Capnographs/Pulse Oximeters V9004 Series Intelligent Capnography and More
Total Page:16
File Type:pdf, Size:1020Kb
Capnographs/Pulse Oximeters V9004 Series Intelligent Capnography and More • Sampling rate of 120 ml/min • High resolution vacuum fluorescent display Previous • Simplified menu structure • Monitoring of both intubated and non-intubated patients • Flexibility to incorporate SpO2 and FiO2 Next • Patented moisture removal system • Sidestream monitor not suitable for rodents Table of Contents The V9004 is a versatile Table Top capnograph with a graphical vac- Specifications uum fluorescent display which can be ordered with either pulse oximetry, or pulse oximetry and fractional inspired oxygen, FiO . Display: 2 Displayed Trends Graphical display, factory selectable sample rate, Available parameters (CO2 or CO2 and SpO2 plethysmogram) can be user selectable trend Product displayed as waveforms or trends. In addition to waveforms, the Displayed 15 hr display at 12 sec sample rate Index V9004 also displays an average of ETCO2, respiration rate and when Waveforms 9 hr display at 4 sec sample rate, Selectable CO2 or CO2 /Plethysmogram waveform available % SpO2, heart rate and % O2. CO2: Four user-selectable averaging modes are available for oximetry, along Measurement Non-Dispersive IR absorption with numeric and audible alarms for high and low values of all measured Measurement Range 0 to 10% CO2 Search parameters. Low priority alarms warn the user of system setup malfunc- Units User-selectable: mmHg Vol. %, kPa tions such as a disconnected probe. The audible indicators and alarms Display Range 0 to 100 mmHg or 0 to 10.0% CO2 or 0 to 13.3 kPa Accuracy ±2 mmHg; ±0.3%; ±0.3 kPa, or 4% of reading, vary in rate and pitch to indicate changes in pulse rate and SpO2 level. whichever is greater (0 to 10% CO2) The V9004 Table Top capnograph comes complete with an instruction Resolution 1 mmHg; 0.1%; 0.1 kPa manual, AC adapter/charger, and the animal attachment kit, BS4 72- N2O Compensation User-selectable 40% (default = OFF) Averaging 4-breath average Home 3232. When ordered with oximetry the system also includes a 5 foot Oximeter Extension cable, BS4 72-3157, small reflectance probe, BS4 Respiration Rate: 72-3254, and the small to medium Y-Clip probe BS4 72-3256 are Range 0 to 150 ±1 bpm Averaging 4-breath average included. The FiO2 T-Adapter, BS4 72-3138, and the FiO2 sensor, BS4 SpO (Optional): 72-3139, and cable, BS4 72-3140, are included when the V9004 is 2 Range 0 to 100% Contact ordered with FiO2. A gas calibration kit and other airway accessories are available, see below. A graphics printer, BS4 72-3279, is available Accuracy ±2% at 70 to 100%; ±3% at 50 to 69% Us Averaging 4, 8, 16 beat, user-selectable to printout displayed waveforms from the V9004. The AC adapter for the graphics printer is not included but is recommended. The Pulse Rate (Optional): Range 20 to 350 bpm PC/Printer Interface Cable, BS4 72-3179, is used to export data to a PC Accuracy ±1 beat or 2% whichever is greater ™ running Windows 95 or higher. Averaging 8 or 16 seconds, user-selectable Pulse Tone Pitch corresponds to SpO2 value, Volume adjustable or OFF FiO (Optional): Previous Catalog No. $ Product 2 BS4 72-3240 3,358.00 Table Top Capnograph, 110 VAC, 60 Hz Range 0 to 100% Accuracy ±2% BS4 72-3276 4,428.00 Table Top Capnograph, 220 VAC, 50 Hz Response Time < 10 sec. to 90% BS4 72-3241 4,344.00 TT Capnograph and Oximeter, 110 VAC, 60 Hz Drift < 2% full scale per month Next BS4 72-3277 5,203.00 TT Capnograph and Oximeter, 220 VAC, 50 Hz Battery Requirements Nickel Cadmium battery, 6 VDC, internal rechargeable, not BS4 72-3242 4,589.00 TT Capnograph, Oximeter and FiO , 110 VAC, 60 Hz replaceable, fully charged continuous - use life 2 hours approxi- 2 mate, maximum full charge time 4 hours BS4 72-3278 5,471.00 TT Capnograph, Oximeter and FiO , 220 VAC, 50 Hz 2 Serial Output RS232C: tabular trends, patient data Capnograph Accessories1 Analog Output Any three of : CO2 waveform, Plethysmogram, End Tidal CO2 BS4 72-3138 121.00 Adapter T, FiO2 Respiration Rate, Inspired CO2, % SpO2, Pulse Rate Fractional Inspired Oxygen, 0V or 1V Cal signal, Range 0 to 1 VDC full scale BS4 72-3139 194.00 FiO2 Sensor Safety Approvals Designed to meet IEC 601-1, CSA 125, UL 544, and BS4 72-3140 75.00 FiO2 Sensor Cable IEC 601-1-2 (EMC CE), ISO 9001 Certified 2 Other Accessories Dimensions, H x W x D 88.9 x 254 x 139.7 mm (3.5 x 10.0 x 5.5 in) BS4 72-3279 1,103.00 V3408 Graphics Printer and Cable Weight 2.27 kg (5 lbs) BS4 72-3214 129.00 AC Adapter/Charger, 110 VAC, 60 Hz BS4 72-3215 151.00 AC Adapter/Charger, 208 to 252 VAC, 50 Hz BS4 72-3205 48.00 Printer Paper, pkg. of 4 BS4 72-3179 121.00 PC/Printer Interface Cable BS4 72-3175 187.00 IV Pole Bracket 11,000 Specialty Products to Enhance Your Bioresearch F44 U.S. Toll Free: (800) 272-2775 • Fax: (508) 429-5732 • Online: www.harvardapparatus.com.