2015 Seismic New 6-story research center project, dampers are installed in Total: 10 a base isolation system to reduce earthquake movement. 1600 kN ± 610mm stroke

CEC B7-Xinyi Building Taiwan, Taipei City Taylor Viscous Dampers 2015 Seismic A residential project consists of two 31-story steel structures, Total: 208 using viscous dampers to reduce wind-induced vibrations. 500 kN ± 55mm stroke

12 Moorhouse Avenue New Zealand, Christchurch Taylor Viscous Dampers 2015 Seismic Office building application, part of the rebuild from the Total: 55 Christchurch Earthquakes 250 kN ± 75mm stroke 500 kN ± 100mm stroke 750 kN ± 100mm stroke 1000 kN ± 100mm stroke

SFKH Banqiao Financial Center Taiwan, Xinbei City Taylor Viscous Dampers 2015 Seismic Fluid viscous dampers are used in this steel structure to reduce Total: 22 vibration under earthquakes. 1000 kN ± 100mm stroke

Sunpo Zhubei Taiwan, Hsinchu City Taylor Viscous Dampers 2015 Seismic Fluid viscous dampers are used to reduce vibration under Total: 8 earthquakes. 500 kN ± 75mm stroke

Taoyuan Building Taiwan, Taoyuan Taylor Viscous Dampers 2015 Seismic New 26-story RC residential building uses dampers to Total: 36 dissipate seismic energy. 500 kN ± 75mm stroke

Weihua Taoyuan Building Taiwan, Taoyuan City Taylor Viscous Dampers 2015 Seismic A residential project using fluid viscous dampers to reduce Total: 41 seismic vibrations. 500 kN ± 75mm stroke

Insurance Company Office Building USA, Los Angeles, CA Taylor Viscous Dampers 2015 Seismic Retrofit of an office building uses dampers to enhance seismic Total: 22 performance. 2700 kN ± 125mm stroke

Page 13 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Banco De La Nacion Building Peru, Lima Taylor Viscous Dampers 2015 Seismic New building uses dampers to enhance seismic performance. Total: 16 2600 kN ± 75mm stroke

Futsang Dazhu Building Taiwan, Taoyuan City Taylor Viscous Dampers 2015 Seismic A residential project using fluid viscous dampers to reduce Total: 20 seismic vibrations. 500 kN ± 55mm stroke

Pacifico Insurance Building Peru, Lima Taylor Viscous Dampers 2015 Seismic New building uses dampers to enhance seismic performance. Total: 48 650 kN ± 75mm stroke

Nashua Street Residences USA, Boston, MA Taylor Viscous Dampers 2015 Seismic/Wind New 38 story residential building uses dampers in toggle Total: 30 braces to reduce acceleration and displacement during wind 150 kN ± 250mm stroke storms.

Kioi Building Japan, Tokyo Taylor Viscous Dampers 2015 Seismic New 162m, 33-story steel frame building for hotel, offices and Total: 269 stores uses dampers to dissipate earthquake energy. 2000 kN ± 75mm stroke

San Diego Central Courthouse USA, San Diego, CA Taylor Viscous Dampers 2015 Seismic New 22 story steel moment frame building uses dampers to Total: 106 reduce displacements in the weak direction. 2000 kN ± 125mm stroke 1500 kN ± 100mm stroke

Tu-Cheng "Hi Oasis" Building Taiwan, Xinbei City Taylor Viscous Dampers 2015 Seismic Fluid viscous dampers are used in two residential buildings to Total: 72 reduce structural responses under earthquakes. 500 kN ± 75mm stroke

Kentucky Lake Bridge USA, KY Taylor Viscous Dampers 2015 Seismic Seismic protection of bridge deck at the end bents and main- Total: 24 span piers for an important evacuation route in Kentucky. 667 kN ± 305mm stroke 2700 kN ± 305mm stroke

Shetang Weihe Bridge China, Gansu Tianshui Taylor Viscous Dampers 2015 Seismic New railway continuous beam bridges use dampers to Total: 32 dissipate seismic energy. 4000 kN ± 450mm stroke 1500 kN ± 450mm stroke

Bosphorous Bridge Turkey, Istanbul Taylor Viscous Dampers 2015 Seismic Seismic protection of an existing bridge - one of the busiest Total: 4 crossroads in the world, connecting Asia and Europe. 1700 kN ± 900mm stroke

Page 14 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Panjin Lanhua Pedestrian Bridge China, Liaoning Taylor Viscous Dampers 2015 Pedestrian New Pedestrian Bridge utilizes viscous dampers as part of a Total: 12 Induced tuned mass damping system to control pedestrian induced 5 kN ± 50mm stroke Vibrations vibrations.

Ichigaya New Plant Japan, Tokyo Taylor Viscous Dampers 2015 Seismic New 27m, 5-story steel frame factory building uses dampers Total: 34 to dissipate earthquake energy. 3500 kN ± 125mm stroke 2500 kN ± 125mm stroke

Xinjian Changji Yaxinjiayuan Building China, Xinjiang Taylor Viscous Dampers 2014-2015 Seismic Building added 10 stories. Toggle braces with dampers added Total: 15 to reduce earthquake demand. 750 kN ± 75mm stroke

Rio Tinto Plant #5 USA, CA Taylor Viscous Dampers 2014 Seismic Dampers used to allow thermal movements in a heated piping Total: 2 off-gas system, while providing stability for earthquake 250 kN ± 75mm stroke shaking and vibrations.

Hebei Normal University Volleyball China, Shijiazhuang Taylor Viscous Dampers 2014 Floor Vibrations New stadium uses dampers in TMDs to reduce floor Pavilion Total: 48 vibrations. 2 kN ± 50mm stroke

Costa Del Sol Building Peru, Lima Taylor Viscous Dampers 2014 Seismic New building uses dampers to enhance seismic performance. Total: 16 500 kN ± 75mm stroke 700 kN ± 75mm stroke

Palo Alto Church USA, Palo Alto, CA Taylor Viscous Dampers 2014 Seismic First Congregational Church uses a pair of dampers to Total: 2 dynamically stabilize/dissipate earthquake energy between 250 kN ± 75mm stroke masonry cross-wall & wood shear-wall building.

351 California Street USA, San Francisco, CA Taylor Viscous Dampers 2014 Seismic Dampers used in diagonal bracing for this voluntary seismic Total: 6 retrofit of a 2-story steel framed building. 2150 kN ± 125mm stroke

Xin-Zhuang Building Taiwan, New Taipei Taylor Viscous Dampers 2014 Seismic New 22-story RC residential building uses dampers to Total: 28 dissipate seismic energy. 500 kN ± 55mm stroke

Farglory H105 Taiwan, Xinbei City Taylor Viscous Dampers 2014 Seismic A residential building using fluid viscous dampers to dissipate Total: 12 seismic energy. 500 kN ± 75mm stroke

Page 15 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Farglory H88 Taiwan, Xinbei City Taylor Viscous Dampers 2014 Seismic Fluid viscous dampers are used in two 40-story residential Total: 240 buildings to dissipate seismic energy. 1000 kN ± 75mm stroke

Farglory H113 Taiwan, Xinbei City Taylor Viscous Dampers 2014 Seismic Fluid viscous dampers are used in this residential buildings to Total: 96 dissipate seismic energy. 1000 kN ± 75mm stroke

Mazzoni Hospital Italy Taylor Viscous Dampers 2014 Seismic Hospital building uses dampers in diagonal bracing elements Total: 6 to dissipate seismic energy. 350 kN ± 75mm stroke

Danfeng Building Taiwan, Xinbei City Taylor Viscous Dampers 2014 Seismic Project consisting five residential buildings uses fluid viscous Total: 160 dampers to dissipate seismic energy. 500 kN ± 55mm stroke

Pearl Harbor Memorial Bridge USA, New Haven, CT Taylor Cable Dampers 2014 Wind/Rain New cable-stayed bridge. Dampers attached to cables to Total: 96 reduce vibrations caused by a combination of wind and rain. 8 kN ± 50mm stroke

Taota Building #21 Taiwan Taylor Viscous Dampers 2014 Seismic Fluid viscous dampers are used in this residential buildings to Total: 40 dissipate seismic energy 500 kN ± 75mm stroke

Taota Building #22 Taiwan Taylor Viscous Dampers 2014 Seismic Fluid viscous dampers are used in this residential buildings to Total: 80 dissipate seismic energy 500 kN ± 75mm stroke Turkcell Maltepe 2 Turkey Taylor Viscous Dampers 2014 Seismic Office building use dampers in diagonal bracing elements to Total: 36 dissipate seismic energy. 750 kN ± 100mm stroke

Lima Airport Peru, Lima Taylor Viscous Dampers 2014 Seismic Retrofit of airport terminal uses dampers to improve Total: 14 earthquake protection. 1500 kN ± 75mm stroke 750 kN ± 75mm stroke

Tower of Hope (Crystal Cathedral) USA, Garden Grove, CA Taylor Viscous Dampers 2014 Seismic Retrofit of theater building uses dampers in diagonal braces to Total: 32 reduce displacement and to dissipate seismic energy. 1150 kN ± 100mm stroke

Tianningsi Bridge China, Beijing Taylor Viscous Dampers 2014 Seismic Retrofit of steel girder bridge. Dampers used between girders Total: 22 and abutments to reduce earthquake displacements. 500 kN ± 75mm stroke

Page 16 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Yunnan Longjiang Bridge China, Yunnan Taylor Viscous Dampers 2014 Seismic New suspension bridge with 1196m main span uses dampers Total: 8 between the bridge deck and piers to control the movement 2850 kN ± 1000mm stroke due to seismic, vehicle and wind loads.

Ridgefield NWR Pedestrian Bridge USA, Ridgefield, WA Taylor Viscous Dampers 2014 Pedestrian New pedestrian bridge uses dampers as part of a TMD system Total: 6 to control pedestrian induced vibrations. 1 kN ± 75mm stroke

GTG Breeze Center Taiwan, New Taipei Taylor Viscous Dampers 2014 Seismic Project consists of three 20-story RC residential building uses Total: 30 dampers to dissipate seismic energy. 500 kN ± 75mm stroke

Salem Parking Garage USA, Salem, MA Taylor Lock-Up Devices 2014 Seismic Lock-up devices used to connect all the building sections Total: 32 together during a seismic event, but allow for thermal motion. 150 kN ± 25mm stroke

Brielle/Morgan/Shark Bridges USA, NJ Taylor Fluid Dampers 2014 Kinetic Energy of Protection of new bascule leafs from runaway motors and Total: 3 Moving Bridge brake failures 232 kN 305mm stroke Chincoteague Bridge USA, Chincoteague, VA Taylor Fluid Dampers 2014 Kinetic Energy of Protection of new bascule leafs from runaway motors and Total: 2 Moving Bridge brake failures 475 kN 405mm stroke

Santa Clarita City Hall USA, Santa Clarita, CA Taylor Viscous Dampers 2014 Seismic Retrofit of 3 story building uses dampers to enhance seismic Total: 28 performance and allow the structure to remain functional 1500 kN ± 75mm stroke after a large earthquake.

South 200th Link Light Rail (S440) USA, Seattle, WA Taylor Lock-Up Devices 2015 Seismic Elevated light rail system uses shock transmission units to Total: 20 control seismic movement/allow free thermal movement in 2115 kN ± 75mm stroke section near SEATAC airport. 1780 kN ± 150mm stroke 2890 kN ± 150mm stroke

Xinjiang Wuqia Building China Taylor Viscous Dampers 2014 Seismic/Wind New building uses dampers to enhance seismic performance Total: 72 and reduce wind inducted vibrations. 750 kN ± 75mm stroke

Farglory H111 Taiwan, Xinbei City Taylor Viscous Dampers 2014 Seismic A residential building uses fluid viscous dampers to dissipate Total: 136 seismic energy. 500 kN ± 75mm stroke

Farglory H109 Taiwan, Xinbei City Taylor Viscous Dampers 2014 Seismic A residential building uses fluid viscous dampers to dissipate Total: 38 seismic energy. 500 kN ± 75mm stroke

Page 17 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Jinghang Canal Bridge China Taylor Viscous Dampers 2014 Seismic New cable-stayed bridge uses dampers to protect the structure Total: 4 during earthquakes. 1700 kN ± 200mm stroke

Computa-Floor Vibration USA Taylor Viscous Dampers 2014 Mechanical Total: 1 Vibration 75 kN ± 75mm stroke

Yeongi Bridge South Korea Taylor Viscous Dampers 2014 Seismic Seismic retrofit of a bridge using dampers. Total: 2 500 kN ± 150mm stroke

Haramain High Speed Railway Saudi Arabia Taylor Viscous Dampers 2014 Seismic Lock-up Devices used to connect sections together of thie HSR. Total: 14 500 kN ± 50mm stroke TSMC FAB #12, P7 Taiwan, Tainan Taylor Viscous Dampers 2013 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 44 dissipate seismic energy and reduce vibrations in earthquake. 2000 kN ± 75mm stroke

TSMC FAB #14, P7 Taiwan, Tainan Taylor Viscous Dampers 2013 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 52 dissipate seismic energy and reduce vibrations in earthquake. 1500 kN ± 75mm stroke

Xinjiang Atushi Building China Taylor Viscous Dampers 2013 Seismic/Wind New construction, building uses dampers with toggle braces to Total: 56 reduce motion caused by wind storms. 750 kN ± 75mm stroke

Bnei Zion Hospital Israel, Haifa Taylor Viscous Dampers 2013 Seismic Retrofit of a Hospital building uses dampers to dissipate Total: 20 seismic energy in earthquake, by toggle system assembly. 600 kN ± 75mm stroke

GTG - Century Center Taiwan, New Taipei Taylor Viscous Dampers 2013 Seismic New project consists of two 23-story RC residential building Total: 40 uses dampers to dissipate seismic energy. 500 kN ± 75mm stroke

Quinde Mall Peru, Lima Taylor Viscous Dampers 2013 Seismic Dampers used in diagonal braces for seismic energy Total: 8 absorption. 1400 kN ± 75mm stroke

Criterion Theater USA, Los Angeles, CA Taylor Viscous Dampers 2013 Seismic Dampers used in diagonal braces to improve seismic Total: 14 performance of an historic theater. 1200 kN ± 100mm stroke

Page 18 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Deshengmen Bridge China, Beijing Taylor Viscous Dampers 2013 Seismic Retrofit of steel girder bridge. Dampers used between girders Total: 32 and abutments to reduce earthquake displacements. 500 kN ± 75mm stroke

Andingmen Bridge China, Beijing Taylor Viscous Dampers 2013 Seismic Retrofit of steel girder bridge. Dampers used between girders Total: 32 and abutments to reduce earthquake displacements. 500 kN ± 75mm stroke

Farglory H75 Taiwan Taylor Viscous Dampers 2013 Seismic A residential building uses fluid viscous dampers to dissipate Total: 32 seismic energy. 1000 kN ± 75mm stroke Quangzhou Bay Bridge China Taylor Viscous Dampers 2013 Seismic New cable-stayed bridge with 400m main span uses dampers Total: 8 to protect the structure during earthquakes. 2500 kN ± 480mm stroke

Boeing Building 40-51 USA, Everett, WA Taylor Viscous Dampers 2013 Seismic Dampers used in diagonal braces for earthquake protection of Total: 17 this seismic strengthening/upgrade project. 1780 kN ± 100mm stroke

Zanfu Dunnan Street Building Taiwan, Xinbei City Taylor Viscous Dampers 2013 Seismic Fluid viscous dampers are used in this residential building to Total: 50 dissipate seismic energy. 1000 kN ± 75mm stroke

Yue Young Xinzhuang Building Taiwan, New Taipei Taylor Viscous Dampers 2013 Seismic New 16-story RC residential building uses dampers to Total: 12 dissipate seismic energy. 500 kN ± 75mm stroke

Stonestown Mall - Apple Store USA, San Francisco, CA Taylor Viscous Dampers 2013 Seismic Total: 4 1500 kN ± 75mm stroke

BART - Pleasant Hill Station USA, Pleasant Hill, CA Taylor Viscous Dampers 2013 Seismic Total: 4 1350 kN ± 100mm stroke

Paohuei Taichung Taiwan, Taichung Taylor Viscous Dampers 2013 Seismic Total: 148 500 kN ± 55mm stroke

Tan Mei Office Building Taiwan, Taipei Taylor Viscous Dampers 2013 Seismic Project consists of two 12-story SC office building uses Total: 32 dampers to dissipate seismic energy. 600 kN ± 75mm stroke

Page 19 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Steel Mill Recouperator USA, Burns Harbor, IN Taylor Lock-Up Devices 2013 Aging recuperator stacks utilize Lock-Up Devices to prevent Total: 28 total collapse as a result of cracking in the stacks. 500 kN ± 100mm stroke

Farglory H108 Taiwan, Xinbei City Taylor Viscous Dampers 2013 Seismic Fluid viscous dampers are used in this residential building to Total: 16 dissipate seismic energy. 500 kN ± 75mm stroke

Farglory H89 Taiwan, Xinbei City Taylor Viscous Dampers 2013 Seismic Fluid viscous dampers are used in this residential building to Total: 47 dissipate seismic energy. 500 kN ± 75mm stroke

Jiangshan Project Taiwan Taylor Viscous Dampers 2013 Seismic Fluid viscous dampers are used in this residential building to Total: 4 dissipate seismic energy. 500 kN ± 75mm stroke

Gilbert House USA, CA Taylor Viscous Dampers 2013 Seismic Residential structure uses FVDs for energy dissipation Total: 13 133 kN ± 75mm stroke

Haneda Airport Japan, Tokyo Taylor Viscous Dampers 2013 Seismic New 5-story steel frame building for the facilities of the Total: 8 airport, connects new 7-story steel frame 2 buildings for 2000 kN ± 125mm stroke facilities of the airport like a bridge. The space beneath the bridge, between the 2 buildings is vacant with no structure. Dampers used to dissipate earthquake energy.

Yelin Zhubei Taiwan, Hinzhu Taylor Viscous Dampers 2013 Seismic New 19-story RC residential building uses dampers to Total: 20 dissipate seismic energy. 500 kN ± 55mm stroke

Chicony Electronics HQ Taiwan, New Taipei Taylor Viscous Dampers 2013 Seismic/Wind New 39-story SRC office building uses dampers to dissipate Total: 100 seismic & wind energy. 1000 kN ± 75mm stroke

TSMC FAB #14, P6 Taiwan, Tainan Taylor Viscous Dampers 2013 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 52 dissipate seismic energy and reduce vibrations in earthquake. 1500 kN ± 75mm stroke

Farglory H106 Taiwan, Taipei City Taylor Viscous Dampers 2013 Seismic Residential project uses fluid viscous dampers to dissipate Total: 92 seismic energy. 1000 kN ± 75mm stroke

Page 20 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Yoji Daheng Project Taiwan, Taichung City Taylor Viscous Dampers 2013 Seismic Fluid viscous dampers are used in steel structure to reduce Total: 134 wind vibrations. 750 kN ± 50mm stroke

Huaku Song-Jiang Project Taiwan, Taipei City Taylor Viscous Dampers 2013 Seismic Fluid viscous dampers are used in steel structure to reduce Total: 16 vibrations under earthquakes. 1000 kN ± 75mm stroke

TSMC FAB #124, P5/P6 Taiwan, Tainan Taylor Viscous Dampers 2013 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 29 dissipate seismic energy and reduce vibrations in earthquake. 1500 kN ± 75mm stroke

Haramain High Speed Railway Saudi Arabia Taylor Viscous Dampers 2013 Seismic Total: 34 500 kN ± 50mm stroke

Farglory H102 Taiwan, Taichung City Taylor Viscous Dampers 2013 Seismic Fluid viscous dampers are used in steel structure to dissipate Total: 72 seismic energy. 500 kN ± 75mm stroke

Danish Marine Museum Denmark, Helsingor Taylor Viscous Dampers 2013 Pedestrian Dampers used to reduce vibrations and improve pedestrian Total: 3 comfort. 20 kN ± 111mm stroke

Kichijyouji Station Japan, Tokyo Taylor Viscous Dampers 2013 Seismic New 10-story steel frame building for station/offices uses Total: 75 dampers to dissipate earthquake energy. 500 kN ± 75mm stroke

Farglory H96 Taiwan, New Taipei Taylor Viscous Dampers 2013 Seismic New 23-story RC residential building uses viscous dampers to Total: 44 dissipate seismic energy. 1000 kN ± 75mm stroke Qinshi #3 Provence Taiwan, YiLan Taylor Viscous Dampers 2013 Seismic Long Stroke dampers are incorporated in this base isolation Total: 4 project for drift control 2000 kN ± 610mm stroke

Farglory H93 Taiwan, New Taipei Taylor Viscous Dampers 2013 Seismic Project consists of three 23-story RC residential buildings that Total: 92 use viscous dampers to dissipate seismic energy. 1000 kN ± 75mm stroke

Neimeng Wuxi Bridge China Taylor Viscous Dampers 2012 Seismic New railway bridge , uses dampers to protect the structure Total: 48 during earthquakes. 2000 kN ± 450mm stroke

Page 21 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Jiangxi Jiujiang Bridge China Taylor Viscous Dampers 2012 Seismic New cable-stayed bridge with 818m main span uses dampers Total: 8 to protect the structure during earthquakes. 1500 kN ± 850mm stroke

Yahoo Phase 2 USA, Santa Monica, CA Taylor Viscous Dampers 2012 Seismic Voluntary seismic upgrade uses dampers to dissipate seismic Total: 70 energy. 2000 kN ± 100mm stroke Chiba Station West Gate Japan, Chiba Taylor Viscous Dampers 2012 Seismic New 11-story steel frame office/commercial building uses Total: 16 dampers to dissipate seismic energy. 1100 kN ± 50mm stroke Portland Galleria Bldg. USA, Portland, OR Taylor Viscous Dampers 2012 Seismic Historic, terra cotta clad, 5-story, full block department store Total: 64 building constructed in 1910. Riveted steel frame to be 778 kN ± 100mm stroke protected by dampers in chevron drivers dissipating seismic 1445 kN ± 100mm stroke energy. 1780 kN ± 100mm stroke

CE Reducto Gerpal Building Peru, Lima Taylor Viscous Dampers 2012 Seismic New building uses dampers to dissipate seismic energy. Total: 30 1400 kN ± 100mm stroke

New Nonsan Grand Bridge South Korea, Nonsan Taylor Viscous Dampers 2012 Seismic Seismic retrofit of a 500m, multi-span, steel girder bridge. Total: 8 750 kN ± 150mm stroke

Byeongieom Bridge South Korea, Hwaseong Taylor Viscous Dampers 2012 Seismic Tuned Mass Damper (TMD) System used to control vertical Total: 32 vibrations caused by vehicle traffic. 9 kN ± 50mm stroke Three Gorges Ship Lift China, Wuhan Taylor Viscous Dampers 2012 Seismic Shock absorbers are used on shiplift to resist earthquakes. Total: 3 1500 kN ± 100mm stroke Patio Mayor Project #945 Chile Taylor Viscous Dampers 2012 Seismic Total: 36 550 kN ± 75mm stroke

Dexin Hsin-Chu A+7 Taiwan, Hsin Chu Taylor Viscous Dampers 2012 Seismic New SRC residential building uses viscous dampers to Total: 66 dissipate seismic energy. 500 kN ± 75mm stroke

Qinshi #3 Tuscany Taiwan, YiLan Taylor Viscous Dampers 2012 Seismic Long Stroke dampers are incorporated in this base isolation Total: 8 project for drift control 500 kN ± 500mm stroke

Forworld Fuzhong Taiwan, New Taipei Taylor Viscous Dampers 2012 Seismic New SRC residential building uses viscous dampers to Total: 60 dissipate seismic energy. 50 kN ± 75mm stroke

Page 22 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Corning Tainan Building A Taiwan, Tainan Taylor Viscous Dampers 2012 Seismic Uses dampers to dissipate earthquake energy. Total: 137 2000 kN ± 75mm stroke 2700 kN ± 75mm stroke 1700 kN ± 75mm stroke 2500 kN ± 75mm stroke

Ruentex Botanical Gardens Taiwan, Taipei Taylor Viscous Dampers 2012 Seismic Long Stroke dampers are incorporated in this base isolation Total: 6 project for drift control 1000 kN ± 750mm stroke 2000 kN ± 750mm stroke Digua Building Taylor Viscous Dampers 2012 Seismic Total: 16 1500 kN ± 100mm stroke

Corning Taichung Phase 1 Taiwan, Taichung Taylor Viscous Dampers 2012 Seismic Uses dampers to dissipate earthquake energy. Total: 102 2800 kN ± 75mm stroke 3500 kN ± 125mm stroke 3300 kN ± 100mm stroke

Corning Tainan Building B Taiwan, Tainan Taylor Viscous Dampers 2012 Seismic Uses dampers to dissipate earthquake energy. Total: 110 2700 kN ± 75mm stroke 3500 kN ± 100mm stroke 3100 kN ± 100mm stroke 4900 kN ± 120mm stroke 4600 kN ± 120mm stroke 4300 kN ±120mm stroke 3900 kN ± 100mm stroke

Vida Security Chile Taylor Viscous Dampers 2012 Seismic Total: 84 650 kN ± 100mm stroke

Canberra Bridge Australia Taylor Viscous Dampers 2012 Seismic Total: 4 500 kN ± 100mm stroke

Chonghong Xihu Taiwan, Taipei Taylor Viscous Dampers 2012 Seismic New 28-story SRC residential building uses viscous dampers Total: 112 to dissipate seismic energy. 1000 kN ± 75mm stroke 500 kN ± 75mm stroke Talca Hospital Chile Taylor Viscous Dampers 2012 Seismic Total: 40 500 kN ± 75mm stroke

Page 23 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Papermart USA, Orange, CA Taylor Viscous Dampers 2012 Seismic Total: 4 735 kN ± 75mm stroke

Beehive Clothing USA, Utah Taylor Viscous Dampers 2012 Seismic Total: 8 1500 kN ± 2" stroke 3000 kN ± 2" stroke Taota #20 Project Taiwan, Taoyuan Taylor Viscous Dampers 2012 Seismic New RC residential building uses viscous dampers to dissipate Total: 16 seismic energy. 500 kN ± 75mm stroke Uni-President Zhubei Taiwan, Hsin Chu Taylor Viscous Dampers 2012 Seismic New RC residential building uses viscous dampers to dissipate Total: 28 seismic energy. 500 kN ± 75mm stroke Corning Taichung Phase 2 Taiwan, Taichung Taylor Viscous Dampers 2012 Seismic Uses dampers to dissipate earthquake energy. Total: 99 2500 kN ± 75mm stroke 2800 kN ± 75mm stroke 3600 kN ± 75mm stroke 3200 kN ± 75mm stroke 4200 kN ± 100mm stroke San Bernardino Justice USA, San Bernardino, CA Taylor Viscous Dampers 2012 Seismic Total: 184 2000 kN ± 125mm stroke Win Sing Xin Yi G1 Taiwan, Taipei Taylor Viscous Dampers 2012 Seismic New SRC residential building uses viscous dampers to Total: 120 dissipate seismic energy. 500 kN ± 55mm stroke 800 kN ± 75mm stroke

New Jerusalem Elementary School USA, Tracy, CA Taylor Viscous Dampers 2012 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 160 kN +/- 75mm stroke TSMC FAB #15, Phase 3 Taiwan, Taichung Taylor Viscous Dampers 2012 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 28 dissipate seismic energy and reduce vibrations in earthquake. 2000 kN± 75mm stroke

Farglory H90 Taiwan, New Taipei Taylor Viscous Dampers 2012 Seismic New 24-story RC residential building uses viscous dampers to Total: 80 dissipate seismic energy. 1000 kN ± 75mm stroke

Farglory H91 Taiwan, New Taipei Taylor Viscous Dampers 2012 Seismic New 23-story RC residential building uses viscous dampers to Total: 44 dissipate seismic energy. 1000 kN ± 75mm stroke

Page 24 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Farglory H92 Taiwan, New Taipei Taylor Viscous Dampers 2012 Seismic New RC residential building uses viscous dampers to dissipate Total: 44 seismic energy. 1000 kN ± 75mm stroke Taifer Nangang Taiwan, Taipei Taylor Viscous Dampers 2012 Seismic New SRC residential building uses viscous dampers to Total: 56 dissipate seismic energy. 500 kN ± 75mm stroke Chengmao Xinzhuang Taiwan, New Taipei Taylor Viscous Dampers 2012 Seismic New RC residential building uses viscous dampers to dissipate Total: 28 seismic energy. 500 kN ± 75mm stroke

Tianjin Guomao China, Tianjin Taylor Viscous Dampers 2012 Seismic New 60-story building uses fluid dampers to reduce seismic Total: 12 and wind vibrations. 1000 kN ±100mm stroke Luzhou 709 Taiwan, New Taipei Taylor Viscous Dampers 2012 Seismic New 11- story RC residential project uses dampers to dissipate Total: 14 earthquake energy. 500 kN ± 75mm stroke

Taipower Wang Long Taiwan, Taipei Taylor Viscous Dampers 2012 Seismic New 15-story SRC electrical substation uses dampers to Total: 271 reduce seismic responses. 500 kN ± 50mm stroke 1000 kN ± 50mm stroke 3300 Webster USA, Oakland, CA Taylor Viscous Dampers 2012 Seismic Total: 12 750 kN ± 150mm stroke 1500 kN ± 150mm stroke Pismo Beach Athletic Club USA, Pismo Beach, CA Taylor Viscous Dampers 2012 Seismic Total: 10 135 kN ± 75mm stroke TSMC FAB #14, P5 Taiwan, Tainan Taylor Viscous Dampers 2012 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 52 dissipate seismic energy and reduce vibrations in earthquake. 1500 kN ± 75mm stroke

Haramain HSR Saudi Arabia Taylor Viscous Dampers 2012 Seismic Total: 64 500 kN ± 75mm stroke Fubon Dun-Nan Taiwan, Taipei Taylor Viscous Dampers 2012 Seismic New 17-story steel residential building uses viscous dampers to Total: 28 dissipate seismic energy. 1000 kN ± 100mm stroke 1500 kN ± 100mm stroke

Page 25 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Santiago Creek Bridge USA, Irvine, CA Taylor Viscous Dampers 2011 Seismic Total: 6 700 kN ± 381mm stroke

Corning Taichung Phase 4 Taiwan, Taichung Taylor Viscous Dampers 2011 Seismic Uses dampers to dissipate earthquake energy. Total: 65 4500 kN ± 125mm stroke 4200 kN ± 100mm stroke 3900 kN ± 75mm stroke 3500 kN ± 75mm stroke

Mumbai Airport - Terminal 2 India, Mumbai Taylor Viscous Dampers 2011 Seismic/ Wind Fluid Viscous Dampers have been installed between the Total: 66 column and roof junction against seismic and wind forces 250 kN ± 75mm stroke action on the curtain walls.

Yihua Dazhi Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic Project includes two 42-story SRC residential buildings and Total: 265 one 39-story SRC hotel building. Dampers are used to reduce 1000 kN ± 75mm stroke seismic responses.

Marneris (Greece) Protas Eniskyes Greece Taylor Viscous Dampers 2011 Seismic Seismic upgrade of a 6-story residential building. Dampers Total: 16 used in diagonal braces to dissipate seismic energy. 250 kN ± 75mm stroke

Corning Taichung Phase 3 Taiwan, Taichung Taylor Viscous Dampers 2011 Seismic Uses dampers to dissipate earthquake energy. Total: 90 1000 kN ± 100mm stroke 1200 kN ± 100mm stroke 1500 kN ± 150mm stroke 1800 kN ± 75mm stroke 2000 kN ± 125mm stroke 2500 kN ± 175mm stroke

Las Condes Capital Chile Taylor Viscous Dampers 2011 Seismic Total: 46 850 kN ± 100mm stroke TSMC #12 P6 Taiwan, Hsin Chu Taylor Viscous Dampers 2011 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 40 dissipate seismic energy and reduce vibrations in earthquake. 2000 kN ± 75mm stroke Farglory H85 Taiwan, New Taipei Taylor Viscous Dampers 2011 Seismic New 25-story RC residential building uses viscous dampers to Total: 96 dissipate seismic energy. 1000 kN ± 75mm stroke Farglory H86 Taiwan, New Taipei Taylor Viscous Dampers 2011 Seismic New RC residential building uses viscous dampers to dissipate Total: 128 seismic energy. 1000 kN ± 75mm stroke

Page 26 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information 2020 Lawrence USA, Denver, CO Taylor Viscous Dampers 2011 Seismic Total: 10 225 kN ± 50mm stroke Taota Taoyuan 19th Taiwan, Taoyuan Taylor Viscous Dampers 2011 Seismic New RC residential building uses viscous dampers to dissipate Total: 40 seismic energy. 500 kN ± 75mm stroke Chinatrust Headquarters Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic Dampers are installed in this steel structure to reduce Total: 367 structural responses in earthquakes. 1500 kN ± 75mm stroke 1000 kN ± 75mm stroke 1000 kN ± 80mm stroke Carranza Stadium Spain Taylor Viscous Dampers 2011 Seismic Dampers used to protect the roof of a new stadium. Total: 2 500 kN ± 75mm stroke Corning Taichung P6M Taiwan, Taichung Taylor Viscous Dampers 2011 Seismic Uses dampers to dissipate earthquake energy. Total: 98 1860 kN ± 50mm stroke 2720 kN ± 50mm stroke 2720 kN ± 75mm stroke 2720 kN ± 100mm stroke 2720 kN ± 125mm stroke 3400 kN ± 150mm stroke 125 Rue Faubert Haiti Taylor Viscous Dampers 2011 Seismic Total: 20 26,000 kN ± 4" stroke Unibank Haiti Haiti Taylor Viscous Dampers 2011 Seismic Total: 16 25800 kN ± 4" stroke Cementos Bio Bio Chile Taylor Viscous Dampers 2011 Seismic Total: 1 25 MT ± 75mm stroke Carranza Stadium Spain Taylor Viscous Dampers 2011 Seismic Total: 2 500 kN ± 75mm stroke Chochun 2nd Bridge South Korea, Yeongi Taylor Viscous Dampers 2011 Seismic Seismic retrofit of a 150m, multi-span, PSC-. Total: 2 500 kN ± 150mm stroke QVC Japan Project Japan, Chiba Taylor Viscous Dampers 2011 Seismic Dampers used as part of a base isolation system for a new 7 Total: 8 story 37,174 m^2 steel frame building. 1450 kN ± 610mm stroke Rosario North Project Chile Taylor Viscous Dampers 2011 Seismic Total: 52 650 kN ± 100mm stroke

Page 27 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Shomyo Project Japan, Yokohama City Taylor Viscous Dampers 2011 Seismic New 6-story fixed base steel frame building uses dampers in Kanagawa Total: 38 diagonal braces to absorb earthquake energy. 700 kN ± 100mm stroke 1000 kN ± 100mm stroke 1250 kN ± 100mm stroke 1750 kN ± 100mm stroke Yahoo Center USA, Santa Monica, CA Taylor Viscous Dampers 2011 Seismic Total: 60 2000 kN ± 4" stroke Kimpo Airport South Korea Taylor Viscous Dampers 2011 Seismic Seismic retrofit of terminal buildings. Some dampers were Total: 36 installed at expansion joints and others were installed in toggle 500 kN ± 100mm stroke braces. Lock-Up Devices were used to control seismic 2000 kN ± 100mm stroke movement while allowing free thermal movement. 2000 kN ± 100mm stroke Corning Beijing China Taylor Viscous Dampers 2011 Seismic New plant, dampers in chevron braces to dissipate seismic Total: 59 energy. 800 kN ± 25mm stroke 800 kN ± 75mm stroke 1150 kN ± 100mm stroke 1150 kN ± 100mm stroke BC Place Stadium Canada, Vancouver, BC Taylor Viscous Dampers 2011 Seismic Retrofit of football stadium for seismic protection and to act as Total: 96 an emergency shelter for Vancouver, BC. 2000 kN ± 60mm stroke 1500 kN ± 50mm stroke Beijing Fuchengmen Bridge China, Beijing Taylor Viscous Dampers 2011 Seismic Retrofit of elevated highway bridge uses dampers to control Total: 20 vibration due to vehicle and earthquake. 500 kN Fluid ± 75mm stroke Cal Memorial Stadium USA, Berkeley, CA Taylor Viscous Dampers 2011 Seismic Total: 16 2000 kN Fluid ± 125mm stroke DAK Americas Silo #2 USA, Leland, NC Taylor Dampers 2011 Seismic Total: 20 490 kN ± 100mm stroke DEH Cho Bridge Canada, Northwest Taylor Lock up Devices 2011 Seismic This cable-stayed, new bridge will span the Mackenzie River Territories Total: 40 near Fort Providence & is intended to replace the operations 739 kN ± 270mm stroke of the Merv Hardie Ferry & the Mackenzie Ice Crossing, available to link for all seasons. Farglory H68 Project Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New RC residential project uses dampers to dissipate Total: 48 earthquake energy. 50 MT Damper ± 75mm stroke Farglory H72 Project Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New SRC residential project uses dampers to dissipate Total: 65 earthquake energy. 600 kN ± 75mm stroke

Page 28 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Farglory H73 Project Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New RC residential project uses dampers to dissipate Total: 80 earthquake energy. 500 kN ± 75mm stroke Farglory H80 Project Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New 12-story RC residential project uses dampers to dissipate Total: 12 earthquake energy. 500 kN ± 75mm stroke Fashion Island Theater USA, Newport Beach, CA Taylor Viscous Dampers 2011 Seismic Voluntary seismic upgrade of pre-Northridge construction Total: 20 theatre building, uses viscous dampers in the structural frame 735 kN ± 100mm stroke to reduce seismic response. 1000 kN ± 300mm stroke 1500 kN ± 400mm stroke 1000 kN ± 200mm stroke Fu Yu Project Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic Total: 4 150 kN ± 25mm stroke Fujian Wulongjiang Bridge China, Fujian Taylor Lock up Devices 2011 Seismic Lock-up Devices used to control seismic movement while Total: 4 allowing free thermal movement. 6000 kN ± 300mm stroke Global Team Group #236 Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New 21-story RC residential project uses dampers to dissipate Total: 14 earthquake energy. 500 kN ±75mm stroke Global Team Group #30 Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New 17- story RC residential project uses dampers to dissipate Total: 8 earthquake energy. 500 kN ± 75mm stroke He Huan Hsin-Dien Project Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New 29-story SRC residential project uses dampers to reduce Total: 224 vibrations caused by earthquake. 500 kN ± 100mm stroke Henley Street Bridge USA, Knoxville, TN Taylor Lock up Devices 2011 Seismic Demolition and replacement of the 1,793 foot bridge deck and Total: 20 the vertical, concrete supports above the arches, addition of a 200 kN ± 75mm stroke sixth lane to this 79 year old span across Fort Loudoun Lake. 750 kN ± 100mm stroke Hsin-Lung Nan-Hai Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New SRC residential project uses dampers to dissipate Total: 2 earthquake energy. 500 kN ± 75mm stroke Huaku & Taifer Nan-Gang H6 Project Taiwan, Taipei Taylor Dampers 2011 Seismic New 18-story residential project, dampers are installed with Total: 20 base isolation system to reduce earthquake movement. 900 kN ± 812mm stroke Huaku Hsin Chu Taiwan, HisnChu Taylor Viscous Dampers 2011 Seismic New 25-story SRC residential building uses dampers to Total: 16 dissipate earthquake. 1000 kN ± 75mm stroke Huaku Ji-Lin Project B Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New 14-story SRC residential building uses dampers to Total: 8 dissipate earthquake. 1000 kN ± 75mm stroke

Page 29 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Huaku V-Park Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New construction, a 16-story SRC business building uses Total: 36 dampers to dissipate seismic energy. 500 kN ± 75mm stroke LeTerrazze Shopping Center Italy, La Spezia Taylor Lock up Devices 2011 Seismic Lock-up devices used to link different structural units of a Total: 55 prefabricated concrete building, under seismic actions, thus 1000 kN ± 50mm stroke leaving them separated during normal service. 2000 kN ± 50mm stroke Moonam Bridge South Korea, Goseong Taylor Viscous Dampers 2011 Seismic Seismic retrofit of a 120 m multi-span PSC beam bridge using Total: 4 dampers. 500 kN ± 100mm stroke New Janghowon Bridge South Korea, Eumseong Taylor Viscous Dampers 2011 Seismic Seismic retrofit of a 240 m multi-span PSC beam bridge using Total: 8 dampers. 500 kN ± 100mm stroke Newton Reservoir Canada, Surrey, BC Taylor Viscous Dampers 2011 Seismic Total: 16 1000 kN ± 50mm stroke RCMP Richmond Community Safety Canada, Richmond, BC Taylor Dampers 2011 Seismic This project is to upgrade to post-disaster standards and to Building Total: 20 renovate the existing building to accommodate the new RCMP 600 kN ± 100mm stroke Richmond Headquarters. Sunpo Hong-Yun Project Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New 19-story RC building, uses dampers to dissipate Total: 8 earthquake energy. 500 kN ± 75mm stroke Taichung Factory, P5 & P6 Taiwan, Taichungi Taylor Viscous Dampers 2011 Seismic Total: 117 5400 kN ± 50mm stroke 4300 kN ± 150mm stroke 3600 kN ± 175mm stroke 3400 kN ±175mm stroke 2700 kN ± 150mm stroke 1860 kN ± 50mm stroke Nanguo The Ellipse 360 Tower Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New steel construction, a 28-story residential project uses Total: 153 dampers to reduce vibration caused by wind forces. 1000 kN ± 75mm stroke Tiangjin Qinghuangdao Bridge China, Tianjin Taylor Lock up Devices 2011 Seismic New railway bridge use Lock-up Devices to control bridge Total: 30 deck movement during seismic events. 4000 kN ± 100mm stroke 5000 kN ± 100mm stroke Tiangjin Qinghuangdao Bridge China, Hebei Tangshan Taylor Lock up Devices 2011 Seismic New railway bridge use Lock-up Devices to control bridge Total: 20 deck movement during seismic events. 4500 kN ± 100mm stroke Tonglou Interchange Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic Retrofit of a Highway Interchange uses lock-up devices to Total: 24 control longitudinal movement in earthquake, while allowing 1200 kN ± 100mm stroke free thermal movement.

Page 30 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information TSMC Fab #12, P3 Taiwan, Hsin Chu City Taylor Viscous Dampers 2011 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 20 dissipate seismic energy and reduce vibrations in earthquake. 1200 kN ± 75mm stroke TSMC Fab #15, P1 Taiwan, Taichung Taylor Viscous Dampers 2011 Seismic New semiconductor fabrication plant uses dampers to Total: 14 dissipate seismic energy and reduce vibrations in earthquake. 200 kN ± 75mm stroke TSMC Fab #15, P2 Taiwan, Taichung Taylor Viscous Dampers 2011 Seismic New semiconductor fabrication plant uses dampers to Total: 14 dissipate seismic energy and reduce vibrations in earthquake. 2000 kN ± 75mm stroke WG Group Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New construction, a 26-story RC residential project, uses Total: 38 dampers to reduce earthquake vibrations. 50 MT ± 75mm stroke 50 MT FVED ± 50mm stroke Wuhan Poly Building China, Wuhan Taylor Viscous Dampers 2011 Seismic New structure uses dampers to absorb earthquake energy and Total: 62 reduce deflection and stress. 1000 kN ± 100mm stroke 1200 kN ± 75mm stroke Xiazhang Bridge(North) China, Xiamen Taylor Viscous Dampers 2011 Seismic Cable-stayed bridge uses dampers between bridge deck and Total: 8 piers to control movements caused by earthquakes. 3500 kN ± 650mm stroke Xiazhang Bridge(South) China, Xiamen Taylor Viscous Dampers 2011 Seismic Cable-stayed bridge uses dampers between bridge deck and Total: 8 piers to control movements caused by earthquakes. 3000 kN ± 450mm stroke Yuetai Fengfan Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New 33-story SRC residential project uses dampers supported Total: 18 by vertical steel frames to dissipate earthquake energy. 500 kN ± 75mm stroke Nangang ditch 3rd Bridge South Korea, Hamyang Taylor Viscous Dampers 2011 Seismic Seismic retrofit of a 530 m multi-span PSC Total: 8 using dampers. 1000 kN ± 300mm stroke Lien-Guan Nan Ganng Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New RC residential project uses dampers to dissipate Total: 8 earthquake energy. 500 kN ± 75mm stroke Chung-An Pedestrian Bridge Taiwan, Taipei Taylor Viscous Dampers 2011 Seismic New Pedestrian bridge project uses dampers to reduce wind Total: 4 movement. 500 kN ± 100mm stroke 500 kN ± 200mm stroke Taylor Viscous Dampers CHINA, Shanxi Total: 24 Pedestrian Bridge by installing TMD system to reduce Taiyuan Pedestrian Bridge 2011 Pedestrian 310KN ±100mm stroke pedestrian vibration

Taylor Viscous Dampers CHINA, Shanxi Total:6 Pedestrian Bridge by installing TMD system to reduce Taigu Pedestrian Bridge 2011 Pedestrian 231KN ±100mm stroke pedestrian vibration

Page 31 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Pinnacle Tower UK, London Taylor Viscous Dampers 2010 Wind Dampers installed in a tall building to reduce the effects of Total: 12 wind loading. The dampers allowed a reduction in structural 1800 kN ± 51mm stroke costs while improving occupant comfort. Adams Middle School USA, Redondo Beach, CA Taylor Viscous Dampers 2010 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 160 kN ± 75mm stroke Alexandra Bridge Canada, Ottawa, Ontario Taylor Viscous Dampers 2010 Pedestrian This circa 1901 railway bridge was converted to a auto and Total: 8 pedestrian traffic in the 1970's. The TMD's were found to be 1 kN ± 100mm stroke required after a spike in pedestrian traffic caused excessive vibration during the July 1st "Canada Day" festivities.

Apollo Hospital India, New Delhi Taylor Viscous Dampers 2010 Seismic Seismic retrofit of lobby block of an existing functional Total: 32 hospital to meet the revised seismic code. 32 fluid viscous 500 kN ± 100mm stroke dampers were used to dissipate seismic energy and reduce vibrations in earthquake. The work was accomplished without having to stop hospital operations. Cesar Chavez Middle School USA, Planada, CA Taylor Viscous Dampers 2010 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke Chaparral Middle School USA, Diamond Bar, CA Taylor Viscous Dampers 2010 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 160 kN ± 75mm stroke Daesung Bridge South Korea, Gapyeong Taylor Viscous Dampers 2010 Seismic Seismic retrofit of a 670 m multi-span PSC beam bridge using Total: 6 dampers. 500 kN ± 100mm stroke Duke Energy IGCC USA, Edwardsport, IN Taylor Lock up Devices 2010 Seismic Total: 14 1000 kN ± 100mm stroke East Taupo Bridge NEW ZEALAND, East Taylor Lock up Devices 2010 Seismic Taupo Total: 4 1000 kN ± 100mm stroke 750 kN ± 100mm stroke Galchun 2nd Bridge South Korea, Bonghwa Taylor Viscous Dampers 2010 Seismic Seismic retrofit of a 153 m multi-span PSC beam bridge using Total: 4 dampers. 500 kN ± 100mm stroke Gilmerton Lift Bridge USA, Chesapeake, VA Taylor Viscous Dampers 2010 Kinetic Energy of Total: 4 Moving Bridge 450 kN + 400mm stroke Kimpo Airport P3 South Korea, Seoul Taylor Viscous Dampers 2010 Seismic Retrofit of existing terminal building. Dampers installed Total: 20 across expansion joints of 3-story concrete frame. 500 kN ± 100mm stroke 1000 kN ± 100mm stroke

Page 32 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information KyungHo River 1st Bridge South Korea, Hamyang Taylor Viscous Dampers 2010 Seismic Seismic retrofit of a 530 m multi-span PSC box girder bridge Total: 8 using dampers. 750 kN ± 200mm stroke Parras Middle School USA, Redondo Beach, CA Taylor Viscous Dampers 2010 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 160 kN ± 75mm stroke Port Mann Bridge Canada, Coquitlam, BC Taylor Viscous Dampers 2010 Seismic New cable-stayed bridge uses Fluid Viscous Dampers in Total: 146 approach spans between piers and deck to dissipate seismic 2200 kN ± 50mm stroke energy. This replacement bridge (replaces aging, tied-arch 2200 kN ± 75mm stroke bridge) boast a 470 meter main span, the 2nd longest in the 2600 kN ± 418mm stroke Western Hemisphere, and a 50 meter wide deck - the widest of 2700 kN ± 50mm stroke any cable stayed bridge in the world. 3200 kN ± 100mm stroke 3500 kN ± 160mm stroke Red Hill Creek Pedestrian Bridge Canada, Hamilton, ON Taylor Viscous Dampers 2010 Seismic Located near Lake Ontario and over the QEW and an open Total: 10 creek bed, the TMD's were designed to control the effects of 1 kN ± 50mm stroke wind on the Pedestrian Bridge. Semi Bridge South Korea, Jinju Taylor Viscous Dampers 2010 Seismic Seismic retrofit of a 180 m multi-span PSC beam bridge using Total: 6 dampers. 750 kN ± 100mm stroke Xinjiang Guozili Bridge China Taylor Viscous Dampers 2010 Seismic Twin towers cable-stayed main span 330m, uses dampers to Total: 4 protect the structure during earthquakes. 1000 kN ± 400mm stroke Xinjiang Guozili Bridge China Taylor Viscous Dampers 2010 Seismic Twin towers cable-stayed main span 330m, uses dampers to Total: 4 protect the structure during earthquakes. 1191 kN ± 500mm stroke TSMC Fab #14, P4 Taiwan, Hsin Chu City Taylor Viscous Dampers 2010 Seismic New semiconductor fabrication plant uses dampers to Total: 20 dissipate seismic energy and reduce vibrations in earthquake. 2000 kN ± 75mm stroke Linyi Culture Square China, Linyi Taylor Viscous Dampers 2010 Wind New construction 20 Tuned Mass Dampers for the reduction Total : 40 of wind vibrations in large span roof truss section. TMD Systems Sheng De Fu Construction: Fu-Yu Taiwan, Taipei Taylor Viscous Dampers 2010 Seismic New RC 15-story residential project uses dampers to dissipate Total: 4 earthquake energy. 150 kN ± 25mm stroke Taoto Tapyuna 18th Taiwan, Taoyuan Taylor Viscous Dampers 2010 Seismic New 19-story RC residential project uses dampers to dissipate Total: 56 energy and reduce earthquake vibrations. 500 kN ± 75mm stroke Hong-Chiao Yong-Kang Taiwan, Taipei Taylor Viscous Dampers 2010 Seismic New RC residential project uses dampers to dissipate energy. Total: 8 500 kN ± 75mm stroke Barwon Heads Bridge Australia, Victoria Taylor Fluid Dampers 2010 Seismic Lock-up devices used to limit bridge deck displacements for a Total: 10 new highway bridge with timber piers. 405 kN ± 50mm stroke

Page 33 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Meguro Gajoen Extension Project Japan, Tokyo Taylor Fluid Dampers 2010 Seismic New construction, 16-story steel and concrete frame Total: 72 office/hotel/parking structure uses dampers to dissipate 1000 kN ± 50mm stroke earthquake energy. 1500 kN ± 50mm stroke 2000 kN ± 50mm stroke Kasumigaseki 3 Chome Project Japan, Tokyo Taylor Fluid Dampers 2010 Seismic New construction, 17-story steel frame office/parking Total: 12 structure uses dampers to dissipate earthquake energy. 1000 kN ± 50mm stroke 1500 kN ± 50mm stroke Taylor Fluid Dampers Total:4 Cable-stayed bridge uses dampers between bridge deck and Chongqing Changshou Bridge China , Chongqing 2010 Seismic 1500KN ±300mm stroke piers to control movements caused by earthquakes.

Kindom Jing-Ping Project Taiwan, Taipei Taylor Viscous Dampers 2009 Seismic New 25-story SRC residential project, uses a combination of Total: 22 viscous dampers and buckling restrained braces to reduce 1000 kN ± 100mm stroke vibrations caused by earthquake. 250 West 55th Street USA, New York, NY Taylor Fluid Dampers 2009 Wind Custom high capacity metal bellows dampers used as part of Total: 7 an outrigger system in a new 39-story all glass exterior office 1690 kN ± 100mm stroke building to reduce wind motion. WRCT Project USA, Boone County, KY Taylor Fluid Dampers 2009 Seismic Devices used to provide dynamic force transfer across thermal Total: 2 expansion joint of the supporting structure for this elevated 750 kN ± 100mm stroke Western Regional Conveyance Tunnel. U.S. Dept. of Interior Bureau of USA, Provo, UT Taylor Fluid Dampers 2009 Seismic Retrofit of an office complex. Dampers and lock-up devices Reclamation - Utah Projects Office Total: 9 used in diagonal braces to dissipate earthquake energy and Complex 445 kN ± 100mm stroke reduce displacement. 245 kN ± 75mm stroke LAX Theme Building USA, Los Angeles, CA Taylor Fluid Dampers 2009 Seismic Retrofit of an elevated restaurant supported by four curved Total: 8 legs. Dampers used as part of a mass damper system to 555 kN ± 150mm stroke control movement of the mass block during an earthquake.

100 International Drive - USA, East Hartford, CT Taylor Fluid Dampers 2009 Seismic Single-story steel framed warehouse building with plan Steel Warehouse Total: 2 dimensions of 676’ x 450’. Dampers transfer loads across 330 kN ± 100mm stroke expansion joint at diaphragm chord trusses. T.F. Green Airport Parking Garage USA, Providence, RI Taylor Fluid Dampers 2009 Seismic Located in Warwick, near Providence, RI, this airport parking Total: 64 garage uses dampers to transfer loads across expansion joints, 135 kN ± 32mm stroke thereby reducing the large seismic expansion joint/gap 270 kN ± 75mm stroke requirements. Aircraft Hanger USA, Hawthorne, CA Taylor Fluid Dampers 2009 Seismic Voluntary seismic upgrade of an aircraft hangar building Total: 160 using dampers in double-diagonal braces to provide seismic 900 kN ± 100mm stroke energy dissipation. 865 Market Street - San Francisco USA, San Francisco, CA Taylor Fluid Dampers 2009 Seismic Voluntary Seismic upgrade of existing multi-story Nordstrom Centre Total: 50 Store in a San Francisco downtown shopping center mall. 2000 kN ± 125mm stroke Dampers in diagonal braces provide seismic energy 2000 kN ± 165mm stroke dissipation.

Page 34 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information 3300 Hyland Ave. – Abraxis Biosciences USA, Costa Mesa, CA Taylor Fluid Dampers 2009 Seismic Seismic upgrade of 3-story existing structure containing Total: 44 offices on the first and third floors and a state-of-the-art 1000 kN ± 100mm stroke upgraded laboratory on the second floor. Dampers in double- diagonals provide seismic energy dissipation. IETMC USA, Fontana, CA Taylor Fluid Dampers 2009 Seismic New Caltrans District 8 Inland Empire Transportation Total: 8 Management Center with 24/7 Emergency traffic response 1500 kN ± 610mm stroke and management facilities uses rubber isolators and Taylor dampers to meet immediate occupancy criteria in this 2-story steel structure. Todai-ji Culture Center Japan, Nara Taylor Viscous Dampers 2009 Seismic New museum in Todai-ji Temple, a World Heritage and Total: 4 National Treasure, uses dampers in special floor isolation 250 kN ± 350mm stroke system to dissipate seismic energy. 80kN +/- 350mm stroke Dubai Racetrack Stadium United Arab Emirates, Taylor Fluid Dampers 2009 Wind New stadium utilizing 36 Tuned Mass Dampers for the Dubai Total: 108 reduction of wind vibrations in large cantilevered roof truss 885 kN ± 50mm stroke sections. 1280 kN ± 50mm stroke 1370 kN ± 50mm stroke Meixihe Bridge China, Chongqing Taylor Fluid Dampers 2009 Seismic Retrofit of a 1990 vintage suspension bridge with a 222m main Total: 4 span. Dampers used to reduce displacements caused by 1750 kN ± 250mm stroke earthquakes. Nanping Mingjian Bridge China, Fujian Taylor Fluid Dampers 2009 Seismic Cable-stayed bridge uses dampers between bridge deck and Total: 4 piers to control movements caused by earthquakes. 1400 kN ± 500mm stroke Ningbo Yongjiang Bridge China, Ningbo Taylor Fluid Dampers 2009 Seismic Cable-stayed bridge uses dampers between bridge deck and Total: 8 piers to control movements caused by earthquakes. 1800 kN ± 550mm stroke Nihonbashi Nomura Project Japan, Tokyo Taylor Fluid Dampers 2009 Seismic New construction, 21-story steel frame office/commerce Total: 52 facility/parking uses dampers to dissipate earthquake energy. 1100 kN ± 50mm stroke 1500 kN ± 50mm stroke 2000 kN ± 50mm stroke Hydra Waves Mexico, Mazatlan Taylor Fluid Dampers 2009 Seismic New structure use dampers to absorb earthquake energy and Total: 18 reduce deflection and stress. 680 kN ± 50mm stroke Tauranga Harbour Link Bridge New Zealand, Tauranga Taylor Fluid Dampers 2009 Seismic New four lane highway bridge use Lock-Up Devices with force Total: 21 limiting devices to control bridge deck movement during 980 kN ± 175mm stroke seismic events. 1470 kN ± 175mm stroke 1750 kN ± 225mm stroke ASE I – Mihai Eminescu Project Romania, Bucharest Taylor Fluid Dampers 2009 Seismic Retrofit of a historic building with dampers in diagonal braces Total: 142 to provide seismic energy dissipation. 1000 kN ± 100mm stroke 100 kN ± 100mm stroke

Page 35 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information TSMC Fab #12 P5 Taiwan, Hsin Chu City Taylor Fluid Dampers 2009 Seismic Retrofit of a semiconductor processing plant uses dampers to Total: 6 dissipate seismic energy and micro-vibrations. 2000 kN ± 75mm stroke Uni-President B8 Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Known as Taipei Hsin-Yi Project, this new 22-story reinforced Total: 336 concrete building uses dampers in chevron braces to dissipate 600 kN ± 75mm stroke seismic energy. FDS Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers installed in RC supporting wall in a new reinforced Total: 6 concrete building. 500 kN ± 75mm stroke Farglory H61 Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers installed in RC supporting wall in a new reinforced Total: 12 concrete building. 500 kN ± 75mm stroke Farglory H63 Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers used in chevron bracing elements in a new 15-story Total: 52 reinforced concrete building. 500kN ± 75mm stroke Farglory H65 Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers used in chevron bracing elements in a new 14-story Total: 46 reinforced concrete building. 500kN ± 75mm stroke Farglory H69 Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers installed in RC supporting wall in a new 14-story Total: 54 reinforced concrete building. 500 kN ± 75mm stroke Farglory H70 Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic New 13-story steel reinforced concrete residential building use Total: 20 dampers in chevron braces to dissipate seismic energy. 500 kN ± 75mm stroke Ruentex Wan-Shi Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers used as part of a base isolation system for a new Total: 8 building. Dampers provide energy dissipation and reduce 2000 kN ± 500mm stroke displacement required for the isolation system. Huaku Academia Sinica Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers used in chevron bracing elements in a new 15-story Total: 10 reinforced concrete building. 100 kN ± 75mm stroke Sunrise Golf and Country Club Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers used in chevron bracing elements to dissipate Total: 104 earthquake energy in a new 33-story steel frame residential 500 kN ± 75mm stroke building. Jee Tai Buildings Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Retrofit of multiple reinforced concrete buildings uses Total: 20 dampers for seismic energy dissipation. 300 kN ± 59mm stroke 500 kN ± 75mm stroke 750 kN ± 75mm stroke Huaku Ji-Lin Project A Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers used in chevron bracing elements in a new Total: 8 reinforced concrete building. 1000 kN ± 75mm stroke Jiun-Yi Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers installed in RC supporting wall in a new 15-story Total: 10 reinforced concrete building to dissipate seismic energy. 500 kN ± 75mm stroke

Page 36 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information KwanFon Project Taiwan, Taipei Taylor Fluid Dampers 2009 Seismic Dampers installed in RC supporting wall in a new reinforced Total: 4 concrete building. 500 kN ± 75mm stroke Aratsu Bridge Japan, Fukuoka Taylor Fluid Dampers 2009 Seismic Retrofit of cable-stayed bridge, length is 345m, uses dampers Total: 4 between pier and deck to control seismic movements. 2900 kN ± 180mm stroke 2300 kN ± 180mm stroke Nagoya-Port Government Office Japan, Nagoya Taylor Fluid Dampers 2009 Seismic Retrofit of 15,264 square meter, 9-story reinforced concrete Main Building Total: 20 building. Dampers used in diagonal braces to dissipate 500 kN ± 50mm stroke earthquake energy. Jusan 1st Bridge South Korea, Hwasun Taylor Fluid Dampers 2009 Seismic Seismic retrofit of a 240 m multi-span PSC beam bridge using Total: 8 dampers. 500 kN ± 200mm stroke Jusan 2nd Bridge South Korea, Hwasun Taylor Fluid Dampers 2009 Seismic Seismic retrofit of a 180 m multi-span PSC beam bridge using Total: 4 dampers. 500 kN ± 200mm stroke Goko Bridge South Korea, Yeongi Taylor Fluid Dampers 2009 Seismic Seismic retrofit of a 210 m multi-span PSC beam bridge using Total: 4 dampers. 500 kN ± 100mm stroke Namhae Grand Bridge South Korea, Namhae Taylor Fluid Dampers 2009 Seismic Seismic retrofit of a 660 m (main span 404m) suspension Total: 12 bridge using dampers. 500 kN ± 200mm stroke Eommi 2nd Bridge South Korea, Gwangju Taylor Fluid Dampers 2009 Seismic Seismic retrofit of a 135 m multi-span PSC box girder bridge Total: 4 using dampers. 400 kN ± 100mm stroke Kimpo Airport Phase II South Korea, Seoul Korea, Taylor Fluid Dampers 2009 Seismic Retrofit of existing terminal building. Dampers installed Hongsung Total: 8 across expansion joints of 3-story concrete frame building to 500 kN ± 100mm stroke dissipate seismic energy. Hongsungwasun Bridge South Korea, Hongsung Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 300 m multi-span steel box girder and Total: 4 PSC beam bridge using dampers. 850 kN ± 120mm stroke Sojung Grand Bridge South Korea, Yoengi Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 500 m multi-span steel box girder bridge Total: 6 using dampers. 850 kN ± 100mm stroke Watan Bridge South Korea, Yeonggwang Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 380 m multi-span steel box girder bridge Total: 4 using dampers. 850 kN ± 100mm stroke Namgang Bridge South Korea, Hamyang Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 240 m multi-span steel box girder bridge Total: 2 using dampers. 850 kN ± 100mm stroke Ansungchun Bridge South Korea, Ansun Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 450 m multi-span PSC beam bridge using Total: 10 dampers. 1000 kN ± 100mm stroke

Page 37 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information California Dept. of Transportation - USA, Oakland, CA Taylor Fluid Dampers 2008 Seismic Retrofit of 15-story steel moment frame structure built in District 4 Headquarters Total: 231 1991. Dampers used in diagonal braces to dissipate seismic 1000 kN ± 125mm stroke energy. 2000 kN ± 125mm stroke 3000 kN ± 125mm stroke Atlanta Botanical Garden USA, Atlanta, GA Taylor Fluid Dampers 2008 Pedestrian Custom pre-tensioned spring loaded dampers used to control Total: 4 pedestrian induced vibrations in an elevated walkway located 11 kN ± 75mm stroke in the tree canopy. Citycenter Project Pedestrian Bridge USA, Las Vegas, NV Taylor Fluid Dampers 2008 Pedestrian Group of three new pedestrian bridges utilize Taylor tuned Total: 6 TMD Systems mass dampers to reduce pedestrian-induced vibrations.

Roosevelt Island Lift Bridge USA, New York, NY Taylor Fluid Dampers 2008 Kinetic Energy of Retrofit of a vertical lift bridge for protection from runaway Total: 8 Moving Bridge motors and brake failures. 267 kN 560mm stroke Solomon R. Guggenheim Museum USA, New York, NY Taylor Fluid Dampers 2008 Wind & Traffic Retrofit of world-famous Frank Lloyd Wright Building first Total: 54 Vibration opened in 1959. First building application of hermetic metal 20 kN ± 30mm stroke bellows dampers, providing broad-band vibration control of concrete outer walls. Dampers installed in radial braces on top floor. Pengxihe River Bridge China, Changqing Taylor Fluid Dampers 2008 Seismic 632m main span cable-stayed bridge uses dampers between Total: 4 the bridge deck and piers to control seismic/wind movement. 1600 kN ± 200mm stroke Jiangjin Guanyinyan Bridge China, Changqing Taylor Fluid Dampers 2008 Seismic Major cable-stayed bridge uses dampers to reduce Total: 4 displacement caused by earthquakes. 1200 kN ± 200mm stroke Yuzui Yangtze River Bridge China, Changqing Taylor Fluid Dampers 2008 Seismic 616m main span cable-stayed bridge uses dampers between Total: 4 tower and deck to allow free thermal movement and control 1500 kN ± 550mm stroke seismic movements. Hangzhou Jiangdong Bridge I China, Hangzhou Taylor Fluid Dampers 2008 Seismic 260m main span suspension bridge uses dampers between the Total: 4 bridge deck and piers to control seismic/wind movement. 2000 kN ± 300mm stroke Hangzhou Jiangdong Bridge II China, Hangzhou Taylor Fluid Dampers 2008 Seismic 260m main span suspension bridge uses dampers between the Total: 4 bridge deck and piers to control seismic/wind movement. 2000 kN ± 300mm stroke Jiangyin Bridge Maintain Vehicle China, Jiangyin Taylor Fluid Dampers 2008 Bridge Vibration 8 dampers for two bridge inspection vehicles (inspection Total: 8 travelers). 8.9 kN ± 25mm stroke Jingtang Bridge China, Zhejiang Taylor Fluid Dampers 2008 Seismic & Wind World’s 9th longest cable-stayed bridge uses dampers on the Total: 4 main span to control seismic/wind movements. 2750 kN ± 350mm stroke Shanghai Hangar China, Shanghai Taylor Fluid Dampers 2008 Seismic 156.68m Span Hanger, new construction. 8 dampers in Total: 8 chevron braces to dissipate seismic energy. 1300 kN ± 100mm stroke

Page 38 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Shanxi Xianshen River Bridge China, Shangxi, Jinyang Taylor Fluid Dampers 2008 Seismic 150m height single tower cable-stayed bridge uses dampers Total: 9 between the bridge deck and piers to control seismic/wind 1500 kN ± 300mm stroke movement. Suramadu Bridge Indonesia, Surabaya Taylor Fluid Dampers 2008 Seismic 445m main span cable-stayed bridge uses dampers with end of Madura Total: 4 travel bumpers between the bridge deck and piers to control 2400 kN ± 450mm stroke seismic/wind movement. Steel Mill Project Canada, Tracy, QC Taylor Lock-Up Devices 2008 Seismic Expansion of an existing steel structure. Lock Up Devices used Total: 8 to control seismic movement while allowing free thermal 200 kN ± 75mm stroke movement. Mizunami Transformer Station Tower Japan, Gifu Taylor Fluid Dampers 2008 Seismic Seismic retrofit of wireless station steel tower. Dampers used Total: 4 16.5 in a TMD system to dissipate seismic energy. All stainless steel kN ± 200mm stroke dampers. Ooigawa Transformer Station Tower Japan, Shizuoka Taylor Fluid Dampers 2008 Seismic Seismic retrofit of wireless station steel tower. Dampers used Total: 4 16.5 in a TMD system to dissipate seismic energy. All stainless steel kN ± 200mm stroke dampers. Taketoyo Thermal Power Station Tower Japan, Aichi Taylor Fluid Dampers 2008 Seismic Seismic retrofit of wireless station steel tower. Dampers used Total: 4 in a TMD system to dissipate seismic energy. All stainless steel 16.5 kN ± 200mm stroke dampers. Kimpo Airport Phase I South Korea, Seoul Taylor Fluid Dampers 2008 Seismic Retrofit of an existing building. Dampers installed across Total: 4 expansion joints of 3-story concrete frame building to dissipate 500 kN ± 100mm stroke seismic energy for Korea Airports Corporation. Gang Dong Grand Bridge South Korea, Seoul Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 1126 meter multi-span PSC box girder Total: 12 bridge with dampers the Korea Expressway Corporation. 2000 kN ± 300mm stroke Kyung Ho 2nd Bridge South Korea, Sancheong Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 340 meter multi-span PSC Box bridge Total: 4 with dampers for the Korea Expressway Corporation. 750 kN ± 250mm stroke Kyung Ho 6th Bridge South Korea, Sancheong Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 630 meter multi-span PSC Box bridge Total: 8 with dampers for the Korea Expressway Corporation. 1500 kN ± 200mm stroke Hang Jyung Bridge South Korea, Sancheong Taylor Fluid Dampers 2008 Seismic Seismic retrofit of a 630 meter multi-span PSC Box bridge Total: 10 with dampers for the Korea Expressway Corporation. 1500 kN ± 250mm stroke Marena Project Mexico, Acapulco Taylor Fluid Dampers 2008 Seismic New resort/hotel/condominium complex uses dampers to Total: 52 dissipate seismic energy. 600 kN ± 50mm stroke 570 kN ± 50mm stroke Academy for Economical Studies II Romania, Bucharest Taylor Fluid Dampers 2008 Seismic Retrofit of a building with 80 isolation bearings and 18 Project Total: 18 dampers. 1500 kN ± 500mm stroke Academy for Economical Studies - Romania, Bucharest Taylor Fluid Dampers 2008 Seismic Retrofit of a building with dampers located at the roof to Sports Complex Total: 6 dissipate earthquake energy. 300 kN ± 75mm stroke

Page 39 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information TSMC Fab #12 P4 Taiwan, Hsin Chu City Taylor Fluid Dampers 2008 Seismic Retrofit of a semiconductor processing plant uses dampers to Total: 18 dissipate seismic energy and micro-vibrations. 2000 kN ± 75mm stroke Criminal Investigation Bureau Taichung Taiwan, Taichung Taylor Fluid Dampers 2008 Seismic 15-story steel braced frame building uses a combination of Total: 4 BRBs and dampers in diagonal braces for seismic energy 392 kN ± 50mm stroke dissipation. 784 kN ± 75mm stroke Hung-Feng Nei-Hu Residence Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic New 5-story residential building uses dampers in reinforced Total: 12 concrete supporting walls to dissipate seismic energy 500 kN ± 75mm stroke Fu-Shi Tu-Cheng Project Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic New 12-story residential building uses dampers in reinforced Total: 24 concrete supporting walls to dissipate seismic energy. 500 kN ± 75mm stroke Ya-Ting Chung-Ho Project Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic New 14-story residential building uses dampers in reinforced Total: 16 concrete supporting walls to dissipate seismic energy. 500 kN ± 75mm stroke Mei-Feng Residential Building Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic New 16- story steel residential building uses dampers in double Total: 32 A-shape frames to dissipate seismic energy. 1000 kN ± 60mm stroke Farglory Fortuna H62 Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic Two new 16-story steel reinforced concrete residential Total: 80 building use dampers in double A-shape frames to dissipate 500 kN ± 75mm stroke seismic energy. Farglory Twin-Towers H40 Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic Two new 25-story steel reinforced concrete residential Total: 162 building use dampers in double A-shape frames to dissipate 500 kN ± 60mm stroke seismic energy. 800 kN ± 75mm stroke Hung Poo Construction/ KIMZO New Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic New 19-story residential building uses dampers in reinforced Trump Total: 24 concrete supporting walls to dissipate seismic energy. 1000 kN ± 100mm stroke Kindom Kui-Lin Project Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic New 19-story steel reinforced concrete residential building Total: 24 with dampers to dissipation seismic energy. 1000 kN ± 100mm stroke Uni-President Taipei Transfer Post (A3) Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic New 31-story steel structure with dampers to improve Total: 124 structural performances. Dampers are installed in diagonal 600 kN ± 75mm stroke braces and A-shape supporting frames. 600 kN ± 100mm stroke Kelti Hsin-Yi Building Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic New 14-story steel office building in Taipei Project. Viscous Total: 80 dampers are used for energy dissipation. Dampers are 1400 kN ± 100mm stroke installed in diagonal braces. 1500 kN ± 100mm stroke Chiyoda Project Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic 16-story reinforced concrete moment frame building uses Total: 16 dampers in double A-shape frames to dissipate seismic energy. 980 kN ± 60mm stroke

Page 40 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Twin Oak Garden Project Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic 16-story reinforced concrete moment frame building uses Total: 32 dampers in double A-shape frames to dissipate seismic energy. 980 kN ± 60mm stroke Far Glory Twin Towers Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic Two 24-story residential buildings use dampers in double A- Total: 162 shape frames to dissipate seismic energy. 490 kN ± 60mm stroke 785 kN ± 75mm stroke Mei-Feng Residential Building Taiwan, Taipei Taylor Fluid Dampers 2008 Seismic 19-story residential building uses dampers in A-shape frames Total: 32 to dissipate seismic energy. 980 kN ± 60mm stroke Mills Peninsula Hospital USA, Burlingame, CA Taylor Fluid Dampers 2007-2008 Seismic 450,000 square foot replacement hospital for Peninsula Total: 32 Medical Center with 243 beds. Dampers used with base 1225 kN ± 762mm stroke isolation system. Taylor Fluid Dampers China/Hubei Total:4 The main span 926m double tower cable-stayed bridge, Edong Bridge 2008 Seismic 1000KN ±600mm stroke damper for energy-absorbing shock absorption.

Cumberland River Pedestrian Bridge USA, Nashville, TN Taylor Fluid Dampers 2007 Pedestrian Five TMD Systems used to control lateral and vertical Total: 5 vibrations caused by pedestrian traffic. TMD Systems KDDI Tama Fourth Network Center 1st Japan, Tokyo Taylor Fluid Dampers 2007 Seismic 6-story, 24,000 square meter telephone network center is base Station Total: 28 isolated with dampers to reduce seismic movement and 1450 kN ± 610mm stroke provide energy dissipation. Tres Mares Residences Mexico, Puerto Vallarta Taylor Fluid Dampers 2007 Seismic 27-story, 40,200 square meter condominium building with Total: 30 concrete columns and steel beams. Dampers used in diagonal 900 kN ± 100mm stroke braces for seismic energy dissipation. 1450 kN ± 100mm stroke TSMC Fab #14 Taiwan, Taipei Taylor Fluid Dampers 2007 Seismic Retrofit of a semiconductor processing plant uses damper to Total: 20 dissipate seismic energy and micro-vibrations. 2000 kN ± 75mm stroke Dong-Teng Project Taiwan, Taipei Taylor Fluid Dampers 2007 Seismic 15-story steel braced frame residential building uses dampers Total: 32 in A-frames to dissipate seismic energy. 490 kN ± 75mm stroke Jin Nam 3rd Bridge South Korea, Mungyeong Taylor Fluid Dampers 2007 Seismic Seismic retrofit of a 680 meter multi-span steel box girder and Total: 10 PSC Beam bridge with dampers for the Ministry of Land 850 kN ± 100mm stroke Transport and Maritime Affairs. New Yang Soo Bridge South Korea, Yangpyeong Taylor Fluid Dampers 2007 Seismic Seismic retrofit of a 2180 meter multi-span steel box girder Total: 34 and PSC Beam bridge with dampers for the Ministry of Land 2000 kN ± 100mm stroke Transport and Maritime Affairs. 850 kN ± 100mm stroke Gang Hwa Grand Bridge South Korea, Ganghwa Taylor Fluid Dampers 2007 Seismic Seismic retrofit of a 780 meter multi-span steel box girder Total: 8 bridge with dampers for the Ministry of Land Transport and 2000 kN ± 120mm stroke Maritime Affairs.

Page 41 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Clerkenwell Road Bridge UK, London Taylor Fluid Dampers 2007 Seismic Strengthening Project – Lock-up devices used to control Total: 2 seismic movement while allowing free thermal movement. 582 kN ± 100mm stroke Coker Structure Venezuela, Barcelona Taylor Fluid Dampers 2007 Seismic Dampers used to reduce vibrations caused by a chemical Total: 26 reaction in a large vessel. 50 kN ± 150mm stroke 131 South Rodeo Drive USA, Beverly Hills, CA Taylor Fluid Dampers 2007 Seismic Voluntary seismic retrofit uses dampers in diagonal bracing Total: 18 elements for seismic energy dissipation. 2000 kN ±75mm stroke Don Pedro High School USA, Groveland, CA Taylor Fluid Dampers 2007 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke Tioga High School USA, Groveland, CA Taylor Fluid Dampers 2007 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke Sutter Gould Medical Office Building USA, Modesto, CA Taylor Fluid Dampers 2007 Seismic 4-story, 13,400 square meter medical office building. Steel Total: 40 construction with dampers in diagonal bracing elements for 712 kN ± 75mm stroke seismic energy dissipation. Beijing 7 Star Morgan Plaza Hotel China, Beijing Taylor Fluid Dampers 2007 Seismic & Wind New 40-story building uses a combination of fluid dampers Total: 108 and fluid visco-elastic dampers to reduce seismic and wind 1000 kN ± 40mm stroke vibrations. 1000 kN ± 100mm stroke 1500 kN ± 150mm stroke Stamford Building New Zealand, Auckland Taylor Fluid Dampers 2007 Wind Residential tower uses dampers in a three-mass TMD system Total: 12 to reduce motion caused by wind for comfort level 25 kN ± 150mm stroke improvements. Loma Linda University Medical Center USA, Loma Linda, CA Taylor Fluid Dampers 2007 Seismic Seismic upgrade of hospital structure uses long fluid viscous Total: 10 dampers in diagonal braces of Buildings A&C. 890 kN ± 100mm stroke Whalley Reservoir Canada, Surrey, BC Taylor Fluid Dampers 2007 Seismic Dampers surround this in-ground reservoir to control seismic Total: 17 drift of concrete lid. 1000 kN ± 125mm stroke Jiangyin Bridge China, Jiangsu Province Taylor Fluid Dampers 2007 Seismic World’s 5th longest suspension bridge uses dampers mounted Total: 4 vertically at expansion joints to control traffic vibrations. 1000 kN ± 1000mm stroke Xihoumen Bridge China, Zhejiang Province Taylor Fluid Dampers 2007 Seismic World’s 2nd longest suspension bridge located at Zhoushan Total: 4 Island uses dampers in the longitudinal direction to dissipate 1000 kN ± 1100mm stroke seismic energy. Cal Poly Pomona Library USA, Pomona, CA Taylor Fluid Dampers 2007 Seismic Seismic retrofit of college library building uses long fluid Total: 12 viscous dampers in diagonal braces. 1335 kN ± 178mm stroke Doutor Coffee Nagoya Project Japan, Nagoya City Taylor Fluid Dampers 2007 Seismic New 9-story office building (2, 096 square meters) uses Total: 2 dampers for seismic energy dissipation. 3000 kN ± 50mm stroke

Page 42 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Saitama Citizen Medical Center Japan, Saitama City Taylor Fluid Dampers 2007 Seismic New 6-story hospital (29, 320 square meters) uses dampers Total: 12 with base isolation system for seismic energy dissipation. 1450 kN ± 610mm stroke Minatoku Office Building Japan, Tokyo-Minato-ku Taylor Fluid Dampers 2007 New 13-story office building (17, 200 square meters) uses (Mita 3 Chome project) Total: 32 dampers in diagonal braces for seismic energy dissipation. 785 kN ± 100mm stroke Starwood Hotel - Sage Hospitality USA, Portland, OR Taylor Fluid Dampers 2007 Seismic Remodel and seismic retrofit/upgrade of Meir and Frank Total: 212 Building, floors 6-14. Project uses dampers in chevron braces. 445 kN ± 100mm stroke 670 kN ± 100mm stroke 890 kN ± 100mm stroke Leona Drive Residence USA, Beverly Hills, CA Taylor Fluid Dampers 2007 Floor Vibrations New residence with cantilevers that requires damping for Total: 3 comfort level improvements from floor vibrations. 22 kN ± 25mm stroke Shen-Mao Garter Castle Residential Taiwan, Taipei Taylor Fluid Dampers 2007 Seismic New 14-story R/C residential building uses 32 dampers in R/C Building Total: 32 supporting walls and bracing for energy dissipation. 1000 kN ± 50mm stroke Nordstrom – Santa Barbara Paseo USA, Santa Barbara, CA Taylor Fluid Dampers 2007 Seismic Store remodel includes structural seismic upgrade with Nuevo Store # 344 Total: 38 dampers used in chevron braces for seismic energy dissipation. 890 kN ± 100mm stroke 670 kN ± 100mm stroke Abe Transformer Station Tower Japan, Shizuoka Prefecture Taylor Fluid Dampers 2007 Seismic Seismic retrofit of wireless station steel tower. Dampers used Total: 4 in TMD system to dissipate seismic energy. 16 kN + 200mm stroke Seattle Central Link Light Rail USA, Seattle, WA Taylor Fluid Dampers 2007 Seismic 1.7 mile Extension of light rail line to SEA-TAC Int’l airport, Total: 6 uses shock transmission units to control seismic 2000 kN ± 76mm stroke movement/allow free thermal movement. 2558 kN ± 76mm stroke Port of Seattle South 160th St. Loop USA, Seattle, WA Taylor Fluid Dampers 2007 Seismic New light rail line at SEA-TAC Int’l airport utilizes shock Ramp Light Rail Total: 24 transmission units to control seismic movement while allowing 1000 kN ± 100mm stroke free thermal movement. 2000 kN ± 76mm stroke 2558 kN ± 76mm stroke Lian-Yun Tai-An Residence Taiwan, Taipei Taylor Fluid Dampers 2007 Seismic New 12-story R/C residential building uses 6 dampers in first Total: 6 floor to dissipate seismic energy. 1000 kN ± 100mm stroke Huaku Wen-De Residence Taiwan, Taipei Taylor Fluid Dampers 2007 Seismic New 14-story R/C residential building uses 24 dampers for Total: 24 seismic energy dissipation. 500 kN ± 60mm stroke Huaku Ming-Chiuan Residence Taiwan, Taipei Taylor Fluid Dampers 2007 Seismic New 15 story R/C residential building uses 48 dampers for Total: 48 seismic energy dissipation. 1000 kN ± 60mm stroke

Page 43 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Kindom Millennium Celebrity Taiwan, Taipei Taylor Fluid Dampers 2007 Seismic New 27-story steel/concrete residential building located on soft Total: 12 soil of old volcano valley uses dampers for earthquake energy 500 kN ± 50mm stroke dissipation. SR 62 Bridge over Wabash River USA, Posey County, IN Taylor Fluid Dampers 2007 Seismic Indiana DOT Bridge over Wabash River to White County, Total: 80 Illinois uses Lock-up Devices to control seismic movement 290 kN ± 100mm stroke while allowing free thermal movement. 470 kN ± 100mm stroke Pomeroy-Mason Bridge USA, Grove City, OH Taylor Fluid Dampers 2007 Wind/Rain New cable-stayed bridge. Dampers attached to cable stays to Total: 96 reduce motion induced by a combination of wind and rain. 23 kN ± 75mm stroke Sutong Changjiang River Bridge China, Jiangsu Province Taylor Fluid Dampers 2007 Seismic & Wind World’s longest cable-stayed bridge uses special spring Total: 8 dampers on the main span to control seismic/wind movements. 6580 kN ± 850mm stroke Longhua Songhua River Bridge China, Songyvan, Jilin Taylor Fluid Dampers 2007 Seismic New 7-span reinforced concrete continuous beam bridge uses Province Total: 16 Lock-Up Devices to control seismic movement while allowing 1800 kN ± 140mm stroke free thermal movement. Rainbow Bridge (Nei-Hu Suspension Taiwan, Taipei Taylor Fluid Dampers 2007 Seismic New steel arch-suspension bridge uses dampers for Bridge) Total: 4 earthquake energy dissipation. 500 kN ± 100mm stroke Nueva Palmira Wharf Uruguay, Montevideo Taylor Fluid Dampers 2007 Wind & Berthing New multi-modal harbor port terminal. Dampers used for Total: 6 Loads wind/impact load protection of wharf structure with pile 900 kN ± 100mm stroke foundations. Tan Zu/Tzu Chi Hospital Taiwan, Taichung City Taylor Fluid Dampers 2007 Seismic New construction of a 14-story, 145k m2 hospital. Dampers Total: 88 used to add energy dissipation to the base isolation system. 1716 kN ± 750mm stroke Roslyn Bridge Replacement for USA, Roslyn, NY Taylor Fluid Dampers 2007 Seismic Replacement segmental concrete overpass structure uses fluid Route 25A over Hempstead Harbor Total: 8 viscous dampers for earthquake energy dissipation. 2000 kN ± 280mm stroke Seattle Central Link Light Rail Section USA, Seattle, WA Taylor Fluid Dampers 2007 Seismic New light rail line utilizes shock transmission units to control C755 Total: 34 seismic movement while allowing free thermal movement. 1000 kN ± 100mm stroke 2000 kN ± 76mm stroke 2558 kN ± 76mm stroke Macy’s Store - Meier & Frank Building USA, Portland, OR Taylor Fluid Dampers 2006-2007 Seismic Remodel and seismic retrofit/upgrade of Meier and Frank Remodel Total: 160 Building floors 1-5. Project uses dampers in chevron braces. 890 kN ± 100mm stroke 1112 kN ± 100mm stroke 1335 kN ± 100mm stroke 1780 kN ± 100mm stroke Naval Hospital Bremerton USA, Bremerton, WA Taylor Fluid Dampers 2006-2007 Seismic Seismic upgrade of 1960’s era, 9-story, 2,500 square meter Total: 88 hospital utilizes dampers in diagonal braces to reduce drift 890 kN ± 100mm stroke and dissipate seismic energy.

Page 44 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information JR Tokai Shin Yokohama Station Japan, Tokyo Taylor Fluid Dampers 2006-2007 Seismic New 19-story 100,000 square meter steel train Total: 377 station/office/hotel building uses dampers in diagonal braces to 500 kN ± 50mm stroke dissipate seismic energy. 1000 kN ± 50mm stroke 1500 kN ± 50mm stroke Rock Church (Nehemiah Project) USA, San Diego, CA Taylor Fluid Dampers 2006 Pedestrian Two 10,000 Lbs TMD systems used to dampen vibrations on Total: 2 Dancing the main cantilevered balcony in the sanctuary. TMD Systems Vibration Guangzhou Stadium China, Guangzhou Taylor Fluid Dampers 2006 Seismic New Stadium uses dampers in stadium substructure framing Total: 12 to provide seismic energy dissipation. 1500 kN ± 100mm stroke Nordstrom – Tyler Mall Store #35 USA, Riverside, CA Taylor Fluid Dampers 2006 Seismic Store remodel includes structural seismic upgrade with Total: 32 dampers used in chevron braces for seismic energy dissipation. 980 kN ± 100mm stroke Nordstrom – South Bay Galleria USA, Redondo Beach, CA Taylor Fluid Dampers 2006 Seismic Store remodel includes structural seismic upgrade with Total: 16 dampers used in chevron braces for seismic energy dissipation. 890 kN ± 15mm stroke Los Angeles California Temple USA, Los Angeles, CA Taylor Fluid Dampers 2006 Seismic Voluntary Seismic upgrade of church steeple (spire) with Total: 9 dampers used in special apparatus for seismic energy 360 kN +175/-25mm stroke dissipation. Jorge Chavez International Airport Peru, Lima Taylor Fluid Dampers 2006 Seismic Retrofit of a 10-story R/C central tower structure. Dampers Central Tower Total: 42 are used in chevron braces to provide seismic energy 490 kN ± 100mm stroke dissipation. 712 kN ± 100mm stroke Deung Sun Bridge South Korea, Chuncheon Taylor Fluid Dampers 2006 Seismic Seismic retrofit of a 2000 meter multi-span steel girder bridge Total: 8 with dampers for the Ministry of Construction & 1000 kN ± 100mm stroke Transportation. ShinSang # 1 Bridge South Korea, Daejeon Taylor Fluid Dampers 2006 Seismic Seismic retrofit of a 525 meter multi-span steel girder bridge Total: 8 with dampers for the Korea Highway Corporation. 1000 kN ± 250mm stroke Lee Ho Grand Bridge South Korea, Yeoju Taylor Fluid Dampers 2006 Seismic Seismic retrofit of a 910 meter multi-span steel girder bridge Total: 4 with dampers for the Ministry of Construction & 1000 kN ± 310mm stroke Transportation. TSMC FAB #7 Taiwan, Hsin Chu City Taylor Fluid Dampers 2006 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 16 dissipate seismic energy and micro-vibrations. 1000 kN ± 100mm stroke Pamunkey River USA, West Point, VA Taylor Fluid Dampers 2006 Kinetic Energy of New bascule bridge replaces an aging bridge. Dampers are Total: 4 Moving Bridge used to protect the bascule leafs and ensure soft settling. 890 kN + 400mm stroke ITS Kenpo Okubo Union Hall Japan, Tokyo-Okubo Taylor Fluid Dampers 2006 Seismic New 7-story office building for Kanto IT software health Total: 18 insurance association. Dampers are used in diagonal braces to 1425 kN + 50mm stroke dissipate seismic energy. 1960 kN + 50mm stroke 2330 kN + 50mm stroke

Page 45 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information D - Asset VIII Nishi - Shinjyuku Japan, Tokyo-Shinjyuku Taylor Fluid Dampers 2006 Seismic New 13-story office building known as D-ASSETVIII. Building Total: 25 Dampers used in diagonal braces to dissipate seismic energy. 500 kN + 100mm stroke Waldo – Penebscot River Bridge USA, Verona, ME Taylor Fluid Dampers 2006 Wind/Rain New cable-stayed bridge and observation tower uses dampers Total: 160 attached to cable stays to reduce vibration from wind and 9 kN ± 63mm stroke rain. Marvell Building # 100, 200 and USA, Santa Clara, CA Taylor Fluid Dampers 2006 Seismic Seismic upgrade of existing structures and seismic protection Connector Building Total: 104 of new connecting structure. Dampers used in diagonal braces 890 kN + 76mm stroke to dissipate seismic energy. Marvell Building # 400 USA, Santa Clara, CA Taylor Fluid Dampers 2006 Seismic Seismic upgrade of existing structure. Dampers used in Total: 26 diagonal braces to dissipate seismic energy. 890 kN ± 76mm stroke 2935 kN ± 76mm stroke 4380 kN ± 76mm stroke Berryhill Elementary School USA, Ceres, CA Taylor Fluid Dampers 2006 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke Four Elementary Schools for the Ceres USA, Ceres, CA Taylor Fluid Dampers 2006 Seismic New school athletic complex uses dampers in chevron braces Unified School District Total: 32 to dissipate seismic energy. 107 kN ± 75mm stroke Adkison Elementary School USA, Ceres, CA Taylor Fluid Dampers 2006 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke Hidahl Elementary School USA, Ceres, CA Taylor Fluid Dampers 2006 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke LaRosa Elementary School USA, Ceres, CA Taylor Fluid Dampers 2006 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke 926 J Street 926 J Street Taylor Fluid Dampers 2006 Seismic Retrofit of a 1920’s vintage, 10,000 square meter concrete Total: 16 office building. Dampers used in diagonal bracing elements to 1557 kN ± 75mm stroke dissipate seismic energy. Kent Parking Garage USA, Kent, WA Taylor Fluid Dampers 2006 Seismic Seismic upgrade of a 3-story concrete parking garage. Total: 16 Dampers used in diagonal braces to dissipate seismic energy. 445 kN ± 100mm stroke Bercy Tolbiac Bridge France, Paris Taylor Fluid Dampers 2006 Pedestrian New footbridge uses special metal bellows dampers to reduce Total: 4 Traffic vibrations caused by pedestrian traffic. 34 kN ± 65mm stroke 53 kN ± 65mm stroke 82 kN ± 25mm stroke Chiba Chuo Project (6th area urban Japan, Chiba City Taylor Fluid Dampers 2006 Seismic New 15-story steel mixed-use office/retail/ science museum redevelopment project) Total: 42 building uses a combination of unbonded braces and dampers 980 kN ± 100mm stroke to dissipate seismic energy. 1960 kN ± 100mm stroke

Page 46 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Shibuya Park Road Building Japan, Tokyo Taylor Fluid Dampers 2006 Seismic New 7-story, 2,200 square meter reinforced concrete office Total: 10 building uses dampers to dissipate seismic energy. 2452 kN ± 125mm stroke 3149 kN ± 100mm stroke 5885 kN ± 100mm stroke Tainan Science Park Junction Bridge Taiwan, Tainan Taylor Fluid Dampers 2006 Seismic Dampers installed on top of the bridge piers, connecting the Total: 48 bottom of the post-stressing reinforced concrete I-beam for 785 kN ± 100mm stroke earthquake energy dissipation. Jan-Ron Ritz Building Taiwan, Taipei Taylor Fluid Dampers 2006 Seismic New 24-story reinforced concrete residential building uses Total: 64 dampers in A-shape supporting frame for earthquake energy 980 kN ± 100mm stroke dissipation. Ruentex Tun-Jen Building Taiwan, Taipei Taylor Fluid Dampers 2006 Seismic New 21-story steel-framed residential building uses dampers Total: 88 in A-shape supporting frame for earthquake energy 858 kN ± 100mm stroke dissipation. 1147 kN ± 100mm stroke Beijing Silvertie Center China, Beijing Taylor Fluid Dampers 2006 Seismic New 63-story building uses dampers in diagonal braces to Total: 73 reduce seismic and wind motion. 1200 kN ± 100mm stroke Bayer CMF Building #66 USA, Berkeley, CA Taylor Fluid Dampers 2005 Seismic New 2-story, 3,500 square meter clinical manufacturing Total: 88 facility utilizes dampers to reduce drift and dissipate seismic 858 kN ± 100mm stroke energy. 1147 kN ± 100mm stroke 1325 kN ± 100mm stroke Sinclear Elementary School USA, Ceres, CA Taylor Fluid Dampers 2005 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke Semiconductor Building USA, Silicon Valley, CA Taylor Fluid Dampers 2005 Seismic Seismic upgrade of a 2-story steel frame semiconductor Total: 26 manufacturing building uses dampers in diagonal braces. 890 kN ± 76mm stroke 2935 kN ± 76mm stroke 4380 kN ± 76mm stroke Logan Airport Central Parking Garage USA, Boston, MA Taylor Fluid Dampers 2005 Seismic Lock-up devices used as part of a seismic upgrade and Total: 96 expansion. Devices used between existing structure and new 133 kN ± 25mm stroke parking structure around original structure at the first and second floors. Mississippi River Bridge USA, Greenville, MS Taylor Fluid Dampers 2005 Seismic New cable-stayed bridge carries U.S. Hwy 82 over Mississippi Total: 8 River. 420 m main span is longest in the continental U.S. 4600 kN ± 152mm stroke Dampers control seismic movement while allowing for thermal movement. Spring Mountain Road Pedestrian USA, Las Vegas, NV Taylor Fluid Dampers 2005 Pedestrian Group of three new pedestrian bridges utilize Taylor tuned Bridges Total: 18 Traffic mass dampers to reduce pedestrian-induced vibrations. TMD Systems

Page 47 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Hammersly Wharf Australia Taylor Fluid Dampers 2005 Seismic East Intercourse Island Wharf Strengthening Project- Damper Total: 1 used to control seismic movement while allowing free thermal 1890 kN ± 75mm stroke movement. Jackson Street Bridge Australia, Fyshwick Taylor Fluid Dampers 2005 Seismic Shock Transmission Units used to control seismic movement Total: 2 while allowing free thermal movement. 400 kN ± 100mm stroke GerFu Business Center Taiwan, Taipei Taylor Fluid Dampers 2005 Seismic Structural retrofit of an office building. Dampers used in Total: 25 chevron braces to dissipate seismic energy. 490 kN ± 100mm stroke 980 kN ± 100mm stroke Nanjing 3rd Crossing Bridge China, Nanjing Taylor Fluid Dampers 2005 Seismic Dampers installed on the approaches of a new cable stayed Total: 54 bridge to control longitudinal earthquake movement while 1471 kN ± 120mm stroke allowing free thermal movement. Huabei Power Plant China, Shandong Taylor Fluid Dampers 2005 Equipment Dampers used to reduce equipment vibration. Total: 96 Vibration 8.9 kN ± 25.4mm stroke Zhengzhou Convention Center China, Zhengzhou Taylor Fluid Dampers 2005 Pedestrian New convention center floor utilizes tuned mass dampers to Total: 144 Traffic & reduce perceptible vibrations caused by walking and dancing 2 kN ± 25mm stroke Dancing inputs. Cyprus Olympic Building Cyprus, Nicosia Taylor Fluid Dampers 2005 Seismic New 3-story reinforced concrete building uses dampers in Total: 52 scissor-type toggle braces to dissipate seismic energy. 150 kN ± 50mm stroke Pont de Vatine Bridge France, Le Havre Taylor Fluid Dampers 2005 Kinetic Energy New movable pedestrian bridge uses a combination of lift, Total: 6 oscillation and rotational energy absorbers. 67 kN ± 102mm stroke 67 kN ± 152mm stroke 50 kN ± 152mm stroke Shinjuku 3-Chome East Building Japan, Tokyo-Shinjyuku Taylor Fluid Dampers 2005 Seismic New 14-story 26,400 square meter entertainment complex uses Total: 2 dampers to dissipate seismic energy. 2452 kN ± 150mm stroke Daebuk Gyo Bridge South Korea, Wulsan City Taylor Fluid Dampers 2005 Seismic Seismic retrofit of a three span steel girder highway bridge. Total: 4 868 kN ± 100mm stroke Alameda Mexico, Mexico City Taylor Fluid Dampers 2005 Seismic Conversion of a 1950's vintage parking garage to small Total: 34 apartments. Dampers used in diagonal bracing elements to 645 kN ± 75mm stroke dissipate seismic energy. Fubon/China Insurance Building Taiwan, Taipei Taylor Fluid Dampers 2005 Seismic New 16-story residential building uses dampers in diagonal Total: 124 braces to dissipate seismic energy. 490 kN ± 75mm stroke 785 kN ± 75mm stroke 1079 kN ± 75mm stroke 1275 kN ± 75mm stroke 1471 kN ± 75mm stroke

Page 48 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Kindom 101 Leadership Taiwan, Taipei Taylor Fluid Dampers 2005 Seismic New 18-story 13,000 square meter residential building uses Total: 23 dampers in diagonal bracing elements. 980 kN ± 50mm stroke National Palace Museum Taiwan, Taipei Taylor Fluid Dampers 2005 Seismic Retrofit of a well-known museum. Dampers used to dissipate Total: 172 seismic energy in this seven building complex. 500 kN ± 75mm stroke 1000 kN ± 75mm stroke Shin Keio Plaza Taiwan, Taipei Taylor Fluid Dampers 2005 Seismic New 22-story SRC residential building uses dampers in A- Total: 24 shape supporting frame for earthquake energy dissipation. 980 kN ± 152mm stroke Touch the Heart of Hawaii Taiwan, Taipei Taylor Fluid Dampers 2005 Seismic New 35,000 square meter 14-story reinforced concrete Total: 30 residential building uses a combination of dampers in diagonal 980 kN ± 50mm stroke and chevron braces. 1225 kN ± 75mm stroke Nordstrom South Coast Plaza USA, Costa Mesa, CA Taylor Fluid Dampers 2004 Seismic Retrofit of 23,000 square meter, 4-story steel moment frame Total: 40 retail building. Dampers used in chevron braces to dissipate 667 kN ± 100mm stroke seismic energy. 890 kN ± 100mm stroke Monroe Middle School USA, Campbell, CA Taylor Fluid Dampers 2004 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke Rolling Hills Middle School USA, Los Gatos, CA Taylor Fluid Dampers 2004 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke East Bay Municipal Utility District- USA, Oakland, CA Taylor Fluid Dampers 2004 Seismic Retrofit of 10-story steel structure. Dampers used in diagonal Administration Building Total: 50 and chevron braces to dissipate seismic energy. 1112 kN ± 127mm stroke 1446 kN ± 190mm stroke 2669 kN ± 165mm stroke CSUS-Academic Information Resources USA, Sacramento, CA Taylor Fluid Dampers 2004 Seismic New 10,000 square meter, 4-story steel frame building uses Center Total: 24 dampers in diagonal bracing elements to dissipate seismic 230 kN ± 50mm stroke energy. 260 kN ± 50mm stroke Vacaville Police Station USA, Vacaville, CA Taylor Fluid Dampers 2004 Seismic New 2-story, 4,000 square meter police headquarters uses Total: 20 dampers in diagonal braces to provide a cost-effective building 489 kN ± 50mm stroke that will provide immediate occupancy performance for a 475 890 kN ± 50mm stroke year return seismic event. Los Angeles Regional Transportation USA, Los Angeles, CA Taylor Fluid Dampers 2004 Seismic New construction with base isolation. These special dampers Management Center Total: 25 are equipped with an automatic wind-lock mechanism, while 1450 kN ± 660mm stroke also functioning as seismic energy absorbers.

Page 49 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Richmond-San Rafael Bridge USA, Richmond, CA Taylor Fluid Dampers 2004 Seismic Retrofit of a 4.5 mile steel truss bridge designed in the 1950's. Total: 28 Dampers used to dissipate seismic energy and allow the bridge 1000 kN ± 965mm stroke to withstand a maximum credible earthquake. 2225 kN ± 508mm stroke George Washington Bridge USA, Seattle, WA Taylor Fluid Dampers 2004 Seismic Retrofit of a large steel truss bridge. Devices used to control Total: 4 seismic movement while allowing free thermal movement. 4900 kN ± 75mm stroke Weirton-Steubenville, Veterans Weirton, WV Taylor Fluid Dampers 2004 Wind & Rain Retrofit of a cable-stayed bridge. Dampers attached to cable Memorial Bridge Total: 88 stays to reduce cable vibration induced by a combination of 9 kN ± 25mm stroke wind and rain. 2.5 kN ± 25mm stroke Veterans Memorial Bridge - Texas USA, Groves, TX Taylor Fluid Dampers 2004 Wind Retrofit of a cable-stayed bridge. Dampers attached to cable Total: 80 stays to reduce motion induced by a combination of wind and 25 kN ± 150mm stroke rain. TSMC FAB #5 Taiwan, Hsin Chu City Taylor Fluid Dampers 2004 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 44 dissipate seismic energy and micro-vibrations. 981 ± 75mm stroke 1471 ± 75mm stroke TSMC FAB #8 Taiwan, Hsin Chu City Taylor Fluid Dampers 2004 Seismic Retrofit of a semiconductor fabrication plant uses dampers to Total: 58 dissipate seismic energy and micro-vibrations. 785 ± 38mm stroke 1422 ± 220mm stroke 1452 ± 50mm stroke Uni-President Headquarters Taiwan, Taipei Taylor Fluid Dampers 2004 Seismic Retrofit of residential building to reduce seismic drift and Total: 52 forces after adding 2 additional floors on top of the structure. 980 kN ± 75mm stroke Dampers used in chevron and diagonal braces to dissipate 980 kN ± 100mm stroke seismic energy. 1960 kN ± 75mm stroke Grand Master Construction Residential Taiwan, Taipei Taylor Fluid Dampers 2004 Seismic New 14-story steel reinforced concrete residential building Building (KCEC) Total: 32 uses dampers in chevron braces for earthquake energy 980 kN ± 50mm stroke dissipation. 735 kN ± 50mm stroke Temple Lofts USA, Long Beach, CA Taylor Fluid Dampers 2004 Seismic Conversion of a Masonic Temple to condominiums. Dampers Total: 64 used in chevron braces to dissipate seismic energy. 667 kN ± 75 mm stroke 890 kN ± 75 mm stroke Coldhams Lane Bridge UK, Cambridge Taylor Fluid Dampers 2004 Vehicle Collision Lock-up devices installed on a small footbridge to prevent the Total: 2 bridge from falling off its piers if a vehicle collides with the 100 kN ± 75mm stroke bridge. Kuo Mei Building Taiwan, Taipei Taylor Fluid Dampers 2004 Seismic New 14-story residential building uses dampers in chevron Total: 4 braces to dissipate seismic energy. 981 kN ± 75mm stroke

Page 50 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Hotel Stockton USA, Stockton, CA Taylor Fluid Dampers and 2004 Seismic Seismic retrofit of a 6-story historic concrete structure with a Viscoelastic Dampers combination of fluid viscous and fluid viscoelastic dampers in Total: 20 diagonal braces. 890 kN ± 100mm stroke 1668 kN ± 38mm stroke Taishin Bank Headquarters Taiwan, Taipei Taylor Fluid Dampers 2003-2004 Seismic New 28-story steel framed office building uses dampers in Total: 72 chevron braces for earthquake energy dissipation. 980 kN ± 75mm stroke 1470 kN ± 75mm stroke 1962 kN ± 75mm stroke Cross Keys Bridge UK, South Lincolnshire Taylor Fluid Dampers 2003 Braking/Traction Retrofit/upgrade of an old swing bridge. Device used to Total: 1 control braking/traction forces while allowing free thermal 330 kN ± 92mm stroke movement. Guitai Construction Residential Building Taiwan, Taipei Taylor Fluid Dampers 2003 Seismic New 9-story steel reinforced concrete residential building uses (KCEC) Total: 28 dampers in chevron braces for earthquake energy dissipation. 735 kN ± 50mm stroke Hilmar Gymnasium USA, Hilmar, CA Taylor Fluid Dampers 2003 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke New de Young Fine Arts Museum USA, San Francisco, CA Taylor Fluid Dampers 2003 Seismic New base isolated building uses fluid viscous dampers to add Total: 26 energy dissipation to isolation system for premium seismic 1112 kN ± 762mm stroke performance. PSU - Smith Memorial Center Building USA, Portland, OR Taylor Fluid Dampers 2003 Seismic Seismic upgrade to Portland State University Building. Total: 118 Dampers are used in chevron braces throughout this 4-story 400 kN ± 75mm stroke structure. 845 kN ± 75mm stroke Renton Transfer Station USA, Renton, WA Taylor Fluid Dampers 2003 Wind New King County recycling center roof structure uses Total: 3 dampers in diagonal knee-brace for seismic energy dissipation. 290 kN ± 75mm stroke Parklane Apartments New Zealand, Wellington Taylor Fluid Dampers 2003 Wind Retrofit of residential apartment building with dampers in two Total: 8 tuned mass dampers to reduce motion caused by wind. 10 kN ± 89mm stroke Pearson Airport Control Tower Canada, Toronto, ON Taylor Fluid Dampers 2003 Wind New air traffic control tower uses dampers as part of a tuned Total: 8 mass damper to reduce motion caused by wind. 31 kN ± 89mm stroke Peace & Friendship Stadium Greece, Athens Taylor Fluid Dampers 2003 Seismic Seismic upgrade and renovation to the roof of an isolated Total: 128 saddle-shaped stadium used for the 2004 Olympics in Athens. 1000 kN ± 85mm stroke 1200 kN ± 60mm stroke Pietrasanta Residences Venezuela, Taylor Fluid Dampers 2003 Seismic New 11-story residential building uses dampers to absorb Barquisimeto Total: 24 seismic energy to provide unparalleled performance in this 245 kN ± 75mm stroke premium caliber structure.

Page 51 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Solano County Government Building USA, Fairfield, CA Taylor Fluid Dampers 2003 Seismic New government building utilizes dampers in chevron braces Total: 20 to dissipate seismic energy. 1560 kN ± 75mm stroke Soldier Field USA, Chicago, IL Taylor Fluid Dampers 2003 Spectator New seating bowl for football stadium uses dampers in tuned Total: 42 Vibration mass dampers to reduce motion caused by spectator 9 kN ± 50mm stroke movements. Taiwan High Speed Rail - Section C270 Taiwan, Yun Lin Taylor Fluid Dampers 2003 Seismic New high speed railway bridge sections use dampers to control Total: 34 movement at expansion joints during earthquake and train 3900 kN ± 125mm stroke braking events. Holland Hills Mori Tower RoP Japan, Tokyo Taylor Fluid Dampers 2003 Seismic New construction, 24-story building uses dampers to dissipate Total: 204 earthquake energy to reduce demands on the structure. 650 kN ± 100mm stroke 1300 kN ± 100mm stroke 1800 kN ± 100mm stroke Cochrane Bridge USA, Mobile, AL Taylor Fluid Dampers 2003 Wind Retrofit of a cable-stayed bridge. Dampers attached to cable Total: 68 stays to reduce motion induced by a combination of wind and 40 kN ± 150mm stroke rain. 22 kN ± 150mm stroke Chung Hwa Telecommunications Taiwan, San Hwa Taylor Fluid Dampers 2003 Seismic Retrofit of Taiwan Government-owned 3-story office and Building Total: 12 equipment telecommunications building. Uses dampers in 1570 kN ± 100mm stroke chevron braces for earthquake energy dissipation. San Francisco-Oakland Bay Bridge, USA, San Francisco, CA Taylor Fluid Dampers 2003 Seismic Retrofit of suspension span between San Francisco and Yerba West Span- Suspension Bridge Total: 100 Buena island. Dampers used to dissipate seismic energy. 2000 kN ± 483mm stroke 2450 kN ± 584mm stroke 3115 kN ± 178mm stroke Abernethy Bridge USA, Oregon City, OR Taylor Fluid Dampers 2002-2003 Seismic Retrofit of an existing bridge. Dampers used to control Total: 32 earthquake movement and distribute forces while allowing 1000 kN ± 55mm stroke free thermal movement. 1500 kN ± 75mm stroke 750 kN ± 155mm stroke Route 364 Page Avenue Extension USA, St. Louis, MO Taylor Fluid Dampers 2002-2003 Seismic New tied arch/ uses dampers to control Bridge Total: 178 longitudinal earthquake movement while allowing free 1050 kN ± 50mm stroke thermal movement. 756 kN ± 70mm stroke 1824 kN ± 50mm stroke 2225 kN ± 92mm stroke 556 kN ± 127mm stroke 867 kN ± 127mm stroke Atatürk Airport Expansion Turkey, Istanbul Taylor Fluid Dampers 2002 Seismic Extension of International Terminal required additional Total: 68 damping devices to control deflection and minimize thermal 45 kN ± 25mm stroke restrictions of roof structure supported on FPS isolators.

Page 52 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information BCBC Pandora Wing Canada, Victoria, BC Taylor Fluid Dampers 2002 Seismic Retrofit of a 7-story concrete frame/shear wall building built Total: 76 in 1974. Dampers used in chevron braces. 220 kN ± 57mm stroke 130 kN ± 57mm stroke Boise Airport USA, Boise, ID Taylor Fluid Dampers 2002 Seismic & Wind New construction, airport terminal building uses dampers to Total: 8 dissipate earthquake energy to reduce demands on the 445 kN ± 57mm stroke structure. 756 kN ± 84mm stroke 979 kN ± 127mm stroke Buddhist Headquarters Taiwan, Taipei Taylor Fluid Dampers 2002 Seismic New construction, 17-story building uses dampers to dissipate Total: 60 earthquake energy. 981 kN ± 75mm stroke Gillette (Foxboro) Stadium USA, Foxboro, MA Taylor Fluid Dampers 2002 Seismic Dampers installed across expansion joints of a new open-air Total: 18 football stadium to control motion caused by seismic events. 222 kN ± 178mm stroke Bill Emerson Memorial Bridge USA, Cape Girardeau, MO Taylor Fluid Dampers 2002 Seismic New construction of a cable-stayed bridge. Dampers used to (Cape Girardeau) Total: 16 control longitudinal earthquake movement while allowing free 6700 kN ± 180mm stroke thermal movement. Torre Mayor (Chapultepec Tower) Mexico, Mexico City Taylor Fluid Dampers 2002 Seismic New 55-story high-rise office/hotel tower uses dampers in Total: 98 mega-braces to dissipate earthquake energy. 5600 kN ± 52mm stroke 2770 kN ± 52mm stroke Discovery Bay Gymnasium USA, Discovery Bay, CA Taylor Fluid Dampers 2002 Seismic New school athletic complex uses dampers in chevron braces Total: 8 to dissipate seismic energy. 107 kN ± 75mm stroke Genentech FRC II USA, San Francisco, CA Taylor Fluid Dampers 2002 Seismic New construction, 3-story multi-building complex uses Total: 192 dampers to dissipate earthquake energy. 667 kN ± 102mm stroke 890 kN ± 102mm stroke 1334 kN ± 102mm stroke HP Invent Building 5 USA, Corvallis, OR Taylor Fluid Dampers 2002 Seismic Voluntary seismic upgrade of a critical manufacturing facility. Total: 18 Dampers are used in diagonal bracing to dissipate seismic 400 kN ± 100mm stroke energy. 135 kN ± 100mm stroke Hollister Gymnasiums USA, Hollister, CA Taylor Fluid Dampers 2002 Seismic Voluntary seismic upgrade of a critical manufacturing facility. Total: 40 Dampers are used in diagonal bracing to dissipate seismic 106 kN ± 76mm stroke energy. Hsien Dien/Tzu Chi Hospital Taiwan, Taipei Taylor Fluid Dampers 2002 Seismic New construction, dampers used to add energy dissipation to a Total: 48 base isolation system. 890 kN ± 810mm stroke Immunex Corporation Helix Project – USA, Seattle, WA Taylor Fluid Dampers 2002 Seismic New construction, 3-story steel frame building uses dampers to Central Utility Plant Total: 16 dissipate earthquake energy to reduce demands on the 1670 kN ± 75mm stroke structure and switchgear equipment.

Page 53 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information INTERCENTRO Dominican Republic, Santo Taylor Fluid Dampers 2002 Seismic New construction, 18-story steel frame building uses dampers Domingo Total: 48 to dissipate earthquake energy to reduce demands on the 950 kN ± 50mm stroke structure. 1565 kN ± 50mm stroke 2240 kN ± 50mm stroke Poplar Street Bridge USA, St. Louis, MO Taylor Fluid Dampers 2002 Seismic Large highway bridge over the Mississippi River uses dampers Total: 64 to control longitudinal earthquake movement while allowing 1334 kN ± 183mm stroke free thermal movement. 2224 kN ± 229mm stroke South Bay Office Tower USA, San Jose, CA Taylor Fluid Dampers 2002 Seismic Retrofit of a 10-story office building to upgrade seismic Total: 88 performance of flexible floor to column systems. 490 kN ± 125mm stroke Stacy Park Reservoir USA, St. Louis, MO Taylor Fluid Dampers 2002 Seismic Seismic retrofit of an 8-section cover for a water reservoir. Total: 193 Dampers used to control motion caused by seismic events. 222 kN ± 63mm stroke 445 kN ± 63mm stroke UC Irvine Hall Building USA, Irvine, CA Taylor Fluid Dampers 2002 Seismic Retrofit/seismic improvements to Graduate School of Total: 14 Management Building. Dampers are used in diagonal braces 267 kN ± 75mm stroke to provide energy dissipation for seismic events. 10th & K Street USA, Sacramento, CA Taylor Fluid Dampers 2001 Seismic Seismic retrofit of an office building. Dampers used in Total: 4 diagonal braces for seismic energy dissipation. 823 kN ± 76mm stroke 999 Sepulveda USA, Los Angeles, CA Taylor Fluid Dampers 2001 Seismic Retrofit of an 8-story steel frame building built in 1962. Total: 60 Dampers used in diagonal braces to dissipate seismic energy. 2670 kN ± 75mm stroke Dexter Horton Building USA, Seattle, WA Taylor Fluid Dampers 2001 Seismic Seismic retrofit of a 15-story concrete frame/shear wall Total: 18 building. Dampers used in diagonal braces to dissipate seismic 1112 kN ± 63mm stroke energy. First International Computer Company Taiwan, Taipei Taylor Fluid Dampers 2001 Seismic New construction, 14-story building uses dampers to dissipate Building Total: 144 earthquake energy. Cousin building to Taishin Bank. 266 kN ± 50mm stroke 434 kN ± 50mm stroke 583 kN ± 50mm stroke 989 kN ± 63mm stroke 1349 kN ± 63mm stroke Hearst Memorial Mining Building USA, Berkeley, CA Taylor Fluid Dampers 2001 Seismic Seismic retrofit of a 4-story brick laboratory building on the Total: 26 U.C. Berkeley campus. Dampers provide energy dissipation 890 kN ± 813mm stroke for a seismic isolation system. J-city TOKYO Office Tower Japan, Tokyo Taylor Fluid Dampers 2001 Seismic New construction, 23-story building uses dampers to dissipate Total: 241 earthquake energy to reduce demands on the structure. 785 kN ± 50mm stroke 1275 kN ± 75mm stroke

Page 54 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Millennium Bridge UK, London Taylor Fluid Dampers 2001 Pedestrian Retrofit of pedestrian bridge to reduce lateral and vertical Total: 37 Traffic movements caused by large groups of people walking on the 50 kN ± 25mm stroke bridge. Special metal bellows dampers used for maintenance- 50 kN +153/-377mm stroke free operation over the life of the bridge under continuous 50 kN + 40/-80mm stroke cycling. New Westminster, BC Police Building Canada, New Westminster, Taylor Fluid Dampers 2001 Seismic Retrofit of a 4-story concrete frame/shear wall building built BC Total: 12 in 1939. Dampers used in chevron braces inside new steel 890 kN ± 70mm stroke moment frames to balance irregularities in the building’s stiffness. Palo Alto Office Building USA, Palo Alto, CA Taylor Fluid Dampers 2001 Seismic Seismic retrofit of an office building. Dampers used in Total: 22 chevron braces to dissipate seismic energy. 1670 kN ± 152mm stroke Sacramento River Bridge at Rio Vista USA, Rio Vista, CA Taylor Fluid Dampers 2001 Seismic Seismic retrofit of lift bridge towers to dampen the rocking Total: 10 effect during an earthquake. 825 kN ± 133mm stroke Taishin Bank Taiwan, Taipei Taylor Fluid Dampers 2001 Seismic New construction, 14-story building uses dampers to dissipate Total: 144 earthquake energy. Cousin building to First International 266 kN ± 50mm stroke Computer Company Building. 434 kN ± 50mm stroke 583 kN ± 50mm stroke 989 kN ± 63mm stroke 1349 kN ± 63mm stroke Tokyo Rinkai Hospital Japan, Tokyo Taylor Fluid Dampers 2001 Seismic New construction, dampers used to add energy dissipation to a Total: 45 base isolation system. 890 kN ± 813mm stroke WorldCom – Local Switch USA, Oakland, CA Taylor Fluid Dampers 2001 Seismic Seismic retrofit of a 17-story building. Dampers used in Total: 20 diagonal braces. 2225 kN ± 75mm stroke 2225 kN ± 150mm stroke 111 Huntington Avenue USA, Boston, MA Taylor Fluid Dampers 2000 Wind New construction, 38-story building uses a combination of Total: 60 direct acting dampers and toggle brace dampers to reduce 1300 kN ± 101mm stroke motion caused by wind storms. Amolanas Bridge Chile, Santiago Taylor Fluid Dampers 2000 Seismic New bridge utilizes dampers to absorb earthquake energy, Total: 4 reduce movement and distribute forces while allowing free 3000 kN ± 200mm stroke thermal movement. Atatürk Airport Turkey, Istanbul Taylor Fluid Dampers 2000 Seismic New international terminal with FPS isolators uses dampers to Total: 120 control deflection and minimize thermal restrictions. 45 kN ± 25mm stroke East Huntington Bridge USA, Huntington, WV Taylor Fluid Dampers 2000 Wind Retrofit of a cable-stayed bridge. Dampers attached to cables Total: 54 to reduce vibrations caused by a combination of wind and 5 kN ± 25mm stroke rain. 3 kN ± 25mm stroke

Page 55 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Ingram Micro Office Building USA, Santa Ana, CA Taylor Fluid Dampers 2000 Seismic Voluntary seismic upgrade to this 3-story office building. Total: 7 Utilizes dampers in chevron braces for seismic energy 490 kN ± 127mm stroke dissipation. William H. Harsha (Maysville Bridge) USA, Maysville, KY Taylor Fluid Dampers 2000 Seismic New bridge utilizes dampers to control earthquake movement Total: 8 and distribute forces while allowing free thermal movement. 1300 kN ± 305mm stroke Millennium Place USA, Boston, MA Taylor Fluid Dampers 2000 Wind New construction, 37-story building uses dampers with toggle Total: 40 braces to reduce motion caused by wind storms. 445 kN ± 125mm stroke Novelty Bridge #404B USA, Seattle, WA Taylor Fluid Dampers 2000 Seismic Replacement bridge project in King County uses dampers to Total: 8 allow thermal movement and restrict seismic movements. 1450 kN ± 100mm stroke Qinshan III Nuclear Powerplant China, Shanghai Taylor Fluid Dampers 2000 Seismic New powerplant uses dampers in heat exchanger for seismic Total: 16 strengthening. 445 kN ± 127mm stroke Romanian Oil Refinery Romania, Bucharest Taylor Fluid Dampers 2000 Seismic Seismic retrofit of a 36-meter tower with a 600 tonnes mass on Total: 8 top. Dampers used as part of a tuned mass damping system to 33.3 kN ± 250mm stroke dissipate energy. Triborough Bridge Approaches USA, New York, NY Taylor Fluid Dampers 2000 Seismic Retrofit of the approaches to a suspension bridge. Dampers Total: 80 used to control earthquake movement and distribute forces 445 kN ± 152mm stroke while allowing free thermal movement. Web-hosting Data Center USA, Pleasanton, CA Taylor Fluid Dampers 2000 Seismic Voluntary seismic upgrade of a computer facility. Dampers Total: 32 used in chevron braces to dissipate seismic energy. 310 kN ± 64mm stroke Yerba Buena Tower USA, San Francisco, CA Taylor Fluid Dampers 2000 Wind Voluntary seismic upgrade of a computer facility. Dampers Total: 20 used in chevron braces to dissipate seismic energy. 445 kN ± 125mm stroke 1414 K Street USA, Sacramento, CA Taylor Fluid Dampers 1999 Seismic Retrofit of an existing office building. Dampers used in Total: 8 diagonal braces to dissipate earthquake energy. 1125 kN ± 63mm stroke Minute Maid Park (Ballpark at Union USA, Houston, TX Taylor Fluid Dampers 1999 Wind New baseball stadium utilizes dampers to mitigate the effects Station) Total: 16 of hurricane force winds on the roof structure. 300 kN ± 153mm stroke Beijing Railway Station China, Beijing Taylor Fluid Dampers 1999 Seismic Retrofit of a railway station. Dampers used in chevron Total: 32 bracing elements to dissipate earthquake energy. 1300 kN ± 44mm stroke Hyatt Park Tower USA, Chicago, IL Taylor Fluid Dampers 1999 Wind New 67-story reinforced concrete structure uses dampers as Total: 10 part of a Tuned Mass Damper to improve occupant comfort 45 kN ± 500mm stroke during wind storms. 22 kN ± 265mm stroke 45 kN ± 300mm stroke 175 kN ± 100mm stroke

Page 56 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information I–5/91 HOV Bridge USA, Anaheim, CA Taylor Fluid Dampers 1999 Seismic New bridge uses dampers to dissipate earthquake energy for Total: 8 reduced demands on the structure. 1110 kN ± 200mm stroke Los Angeles City Hall USA, Los Angeles, CA Taylor Fluid Dampers 1999 Seismic Retrofit of City Hall building with dampers used to add Total: 68 energy dissipation to base isolation system. Also uses dampers 1400 kN ± 600mm stroke at 27th floor to protect tower from earthquakes. 1000 kN ± 115mm stroke Microsoft Silicon Valley Campus – USA, Mountain View, CA Taylor Fluid Dampers 1999 Seismic New construction, 10,000 square meter computer data center Building 1 Total: 15 with dampers used in chevron bracing elements to dissipate 1000 kN ± 75mm stroke seismic energy. San Francisco International Airport - USA, San Francisco, CA Taylor Fluid Dampers 1999 Seismic New Airport Rail Transit (ART) and Bay Area Rapid Transit Rail Transit System Westside Guideway Total: 10 (BART) structure implement dampers for earthquake energy 4225 kN ± 508mm stroke dissipation. 3115 kN ± 508mm stroke San Francisco International Airport - USA, San Francisco, CA Taylor Fluid Dampers 1999 Seismic New pedestrian bridge utilizes dampers to dissipate South International Parking Garage Total: 20 earthquake energy and reduce movement. Pedestrian Bridge 445 kN ± 254mm stroke San Francisco - Oakland Bay Bridge, USA, San Francisco, CA Taylor Fluid Dampers 1999 Seismic Interim retrofit of East Bay 504 truss sections. Dampers used East Span - Truss Bridge Total: 6 to dissipate seismic energy. 890 kN ± 406mm stroke Santa Clara Police Facility USA, Santa Clara, CA Taylor Fluid Dampers 1999 Seismic New police facility utilizes dampers in chevron bracing Total: 40 elements to dissipate earthquake energy. 575 kN ± 25mm stroke 800 kN ± 25mm stroke Sidney Lanier Bridge USA, Glynn County, GA Taylor Fluid Dampers 1999 Seismic New bridge utilizes dampers to control earthquake movement 2200 kN ± 203mm stroke and distribute forces while allowing free thermal movement.

The Nethercutt Collection USA, Sylmar, CA Taylor Fluid Dampers 1999 Seismic New construction, automotive museum with dampers used in Total: 32 diagonal braces to dissipate seismic energy. 1500 kN ± 75mm stroke 1065 kN ± 75mm stroke 665 kN ± 75mm stroke Transbay Transit Terminal USA, San Francisco, CA Taylor Fluid Dampers 1999 Seismic Retrofit of a bus terminal. Dampers used in chevron bracing Total: 36 elements to dissipate earthquake energy. 1300 kN ± 44mm stroke 1300 kN ± 76mm stroke Willamette River Pedestrian Bridge USA, Eugene, OR Taylor Fluid Dampers 1999 Seismic & Wind Retrofit of a bridge over the Willamette River. Dampers used Total: 4 to control wind and earthquake movement while allowing free 500 kN ± 40mm stroke thermal movement. SAFECO Field (New Pacific Northwest USA, Seattle, WA Taylor Fluid Dampers 1998-1999 Wind & Kinetic Dampers installed between three roof sections and at end stops Baseball Park) Total: 36 Energy to absorb energy from impact due to wind, kinetic energy and 1780 kN ± 100mm stroke motor drive. 890 kN ± 400mm stroke

Page 57 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information First Avenue South Bridge USA, Seattle, WA Taylor Fluid Dampers 1998 Kinetic Energy of Retrofit of a bascule bridge to protect the bascule leafs from Total: 4 Moving Bridge runaway motors and brake failures. 600 kN + 635mm stroke SAFECO Field (New Pacific Northwest USA, Seattle, WA Taylor Fluid Dampers 1998 Seismic & Wind New baseball stadium utilizes dampers to dissipate earthquake Baseball Park) Total: 8 energy in each of three movable roof sections. 3600 kN ± 381mm stroke Tillamook Hospital USA, Tillamook, OR Taylor Fluid Dampers 1998 Seismic Retrofit of an existing hospital to meet current seismic Total: 30 protection code levels. Dampers used in chevron braces to 135 kN ± 50mm stroke dissipate earthquake energy. UCLA-Knudsen Hall USA, Los Angeles, CA Taylor Fluid Dampers 1998 Seismic Seismic upgrade of a University building. Dampers used in Total: 84 chevron bracing elements to dissipate earthquake energy. 355 kN ± 100mm stroke 245 kN ± 100mm stroke Alaska Commercial Building USA, Alaska Taylor Fluid Dampers 1997 Seismic Retrofit of a timber frame structure. Dampers used in Total: 2 diagonal bracing to dissipate earthquake energy. 445 kN ± 64mm stroke CSULA Administration Building USA, Los Angeles, CA Taylor Fluid Dampers 1997 Seismic Seismic upgrade to office building. Dampers used in chevron Total: 14 bracing elements to dissipate seismic energy. 1100 kN ± 75mm stroke Hayward City Hall USA, Hayward, CA Taylor Fluid Dampers 1997 Seismic New construction, dampers used to add energy dissipation to Total: 15 friction pendulum bearing isolation system. 1400 kN ± 600mm stroke Quebec Iron and Titanium Smelter Canada, Tracy Taylor Spring Dampers and 1997 Seismic & Wind Dual purpose spring dampers used for seismic and wind Taylor Dampers protection of two smelter buildings. Dampers used to prevent Total: 22 buildings from impacting during a seismic event. 450 kN ± 64mm stroke 225 kN ± 100mm stroke 130 kN ± 100mm stroke Rockwell Building 505 USA, Newport Beach, CA Taylor Fluid Dampers 1997 Seismic Retrofit of a long building with multiple expansion gaps. Total: 6 Dampers restrict relative movement between building sections. 320 kN ± 64mm stroke San Francisco Civic Center USA, San Francisco, CA Taylor Fluid Dampers 1997 Seismic New construction, 14-story, 80,000 square meter Government Total: 292 office building with dampers in diagonal bracing elements to 1000 kN ± 100mm stroke dissipate seismic energy. 550 kN ± 100mm stoke Studio Parking Garage USA, Los Angeles, CA Taylor Fluid Dampers 1997 Seismic Dampers used to allow thermal motion, concrete Total: 2 expansion/contraction and creep, while controlling earthquake 150 kN ± 50mm stroke movement. Worcester’s Centrum Centre/Arena and USA, Worcester, MA Taylor Fluid Dampers 1997 Pedestrian Ballroom floor tuned mass damping system to eliminate Convention Complex Total: 32 Traffic & perceptible vibrations due to dancing input and other potential 10 kN ± 75mm stroke Dancing input motions. 28 State Street USA, Boston, MA Taylor Fluid Dampers 1996 Wind Wind dampers used in diagonal bracing for comfort level Total: 40 improvements to a completely renovated high-rise office 670 kN ± 25mm stroke building.

Page 58 of 59 2018 Name and Type of Structure Country / City Type and Number of Dampers Date Load Additional Information Arrowhead Regional Medical Center (5 USA, San Bernardino, CA Nonlinear Taylor Fluid Dampers 1996 Seismic New construction, dampers used to add energy dissipation to buildings) Total: 186 rubber bearing isolation system in five independently isolated 1400 kN ± 600mm stroke buildings. CSUS Science II Building USA, Sacramento, CA Taylor Fluid Dampers 1996 Seismic Seismic dampers used in chevron bracing of this new structure Total: 40 to dissipate seismic energy. 220 kN ± 50mm stroke First Avenue Bridge USA, Seattle, WA Taylor Fluid Dampers 1996 Kinetic Energy of Protection of new bascule leafs from runaway motors and Total: 4 Moving Bridge brake failures. 400 kN + 685mm stroke Hotel Woodland USA, Woodland, CA Taylor Fluid Dampers 1996 Seismic Seismic retrofit of 4-story historic concrete structure with Total: 16 fluid dampers in chevron bracing. 450 kN ± 50mm stroke Kaiser Data Center USA, Corona, CA Taylor Fluid Dampers 1996 Seismic Seismic retrofit with dampers used to add energy dissipation Total: 16 to rubber bearing isolation system. 425 kN ± 560mm stroke Langenbach House USA, Oakland, CA Taylor Fluid Dampers 1996 Seismic Seismic dampers used to provide energy dissipation in base Total: 4 isolation system. 130 kN ± 150mm stroke Montlake Bridge USA, Seattle, WA Taylor Fluid Dampers 1996 Kinetic Energy of Retrofit of a bascule bridge to protect the bascule leafs from Total: 4 Moving Bridge runaway motors and brake failures. 240 kN ± 483mm stroke The Money Store National Headquarters USA, Sacramento, CA Taylor Fluid Dampers 1996 Seismic New construction, pyramid shaped 11-story office building, Total: 120 moment frame structure with dampers in diagonal braces. 1290 kN ± 64mm stroke 710 kN ± 64 mm stroke Pacific Bell North Area Operation USA, Sacramento, CA Taylor Fluid Dampers 1995 Seismic New construction, 3-story steel braced frame, dampers in Center Total: 62 chevron braces used to dissipate seismic energy. 130 kN ± 50mm stroke Petronas Twin Towers Malaysia, KLCC Taylor Fluid Dampers 1995 Wind Kuala Lumpur City Centre high-rise towers, part of mass Total: 12 damping system in skybridge legs. 10 kN ± 50mm stroke Ralph Wilson Stadium USA, Buffalo, NY Taylor Fluid Dampers 1993 Wind Wind dampers connect light poles to the stadium parapet wall Total: 12 to eliminate base plate anchor bolt fatigue. 50 kN ± 460mm stroke West Seattle Bridge USA, Seattle, WA Taylor Fluid Dampers 1990 Kinetic Energy of Deck isolation for swing bridge. Total: 6 Moving Bridge 1000 kN + 406mm stroke 2515 kN + 254mm stroke North American Air Defense Command USA, Cheyenne Mountain, Taylor Dampers 1984 Nuclear Attack Classified. CO Quantity, type, and size are classified

Page 59 of 59 2018