IBM Power Systems S922, S914, and S924 Technical Overview and Introduction Front cover IBM Power Systems S922, S914, and S924 Technical Overview and Introduction Young Hoon Cho Gareth Coates Bartlomiej Grabowski Volker Haug Redpaper International Technical Support Organization IBM Power Systems S922, S914, and S924: Technical Overview and Introduction July 2018 REDP-5497-00 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. First Edition (July 2018) This edition applies to IBM Power Systems S922, S914, and S924, machine types and model numbers 9009-22A, 9009-41A, and 9009-42A. © Copyright International Business Machines Corporation 2018. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . vii Trademarks . viii Preface . ix Authors. ix Now you can become a published author, too! . .x Comments welcome. xi Stay connected to IBM Redbooks . xi Chapter 1. General description . 1 1.1 Systems overview . 2 1.1.1 Power S922 server . 2 1.1.2 Power S914 server . 3 1.1.3 Power S924 server . 4 1.1.4 Common features . 5 1.2 Operating environment . 6 1.3 Physical package . 8 1.3.1 Tower model . 8 1.3.2 Rack-mount model . 8 1.4 System features . 9 1.4.1 Power S922 server features . 9 1.4.2 Power S914 server features . 10 1.4.3 Power S924 server features . 11 1.4.4 Minimum features . 13 1.4.5 Power supply features . 13 1.4.6 Processor module features . 14 1.4.7 Memory features . 17 1.4.8 Peripheral Component Interconnect Express slots. 18 1.5 Disk and media features . 18 1.6 I/O drawers for Power S922, Power S914, and Power S924 servers. 31 1.6.1 PCIe Gen3 I/O expansion drawer . 31 1.6.2 I/O drawers and usable PCI slots . 33 1.6.3 EXP24SX (#ESLS) and EXP12SX (#ESLL) SAS Storage Enclosures. 35 1.7 IBM i Solution Editions for Power S914 . 36 1.8 IBM Capacity BackUp . 37 1.8.1 Power S922 (9009-22A) IBM Capacity BackUp offering. 37 1.8.2 Power S914 (9009-41A) IBM Capacity BackUp offering. 38 1.8.3 Power S924 (9009-42A) IBM Capacity BackUp offering. 40 1.9 System racks. 41 1.9.1 IBM 7014 Model T00 rack. 42 1.9.2 IBM 7014 Model T42 rack. 43 1.9.3 IBM 42U Slim Rack 7965-94Y . 44 1.9.4 1.8 Meter Rack (#0551) . 44 1.9.5 2.0 Meter Rack (#0553) . 45 1.9.6 Rack (#ER05) . 45 1.9.7 The AC power distribution unit and rack content . 45 1.9.8 Rack-mounting rules . 49 1.9.9 Useful rack additions. 49 1.9.10 Original equipment manufacturer racks . 52 © Copyright IBM Corp. 2018. All rights reserved. iii 1.10 Hardware Management Console . 53 1.10.1 New features. 53 1.10.2 Hardware Management Console overview . 53 1.10.3 Hardware Management Console code level . 55 1.10.4 Two architectures of Hardware Management Console. 55 1.10.5 Hardware Management Console connectivity to POWER9 processor-based systems. 56 1.10.6 High availability Hardware Management Console configuration. 57 Chapter 2. Architecture and technical overview . 59 2.1 The IBM POWER9 processor . 63 2.1.1 POWER9 processor overview. 63 2.1.2 POWER9 processor features . 64 2.1.3 POWER9 processor core . 64 2.1.4 Simultaneous multithreading. 65 2.1.5 Processor feature codes . 66 2.1.6 Memory access. 67 2.1.7 On-chip L3 cache innovation and intelligent caching . 68 2.1.8 Hardware transactional memory . 69 2.1.9 Coherent Accelerator Processor Interface 2.0 . 69 2.1.10 Power management and system performance . 71 2.1.11 Comparison of the POWER9, POWER8, and POWER7+ processors . 71 2.2 Memory subsystem . 72 2.2.1 Memory placement rules. 73 2.2.2 Memory bandwidth . 77 2.3 System bus . 80 2.4 Internal I/O subsystem . 81 2.4.1 Slot configuration . 81 2.4.2 System ports . ..
Recommended publications
  • Investigations on Hardware Compression of IBM Power9 Processors
    Investigations on hardware compression of IBM Power9 processors Jérome Kieffer, Pierre Paleo, Antoine Roux, Benoît Rousselle Outline ● The bandwidth issue at synchrotrons sources ● Presentation of the evaluated systems: – Intel Xeon vs IBM Power9 – Benchmarks on bandwidth ● The need for compression of scientific data – Compression as part of HDF5 – The hardware compression engine NX-gzip within Power9 – Gzip performance benchmark – Bitshuffle-LZ4 benchmark – Filter optimizations – Benchmark of parallel filtered gzip ● Conclusions – on the hardware – on the compression pipeline in HDF5 Page 2 HDF5 on Power9 18/09/2019 Bandwidth issue at synchrotrons sources Data analysis computer with the main interconnections and their associated bandwidth. Data reduction Upgrade to → Azimuthal integration 100 Gbit/s Data compression ! Figures from former generation of servers Kieffer et al. Volume 25 | Part 2 | March 2018 | Pages 612–617 | 10.1107/S1600577518000607 Page 3 HDF5 on Power9 18/09/2019 Topologies of Intel Xeon servers in 2019 Source: intel.com Page 4 HDF5 on Power9 18/09/2019 Architecture of the AC922 server from IBM featuring Power9 Credit: Thibaud Besson, IBM France Page 6 HDF5 on Power9 18/09/2019 Bandwidth measurement: Xeon vs Power9 Computer Dell R840 IBM AC922 Processor 4 Intel Xeon (12 cores) 2 IBM Power9 (16 cores) 2.6 GHz 2.7 GHz Cache (L3) 19 MB 8x 10 MB Memory channels 4x 6 DDR4 2x 8 DDR4 Memory capacity → 3TB → 2TB Memory speed theory 512 GB/s 340 GB/s Measured memory speed 160 GB/s 270 GB/s Interconnects PCIe v3 PCIe v4 NVlink2 & CAPI2 GP-GPU co-processor 2Tesla V100 PCIe v3 2Tesla V100 NVlink2 Interconnect speed 12 GB/s 48 GB/s CPU ↔ GPU Page 8 HDF5 on Power9 18/09/2019 Strength and weaknesses of the OpenPower architecture While amd64 is today’s de facto standard in HPC, it has a few competitors: arm64, ppc64le and to a less extend riscv and mips64.
    [Show full text]
  • VIA RAID Configurations
    VIA RAID configurations The motherboard includes a high performance IDE RAID controller integrated in the VIA VT8237R southbridge chipset. It supports RAID 0, RAID 1 and JBOD with two independent Serial ATA channels. RAID 0 (called Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup. RAID 1 (called Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive. JBOD (Spanning) stands for Just a Bunch of Disks and refers to hard disk drives that are not yet configured as a RAID set. This configuration stores the same data redundantly on multiple disks that appear as a single disk on the operating system. Spanning does not deliver any advantage over using separate disks independently and does not provide fault tolerance or other RAID performance benefits. If you use either Windows® XP or Windows® 2000 operating system (OS), copy first the RAID driver from the support CD to a floppy disk before creating RAID configurations.
    [Show full text]
  • D:\Documents and Settings\Steph
    P45D3 Platinum Series MS-7513 (v1.X) Mainboard G52-75131X1 i Copyright Notice The material in this document is the intellectual property of MICRO-STAR INTERNATIONAL. We take every care in the preparation of this document, but no guarantee is given as to the correctness of its contents. Our products are under continual improvement and we reserve the right to make changes without notice. Trademarks All trademarks are the properties of their respective owners. NVIDIA, the NVIDIA logo, DualNet, and nForce are registered trademarks or trade- marks of NVIDIA Corporation in the United States and/or other countries. AMD, Athlon™, Athlon™ XP, Thoroughbred™, and Duron™ are registered trade- marks of AMD Corporation. Intel® and Pentium® are registered trademarks of Intel Corporation. PS/2 and OS®/2 are registered trademarks of International Business Machines Corporation. Windows® 95/98/2000/NT/XP/Vista are registered trademarks of Microsoft Corporation. Netware® is a registered trademark of Novell, Inc. Award® is a registered trademark of Phoenix Technologies Ltd. AMI® is a registered trademark of American Megatrends Inc. Revision History Revision Revision History Date V1.0 First release for PCB 1.X March 2008 (P45D3 Platinum) Technical Support If a problem arises with your system and no solution can be obtained from the user’s manual, please contact your place of purchase or local distributor. Alternatively, please try the following help resources for further guidance. Visit the MSI website for FAQ, technical guide, BIOS updates, driver updates, and other information: http://global.msi.com.tw/index.php? func=faqIndex Contact our technical staff at: http://support.msi.com.tw/ ii Safety Instructions 1.
    [Show full text]
  • Designing Disk Arrays for High Data Reliability
    Designing Disk Arrays for High Data Reliability Garth A. Gibson School of Computer Science Carnegie Mellon University 5000 Forbes Ave., Pittsbugh PA 15213 David A. Patterson Computer Science Division Electrical Engineering and Computer Sciences University of California at Berkeley Berkeley, CA 94720 hhhhhhhhhhhhhhhhhhhhhhhhhhhhh This research was funded by NSF grant MIP-8715235, NASA/DARPA grant NAG 2-591, a Computer Measurement Group fellowship, and an IBM predoctoral fellowship. 1 Proposed running head: Designing Disk Arrays for High Data Reliability Please forward communication to: Garth A. Gibson School of Computer Science Carnegie Mellon University 5000 Forbes Ave. Pittsburgh PA 15213-3890 412-268-5890 FAX 412-681-5739 [email protected] ABSTRACT Redundancy based on a parity encoding has been proposed for insuring that disk arrays provide highly reliable data. Parity-based redundancy will tolerate many independent and dependent disk failures (shared support hardware) without on-line spare disks and many more such failures with on-line spare disks. This paper explores the design of reliable, redundant disk arrays. In the context of a 70 disk strawman array, it presents and applies analytic and simulation models for the time until data is lost. It shows how to balance requirements for high data reliability against the overhead cost of redundant data, on-line spares, and on-site repair personnel in terms of an array's architecture, its component reliabilities, and its repair policies. 2 Recent advances in computing speeds can be matched by the I/O performance afforded by parallelism in striped disk arrays [12, 13, 24]. Arrays of small disks further utilize advances in the technology of the magnetic recording industry to provide cost-effective I/O systems based on disk striping [19].
    [Show full text]
  • Disk Array Data Organizations and RAID
    Guest Lecture for 15-440 Disk Array Data Organizations and RAID October 2010, Greg Ganger © 1 Plan for today Why have multiple disks? Storage capacity, performance capacity, reliability Load distribution problem and approaches disk striping Fault tolerance replication parity-based protection “RAID” and the Disk Array Matrix Rebuild October 2010, Greg Ganger © 2 Why multi-disk systems? A single storage device may not provide enough storage capacity, performance capacity, reliability So, what is the simplest arrangement? October 2010, Greg Ganger © 3 Just a bunch of disks (JBOD) A0 B0 C0 D0 A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 C3 D3 Yes, it’s a goofy name industry really does sell “JBOD enclosures” October 2010, Greg Ganger © 4 Disk Subsystem Load Balancing I/O requests are almost never evenly distributed Some data is requested more than other data Depends on the apps, usage, time, … October 2010, Greg Ganger © 5 Disk Subsystem Load Balancing I/O requests are almost never evenly distributed Some data is requested more than other data Depends on the apps, usage, time, … What is the right data-to-disk assignment policy? Common approach: Fixed data placement Your data is on disk X, period! For good reasons too: you bought it or you’re paying more … Fancy: Dynamic data placement If some of your files are accessed a lot, the admin (or even system) may separate the “hot” files across multiple disks In this scenario, entire files systems (or even files) are manually moved by the system admin to specific disks October 2010, Greg
    [Show full text]
  • Identify Storage Technologies and Understand RAID
    LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals IdentifyIdentify StorageStorage TechnologiesTechnologies andand UnderstandUnderstand RAIDRAID LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Lesson Overview In this lesson, you will learn: Local storage options Network storage options Redundant Array of Independent Disk (RAID) options LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Anticipatory Set List three different RAID configurations. Which of these three bus types has the fastest transfer speed? o Parallel ATA (PATA) o Serial ATA (SATA) o USB 2.0 LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options Local storage options can range from a simple single disk to a Redundant Array of Independent Disks (RAID). Local storage options can be broken down into bus types: o Serial Advanced Technology Attachment (SATA) o Integrated Drive Electronics (IDE, now called Parallel ATA or PATA) o Small Computer System Interface (SCSI) o Serial Attached SCSI (SAS) LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options SATA drives have taken the place of the tradition PATA drives. SATA have several advantages over PATA: o Reduced cable bulk and cost o Faster and more efficient data transfer o Hot-swapping technology LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options (continued) SAS drives have taken the place of the traditional SCSI and Ultra SCSI drives in server class machines. SAS have several
    [Show full text]
  • POWER® Processor-Based Systems
    IBM® Power® Systems RAS Introduction to IBM® Power® Reliability, Availability, and Serviceability for POWER9® processor-based systems using IBM PowerVM™ With Updates covering the latest 4+ Socket Power10 processor-based systems IBM Systems Group Daniel Henderson, Irving Baysah Trademarks, Copyrights, Notices and Acknowledgements Trademarks IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. These and other IBM trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: Active AIX® POWER® POWER Power Power Systems Memory™ Hypervisor™ Systems™ Software™ Power® POWER POWER7 POWER8™ POWER® PowerLinux™ 7® +™ POWER® PowerHA® POWER6 ® PowerVM System System PowerVC™ POWER Power Architecture™ ® x® z® Hypervisor™ Additional Trademarks may be identified in the body of this document. Other company, product, or service names may be trademarks or service marks of others. Notices The last page of this document contains copyright information, important notices, and other information. Acknowledgements While this whitepaper has two principal authors/editors it is the culmination of the work of a number of different subject matter experts within IBM who contributed ideas, detailed technical information, and the occasional photograph and section of description.
    [Show full text]
  • IBM Power Systems Performance Report Apr 13, 2021
    IBM Power Performance Report Power7 to Power10 September 8, 2021 Table of Contents 3 Introduction to Performance of IBM UNIX, IBM i, and Linux Operating System Servers 4 Section 1 – SPEC® CPU Benchmark Performance 4 Section 1a – Linux Multi-user SPEC® CPU2017 Performance (Power10) 4 Section 1b – Linux Multi-user SPEC® CPU2017 Performance (Power9) 4 Section 1c – AIX Multi-user SPEC® CPU2006 Performance (Power7, Power7+, Power8) 5 Section 1d – Linux Multi-user SPEC® CPU2006 Performance (Power7, Power7+, Power8) 6 Section 2 – AIX Multi-user Performance (rPerf) 6 Section 2a – AIX Multi-user Performance (Power8, Power9 and Power10) 9 Section 2b – AIX Multi-user Performance (Power9) in Non-default Processor Power Mode Setting 9 Section 2c – AIX Multi-user Performance (Power7 and Power7+) 13 Section 2d – AIX Capacity Upgrade on Demand Relative Performance Guidelines (Power8) 15 Section 2e – AIX Capacity Upgrade on Demand Relative Performance Guidelines (Power7 and Power7+) 20 Section 3 – CPW Benchmark Performance 19 Section 3a – CPW Benchmark Performance (Power8, Power9 and Power10) 22 Section 3b – CPW Benchmark Performance (Power7 and Power7+) 25 Section 4 – SPECjbb®2015 Benchmark Performance 25 Section 4a – SPECjbb®2015 Benchmark Performance (Power9) 25 Section 4b – SPECjbb®2015 Benchmark Performance (Power8) 25 Section 5 – AIX SAP® Standard Application Benchmark Performance 25 Section 5a – SAP® Sales and Distribution (SD) 2-Tier – AIX (Power7 to Power8) 26 Section 5b – SAP® Sales and Distribution (SD) 2-Tier – Linux on Power (Power7 to Power7+)
    [Show full text]
  • Towards a Portable Hierarchical View of Distributed Shared Memory Systems: Challenges and Solutions
    Towards A Portable Hierarchical View of Distributed Shared Memory Systems: Challenges and Solutions Millad Ghane Sunita Chandrasekaran Margaret S. Cheung Department of Computer Science Department of Computer and Information Physics Department University of Houston Sciences University of Houston TX, USA University of Delaware Center for Theoretical Biological Physics, [email protected],[email protected] DE, USA Rice University [email protected] TX, USA [email protected] Abstract 1 Introduction An ever-growing diversity in the architecture of modern super- Heterogeneity has become increasingly prevalent in the recent computers has led to challenges in developing scientifc software. years given its promising role in tackling energy and power con- Utilizing heterogeneous and disruptive architectures (e.g., of-chip sumption crisis of high-performance computing (HPC) systems [15, and, in the near future, on-chip accelerators) has increased the soft- 20]. Dennard scaling [14] has instigated the adaptation of heteroge- ware complexity and worsened its maintainability. To that end, we neous architectures in the design of supercomputers and clusters need a productive software ecosystem that improves the usability by the HPC community. The July 2019 TOP500 [36] report shows and portability of applications for such systems while allowing how 126 systems in the list are heterogeneous systems confgured every parallelism opportunity to be exploited. with one or many GPUs. This is the prevailing trend in current gen- In this paper, we outline several challenges that we encountered eration of supercomputers. As an example, Summit [31], the fastest in the implementation of Gecko, a hierarchical model for distributed supercomputer according to the Top500 list (June 2019) [36], has shared memory architectures, using a directive-based program- two IBM POWER9 processors and six NVIDIA Volta V100 GPUs.
    [Show full text]
  • Power Architecture® ISA 2.06 Stride N Prefetch Engines to Boost Application's Performance
    Power Architecture® ISA 2.06 Stride N prefetch Engines to boost Application's performance History of IBM POWER architecture: POWER stands for Performance Optimization with Enhanced RISC. Power architecture is synonymous with performance. Introduced by IBM in 1991, POWER1 was a superscalar design that implemented register renaming andout-of-order execution. In Power2, additional FP unit and caches were added to boost performance. In 1996 IBM released successor of the POWER2 called P2SC (POWER2 Super chip), which is a single chip implementation of POWER2. P2SC is used to power the 30-node IBM Deep Blue supercomputer that beat world Chess Champion Garry Kasparov at chess in 1997. Power3, first 64 bit SMP, featured a data prefetch engine, non-blocking interleaved data cache, dual floating point execution units, and many other goodies. Power3 also unified the PowerPC and POWER Instruction set and was used in IBM's RS/6000 servers. The POWER3-II reimplemented POWER3 using copper interconnects, delivering double the performance at about the same price. Power4 was the first Gigahertz dual core processor launched in 2001 which was awarded the MicroProcessor Technology Award in recognition of its innovations and technology exploitation. Power5 came in with symmetric multi threading (SMT) feature to further increase application's performance. In 2004, IBM with 15 other companies founded Power.org. Power.org released the Power ISA v2.03 in September 2006, Power ISA v.2.04 in June 2007 and Power ISA v.2.05 with many advanced features such as VMX, virtualization, variable length encoding, hyper visor functionality, logical partitioning, virtual page handling, Decimal Floating point and so on which further boosted the architecture leadership in the market place and POWER5+, Cell, POWER6, PA6T, Titan are various compliant cores.
    [Show full text]
  • Upgrade to POWER9 Planning Checklist
    Achieve your full business potential with IBM POWER9 Future-forward infrastructure designed to crush data-intensive workloads Upgrade to POWER9 Planning Checklist Using this checklist will help to ensure that your infrastructure strategy is aligned to your needs, avoiding potential cost overruns or capability shortfalls. 1 Determine current and future capacity 5 Identify all dependencies for major database requirements. Bring your team together, platforms, including Oracle, DB2, SAP HANA, assess your current application workload and open-source databases like EnterpriseDB, requirements and three- to five-year MongoDB, neo4j, and Redis. You’re likely outlook. You’ll then have a good picture running major databases on the Power of when and where application growth Systems platform; co-locating your current will take place, enabling you to secure servers may be a way to reduce expenditure capacity at the appropriate time on an and increase flexibility. as-needed basis. 6 Understand current and future data center 2 Assess operational efficiencies and identify environmental requirements. You may be opportunities to improve service levels unnecessarily overspending on power, while decreasing exposure to security and cooling and space. Savings here will help your compliancy issues/problems. With new organization avoid costs associated with data technologies that allow you to easily adjust center expansion. capacity, you will be in a much better position to lower costs, improve service Identify the requirements of your strategy for levels, and increase efficiency. 7 on- and off-premises cloud infrastructure. As you move to the cloud, ensure you 3 Create a detailed inventory of servers have a strong strategy to determine which across your entire IT infrastructure.
    [Show full text]
  • IBM POWER8 High-Performance Computing Guide: IBM Power System S822LC (8335-GTB) Edition
    Front cover IBM POWER8 High-Performance Computing Guide IBM Power System S822LC (8335-GTB) Edition Dino Quintero Joseph Apuzzo John Dunham Mauricio Faria de Oliveira Markus Hilger Desnes Augusto Nunes Rosario Wainer dos Santos Moschetta Alexander Pozdneev Redbooks International Technical Support Organization IBM POWER8 High-Performance Computing Guide: IBM Power System S822LC (8335-GTB) Edition May 2017 SG24-8371-00 Note: Before using this information and the product it supports, read the information in “Notices” on page ix. First Edition (May 2017) This edition applies to: IBM Platform LSF Standard 10.1.0.1 IBM XL Fortran v15.1.4 and v15.1.5 compilers IBM XLC/C++ v13.1.2 and v13.1.5 compilers IBM PE Developer Edition version 2.3 Red Hat Enterprise Linux (RHEL) 7.2 and 7.3 in little-endian mode © Copyright International Business Machines Corporation 2017. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . ix Trademarks . .x Preface . xi Authors. xi Now you can become a published author, too! . xiii Comments welcome. xiv Stay connected to IBM Redbooks . xiv Chapter 1. IBM Power System S822LC for HPC server overview . 1 1.1 IBM Power System S822LC for HPC server. 2 1.1.1 IBM POWER8 processor . 3 1.1.2 NVLink . 4 1.2 HPC system hardware components . 5 1.2.1 Login nodes . 6 1.2.2 Management nodes . 6 1.2.3 Compute nodes. 7 1.2.4 Compute racks . 7 1.2.5 High-performance interconnect.
    [Show full text]