GLWA 2022-2026 CIP – Appendix D – System Information
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
A Model-Based Assessment of Infiltration and Inflow in the Scope of Controlling Separate Sanitary Overflows at Pumping Stations Olivier Raynaud, C
A model-based assessment of infiltration and inflow in the scope of controlling separate sanitary overflows at pumping stations Olivier Raynaud, C. Joannis, Franck Schoefs, F. Billard To cite this version: Olivier Raynaud, C. Joannis, Franck Schoefs, F. Billard. A model-based assessment of infiltration and inflow in the scope of controlling separate sanitary overflows at pumping stations. 11thInter- national Conference on Urban Drainage (ICUD 08), 2008, Edinburgh (Sotland), United Kingdom. hal-01007760 HAL Id: hal-01007760 https://hal.archives-ouvertes.fr/hal-01007760 Submitted on 18 Nov 2017 HAL is a multi-disciplinary open access L’archive ouverte pluridisciplinaire HAL, est archive for the deposit and dissemination of sci- destinée au dépôt et à la diffusion de documents entific research documents, whether they are pub- scientifiques de niveau recherche, publiés ou non, lished or not. The documents may come from émanant des établissements d’enseignement et de teaching and research institutions in France or recherche français ou étrangers, des laboratoires abroad, or from public or private research centers. publics ou privés. A model-based assessment of infiltration and inflow in the scope of controlling separate sanitary overflows at pumping stations O. Raynaud1, C. Joannis1, F. Schoefs2, F. Billard3 1Laboratoire Central des Ponts et Chaussées, Route de Bouaye, B.P 4129, 44 341 Bouguenais Cedex, France 2Institut de Recherche en Génie Civil et Mécanique (Gém), Nantes, France 3Nantes Métropole, Direction de l’assainissement, Nantes, France ABSTRACT Infiltration & Inflow (I&I) are a major cause for separate sanitary sewers overflows (SSOs). A proper planning of actions for controlling SSOs needs a precise quantification of these events, as well as an identification of the respective contributions of infiltration into sewer and inappropriate connection of runoff water to sanitary sewers. -
Packaged Pump Stations Xylem’S Market Leading Products Will Save You Time and Money
Flygt N-technology parts and upgrade kits CLOG-FREE PUMPING. MINIMIZED ENERGY COSTS. • Self-cleaning impeller • Cutting groove provides seal protection • Well-balanced and modular design • High energy efficiency • Resistant materials • Adaptive N-hydraulics • Upgrade kits • Tight tolerances Packaged Pump Stations Xylem’s market leading products will save you time and money Service centres Australia New Zealand Adelaide: Karratha: Leewood: Auckland (head office): 22 Starr Avenue, Lot 4605 Croydon Road, 48 Leewood Drive, Orange 9 Tawa Drive, Albany, North Plympton, SA 5037 Karratha Industrial Estate, NSW 2800 Auckland 0632 Ph +61 8 8350 7100 Karratha WA 6714 Ph +61 2 9832 6730 Ph +64 9 415 8687 Fax +61 8 8350 7111 Ph +61 8 9183 8246 Fax +61 2 9832 6731 Fax +64 9 415 8679 Fax +61 8 9183 8248 Brisbane: Perth: Christchurch: Unit 1/39-45 Aquarium Ave Mackay: 76 Tarlton Crescent, Unit 6, 4 O’Briens Rd, Hemmant QLD 4174 7 Merchant Street, Paget, Perth Airport, WA 6105 Sockburn, Christchurch 8042 PO Box 2331 Mackay QLD 4740 Ph +61 8 9475 1900 Ph +64 3 348 4612 Mansfield QLD 4122 Ph +61 7 4842 9200 Fax +61 8 9475 1999 Fax +64 3 348 4629 Ph +61 7 3908 4000 Fax +61 7 4842 9299 Fax +61 7 3908 4199 Sydney (head office): Wellington: Melbourne: Unit 2, 2 Capicure Drive, c/9 Tawa Drive, Albany North Darwin: Unit 3, 1 Federation Way, Eastern Creek NSW 2766 Harbour, Auckland 29 McCourt Road, Chifley Business Park, Ph +61 2 9832 6200 Ph +64 021 746 441 Yarrawonga, NT 0830 Mentone VIC 3194 Fax +61 2 9832 6480 Fax +64 802 4432 Ph +61 8 8947 8300 Ph +61 3 8551 -
Graham Park Sewage Pumping Station and Force Main Improvement Project
Graham Park Sewage Pumping Station and Force Main Improvements Project Number: SPS112 Project Summary Project Commencement: Anticipated Start of Construction - Spring 2019 Project Description: Replacement of an existing antiquated Sewage Pumping Station (SPS) and force main (FM), and raise the SPS control building and equipment above the 100-year flood plain elevation. Scope of Work: This project will consist of installing a new submersible SPS with new controls, motors, emergency generator, by-pass connection on FM, and new flow metering equipment. The proposed pump control enclosure will be about 12’ in height and will be approximately 7’ by 13’ in size consisting of a faux-brick façade. The facility will be enclosed with an 8’ high chain-link fence with barbed-wire and locked for security. Additionally, the project will provide emergency backup supply and protect pump station facilities from storm surge flooding. Project benefits: The project will improve service reliability, safety conditions, and provide permanent back-up power. Project impact on residents/customers Noise associated with construction. Construction trucks accessing the SPS. Daily cleanup during construction to remove dust and dirt. Potential impact on traffic: Our standard roadway and traffic matters are outlined below. The Construction Contractor will be required to comply with Department of Environmental Quality (DEQ) Erosion and Sediment Control requirements to ensure all construction traffic does not track dirt on roads. The Service Authority will include in the construction contract a provision for fees to be assessed if the Construction Contractor does not comply with these requirements. Regular project updates to the impact of traffic will be listed on the website Graham Park Project. -
Sewer Overflow Response Plan
DAPHNE UTILITIES SANITARY SEWER OVERFLOW RESPONSE PLAN RECORD OF PLAN REVISIONS REVISION SECTIONS INITIALS REMARKS DATE REVISED 12/15/18 All Draft Plan Created 03/15/19 All Original Plan Published Table of Contents I. Purpose ..................................................................................................................................... 1 II. General ....................................................................................................................................... 1 III. Objectives .................................................................................................................................. 1 IV. System Information .................................................................................................................... 1 V. SSO and Surface Water Assessment .......................................................................................... 2 VI. Sanitary Sewer Overflow Response Procedures ........................................................................ 2 A. Notification of Possible SSO ........................................................................................ 3 B. Dispatch of Appropriate Crews to Site of Sewer Overflow.......................................... 3 C. Overflow Correction, Containment, and Clean Up ...................................................... 4 1. Responsibilities of Response Crew upon Arrival............................................... 4 2. Initial Measures for Containment...................................................................... -
Pump Station Design Guidelines – Second Edition
Pump Station Design Guidelines – Second Edition Jensen Engineered Systems 825 Steneri Way Sparks, NV 89431 For design assistance call (855)468-5600 ©2012 Jensen Precast JensenEngineeredSystems.com TABLE OF CONTENTS INTRODUCTION ............................................................................................................................................................. 3 PURPOSE OF THIS GUIDE ........................................................................................................................................... 3 OVERVIEW OF A TYPICAL JES SUBMERSIBLE LIFT STATION ....................................................................................... 3 DESIGN PROCESS ....................................................................................................................................................... 3 BASIC PUMP SELECTION ............................................................................................................................................... 5 THE SYSTEM CURVE ................................................................................................................................................... 5 STATIC LOSSES....................................................................................................................................................... 5 FRICTION LOSSES .................................................................................................................................................. 6 TOTAL DYNAMIC HEAD ........................................................................................................................................ -
Sanitary Sewer Overflow Corrective Action Plan/Engineering Report
FAYETTEVILLE PUBLIC UTILITIES WATER AND SEWER DEPARTMENT SANITARY SEWER OVERFLOW CORRECTIVE ACTION PLAN ENGINEERING REPORT 408 College Street, West Fayetteville, TN 37334 (931)433-1522 CONSOLIDATED TECHNOLOGIES, INC. Engineers in Water and Earth Sciences Nashville, Tennessee TABLE OF CONTENTS Page 1 INTRODUCTION 1.1 Background and Purpose Scope 2 EXISTING SEWER SYSTEM 2.1 Gravity Sewers 2.2 Pumping Stations 2.2 Wastewater Treatment Plant 2.3 3 EXISTING WASTEWATER TREATMENT PLANT 3.1 Plant Design Data 3.2 Influent Pump Station 3.2 Headworks 3.2 Aeration Basins 3.3 Secondary Clarifiers 3.3 Return Sludge Pump Station 3.3 Disinfection Facilities 3.4 Sludge Digestion and Holding Facilities 3.4 Sludge Disposal Site 3.4 Drying Beds 3.5 Staff 3.5 Operating Review 3.5 4 PREVIOUS SEWER SYSTEM OVERFLOWS (SSO’s) 4.1 Existing Problems 4.2 5 EXISTING AND FUTURE SEWER FLOWS 5.1 Flow Measurement Data 5.2 Projection of Future Flows 5.4 6 PLAN FOR I/I REDUCTION AND ELIMINATION OF SSO’s 6.1 New Construction Sewer System Rehabilitation 7 RECOMMENDED CAPITAL IMPROVEMENTS 7.1 Projects Currently Under Design/Construction 7.2 Projects Planned for Construction 7.3 Project Schedule 7.6 Project Maps LIST OF TABLES 2.1 Pump Station Information 2.3 3.1 Discharge Monitoring Reports Summary 3.5 4.1 Overflows/Bypasses 4.2 5.1 Flow Monitoring Sites 5.2 TABLE OF CONTENTS (Continued) LIST OF TABLES (Continued) Page 5.2 Historical Sewer and Water Customers 5.4 5.3 Future Flow Projections 5.5 7.1 Project Schedule 7.6 Follows Page LIST OF FIGURES 2.1 General Map 2.2 3.1 Site -
Parks and Recreation Master Plan
2017-2021 FEBRUARY 28, 2017 Parks and Recreation Master Plan 2017-2021 Parks and Recreation Master Plan City of Southfi eld, Michigan Prepared by: McKenna Associates Community Planning and Design 235 East Main Street, Suite 105 Northville, Michigan 48167 tel: (248) 596-0920 fax: (248) 596-.0930 www.mcka.com ACKNOWLEDGMENTS The mission of the Southfi eld Parks and Recreation Department is to provide excellence and equal opportunity in leisure, cultural and recreational services to all of the residents of Southfi eld. Our purpose is to provide safe, educationally enriching, convenient leisure opportunities, utilizing public open space and quality leisure facilities to enhance the quality of life for Southfi eld’s total population. Administration Staff Parks and Recreation Board Terry Fields — Director, Parks & Recreation Department Rosemerry Allen Doug Block — Manager, P&R Administration Monica Fischman Stephanie Kaiser — Marketing Analyst Brandon Gray Michael A. Manion — Community Relations Director Jeannine Reese Taneisha Springer — Customer Service Ronald Roberts Amani Johnson – Student Representative Facility Supervisors Planning Department Pattie Dearie — Facility Supervisor, Beech Woods Recreation Center Terry Croad, AICP, ASLA — Director of Planning Nicole Messina — Senior Adult Facility Coordinator Jeff Spence — Assistant City Planner Jonathon Rahn — Facility Supervisor, Southfi eld Pavilion, Sarah K. Mulally, AICP — Assistant City Planner P&R Building and Burgh Park Noreen Kozlowski — Landscape Design Coordinator Golf Planning Commission Terri Anthony-Ryan — Head PGA Professional Donald Culpepper – Chairman Dan Bostick — Head Groundskeeper Steven Huntington – Vice Chairman Kathy Haag — League Information Robert Willis – Secretary Dr. LaTina Denson Parks/Park Services Staff Jeremy Griffi s Kost Kapchonick — Park Services, Park Operations Carol Peoples-Foster Linnie Taylor Parks Staff Dennis Carroll Elected Offi cials & City Administration Joel Chapman The Honorable Kenson J. -
Construction of Submersible Sewage Pumping Stations
STS402 Hunter Water Corporation A.B.N. 46 228 513 446 Standard Technical Specification for: CONSTRUCTION OF SUBMERSIBLE SEWAGE PUMPING STATIONS This Standard Technical Specification was developed by Hunter Water to be used for the construction and/or maintenance of water and/or sewerage works that are, or are to become, the property of Hunter Water. It is intended that this Standard Technical Specification be used in conjunction with various other standard and project specific drawings and design requirements as defined by Hunter Water for each particular project. Hunter Water does not consider this Standard Technical Specification suitable for use for any other purpose or in any other manner. Use of this Standard Technical Specification for any other purpose or in any other manner is wholly at the user's risk. Hunter Water makes no representations or warranty that this Standard Technical Specification has been prepared with reasonable care and does not assume a duty of care to any person using this document for any purpose other than stated. In the case of this document having been downloaded from Hunter Water's website; - Hunter Water has no responsibility to inform you of any matter relating to the accuracy of this Standard Technical Specification which is known to Hunter Water at the time of downloading or subsequently comes to the attention of Hunter Water. - This document is current at the date of downloading. Hunter Water may update this document at any time. Copyright in this document belongs to Hunter Water Corporation. Hunter Water Corporation A.B.N. 46 228 513 446 CONTENTS 1. -
Sanitary Sewer & Pumping Station Manual
SANITARY SEWER AND PUMPING STATION MANUAL FOR SPRINGFIELD WATER AND SEWER COMMISSION Last Revised: _July 20, 2017______________ Page 1 TABLE OF CONTENTS Title Section Number General 1 Drawing Requirements 2 Construction Procedures 3 Flow Determination 4 Computer Modeling 5 Sanitary Sewers 6 Pump Stations 7 Appendices A – Checklist B – Construction Specifications C – Standard Drawings Page 2 SECTION 1 – GENERAL 1.1 General................................................................ 4 1.2 Purpose................................................................ 4 1.3 Structure of the Manual................................................ 4 1.4 Definitions............................................................ 4 1.5 References............................................................. 9 Page 3 1.1 General The Sanitary Sewer and Pumping Station Manual is for the design and construction of infrastructure. The specific subjects of these manuals are: • Procedures Manual for Infrastructure Development • Sanitary Sewer and Pumping Station • Structures • Geotechnical • Construction Inspection 1.2 Purpose The purpose of this manual is to provide information regarding design and construction requirements for sanitary sewers, pumping stations, and force mains in Springfield, Kentucky. The goal is to provide uniform design and construction standards. The end result will be public infrastructure that is cost effective and maintainable by the Springfield Water and Sewer Commission (SWSC)in the long term. 1.3 Structure of the Manual The manual -
Detroit Audubon's 2017 Earth Day
A publication of Detroit Audubon • www.detroitaudubon.org Spring 2017 • Vol. 2017, Issue 1 DETROIT AUDUBON’S 2017 EARTH DAY CELEBRATION/TEACH-IN - “SOARING TO NEW HEIGHTS!” Celebrate the 47th Earth Day, Saturday, April 22 at the Downriver Campus Wayne County Community College, 21000 Northline Rd., Taylor, MI In collaboration with the Continuing Education Department at Wayne County Julie Beutel, folksinger and peace and justice activist, is well known Community College District, Detroit Audubon presents the annual Earth Day locally for singing at many peace and justice rallies. She produces Celebration and Teach-In April 22, to help educate the community about the concerts for other local musicians, hosting house concerts in Detroit. environment and celebrate our precious planet. Presentations and events include. She has a rich and expressive voice. She is also an accomplished Don Sherwood M.S., retired Community College Professor of actress, including playing Clara Ford in the opera, “The Forgotten,” Biology and Downriver resident, is a lifelong birder with experience narrating documentaries, and doing other voiceover work. She is fluent in Spanish, as an assistant bird bander and raptor rehabilitator. Presently he is having lived in Spain for one year and Nicaragua for two years. She has performed a volunteer counter with the U.S. Fish and Wildlife Service’s annual at other Detroit Audubon conferences, most recently at the Detroit Zoo. Detroit River Hawkwatch at Lake Erie Metropark. Sherwood knows the Joe Rogers received a biology degree from Central Michigan University, and spent flora and fauna surrounding the WCCC Downriver Campus, where he has observed many years in the field studying raptors, including nest studies of Bald Eagles, over 130 bird species over three decades. -
Eliza Howell Park and ROUGE Park LOLA Valley, Venoy Park
TRANSFORMING THE ROUGE AOC FROM MOWED DOWN TO GROWN UP Authors: zachare ball and tonya hunter, Environmental Consulting & Technology, Inc. grow zone restoration and Benefits and results in Project background wetland Restoration installation the rouge river aoc The Alliance of Rouge Communities (ARC), a 501(c)(3) organization, is a • Increased focus on the benefits of native areas voluntary public watershed entity currently comprised of 34 municipal Valley Woods wetland Eliza Howell Park and Rouge Park and habitat. A Detroit Public Schools program governments (i.e. cities, townships and villages), three counties by a local stewardship group expanded from two The Valley Woods wetland is located within the City of Southfield and is bounded by Eliza Howell Park and Rouge Park in the City of Detroit protect a floodplain and riparian (Wayne, Oakland and Washtenaw), Henry Ford Community College, classrooms to 10 classrooms in Detroit’s Rouge Park commercial and residential development and the Rouge River. Valley Woods is recognized for corridor that is undisturbed except for streambanks that have been altered by excessive flows. University of Michigan-Dearborn, Wayne County Airport Authority and since the prairie was restored in 2012. Students visit its state-significant plant community and has a floodplain plant community that is slightly Rouge Park is the City of Detroit’s largest park at 1,181 acres and includes 6.13 linear miles six cooperating partners (i.e. other organizations) as authorized by the restored prairie throughout the school year to better than average undeveloped land within the state. Many pre-settlement species and plant of the Rouge River’s Main Branch. -
Evaluation of Sanitary Sewer Overflows and Unpermitted Discharges Associated with Hurricanes Hermine & Matthew
EVALUATION OF SANITARY SEWER OVERFLOWS AND UNPERMITTED DISCHARGES ASSOCIATED WITH HURRICANES HERMINE & MATTHEW JANUARY 6, 2017 THIS PAGE WAS LEFT BLANK INTENTIONALLY EVALUATION OF SANITARY SEWER OVERFLOWS AND UNPERMITTED DISCHARGES ASSOCIATED WITH HURRICANES HERMINE & MATTHEW Financial Project No.: January 6, 2017 PR9792143-V2 RS&H No.: 302-0032-000 Prepared by RS&H, Inc. at the direction of the Florida Department of Environmental Protection ii THIS PAGE WAS LEFT BLANK INTENTIONALLY TABLE OF CONTENTS Chapter 1 INTRODUCTION ............................................................................................................................................................... 1 1.1 SCOPE OF THE EVALUATIONS..................................................................................................................................... 1 1.2 METHODOLOGY ............................................................................................................................................................... 2 1.3 DOCUMENT OVERVIEW ................................................................................................................................................ 2 Chapter 2 STORMWATER AND WATER LEVEL ANALYSIS .................................................................................................... 3 2.1 PRECIPITATION DATA .................................................................................................................................................... 3 2.1.1 Hurricane Hermine ...................................................................................................................................................